Sie sind auf Seite 1von 44

circuit diagram ESD 15657 _03

product MSDF-A (with safety door)

plant MSDF-20A / MSDF-32A

customer MSDF-20A / MSDF-32A

customer no.
customer order no.
machine/
equipment-no.

date 07.05.2014 voltages wire colours regulations


user U.Stadelmann L1 3x 400 VAC black standards EN ISO 13849-1,EN 61439-1,EN 61439-2,EN 60204-1
examiner F. Züllig L2 50 cps black ambiente temperature around cabinet +5...+40°C
document type &EAA L3 black maximum temperature within cabinet
C5860 grid configuration relative humidity 50%
revision index change date name control VAC non-condensing (90% / 20°C)
3 Typenschild 11.05.2015 US neutral
Warning!
2 Kabel 04.02.2015 US earth green-yellow The cable cross sections are dimensioned according to the
1 Wägezelle 21.08.2014 US control AC 230 VAC red nominal current of the motors (and not according to the
common AC red-white setting range of the switches / circuit breakers). If more
associated documents powerful motors are employed, then the wiring must be
control DC 24 VDC blue
system diagram: AAAA-xxxxx altered in accordance with the above standards.
motor and apparatus list: AAAA-xxxxx common DC blue-white
external voltage orange
additional diagrams measuring line violet

© Copyright 2013. Title and all other rights in this document are reserved by Bühler AG, CH-9240 Uzwil

Bühler AG, CH-9240 Uzwil


1 2 3 4 5 6 7 8
number of pages description associated function associated equipment revision index document type
1 1 title page =A 3 &EAA
2 1 table of contents =A 0 &EAB
A 3 1 description of symbols =A 0 &EDB
A
4 1 description of symbols =A 0 &EDB
5 1 description of symbols =A 0 &EDB
6 1 description of marking =A 0 &EDB
7 1 Guideline for electrical installation =A 0 &EDB
8 1 Guideline for electrical installation =A 0 &EDB
9 1 description of marking =A 0 &EDB
10 1 description of marking =A 0 &EDB
50 1 terminal labelling =A 0 &EFS
B B
52 1 cable labelling =A 2 &EFS
90 1 overview + nameplate power cabinet +C2 =A +C2 3 &EFS
100 1 power supply =A +C2 0 &EFS
101 1 power supply 24VDC =A +C2 0 &EFS
150 1 safety door =A +C2 2 &EFS
160 1 emergency stop relay =A +C2 0 &EFS
200 1 MEAG baseboard =A +C2 2 &EFS
210 1 CAN display print operating unit +L1 =A +L1 0 &EFS
220 1 interfaces =A +C2 0 &EFS
C C
221 1 interfaces =A +C2 0 &EFS
250 1 CAN module, LC =A ++1 2 &EFS
260 1 load cell =A ++1 2 &EFS
300 1 supply servo drives 400V =A +C2 0 &EFS
310 1 servomotor dosing screw =A +C2 2 &EFS
320 1 servomotor agitator (optional) =A +C2 2 &EFS
330 1 servomotor hasp =A +C2 2 &EFS
3000 1 terminal diagram X1A +C2 =A +C2 X1A 0 &EMA
D 3001 1 terminal diagram X3BO +C2 =A +C2 X3BO 0 &EMA D
3002 1 terminal diagram X4AL +C2 =A +C2 X4AL 2 &EMA
4000 1 cable list =A 0 &EMB
4100 1 cable connection list 200W1 ++1 =A ++1 200W1 2 &EMB
4101 1 cable connection list 200W3 ++1 =A ++1 200W3 2 &EMB
4102 1 cable connection list 100W1 +C2 =A +C2 100W1 2 &EMB
4103 1 cable connection list 200W2 +C2 =A +C2 200W2 2 &EMB
4104 1 cable connection list 310W2 +C2 =A +C2 310W2 2 &EMB
4105 1 cable connection list 310W3 +C2 =A +C2 310W3 2 &EMB
E E
4106 1 cable connection list 320W2 +C2 =A +C2 320W2 2 &EMB
4107 1 cable connection list 320W3 +C2 =A +C2 320W3 2 &EMB
4108 1 cable connection list 330W2 +C2 =A +C2 330W2 2 &EMB
5000 1 device list +L1 =A +L1 0 &EPB
5001 1 device list +C2 =A +C2 0 &EPB
5002 1 device list ++1 =A ++1 2 &EPB
6000 1 I/O list +C2 =A +C2 0 &EFP

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A table of contents =A
&EAB
drawn U.Stadelmann Uzwil
checked F. Züllig Schweiz page 2
C5860 ESD 15657
rev. change date name orig. 2 replaces replaced by n.page 3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A
normally open contact NC contact delayed break on energizing rotary switch

normally closed contact (NC) NC contact delayed closing after de-energizing impulse-switch actuating on pull

B B
change-over contact thermal relay impulse push-button

power circuit breaker automatic circuit breaker emergency stop with locking

C C
normally open contact logging opening automatic circuit breaker with neutral disconnector key-switch stay-put contact

normally open contact logging closing power switch (3-phase) overload protection foot-operated switch stay-put contact

D D
normally closed contact logging opening normally open contact of a contactor (3-phase) impulse switch actuating on scan

normally closed contact leading opening circuit breaker NO-contact limit-switch contact open in position of rest

E NO contact delayed closing on energizing circuit breaker NC-contact limit-switch contact closed in position of rest E

NO contact delayed break after de-energizing stay-put actuating manually (general) rotary-switch with positions 1-2 (in pos. 1)

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A description of symbols =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 3
C5860 ESD 15657
rev. change date name orig. 3 replaces replaced by n.page 4
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A
coil, relay, contactor low-level probe transformer with connections and screen

coil of a timer delayed on de-energizing proximity switch

motor (3-phase)
B B
coil of a timer delayed on energizing AC/DC converter

delay circuit DC/DC converter motor

C C
overload release bridge rectifier signal lamp

electrothermal overload release thermo relay ammeter light emiting diode (LED)

D D
thermal relay (3-phase) voltmeter alarm horn (claxon)

undervoltage protection service-hour meter fuse

E electromagnetic permanent current valve pulse counter resistor E

pulse valve current transformer potentiometer

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A description of symbols =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 4
C5860 ESD 15657
rev. change date name orig. 4 replaces replaced by n.page 5
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A
inductance PLC control unit output potential cross reference

inductor with magnetic-core

PLC control unit input contact diagram


B B
capacitor

polar-capacitor (electrolytic, tantalum) pressure controller conductors crossing with connection

