18. Can you able to start the GT unit, without switch on the power supply to the emergency oil
pump?
19. What will you do, if 'fire' alarm came by device malfunction?
20. What is frequency?
21. At what frequency incoming feeder will trip?
22.How the turbine air filters suck the air?
23. What is the meaning of purge air?
. .
24. At what state vibration alarm will come?
25.If spread #1 increased more than allowable-spread; what will happen?
26.When will you get gas fuel pressure low alarm?
27. During G.T running, if anyone turbine cooling fan (TK) is trip, what will you do? Will it trip the
unit?
28. If load increase, power factor?
29. At what temp. Gen. Tx cooling fan will run?
30. G.T unit will trip at header pressure 0.78 bar, but emergency pump will start at 0.4 bar, why?
31. During starting when will 88QA start & stop?
@ If you give rise command, load will increase but speed will remain constant why? How the heat
energy converted into load?
DATE: 01.01.11
THERE IS GOOD IN EVERY EVENT
1. It is impractical to measure combustion chamber temperature and to avoid the thermal stress on
turbine parts by regulating the fuel flow.
2. 0,78 bar
3. A7
4. Speed control can increase the load but temperature control will maintain the load.
5. 17 stages & axial- flow compressor
6. 95%
7. 95°C
8. By rotor fans
9. By decrease the load
10.To reduce the speed to 3000 rpm & to achieve the frequency (50HZ).
11.When G.T is running on liquid fuel, to convert the droplet into tiny (small) particles in fuel
nozzle for attain good combustion.
th
12. 5 stage
13. Select "Isoch" mode.
14.79 deg. C
15. Can see the process parameters (flame condition, fuel flow ... ) and Very compact.
16. 49° C
17. To take/give O/P or I/P in the rotating element.
18. No, it cause pre-ignition trip.
19.Confirm from which zone alarm is coming (see the LED) then press 'Isolate' push button on the
fire protection panel.
20. How many cycles are taken in one second i.e. frequency. (No of cycle I second).
21. 49.3 Hz
22. By main compressor blades.
23.When GT is running on gas fuel, liquid fuel nozzle may get rust and dust; to avoid this
pressurized air was applied on liquid fuel nozzle.
24. 12.7 mm /sec.
25. "Combustion trouble" alarm will come.
26. Gas pressure come down to 16 bar.
27. Reduce the load. It won't trip the GT immediately.
28. Increase
29. 85° C
30. To maintain the lubrication of the bearings.
31. Start after gave start command, stop at 95% speed.
32. No, "flame detector trouble' alarm will come.
33. Voltage, Frequency, Phase
34. Fuel pressure, IGV position, Zero speed, Communication between processor, Lube oil tank
temperature normal (> 15°C), Flame detector, servo coil & vibration sensor are ok (these are
tested by feedback test), Generator breaker in open.
35. During trip shutdown, gas supply will immediately cut off and cause the trip by loss of
flame. During fired shutdown speed will slowly reduce, flame cutoff after speed reach 1500
rpm.
36. 50 Psi (3.45 bar)
37. Emergency motor in 'auto' mode, Calibration mode disable, Minimum CPD pressure
(>2Psi).
38. It won't stop automatically, by manual select 'off cool down'.
39. 1.65 bar
40. After the 'fire' command.
41. No, it is prevented by current saturation test.
42. Each section had two sensors, if one in trip level another in alarm level
43. Lube oil vapor is having oil, for getting oil back. It'll allow vapor pass through the filter.
Mist eliminator will start after the 'start' command.
44. FSG- Feedback gas control valve position, FAG - Feedback gas control valve servo current.
45. Isolate the air supply to pulse cleaning system
DATE: 01.01.11