Sie sind auf Seite 1von 32

FUEL & OIL

FILTRATION

PETRO
petroind.com
www.
pet
roi
nd.
com

Table of Contents
3 Why Do I Need Clean Fuel?
4 What is Clean Fuel?
6 How Do I Get Clean Fuel?
8 Clean Diesel Kits
9 Clean Diesel Carts
10 Fuel and Lubricants Filters
12 Filter Heads
14 Manifolds
16 Bulk hP Filters and Heads
18 Clean DEF Filter
20 T.R.A.P.™ Breather
22 Reservoir Air Dryer
24 Accessories
26 System Sizing and Design
30 Filter Flow Rates and Pressure Drops

2 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
Why do I Need Clean Fuel?

DIESEL IS
As diesel travels from refinery

DIRTY.
to terminal locations to local bulk
storage and finally to your bulk
tank, it picks up contamination that
is deadly to today’s engines.

DIRT IS Your local distributor likely

BAD.
delivers diesel that meets or
exceeds fuel-industry standards for
cleanliness. This may not be clean
enough for your equipment.

REMOVE THE DIRT.


ACHIEVE
By filtering out dirt, water and other
contaminants before your fuel

MORE.
ever touches your equipment,
you’ll minimise costly downtime,
Keep Running and Achieve More.

GET A CLEAN SOLUTION.


To ensure that you’re pumping clean, dry fuel into your
equipment, call or email a Donaldson Clean Solutions expert.
No matter where you are or the size of your operation, there’s
a Clean Solution that will help you Achieve More.

petroind.com Clean Fuel & Lubricant Solutions • 3


What is Clean Fuel? www.
pet
roi
nd.
com

Achieving the Target


Cleanliness of a Fluid
ISO 4406 contamination codes are a way to
express fluid cleanliness. The three numbers RECOMMENDED
correspond to the number of particles ISO CLEANLINESS ISO 14/13/11
4 microns and larger, 6 microns and larger,
RATINGS Target rating for
and 14 microns and larger present in the fluid. diesel fuel
This page illustrates what it means to start
with a contamination of ISO 22/21/18 and
target a cleanliness of ISO 14/13/11.

ISO 4406 ISO 22/21/18


Typical cleanliness
ISO 16/14/11
Target rating for hydraulic/
CONTAMINATION CODES as fluid goes into transmission oils
your equipment
Range of number of particles per 100 milliliters
UP TO &
CODE MORE THAN INCLUDING
24 8,000,000 16,000,000 ISO
23 4,000,000 8,000,000 22 / 21 / 18
22 2,000,000 4,000,000 4 µm+
ISO 18/16/13
21 1,000,000 2,000,000 6 µm+
Target rating for heavy
20 500,000 1,000,000 gear/engine oils
19 250,000 500,000
18 130,000 250,000 14 µm+
17 64,000 130,000
16 32,000 64,000
15 16,000 32,000
14 8,000 16,000
13 4,000 8,000
12 2,000 4,000
11 1,000 2,000 ISO
10 500 1,000 14 / 13 / 11
9 250 500
8 130 250
4 µm+
7 64 130 6 µm+
6 32 64 14 µm+
5 16 32
4 8 16
3 4 8
2 2 4
1 1 2

4 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
What is Clean Fuel?

SIZES OF FAMILIAR
PARTICLES IN MICRONS
100 µm Grain of Table Salt
80 µm Human Hair
40 µm Lower Limit of Visibility
25 µm White Blood Cell
10 µm Talcum Powder
8 µm Red Blood Cell
2 µm Bacteria
<.5 µm Silt

Donaldson Delivers Choosing the


Water Protection Ideal Filters for
Are your bulk fluids passing large amounts of free water Your System
downstream – contaminating vehicles and equipment? Doesn’t Need to be
Donaldson’s water absorbing filter with super Complicated
absorbent polymer media, DBB0248, will

1
Select the right filter to achieve
stop flow if large amounts of free water are
targeted ISO cleanliness. Proper
detected in your ethanol-free fluids. Designing
design of the system will help avoid
systems with water absorbing filters requires
unnecessary costs.
careful sizing considerations. A Donaldson
specialist will assist in configuring a system
2
Determine the working pressure of
that meets your specific needs for flow and the system and select the filter
pressure drop. range compatible with that
pressure.

3
Different types of fluids have
different properties. Fluid viscosity
plays an important role in restricting
the flow through filters. Select a
filter that has compatible media-to-
fluid properties and will maintain
adequate flow and avoid excessive
pressure drops. See pages 30-31 for
filter flow rates and pressure drops.

petroind.com Clean Fuel & Lubricant Solutions • 5


How Do I Get Clean Fuel? www.
pet
roi
nd.
com

Donaldson Delivers

Superior Bulk Fluid Filtration


Lower Total Cost of Ownership Modular Solutions
Avoid Unplanned Downtime Compact Installation
Maximize Fuel Efficiency Low Inventory Costs
Low Installation Costs Easily Shipped
Custom Designs Easily Serviced

Clean. Protect.
Donaldson single-pass filtration on the inlet removes Water absorbing filters, T.R.A.P.™ Breathers and Reservoir
contamination before it can enter your storage tank Air Dryers reduce the risk of moisture and contaminants
and contaminate it. entering a bulk storage tank so fluids are kept clean and
dry. Used together, they’ll help guard fluids from free
Compact and easy to replace, Donaldson filters are an
water, airborne contamination and microbial growth for
important line of defense in maintaining fluid quality and
as long as they stay in storage.
can be configured for high flow rates while minimizing
pressure drop.

6 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
How Do I Get Clean Fuel?

P R OT E C
CLEAN T

POLISH
Polish.
Unstable fluids and the tank itself can be a source of
contamination. Final filtration on the outlet with Donaldson
filters ensures that targeted ISO cleanliness levels are
achieved before fluids are pumped into your equipment.

Achieve More.

petroind.com Clean Fuel & Lubricant Solutions • 7


Clean Diesel Kits www.
pet
roi
nd.
com

Clean Diesel Kits


Donaldson Clean & Dry Diesel Kits provide simple, effective outlet
filtration on fuel dispensers to allow you to pump clean fuel into your
vehicles and equipment.

These kits are easy to install on any fuel dispenser and come with
everything needed to filter out even the finest contaminants before
they can enter your equipment’s fuel system. With the included
easy-to-follow, step-by-step instructions, you’ll have effective,
efficient filtration in minutes.

P506073
Series Filtration
For flow rates up to
50 GPM / 189 LPM For complete
The Clean and Dry
Diesel Kit removes fuel
protection
contamination and stops We recommend installing a T.R.A.P.
water.This set uses two
Breather to keep airborne contamination and
high performance filters, in
moisture from entering your tank. Select
series, to clean your diesel
fuel ready for use. from one of the following;

Mobile Tanks

P5766645 - 3/4” BSP Anti-splash


X900018 P5766646 - 1” BSP Anti-splash
Series Filtration
For flow rates up to
100 GPM / 375 LPM Fixed Tanks to 1000 Litres

The Dual Head Clean P564669 - 1” NPT


and Dry Kit removes fuel P565616 - Bayonet
contamination and stops
water. This set uses two high
performance filter sets, in
series, to clean your diesel Fixed Tanks over 1000 Litires
fuel ready for use.
P923075 - T.R.A.P. Breather Filter
DFF0078 - T.R.A.P. Breather Assembly
See page 13 for Parallel and Series Filtration Flow Paths

8 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com Clean Diesel Carts

Off-Line Filtration
Donaldson provides off-line filtraion and fluid transfer
capabilities in convenient portable packages.

Use them in your workshop, with in-plant machinery,


or mobile equipment to achieve and maintain the ISO
cleanliness standard of your fluids.

