DTZZIII-DK100 Series

Elevator Weight-Load Indicating Controller

1. Technical parameters and types

Type DK100 DK1 DK1 DK103


01 02
1.No 1.analog output is 0 1.analog output is -10 1. No
analog output ~ 10mA ~ 10V analog
Main 2.2.over load、full
2. over load 2. over output
feature
、 full load、full load、light load 2. over
load、light load load、light load load 、 full
load
Power AC220(-15~+10%)V
Source
Precision 1.0 class
Technology Sensitivity <0.1 %
parameter Control return difference <1 %
Working temperature -10 ~
60℃
Power consumption of instrument <10 W
Overload capacity of sensor 150 %
Output contactor capacity 0.3A/DC24V; 0.3A/AC220V
1. Product power source is AC220V;
Product 2. Product of the input signal connection mode are the same, as shown in the
common second; 3.The product output relays are move on and off;
4.Product installation are all the same, as shown in the three or four。

2.Control instrument appearance size and terminal functio

Control instrument appearance size


Picture

1
Terminal wiring diagram
Note:
1. The input signals can be contact can also be a level signal, connection mode as shown in the above.
Contact way connection, when the elevator upward, 1 close contact; When the elevator door, contact 2
closed; When the elevator flat layer 3 closed contact.
2. If the controller input signal need access to the double layer, while the flat direction on layer signal into the
original position, the flat layer signal access to the original position.
3. The installation size and control instrument

a、
Control cabinet install b 、Director install fittings
size Director install size picture
If the controller is installed directly in the elevator control cabinet, can use the M6 bolts, according to the
figure a direct control devices installed inside the control cabinet; If need to install in other places, you can
install the two attachments (figure b) fixed at the back of the chassis (figure a two M6 thread), then install the
control instrument accessories to a fixed location.
4. Sensor install picture

Sensor install picture


Note:
1. Additional rope head plate thickness of 20 ~ 25 mm, outside dimensions beyond hole outside around 30
mm.Sensors placed between two rope head plate, connected to the top and bottom line head plate
respectively, as shown above.
2. Sensors connected to the rope on the head plate bolt screw in sensor part cannot beyond sensor
junction surface under the surface.
3. Rope rod must avoid contact with the sensor head.
4. Rope head must be avoided by its rope head plate hole wall contact.

5、Initial review
Power on
Make the“set”switch on running,with power on, the controller will hear one long sound,three-digit display
888. Then the unit display 1,another two goes out. Open the door, three-digit will all display, and will increase
with the load of the elevator increasing.
reset
Make the“set”switch on running;
Power on and preheating for 10 minutes.
Let elevator empty and stay on the first floor, keep the door open. Press the reset button three times in three
seconds continuously, at the same time you will hear three short sounds, and then three long sounds,
three-digit display 000. Now the reset (get rid of the tare ) is finished.

6、Debugging (according to the site, choose any way is ok )

with duty load at site without duty load at


site

Input all the signal (up


direction, leveling, and door)
Keep it only can connect If the block is very high Keep it only can If the block is very high
the doorRapid
signal, or keep it or the height balance is connectofthe
Update load door signal,
capacity, or the height balance is
debugging, large or keep
can not connect any please refer itto method
can not 3 large
signal, and thenrefer
please keep the The full load debugging, connect any signal, and
to method
short wire connected1 then keep the short
please refer to method 2, this 1. Update of load capacity,
method wire connected
Input allis themost accurate
signal (up please refer to method 3
(recommendation)
direction, leveling, and 2.Empty load debugging,
door) please refer to method 4

Method 1 Rapid debugging


connect the door signal, and open the door.
after the initial test, keep the elevator empty and stay on the floor on which the dead weight of the car is most
light,then reset it.
After reset finished, keep the elevator stay on the floor on which the dead weight of car is most heaviest,
increase the load in the car to 100% of duty load, press the reset switch for more than 5 seconds, when hear a
long sound, release the switch, then the three-digit display 099-100;
Make the controller power off and then power on, the debugging is finishe d.

Method 2 full load debugging


After reset(get rid of the tare), keep the door open, make the load in the car to 100% of duty load, press the
reset switch for more than 5 seconds, when hear a long sound, release the switch, then the three-digit
display 099-100;
Press the set switch up to learning position, you will heard 3 long sounds and 1 short sound. Close the door,
make the elevator stay on every floor and open the door from the first floor to the top floor one by one.(stop on
every floor, the controller will learning and give a sound)
When reach the top floor, press the reset switch 5 times in 5 seconds continuously, at the same time you
will hear 5 gently sounds, and then 5 long sounds. Now make the elevator stay on every floor and open the
door from top floor to first floor one by one(stop on every floor, the controller will learning and give a sound).
After reach the first floor, keep the door open, press the set switch down to running position. The
instrument goes into normal operation, and the three-digit display 100.
ake the controller power off and then power on, the debugging is finished.
Method 3. update of load capacity
Make the elevator stay on the first floor and open the door, empty load and reset(ger rid of the tare).
Put the load in car to more than 20% of duty load, then record the actual value displayed on the nixie tube.
Make the controller power off and then power on again, press the set switch up to learning position, you will
hear 2 long sounds. Please press the reset switch immediately, at the same time there will be 1 gently sound,
now record the three-digit number which is the original default of duty load.
According to the actual value displayed、the value displayed in theory and the original default of duty load to
calculate the value of duty load in theory.
the value of duty load in theory=the actual value displayed×the original default of duty load÷the value
displayed in theory
Press the reset switch,adjust the original default of duty load to the value of duty load in theory. ( the value
between 020-255)
Return the switch to running position, make the controller power off and then power on again, now the
debugging is finished.
E.g: the duty load of elevator is 1000kg, when the load increase to 200kg, the value displayed in
theory should be 20% (increase load 200kg÷duty load 1000×100%), but the actual value displayed is 23%,
and the original default of duty load is 100, so the value of duty load in theory 23×100÷20=115, so adjust
the value of duty load in theory to 115 by hand will be ok.
Method 4. empty load debugging
1. First please reset (get rid of the tare ) the instrument.
2. Press the set switch up to learning position, you will heard 3 long sounds and 1 short sound.
Close the door, make the elevator stay on every floor and open the door from the first floor to the
top floor one by one.(stop on every floor, the controller will learning and give a sound)
3. When reach the top floor, press the reset switch 5 times in 5 seconds continuously, at the same
time you will hear 5 gently sounds, and then 5 long sounds. Now make the elevator stay on
every floor and open the door from top floor to first floor one by one(stop on every floor, the
controller
will learning and give a sound).
4. After reach the first floor, keep the door open, press the set switch down to running position. The
instrument goes into normal operation, and the three-digit display 000.Now the debugging is
finished.

7. set the light load point


When leaving factory, the default setting of light point is 10%. If you need reset the light point, please
operate as follow:
When the instrument work as normal operation (the elevator is empty), press the reset switch for 2
seconds, after hear a short sound, turn up the set switch, then after a long sound, you can debug it. Press the
reset switch to adjust the light load point. The value displayed between 002-050. When you adjust it ok, trun
down the set switch, and exit the debugging.

8.fault handling
In normal operation, if the instrument display 666, please check wether the sensor connect the controller
well.

Note: when the elevator opens the door, the instrument test the duty load, and output the contactor signal and
electricity signal. When close the door, the electricity signal will not change. If any question, or any faulty with
controller, please contact us in time.