C C
R/C network (resistor / capacitor combination) temperature sensor conductors crossing without connection

diode earth, ground, protective -earth, -ground

pressure regulator

D D
terminal earth-, ground wire

connector pressure sensor mechanical linkage

E pin E
socket
thermistor, protective relay
empty
screw with external thread

screw with internal thread

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A description of symbols =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 5
C5860 ESD 15657
rev. change date name orig. 5 replaces replaced by n.page 6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Identification blocks B: type of operating means EN 81346-2


A A

A = touch screen Q = high-voltage switching equipment, power switches, contactors

B = converters from non-electrical to electrical quantities and vice versa R = resistors, potentiometers, diodes, inductances, chokes

B B
C = capacitors, storage devices S = switches, selectors, push buttons, command devices

A = designation of connections E = heating and lighting devices T = transformers, current transformers, amplifiers

B = type of operating means EN 81346-2

F = protective devices, circuit breakers, fuses U = mounting plate, isolators


C C = function of operating means C

D = counting number of operating means


G = fans, power supply equipment, generators, batteries V = filters (mechanically)

E = location of operating means

F = function EN 81346-1 K = relays, auxiliary contactors, timers, CPU, binary elements, tubes, W = transmission paths, leads, cables
transistors

D G = position of actuating operation means D

M = motors X = terminals, connectors, sockets, plugs, measuring and test terminals,


H = position of contact (sheet / path) coded plug

I= technical data
P = indicating devices (optical, acoustical), measuring and testing devices
(indicating, recording), counters
= = prefix for FUNCTION

++ = prefix for LOCATION (EXTERNAL)


E E

+ = prefix for LOCATION (INTERNAL)

-= prefix for OpERATING MEANS

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A description of marking =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 6
C5860 ESD 15657
rev. change date name orig. 6 replaces replaced by n.page 7
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Guideline for electrical installation


A A
If these guidelines are not followed, sufficient personal safety and interference
immunity cannot be ensured.
It is also mandatory to comply with the corresponding locally applicable electrical
installation requirements.
If the cables have to be installed in the same cable tray, the following
personal safety: possibilities exist
All electrical circuits must be routed in a way that is protected from external
mechanical damage.

interference immunitiy: example 2:


EMC = Electromagnetic Compatibility
B - observe a minimum distance of 5 cm (preferably use metal cable trays). B

1. separation of signal lines from power-voltage lines < 500 VAC

Cables with digital signal lines for direct current and cables with shielded analog
signal lines should preferably be installed in separate cable trays from those for digital signal lines for direct current,
power-voltage cables up to 500 VAC. analog signal lines, serial data
< 500 VAC or switched direct currents transmission lines

C example 1: C

< 500 VAC or switched direct currents

D D

example 3:

- Separate the cable groups with a metallic partition. The cable trays and the
partition must be electrically connected (for reasons of electromagnetic
interference and lightning strike protection).

digital signal lines for direct current, analog signal lines, serial data transmission
lines

digital signal lines for direct current,


analog signal lines, serial data
E < 500 VAC or switched direct currents transmission lines E

metallic partition

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A Guideline for electrical installation =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 7
C5860 ESD 15657
rev. change date name orig. 7 replaces replaced by n.page 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

- Signal lines should, if way possible, be separated from power-voltage cables < 500 V by
A different terminal boxes. At the very least, the feed-through bushings should be at separate
PLC or MCR unit PLC or MCR unit A
locations, and the terminals on the terminal strip should be separated from each other by at
least 2 cm.

analog or digital signal line

B Shielding by means of B
ground (earth) clip as
closely as possible to
power-voltage line < 500 VAC
cabinet entry point
(possibly near the PLC).
junction box terminals in distributor
box

2. separation of signal lines from power-voltage lines > 500 VAC


C C
Digital signal lines, analog signal lines and data transmission cables must be separated from
power-voltage cables > 500 VAC to 1000 VAC by a minimum distance of 10 cm, and from transducer transducer
power-voltage cables > 1 kVAC by a distance greater than 30 cm, preferably in separate
cable trays.

1) Only if specified in the schematic (shielding connected at both ends). If the shielding is
connected at both ends, a voltage equalization conductor may possibly have to be provided,
specially in case of greater distances or differing power supplies.

2) If a capacitive shielding connection is used at the MCR unit, the shielding must not be
3. analog signal lines grounded (shielding connected to appropriate unit terminal or plugin connector). In this case,
D no separate voltage equalization conductor is required. D
Analog signal lines must be installed with shielded cable. Connect the shielding according to
the sketch, at one end or both, depending on what is specified in the schematic. It is
preferable to use cable types with copper braid shielding. The inner conductors must be in
twisted pairs for the lead and return signal conductors.

4. motor cables

Motor cables with a high interference level, e.g. from


terminals Important! - frequency converters
shield connection short (< 3 cm) and signal - rectifiers
line separate from lines which can generate - timed DC motor controllers
E interference. E
must be installed shielded. The shielding must be connected as closely as possible to
ground (earth) at the control cabinet end.

shielding connection
Also on the motor side, the shield must be connected as short as possible to the chassis
(earth grounding connection). If the shield is only connected on the cabinet side to earth,
high emissions can be caused. If the motor lines are switched e. g. by a safety switch, the
shield must be wired over these elements as short as possible. If this is not possible,
exeptionally the shield can be connected on both sides to the chassis, because only the
radiation damages have to be blocked.

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A Guideline for electrical installation =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 8
C5860 ESD 15657
rev. change date name orig. 8 replaces replaced by n.page 9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

meaning of the notation of the designation 3. potential


A A
A letters A..Z, however without O and I AMA&MMMMMMMMMMMM (maximum 16 digits)

N numbers 0..9 AM code for potential


L1 rotary current phase 1
M letter or number
L2 rotary current phase 2
L3 rotary current phase 3
A1 control current AC voltage
A2 control current AC voltage earthed
D1 control current DC voltage
1. designation of the peripheral elements D2 control current DC voltage earthed
B F1 external voltage B
- equipment F2 external voltage earthed
B1 blinker
-NNNAN
T1 lamp test
- block designation for electrical equipment S1 collective fault
Mx Instrument leads (x=1..9: counting number for potentials belonging together
NNN electrical equipment number (page) such as measurement cells)
N neutral
A function designation, see table function of the electrical equipment
PE earth
N counting number
C A Counting letter for sources of potential on the same diagram page, beginning with A. C

& Block designation for reference to the diagram page where the source of potential is. If the
diagram page is purely numerical, & can be omitted.

