Sie sind auf Seite 1von 18

Datasheet

ACUSON X700 Ultrasound System


Cardiovascular Applications
Release 2.0
ACUSON X700 Ultrasound System

Table of Contents
General System Information 
4 Freeze, Cine and Cine Post-Processing Functions 
9
System Architecture  4 Cine Review  9
User Interface  4 Post-Processing Features in Freeze Frame or Cine   9
Control Panel  5
System  5 Study Types 
9
Monitor  5
Exam-Specific Measurements and Reports 
10
Transducer Technology  5 Abdomen  10
Specialty Transducers  5 Cardiac  10
Intracardiac Echocardiography Transducers  5 Cerebrovascular  10
Transducer Ports   5 Peripheral Vascular  10
Transducer Storage   6 Venous  10
Hard Drive   6 TCD  10
Physiological Interface  6
Digital Patient Study Storage and Archiving 
10
Operating Modes 
6 Patient Study Management  10
2D  6
Advanced Technologies and Features 
11
Color Doppler  6
Dynamic TCE Technology  11
Spectral Doppler  6
Tissue Grayscale Optimization (TGO)   11
M-mode  6
SieClear Compounding   11
Display Modes  6 Advanced SieClear Spatial Compounding   11
2D-mode Image Processing  6 HD Zoom  11
MultiHertz Multiple Frequency Imaging  6 Spectral and Color Doppler Tissue Imaging (DTI)   11
Tissue Harmonic Imaging (THI)  7 DICOM 3.0 Connectivity  11
Focusing  7 DICOM Modality Worklist   12
2D Image Display  7 DICOM MPPS – Modality Performed Procedure Step   12
2D Calipers – Generic Measurements and Integrated Gel Warmer (Option)  12
Calculations  7 QuikStart (Option)  12
Color Doppler Velocity Imaging  7 Clarify Vascular Enhancement (VE) Technology   12
Power Doppler Imaging/Directional Power Doppler  7 SieScape Panoramic Imaging   12
Color and Power Doppler Display   8 Cardiovascular (Option)  12
Pulsed Wave Spectral Doppler  8 Physio Module (Option)  12
Steerable Continuous Wave (SCW) Doppler   8 CartoSound Communication (Option)  12
Continuous Wave Doppler  8 Stress Echo Imaging (Option)  12
Spectral Doppler Display  8 syngo fourSight TEE View (Option)  13
Spectral Doppler Calipers – Generic Measurements syngo Mitral Valve Assessment (MVA) (Option)  13
and Calculations  8 syngo Arterial Health Package (AHP)  13
M-mode  8 syngo Velocity Vector Imaging (VVI) Technology
M-mode Image Display  8 (Option)   13
M-mode Calipers – Generic Measurements and syngo Auto Left Heart (Auto LH) Technology
Calculations   9 (Option)  14
QuickSet User-Programmable System Parameters  9 Axius Edge Assisted Ejection Fraction   14

2
ACUSON X700 Ultrasound System

Intracardiac Echocardiography (ICE) Imaging


Options  14
Cadence Contrast Agent Imaging (Option)  15
Barcode Reader (Option)  15
DICOM Structured Reporting (Option)  15
Wireless Data Transfer (Option)  15
Ultrasound System Security – Virus Protection
(Option)  15

Documentation Devices 
15
Optional On-Board Video Devices  15

System Input/Output 
15
Video and Audio Input/Output (I/O)  15
System Interface Connections  15
Acoustic Output Management  16

System Dimensions 
16

Electrical/Environmental Specifications 
16

Integrating the Healthcare Enterprise (IHE) 


16

Standards Compliance 
16
Quality Standards  16
Design Standards  16
Acoustic Output Standards  16

CE Declaration 
16

EU Authorized Representative 
17

3
ACUSON X700 Ultrasound System

Sometimes, the most valuable ultrasound


feature is the one you can’t see. With the
ACUSON X700™ ultrasound system, we’ve
engineered a system that offers one of the
most critical innovations of all: confidence,
in both your diagnoses and your investment.
With the ACUSON X700 system, we had
the luxury of choosing features from some
of the most proven, sophisticated imaging
systems on the market, and packaging them
in a purpose-built platform. We’ve designed
the ACUSON X700 system with built-in
features that permit upgrades on your time-
table. This means you have the flexible
system you need today, and the freedom to
grow to meet the demands of tomorrow. • Enhance productivity through application-specific
imaging presets, TGO™ tissue grayscale optimization
technologies, enhanced measurement and report
functionality, knowledge-based workflow tools
including syngo® Mitral Valve Assessment (MVA),
General System Information syngo® Auto Left Heart (Auto LH), syngo® Velocity
Vector Imaging™ (VVI) technology, Axius™ edge
System Architecture assisted Ejection Fraction, QuikStart rapid boot and
All-digital signal processing and multi-beam formation standardized imaging protocols
technology provide best-in-class imaging in all modes and • Streamline connectivity with solutions such as DICOM
enable seamless integration of features and options to: Print/Store, DICOM Modality Worklist, DICOM MPPS
and DICOM structured reporting for Vascular and
• Allows for parallel Quad beam processing of the RF Cardiac exams
signal data in the time and amplitude domains new
• Increase functionality with integrated stress echo,
generation all-digital beamformer technology
syngo® fourSight™ TEE View, syngo® Arterial Health
–– System imaging frequency: 1.0 MHz to 17.0 MHz Package (AHP)*, ACUSON AcuNav™ ultrasound
–– 2D-mode line density: Up to 512 lines catheters and Cadence™ contrast agent imaging
–– Processing channels: Up to 344,064 channels technology**
–– Total system dynamic range: > 205 dB User Interface
• Native™ tissue harmonic imaging, DTO™ Dynamic • On-screen text, control panel overlay and operating
Tissue Optimization technology, Dynamic TCE™ instructions are available in the following languages:
tissue contrast enhancement technology, SieScape™
–– Chinese
panoramic imaging, Advanced SieClear™ spatial
compounding, SieClear™ compounding and Clarify™ –– English
vascular enhancement (VE) technology are built into –– French
the ACUSON X700 system to provide excellent image –– Italian
quality –– German
–– Spanish
• Russian keyboard and operating instructions supported
• Operating instructions are available in 17 additional
languages

** T his feature should be utilized according to the ASE Consensus Statement “Use of Carotid Ultrasound to identify Subclinical Vascular
Disease and Evaluate Cardiovascular Disease Risk: A Consensus Statement from the American Society of Echocardiography Carotid Intima-
Media Thickness Task Force, Endorsed by the Society for Vascular Medicine.“
** At the time of publication, the U.S Food and Drug Administration has cleared ultrasound contrast agents only for use in LVO. Check current
regulations for the country in which you are using this system for contrast agent clearance.

