VERSION HISTORY
===============
4. Reports now lay out text better on printers that refuse to use
Window's "Courier New" font and replace it with a variable width
font.
2. Comments on the same data file line as "Pipe", "Water", "Node", and
"Head" commands may be included in the 'notes' column of the 'pipe
information' and 'node analysis' sections.
3. A 'Check for update' option has been added to the 'help' menu.
8. Reynolds number for each pipe is now computed (but not used) with
Hazens-Williams friction loss formula calculations. The Reynolds number
calculation is based upon the currently selected liquid.
9. Fixed: editor's fitting proposal did not show valid fitting codes
defining K values only (not equivalent lengths).
10. Fixed: current file's liquid is now updated correctly if the liquid
is edited in the liquid editor.
1. Corrected reported head count when "system helper" commands are used.
1. Corrected an error with the water source static pressure to base of riser
adjustment when devices (Pump, BP, BFP commands) are used in pipes
oriented from remote area towards water source. This error affected the
hydraulic demand graph only and not calculated demand nor safety margin.
2. SHC now warns when a pump ("Pump" or "BP" command) is used in a piping
loop.
2. New file menu item "copy properties from" copies file properties from
an existing file to the current file.
3. Report footer now includes SHC version number. Pipe information section
now contains a statement about water flow direction.
Fixed:
1. Changing to another file from a current file using dxf import no longer
causes an access error.
Changes:
1. SHC Editor will now quickly change selected "Node" commands to "Head"
and vice versa. Menu items for this functionality has been added to
the "Edit"->"Change" menu.
2. SHC Editor will now quickly comment and uncomment selected lines.
Menu item for this functionality has been added to the
"Edit"->"Change" menu.
5. SHC will now allow data files that fail SHC's strict convergence test
to pass with a relaxed maximum unbalance requirement if calculated
unbalance is the only issue causing calculation failure.
6. Items #3, #4, and #5, taken together, measurably increase SHC's
calculation convergence success rate.
7. Nominal size text entity detection has been improved for DXF file
importing.
Fixed:
2. New warning highlighter colors values that SHC suspects may be in error
even when the value is technically valid. These warnings will not
prevent calculation.
5. Added file properties for overriding SHC Options of "System Designer" and
"Company". (See menu item "File" -> "Properties", "Project" tab.)
1. Fixed Pe unit conversion oversight in demand pie graph (menu item "View"
-> "Demand Graph") for mixed US & SI units files.
2. SHC no longer displays an erroneous warning when units are changed for
a file that uses equivalent k-factors.
3. In the hydraulic graph, the demand line's base point is now properly
adjusted for relative elevation difference to the water source when
the base of riser node name is not entered or is invalid.
4. The "Popup Helper" no longer suggests the wrong parameter type when
editing within a command line.
1. SHC's editor now allows "ChangePipe" commands to edit the extra pipes
created by the "Main" command when extra nodes are inserted.
4. Corrected dxf update error that could occure when updating from a DXF
source file that itself has been updated.
5. Corrected the insert menu's comment for Watts 709 backflow preventers.
Existing installations of SHC will not be updated, however, to
prevent overwriting user defined insert menu items.
1. The SHC editor no longer warning highlights ELO heads with a minimum
discharge pressure less than 10 psi. All heads now warn for minimum
discharge pressures less than 7 psi.
2. Corrected an error that kept some multiple source models from converging
on a solution.
5. The report's summary page entry "Total water required" now references the
supply analysis section when there are multiple water sources.
1. Corrected a report errata that could cause a criptic "List" error under
certain circumstances.
2. Fixed a "divide by zero" editor error when a zero k-factor was entered.
Zero k-factors will now shut off a head's discharge. ("Head" commands
only, not "Flow" commands.)
3. Fixed a demand graph error which occured when the water source has
negative head pressure.
2. Flow units of 'imperial gallons' & 'cubic meters per hour' are now
supported. This includes relevent k-factor units.
3. SHC now warns when reference node pressures and head discharge rates
are below specified minimums when performing a source calculation.
8. Default insert.txt file now includes entries for the Deringer model
backflow preventers from Backflow Direct. These curves have been
provided by Backflow Direct.
9. SHC now warns when flow exceeds the last flow value in a BFP,
BP, or PUMP command.