NOTES

· This drawing must be read and in conjunction with appropriate

FLOOR PLAN ·
building standards, and other drawings of the same project.
All dimensions should be checked on site before commencement

x SECTION X-X ·
of works; discrepancies MUST be reported to the architect.
All dimensions are in millimeters, written dimensions are
preferred to scaled dimensions.
· All waste pipes and soil pipes are to be in ducts and the bends to
3990 3450 1650 3790
have cleaning eyes accessible from outside.
· All door frames to be rebated, molded and to be full width of wall
1165 1500 3050 2550 2700 with molded architrave to detail, provide rubber stops to all doors.
· All windows and external glazed doors shall have burglar
proofing to engineers detail.
800 W1 W1 W2 W1
· Internal plaster to be two coats steel float finished.
D2 · All man holes within the building area, drive way and parking to
have heavy duty air tight covers and double sealed.
1075 W/C
· All painting to be 3 coats.
1897
2690
· samples of fittings, materials, etc to be produced and approved
28°
KITCHEN BEDROOM BEDROOM before commencing work.
D1 3490
· The architect shall not accept any liability for works for which he
5450
has not expressly stated, or has accepted to supervise, or for any

CLEAR SPACE
D1 D1 omissions or deviations from his drawings/technical specification,
D1 R871
nor shall he take responsibility for works handled by other
2916 2803 nominated consultants/ contractors.
875 · For clarity other notes are embedded next to the particular
W/C
D1 drawing.
1750 W4
1740
GARAGE LIVING ROOM
D1
MASTER 4390
6620 BEDROOM

WALLING NOTES SUB-STRUCTURE NOTES ROOF NOTES


W3 W1 · Walls are to consist of · Depth of strip to be determined · Grade 28 Eco tiles to be used
D3
masonry. on site. · 150x50 Principal treated rafters at a spacing
· Exterior walls are to be 230mm · incase of depth more than of not more than1800 C/C
800
thick, interior walls are to be 1500mm, a suitable ground · 100x50 purlins
130mm thick. beam shall be used. · 100x50 Struts and ties
2200
D4 VERANDAH · Mortar joints should be no · Stepped foundations are to be · 230x38 ridge boards
400
greater than 13mm. constructed in accordance with · 150x50 wall plate
· Type 2 mortar to be used for standard building practice. · 200x25 fascia boards
walling with well burnt clay · Strip to consist of mass · NB: All timber is to be treated
bricks. concrete, C15
400
1005 · 150mm floor slab to be laid on;
5175 1935
· compacted backfill
· 150 hard core filling revision date notes drawn
3480 5800 3525 · 50mm sand blinding
· damp proof membrane
2990 6100 3790
· Anti termite is to be used PROPOSED RESIDENTIAL BUILDING OF
· Floor slab is to be finished with
13mm screed
MR OCHEN OCHAMA FRANCIS XAVIER
ON PLOT 5977 BLOCK 101
MISINDYE-SONDE, KYAGGWE-MUKONO
x DISTRICT

WINDOW SCHEDULE DOOR SCHEDULE DRAWN BY DATE


Width: 1,200mm Width: 800mm
Height: 1,200mm 04 piece (s) Height: 2,100mm 06 piece (s)
User ID W1/pvo User ID D1/pvo

ROOF PLAN Material


Width: 600mm
Steel casements

Height: 600mm 01 piece (s)


Material Mahogany

User ID W2/pvo Width: 800mm


Material Steel casements Height: 2,100mm 01 piece (s) APPROVED BY DATE
Width: 2,000mm 01 piece (s) User ID D2/pvo
Height: 1,200mm Material Steel casements
User ID W3/pvo
Material Steel casements
Width: 800mm 01 piece (s) Width: 1,200mm 01 piece (s)
Height: 600mm Height: 2,100mm
User ID W4/pvo User ID D3/pvo
Material Steel casements Material Steel casements

Width: 2,400mm 01 piece (s)


Height: 2,100mm
User ID D4/pvo
Material Steel casements

SOAK PIT

SECTION A-A
SOAK PIT NOTES
· The depth to the inlet shall be
determined on site
· Diameter and depth from the
inlet to the bottom can be
PLAN varied to give the required
Selected compacted fill 300mm thick absorption area depending on
the subsoil water table
· Bottom of the soak pit should
not be less than 600mm into
the subsoil

3500

A A

Ø2700