Sie sind auf Seite 1von 1

Test protocol DSCS

winch 1 Drum 1 winch 1 Drum 2 winch 2 Drum 1


Item to be tested conditions reason approved declined approved declined approved declined remarks

1 Brake control (rotary knob) 10T top layer to 2nd layer asses brake functionality
2 Hauling (Low Speed/Pulling mode) 2nd layer T max. load (see winch calc.) asses hydraulic pressure and winch clutch functionality (slip @ overload)
3 Hauling (Low Speed/Pulling mode) 2nd layer T max. load (see winch calc.) asses winch speed (see winch calc. for required speed)
4 Veering (Low Speed/Pulling mode) 2nd layer T max. load (see winch calc.) asses winch speed (see winch calc. for required speed)
5 Hauling (High Speed/Slack rope mode) 2nd layer slack wire asses winch speed (see winch calc. for required speed)
6 Veering (High Speed/Slack rope mode) 2nd layer slack wire asses winch speed (see winch calc. for required speed)
7 Hauling (High Speed/Slack rope mode) 2nd layer slack wire ->> increase load asses automatic changeover High ->> low speed
8 Emergency stop 3rd layer 10T during hauling asses functionality (check pumps stopped)
9 Quick release winch brake 3rd layer 10T during emergency stop (3 times required) asses functionality (adjust anti spin pressure on brake)

FLC trails
10 Outstanding wire length 100 meters of outstanding wire asses counting system functionality and layer counting
11 FLC 15T asses functionality and set FLC parameters (check layer on screen and adjust when needed)
12 FLC 25T asses functionality and set FLC parameters (check layer on screen and adjust when needed)
13 FLC 35T asses functionality and set FLC parameters (check layer on screen and adjust when needed)
14 FLC 45T asses functionality and set FLC parameters (check layer on screen and adjust when needed)
15 FLC 55T asses functionality and set FLC parameters (check layer on screen and adjust when needed)
16 FLC 65T asses functionality and set FLC parameters (check layer on screen and adjust when needed)
17 FLC 75T asses functionality and set FLC parameters (check layer on screen and adjust when needed)

18 demonstration deck control 10T asses functionality


19 demonstration foot control 10T asses functionality
20 Brake holding force last layer @ full power asses brake ability to hold load
21 Anchor speed at anchor location asses anchor speed (max 3 minutes for 1 shackle)

Das könnte Ihnen auch gefallen