Specifications Unit Description Serial Interface


10 inch Panel PC General specifications ① ② All devices which are connectable with APC-1011 including PC, PLC, serial printer, barcode

APC-1011 Model
Power supply
APC-1011
24VDC
reader, and dedicated connectors can be connected to any of RS232C, RS485 and RS422
ports.
Changing serial interface
INSTRUCTION MANUAL Allowable voltage
range
90 to 110% of power supply 1) Open the rear case of APC-1011 with a screw driver.
2) S et the serial interface selecting jumper pin (①) with the jumper bar to serial interface to use.
Power consumption Max. 30W 3) When setting to RS232C, connect the D-sub connector to COM2 (②).
When setting to RS485/RS422, connect the D-sub connector to JP12 (③).
Hard disk mSATA 64GB SSD
※For more details, refer to the below image and table.
System memory DDR3L 4GB
Indicator Power indicator: green LED
Speaker Stereo speaker 2W+2W
Watch dog timer Watch Dog Timer (1 to 255 sec, software setting) ① ③ ②
<Inside of APC-1011>
Battery life cycle 5 years at 25℃ No. Description
Real-time controller RTC embedded No. Name RS232C (default) RS485 RS422
Operation indicator
Insulated resistance Min. 100MΩ (at 500VDC megger) ① 2 4 6 8 10 12 2 4 6 8 10 12 2 4 6 8 10 12
(green LED)
Serial interface
Ground 3rd grounding (max. 100Ω) ② LCD screen ①
setting jumper pin
Noise immunity ±0.5kV the square wave noise (pulse width: 1㎲) by the noise simulator ③ HDMI 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11
Withstanding voltage 500VAC 50/60Hz for 1 minute ④ VGA 2 4 6 8 10
Thank you for choosing our Autonics product.
0.75mm amplitude at frequency of 10 to 55Hz (for 1 minute) ⑭
Please read the following safety considerations before use. Vibra-
Mechanical
in each X, Y, Z direction for 1 hour
⑤ USB 2.0 ② COM2 -
tion 0.5mm amplitude at frequency of 10 to 55Hz (for 1 minute) ⑥ Ethernet 1 3 5 7 9
Malfunction
Safety Considerations in each X, Y, Z direction for 10 minutes ⑦ USB 3.0 2 4 6
Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times ⑧ Audio ③ JP12 -
※Please observe all safety considerations for safe and proper product operation to avoid Shock
hazards. Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction for 3 times RS232C/RS485/RS422
⑨ 1 3 5
※ symbol represents caution due to special circumstances in which hazards may occur. Ambient (jumper pin setting)
0 to 50℃, storage: -20 to 60℃ D-sub connector by type of serial interface
Environ temperature ⑬ ⑩ Power switch
Warning Failure to follow these instructions may result in serious injury or death. ment Ambient
35 to 85%RH, storage: 35 to 85%RH ③ ④ ⑤⑥ ⑦⑧ ⑨ ⑩ ⑪ ⑪ Power terminal Port Pin Port Pin Port Pin
humidity
Caution Failure to follow these instructions may result in personal injury or product damage. Fixing bracket RS232C 1 DCD RS422 1 TXD- RS485 1 DATA-
Language※1 Korean, English ⑫
mounting slot 2 RXD 2 TXD+ 2 DATA+
Warning Protection structure IP65 (front panel, IEC standard)
Mold bracket 1 3 TXD 1
6 3 RXD- 1
6 3 Disabled
Accessory Fixing bracket: 8, mold bracket: 1, M3 bolt for mold bracket: 2 ⑬ 6
1. F ail-safe device must be installed when using the unit with machinery that may cause mounting hole 2
7 4 DTR 2
7 4 RXD+ 2
7 4 Disabled
serious injury or substantial economic loss. (e.g. nuclear power control, medical Approval
⑭ VESA hole 3
8 5 GND 3
8 5 GND 3
8 5 Disabled
equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety Weight※2 Approx. 2kg (approx. 1.6kg) ⑫ 4 4 4
equipment, crime/disaster prevention devices, etc.) 9 6 DSR 9 6 GND 9 6 Disabled
※1: Supported language can be added by downloading language pack. For more details about 5 5 5
Failure to follow this instruction may result in personal injury, economic loss or fire. 7 RTS 7 Disabled 7 Disabled
language pack, please visit Microsoft website.
2. Do not use the unit in the place where flammable/explosive/corrosive gas, high ※2: The weight includes packaging. The weight in parenthesis is for unit only. Dimension D-Sub 9-pin
Female
8 CTS
D-Sub 9-pin
Female
8 Disabled
D-Sub 9-pin
Female
8 Disabled
humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. ※Environment resistance is rated at no freezing or condensation. (unit: mm) 9 RI 9 Disabled 9 Disabled
Failure to follow this instruction may result in explosion or fire. 245
3. Use the unit within the rated specifications. Performance specifications
Failure to follow this instruction may result in fire or shortening the life cycle of the product.
System performance
4. Do not connect, repair, or inspect the unit while connected to a power source. Installation
Failure to follow this instruction may result in fire. CPU Integrated Intel J3160/1.6GHz Quad core processor, TDP 6W
Installing on panel
5. C heck 'Power Wiring' and 'Serial Interface' before wiring. Operating system Windows 10 IoT Enterprise Entry (64bit) 1. Set APC-1011 in panel.
Failure to follow this instruction may result in fire. Display performance 2. Set fixing brackets in slots (3 in top, 2 in bottom, 2 in side).
6. In preparation for product damage, communication error, or malfunction, install LCD type IPS TFT Color LCD 273 3. Tighten fixing brackets with the M4 screw driver with the tightening torque of 0.3 to 0.5Nm.
external limit switch, emergency stop switch, or other protection circuit. 43
Touch method Resistive 100 7
Failure to follow this instruction may result in personal injury, economic loss or fire. 4-M4
7. Since Lithium battery is embedded in the product, do not disassemble or burn the unit. Resolution WXGA 1280×800 M4 screw driver
Failure to follow this instruction may result in fire. Contrast 16:10
8. D o not disassemble or modify the unit. Display area 216.96×135.6mm 4. W
 hen additional fixing bracket is in need on the bottom, connect the mold bracket on the
Failure to follow this instruction may result in fire. Color 16,777,216 color rear of the product, before set fixing bracket. Tighten mold bracket with the M3 screw driver
9. Please contact to us for battery replacement. with the tightening torque of 0.3 to 0.5Nm.
LCD view angle Within 85°of top/bottom/left/right
Caution

