YELLOW JACKET AUTOMOTIVE A/C

RECHARGE
andRECHARGE
RECOVERY
RECOVERY

Now Available
SAE J2788 Compliant Series
Coolant Systems
Coolant Systems

first to receive etl approval


Vacuum Pumps
Pumps
and gauges
Vacuum
Detectors
Detectors
Leakage
Leak
Electronic Tools
Electronic Tools
manifolds
manifolds
and hoses
hoses
adaptors and
adapters
fittings
fittings

Refrigerant Management
System 37880
The YELLOW JACKET® Refrigerant Management System
System tools
System tools

(RMS) is the simplest, easiest-to-use A/C service center


helping technicians meet today’s tough service standards.
The RMS 37880 Automatic provides full cycle recovery/
recycle/evacuate/recharge to bring the vehicle back to
factory specifications with the press of one button. Plus,
it's fully compliant with SAE J2788 requirements.

4
EDITION 57 CATALOG

and
RECHARGE
RECOVERY
RECHARGE
RECOVERY
RECHARGE
RMS 37880 Capabilities: RMS 37880 Features:

• Built-in oil injection • Performs SAE J2788 service


• 50-pound storage tank – 20 pounds greater than

Coolant Systems
Coolant Systems
• High or low side charging
• Fully automatic air purging to constantly monitor and most competitive units
purge non-condensables • 10' premium YELLOW JACKET Plus II ™ hoses
• Fast tank refills with no hose changes for easy connection to even hard-to-reach fittings.
• Automatic tank conditioning to ensure a proper Approved SAE J2196
charge every time with no need to start the vehicle • 3.5" color-coded gauges with follower needles,
during charging easy-to-read even inside the vehicle
• Refrigerant management system that keeps track of • High-impact plastic cabinet with rounded corners

Vacuum Pumps
Vacuum
information on A/C service work and edges helps prevent damage to vehicles

and Gauges
• Built-in self-diagnostics • Large pneumatic tires for easy mobility
• Maintenance reminders for oil and filter changes • Built-in accessory tray
• Full factory tested after a 34-point quality check

Pumps
• An LCD alerts technicians to change vacuum pump
oil and filters • Free training, setup and lifetime technical support
• Automatic scale calibration to +/- 0.25 oz. exceeds • One-year parts and labor warranty
industry specifications and results in accurate • Optional integrated refrigerant identifier
and printer

Leak
charging every time

Detectors
Single-pass filtering system

Leakage
Detectors
• Automatic shut-off for full tank and high pressure
• Heavy-duty shock-resistant scale for accurate charging
• Two-stage, 3 or 5 CFM vacuum pump for fast, Specifications:
high-efficiency evacuation Recovery tank 50 lbs.
Dimensions 19.5"W x 29"D x 45"H

Electronic Tools
Electronic Tools
UPC No. Description: Weight 219 lbs.
37880 Automatic RMS with 10' hoses and 3 CFM vacuum pump Compressor 1/2 hp hermetic
37881 Deluxe with printer, identifier and 3 CFM vacuum pump Vacuum pump 2-stage 3 CFM
37882 HD 15' hoses and 5 CFM vacuum pump Hoses 10'
37885 Basic 10' hoses and 3 CFM vacuum pump – 230V Air purge Automatic
37886 HD 15' hoses and 5 CFM vacuum pump – 230V Hour meter Yes

manifolds
manifolds
and hoses
hoses
fittings
adaptors
adapters
fittings
and
System tools
System tools

5
YELLOW JACKET AUTOMOTIVE A/C
RECHARGE
andRECHARGE
RECOVERY
RECOVERY

RecoverX Refrigerant
Recovery Machines
cost-effective alternative to big systems
Coolant Systems
Coolant Systems

Lightweight, low cost, easy-to-use and maintain.

RecoverX refrigerant recovery Machine Features:


• CPR valve regulates refrigerant to the compressor,
eliminating the need for the technician to throttle the
suction valve
Vacuum Pumps
Pumps
and gauges

• Whisper-quiet 1/6 hp oil-filled reciprocating


hermetic compressor
Vacuum

• Oil drain port for easy compressor maintenance


• Oil separator drain
• Automatic safety overfill shut-off sensor cord shuts unit
down after tank reaches 80 percent capacity
• 30-lb. tank with liquid level sensor on some models Applications:
Detectors

• High and low pressure switch with automatic reset


Detectors

• Small shops/low volume


Leakage

• Status LEDs
• Back up systems
– High Pressure
• Off-road and agricultural equipment
– Tank Full
Leak

– System On/Vacuum Complete

Specifications:
Electronic Tools
Electronic Tools

UPC No. Description: Recovery capabilities Vapor and push/pull


39784 RecoverX MR134a recovery unit with 30 lb. cylinder and hose Compressor 1/6 hp oil filled hermetic
39785 RecoverX MR134a basic recovery unit for R-134a Weight 29 lbs.
Dimensions 12.4"W x 19.3"L x 12.5"H