4
ACUSON X700 Ultrasound System

• Thumbnail menu provides on-screen thumbnail • (4) Illumination controls including menu, increase,
images and dynamic clips during exams decrease and light
• On-screen acoustic power indicator (AIUM/NEMA • Angle of view: 178°
output display standard)

Control Panel Transducer Technology


• Simple, intuitive user interface with Home Base
design minimizes repetitive hand motions and enables Ultra-sensitive wideband transducers, matched with
motor-memory learning user-selectable MultiHertz™ multiple frequency imaging,
improve resolution and penetration. Up to seven 2D and
• A floating control panel allows for a wide range of
THI frequencies and up to two color Doppler and spectral
adjustments for operator comfort in standing and
Doppler frequencies expand the clinical versatility of
sitting positions
a single transducer, thereby maximizing transducer
• Left/Right swivel articulation ± 90° investment.
• Vertical adjustment: 10 cm
• Backlit key illumination • Innovative ultra low-loss lens materials and micro­
electronic technologies for efficient performance and
• Variable key brightness indicates active functions
increased signal bandwidth
• Multi-level task light: ON, 1, 2, 3, OFF
• microCase™ transducer miniaturization technology
• Customizable soft keys for easy and immediate and SuppleFlex™ transducer cables
viewing of on-screen menus
• SuppleFlex cables and integrated cable management
• Full-size QWERTY keyboard supports text entry, provide protection during exams and transport
function keys and system programming
• Independent 2D and color frequencies for optimal
• Wrist support to help reduce operator fatigue resolution and penetration
System • Frequency range: 1.3 – 16.0 MHz
• Height-adjustable and swivel control panel • Hanafy lens acoustic technology
• Control panel with lock lever • Universal, stainless steel and disposable biopsy
• Multi-directional articulating monitor arm to help guides for specified linear and curved array
improve ergonomics transducers

–– Arm rotation: - 90° to + 90° Specialty Transducers


–– FPD rotation: - 80° to + 80° The ACUSON X700 system supports a range of trans­
–– Tilt: 15° to 90° ducers and capabilities, including TEE and Intracardiac
–– Up: 125 mm Echocardiography transducers. For more detailed trans­
ducer information, please consult the Transducer Flyer.
–– Pull: 250 mm
• Integrated high performance audio speakers Intracardiac Echocardiography Transducers
• Wheels • ACUSON AcuNav™ 10F ultrasound catheter –
–– Castor size: 125 mm Adult intracardiac echocardiography

–– Front castor (2 ea): Bi-brake system (direction lock • ACUSON AcuNav™ 8F ultrasound catheter –
and total lock) Adult intracardiac echocardiography

–– Rear castor (2 ea): Total lock • CartoSound™ Communication – Adult intracardiac


echocardiography with SoundStar™ 3D catheter*
Monitor
Note: See dedicated transducer flyer for more
• Flat Panel Display (LED/LCD), 20-inch widescreen,
information.
color, high resolution, and progressive scan (non-
interlaced) with In Plane Switching (IPS) technology Transducer Ports
• Resolution: 1600 x 900 pixels • (3) Active transducer ports that support high
• Total screen area: 1600 x 900 pixels density phased array, curved array and linear array
transducers
• Recordable image area clips: 1024 x 768 pixels
• Electronic transducer selection (instantaneous
• Total screen capture: 1600 x 900 pixels
switching between transducers)
• Monitor tilt: 15° up, 90° down and swivel of ± 80°
• Digital on-screen display of brightness control
* F or purchase or inquires, contact Biosense Webster: USA
• Energy saving display power management (1-909-839-8500 and 1-800-729-9010), Belgium (+32-2-352-1411)

5
ACUSON X700 Ultrasound System

• Supports 512 micro-pinless (MP) and DL (260) type • Continuous wave – pencil probe
connectors
• Spectral Doppler tissue imaging
• Industrial design provides easy access to the
• Duplex and Triplex modes
transducer ports
M-mode
Transducer Storage
• Color M-mode
• (6) Configurable transducer holders support all
transducer designs and provide gel bottle storage • Anatomical M-mode
• Special transducer holder provides secure storage • ECG trace in all modes
and easy access to endocavity transducer
• Transducer holders can be removed for cleaning Display Modes
Hard Drive • Selectable split screen display formats in 2D or
• Internal 500 GB hard drive 2D/color with M-mode and/or spectral Doppler mode:
• Allows storage of patient studies that include images, top-bottom or side-by-side in real-time and digital
clips, reports and measurements cine replay
• Image storage capacity up to 300,000 images with • 4B-mode allowing simultaneous display of 4 static
compression B-mode images
• For more detailed information, please consult the • Virtual Format
Digital Patient Study Storage and Archiving section • Dual from freeze
on page 10 • Split/Zoom
Physiological Interface
Flexible combination of imaging modes in side-by-side
• Standard 3-lead ECG interface
Dual and Dual Select in real-time, and digital cine replay.
• Auxillary Input for ECG and other physiology signals
from third party devices 2D-mode Image Processing
• Continuous display in all real-time modes • All-digital parallel signal processing with frame rate
• R-Wave single and dual trigger function up to 498 fps (transducer dependent)
• Respiratory trace • MultiHertz imaging: Up to 7 user-selectable transmit
frequencies
• Heart rate display
• Res/Speed selection: 6 levels
• Adjustable gain and trace position on-screen
• Persistence: 5 levels
• Recovery time: Less than 2 seconds
• Edge enhancement: 4 levels
• Dynamic range selection: 30 – 90 dB in 3 or 5 dB
Operating Modes increments, application dependent
• Gain: - 30 to + 30 dB in 1 dB increments
2D
• DTO technology: 3 levels
• Fundamental 2D
• Dynamic TCE technology: 3 levels
• Phased THI
• Depth/Gain compensation: 8 controls
• Filtered THI
• User-selectable gain balance: 9 maps
• Alternating THI
• User-selectable 2D colorization: 16 maps
Color Doppler • Maximum display depth: 30 cm
• Velocity-based color Doppler • Minimum display depth: 1 cm
• Power Doppler
MultiHertz Multiple Frequency Imaging
• Directional power Doppler
Siemens’ unique MultiHertz multiple frequency imaging
• Color M-mode is designed to combine the resolution and penetration
• Color Doppler tissue imaging of several transducers into one. At the push of a button,
the user can independently change frequencies for 2D,
Spectral Doppler
THI, color and spectral Doppler to select the optimal com­
• Pulsed wave bination for image resolution, penetration and sensitivity.
• Steerable continous wave (SCW)

