Base frame (overall length 390 mm)


EM 260/410/510 for video web monitoring

Contents

Description .............................. 1 4. Care and maintenance........... 9

1. Safety................................. 2 4.1 Qualification of staff ........... 9

2. Technical Data ..................... 3 4.2 Care.................................. 9

3. Operation ............................ 4

3.1 Operating elements ............. 4

3.2 Setting up ......................... 5

3.3 Inserting web ..................... 6

3.4 Setting .............................. 7

3.5 Starting up ........................ 7

3.6 Shutting down ................... 7


3.6.1 Shutting down for a short
period ..................................... 7
3.6.2 Shutting down at end of shift .... 7
3.6.3 Shutting down for a longer
period ..................................... 7

3.7 Malfunctioning ................... 8

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 0

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

Description

This base frame BG 55, which has an


overall length of 390 mm is designed for
fitting a video web monitor type
EUROSCOPE made by the BST company.

The upper side or the lower side of the


web can be monitored.

The essential operating elements for the


web monitor are located on the camera
unit.

The synchronization transmitter (proximity


switch) controlling the picture generation
is located at the phase shifter gearbox of
the last base frame BG 10 of your
machine.

The monitor and controller are located on


the drive cover or on the rail system on
the top of the drive cover of the base
frame.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 1

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

1. Safety

Please observe the general safety


instructions at the beginning of this
manual. In addition, please observe the
safety instructions of the manufacturer of
the additional equipment (BST company).

Caution :
Risk of cutting injury through exposed
running edges of web.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 2

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

2. Technical Data

EM 260 EM 410 EM 510


• Web width max. 258 mm 413 mm 516 mm
• Travel max. 245 mm 400 mm 500 mm
(camera unit)

• Dimensions EM 260 EM 410 EM 510


- Length: 390 mm
- Width: 835 mm 990 mm 1090 mm
- Height: 1572 mm
- Weight:

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 3

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

3. Operation

3.1 Operating elements

1 camera unit

2 monitor

3 controller

4 traverse

5 base frame

6 deflection roller

7 rail system

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 4

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

3. Operation

3.2 Setting up

When installing the camera unit, monitor


and controller, please follow the
installation instructions of the
manufacturer of the additional equipment,
BST company (see operating instruction
"Video web monitor system type
EUROSCOPE" of the BST company.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 5

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

3. Operation

3.3 Inserting web

To ensure correct functioning, it is


essential that the run of the web
corresponds to the above sketch.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 6

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

3. Operation

3.4 Setting 3.6.2 Shutting down at end of shift

The settings required for operation of the At the end of the shift, the printing
web monitor system are made at the machine should be switched off (see
operating elements of camera unit 1 (see operating instruction "Drive station BG
operating instruction "Video web monitor 09).
system type EUROSCOP" of the BST In addition, monitor 2 and controller 3
company. should be switched off at the
corresponding mains switch.
3.5 Starting up
At the start of a new shift, controller 3
After all the necessary settings have been and monitor 2 must be switched on again.
carried out, the printing machine can be The values last set are retained.
run up to the desired production speed.
3.6.3 Shuttung down for a longer period
3.6 Shutting down
If this unit is not to be used for a longer
period, it should be thoroughly cleaned.
3.6.1 Shutting down for a short period
Monitor 2 and controller 3 should be
switched off at the corresponding mains
During a short interruption of the
switch.
production process, no measures need to
be taken or adjustments made.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 7

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

3. Operation

3.7 Malfunctioning

See operating instruction "Video web


monitor system type EUROSCOP" of the
BST company.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 8

Base frame (overall length 390 mm)
EM 260/410/510 for video web monitoring

4. Care and maintenance

4.1 Qualification of staff When cleaning the additional equipment,


please follow the instructions of the
Cleaning and maintenance work may only manufacturer BST.
be performed by staff who are familiar
with the machine (see "General safety
instructions", item 1.1.5 "Responsibility of
staff" at the beginning of this manual).

4.2 Care

The base frame for video web monitor


system BG 55 should be thoroughly
cleaned after every job. Lubricants
removed during cleaning must be replaced.
Deflection rollers 6 should be cleaned only
with a soft cloth soaked in solvent

Caution :
Risk of damaging the deflection rollers.
Deflection rollers 6 must never be cleaned
with sharp or pointed objects.

arsoma
TN_ _0104/Operating instruction 09^ 55 S17-e/09^ 55 S18-e /19.04.01 Version:/ 9