REFRIGERANT GAS ANALYZER Specifications:


Weight 8 lbs.
manifolds
manifolds
and hoses

This portable unit delivers


hoses

Power requirements 12 VDC, via battery clips


the features and benefits (optional power supply available)
professional A/C technicians Output Digital display and LEDs,
want for assurance, ease Optional printer module (internal)
and profitability. Unit comes Refrigerant R-12, R-22, R-134a, HC, and EPA
in a rugged portable case S.N.A.P. approved blends
with R-12 and R-134a Display 128 x 64 pixel graphing
adaptors and
adapters

sample hoses. Resolution 0.1%


fittings
fittings

Operating humidity 0-95% RH non-condensing


Operating temperature 40° to 130°F
refrigerant gas analyzer Features: Start to finish 60 seconds
• Dispersive infrared (NDIR) technology quickly
determines the percentages of R-12, R-134a, R-22,
System tools
System tools

hydrocarbons and air UPC No. Description:


• Analytical software identifies R-12, R-22 and R-134a 68945 Refrigerant analyzer
refrigerants, as well as illegal replacements and
68947 Refrigerant analyzer with printer
blends including propane and butane
68948 Optional internal rechargeable battery kit with
• Quickly and automatically determines purity of R-12 battery and 110 VAC charger
and R-134a to help eliminate potential of human error
68949 Optional 110/220 VAC power adapter
• Large graphing display is easy to read
• Rechargeable battery lasts all day
6
EDITION 57 CATALOG

and
RECHARGE
RECOVERY
RECOVERY
RECHARGE
Refrigerant Recovery Cylinders SERVICE CENTER A/C SET UP
These 30 and 50 lb. The optimum combination of equipment, tools and parts for
400 psi cylinders feature setting up for A/C repair.

Coolant Systems
Coolant Systems
a “Y” valve for liquid/vapor.
Some models feature UPC No. Description:
a float switch with 3/4" 37850 Service center A/C setup includes:
plug. 3-pin Brad Harrison 69365 AccuProbe™ electronic leak detector
connection is standard on 69235 Infrared thermometer
some models; optional 69251 1" dial pocket thermometer
on others.
69742 Mini UV Blue kit

Vacuum Pumps
Vacuum
69092 Heat gun

and Gauges
36780 A/C flush kit
36786 Flush catch hose

Pumps
36770 Universal orifice tube tool kit
36750 Universal A/C compressor clutch kit
UPC No. Lbs: Color: Fitting: Float Switch:
36000 Universal R-12 A/C adapter set
95012 30 lb. yellow/gray 1/4" flare 3
36271 R-134a core remover/installer

Leak
95002 30 lb. yellow/gray 1/4" flare
36270 R-12 core remover/installer

Detectors
95023 30 lb. blue 1/2" ACME 3

Leakage
36400 Universal “O” ring kit

Detectors
95024 30 lb. blue 1/2" ACME
36310 Spring lock coupling – set of 4
95013 50 lb. yellow/gray 1/4" flare 3
36320 Spring lock maintenance kit of “O” rings and springs
95007 50 lb. yellow/gray 1/4" flare
69696 UV spray-off solution
95025 50 lb. blue 1/2" ACME 3
95026 50 lb. blue 1/2" ACME

Electronic Tools
Electronic Tools
UPC No. Description:
95008 “Y” valve for 30 lb. cylinder Wrap-Around Heater for
95011 “Y” valve for 50 lb. cylinder REFRIGERANT CYLINDER 
95009 Liquid level switch for 30 and 50 lb. Worthington and Use to heat 30, 50
Manchester cylinders; 3-pin Brad Harrison connection
and 125 lb. refrigerant
95010 Liquid level switch for 30 and 50 lb. Amtrol cylinders; cylinders. Fits cylinders
3-pin Brad Harrison connection
for most recovery units.
Thermostat controlled.

manifolds
manifolds
and hoses
hoses
THE TRAP™ SEALANT FILTER SYSTEM
This rugged filter cartridge connects
in-line between a vehicle and any
UPC No. Description:
A/C service equipment to protect
68848 Wrap-around cylinder heater 115V
refrigerant supply, recovery system

fittings
68849 Wrap-around cylinder heater 230V
and oil separators. Hi-tech design

adaptors
adapters
fittings
captures large volumes of sealant oil
sludge and other contaminants while
still filtering effectively without plugging. and
Maintenance is fast and simple with a
clean-out drain, and when necessary,
easy filter replacement.
System tools
System tools

UPC No. Description:


38080 The Trap™ sealant filter system, 1/2" ACME fittings
38081 The Trap™ replacement filter kit
38087 The TRAP™ sealant filter system, 1/4" flare fittings
01152 30" R-134a blue hose, 1/2" ACME x 1/2" ACME
45° ball valve end
01153 30" R-134a red hose, 1/2" ACME x 1/2" ACME
45° ball valve end 7