Bu.F.S.S Bu.F.S.S. 12V B.O.S.S. B.O.S.S. Lite


Bulk Fuel Bulk Fuel Bulk Oil Bulk Oil
Service System Service System Service System Service System

Part Number P506057 X011408 P506037 P506081

DBB8666 Fuel Filter &


Replacement Filter Elements DBB8664 Oil Filter P565183 Bulk hP Filter
DBB0248 Water Absorbing Filter

DBB8777 Fuel Filter DBB8665 Oil Filter &


P565184 Bulk hP Filter
Optional Filter Elements DBB7733 Compact Fuel Filter DBB0248 Water
P565185 Bulk hP Filter
DBB5333 Compact Fuel Filter Absorbing Filter

Target ISO Cleanliness 14/13/11 or better 18/16/13 or better

Fluid Compatibility All diesel fuels Hydraulic, gear, transmission and engine oils

Micron Rating & Efficiency <4 micron @ Beta 2000 25 miron @ Beta 2000 14 micron @ Beta 2000

Water Absorbing Filter Stops all free and emulsified water (optional for P506037) n/a

240 Volt 50 Hz 240 Volt 50 Hz 240 Volt 50 Hz


Power Consumption 12V 35 Amp max
with 2m cable with 2m cable with 2m cable

63 lpm @ 2800 57 lpm @ 2900 40 lpm @ 1450 6 lpm @ 1450


Max. Flow Range
RPM RPM RPM RPM

Pump Vane pump Vane pump Gear pump Gear pump

H=1300mm H = 576mm H = 1300mm H = 430mm


Dimensions W = 550mm W = 521mm W = 550mm W = 435mm
D = 700mm D = 186mm D = 700mm D = 155mm

Weight 65 Kgs 34 Kgs 65 Kgs 14 Kgs

petroind.com Clean Fuel & Lubricant Solutions • 9


Fuel and Lubricants Filters www.
pet
roi
nd.
com

Fuel and Lubricants Filters


Donaldson Clean Solutions filters provide unsurpassed
cleanliness in a single pass. They are suited to inlet and
outlet filtration applications. Their spin-on design
enables fast and simple filter changes without special
tools and provides greater protection from
contamination during service than traditional cartridge
style filters.

The DBB range of elements incorporate advanced


technologies, providing excellent fluid compatibility
across a diverse range of operating environments.
Epoxy construction, E-coating and Viton® O-rings
ensure reliable sealing, maximum fluid compatibility
and corrosion resistance. Fuel elements utilise
Donaldson Electrostatic Reduction Tehchnology
(DERT) to manage the known effects of electrostatic
discharge.
Viton® is a registered trademark of E.I. DuPont de Nemours and Company.

FEATURES APPLICATIONS
• Highly efficient, state-of-the-art filter media and design • Single pass filtration for clean fluid transfers
• Unsurpassed filter efficiency • High efficiency kidney looping
• Cleans to target ISO cleanliness in a single pass • Inlet and outlet filtration at bulk storage tanks
• Modular design can be configured for • Dispenser “polishing” filtration on fuel pumps
virtually any flow rate or usage level and hose reels
• Fast and easy to service • Mobile and stationary applications

D.E.R.T.™
Donaldson Electrostatic Reduction Technology

Electrostatic discharge can be created when diesel fuel or light oils pass
through filter media at high flow rates.
The fluid being filtered may have inadequate conductivity to dissipate the
charge generated by high flow filtration applications. The electrical charge
can build-up in the fluid until it discharges or sparks across the filter,
burning holes in the filter media and letting through harmful contaminants.
Donaldson’s proprietary Electrostatic Reduction Technology neutralizes
Filter media damage from electrical charge and prevents damage to the filter media. This enables
Electrostatic Discharge (ESD). efficient single pass fuel filtration in high flow applications.

10 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
Fuel and Lubricants Filters

Compact Compact Water


Light Oil Heavy Oil
Fuel Filter Fuel Filter Fuel Filter Fuel Filter Absorbing
Filter Filter
Filter

Part Number DBB5333 DBB7733 DBB8666 DBB8777 DBB8665 DBB8664 DBB0248

Target ISO 14/13/11 14/13/11 Not


16/14/11 16/14/11 16/14/11 18/16/13
Cleanliness* or better or better Applicable

Micron Rating & 4 micron 7 micron 4 micron 25 micron Not


7 micron @ Beta 2000
Efficiency @ Beta 2000 @ Beta 2000 @ Beta 2000 @ Beta 2000 Applicable

Transmission
Fluid Engine and Ethanol-free
All diesel fuels and
Compatibility gear oil fluids
hydraulic oil

Recommended
< 100 cSt < 500 cSt < 6000 cSt <1500 cSt
Viscosity Range

Working
350 psi / 2413 kPa / 24.1 bar
Pressure

Element Collapse
150 psi / 1034 kPa / 10.3 bar
Pressure

Rated Static
800 psi / 5516 kPa / 55.2 bar
Burst

Max. Flow
32 gpm / 121 lpm 65 gpm / 246 lpm
Range**

D.E.R.T.*** Yes No

Nominal 5" x 7.5" / 5" x 14.25" /


Dimensions 12.7 cm x 19.1 cm 12.7 cm x 36.2 cm

-40 to
Operating
-40 to 245 °F / -40 to 118 °C 190 °F / -40 to 245 °F / -40 to 118 °C
Temperature
-40 to 88 °C
*
Select the proper filter by fluid type and OE recommended ISO code. Do not over-filter fluids. Doing so may result in the stripping of beneficial additive.
**
Actual flow rate varies based on fluid viscosity, pumping pressure and filter loading.
***
DERT ™ Donaldson Electrostatic Reduction Technology prevents media damage during high flow fuel applications.

See pressure drop/flow rate charts on page 30-31.

petroind.com Clean Fuel & Lubricant Solutions • 11


Filter Heads www.
pet
roi
nd.
com

Filter Heads
Clean Solutions filter heads feature robust, aluminum construction
with steel inserts to minimize metal-to-metal galling between
the head and the filter, even when used with diesel fuel.

The threaded insert contains an O-ring seal to completely seal the


clean side of the filter from the dirty side for maximum protection.
Viton® seals are compatible with a wide range of fluids and
maintain their integrity in cold weather.

For maximum cleanliness, use Clean Solutions filter heads


with Clean Solutions filters.
Viton® is a registered trademark of E.I. DuPont de Nemours and Company.

FEATURES APPLICATIONS
• Steel inserts are safe to use with diesel fuel • For use with Clean Solutions filters
• Threads contain an O-ring to completely seal • Compatible with all diesel fuels and lubricants
the clean side from the dirty side of the filter
• Heads are pre-ported for optional pressure
gauges and service indicators

Single Single Filter Head Dual Filter Dual Filter Head


Filter Head 11/4" NPTF Head 50psi Bypass Valve

Part Number P570329 P570330 P568583 P574958

11/2" SAE 4-Bolt 11/2” SAE 4-Bolt


Connection SAE-20 O-ring 11/4" NPTF
Code 61 Flange Code 61 Flange

Filter Quantity* 1 1 2 2

125 gpm /
Max. Flow Range** 65 gpm / 246 lpm
473 lpm

Fluid Compatibility All diesel fuels and lubricants

Working Pressure 350 psi / 2413 kPa / 24.1 bar

Rated Static Burst 800 psi / 5516 kPa / 55.2 bar

Operating
-40 to 245 °F / -40 to 118 °C
Temperature

Use to adapt pressure gauges or


Indicator Port
samping ports (sold separately)

Aluminum head with threaded


Materials
steel inserts and Viton® seals

DBB8664, DBB8665, DBB8666, DBB5333,


Compatible Filters
DBB0248, DBB8777, DBB7733
*
Filters sold separately
**
Actual flow rate varies based on fluid viscosity, pumping pressure and filter loading.

12 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
Filter Heads

Single Filter Head Filter Heads Pressure Drop


P570329 | P570330
Flow Rate (LPM)
0 100 200 300 400
12
0.8
127.8
[5.03]
35 40.1
[1.38] Single Dual 0.6
[1.58]
Head Head

Pressure Drop (BAR)


8

Pressure Drop (PSI)


47.8 DIRECTION
[1.88] OF FLOW 0.4

3/8 -16 UNC 4


4-PLACES
0.2

© Donaldson Company, Inc.


23.9
INDICATOR PORT [.94]

39.1
[1.54] 0 0.0
73.2 0 20 40 60 80 100 120
[2.88]
Flow Rate (GPM)

19.1 [0.75]
SAE-20 O-RING
or 1¼” NPTF

Dual Filter Head Pressure Drop


Flow Rate (LPM)
0 100 200 300 400
12
Dual Filter Head 0.8

P568583 | P574958
0.6

Pressure Drop (BAR)


8
Pressure Drop (PSI)

300.7
[11.84]
127.8 203.2
[5.03] [8.00] 0.4

DIRECTION 0.2

© Donaldson Company, Inc.