6
ACUSON X700 Ultrasound System

• Transmit frequencies: Up to 7 user-selectable –– Distance measurement


frequencies –– Depth measurement from skin line
–– 2D and M-mode: Up to 3 fundamental frequencies –– Angle measurement
–– THI: Up to 5 frequencies –– Area and circumference: ellipse, trace
–– Color, power, or pulsed wave Doppler modes: • Compound Measurements
Up to 2 frequencies –– Volume: user-selectable preset by 1 distance,
–– SCW Doppler mode: 1 frequency 2 distance, 3 distance, or 1 ellipse and 1 distance
Tissue Harmonic Imaging (THI) –– Flow volume: 1 velocity and 1 distance, or
1 velocity and 1 ellipse
Selectable harmonic frequencies increase success with
difficult-to-image patients, improving diagnostic con­ –– Stenosis: user-selectable preset calculated by
fidence, and dramatically improving contrast and spatial 2 ellipse or 2 distance measurements
resolution by reducing noise and clutter in the image. Color Doppler Velocity Imaging
• MultiHertz imaging capability in THI • Available on all imaging array transducers
• Available on the 4C1, 4V1c, C8-5, P8-4, VF10-5, • Multi-beam formation technology provides quad
VF12-4, VF16-5 and V5M transducers signal processing for color Doppler frame rates up to
177 fps (transducer dependent)
Focusing
• Transmit frequencies: Up to 2 user-selectable
• Transmit focal zones: Up to 4 zones frequencies per transducer
• Digital dynamic receive focusing with dynamic • Left/right steer on all linear transducers
apodization
• Color Doppler invert
• Multi-position, user-selectable position
• Advanced processing in color Doppler mode
• Can use multiple focal zones simultaneously resulting in excellent spatial resolution and superior
Flash suppression
2D Image Display
• AutoColor flow state optimization with high, medium
• Full screen, Split, Quad and Dual Select screen
and low flow settings
formats as well as Dual, Dual seamless, Dual select
and Dual from Freeze • Color Doppler velocity maps: Up to 9 user-selectable
maps (7 velocity and 2 velocity/variance)
• Curved Vector format
• Velocity scale range: ± 0.6 – ± 244.4 cm/sec
• L/R flip and U/D flip for all formats in real-time and
digital cine replay • PRF scale range: 100 – 19,500 Hz (transducer
dependent)
• Split/Zoom
• Gain: -20 – 20 dB in 1 dB increments
• Image depth: 1 – 30 cm in 1.0 cm increments
(transducer dependent) • Color Doppler line density: 6 selections
• Virtual Format Imaging (transducer dependent) • Wall filter: 4 selections
–– Left/right steer • Color smoothing: 4 levels
–– Trapezoid Imaging • Tissue/color priority: 5 selections
• Digital read/write Zoom with image pan • Color Doppler persistence: 5 levels
–– Available on live and cine replay images • Velocity tag
–– At least 2.5x and up to 10x zoom (transducer • Peak hold: Off, 1 sec, 2 sec and 3 sec
dependent) • DTI™ Doppler tissue imaging capability available on
• 4B-mode select transducers
• 90° image rotation (all linear transducers) Power Doppler Imaging/Directional Power Doppler
2D Calipers – Generic Measurements and Calculations • Available on all imaging array transducers
• Multiple cursor sets on frozen, live, dual screen and • Multi-beam formation technology provides quad
cine playback images signal processing for power Doppler frame rates up
to 195 fps (transducer dependent)
• Distance measurements: Up to 8 measurements per
screen • Left/right steer on all linear array transducers
• Transmit frequencies: Up to 2 user-selectable
frequencies per transducer

