Beruflich Dokumente
Kultur Dokumente
Maybachstraße 1
D-74653 Künzelsau-Gaisbach
Pers. of Cont.: Razvan Catarama
Date: 5/10/2019 Order -
Project No: RC0481 Pos-No: 1 Ref.:
Customer:
Project:
Supply: Airbox S40-10Q Height: 1880mm Width: 1350mm Weight: 1592kg
Exhaust: Airbox S40-10R AHU-S4010QWW Length: 5130mm S40 - 40mm Insulation
Weather Proof Design
570
330 1530 1290
730
PRALLKTF
A3 A2 A1
1050
KTF SOND-ERH
FSRAZ PRALL
Z1 W1 Z2 Z3 Z4
KTF SOND-ERH
FSRAZ PRALLKTF
PRALL
Z1 A3 Z2
A2 Z3 A1 Z4
W1
Technical Data
Sup Z1 C1 Air damper weatherproof, 800x900
dp Air: 2 Pa
Sup W1 C1 RWT-EA1250x1250-1200V-020
Reference: EA1250x1250-1200V-020-2D0RA-AAPI-A&1302
Wheel Type: Kondensation (Alu) Construction: one piece
Temp outside Air: -21 °C Temp. Exhaust: 23 °C
Humidity outside Air: 90 %r.F. Humidity Exhaust: 60 %r.F.
Temp. Supply: 10.4 °C Temp out Exhaust: -3 °C
Humidity Supply: 86 %r.F. Humidity out Exhaust: 59.1 %r.F.
dP Supply: 135 Pa dP Exhaust: 134 Pa
Recovery Factor: 71.3 %
Total Power: 93.3 kW Temp. Übertragungsgrad tr.: 73.7 %
Sensible Power: 62.7 kW Humidity Efficiency: 61.9 %
Latent Power: 30.5 kW
Leakage: Quantity and direction depending on fan configuration and possible used irrigation chamber
Please consider the leakage in the design
Aufgen. Leistung Motor: 0.07 kW Coefficient of Performance: 38.6
Efficiency-Class: 71.8 % Heat Recovery Class: H1
Power Cons. Due to dp: 0.705 kW
Code: 7NHB0952091520507960864061027125125CEE4015
Fan designed for pressure drop of wet conditions
Supply Exhaust
Air volume: 1.65 m³/s Air volume: 1.65 m³/s
Δpsext: 450 Pa Δpsext: 350 Pa
Input Power: 2.46 kW Input Power: 2.3 kW
Δpsint: 130 Pa Δpsint: 202 Pa
Δpsadd: 331 Pa Δpsadd: 156 Pa
Velocity: 1.7 m/s Velocity: 2.6 m/s
ηstat(327/2011/EU): / Eff. Grade N 61.1 % / 77 % ηstat(327/2011/EU): / Eff. Grade N 66.9 %
Filter: M5 Filter: M5
Sound power level: 55 dB(A) Sound power level: 60 dB(A)
General:
Filter warning: To fulfil the regulation 1253/2014/EU the installed filters need to be equipped with
a visual signal or an alarm in the control system which shall be activated as soon
as the filter pressure drop exceeds the maximum final pressure drop.
Thermal bypass: The thermal bypass can be realized by a stoppage of the rotary heat exchanger.
Drive: If the ventilation unit is ordered and delivered without multi-speed drive or variable
speed drive, it has to be provided with it to fulfil regulation 1253/2014/EU.
Delivery Condition
Payment Conditions
Delivery Time
570
330 1530 1290
730
PRALLKTF
A3 A2 A1
1050
KTF SOND-ERH
FSRAZ PRALL
Z1 W1 Z2 Z3 Z4
KTF SOND-ERH
FSRAZ PRALLKTF
PRALL
Z1 A3 Z2
A2 Z3 A1 Z4
W1
Technical Data
Sup W1 C1 RWT-EA1250x1250-1200V-020
Reference: EA1250x1250-1200V-020-2D0RA-AAPI-A
Wheel Type: Kondensation (Alu) Construction: one piece
Temp outside Air: 32.8 °C Temp. Exhaust: 25 °C
Humidity outside Air: 35 %r.F. Humidity Exhaust: 55 %r.F.
Temp. Supply: 27 °C Temp out Exhaust: 30.8 °C
Humidity Supply: 48.9 %r.F. Humidity out Exhaust: 39.2 %r.F.
dP Supply: 137 Pa dP Exhaust: 137 Pa
Recovery Factor: 74.5 %
Total Power: 11.8 kW Temp. Übertragungsgrad tr.: 73.8 %
Sensible Power: 11.8 kW Humidity Efficiency: 0%
Latent Power: 0 kW
Leakage: Quantity and direction depending on fan configuration and possible used irrigation chamber
Please consider the leakage in the design
Aufgen. Leistung Motor: 0.07 kW Coefficient of Performance: 38.6
Efficiency-Class: 71.9 % Heat Recovery Class: H1
Power Cons. Due to dp: 0.705 kW