71.6 144.7
[5.70] OF FLOW
[2.82]

0 0.0
0 20 40 60 80 100 120
3/8 -16 UNC
4-PLACES Flow Rate (GPM)
INDICATOR
PORT 57.7
[2.27]

50.8
[2.00] Single Filter Head Pressure Drop
91.4
[3.60]
Flow Rate (LPM)
0 100 200 300 400
12
0.8
1 1/2” 19.05 [.75]
SAE 4-BOLT
CODE 61 FLANGE
0.6
Pressure Drop (BAR)

8
Pressure Drop (PSI)

0.4
Dual Head With
Parallel Flow Path 4

Single Head 2 Single Heads in Series 0.2


© Donaldson Company, Inc.

Flow Path Remove Dirt First, Then Water


0 0.0
0 20 40 60 80 100 120
Flow Rate (GPM)
Flow In Flow Out Flow In Flow Out Flow In Flow Out

petroind.com Clean Fuel & Lubricant Solutions • 13


Manifolds www.
pet
roi
nd.
com

Manifolds
Clean Solutions Filter Manifolds expand capacity or increase flow
rate beyond the capability of a single or dual filter head. Two or
more manifolds can be plumbed together to accommodate even
larger flow rates.

Manifolds split flow evenly between the individual filters. Fluid


passes through only one of the filters on its way across the manifold.
Dividing the flow between multiple filters plumbed in parallel reduces
the pressure drop through each filter.

The combination of Clean Solutions manifolds and filters ensure that


your equipment receives the cleanest possible fuel and oil.

4 Filter 8 Filter 10 Filter Inline 12


Manifold Manifold Manifold Manifold*

Part Number P561880 P568932 P568933 DFF1012

Filter Quantity** 4 8 10 Up to 12

2" ANSI
Mounting Connection 4" ANSI 150 Flange
150 Flange

250 gpm / 500 gpm / 1893 600 gpm / 2271 700 gpm / 2650
Max. Flow Range***
946 lpm lpm lpm lpm

140 lbs / 310 lbs / 390 lbs / 128 lbs /


Shipping Weight
64 kg 141 kg 177 kg 58 kg

Accessories
Pressure Gauges 2 pcs 0-160 psi / 0-11 bar gauges included
Sold Separately

Includes up-stream and down-stream mini-mess


Sampling
sampling ports with M16 x 2 thread

Fluid Compatibility All diesel fuels and lubricants

152 psi /
Working Pressure 1050 kPa /
10.5 bar

No external
Construction Painted carbon steel pipe with aluminum heads
aluminum

Compatible Filters DBB8664, DBB8665, DBB8666, DBB8777, DBB0248

Operating Temperature -40 to 245 °F / -40 to 118 °C


*
Inline 8 Manifolds are available upon request.
**
Filters sold separately
***
Actual flow rate varies based on fluid viscosity, pumping pressure and filter loading.

14 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com Manifolds

FEATURES APPLICATIONS
• Fast, easy and safe to service • Bulk fuel and lubricant filtration and water removal
• Requires no electrical or air hook-ups • High flow transfer into or out of tanks and dispensing equipment
• Large capacity in small footprint • Hard-to-filter high viscosity oils
• Flexible mounting options (horizontal or vertical) • Inline industrial filtration of gear oils and lubricants
• Cost effective high capacity system • Kidney loop applications

4 Filter Manifold
P561880 Manifold Pressure Drop
Flow Rate (LPM)
569.5 0 500 1000 1500 2000 2500
[22.42]
20

P561880
DOWNSTREAM 1.2
M16 X 2
DOWNSTREAM MINI MESS 16
M16 X 2 TEST PORT
MINI MESS 1

Pressure Drop (BAR)


TEST PORT
P568932

Pressure Drop (PSI)


444.5 P568933
[17.5] DFF1012
12
0.8

0.6
DIRECTION
8
OF FLOW

0.4

© Donaldson Company, Inc.


4
0.2

0 0
2” ANSI 150 2” ANSI 150 0 100 200 300 400 500 600 700
FLANGE FLANGE
Flow Rate (GPM)

8 Filter Manifold 10 Filter Manifold Inline 12 Manifold


P568932 P568933 DFF1012
621
[24.45] 569.5
[22.42] Blanking caps
and other 435.7

ANSI 150 FLANGE


accessories [17.15]

4" BORE see page 24-25

784.4
[30.88]
444.5
[17.5]

UPSTREAM
M16X2
MINI MESS
DIRECTION TEST PORT
OF FLOW 2X BLEEDER VALVES
DIRECTION
OF FLOW
UPSTREAM DOWNSTREAM DIRECTION 165.3
M16 X 2 M16 X 2 OF FLOW [6.51]
MINI MESS MINI MESS
TEST PORT TEST PORT
UPSTREAM DOWNSTREAM
M16 X 2 M16 X 2
MINI MESS MINI MESS
TEST PORT TEST PORT

746.8 416.8
[29.40] [16.41]

4” ANSI 150 4” ANSI 150


FLANGE FLANGE

4” ANSI 150 4” ANSI 150


FLANGE FLANGE
164.7
INDICATOR PORT [6.48]

UPSTREAM
150 M16X2
[5.91] MINI MESS
TEST PORT
114.3
[4.50]

petroind.com Clean Fuel & Lubricant Solutions • 15


Bulk hP Filters and Heads www.
pet
roi
nd.
com

Bulk hP Filters and Heads


Filtering oil prior to dispensing into equipment is critical to
meet the ISO cleanliness specifications demanded by today’s
OEM’s. Donaldson Bulk hP filters provide high efficiency filtration
in a single pass.

Service shops use high pressure pumps to force oil through long
lengths of piping and hose reels prior to dispensing into equipment.
Donaldson Bulk hP filters remove contaminants delivered in oil and
picked up in storage or delivery lines during final transfer. They
ensure the required ISO cleanliness level is met every time.

hP Single hP Head
Head with Bypass

Part Number P566023 P566024

Working Pressure 1000 psi / 6894 kPa / 68.9 bar

Indicator Yes

Yes - 50 psi /
Bypass Valve No
345 kPa / 3.4 bar

Connections SAE-16 O-ring

Bulk hP Bulk hP Bulk hP


Filter Filter Filter

Part Number P565184 P565185 P565183

Target ISO Cleanliness 14/13/11 16/14/11 18/16/13

Fluid Compatibility Petroleum based oils

Max. Flow Range 50 gpm / 189 lpm

Micron Rating & 4 micron 8 micron 14 micron


Efficiency @ Beta 2000 @ Beta 2000 @ Beta 2000

Working Pressure 1000 psi / 6894 kPa / 68.9 bar 800 psi / 5756 kPa / 55 bar

Element Collapse
300 psi / 2068 kPa / 20.7 bar
Pressure

Application Hydraulic, gear, transmission and engine oils

Rated Static Burst 2200 psi / 15,168 kPa / 151.7 bar 1700 psi / 11721 kPa / 117 bar

16 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com Bulk hP Filters and Heads

FEATURES APPLICATIONS
• Up to 1000 psi / 6894 kPa / 68.9 bar working pressure • Lube shops
• Extended life filters with high dirt holding capacity • Mobile service trucks
• Easy disposal with recyclable can and incinerable element • Other higher pressure single pass applications
• Compact design requires only 1.5" / 38 mm
clearance for servicing

Bulk hP Filter Heads hP Filter Head Pressure Drop


P566023 | P566024
Flow Rate (LPM)
114 0 25 50 75 100 125 150 175
[4.50] 20
34.9
[1.38] 1.2
16

Pressure Drop (BAR)


Pressure Drop (PSI)
119.8 12
[4.72] 0.8
34.9 DIRECTION
[1.38] OF FLOW

M10 X 1.5 X 11 0.4

© Donaldson Company, Inc.


4X
INDICATOR 4
PORT

35.1
[1.38]
66.5
[2.62] 0 0
109.5 0 10 20 30 40 50
[4.31]
19.0
Flow Rate (GPM)
SAE-16
[.75] O-RING

See pressure drop / flow rate curves on page 31.