2. designation system in a wiring diagram MMMMMMMMMMMM


Diagram page, where the source of potential is designated.
= plant
The plant designation corresponds exactly to that of the peripheral elements, regardless of where
the control panels are situated geographically.

D D
+ location

+ANNA

+ block designation for place of installation

A code of place of installation

C control panel or if both control and power sections are in 1 panel field

M motor control panel, motor starter panel


E L local control panel E
J marshalling box (more than approx. 10 terminals)
T terminal box (e.g. for level probes, up to approx. 10 terminals)
F field connection box

NNN panel number

A door designation or precise classification of the panel for machine control and devices

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A description of marking =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 9
C5860 ESD 15657
rev. change date name orig. 9 replaces replaced by n.page 10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

4. terminal bridge / plug


A A
The terminal bridge / plug is electrical equipment, according to DIN.

The block designation (-) is omitted.

XNMMMMM

X type of electrical equipment for terminal bridge / plug (maximum 8 digits, including block
designation)

N code for potential


B B
1 main current, power, drives, motors
2 control current AC
3 control current DC
4 instrument leads, analog signals
5 external voltage
6 free (e.g. for ammeter, generator)
7 free (e.g. for several potentials in one plug)
8 free
9 free
C C
MMMMM
free letters or numbers (however with maximum 3 consecutive letters or numbers)

additional guideline:
Terminal bridges and plugs which are connected 1:1 have the same designation.

D D

E E

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A description of marking =A
drawn
&EDB
U.Stadelmann
checked F. Züllig page 10
C5860 ESD 15657
rev. change date name orig. 10 replaces replaced by n.page 50
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

-X
B B

counter
potential source target
addition
0 A +L1 operating terminal (remote control) A +L1 operating terminal (remote control)
1 main power B +C2 power cabinet B +C2 power cabinet
2 control current AC C C
C C
3 control current DC D D
4 measuring line E E
5 external voltage F F
G G
H H
I I
D J J D

K K
L ++1 machine L ++1 machine
M M
N N
O ++9 plant external O ++9 plant external

E
P P
E
Q Q

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A terminal labelling =A
drawn
&EFS
U.Stadelmann
checked F. Züllig page 50
C5860 ESD 15657
rev. change date name orig. 50 replaces replaced by n.page 52
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

total number of wires incl. protective conductor

4 X numbered cable

B B

4 X PE numbered cable with protective conductor

4 X SCH numbered cable with shield

C C
4 X PE SCH cable numbered with protective
conductor and shield

4 X F coloured cable

4 X PE F coloured cabled with protective conductor


D D

4 X SCH F coloured cable with shield

wire colours IEC 757


BK = black
BN = brown
E RD = red E
OG = orange
YE = yellow
GN = green
BU = blue
VT = violet
GY = grey
WH = white
PK = pink
GD = Gold
TQ = turquoise
SH = shield
F F
2 Kabel 04.02.2015 US date 07.05.2014 MSDF-20A / MSDF-32A cable labelling =A
drawn
&EFS
0 Basisrevision 07.05.2014 us U.Stadelmann
checked F. Züllig page 52
C5860 ESD 15657
rev. change date name orig. 52 replaces replaced by n.page 90
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A

320MXZ1
Bühler AG, CH-9240 Uzwil agitator (optional)
EN 61439-1,EN 61439-2,EN 60204-1
Type: MSDF-A (with safety door)
No.: Built-in: 2015 Basic
Machine No.: protection
B B
Unit No.: +C2 Instructed
Diagram No.: ESD 15657 persons
U n(V AC ) fn(Hz) Ph I n A(A) P (kW)
400 50 3 11 4
IP 65 Ipk kA 50
+L1
210K1 operating unit
C C
150QYS1
door limit switch

cabinet: +C2

D D
600 mm

330MXZ1
100Q1
hasp (optional)
m
m0
30

600 mm

310MXZ1
dosing screw
E cable inlet: bottom E

F F
3 Typenschild 11.05.2015 US date 07.05.2014 MSDF-20A / MSDF-32A overview + nameplate power =A
&EFS
2 Kabel 04.02.2015 US drawn U.Stadelmann
cabinet +C2 +C2
0 Basisrevision 07.05.2014 us checked F. Züllig page 90
C5860 ESD 15657
rev. change date name orig. 90 replaces replaced by n.page 100
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

L1A100
/101.1A

L2A100
/101.1A
A A
L3A100
/101.1A

B B
1

100Q1
2

VCD-0

C C
PE

X1A
1

GND

D D
100W1
PE
L1

L2

L3

+L1
operating terminal
E supply E
3x 380-440VAC, 50Hz
current total: 11A
equipotential bonding
pre-fuse: <= 20A
max. short-circuit current Ipk: <= 50kA
elcb: <= 300mA

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A power supply =A
&EFS
drawn U.Stadelmann +C2
checked F. Züllig page 100
C5860 ESD 15657
rev. change date name orig. 100 replaces replaced by n.page 101
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

L1A100 L1A100
/100.8A /300.1A

L2A100 L2A100
/100.8A /300.1A
A A
L3A100 L3A100
/100.8A /300.1A

1
101F1
101F2
B GV2-RT05 4.00 A B
C60N

2
0.63 1.00 A
0.80 A I> I> I>

D1C101
101T1
2

QT5.241
5.00 A
L1 + D1C101
/150.1A

L2 +

D2C101
- D2C101
/150.1D

PE -
V
C C

D D

E E

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A power supply 24VDC =A
&EFS
drawn U.Stadelmann +C2
checked F. Züllig page 101
C5860 ESD 15657
rev. change date name orig. 101 replaces replaced by n.page 150
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D1C101 D1C101
/101.8B /160.1A

A A

/160.4C
S13

S14

S21

S22
A1

A1

X1

X2
150K1
B AES1235 B

13
23
K1

K2

14
24
A2

A2

Y1

Y2

C C

D2C101 D2C101
/101.8C /160.1D

D D
++1

4
WH
BU

BN
BK

E E

150QYS1
door limit switch

F F
2 Kabel 04.02.2015 US date 07.05.2014 MSDF-20A / MSDF-32A safety door =A
&EFS
0 Basisrevision 07.05.2014 us drawn U.Stadelmann +C2
checked F. Züllig page 150
C5860 ESD 15657
rev. change date name orig. 150 replaces replaced by n.page 160
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D1C101 D1C101
/150.8A /200.1A