100
Backlight White LED

186.6

160
1. U
 se dry cloth to clean the unit, and do not use water or organic solvent. Backlight MTBF 50,000hrs (LED Backlighting)
Failure to follow this instruction may result in electric shock or fire. Luminance 350cd/m2
2. When connecting the power input, use AWG 23 cable or over and tighten the
Interface type
terminal screw with a tightening torque of 0.5 to 0.8N.m. Mold bracket mounting hole
Failure to follow this instruction may result in fire or malfunction due to contact failure. HDMI 1 ※When using the mold bracket, install it with the included bolts (M3×8mm). If you use a bolt
3. Keep the product away from metal chip, dust, and wire residue which flow into the unit. USB USB 3.0 HOST: 1, USB 2.0 HOST: 2 out of the specification, it may result in product damage.
Failure to follow this instruction may result in fire or product damage. VGA 1
Installing with holder
4. Do not push over 2 point at the same time. You have to purchase 100×100mm holder separately. Autonics does not have dedicated holder.
Ethernet Gigabit Ethernet: 2 Fix the purchased holder to the VESA hole on the rear of the product, using M4 Screw driver.
Failure to follow this instruction may result in malfunction. Fixing bracket Mold bracket
Audio 1 Way to fix holder can be different according to each holder.
Serial RS232C/RS422/RS485: 1 (jumper pin setting) 15
Cautions during Use M4
2-R1.5 5 12
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents. 2-Ø3.2
2. 2 4VDC power supply should be insulated and limited voltage/current or Class 2, SELV power Power Wiring 14 VESA
supply device. hole
For power supply, use the wire of which cross section is at least 0.75mm²