Bulk hP Filters
P565184 | P565185 | P565183

94.1
[3.70]

250.8
[9.88]

CLEARANCE FOR
38.1 FILTER CHANGEOUT
[1.50]

THERMAL EXPANSION Donaldson highly advises following the pump


manufacturer’s relief recommendations. Pump manufacturers offer relief valves
to protect against over pressurization. A mere 10 °F / 5.5 °C increase in oil temp
can add 450 psi / 3103 kPa / 31 bar to the system while the pump is shut off.

petroind.com Clean Fuel & Lubricant Solutions • 17


Clean DEF Filter www.
pet
roi
nd.
com

Clean DEF Filter


Today’s Selective Catalytic Reduction (SCR) emissions control systems
require clean Diesel Exhaust Fluid (DEF) for precise dosing and complete
atomization to occur. However, contamination from transfer and storage or
corrosion from incompatible materials can prevent your SCR system from
getting the clean DEF it needs for proper operation.

The Donaldson DEF filter catches contaminants before they reach your
vehicle or equipment and the onboard DEF filter. Clean DEF ensures proper
function of the SCR and extends the life of the onboard DEF filter.

SCR

DEF

NOx Reduc
tion

DEF must be clean for proper dosing


to occur and turn NOx from exhaust
into harmless nitrogen and water
DEF PM Redu
Dosing ction vapor.
Module

DPF Pre-Filter
DEF Filter

P575058 1" BSPT


DEF Filter Housing Housing includes mounting
FEATURES bracket and filter wrench
• 1 micron at beta 5000 efficency DEF Filter Element P575059 sold separately
• 316 stainless steel housing
• Precise knife edge internal seal DEF Housing O-ring P575060 replacement part
• Heavy duty construction
Micron Rating & 1 micron @ Beta 5000
• Maximum working pressure (99.98%)
Efficiency
of 300 psi
• Leak-free O-ring seal Max. Flow Range 10 gpm / 38 lpm
• Integrated gauge/sample ports
Working Pressure 300 psi / 2068 kPa / 20.7 bar
• Replacement filters available
individually Operating Temperature 12 to 122 °F / -11 to 50 C°

Housing Construction 316 stainless, EPR O-ring

Filter Material Polypropylene, EPDM gaskets


APPLICATIONS
¼" NPT, upstream and
• DEF dispensers up to Indicator Port
downstream
10 GPM / 38 lpm
Drain Plug ¼" NPT

18 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com Clean DEF Filter

PART NUMBERS DEF Filter Pressure Drop


• P575058 DEF Filter Housing 1" BSPT Flow Rate (LPM)
0 5 10 15 20 25 30 35
• P575059 Clean DEF Filter 4

• P575060 DEF Housing Replacement O-ring 0.25

3 0.2

Pressure Drop (BAR)


Pressure Drop (PSI)
MOUNTING BRACKET 2
0.15

0.1

© Donaldson Company, Inc.


0.05

0 0
0 2 4 6 8 10
Flow Rate (GPM)

DEF Filter Housing


P575058

1/4-20 X 3/8” DEEP


1/4” NPT
DRAIN PLUG

87.9 48.3 38.1 87.9


[3.46] [1.90] [1.50] [3.46]

2X 1/4” NPT
GAUGE PORT

18.2
63.5 [.72]
[2.50] 347.7
[13.69]

CLEARANCE FOR
20.1 FILTER CHANGEOUT
[.79] 25.4
[1.00]

2 x 1” BSPT

104.8
[4.13]

Stainless steel pressure gauge not included –


must be sourced seperately.

DEF IS HIGHLY CORROSIVE. All pipe fittings must be compatible with DEF.
Most plastics as well as stainless steel are acceptable. Carbon steel, zinc,
aluminum, brass, copper, etc. are not recommended due to undesirable
chemical reactions. If any of these materials are used in your system they
should be immediately replaced with a compatible material.

petroind.com Clean Fuel & Lubricant Solutions • 19


T.R.A.P.™ Breather www.
pet
roi
nd.
com

T.R.A.P.™ Breather
The Thermally Reactive Advanced Protection (T.R.A.P.) Breather
assembly protects the fluids in your storage tank from airborne
particulate moisture contamination and ambient moisture.

It combines a high capacity 3 micron air filter with a deliquescent


breather that regenerates itself when air is expelled from the tank.
This self-regenerating capability of T.R.A.P. enables extended life
and functionality.

Keep your fluids clean and dry with a Donaldson T.R.A.P. Breather.

Tanks sizes above 10,000 gal. / 37,854 l. may require


multiple units and pressure vaccum relief valves.
Contact Donaldson for assistance.

T.R.A.P.
Breather

Assembly Part Number DFF0078

Efficiency 97% efficient @ 3 microns

Combined inlet and


Max. Flow Range outlet flow up to 500 lpm
maximum

Overflow Check Valve Opens at 2.32 psi / 15 kPa

-40 to 200 °F /
Operating Temperature
- 40 to 93 °C

Safe for use with all fuels


Fluid Compatibility
and lubricants

Indicator Standard mechanical

Height 16" / 410 mm


FUEL LEVEL DECREASES
ABS housing,
Construction
Urethane end caps

Connection 1½" BSP female

Replacement filter P923075 spin on

20 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com T.R.A.P.™ Breather

FEATURES
T.R.A.P. Breather Restriction
• High efficency air filtration Flow Rate (LPM)
• Longer life and lower airflow restriction than typical 0 200 400 600 800 1000 1200 1400
8
silica gel breathers
• Self-regenerating moisture adsorption 1.6
6
• Easy to service

Flow Restriction (in H2O)

Flow Restriction (kPa)


1.2

0.8

APPLICATIONS 2

© Donaldson Company, Inc.


0.4

• For use with all diesel fuels and lubricants


• Above and below ground tanks 0 0.0
0 100 200 300 400
• Mobile service trucks Flow Rate (GPM)

• Indoor or outdoor applications


Clean Pressure Drop Recommended flow rate
• Most tanks up to 10,000 gal. / 37,854 litres
(large tanks may require multiple units)

T.R.A.P. Breather
DFF0078
Ø176.5
[6.95]

D
MOIST AIR
RY

DRY AIR
AIR
MOIST AIR

Bulk Tank Breather &


Moisture Prevention

T.R.A.P TM

Replace per Indicator


(Maximum 4 months) 363
Installation date: [14.29]

SEPERATES HERE
FOR SERVICING

Always locate your tank’s name plate and cross


check against the flow chart above to ensure safety.
Use maximum flow INTO tank for validating pressure
rating and flow OUT OF tank for vacuum ratings.
DO NOT EXCEED TANK PRESSURE OR VACUUM. 1 1/2” BSP 105
CONNECTION [4.13]

petroind.com Clean Fuel & Lubricant Solutions • 21


Reservoir Air Dryer www.
pet
roi
nd.
com

Reservoir Air Dryer


The Donaldson Reservoir Air Dryer eliminates the need to continually replace
conventional desiccant breathers, enhancing reservoir breathing systems by
continuously purging and dehydrating reservoir headspace.

With no electrical requirements, the Donaldson Reservoir Air Dryer combats


ambient ingression of moisture by introducing a steady stream of clean, dry air to
the reservoir. This constant airflow helps sustain optimal conditions and prevents
the formation of condensation and rust in the reservoir, minimizing the potential for
particulate and water ingression through reservoir access points.

When combined with a T.R.A.P. Breather, the complete system keeps moisture and
contamination out, even if fluid flow rate out of the tank surpasses the Reservoir Air
Dryer flow rate into the tank.