A A

S32
A1

6
160K1

45
17
27
37
PNOZ S9C
200K1 X6
DI 0.6

18
28
38
46
.7C
24V = emergency stop OK

B settings: t[s]=1 / n=1 B


A2

S34

/200.1E

13

17
150K1 K1 160K1 K1
/150.1C .2B
K2 K2

C C

14

18
A1
160Q1

A2
LC1-D18BD
DI

D2C101 D2C101
/150.2D /200.1A
1 2
3 4
X3BO /300.4C

2
D 5 6 D
13 14

21 22

++1
160K1
1

attention! safety relay


E attention! do not change settings E
Safety related
SP
Part, adjusted

Do not remove seal / Plombe nicht entfernen


Plombe ne pas eliminer / no quitar el sellado

emergency stop system plant

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A emergency stop relay =A
&EFS
drawn U.Stadelmann +C2
checked F. Züllig page 160
C5860 ESD 15657
rev. change date name orig. 160 replaces replaced by n.page 200
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D1C101 D1C101
/160.8A /310.1B

D2C101 D2C101
/160.8D /310.1C
A A

X1

X1

X1
1

3
DI 0.0 DO 0.0

+24V
/221.1B /220.1B

PE
0V
200K1
DI 0.1 /221.2B DO 0.1
EKP-80263-810 DI 0.2 /221.3B DO 0.2
DI 0.3 /221.4B DO 0.3 /220.2B
DI 0.4 DO 0.4 /220.3B
DI 0.5 /221.5B DO 0.5 /220.4B
DI 0.6 /160.3A DO 0.6 /220.5B
DI 0.7 /221.6B DO 0.7 /220.6B
AI 0.0 DO 0.8
AI 0.1 DO 0.9
B LC DO 0.10 B
DO 0.11
AO 0.0
AO 0.1
X30
1 200W1 D1A200
26 25 +24V WH /210.1A
2 D2A200
0V BN /210.1A
3 RXT TXD+
RXD TXD + GN /210.1A
4 RXT TXD-
RXD TXD - YE /210.1A

C 2 1 C

X100
1
+24V
2 200W2 D2B200
0V WH /310.6C
3 CAN_H_200
CAN_H BN /310.6C
4 CAN_L_200
CAN_L GN /310.6C
SHB200
/310.6B

D D

PE
X4AL

4
++1

WH

GN
BN

YE
200W3
E SHC200 E
/250.1A
D1C200
/250.1A
D2C200
/250.1A
CAN_H2_200
/250.1A
CAN_L2_200
/250.1A

F F
2 Kabel 04.02.2015 US date 07.05.2014 MSDF-20A / MSDF-32A MEAG baseboard =A
&EFS
1 Wägezelle 21.08.2014 US drawn U.Stadelmann +C2
0 Basisrevision 07.05.2014 us checked F. Züllig page 200
C5860 ESD 15657
rev. change date name orig. 200 replaces replaced by n.page 210
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
+C2
D1A200
/200.8B
+C2
D2A200
/200.8B
A +C2
A
RXT TXD+
/200.8C
+C2
RXT TXD-
/200.8C

B B

X50

X50

X50

X50
1

4
DI 1

+24V

0V
210K1

R XD TX D -
RXD TXD +
+24V_Line +24V_EXT DI 2
EKP-80042-810 0V_Line 24V Input 1 DI 3
RXD_TXD+ Bus Term 24V Input 2
RXD_TXD- A=Off 24V Input 3
B=On
X50 X52
X54
C C

X51

X53

D D

E E

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A CAN display print =A
194820 &EFS
drawn U.Stadelmann
operating unit +L1 +L1
checked F. Züllig page 210
C5860 ESD 15657
rev. change date name orig. 210 replaces replaced by n.page 220
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

/200.1E /200.1E /200.1E /200.1E /200.1E /200.1E


alarm product feed aspiration device running preliminary tank empty low level bagging scale hopper operation
A A

200K1 X2 200K1 X2 200K1 X3 200K1 X3 200K1 X3 200K1 X3

GND DO 0.0 DO 0.3 DO 0.4 DO 0.5 DO 0.6 DO 0.7

GND

GND

GND

GND

GND
5

6
1

4
B B

C C

D D

++1

E E

alarm product feed aspiration device running preliminary tank empty low level bagging scale hopper operation

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A interfaces =A
&EFS
drawn U.Stadelmann +C2
checked F. Züllig page 220
C5860 ESD 15657
rev. change date name orig. 220 replaces replaced by n.page 221
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

/200.1E /200.1E /200.1E /200.1E /200.1E /200.1E


release, start dosing totaliser clear discharge refill scale reset alarm feeding: volumetric
A A

200K1 X5 200K1 X5 200K1 X5 200K1 X5 200K1 X6 200K1 X6


DI 0.0 DI 0.1 DI 0.2 DI 0.3 DI 0.5 DI 0.7
+ 2 4V

+ 2 4V

+ 2 4V

+ 2 4V

+ 2 4V

+ 2 4V
GND

GND

GND

GND

GND

GND
1

7
B B

C C

D D

++1

E E

release, start dosing totaliser clear discharge refill scale reset alarm feeding: volumetric

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A interfaces =A
&EFS
drawn U.Stadelmann +C2
checked F. Züllig page 221
C5860 ESD 15657
rev. change date name orig. 221 replaces replaced by n.page 250
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

SHC200
/200.8E

D1C200
/200.8E
A A
D2C200
/200.8E

CAN_H2_200
/200.8E

CAN_L2_200
/200.8E

WH

GN
BN

YE
B 200W3 B

X100

X100

X100

X100
1

4
CAN_L
+24V

0V

CAN_H
250K1 LC /260.4B DO 1.24
DI 1.24 DO 1.25
EKP-80118-810 DI 1.25 DO 1.26
DI 1.26 DO 1.27
DI 1.27 DO 1.28
DI 1.28 DO 1.29
C DI 1.29 DO 1.30 C
1 DI 1.30 DO 1.31
DI 1.31

