Sie sind auf Seite 1von 4

2.1.1.

Longitudinal Stress developed due pipe displacement restrain by stiffeners


If the stiffeners are added in pipe, then the local stress at pipe shell developed due to stiffeners
rings are calculates as

ts h s
f s=1.82 *Hoop Stress
As
ts

hs

t
ts + 1.56sqtr(rmt)

Figure 1: Stiffener Ring on Penstock Shell

Where,
fs = longitudinal stress in MPa
As=tshs+t(1.56sqrt(Rmt)+ts)
Rm = Mean Radius of Pipe
t = Penstock Shell Thickness

This stress can be generated in the pipe supports and mid span of pipe is there is stiffeners
present in bends and pipe straight portion.
1. Design Data

Under Sluice Gate


- Type Vertical lift slide
- Opening dimensioning (w x h) 2.0 m x 2.5 m
- Number of
Gates (set) Two (2)
Fixed parts (set) Two (2)
- Elevation of
Sill beam (m.a.s.l) 633.5
Design Water Level (m.a.s.l.) 642.80
Design Head (m) 9.3
Operating platform (m.a.s.l) 644.0
- Operating system Electrical power screw with manual
operation provision
- Operating speed 0.3 m/min
- Operating condition Unbalance pressure
- Sealing type UHMW bumper on ST-ST
- Corrosion allowance 2 mm
- Allowable stresses Acc. to DIN 19704 or equivalent

Intake Gate
- Type Vertical lift slide
- Opening dimensioning (w x h) 2.3 m x 2.0 m
- Number of
Gates (set) Three (3)
Fixed parts (set) Three (3)
- Elevation of
Sill beam (m.a.s.l) 635.5.0
Design Water Level (m.a.s.l.) 642.80
Design Head (m) 7.3
Operating platform (m.a.s.l) 644.0
- Maximum flow rate (m3/sec) 10.92
- Operating system screw spindle
- Operating speed 0.3 m/min
- Operating condition Unbalance pressure
- Sealing type UHMW bumper on ST-ST
- Corrosion allowance 2 mm
- Allowable stresses Acc. to DIN 19704 or equivalent
Trash Passage Gate
- Type Vertical lift slide
- Opening dimensioning (w x h) 1.0 m x 2.5 m
- Number of
Gates (set) One (1)
Fixed parts (set) One (1)
- Elevation of
Sill beam (m.a.s.l) 637.75
Design Water Level (m.a.s.l.) 642.80
Design Head (m) 5.05
Operating platform (m.a.s.l) (644.00)
- Operating system Screw spindle
- Operating condition Unbalance pressure
- Sealing type UHMW bumper on ST-ST
- Corrosion allowance 2 mm
- Allowable stresses Acc. to DIN 19704 or equivalent

Gravel Trap Flushing Gate


- Type Vertical lift slide
- Opening dimensioning (w x h) 1.2 m x 1.2 m
- Number of
Gates (set) Two (2)
Fixed parts (set) Two (2)
- Elevation of
Sill beam (m.a.s.l) 634.3
Design Water Level (m.a.s.l.) (639.35)
Design Head (m) 5.95
Operating platform (m.a.s.l) 640.25
- Operating system Manual screw spindle
- Operating condition Unbalance pressure
- Sealing type UHMW bumper on ST-ST
- Corrosion allowance 2 mm
- Allowable stresses Acc. to DIN 19704 or equivalent

Settling Basin Inlet Gate


- Type Vertical lift slide
- Opening dimensioning (w x h) 2.0 m x 2.0 m
- Number of
Gates (set) Two (2)
Fixed parts (set) Two (2)
- Elevation of
Sill beam (m.a.s.l) 635.86
Design Water Level (m.a.s.l.) 637.96
Design Head (m) 2.1
Operating platform (m.a.s.l) 640.16
- Operating system Manual screw spindle
- Operating condition Unbalance pressure
- Sealing type UHMW bumper on ST-ST
- Corrosion allowance 2 mm
- Allowable stresses Acc. to DIN 19704 or equivalent