Reservoir Air Dryer

Assembly Part Number P575852

Reduces dew point as much as


Efficiency
150 °F (83 °C)

Outlet Flow Volume @100 psi


0.5 scfm (14.2 slpm) maximum
and dew point suppression

Inlet Air required @ 100 psi 0.8 scfm (22.7 slpm) maximum

Pre-Filter Condition Visual Indicator (Green/Red)

Pressure Regulator Dial Gauge

Coalescer Drain Automatic Float Type

Max Working Pressure 116 psi (800 kPa / 8.00 bar)

Max Operating Temperature 125°F (52°C)

Petroleum and Phosphate Ester Fluids,


Fluid Compatibility
Diesel Fuels*

Inlet/Outlet Connection ¼” NPT

Mounting Bracket 3/8” - 16 UN Threaded Nut

Weight <5 lbs (<3 kgs)

Replacement Coalescing Pre-Filter

The Reservoir Air Dryer is not recommended for use on gasoline holding tanks or for the head space of any flammable liquid (Flash Point of 100F/38C)
*

22 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com Reservoir Air Dryer

FEATURES
• The clean, dry air sweep dehydrates the reservoir headspace and removes
dissolved moisture from exposed oils and fuels*
• Operates with standard plant air; instrument quality air is not required.
• Submicron coalescing air filter collects oil and water droplets and fine
particles from inlet air
• Automatic drain purges captured liquid with no intervention required
• Visual indicator monitors filter condition
• Membrane air dryer reduces plant air dew point by as much as 150 °F (83 °C)
• Pressure regulator depressurizes the air and ensures that the proper flow
rate of air is introduced into the reservoir

APPLICATIONS
• Lubricant system reservoirs
• Diesel storage tanks
• Oil storage tanks
• Gear boxes
• Hydraulic system reservoirs
The Reservoir Air Dryer is not recommended for use on
*

gasoline holding tanks or for the head space of any


flammable liquid (Flash Point of 100F/38C)

Reservoir Air Vent


P575852
3.5 in ( 8.9 cm )

AIR OUTLET
1/4" NPT

19 in (48 cm)

AIR INLET
1/4" NPT

petroind.com Clean Fuel & Lubricant Solutions • 23


Accessories www.
pet
roi
nd.
com

Accessories
PARTS
Part Number Description Application

DFF1005 I-12 Blanking Cap Blank off up to 6 orifices on I-12 manifold for flush mounting

Allow unfiltered flow through manifolds during site


P506070 Commissioning Cap
commissioning

4-Bolt Code 61 Flange to 1½" BSPP Adapter


P506071 Adapts P568583, P574958 Dual Head to 1½" BSPP
¼”BSP, ¼” NPT ports (plugged)

P573642 Threaded Pipe Nipple 11/4" NPT, for connecting two P570330 single heads in series

Replacement O-rings for heads and manfiolds, Viton,


P164050 Threaded Insert O-rings
not for use on hP

Small oil tanks under 250 gal. / 1000 liters, 1" NPT,
P564669 ABS Breather, 3 Micron
splash containment for mobile applications

P506076 SAE 20 O-ring 1” BSPT Male Adapts P570329 Single filter head to 1” BSPT male

PRESSURE GAUGES AND SERVICE INDICATORS


Part Number Description Application

Use with all Clean Solutions heads and manifolds,


P174396 Electrical Service Indicator 50 psi / 345 kPa / 3.45 bar
microprocessor compatible

P574177 Visual Service Indicator 50 psi / 345 kPa / 3.45 bar For single heads and hP heads, industrial grade green to red

P165965 Visual Service Indicator 25 psi / 172 kPa / 1.72 bar For single heads and hP heads, industrial grade green to red

P573682 Upstream Pressure Gauge Adapter For single and dual heads, 1/8" NPT

For single and dual heads, 1/8" NPT, center back mount,
P573681 Pressure Gauge, 0 – 60 psi / 414 kPa / 4.1 bar
1½" diameter, use with P573682 adapter

For Clean Solutions manifolds, M16 x 2 to 1/4" NPT


P563809 Direct Gauge Adapter
adapter, use to mount pressure gauge to test point

For Clean Solutions manifolds, stem mount,


P562709 Pressure Gauge, 0 -160 psi / 1103 kPa / 11.0 bar
2½" diameter, use with P563809 adapter

24 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
Accessories

SAMPLING TOOLS
Part Number Description Application

For single, dual heads, and hP heads, SAE-4, use with


P573414 Upstream Sampling/Indicator Port Adapter
P563224 for sampling

For single, dual heads, and hP heads, SAE-4, use with


P573415 Downstream Sampling/Indicator Port Adapter
P563224 for sampling

For use with P573414 and P573415 adapters


P563224 Test Point
SAE-4 to M16 x 2

P563212 Test Point For all Clean Solutions manifolds, 1/8" NPT to M16 x 2

P563215 Test Point For dual heads, ¼ BSPP to M16 x 2, use with P506071
flange, P506037 B.O.S.S. and P506057 Bu.F.S.S.

1620 series M16 x 2 thread, for use with P563212,


P563250 Test Point Hose Assembly, 12"
P563215 and P563224 mini mess test points

1620 series M16 x 2 thread, for use with P563212,


P563215 Test Point Hose Assembly, 1220mm
P563215 and P563224 mini mess test points

TEST KIT
Part Number Description Application

X009329 Patch Test Kit Test kit for measuring fluid cleanliness

P567869 0.8 Micron Membrane Filter Spares for Patch Test Kit, purchase in multiples of 100

P567860 Solvent Dispensing Filter Spares for Patch Test Kit, purchase in multiples of 1

P567865 Analysis Cards Spares for Patch Test Kit, purchase in multiples of 50

P567861 120 ml Sample Bottle Spare for Patch Test Kit

petroind.com Clean Fuel & Lubricant Solutions • 25


System and Sizing www.
pet
roi
nd.
com

The Importance of Temperature in


Sizing Your Filtration System
Fluid viscosity, measured in centistokes (cSt) or Saybolt Seconds
Universal (SSU or SUS), is the resistance of a fluid to flow (thickness of
fluid). Low viscosity fluids pass through filters with less resistance than
high viscosity fluids. Higher fluid viscosities have higher pressure drops
due to higher resistance passing through the media.

The colder the fluid, the higher the viscosity, so the lowest potential
WATER HONEY
temperature of the fluid during filtration is the best measure for sizing
a bulk filtration system. Due to the high specific heat capacity of fluids, Temperature greatly impacts fluid
viscosity. Consider that ISO 32
the lowest ambient temperature may not be an accurate reflection of the oil at 104 °F / 40 °C has the same
actual fluid temperature. Avoid oversizing your system by using the stored viscosity as diesel fuel (similar to
water). When temperatures drop
fluid temperature and not the lowest ambient temperature, which tends to
to -4 °F / -20 °C, the viscosity
be lower than the temperature of the fluid in storage or transport. of that ISO 32 oil increases
dramatically to over 2,000
centistokes, which is similar to
honey at room temperature.

FUEL/OIL KINEMATIC VISCOSITY


COMBINED WITH TEMPERATURE IN CENTISTOKES CST
SAE Gear Oil 75W 80W 85W 90 140
SAE Engine Oil 5W 10W 20 30 40 50
ISO Grade 15 22 32 46 68 100 150 220 320 460 680
°F °C Diesel
248 120 4 4 6 7 9 12 13 18 23
230 110 4 6 7 9 12 15 19 24 30
212 100 1 5 5 7 9 11 15 19 25 32 41
194 90 3 5 7 9 11 15 20 26 34 44 58
176 80 5 7 9 11 15 20 27 36 48 63 85
158 70 6 9 11 15 20 28 39 52 71 95 130
140 60 8 12 15 21 29 40 57 80 110 151 211
122 50 11 15 22 30 43 62 99 128 181 254 365
104 40 1 15 22 32 46 68 100 150 220 320 460 680
86 30 2 21 32 51 76 116 175 271 409 613 907 1,380
68 20 3 33 51 87 135 214 334 536 838 1,290 1,980 3,130
50 10 4 52 87 162 264 438 711 1,190 1,920 3,070 4,870 8,020
32 0 5 85 180 340 585 1,020 1,720 2,990 5,060 8,400 13,900 23,900
14 -10 9 185 375 820 1,500 2,770 4,880 8,890 15,700 27,200 47,000 85,000
-4 -20 15 400 800 2,350 4,650 91,20 16,800 32,300 60,000

26 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
System and Sizing

Bulk filtration systems must be designed


properly to meet the desired ISO cleanliness
code while maintaining the existing flow rates.
The filter type and quantity of filters varies
based on the desired cleanliness, system
pressure and flow rate.
Increasing the flow rate will increase the pressure drop across a filter. If the pressure
drop is too high, system flow rate can be reduced or damage to the filter can occur.
To reduce the pressure drop, increase the number of filters in the system.