X100

D D

E E

F F
2 Kabel 04.02.2015 US date 20.08.2014 MSDF-20A / MSDF-32A CAN module, LC =A
&EFS
1 Wägezelle 21.08.2014 US drawn U.Stadelmann ++1
checked F. Züllig page 250
C5860 ESD 15657
rev. change date name orig. 250 replaces replaced by n.page 260
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

/250.3D
load cell
A A

250K1
X301
LC

S H (S h ie ld )

S - (S en s e -)
S + S en s e +

O u t+ (5 V )

O u t- (0 V )
I+ (In + )

I- (In -)
1

7
B B

C C

D D

++1

7
1

5
WH
GN

GY
BU

RD
YE

E BK E

250BWE1
load cell

F F
2 Kabel 04.02.2015 US date 20.08.2014 MSDF-20A / MSDF-32A load cell =A
&EFS
1 Wägezelle 21.08.2014 US drawn U.Stadelmann ++1
checked F. Züllig page 260
C5860 ESD 15657
rev. change date name orig. 260 replaces replaced by n.page 300
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

L1A100
/101.8A

L2A100
/101.8A
A A
L3A100
/101.8A

5
300F1

GV2-P16

9.00 14.00 A
10.00 A I> I> I>
B B

6
1

5
160Q1
emergency stop OK
/160.7C

6
C C

D D

L1

L2

L3
300T1 PE

mains filter
NFD03.1-480-
016 PE

supply servo drives


L1.1

L2.1

L3.1
L1A110
/310.1A

L2A110
/310.1A
E E
L3A110
/310.1A

F F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A supply servo drives 400V =A
&EFS
drawn U.Stadelmann +C2
checked F. Züllig page 300
C5860 ESD 15657
rev. change date name orig. 300 replaces replaced by n.page 310
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

L1A110 L+A330
/300.8E /320.1A

L2A110 L-A330
/300.8E /320.1A
A strand cross-section at least 4 mm2/AWG12, twisted A
L3A110
/300.8E

M1A310
/320.4B

M2A310
/320.4B

B B

D1C101 D1C101 SHB200


/200.8A /320.1B /200.8D
D2B200
/200.8C
D2C101 D2C101 CAN_H_200
/200.8A /320.1C /200.8D
CAN_L_200
/200.8D

SC1
1
2
3
310X1
X13

X13

X77

X77

X47

X47
C C

X3

X3

X3
node

L+
L1

L2

L3

L-
1

6
750-963
310T1

M o d u lb u s
0V

+24V

M o d u lb u s G N D
ON OFF

4
5
6

SC2
X24
Multi Ethernet
IndraDrive Cs HCS01.1E-W0028-A-03-B-ET-EC-CN-NN-NN-FW 1 2 SHA310
/320.6B
X25 D2A310
Multi Ethernet 310W3 WH /320.6C
CAN_H_310
BN /320.6C
CAN_L_310
Encoder

GN /320.6C

M o tT e m p +

M o tT e m p -
A1

A2

A3

2
X5

X5

X5

X6

X6
PE

PE
D D
X4

GND
310W1

6
310W2

++1

E E

310BST1
1

1
PE
W
U

RX 310MXZ1 +
M
drive dosing screw 3AC
2

F F
2 Kabel 04.02.2015 US date 07.05.2014 MSDF-20A / MSDF-32A servomotor dosing screw =A
&EFS
0 Basisrevision 07.05.2014 us drawn U.Stadelmann +C2
checked F. Züllig page 310
C5860 ESD 15657
rev. change date name orig. 310 replaces replaced by n.page 320
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

L+A330 L+A330
/310.8A /330.1A

L-A330 L-A330
/310.8A /330.1A
A A

M1A310 M1A320
/310.8B /330.4B

M2A310 M2A320
/310.8B /330.4B

B B

D1C101 D1C101 SHA310


/310.3B /330.1B /310.8D
D2A310
/310.8D
D2C101 D2C101 CAN_H_310
/310.3C /330.1C /310.8D
CAN_L_310
/310.8D

SC1
1
2
3
320X1
X13

X13

X77

X77

X47

X47

X47

X47
C node C

L+

L-
1

6
750-963
320T1

M o d u lb u s

M o d u lb u s
0V

+24V

M o d u lb u s G N D

M o d u lb u s G N D
ON OFF

4
5
6

SC2
X24
Multi Ethernet
IndraDrive Cs HCS01.1E-W0005-A-03-B-ET-EC-CN-NN-NN-FW 1 2 SHA320
/330.6B
X25 D2A320
Multi Ethernet 320W3 WH /330.6C
CAN_H_320
BN /330.6C
CAN_L_320
Encoder

GN /330.6C

M o tT e m p +

M o tT e m p -
A1

A2

A3

2
X5

X5

X5

X6

X6
PE

PE
D D
X4

GND
320W1

6
320W2

++1

E E

320BST1
1

1
PE
W
U

RX 320MXZ1 +
M
agitator motor 3AC
2

F F
2 Kabel 04.02.2015 US date 07.05.2014 MSDF-20A / MSDF-32A servomotor agitator (optional) =A
&EFS
0 Basisrevision 07.05.2014 us drawn U.Stadelmann +C2
checked F. Züllig page 320
C5860 ESD 15657
rev. change date name orig. 320 replaces replaced by n.page 330
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

L+A330
/320.8A

L-A330
/320.8A
A A

M1A320
/320.8B

M2A320
/320.8B

B B

D1C101 SHA320
/320.3B /320.8D
D2A320
/320.8D
D2C101 CAN_H_320
/320.3C /320.8D
CAN_L_320
/320.8D

SC1
1
2
3
330X1
X13

X13

X77

X77

X47

X47
C node C

L+

L-
1

5
750-963
330T1

M o d u lb u s
0V

+24V

M o d u lb u s G N D
ON OFF

4
5
6

SC2
X24
Multi Ethernet
IndraDrive Cs HCS01.1E-W0005-A-03-B-ET-EC-CN-NN-NN-FW 1 2
X25
Multi Ethernet
Encoder

