TERMINAL 12 L1 L2 UV FORM 6642 VT GROUP MP3101 NOT USED SEE PROTECTOFIER E FLAME RELAY (F) INTERCONNECTION FLAME-PAK SINGLE BURNER, MANUAL DIAGRAM BELOW ELECT. COIL IS ENERGIZED G NETWORK WHEN FLAME IS OPERATION, INCLUDES TIMER ESTABLISHED AND ACF FOR PURGE AND IGNITION DETECTED. TRIAL. D.C. ua TEST JACK 13 F 12 SS100A FLAME PAK LS 12 F 5 6 POC CTP1 (CHECK) ACF C - CHECK RELAY C ACF F - FLAME RELAY 1 4 PROOF OF 3 9 13 12 F CLOSURE SW. C ** POC - PROOF OF CLOSURE 1 7 1 7 TIMER CONTACT(S) FROM CTP2 C MAIN VALVE(S) START 1 4 3 10 4 TIMER 13 11 MOTOR CTP NO CONNECTION * 7 1
- JUMPER IN U300M MANUAL F 7 PURGED
* TIMOFIER FOR IGNITION TRIAL UNITS ONLY. 2 5 CTP3 (MUST BE NEON) SEE OFF-ON TIMING PURGE 12 ** - FUEL SAFETY INTLK.SERIES CIRCUIT. AND AIR PRESS.SWS., SCHEDULE IGN. F 11 6 C 4 IGNITION TRANS. VENT,FANS,ETC. AS REQ'D. IT NOTE: TIMER CAMS (CTP) SHOWN BURNER/ALARM 2 8 2 8 SPARK IN ZERO TIME POSITION. SEL.SW. IGNITOR CTP2 CLOSES BEFORE CTP1 OPENS. PILOT VALVE(S) PV
INTERNAL WIRING 9 F C 8 MAIN VALVE(S)
N.C. MV EXTERNAL WIRING 3 9 3 9 N.C. FLAME ON WIRING DIAGRAM (NEON LIGHT ON CHASSIS) F 10 AH 3 6 ALARM HORN
SINGLE BURNER PROTECTOFIER
NOTE: 120V. TERMINAL L1 MUST L1 (FORM 6642 VT GROUP MP3101) ua 50/60HZ. L1 D.C. BE POWERED BEFORE L2 TEST TERMINAL 12 FUSED L2 JACK LS FLAME POWER 3 PAK SUPPLY 4 U300M NOTES: PROOF OF MANUAL 5 G FLAME WIRE TO BE NO. 14 TYPE TW. ** CLOSURE SW. POC 6 TIMOFIER 600V. INSULATED WIRE OR EQUAL. FLAME TIMER 7 TRANS. WIRE MUST NOT BE IN SAME CONDUITS 8 WITH POWER WIRING. PURGED UV 9 IGNITION CABLE MUST BE RUN IN SEPARATE 10 CONDUIT TO SPARK ELECTRODE. BURNER/ ALARM 11 ACF ACF (DO NOT MIX WITH 120V.WIRING.) E OFF-ON 12 ALL WIRING AND EQUIPMENT EXTERNAL TO SEL.SW. 13 PROTECTOFIER TO BE FURNISHED BY (CHECK) (FLAME) OTHERS UNLESS OTHERWISE SPECIFIED. INSTALLATION, OPERATION AND MAINTENANCE FLAME ELECTRODE SHALL CONFORM WITH NATIONAL FIRE ASSY. (IF USED) FLAME OPERATING PROTECTION ASSOCIATION STANDARDS, WIRE SIGNAL BURNER E FROM NATIONAL AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION.ANY P-C II OR POC PURPLE UV FLAME MODIFICATION VOIDS APPROVAL. PROOF OF CLOSURE ROD CONTACT(S) FROM MAIN VALVE(S) GAS YELLOW PILOT START P-C II ULTRA- G P.B. VIOLET SCANNER U300M MANUAL (IF USED) ALARM HORN AH TIMOFIER TIMING RANGE PURGE(MIN.) IGN.(SEC.) IGN. TRANS. IT SPARK IGNITOR M MIN. SEC. IGN. CABLE MV PROTECTION CONTROLS, INC. N.C. MAIN VALVE(S) SKOKIE, ILLINOIS PILOT VALVE(S) PV WIRING DIAGRAM FOR: N.C. PROTECTOFIER FORM 6642VT GROUP MP3101 JOB NO. REVISED DRAWING NO. INTERCONNECTION DIAGRAM 1-05 X-379