Sie sind auf Seite 1von 2

Amendment No.

1/August, 2013/IRC:112-2011
to
IRC:112-2011 “Code of Practice for Concrete Road Bridges”

S. No. Clause No. For Read


1 Clause 10.1 Add following sub Para:
Page No. 80 For concrete of grades higher than M60,
the shear strength shall be limited to that of

C
strength grade M60 for design purpose.
2 Clause 10.3.1 fywd = Design strength of web reinforcement fywd = Design strength of web reinforcement to
Notation used to resist shear limited to 0.8 fyk/gm. f yk
Page : 86 resist shear =
γm

Page: 87 v1 is a strength reduction factor. v1 = v is a strength reduction factor for concrete


1. Value is given by v1 ≈ v. Where v is cracked in shear, given in Eq. 10.6.
IR
Page: 88
given by Eq. 10.6.

2. If design stress of shear reinforcement is


below 80 percent of fyk value of v1 can be
Delete

taken as :
v1 = 0.6 for fck ≤ 80 MPa

= 0.9 –
f ck > 0.5 for fck > 80 MPa Delete
250

3 10.3.3.2: fywd = Design strength of web reinforcement fywd is the design strength of web reinforcement
Members used to resist shear limited to 0.8 fywk f yk
with vertical to resist shear =
γm
Shear
reinforcement

Page No. 91 v1 is a strength reduction factor for concrete v1 = v is a strength reduction factor for concrete
cracked in shear: cracked in shear given in Eq 10.6.
v1 = 0.6 for fck ≤ 80 MPa Delete
f ck
v1 = 0.9 – > 0.5 for fck > 80 MPa Delete
250
If v1 = v, then value of 0.67 fyk can be used. Delete

INDIAN HIGHWAYS, October 2013 49


Amendment To IRC:112-2011

S. No. Clause No. For Read

4 5.3.2.5 The bridge or any of its components shall The bridge or any of its components shall
Limit State of not loose its capacity to carry design loads not lose its capacity to carry design loads by
Fatigue by virtue of its materials reaching fatigue virtue of its materials reaching fatigue limits
limits due to its loading history. due to its loading history. For carrying out
Page No. 21
Note : For structures designed as per this fatigue verification, specialist literature may
Code, the effects of fatigue due to action of be referred.
live loads on concrete need not be taken into However, fatigue verification is not necessary

C
account, unless otherwise specified. for the following:
a) For Reinforced concrete structures when
the stress in the tensile reinforcement is
less than 300 MPa under Rare Combination
of Serviceability Limit State as against
0.8 fy specified in clause no. 12.2.2.
b) For prestressed concrete structures under
the frequent combination of action and
IR prestressing force, only compressive stresses
occur at the extreme concrete fibers, under
Serviceability Limit State.

S. No. Figure No. & For Read


Page No.
5. Figure 6.1 (b)
(Page 29)

fyk ---

(b) Hot Rolled/Heat Treated HYSD Steel (b) Hot Rolled/Heat Treated HYSD Steel

50 INDIAN HIGHWAYS, October 2013

Das könnte Ihnen auch gefallen