7
ACUSON X700 Ultrasound System

• Power Doppler maps: Up to 16 maps • Baseline shift: 17 levels


(8 directional and 8 non-directional) • Spectral invert
• PRF scale range: 100 – 19,500 Hz (transducer • Autotrace function is not supported in SCW mode
dependent)
Continuous Wave Doppler
• Gain: -20 – 20 dB in 1 dB increments
• Supported on the CW2 and CW5 transducers
• Power Doppler line density: 6 selections
• Wall filter: 4 selections Spectral Doppler Display
• Power Doppler smoothing: 4 levels • Full screen Doppler trace, 2D/Doppler mode, triplex
• Tissue/power Doppler priority: 5 selections or update 2D/C/Doppler
• Color persistence: 5 levels • Imaging display: 4 formats
–– Top-bottom: 1/3-2/3, 1/2-1/2, 2/3-1/3
Color and Power Doppler Display
–– Side-by-side: 40-60
• 2D/C mode, Split 2D-2D/C mode
• Dual real-time 2D/C mode Spectral Doppler Calipers – Generic Measurements and
Calculations
• 2D/C/D mode (simultaneous triplex), 2D/C/D mode
(update) • Multiple cursor sets on frozen and cine playback
images
Pulsed Wave Spectral Doppler • Velocity/Frequency/Pressure Gradient
• Available on all imaging array transducers • Heart rate/Heart cycle/Time
• Transmit frequencies: Up to 2 user-selectable • Autotrace measurements in real time and freeze
frequencies per transducer including calculations for PS, ED, TAMx, TAMn, PI, RI
• DTI capability available on select transducers and S/D
• Sweep speed: 8 selections • Resistive Index (RI)
• Post-processing gray maps: 8 maps • Pulsatility Index (PI), including Peak-to-Peak method
• Doppler colorization maps: 12 user-selectable maps • Time Average Velocity max (TAV)
• Gain: 0 – 90 dB in 1 dB increments • Systolic/diastolic ratio (S/D)
• PRF range: 100 – 19,500 Hz • Velocity Time Integral (VTI)
• Velocity scale range: ± 1.5 – ± 350 cm/sec with • Acceleration/Deceleration
0° angle correction • Flow volume using combined velocity and distance,
• Angle correction: 0 – 89° in 1° increments or velocity and ellipse measurements
• Gate size: 0.2 – 20 mm • Doppler angle correction after measurement
• Wall filter: 25 – 3906 Hz, 8 steps
M-mode
(transducer dependent)
• Available on all imaging array transducers
• Baseline shift: 17 levels
• Anatomical M-mode – live, cineloop and DIMAQ
• Spectral invert
image review
• Autotrace function
• Frequencies: Up to 5 user-selectable frequencies,
Steerable Continuous Wave (SCW) Doppler including fundamental and harmonics
• Available on all phased array transducers when • Edge enhancement: 4 selections
Advanced Cardiovascular option is purchased • Display dynamic range: 30 – 70 dB in 5 dB increments
• Transmit frequency: 1 frequency • Gain: -30 – 30 dB in 1 dB increments
• Sweep speed: 8 selections • Gray maps: 9 maps
• Post-processing gray maps: 8 maps • M-mode colorization maps: 16 maps
• Doppler colorization: 12 maps • Sweep speed: 8 selections
• Gain: 0 – 90 dB in 1 dB increments
M-mode Image Display
• PRF range: 1.56 – 34.7 kHz sample rate
• Full screen M-mode, 2D/M-mode
• Velocity scale range: ± 30 – ± 650 cm/sec with
• Imaging display: 4 formats
0° angle correction
–– Top-bottom: 1/3-2/3, 1/2-1/2, 2/3-1/3
• Wall filter: 25 - 6944 Hz. 8 steps (transducer
dependent) –– Side-by-side: 40-60

8
ACUSON X700 Ultrasound System

• Acoustic clip capture from cine review


• Anatomical M-mode available

Post-Processing Features in Freeze Frame or Cine


• 2D-mode
–– Zoom/pan
–– Gray map
–– Colorization map
–– Measurements/reports/annotations/pictograms
• Color Doppler
–– Zoom/pan
–– Color map
–– Color invert
–– Measurements/reports/annotations/pictograms
• Spectral Doppler
–– Gray map
–– Doppler colorization map
M-mode Calipers – Generic Measurements and –– Angle correct
Calculations –– Measurements/reports/annotations/pictograms
• Multiple cursor sets on frozen and cine playback • M-mode
images
–– Gray map
–– Distance
–– M-mode colorization map
–– Time
–– Measurements/reports/annotations/pictograms
–– Slope
–– Heart rate
Study Types
QuickSet User-Programmable System Parameters
All imaging modes and parameters are customizable and The ACUSON X700 system is designed to support many
programmable using QuickSet user-programmable system cardiac and vascular imaging applications. Factory-supplied
parameters. exam and transducer dependent imaging presets have
been carefully optimized for each application to provide
• Up to 32 QuickSet parameters supported consistency, reliability and increased productivity. All
• QuickSet parameters combine all preferred applications include body markers, text and annotation
imaging mode parameters, annotation, text and labels. Selected applications support customized work­
measurements into a single user preset sheets and reports. The following study types are supported:

• Abdominal
Freeze, Cine and Cine  • Renal
Post-Processing Functions • Adult Cardiac (Transthoracic)
• TEE Adult
Cine Review • Intracardiac Echo (ICE)
The cine feature is standard and offers the ability to • Vascular (C-Vas, P-Vas, Venous)
review real-time acquired data. All real-time, post-acqui­ • Cranial (TCI & TCD)
sition optimization functions are available in cine review.

• Frame-by-frame cineloop review and continuous cine


motion review, including control of playback rate
• Independent cine review in mixed modes (2D/M,
2D/Doppler, 2D/C/Doppler)
• Independent cine review in 2D Dual Select mode with
image align playback feature
• Standard cine memory: Up to 2729 frames