M o tT e m p +

M o tT e m p -
A1

A2

A3

2
X5

X5

X5

X6

X6
PE

PE
D D
X4

GND
330W1

6
330W2

++1

E E

330BST1
1

1
PE
W
U

RX 330MXZ1 +
M
drive hasp 3AC
2

F F
2 Kabel 04.02.2015 US date 07.05.2014 MSDF-20A / MSDF-32A servomotor hasp =A
&EFS
0 Basisrevision 07.05.2014 us drawn U.Stadelmann +C2
checked F. Züllig page 330
C5860 ESD 15657
rev. change date name orig. 330 replaces replaced by n.page 3000
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

external cable

internal cable
terminal strip X1A
number of terminal: 4
A A

terminal segment

terminal number
external destination internal destination

presentation
potential
type location function device connection location function device connection

jumper
wire
B GRAU,6 MM2,2L -NSHV L1 1 L1C100 100.1D 100Q1 2 B
GRAU,6 MM2,2L -NSHV L2 2 L2C100 100.1D 100Q1 4
GRAU,6 MM2,2L -NSHV L3 3 L3C100 100.2D 100Q1 6
GRÜN-GELB,6 MM2,2L,EEx PE 100.2D

C C

D D

E E

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A terminal diagram =A
&EMA
drawn U.Stadelmann
X1A +C2X1A
checked F. Züllig page 3000
+C2 C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 3001
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

external cable

internal cable
terminal strip X3BO
number of terminal: 2
A A

terminal segment

terminal number
external destination internal destination

presentation
potential
type location function device connection location function device connection

jumper
wire
B GRAU,2.5 MM2,3L ++1 emergency stop system plant 1 1 D1C160 160.4D 150K1 14 B
GRAU,2.5 MM2,3L ++1 emergency stop system plant 2 2 D1A160 160.4D 200K1 X6 DI 0.6 6

C C

D D

E E

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A terminal diagram =A
&EMA
drawn U.Stadelmann
X3BO +C2X3BO
checked F. Züllig page 3001
+C2 C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 3002
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

external cable

internal cable
terminal strip X4AL
number of terminal: 5
A A

++1 200W3

++1 200W3

CANBUS
200W2
terminal segment

terminal number
external destination internal destination

presentation
potential
type location function device connection location function device connection

jumper
wire
B GRAU,2.5 MM2,3L WH ++1 250K1 X100 1 1 D1B200 200.6D 200K1 CANopen X100 1 B
GRAU,2.5 MM2,3L BN ++1 250K1 X100 2 2 D2B200 200.6D 310X1 3 WH
200K1 CANopen X100 2
GRAU,2.5 MM2,3L GN ++1 250K1 X100 3 3 CAN_H_200 200.6D 310X1 2
200K1 CANopen X100 3
GRAU,2.5 MM2,3L YE ++1 250K1 X100 4 4 CAN_L_200 200.6D 310X1 1
200K1 CANopen X100 4
GRÜN-GELB,2.5 MM2,3L PE SHB200 200.7D 310X1 SC1 shield

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 11.05.2015 MSDF-20A / MSDF-32A terminal diagram =A
&EMA
1 Wägezelle 21.08.2014 US drawn U.Stadelmann
X4AL +C2X4AL
checked page 3002
+C2 C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 4000
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable target 1 target 2 material short description PE SH manufacturer type designation length Buhler number comment cross-reference

100W1 26826 1x10mm² 1 0 HELUKABEL H07V-K UNE-30013-026 Bühler Supply 4102.1A

310W3 +C2 310X1 +C2 320X1 81287 4x1x0.22mm²,SH 0 1 HELUKABEL CANBUS UXE-34544-050 4105.1A
A A
320W3 +C2 320X1 +C2 330X1 81287 4x1x0.22mm²,SH 0 1 HELUKABEL CANBUS UXE-34544-050 4107.1A

=A 200W2 +C2 310X1 +C2 200K1 81287 4x1x0.22mm²,SH 0 1 HELUKABEL CANBUS 2.00 m UXE-34544-050 200.7C 4103.

=A 310W1 ++1 310MXZ1 310BST1 +C2 310T1 X4 RKG4200/010.0 10.0M 0 1 RKG4200/010.0 10.00 m UNE-30522-012

=A 310W2 RKL0014/010.0 10.0M 1 1 RKL0014/010.0 10.00 m UNE-30522-129 310.3D 4104.

=A 320W1 ++1 320MXZ1 320BST1 +C2 320T1 X4 RKG4200/010.0 10.0M 0 1 RKG4200/010.0 10.00 m UNE-30522-012

=A 320W2 RKL0014/010.0 10.0M 1 1 RKL0014/010.0 10.00 m UNE-30522-129 320.3D 4106.

=A 330W1 ++1 330MXZ1 330BST1 +C2 330T1 X4 RKG4200/010.0 10.0M 0 1 RKG4200/010.0 10.00 m UNE-30522-012

=A 330W2 RKL0014/010.0 10.0M 1 1 RKL0014/010.0 10.00 m UNE-30522-129 330.3D 4108.


B B

C C

D D

E E

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A cable list =A
drawn
&EMB
U.Stadelmann
checked F. Züllig page 4000
C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 4100
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A ++1 200W1 BN +L1 210K1 X50 2 +C2 200K1 RS485_1 X30 2 0.5mm² brown 200.7B
=A ++1 200W1 GN +L1 210K1 X50 3 +C2 200K1 RS485_1 X30 3 0.5mm² green 200.7C

A =A ++1 200W1 WH 0.5mm² white 200.7B


A
=A ++1 200W1 YE +L1 210K1 X50 4 +C2 200K1 RS485_1 X30 4 0.5mm² yellow 200.7C
=A ++1 200W1 shield

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
200W1 ++1200W1
checked page 4100
rev. change date name orig. replaces replaced by
++1 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A ++1 200W3 BN +C2 X4AL 2 ++1 250K1 X100 2 0.5mm² brown 200.6E 250.5B
=A ++1 200W3 GN +C2 X4AL 3 ++1 250K1 X100 3 0.5mm² green 200.6E 250.5B

A =A ++1 200W3 WH +C2 X4AL 1 ++1 250K1 X100 1 0.5mm² white 250.4B 200.6E
A
=A ++1 200W3 YE +C2 X4AL 4 ++1 250K1 X100 4 0.5mm² yellow 200.6E 250.5B
=A ++1 200W3 shield 200.7E 250.4A 250.2A

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
200W3 ++1200W3
checked page 4101
rev. change date name orig. replaces replaced by
++1 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 100W1 GND +L1 PE_Potausgleich +C2 PE_Potausgleich 10mm² green-yellow 100.3D

A A

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
100W1 +C2100W1
checked page 4102
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 200W2 BN 0.22mm² brown 200.7D
=A +C2 200W2 GN 0.22mm² green 200.7D

