Sie sind auf Seite 1von 27

V

Q 0.1527

Pi 3.14159265
ɸ int

ɸ int (m)
DN150 154.06 0.15406 178,410 79,135 13,189 131,892
DN250 254.51 0.25451 395,016 175,213 29,202 292,022
DN350 333.34 0.33334 630,763 279,781 46,630 466,302
DN450 431.80 0.4318 890,520 394,999 65,833 658,331
m/s
m³/s

(V) Velocidad Promedio


del Fluido (m/s)
m ɸ Nom ɸ int (m)
m DN150 0.15406 8.19161190770797
DN250 0.25451 3.0015076444355
DN350 0.33334 1.749743115905
DN450 0.4318 1.04275883861679

178,055
394,229
629,507
888,747
Re
ρ
V
ɸ int
µ

ɸ Nom

DN150
DN250
DN350
DN450
999.19 Kg/m³
m/s
m
0.001 Kg/ms

Numero de Reynolds
ɸ int (m) (V) Velocidad Promedio Regimen de Flujo (Re)

del Fluido (m/s)


0.15406 8.19161190770797 1,260,978
0.25451 3.0015076444355 763,295 Turbulento 4000 y superior
0.33334 1.749743115905 582,787 Laminar 0-2000
0.4318 1.04275883861679 449,899 Transiccion 2000-4000

Reepresenta regimen
de flujo, es una fuerza
que cambia el
regimen
No tiene dimension
000 y superior
1.359

ɸ Nom
DN150
DN250
DN350
DN450

353.678
Q 0.1527 m³/s 549.72 m³/h 0.54486722
DN150 154.06 mm
V 1
ɸ int (m) Re (Numero de Re Long. Entrada Hidrodinamica
0.15406 1,260,978 7.01594515697464
0.25451 763,295 10.223448264682
0.33334 582,787 12.516541357166
0.4318 449,899 15.1978006614187

Distancia en que se colocara la


bomba

app 40 a 45 veses el diametro interno


Acero al carbono cedula 40, (Rugosidad absoluta = 0.000045 m).

Solicita un ejemplo de calculo de cada uno de los calculos


ɸ int (m) Regimen de Flujo (Re) Factor de Friccion
1,260,978 0.15406 1,260,978 0.01545094
763,295 0.25451 763294.940479706 0.014689416
582,787 0.33334 582786.930165866 0.014574155
449,899 0.4318 449898.553268851 0.014661402
ρ Se asume igual a 1
g 9.8 m/s²
Lago abierto atmosfera
Tanque 1200 metros de altura que esta abierto a la atmosfera por lo tantP1=P2
Ecuacion Bernulli
Necesito calcular hL
Estructura Cantidad Descripción Valor kL
Tramo de tuberia recta 3800 Metros
Codos rectos 90° 90 Unidades 1.1
Codos rectos 45° 55 Unidades 0.4
Válvula de Compuerta (100% abierta) 1 Unidades 0.2
Válvula de Globo (100% abierta) 1 Unidades 10
Entrada Succion 1 Unidades 0.8
Salida Tuberia 1 Unidades 1
Sumatoria Perdida carga adsesorios (kL)
f = Factor de friccion
L= Largo total de la tuberia (m)
ɸ int (m) =Diametro interno
hL = Perdidas de Carga
kl= Perdidas de Carga de absosorisos de la tuberia
V= Velocidad (m/s)
g = Gravedad 9.8

(V) Velocidad
ɸ Nom ɸ int (m) Factor de Friccion Largo Tuberia (m) Promedio del Fluido
(m/s)
DN150 0.15406 0.01545094 3800 8.19161190770797
DN250 0.25451 0.014689416 3800 3.0015076444355
DN350 0.33334 0.014574155 3800 1.749743115905
DN450 0.4318 0.014661402 3800 1.04275883861679

Total kL
Consulta: Perdida de carga tuberia recta se calculan
99
22
0.2
10
0.8
1
133
risos de la tuberia

m/s²

(hL)Perdidas de
Carga

1760.10035690544
161.943406328772
46.727223115357
14.5363608172395
hL

Z2-Z1 = Altura de la 1200


ρ 999.19 Kg/m³
g 9.8 m/s²

Se considera diferencia de altura ( 1200


(hL)Perdidas de Carga Caida de presion en la tuberia
1760.10035690544 28985486.2210402 2960.10036
161.943406328772 13336234.2752625
46.727223115357 12208030.2658334
14.5363608172395 11892815.3463768 0
tuberia Caida de presion en la tuberia Caudal (Q) Potencia Bomba (N m)
DN450 28985486.2210402 0.1527 4426083.74595284
DN350 13336234.2752625 0.1527 2036442.97383259
DN250 12208030.2658334 0.1527 1864166.22159276
DN 150 11892815.3463768 0.1527 1816032.90339173
1 año 365 dias
65 dias mantencion 65 dias
dias de trabajo 300
Precio KWh 86
regimen de trabajo 24 horas

1 Nm 2.8E-07 kw hora

kw hora Costo dia Costo Año


1.2393034489 2557.92232 767376.695538319
0.5702040327 1176.90112 353070.337031199
0.521966542 1077.33894 323201.682834867
0.5084892129 1049.52174 314856.520658445
Tuberia Val.
6 metros Codo 90° Codo 45° Compuerta
($)/un ($)/ un ($)/ un ($)/ un
DN150 154.06 0.15406 178,410 79,135 13,189 131,892
DN250 254.51 0.25451 395,016 175,213 29,202 292,022
DN350 333.34 0.33334 630,763 279,781 46,630 466,302
DN450 431.80 0.43180 890,520 394,999 65,833 658,331

Codo 90° 90
Codo 45° 55
Val comp 1
Val Glob 1
Tuberia 633.333333 Tuberias
Distancia 3800 mts
Val. Globo Precio Precio Precio Val. Costos Precio Val. Costo total Ganancia 75%
($)/ un codos 90 Codos 45 Compuerta tuberia Globo proyecto materiales
178,055 $7,122,150 $725,395 $131,892 $112,993,000 $178,055 $121,150,492 $90,862,869
394,229 $15,769,170 $1,606,110 $292,022 $250,176,800 $394,229 $268,238,331 $201,178,748
629,507 $25,180,290 $2,564,650 $466,302 $399,483,233 $629,507 $428,323,982 $321,242,987
888,747 $35,549,910 $3,620,815 $658,331 $563,996,000 $888,747 $604,713,803 $453,535,352
Costo total neto costo
proyecto Costo proyecto con Iva mantencion Costo Año KW/h
$212,013,361 $ 252,295,900 $ 2,792,803 $ 314,857
$469,417,079 $ 558,606,324 $ 6,183,556 $ 323,202
$749,566,969 $ 891,984,693 $ 9,873,935 $ 353,070
$1,058,249,155 $ 1,259,316,495 $ 13,940,170 $ 767,377

Das könnte Ihnen auch gefallen