The chart below demonstrates the pressure drop experienced by a filter with
various viscosities and flow rates. The steeper the pressure drop curve, the more
filters that must be added to the system. Additional filters plumbed in parallel will
decrease the flow rate per filter, lowering the pressure drop and allowing existing flow
rates to be maintained.

uel Filter DBB8664 - Heavy Oil Filter


Flow Rate (LPM)
100 120 0 50 100 150 200
40
3.2 6000
cSt 2.5
2.8 3000 1500 750 500
cSt cSt cSt cSt
More 30
2.0
2.4
Filters
Pressure Drop (BAR)

Pressure Drop (BAR)


Pressure Drop (PSI)

2.0 250
32 1.5
cSt cSt
20
1.6

1.0
Fewer
1.2

Filters
0.8 10
© Donaldson Company, Inc.

© Donaldson Company, Inc.

0.5
3
cSt 0.4

0 0 0.0
25 30 35 0 10 20 30 40 50 60
Flow Rate (GPM)

l Filter DBB0248 - Water Absorbing Filter


petroind.com Clean Fuel & Lubricant Solutions • 27
Flow Rate (LPM)
150 200 0 50 100 150 200
System and Sizing www.
pet
roi
nd.
com

Steps to Sizing a Bulk Application

1 2
Define product flow rate, fluid type and Use the table on the page 26 to
pressure drop restriction. New systems determine fluid viscosity using the fluid
should ideally have the lowest practicable type and temperature.
pressure drop.

INFORMATION GATHERING
FLOW RATE:
FLUID TYPE:
PRESSURE DROP:
TEMPERATURE:

28 • Clean Fuel & Lubricant Solutions petroind.com


www.
pet
roi
nd.
com
System and Sizing

3 4
Select the appropriate filter based Determine the filter pressure drop using
on desired ISO cleanliness code and the flow rate and the fluid viscosity
working pressure (see pages 10 and 11). according to the appropriate chart on pages
30 – 31. Add the manifold pressure drop
using the flow rate on page 15 to calculate
total pressure drop.

Divide total pressure drop through one filter


You Don’t Need by the desired system pressure drop. This
To Do It Alone. number is equal to the quantity of filter
required to clean the fluid properly at the
Let a Donaldson specialist assist determined flow rate. If the pressure drop is
you by providing recommendations more than 10 psi / 0.69 bar, go up one size.
on sizing, selection and positioning
of Donaldson filters. You can help CALCULATED
us design your system by providing:

Responses to steps 1-4 above.


PRESSURE DROP
DESIRED
=
PRESSURE DROP
A schematic of your fluid transfer
process (hand sketches work
great), and/or

Photographs of your site (tanks,


inlets and outlets).

Just call 1800 FILTER (345 837)


to get started.

petroind.com Clean Fuel & Lubricant Solutions • 29


DBB8665 - Light Oil Filter DBB0248 - Water Absorbing Filter
DBB5333 - Compact Fuel Filter
DBB8665Flow- Light
Rate (LPM)Oil Filter DBB0248 - Water Absorbing Filter
Flow Rate (LPM)
0 50 100 150 200 Flow Rate (LPM)
0 50 100 150 200
Flow Rate (LPM) Flow
60 Rate (LPM) 0
40 40 0 20 40 80 100 120
0
3000 50 100 150 200 50 1500
0 50 100 150 200 40
40 cSt 2.5 40 cSt 2.5
3.2 6

Flow Rates and Pressure Drops


3000 1500 750 500 1500
cSt cSt 250 250 150
cSt cSt cSt 2.5 cSt 750 2.5
750 500 200 cSt cSt cSt 2.8
30 1500 250 40
30
cSt cSt cSt cSt 2.0 750 www.
pet
r 250
oi
nd.c
om 150 2.0 30
cSt cSt cSt
30 200 cSt 2.4
30

(BAR)(BAR)

(BAR)
cSt 2.0
(PSI) (PSI)

(PSI) (PSI)
2.0

(BAR)
Drop (PSI)

Pressure Drop (PSI)


30 90
1.5 2.0
cSt 1.5

Pressure Drop (BAR)


Drop Drop

32

Drop Drop
Drop Drop

Drop
20 20
150 cSt

Drop
90 20
cSt 1.5 cSt 1.61.5
Pressure

Pressure
Pressure
20

Pressure
20
150

Pressure
1.0 20

Pressure
1.0
cSt 32 1.2
Pressure

Pressure
Pressure
Flow Rates and Pressure Drops
10 1.0 cSt
10 1.0

© Donaldson Company, Inc.


10

Inc.
320.8

Inc.
0.5 1010 cSt0.5

Company,
10

Company,
3

© Donaldson Company, Inc.

© Donaldson Company, Inc.


3 cSt
0.5 cSt (Diesel) 0.40.5

Donaldson
0 0.0 0 3 cSt 0.0

Donaldson
FUEL AND WATER ABSORBING FILTERS 0 10 20 30 40 50 60 0 (Diesel) 0 0
00 510 10 20 15 30 20 40 25 5030 60
35 0
0 0.0 0 0.0

©©
Flow Rate (GPM) Flow Rate (GPM)
0 10 20 30 40 50 60 0 10 20 Flow Rate30(GPM) 40 50 60
Flow Rate (GPM) Flow Rate (GPM)

DBB8777--Compact
DBB5333 Winter Fuel Filter
Fuel Filter DBB8666--Heavy
DBB8664 Fuel Filter
Oil Filter
DBB8777 -Flow
Winter
Flow Rate Fuel Filter
(LPM)
Rate (LPM) DBB8666
DBB8665 -Flow
Flow -Rate
Light
Rate Fuel
(LPM)
OilFilter
(LPM) Filter
00 20 50 40 10060 80150 100 200 120 0 0 50 50 100100 150 150 200 200
40
50 Flow Rate (LPM) 40 40 Flow Rate (LPM)
1500 750 250 Flow Rate (LPM)
0 50 cSt 100 150 200 1500 6000
750 250
cSt cSt 2.53.2 00 cStcSt
cSt
50
50
cSt
100
10090 150
150 60
200
200 2.5 2.5 0
40 40 cSt cSt
1500 40 40
750 cSt 250 1500 7503000 250 750
90
150 cSt 2.8 3000 1500 500 1
40 cSt cSt 2.5 cSt 60
30 cSt
30 30
cSt cSt cStcSt cSt
cSt cSt
cSt 2.52.5
2.0 1500 750 500 2.0 2.0
2.4 cSt cSt 250
150 cSt cSt cSt

Drop (BAR)
30 32

Drop (BAR)
(PSI)

30 200

Drop (PSI)
(BAR)

Pressure Drop (BAR)


2.0 30 30
Drop(PSI)

Pressure Drop (PSI)


30 cSt
cSt 2.02.0
32 90 cSt 1.52.0 250 1.5

(BAR)
20 32 1.5

Pressure Drop (BAR)


(PSI)

20 cSt

(PSI)
DropDrop

cSt

Drop (BAR)
DropDrop

Drop(PSI)

Pressure Drop (PSI)


20 20cSt
1.6 cSt
1.5
Pressure

90 cSt 1.51.5

Pressure
Pressure

Pressure
Pressure

20

Drop
20 1.0
Pressure 20
20 1.0 20
1.2 20
150 1.0
cSt
cSt
Pressure

32 cSt

Pressure
Pressure

Pressure
10

Pressure
1.0 10
10 1.01.0
© Donaldson Company, Inc.

Company, Inc.
0.8
© Donaldson Company, Inc.

0.5

© Donaldson Company, Inc.


10 3 cSt 0.5
32 cSt 0.5
10 3 3 cSt 10
10 (Diesel) 10
© Donaldson Company, Inc.