A =A +C2 200W2 WH +C2 X4AL 2 +C2 310X1 3 0.22mm² white 200.7C


A
=A +C2 200W2 YE 0.22mm² yellow
=A +C2 200W2 shield +C2 X4AL PE +C2 310X1 SC1 310.6B 200.7D

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
200W2 +C2200W2
checked page 4103
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 310W2 1 +C2 310T1 X5 A1 ++1 310MXZ1 U black 310.3D
=A +C2 310W2 2 +C2 310T1 X5 A2 ++1 310MXZ1 V black 310.4D

A =A +C2 310W2 3 +C2 310T1 X5 A3 ++1 310MXZ1 W black 310.4D


A
=A +C2 310W2 5 +C2 310T1 X6 1 ++1 310MXZ1 1 black 310.4D
=A +C2 310W2 6 +C2 310T1 X6 2 ++1 310MXZ1 2 black 310.5D
=A +C2 310W2 7 black
=A +C2 310W2 8 black
=A +C2 310W2 GND +C2 310T1 PE ++1 310MXZ1 PE green-yellow 310.4D
=A +C2 310W2 shield

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
310W2 +C2310W2
checked page 4104
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 310W3 BN +C2 320X1 2 +C2 310X1 5 0.22mm² brown 310.7D
=A +C2 310W3 GN +C2 320X1 1 +C2 310X1 4 0.22mm² green 310.7D

A =A +C2 310W3 WH +C2 320X1 3 +C2 310X1 6 0.22mm² white 310.7D


A
=A +C2 310W3 YE 0.22mm² yellow
=A +C2 310W3 shield +C2 310X1 SC2 310.7D

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
310W3 +C2310W3
checked page 4105
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 320W2 1 +C2 320T1 X5 A1 ++1 320MXZ1 U black 320.3D
=A +C2 320W2 2 +C2 320T1 X5 A2 ++1 320MXZ1 V black 320.4D

A =A +C2 320W2 3 +C2 320T1 X5 A3 ++1 320MXZ1 W black 320.4D


A
=A +C2 320W2 5 +C2 320T1 X6 1 ++1 320MXZ1 1 black 320.4D
=A +C2 320W2 6 +C2 320T1 X6 2 ++1 320MXZ1 2 black 320.5D
=A +C2 320W2 7 black
=A +C2 320W2 8 black
=A +C2 320W2 GND +C2 320T1 PE ++1 320MXZ1 PE green-yellow 320.4D
=A +C2 320W2 shield

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
320W2 +C2320W2
checked page 4106
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 320W3 BN +C2 330X1 2 +C2 320X1 5 0.22mm² brown 320.7D
=A +C2 320W3 GN +C2 330X1 1 +C2 320X1 4 0.22mm² green 320.7D

A =A +C2 320W3 WH +C2 330X1 3 +C2 320X1 6 0.22mm² white 320.7D


A
=A +C2 320W3 YE 0.22mm² yellow
=A +C2 320W3 shield +C2 330X1 SC1 +C2 320X1 SC2 320.7D 330.7B

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
320W3 +C2320W3
checked page 4107
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 associated function 2 cable 3 core target 1 target 2 mm2/AWG wire colours cross-reference
=A +C2 330W2 1 +C2 330T1 X5 A1 ++1 330MXZ1 U black 330.3D
=A +C2 330W2 2 +C2 330T1 X5 A2 ++1 330MXZ1 V black 330.4D

A =A +C2 330W2 3 +C2 330T1 X5 A3 ++1 330MXZ1 W black 330.4D


A
=A +C2 330W2 5 +C2 330T1 X6 1 ++1 330MXZ1 1 black 330.4D
=A +C2 330W2 6 +C2 330T1 X6 2 ++1 330MXZ1 2 black 330.5D
=A +C2 330W2 7 black
=A +C2 330W2 8 black
=A +C2 330W2 GND +C2 330T1 PE ++1 330MXZ1 PE green-yellow 330.4D
=A +C2 330W2 shield

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 04.02.2015 MSDF-20A / MSDF-32A cable connection list =A
&EMB
drawn U.Stadelmann
330W2 +C2330W2
checked page 4108
rev. change date name orig. replaces replaced by
+C2 C5860 ESD 15657 n.page

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
location associated function device part of device Buhler number description type designation short description manufacturer cross-reference
+L1 =A 210K1 EKP-80042-810 Universalsteuerung EKP-80042-810 Display unit (EBD1316 Displayboard with foil) BÜHLER 210.3D

A A

B B

C C

D D

E E

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A device list =A
194820 &EPB
drawn U.Stadelmann
+L1 +L1
checked F. Züllig page 5000
C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 5001
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
location associated function device part of device Buhler number description type designation short description manufacturer cross-reference
+C2 =A 100Q1 UXE-24496-031 load-break switch VCD-0 25A,3-POL. SCHNEIDER ELECTRIC 100.1B
+C2 =A 101F1 UNE-24484-052 motor protection switch GV2-RT05 0.63-1A SCHNEIDER ELECTRIC 101.2B

