GENERATOR DRIVE - ADJUSTMENT/TEST
1. Generator Constant Speed Drive Adjustment
A. Governor adjustment is accomplished as necessary to provide
generator output frequency of 400 (±4) cps.
NOTE : If filter or magnetic plug show indication of failure or
contamination, or if frequency is unstable or erratic,
or if frequency goes out of limits and stays out upon
application or removal of loads, replace CSD rather than
adjust governor. If filter, magnetic plug, or CSD is
contaminated, also replace oil cooler and associated
tubing.
FED ALL
2. Generator Constant Speed Drive Test
A. Following are two disconnect tests; only one need be performed.
If engines are running, dynamic test the disconnect. If engines
are not running, static test the disconnect.
(1) Dynamic disconnect test.
(a) Start engine and run at idle speed (Ref 71-00 ,
MP).
(b) Set BATTERY switch on P4 upper panel to ON.
(c) Turn ac meters selector switch to GEN 1, GEN 2, or
GEN 3 as applicable.
(d) Check that voltage is indicated on ac voltmeter.
(e) Remove lockwire and raise guard on DISCONNECT
switch on P4 panel and actuate switch.
CAUTION : DO NOT ACTUATE DISCONNECT BELOW MINIMUM
ENGINE IDLE SPEED. DAMAGE MAY OCCUR AS A
RESULT OF INCOMPLETE DISCONNECT.
CAUTION : DO NOT ACTUATE THE DISCONNECT SWITCH FOR
PERIODS LONGER THAN 3 SECONDS. ALLOW A
MINIMUM OF 60 SECONDS BETWEEN ACTUATION
PERIODS. CSD MAY BE DAMAGED.