9
ACUSON X700 Ultrasound System

The ACUSON X700 system supports customizable labeled


Exam-Specific Measurements measurements (20 B-mode, 5 Doppler and 5 M-mode) for
and Reports the following exam types: Abdomen, Venous and Renal.
Additionally, all reporting packages support user-defined
All measurement and report packages are available for descriptors (up to 39).
use with all exam types.
All exam specific measurement and reports support:
• All general measurements and calculations Digital Patient Study Storage and 
• Comprehensive, customizable, patient reports and Archiving
worksheets
The DIMAQ-IP integrated workstation allows for digital
• Customizable anatomy descriptions acquisition, storage and review of complete ultrasound
• Physician summary utility – supports on-system studies, including static images, dynamic clips, measure­
report generation including customizable letterhead, ments, calculations and reports.
patient data, results, graphs, images, comments,
recommendations and a customizable signature line Studies can be reviewed and quantified on-board, stored
on the system hard drive and transferred to the built-in
The following Measurements and Reports packages are DVD multi-drive (DVD-R/RW & CD-R/RW) or USB Flash drive
available on the ACUSON X700 system: for cost-effective archival.
Abdomen Patient Study Management
Cardiac Playback of digitally stored images in a selectable 1-up,
• Adult standard measurements 4-up, 9-up, 16-up or 25-up screen format. The patient
study screen allows search, selection and deleting of studies
• Volume formulas for Left Ventricular function assess­
or export to DVD multi-drive (DVD-R/RW and CD-R/RW).
ment in 2D-mode and M-mode
• 2D-mode, M-mode and Doppler calculations • 300 GB (of the 500 GB internal hard drive) internal
• M-mode Slope, Heart Rate, Time and Distance hard drive reserved for patient data management
measurements –– Patient database sorting by Name, ID and Study Date
• Spectral Doppler Acceleration, Trace, Heart Rate, • Hard drive capacity:
Time and Velocity measurements –– Approximately 300,000 B/W and color images
• Cardiac patient report and worksheet for 2D-mode, • Storage and retrieval of static images
M-mode and spectral Doppler
• Storage and retrieval of cine clips
Cerebrovascular –– Retrospective clip capture during real-time imaging
• CCA prox, CCA mid, CCA dist, ICA prox, ICA mid, with a selectable duration of 1, 2, or 4 seconds or
ICA dist, ECA and VA measurements a selectable duration of 1, 2, 3 or 4 beat capture;
• Area Percent Stenosis and Diameter Percent Stenosis ECG triggerable
measurements –– Prospective clip capture during real-time imaging
with a selectable duration of 1 to 120 seconds or
Peripheral Vascular a selectable duration of 1 to 120 beat capture;
• CIA, EIA, CFA, PFA, SFA prox, SFA mid, SFA dist, ECG-triggerable
POP A, TRUNK ATA, PTA, PER A and DPA measurements • Export of patient studies from hard drive
• Right and left extremity measurements • Storage and retrieval of reports
Venous • Supports measurements and calculations on archived
• Right and left extremity measurements study and on saved and retrieved images
• Acoustic clip capture from cine review
TCD
• M-mode still frame scroll and store
• MCA, ICA-Siphon, ACA-A1, ACA-A2, ACoA, PCA-P1,
• PW spectral Doppler still frame scroll and store
PCA-P2, PCoA, PCA, Basilar A and Vert A measurement
• Export of patient studies from hard drive to DVD-R/
RW and CD-R/RW drive. Studies can be individually
selected or batched copied

10
ACUSON X700 Ultrasound System

• The system supports the following data export SieClear Compounding


file formats: RTF, PDF, TIFF, AVI, JPG and DICOM. The SieClear compounding option uses multiple lines of
Connectivity to PACS, other off-line storage (such as sight to increase contrast resolution and improve tissue
USB flash drive) or EMR device is achieved via LAN differentiation of low contrast lesions by reducing image
or WLAN connection. speckle. Tissue boundaries and interfaces appear sharper
• Compatible with removable 650 MB, 700 MB and and more continuous. SieClear compounding is accessible
790 MB CD-R and 650 MB or 700 MB CD-RW in THI and is compatible with other advanced imaging
• Removable 4.7 GB single layer DVD and 8.5 GB single options including SieScape imaging, TGO technology and
side double layer DVD Clarify vascular enhancement technology.
• Supports export to USB Flash Drive
Advanced SieClear Spatial Compounding
This feature combines two distinct technologies to
Advanced Technologies and  create exceptional image quality: Advanced SieClear
Features spatial compounding and SieClear compounding. This
combination of technologies provides exceptional
Dynamic TCE Technology improvements in border definition.
• Dynamic TCE technology is a proprietary, advanced • Up to 7 steering angles available on linear
post-processing method for speckle reduction transducer, 5 available on curved array transducers
• Compatible with other advanced imaging modes • Supports all primary and secondary exam types
including Advanced SieClear compounding, THI and
TGO technology HD Zoom
• Supports all primary and secondary exam types High density zoom function to obtain a region of interest
• Three levels available: Low, Medium and High with increased detail resolution.

Tissue Grayscale Optimization (TGO) • Ability to enlarge areas of interest with no loss of detail
TGO tissue grayscale optimization technology provides • Increased boundary resolution of cystic regions, vessels
one-button image optimization. It automatically adjusts and hypoechoic regions
image brightness to the tissue type being imaged and
Spectral and Color Doppler Tissue Imaging (DTI)
equalizes the overall image gain. The user-definable
threshold accommodates different user preferences for • Supports both color DTI and spectral DTI functionality
gain settings and various room lighting conditions. TGO and includes a quantification package
technology improves the consistency and quality of the • Enables assessment of LV diastolic function on the
ultrasound images to enhance productivity by removing ACUSON X700 system
time-consuming and operator-dependent manual –– Spectral Doppler DTI capability utilizes real-time
adjustments. TGO technology can be used with every Doppler shift information from moving tissue to
transducer, for every exam type and at every imaging better visualize and quantify myocardial diastolic
frequency, including THI. function
–– The spectral Doppler DTI calculation package pro-
vides guided velocity and acceleration measure­
ments and includes a measurement report package
–– Color DTI capability can be used for qualitative
evaluation of wall motion and displays the relative
change of velocities
–– Color DTI M-mode
–– DTE (Doppler Tissue Energy)

DICOM 3.0 Connectivity


Enables digital data transfer via a DICOM network for
both printing and storage. The ACUSON X700 system acts
as a DICOM Storage Class User and DICOM Print Class User.

11
ACUSON X700 Ultrasound System

Functionality supported: Clarify Vascular Enhancement (VE) Technology


• Connectivity to PACS system for storage of all digital Clarify VE technology is a real-time, adaptive, pixel-by-
images and dynamic clips with patient demographic pixel analysis implemented through a simple, time-saving
data user interface that provides multiple levels of clarification
• In-progress store during the exam to optimize tissue contrast resolution and definition of
both tissue and vessel walls according to user preference.
• Image printing to DICOM color and grayscale printers
Clarify VE technology is available on all curved and linear
• DICOM storage commitment transducers.
• DICOM exchange media export to DVD-R/RW and
CD-R/RW SieScape Panoramic Imaging
• DICOM region calibration Grayscale panoramic imaging allows acquisition and
display of images up to 60 cm in length to a maximum
• DICOM interchange media viewer software
curvature of 360°.
SHOWCASE®
• Interchange media database that identifies the CD • Available on all curved and linear transducers
to which the patient study has been burned • Can be displayed in full field acquisition or zoomed
DICOM Modality Worklist for detail viewing
Enables query and direct download of the patient worklist • Measurements available
schedule from the Hospital/Radiology Information System Cardiovascular (Option)
(HIS/RIS) to the ACUSON X700 system, automatically
Contains the prerequisites to perform cardiac and certain
populating the “New Patient” screen with patient demo­
vascular exams:
graphic information.