4
3. Install a power switch or circuit breaker in the easily accessible place for supplying or

10.4
disconnecting the power. and use the wire of which cross section is at least 1.25mm² for grounding.
4. O perate the product after supplying power to the product, input/output equipment, and load. Use round terminal with at least 3mm of internal diameter and less than 22
6mm of external diameter. 2
If operate product before supplying power, it may result in output error or malfunction. Panel cut out 2-R1.5
5. K eep away from high voltage lines or power lines to prevent inductive noise. Do not apply power before power line connection.
2.4
Do not use near the equipment which generates strong magnetic force or high frequency Check power polarity.

18
noise. Tighten the terminal screw with 0.5 to 0.8N·m torque. Min. 318
6. Make a required space around the unit for radiation of heat, and do not block ventilation
openings.
Ground resistance should be less than 100Ω and ground it separately. 246 +1.1
0.0 Max. 4-R3
3.8 11
Major Products
Photoelectric Sensors Temperature Controllers
7. D
 o not push the touch panel with a hard and sharp object or push the panel with excessive
160 +1.0
0.0

force. Software Installation 15.4 Fiber Optic Sensors Temperature/Humidity Transducers

Min. 232
Door Sensors SSRs/Power Controllers
It may result in fire or malfunction. You can download and use software programs for Autonics products in APC-1011. Door Side Sensors Counters
8. W hen skin is smeared with liquid crystal from the broken LCD, rinse with running water for Please refer to the catalogue or user manual for detailed information about software programs Area Sensors Timers
over 15 minutes. for APC-1011. Proximity Sensors Panel Meters
If it gets into the eyes, rinse eyes with running water for over 15 minutes and contact a doctor. ※Newly purchased APC-1011 has Vision Master program as default. ※Panel thickness : max. 4mm Pressure Sensors Tachometer/Pulse (Rate)Meters
9. W hen system is down, push the power switch for 7 seconds and turn on again for rebooting Rotary Encoders Display Units
the product. Installation Connector/Sockets Sensor Controllers
10. T  his unit may be used in the following environments. Installation using PC Manual Switching Mode Power Supplies
①Indoors (in the environment condition rated in 'Specifications') 1. Download program to install from Autonics website (www.autonics.com). For the detailed information and instructions, please refer to the user manual, and be sure to follow Control Switches/Lamps/Buzzers
②Altitude max. 2,000m 2. Save the downloaded installation file in a USB driver and plug the USB driver to USB port cautions written in the technical descriptions (catalog, website). I/O Terminal Blocks & Cables
③Pollution degree 2 http://www.autonics.com
of APC-1011 to move the installation file. Visit our website (www.autonics.com) to download manuals. Stepper Motors/Drivers/Motion Controllers
④Installation category II 3. Touch the installation file in APC-1011 to install the program. Graphic/Logic Panels HEADQUARTERS:
Field Network Devices 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
Direct installation
※The above specifications are subject to change and some models may be discontinued
without notice. 1. Plug LAN cable to Ethernet port of APC-1011 to connect to Internet. Battery Replacement Laser Marking System (Fiber, Co₂, Nd:yag)
South Korea, 48002
TEL: 82-51-519-3232
Laser Welding/Cutting System E-mail: sales@autonics.com
※Be sure to follow cautions written in the instruction manual, user manual and the technical 2. Access to Autonics website (www.autonics.com) in APC-1011 to download program. Please contact our service center to replace battery.
descriptions (catalog, homepage). 3. Touch the downloaded installation file in APC-1011 to install the program. It may cause an explosion or a fire when using improper battery. DRW180636AD

Das könnte Ihnen auch gefallen