Sie sind auf Seite 1von 2

BIRLIK MAKINA ALF 330-O

Section C: INSTALLATION…

TRANSPORTATION .
.

Q : 820 Kg.

C
A

Minimum room space and gap dimensions are


D
given below:

Minimum Room Space:

B A: 2150 mm.
B: 1100 mm.

Gap Dimensions:

As for transportation, four hooks labeled A, B, C A1: 500 mm.


and D are shown on the above figure. A2: 500 mm.
B1: 5000 mm.
Connect the crane hook to the transportation B2: 3000 mm.
hooks with a heavy-duty fiber belt and move the
machine to a proper workplace in your plant away During unpacking, do not damage the machine!
from sun, dust and wet environments.

Position the band saw machine


Caution in your plant such as to secure
! the personnel, machine and the
environment during transportation, operation and
driving work piece.

Never walk under suspended


loads! Check that the lifting
equipment and load limiters are

! sufficient load capacity and are in


perfect condition! Hold the loads
properly! Observe the general
transportation and security rules!

POWER UP .
MOUNTING .
7
BIRLIK MAKINA ALF 330-O

Section C: INSTALLATION…

START UP .
Disconnect machine from power .
! source before wiring, and be sure that
machine is properly grounded!
All accurate regulations are performed by our
expertised personnel during final control. Electrical
power connections are to be performed as
Connect the R, S, T phases to L1, L2, L3 terminals explained in the previous item. Beside these,
and neuter to N terminal PE earth terminal using please check the following functions.
5x2.5mm2 cable. 15
13 14
set

Wire the earth connection of the


Caution plant to the grounding terminal
! of the electrical panel. G

Connect machine to the power source after 1 12


9 10 11 5
ensuring all safety regulations. Turn on the main START

switch on the electrical panel cover.


4
15
13 14 2 3 7 8 6
set
STOP

Fill a suitable cooling agent of 21.46 litres –water- GETK.8042.001

soluble and non-pollutant where available- into the


G machine casing. In the manual mode, turn the
1 12
9 10 11 5 cooling button (6) to right. Check whether the
START
cooling agent is fed thru the cooling agent taps.
Then turn button (6) to left and disconnect agent
2 3 4
7 8 6 flow.
STOP

GETK.8042.001

Press saw arch up button (7) and raise the saw


arch up to the top limit. At the top level, turn the
Counter (13) and inverter (12) control panel will be throttle valve (10) clockwise to its limit. Press start
energized. button (1). Check that the direction of the saw,
when observed front view, is leftwards. Press stop
Turn the mode selector (3) to right and select button (2) to stop the machine.
manual mode.
For failures during tests, please see Operational
Press Saw Arch Up Button (7). Failures, Possible Causes & Remedies in the
Annexes.
If it functions, the connections are valid. Otherwise,
phases are misconnected.

Disconnect machine from the power source and


interchange the cable ends on the terminals L1
and L2.