DICOM MPPS – Modality Performed Procedure Step • Physiological interface


Enables automatic exchange of Modality Performed –– Standard 3-lead ECG interface
Procedure Step information with the Hospital/Radiology –– Aux ECG interface
Information System (HIS/RIS). –– R-Wave single and dual trigger function
Integrated Gel Warmer (Option) –– Heart rate display
• Temperature control precision: ± 1° –– Adjustable gain and trace position on screen
–– Low: 31° C –– Selection for external ECG input
–– Medium: 34° C –– Respiratory function
–– High: 37° C • Steerable Continuous Wave Doppler module
• Easy-to-use power on/off control switch • Auxiliary Continuous Wave Doppler module
• LED color for status indicator Physio Module (Option)
–– Standby mode: Off • Provides the ability to configure ECG capabilities for
–– Operating mode: Orange specialty applications that do not require Continuous
• Safety protection for electrical overload Wave Doppler capabilities
• Weight: ~ 480 g • AUX ECG and Respiratory functions are supported in
addition to conventional Physio Module
• Size: 83 mm x 123 mm x 103 mm
CartoSound Communication (Option)
QuikStart (Option)
This license enables Ethernet communication between
QuikStart reduces time required for power-up and
the ACUSON X700 system and the Biosense Webster
power-down events by allowing the system to enter a
CartoSound™ system.
specialized mode.
Stress Echo Imaging (Option)
• Standby mode power-down in 3 sec; complete
The stress echo package provides tools for ECG-triggered
boot-up in less than 12 sec
acquisition, display, selection comparison, evaluation and
• Standby time: > 40 min archiving of multiple cardiac loops during various stages
• Full recharge: < 180 min of a stress echo examination.

• Standard acquisition protocols for treadmill, ergo­


metric and pharmacological stress including:

12
ACUSON X700 Ultrasound System

–– Multiple factory default stress echo protocols syngo Arterial Health Package (AHP)
–– Customizable stress echo protocols syngo Arterial Health Package provides the clinician with
–– Flexible combination of imaging modes while in the capability to measure Carotid Intima-Media Thickness
stress echo package (CIMT) and the option to reference normative tables that
–– Ability for customized studies through Protocol have been validated and published in peer-reviewed
Editor, with up to 12 stages, 6 views per stage, studies.1 The information is intended to provide a straight-
forward tool for communicating with patients the relative
20 loops per view or 120 sec prospective clip
state of their cardiovascular system.
capture
–– Full screen or ROI (region of interest) acquisition This feature should be utilized according to the ASE Con­
• Complete R-R capture with clip editing sensus Statement, “Use of Carotid Ultrasound to Identify
• Easy workflow throughout the exam protocol Subclinical Vascular Disease and Evaluate Cardiovascular
Disease Risk: A Consensus Statement from the American
• Stage Timer
Association of Echocardiography; Carotid Intima-Media
• Prospective continuous capture (up to 120 seconds) Thickness Task Force, Endorsed by the Society for Vascular
or Retrospective labeled capture Medicine.”
• Reference image display during acquisition
syngo Velocity Vector Imaging (VVI) Technology
• Immediate review of acquired loops
(Option)
• Flexibility to skip views or stages
syngo VVI technology visualizes, measures and displays
• Flexibility to re-acquire and overwrite already global and regional myocardial motion and mechanics
acquired images from a 2D image and sophisticated tracking algorithm.
• Indication of current view, acquired views and Using individual vectors to display direction and relative
skipped views in the workflow diagram velocity (based on length of the vectors) of frame-to-
• Wall Motion Scoring, 16/17 segment model with frame tissue movement, syngo VVI technology delivers
graphical display and report printing motion measurement at any point in the cardiac cycle.
• LV Volume Measurements with report printing syngo VVI technology provides a unique graphical presen­
tation of the mechanics of myocardial function.
syngo fourSight TEE View (Option)
An integrated method which provides acquisition, review, • Algorithm processes ultrasound clips obtained in
manipulation and dynamic display capabilities of gated all views of the heart, as well as generic moving
3D datasets using the V5M transesophageal transducer. tissue (e.g. vessel wall) not limited by Doppler angle
dependencies, frame rate or mean velocities
• 3D surface (volume) rendering for detailed • ECG signal is not required, allowing use with fetal
anatomical display echo
• D’Art is an intuitive navigation tool with adjustable • Tracking algorithm incorporates multiple sources of
indicator for line of sight direction information, including speckle tracking
• Utilizes two cut planes positioned perpendicular to • Displays include:
the selected line of sight –– Visual assessment of wall motion and vector
• Dynamic MultiPlanar reconstruction dynamics
• Viewing presentation enhanced by zoom, pan and –– Time curves of the selected velocity vector
rotate functions components
• Easy to use, rapid acquisition, enhanced workflow –– 3D representations of parametric color M-mode
syngo Mitral Valve Assessment (MVA) (Option) –– Selected components of tissue velocity (tissue
strain and tissue strain rate)
An integrated method which, in conjunction with
syngo fourSight TEE view, enables a detailed assessment –– Time curves of global and segmental LV volumes
of mitral valve morphology from 3D images for a more and Ejection Fraction
accurate and complete diagnosis of pathology location –– Synchrony analysis including time-to-peak
and size. Performs measurements for: • Compatible with standard acquisition frame rate
clips and acoustic clip capture (e.g. isovolumetric
• Angle
contraction and relaxation events)
• Size
• Distance 1  RIC- G Howard, et al: “Carotid artery intimal-media thickness
A
• Area distribution in general populations as evaluated by B-mode
ultrasound, ARIC Investigation”: Stroke 1993;24;1297-1304.