0.4

© Donaldson Company, Inc.


cSt

Company, Inc.
(Diesel) 0.5
3 cSt 0.50.5

© Donaldson
0 0.0 0
00 3 cSt (Diesel)0.0 0.0
10 20 30 40 50 60 0 0
0
10 20 30 40 50 60
0 5 10 15 20 25 30 (Diesel) 35 0 10 20 30 40 50 60

© Donaldson
0 Flow 0.0
FlowRate
Rate(GPM)
(GPM) 00 Flow Rate (GPM) 0.00.0 0
0 10 20 30 40 50 60 00 10
10 2020 Flow Rate
3030 (GPM)4040 5050 6060 0
Flow Rate (GPM) Flow
Flow Rate
Rate (GPM)
(GPM)

DBB7733 - Compact Winter Fuel Filter


DBB8664
DBB7733 Flow- Rate
- Heavy
(LPM) Oil Filter
DBB8777-- Water
WinterAbsorbing
Fuel Filter Filter
0 20 - Compact
DBB8665 Winter
Light
40 Fuel60Filter
Oil Filter DBB0248
20 Flow
Flow Rate
Rate (LPM)
(LPM) FlowFlow
RateRate
(LPM)
250 Flow Rate (LPM) (LPM)
00 5020 100
cSt 100 40
150
90150
cSt 60 200 0 50 100 150 200 0
0 50 200 1.2 0 50 100 150 200
2040 40 40
40 6000 401500
3.2 250 750 cSt 250 150
3000
cSt 90 cSt 2.5 1500
cSt
15 cSt cSt cSt cSt 2.5 cSt
2.5
1.2 2.5
2.8 3000 1500 750
1500 750 500 500
cSt cSt cSt 250
cSt cSt cSt cSt 750 250 150 cSt150
Drop (BAR)

cSt
Drop (PSI)

1530 200 0.82.0 30 cSt cSt cSt 30


2.4 30 30 2.0
cSt 2.0 2.0
Pressure Drop (BAR)

(BAR)

10
Drop (PSI)

(BAR)

Pressure Drop (BAR)


(PSI)

Pressure Drop (PSI)

Pressure Drop (PSI)


(BAR)

Pressure Drop (BAR)


2.0
Drop(PSI)

Pressure Drop (PSI)

250 0.8
Pressure

1.5
Pressure

cSt 90 cSt 1.5


90
Drop

20 1.5
Drop

10 20 cSt 1.5 20
Drop

1.6
Drop

20 32 cSt 20
150 0.4
Pressure

Pressure
Pressure

cSt
Pressure

5
Pressure

1.2 1.0
Pressure
© Donaldson Company, Inc.

1.0
1.0 1.0
10 3 cSt 32 cSt 0.4 32 cSt 32
0.8 5 3 cSt 10 10
© Donaldson Company, Inc.

(Diesel) cSt
Inc. Inc.

10

© Donaldson Company, Inc.


(Diesel) 10
© Donaldson Company, Inc.

0.5 0.5

© Donaldson Company, Inc.


Company,

0.4 0 0 0.5 0.5


3 cSt
Company,

3 cSt 3 cSt
0 5 10 15 (Diesel) 20 (Diesel)3 cSt
(Diesel)
© Donaldson

0 (Diesel)
00 Flow Rate (GPM) 00.0 0 0.0 0
© Donaldson

5 0 0 60 0.0
0
10
5
20 30
10
40
15
50
20 00 10 20 30 40 50 60 0.0
0
0 10 20 30 40 50 60 0 10 20 30 40 50 60
Flow
Flow Rate
Rate (GPM)
(GPM) Flow Rate (GPM)
Flow Rate (GPM) Flow Rate (GPM)

DBB7733 - Compact Winter Fuel Filter


DBB8777 - Winter Fuel Filter DBB8666 - Fuel Filter
DBB0248 - Water Absorbing Filter Flow Rate (LPM)
Flow Rate (LPM) 0 20 40 (LPM)
Flow Rate 60
0 50 Flow
100 Rate (LPM) 150 200 20 0 50 100 150 200
40 0 50 100 150 200 40 250
40 1500 cSt 90 cSt
750 cSt 250 1500 750 250 90 1.2
cSt
1500 cSt 2.5 cSt 60
cSt cSt cSt 2.5
2.5 cSt 2.5 cSt
cSt
150150 15
750 250
30 cSt cSt 30
cSt 2.0 2.0
30
Pressure Drop (BAR)
Pressure Drop (PSI)

2.0 2.0
320.8
(BAR)

Pressure Drop (BAR)


(PSI)

Pressure Drop (PSI)


Pressure Drop (BAR)

cSt
(BAR)
(PSI)

10
90 cSt90 1.5 1.5
Drop

Drop

1.5 20 cSt 1.5 20


Drop

Drop

20 20
cSt
Pressure

Pressure

32 cSt
Pressure

1.0 0.4 1.0


Pressure

1.0 1.0 5
© Donaldson Company, Inc.

32 cSt32
10 cSt 10
Inc.Inc.

10 3 cSt
© Donaldson Company, Inc.

0.5 3 cSt
© Donaldson Company, Inc.

(Diesel) 0.5
Company,

0.5 0.5 (Diesel) 3 cSt


Company,

3 cSt (Diesel)
0 0
3 cSt
(Diesel)
(Diesel)
© Donaldson

0 0.0 0 5 10 15 20
0 0.0
© Donaldson

0.0 0 0.0
0 10 20 30 40 50 60 0 10 20Flow Rate (GPM)
30 40 50 60
0 0 10 20 30 40 50 60
Flow Rate (GPM) Flow Rate (GPM)
Flow Rate (GPM)

DBB7733 DBB8666
- Compact Winter
- Fuel Fuel Filter
Filter
Flow Rate (LPM)
0 20 Flow Rate40(LPM) 60
0 50 100 150 200
20

2.5
30 • Clean Fuel
750 &250
40
Lubricant Solutions
1500
90
cSt
250
cSt 90 cSt
60 1.2
petroind.com
cSt cSt cSt 2.5
cSt

15
2.0 30
2.0
)
)
Flow Rate (LPM) Flow Rate (LPM)
0 20 40 60 80 100 120 0 50 100 150 200
50 40
3.2 6000
cSt 2.5
2.8 3000 1500 750 500
40

Flow Rates and Pressure Drops


cSt cSt cSt cSt
30
2.4 2.0
www.
pet
roi
nd.
com

Pressure Drop (BAR)

Pressure Drop (BAR)


Pressure Drop (PSI)

Pressure Drop (PSI)


30 2.0
32 250
cSt 1.5
cSt 20
1.6
20
1.2 1.0

0.8 10

© Donaldson Company, Inc.

© Donaldson Company, Inc.


Flow Rates and Pressure Drops
10 0.5
3
cSt 0.4

0 0 0 0.0
0 5 10 15 20 25 30 35 0 10 20 30 40 50 60

LUBRICANT FILTERS
Flow Rate (GPM)
Flow Rate (GPM)

DBB5333 - Compact
DBB8665 - Light Oil FuelFilter
Filter DBB8664
DBB0248 - Heavy
- Water Oil FilterFilter
Absorbing
P565185
Flow -Rate
Rate
Flow
8(LPM)
Micron
(LPM)
hP Flow
FlowRate
Rate(LPM)
(LPM)
P565183 - 14 Micron hP
0 0 20 50 40 60
100 80 150 100 120
200 00 50
50 100
100 150
150 200
200
Flow Rate (LPM) Flow Rate (LPM)
50 40 4040
0
3000 10 20 30 40 50 60 6000 0 10 20 30 40 50 6
3.2 1500
40 cSt 2.5 cSt
cSt 40 2.5
5000 3000
1500 750
1500 750 500 500 250 5000 3000 1500 750 2.5 500
cSt cSt
cSt cSt
cSt cSt cSt cSt cSt 2.8
2.5 3000
750 1500 250750
cSt 150
cSt 500cSt cSt cSt
40 cSt cStcSt cSt
200 cSt cSt cSt
30 3030
cSt 2.0 2.0
2.0
2.4
30 30

(BAR)
Pressure Drop (BAR)
2.0

Pressure Drop (BAR)


Pressure Drop (PSI)
Pressure Drop (PSI)

Pressure Drop (PSI)


Pressure Drop (PSI)
250

Drop(BAR)
30 2.0
Drop (PSI)

Pressure Drop (PSI)


32 cSt 250 90
1.5 cSt cSt 1.5
1.5
20 cSt 2020
150 250
Drop
1.6
1.5
cSt cSt
20 20 20
Pressure
Pressure

Pressure
1.0
1.2 1.0
1.0
32
10 1.0 cSt
100 0.8 1010
© Donaldson Company, Inc.
Inc.