A +C2 =A 101F2 UNE-22200-137 automatic circuit breaker C60N 1P, 4A, D, 10kA SCHNEIDER ELECTRIC 101.5B
A
+C2 =A 101T1 UNE-80210-005 power supply QT5.241 IN:2x380-480VAC,OUT:24-28VDC/5-4.3A PULS 101.3C
+C2 =A 150K1 UXE-36902-211 emergency stop switching unit AES1235 24VDC SCHMERSAL 150.1C
+C2 =A 160K1 UNE-36908-111 contact extension PNOZ S9C PILZ 160.2B
+C2 =A 160Q1 UNE-28007-021 contactor LC1-D18BD 24VDC;Hi 1xS/1xO SCHNEIDER ELECTRIC 160.7C
+C2 =A 200K1 EKP-80263-810 Universalsteuerung EKP-80263-810 EBD1312 MEAG Baseboard mit Montagematerial BÜHLER 200.1E
+C2 =A 300F1 UNE-24484-431 motor protection switch GV2-P16 9-14A SCHNEIDER ELECTRIC 300.4A
+C2 =A 300T1 UXE-13215-011 Netzfilter NFD03.1-480-016 16A BOSCH REXROTH 300.4E
+C2 =A 310T1 UXE-36078-007 Servoverstärker HCS01.1E-W0028-A-03-B-ET- IndraDrive Cs BOSCH REXROTH 310.2D
+C2 =A 310T1 UXE-36078-104 Firmware FWA-INDR*-MPB-17VRS-D5-1- Firmware zu Servoverstärker BOSCH REXROTH
B B
+C2 =A 310X1 UXE-36500-801 bus connection plug 750-963 FÜR CAN-OPEN WAGO 310.7C
+C2 =A 320T1 UXE-36078-005 Servoverstärker HCS01.1E-W0005-A-03-B-ET- IndraDrive Cs BOSCH REXROTH 320.2D
+C2 =A 320T1 UXE-36078-004 Zwischenkreisanschluss RLS0778/K06 18kW, 30A BOSCH-REXROTH
+C2 =A 320T1 UXE-36078-104 Firmware FWA-INDR*-MPB-17VRS-D5-1- Firmware zu Servoverstärker BOSCH REXROTH
+C2 =A 320X1 UXE-36500-801 bus connection plug 750-963 FÜR CAN-OPEN WAGO 320.7C
+C2 =A 330T1 UXE-36078-005 Servoverstärker HCS01.1E-W0005-A-03-B-ET- IndraDrive Cs BOSCH REXROTH 330.2D
+C2 =A 330T1 UXE-36078-004 Zwischenkreisanschluss RLS0778/K06 18kW, 30A BOSCH-REXROTH
+C2 =A 330T1 UXE-36078-104 Firmware FWA-INDR*-MPB-17VRS-D5-1- Firmware zu Servoverstärker BOSCH REXROTH
+C2 =A 330X1 UXE-36500-801 bus connection plug 750-963 FÜR CAN-OPEN WAGO 330.7C
C +C2 =A Aufnahmerahmen UNE-32030-011 Aufnahmerahmen CF16 CF16 Aufnahmerahmen CF16 ROXTEC C
+C2 =A D1C101 UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 101.5B
+C2 =A D2C101 UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 101.5C
+C2 =A Modul UNE-32030-022 Modul CM20W40 2x 3,5-16,5mm ROXTEC
+C2 =A Montageplatte WEA-10014-010 assembly plate WEA-10014-010 550x570mm BÜHLER
+C2 =A 1 X1A UNE-32201-131 terminal 282-901 GRAU,6 MM2,2L WAGO 100.1D
+C2 =A 2 X1A UNE-32201-131 terminal 282-901 GRAU,6 MM2,2L WAGO 100.1D
+C2 =A 3 X1A UNE-32201-131 terminal 282-901 GRAU,6 MM2,2L WAGO 100.2D
+C2 =A PE X1A UNE-32201-135 terminal 282-907 GRÜN-GELB,6 MM2,2L,EEx WAGO 100.2D
D +C2 =A 1 X3BO UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 160.4D D
+C2 =A 2 X3BO UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 160.4D
+C2 =A 1 X4AL UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 200.6D
+C2 =A 2 X4AL UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 200.6D
+C2 =A 3 X4AL UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 200.6D
+C2 =A 4 X4AL UNE-32201-111 terminal 280-681/999-941 GRAU,2.5 MM2,3L WAGO 200.6D
+C2 =A PE X4AL UNE-32202-531 terminal 280-687 GRÜN-GELB,2.5 MM2,3L WAGO 200.7D
+C2 =A cabinet: +C2 WEWS-10571-001 Schrank 600x600x300mm RAL 7035 BÜHLER 90.2E

E E

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A device list =A
&EPB
drawn U.Stadelmann
+C2 +C2
checked F. Züllig page 5001
C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 5002
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
location associated function device part of device Buhler number description type designation short description manufacturer cross-reference
++1 =A 250K1 EKP-80118-810 universal control EKP-80118-810 EBD1319 Can Modul LC, I/O BÜHLER 250.3D

A A

B B

C C

D D

E E

F page 1 of 1 pages
F
2 Kabel 04.02.2015 US date 11.05.2015 MSDF-20A / MSDF-32A device list =A
&EPB
1 Wägezelle 21.08.2014 US drawn U.Stadelmann
++1 ++1
checked page 5002
C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page 6000
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
device name 1 I/O 2 station number 3 address symbolic addressing comment associated function cross-reference

200K1 X8 AI 0.0 AI 0.0 =A

200K1 X8 AI 0.1 AI 0.1 =A


A A
200K1 X7 AO 0.0 AO 0.0 =A

200K1 X7 AO 0.1 AO 0.1 =A

200K1 X5 DI 0.0 DI 0.0 release, start dosing =A 221.1B

200K1 X5 DI 0.1 DI 0.1 totaliser clear =A 221.2B

200K1 X5 DI 0.2 DI 0.2 discharge =A 221.3B

200K1 X5 DI 0.3 DI 0.3 refill scale =A 221.4B

200K1 X6 DI 0.4 DI 0.4 =A

200K1 X6 DI 0.5 DI 0.5 reset alarm =A 221.5B


B B
200K1 X6 DI 0.6 DI 0.6 24V = emergency stop OK =A 160.3A

200K1 X6 DI 0.7 DI 0.7 feeding: volumetric =A 221.6B

200K1 X2 DO 0.0 DO 0.0 alarm =A 220.1B

200K1 X2 DO 0.1 DO 0.1 =A

200K1 X2 DO 0.2 DO 0.2 =A

200K1 X2 DO 0.3 DO 0.3 product feed =A 220.2B

200K1 X3 DO 0.4 DO 0.4 aspiration device running =A 220.3B

C 200K1 X3 DO 0.5 DO 0.5 preliminary tank empty =A 220.4B C


200K1 X3 DO 0.6 DO 0.6 low level bagging scale hopper =A 220.5B

200K1 X3 DO 0.7 DO 0.7 operation =A 220.6B

200K1 X4 DO 0.8 DO 0.8 =A

200K1 X4 DO 0.9 DO 0.9 =A

200K1 X4 DO 0.10 DO 0.10 =A

200K1 X4 DO 0.11 DO 0.11 =A

200K1 X10 LC LC load cell =A


D D

E E

F page 1 of 1 pages
F
0 Basisrevision 07.05.2014 us date 07.05.2014 MSDF-20A / MSDF-32A I/O list =A
&EFP
drawn U.Stadelmann
+C2 +C2
checked F. Züllig page 6000
C5860 ESD 15657
rev. change date name orig. replaces replaced by n.page -