13
ACUSON X700 Ultrasound System

syngo Auto Left Heart (Auto LH) Technology (Option) • Reusable SwiftLink catheter connector (MP type)
• Calculated confidence (additional SwiftLink connectors are optional)
–– Uses pattern recognition technology based on a • 10 sterile covers
comprehensive database representing typical adult • Complete echocardiography exam capabilities during
transthoracic exams intracardiac minimally invasive procedures, such as
–– Provides robust performance and expert-like atrial fibrillation ablation, transcatheter septal closure
consistency in every exam device placement, pacemaker lead placement, trans­
–– Excels in technically difficult studies as learning is septal catheterization and balloon valvuloplasty or
largely independent of image quality septostomy

• Automated workflow • Visualization of cardiac anatomy and regional


myocardial tissue motion, great vessels and vascular
–– Bypasses the cumbersome “mark-and-trace”
anatomy, blood flow direction, blood flow velocity
method to calculate EF, end diastole volume and
and other devices located within the heart
end systole volume
• Sterile, steerable, single-use catheter
–– Automatically identifies ED and ES frames and
tracks endocardial borders frame to frame • High resolution, high frame rate imaging in multiple
modes, including: 2D, M-mode, PW spectral Doppler,
–– Promotes smooth, efficient workflow with manual
CW spectral Doppler, color Doppler velocity and Doppler
edit options
tissue imaging (optional)
–– Reduces observer variability to yield more consistent,
• Digital phased array technology
standardized measurements
• Imaging penetration up to 14 cm allows for visuali­
• Consistent, reliable and convenient
zation of left-sided cardiac anatomy from within the
–– Extends calculation accuracy to broaden clinical right atrium or right ventricle
confidence
• Two planes of bi-directional steering of the catheter
–– Presents EF measurement in complete perspective tip (160° in each direction: anterior-posterior/left
– with image frames for ED and ES with numerical right) for maneuverability, rapid anatomic orientation
and graphical data and micro-positioning
–– Available off the system with syngo® US Workplace • Longitudinal side-fire imaging provides standard
–– Operates on DICOM clips from select Siemens and echocardiographic views, similar to TEE, for easier
non-Siemens ultrasound systems orientation

Axius Edge Assisted Ejection Fraction • QuikSet user-programmable system parameters


provide instant image optimization
Axius ejection fraction calculates left ventricle volumes
and ejection fractions quickly and reliably. • Tension control knob for holding the desired catheter
curvature
• Enhances workflow by allowing the user to indicate • 64-element digital phased array with simultaneous
three boundary points for measurement instead of a processing for the highest imaging resolution in all
manual trace of the ventricle modes
• Utilizes the Simpson method for LV volume • Access to advanced imaging modes provides full
calculations based on LV endocardial border trace echocardiography capabilities, including:

Intracardiac Echocardiography (ICE) Imaging Options –– 2D imaging

Adult and pediatric intracardiac echocardiography (ICE) –– M-mode


using the ACUSON AcuNav ultrasound catheter family. –– Pulsed Wave (PW) spectral Doppler
–– Continuous Wave (CW) spectral Doppler
• Disposable ACUSON AcuNav 8F ultrasound catheter
–– Color Doppler velocity capability
–– 8 French catheter (cross-sectional diameter 3.3 mm),
–– DTI Doppler Tissue Imaging capability
90 cm insertable length
–– Comprehensive measurements and calculation,
• Disposable ACUSON AcuNav 10F ultrasound catheter
including volume, function and hemodynamics
–– 10 French catheter (cross-sectional diameter
• MultiHertz imaging
2.7 mm), 90 cm insertable length
• Zoom capabilities
• Ultrasound catheters must be purchased separately

14
ACUSON X700 Ultrasound System

Cadence Contrast Agent Imaging* (Option) The Wireless Option supports connectivity with:
Provides excellent detection of the responses from con­ • DICOM services – Modality worklist, print, storage
trast agent microbubbles, coupled with a high resolution commitment and store
display. The ability to simultaneously detect both the • Siemens Remote Service – Remote update handling
signals returning from the contrast agent and the signals for storage distribution and NetViewer for remote
arising from tissue allows the user to switch between application support and remote troubleshooting
a contrast-only display and a tissue-only display for
instantaneous confirmation of contrast presence and Technical Specification
position, providing real-time flexibility and enhanced • Standards: IEEE 802.11n, 802.11g, 802.11b, 802.11a
diagnostic confidence. • Security features: WEP, WPA, WPA2 personal, WPA
and WPA2 Enterprise
• Optimized for 4C1 transducer for abdominal
applications ASUS – Supported in all countries

• MultiHertz imaging provides improved fine-tuning for Ultrasound System Security – Virus Protection (Option)
low-MI contrast investigations Embedded virus protection solution that protects the
• Integrated burst/reflow control for destruction, system against advanced persistent threats, viruses,
reperfusion investigations malware and other executing software by detecting
• On-screen stopwatch feature and preventing any unwanted change to improve IT
• Frame rate triggering with extended clip capture compliance and security.
times of up to 20 minutes
• Burst (bubble destruction) mode Documentation Devices
Barcode Reader (Option)
Optional On-Board Video Devices
• Allows fast and accurate patient information data
• Up to 2 documentation devices (B/W printer and
input
color printer/DVR recorder) can be integrated into the
• Easy attachment to USB port system cart and controlled from the system control
• Supports 2D and 1D patient barcode panel
• Can scan up to 3 individual barcodes: patient, • Supported devices:
physician and sonographer –– Mitsubishi USB P95DW B/W Printer
• Inputs the following patient identifying data: –– Sony UP-D897 B/W Printer
–– Patient Name (First and Last) –– Mitsubishi USB CP30DW Color Printer
–– Patient ID –– Sony UP-D25MD Color Printer
–– Physician ID –– TEAC DVR UR-50BDS
–– Sonographer

