Site 1 / Building 1 / Storey 1 / Ligman Lighting Co.,Ltd. SI-80021-M-40 Sidney 2 recessed no glare downlight luminaire 7 LED 1x7
LED 4000K / Ligman Lighting Co.,Ltd. - Sidney 2 recessed no glare downlight luminaire 7 LED (1x7 LED 4000K)

Ligman Lighting Co.,Ltd. SI-80021-M-40 Sidney 2 recessed no glare downlight


luminaire 7 LED 1x7 LED 4000K

See our luminaire


catalog for an image of
the luminaire.

Absolute photometry
Luminaire luminous flux: 755 lm
Power: 11.8 W
Luminous efficacy: 64.0 lm/W

Colorimetric data
1x: CCT 3000 K, CRI 100

Luminous emittance 1 / Polar LDC


105° 105°

90° 90°

75° 75°

60° 60°

800

45° 45°
1200

1600

30° 15° 0° 15° 30°

cd 755 lm
C0 - C180 C90 - C270

Page 1
Project 0 09/12/2018

Site 1 / Building 1 / Storey 1 / Ligman Lighting Co.,Ltd. SI-80021-M-40 Sidney 2 recessed no glare downlight luminaire 7 LED 1x7
LED 4000K / Ligman Lighting Co.,Ltd. - Sidney 2 recessed no glare downlight luminaire 7 LED (1x7 LED 4000K)

Luminous emittance 1 / Linear LDC


1750

1500

1250

1000

750

500

250

90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0°


cd 755 lm
C0 - C180 C90 - C270

Luminous emittance 1 / Cone diagram

E(0°) 6799
0.50 0.29 E(C0) 16.4° 3008

E(0°) 1700
1.0 0.59 E(C0) 16.4° 752

E(0°) 755
1.5 0.88 E(C0) 16.4° 334

E(0°) 425
2.0 1.2 E(C0) 16.4° 188

E(0°) 272
2.5 1.5 E(C0) 16.4° 120

E(0°) 189
3.0 1.8 E(C0) 16.4° 84

Distance [m] Cone diameter [m] Illuminance [lx]


C0 - C180 (Beam angle: 32.8°)

Page 2
Project 0 09/12/2018

Site 1 / Building 1 / Storey 1 / Ligman Lighting Co.,Ltd. SI-80021-M-40 Sidney 2 recessed no glare downlight luminaire 7 LED 1x7
LED 4000K / Ligman Lighting Co.,Ltd. - Sidney 2 recessed no glare downlight luminaire 7 LED (1x7 LED 4000K)

Luminous emittance 1 / Luminance diagram


C225 C180 C135

C270 C90

800

1200

1600

2000
C315 C0 C45

cd/m²
g = 65.0° g = 75.0° g = 85.0°

Luminous emittance 1 / UGR diagram


Glare evaluation according to UGR
ρ Ceiling 70 70 50 50 30 70 70 50 50 30
ρ Walls 50 30 50 30 30 50 30 50 30 30
ρ Floor 20 20 20 20 20 20 20 20 20 20
Room size Viewing direction at right angles Viewing direction parallel
X Y to lamp axis to lamp axis
2H 2H 14.7 15.5 15.0 15.7 15.9 14.7 15.5 15.0 15.7 15.9
3H 14.6 15.3 14.9 15.5 15.8 14.6 15.3 14.9 15.5 15.8
4H 14.6 15.2 14.9 15.5 15.7 14.6 15.2 14.9 15.5 15.7
6H 14.5 15.1 14.8 15.4 15.6 14.5 15.1 14.8 15.4 15.6
8H 14.5 15.0 14.8 15.3 15.6 14.5 15.0 14.8 15.3 15.6
12H 14.4 14.9 14.8 15.3 15.6 14.4 14.9 14.8 15.3 15.6
4H 2H 14.7 15.3 15.0 15.6 15.8 14.7 15.3 15.0 15.6 15.8
3H 14.6 15.1 15.0 15.4 15.7 14.6 15.1 15.0 15.4 15.7
4H 14.5 15.0 14.9 15.3 15.7 14.5 15.0 14.9 15.3 15.7
6H 14.5 14.8 14.9 15.2 15.6 14.5 14.8 14.9 15.2 15.6
8H 14.4 14.8 14.8 15.1 15.5 14.4 14.8 14.8 15.1 15.5
12H 14.4 14.7 14.8 15.1 15.5 14.4 14.7 14.8 15.1 15.5
8H 4H 14.4 14.8 14.8 15.1 15.5 14.4 14.8 14.8 15.1 15.5
6H 14.3 14.6 14.8 15.0 15.5 14.3 14.6 14.8 15.0 15.5
8H 14.3 14.5 14.8 14.9 15.4 14.3 14.5 14.8 14.9 15.4
12H 14.2 14.4 14.7 14.9 15.4 14.2 14.4 14.7 14.9 15.4
12H 4H 14.4 14.7 14.8 15.1 15.5 14.4 14.7 14.8 15.1 15.5
6H 14.3 14.5 14.8 14.9 15.4 14.3 14.5 14.8 14.9 15.4
8H 14.2 14.4 14.7 14.9 15.4 14.2 14.4 14.7 14.9 15.4
Variation of the observer position for the luminaire distances S
S = 1.0H +2.3 / -3.4 +2.3 / -3.4
S = 1.5H +4.4 / -5.2 +4.4 / -5.2
S = 2.0H +6.3 / -13.5 +6.3 / -13.5

Standard table BK00 BK00

Correction Summand -3.8 -3.8

Corrected glare indices referring to 755lm Total luminous flux

The UGR values are calculated in acc. with CIE Publ. 117. Spacing-
to-height ratio = 0.25