Inc.
Company, Inc.
10 cSt 0.5 0.5
0.5 100
Company,

10 10

Donaldson Company,
3 cSt
Inc.

cSt 32 0.4
0.5 3 cSt
Company,

cSt (Diesel)
© Donaldson

© Donaldson
0 0 0 0.0 00 0.0
0.0 32cSt
0 0 5 10 10 20 15 30 20 4025 30
50 3560 00 10
10 20
20 30
30 40
40 50
50 60
60
© Donaldson

0.0 0
Flow Rate 8(GPM)

©
0 4 Flow Rate (GPM) 12 16 0 Rate
Flow
Flow Rate(GPM)
(GPM) 4 8 12 1

Flow Rate (GPM) Flow Rate (GPM)

DBB8777 - Winter Fuel Filter DBB8666 - Fuel Filter


P565184
DBB8665 -Rate
4 Micron
- Light
Flow hP
Oil Filter
(LPM) P565185
DBB0248 - Rate
- Water
Flow 8 Absorbing
Micron
(LPM)
2 Micron hP
hP Filter
0 50 100 150 200 0 50 100 150 200
Flow Rate (LPM) Flow Flow Rate (LPM)
40 Flow Rate (LPM) 40 Flow Rate
Rate (LPM)
(LPM)
1500 0 10 20 30 40 50 60
0 0 cSt 1050750 cSt 20 100 25030 15040 50200 60 1500
0 750 250
50
0
10090
10
150
20
200
30 40 50 6
cSt 2.5 40 cSt 60
40 40 40 cSt cSt 40 cSt cSt
2.5
3000 1500 750 500 5000
1500 3000 1500 750 5000 500
3000 1500 750
cSt cSt cSt cSt 150 cSt 2.5
2.5 cSt
cSt cSt cSt cSt cSt cStcSt cSt 2.5
2.5
cSt
30 1500 750 500 30
cSt cSt 250 250 2.0
250 150 2.0 500
cSt cSt cSt 750 cSt
200 30 cSt cSt cSt
30 30 30
(BAR)

32

(BAR)
Pressure Drop (PSI)

2.0 30 2.0
Pressure Drop (PSI)

cSt 2.0 cSt


250 2.0
(BAR)

(BAR)
Drop (PSI)

Pressure Drop (PSI)


(PSI)

90 cSt 1.5 cSt 1.5


Pressure Drop (BAR)
Drop

(BAR)
20

Drop
Pressure Drop (PSI)

(PSI)

20 250
20
Drop

Drop

DropDrop
1.5 cSt90 1.5 cSt
1.5 cSt 1.5
Pressure

20 20 20 20

Pressure
Drop

1.0 20 1.0
Pressure

150
Pressure

Pressure

Pressure
100 100
cSt
32 cSt
Pressure

cSt cSt

Pressure
10 1.0 10 1.0
1.0 100 1.0
Inc.

Inc.
0.5 32
3cSt 0.5
Company,

cSt

Company,
10 10 10 10 cSt
3 cSt 10 (Diesel)
Inc.

Inc.
© Donaldson Company, Inc.

32

Inc.
32
(Diesel) 0.5 0.5
Company,

cSt 0.5

Company,
cSt 0.5

Company,
© Donaldson

© Donaldson
0 0.0 0 0.0 32
3 cSt cSt
0 10 20 30 40 50 60 0 10 20 30 40 50 (Diesel)60
© Donaldson

Donaldson
©©Donaldson
0 0 0.0
0.0 0 0.0
Flow Rate 0 0.0
0 4 8 (GPM) 12 16 0 4 Flow
0 Rate
8 (GPM) 4 12 8 16 12 1
0 10 20 30 40 50 60 0 10 20 30 40 50 60
Flow Rate (GPM) Flow Flow Rate (GPM)
Flow Rate (GPM) Flow Rate (GPM)
Rate (GPM)

DBB7733 - Compact Winter Fuel Filter


hP Filters Rate@ 32 cSt *
P565184
0
DBB8777 - Flow
Winter Fuel
(LPM)
20
Filter 40 60
DBB8666- 4 Micron
- Fuel hP
Filter
20
0 10
P565183 - 14 Micron hP
Flow Rate (LPM)
20 Flow Rate30(LPM) 40 50 60
Flow Rate (LPM)
Flow Rate (LPM)
250 0 10 20 30 40 50 60
05 50 cSt100 150
90 cSt 200 0 50 100 150 200
40
Flow Rate (LPM) 1.2 40
40
0
1500 10
750 cSt 20
250 30 40 50 60 1500 750 500
P565183 0.30 1500 750
cSt 250 cSt cSt
90 2.5
40 cSt
15 cSt 2.5 cSt cSt cSt 60 2.5
1500 750 cSt
4 5000 3000 500 cSt
250
cSt cSt cSt cSt cSt 2.5 cSt
150 cSt P565185 0.25
(BAR)
Drop (PSI)

30
Drop(BAR)

30 30 2.0
(PSI)

0.8
2.0 2.0
(BAR)
(PSI)(PSI)

30
3
10 0.20
Pressure Drop (BAR)

2.0 32
(BAR)
Drop

Drop
Pressure Drop (PSI)

P565184
Drop (BAR)

cSt
Drop

DropDrop
(PSI)

1.5
Pressure

Pressure

90 cSt 1.5 1.5


20
Pressure

Pressure

Drop

20
250 0.15 20
Pressure

Pressure
Drop

2 32 cSt 20
100
cSt 1.5
0.4 cSt
cSt
20
Pressure

5
Pressure

1.0
Pressure

Pressure
Inc.

1.0
0.10 1.0
Company,

3 cSt
10 1 3 cSt 32 cSt 1.0 10
10
(Diesel)
Inc.
Inc.
© Donaldson Company, Inc.

(Diesel) 0.05 32
Inc.

100 0.5 0.5


Company,
Company,
© Donaldson

10 0 cSt
3 cSt 0.5
Company,

0 cSt
Inc.

3 cSt 0.5 (Diesel)


0 5 10 15 200.00
Company,

0 (Diesel)
© Donaldson
© Donaldson

0 0.0
© Donaldson

0 0 4 Flow Rate
8 (GPM) 12 32cSt 160.0 0 0 4 8 12 16 0.0
0 10 20 30 40 50 60
© Donaldson

0 0.0 0 10 20 30 40 50 60
Flow Rate (GPM) Flow Rate (GPM)
0 4 8
Flow Rate (GPM) 12 16 Flow Rate (GPM)
Flow Rate (GPM)

hP Filters @ 32 cSt*
DBB7733 - Compact Winter Fuel Filter
2 Micron hP
Flow Rate (LPM) 0 10 20
Flow Rate (LPM)
30 40 50 60
0 20 40 60 5
Flow Rate (LPM)
20
0 10 20 30 40 50 60
250 P565183
31
0.30
petroind.com
40
5000 3000
cSt
1500
90 cSt
750 1.2 4 Clean Fuel & Lubricant Solutions •
cSt cSt cSt cSt 2.5
P565185 0.25
rop (BAR)

15 500
rop (PSI)

cSt
30 3 0.20
AR)

2.0
PSI)

P565184
R)

0.8
I)
PETRO Contact Information
AFRICA CANADA
South Africa Alberta
Factory 1 - 16 Bentonite Street Bay A, 233175 Range Road 283
Alrode, Alberton, Johannesburg Rocky View, AB T1X 0J9
South Africa PO Box 75148
P: +27 (0)11 864 7758 Calgary Alberta T3H 3M1 Canada
F: +27 (0) 11 864 1649 P: +1 403 998 7190
E: sales@petroindustrial.co.za TOLL FREE: 1855 44 PETRO
F: +1 403 770 8065
AUSTRALIA E: sales@petroind.ca
Eastern Australia
Factory 2, 106 Potassium Street UAE
PO Box 407 Dubai
Narangba QLD 4504 Office LB17330, Lobby Building 17
P: 07 3204 9558 Jebel Ali Free Zone
F: 07 3293 4852 PO Box 18602
E: sales@petroindustrial.com.au Dubai, United Arab Emirates
P: +971 488 76688
Western Australia F: +971 488 76932
2 Competition Way E: salesuae@petroind.com
Wangara WA 6065
P: 08 6305 0855
F: 08 6305 0319
E: saleswa@petroindustrial.com.au

PETRO
petroind.com

Das könnte Ihnen auch gefallen