DICOM Structured Reporting (Option) System Input/Output


DICOM Structured Reporting (SR) provides a standardized
report architecture to allow for easy transfer of measure­ Video and Audio Input/Output (I/O)
ments to offline PCs, workstations and archiving systems. • VGA out and DVI out
DICOM Structured Reporting will automatically populate
• DVI in/out
measurements to their respective fields in an external
software package. This option is available for the follow­ • External audio out
ing applications: System Interface Connections
• Vascular • Network
• Cardiac –– (1) Ethernet connector, type RJ45 (10/100 BaseT)
Wireless Data Transfer (Option) • Peripherals
Utilizes USB dongle to enable wireless connectivity –– (6) USB 2.0 ports (2 USB ports in front, 4 USB ports
between the ultrasound system and the facility’s LAN to in the rear)
provide functionality equivalent to a wired network. –– DVI in/out
–– (2) AC Main Outlet

* At the time of publication, the U.S Food and Drug Administration has cleared ultrasound contrast agents only for use in LVO. Check current
regulations for the country in which you are using this system for contrast agent clearance.

15
ACUSON X700 Ultrasound System

Acoustic Output Management


Standards Compliance
• On-screen acoustic power indicator (AIUM/NEMA
output display standard) The ACUSON X700 system is in compliance with the
following standards, including all applicable amendments
System Dimensions at the time of product release.

• Height: 138.6 – 166 .3 cm (54.6 – 65.5 in) Quality Standards


• Width: 55.6 cm (21.9 in) • FDA QSR 21 CFR Part 820
• Depth: 90.5 cm (35.6 in) without rear handle, • ISO 9001
97.9 cm (38.5 in) with rear handle • ISO 13485
• Weight: 102 kg (225 lbs)
Design Standards
–– 98 kg (216 lbs) without OEM’s
• UL 60601-1
• CSA C22.2 No. 601-1
Electrical/Environmental • EN 60601-1 and IEC 60601-1
Specifications • EN 60601-1-1 and IEC 60601-1-1
The ACUSON X700 system is available in one mainframe • EN 60601-1-2 and IEC 60601-1-2 (Class B)
configuration, suitable for use in 100/115 V and 230 V • EN 60601-2-18 and IEC 60601-2-18
environments. • EN 60601-2-37 and IEC60601-2-37
• Power connections: 100-120/200-240 VAC, 50/60 Hz • EN 60601-2-25 and IEC 60601-2-25
• Built-in AC isolation transformer • EN 60601-1-4 and IEC 60601-1-4
• Power consumption: maximum 600 VA with OEM’s • EN60601-1-6 and IEC 60601-1-6
• Atmospheric pressure range: 700 – 1060 hPa • ISO 14971
(525 – 795 mm Hg) or up to 3000 m (9,483 ft) • EN 62304 and IEC 62304
• Ambient temperature range (without OEM’s): Acoustic Output Standards
10 – 40° C (50 – 104° F)
• IEC 61157 (Declaration of Acoustic Power)
• Humidity: 30 – 80%, non-condensing, during
• IEC 62359 ed. 2 (Test Methods for the Determination
operation
of TI and MI)
• Maximum heat output: 2150 BTU/hr
• AIUM/NEMA UD-2, Acoustic Output Measurement
• Average noise level output: 46 – 47 dB Standard for Diagnostic Ultrasound
• AIUM/NEMA UD-3, Standard for Real-time Display of
Integrating the Healthcare Thermal and Mechanical Acoustic Output Indices on
Diagnostic Ultrasound Equipment
Enterprise (IHE)
Having all relevant information at one’s fingertips is CE Declaration
a prerequisite for optimal and efficient patient care.
Seamless integration of the hospital’s IT and Imaging This product is provided with a CE marking
Systems and their capabilities to exchange information in accordance with the regulations stated
without restriction are key success factors for facilitating in Council Directive 93/42/EEC of June 14,
daily work. This is why Siemens has been instrumental 1993 concerning Medical Devices. The CE
in launching and advancing the IHE (Integrating the marking only applies to medical devices
Healthcare Enterprise) Initiative. Our commitment and that have been put on the market according to the above
dedication enable us to provide clinicians with the referenced Council Directive. Unauthorized changes to
ACUSON X700 system one of many innovative products this product are not covered by the CE marking and the
embedded with the building blocks necessary in support­ related Declaration of Conformity.
ing clinicians’ need for seamless health information
exchange.
For more information on the ACUSON X700 system and
the Siemens commitment to the IHE initiative, please visit
www.siemens.com/IHE.

16
ACUSON X700 Ultrasound System

EU Authorized Representative
Siemens AG
Healthcare
Henkestraße 127
91052 Erlangen
Germany
Phone: +49 9131 84 0

Siemens reserves the right to modify the design and


specifications contained herein without prior notice.
Please contact your local Siemens Healthcare Sales
Representative for the most current information.

17
The products/features mentioned in
this document may not be commercially
available in all countries. Due to regu­
latory reasons their future availability
cannot beguaranteed. Please contact
your local Siemens organization for
further details.

3-Scape, ACUSON X700, AcuNav,


Advanced SieClear, Axius, Cadence,
Clarify, DTI, DTO, Dynamic TCE, fourSight,
microCase, MultiHertz, Native, QuickSet,
SieClear, SieScape, SuppleFlex, SwiftLink,
TGO, and Velocity Vector Imaging are
trademarks of Siemens Medical Solutions
USA, Inc., and syngo is a trademark of
Siemens AG.

CartoSound and SoundStar are trade­


marks of BioSense Webster, Inc.

The product names and/or brands referred


to are the property of their respective
trademark holders.

Siemens Healthcare ­Headquarters Legal Manufacturer


Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc.
Henkestr. 127 Ultrasound
91052 Erlangen 685 E. Middlefield Road
Germany Mountain View, CA 94043
Phone: +49 9131 84-0 USA
siemens.com/healthcare Phone: 1-888-826-9702
siemens.com/ultrasound

CC US 2968 0716 online | © Siemens Medical Solutions USA, Inc., 2016

www.siemens.com/ultrasound

Das könnte Ihnen auch gefallen