Beruflich Dokumente
Kultur Dokumente
IT T Commercial Water
Goulds Pumps
e-SV Technical Manual
e-SV Series Vertical Multi-Stage Pumps
www.goulds.com
Coverage Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General Market Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Characteristics of 1-125SV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Characteristics of 33-92SV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
General Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Applications of e-SV Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
e-SV Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
1-22SV Series Pump Cross Section and Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
33-92SV Series Pump Cross Section and Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
125SV Series Pump Cross Section and Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17
e-SV Mechanical Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Maximum Allowable Working Pressure Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Motor Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-23
3500 RPM Curves, Dimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-45
1750 RPM Curves, Dimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-67
Horizontal Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68-71
Table of Hydraulic Performances at 3500 RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72-77
Table of Hydraulic Performances at 1750 RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78-83
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Technical Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84-87
GOULDS PUMPS 2
Commercial Water
e-SV Coverage Curve
METERS FEET
1200
350 3500 RPM
300 1000
250 800
200 22SV
600
150
125SV
400
100
200
50 46 66 92
1SV 3SV 5SV 10SV 15SV 33SV SV SV SV
0
1 2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 GPM
METERS FEET
300
1750 RPM
75 250
200
50
150
22SV
125SV
100
66 92
25 SV SV
50 33 46
1SV 3SV 5SV 10SV 15SV SV SV
0 0
1 2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 GPM
GOULDS PUMPS 3
Commercial Water
e-SV General Market Specifications
Applications
• Handling of water, free of suspended solids, in the municipal,
industrial and agricultural markets
• Pressure boosting and water supply systems
• Fire fighting jockey pumps
• Irrigation systems
• Wash systems
• Water treatment plants: reverse osmosis
• Handling of moderately aggressive liquids, demineralized water,
water and glycol, etc.
• Circulation of hot and cold water for heating, cooling and
conditioning systems
• Boiler feed
Specifications
PUMP
The e-SV pump is a non-self priming vertical multistage pump coupled to
a standard motor.
The liquid end, located between the upper cover and the pump casing, is
held in place by tie rods. The pump casing is available with different
configurations and connection types.
• Delivery: up to 725 GPM
• Head: up to 1200 feet
• Temperature of pumped liquid:
-20ºF to 250ºF (-30ºC to 120ºC) standard version
• Optional temperature range up to 300ºF (149ºC) high temperature version
• Maximum operating pressure
– SV1-22 with oval flanges: 230 PSI (16 bar)
– SV1-22 with round flanges or Victaulic: 360 or 575 PSI (25 or 40 bar)
– SV33, 46: 360 or 580 PSI (25 or 40 bar)*
– SV 66, 92: 360 or 580 PSI (25 or 40 bar)*
– SV 125: 360 or 580 PSI (25 or 40 bar)
• Direction of rotation: clockwise looking at the pump from the top down
(marked with an arrow on the adapter and on the coupling).
MOTOR
• Standard NEMA TC Frame motors in open drip proof or
totally enclosed fan cooled.
• 3500 RPM nominal
• Standard voltage:
• Single phase version: 115-208/230 V, 60 Hz up to 3 HP or
208-230 V for 5 HP
• Three phase version, 2 pole: 208-230/460 V, 60 Hz up 75 HP
* Based on pump staging
GOULDS PUMPS 4
Commercial Water
e-SV Characteristics
Optional Features
• Horizontal version. • Premium E and explosion proof motors.
• Special voltages, 50 Hz frequency. • 1750 RPM, 4 pole motors.
• Special materials for the mechanical seal, gaskets and elastomers, • Passivation or electro polishing
• Tropicalized motors.
GOULDS PUMPS 5
Commercial Water
General Characteristics
2-pole
SERIES SVT SERIES SVF, SVN SERIES SVR SERIES SVP SERIES SVG, SVN
1SV, 3SV, 5SV, 1SV, 3SV, 5SV, 1SV, 3SV, 5SV, VICTAULIC 33SV, 46SV, 66SV,
10SV, 15SV, 22SV 10SV, 15SV, 22SV 10SV, 15SV, 22SV 1SV, 3SV, 5SV, 92SV, 125SV
10SV, 15SV, 22SV
e-SV Product Range 1SV 3SV 5SV 10SV 15SV 22SV 33SV 46SV 66SV 92SV 125SV
Nominal Flow (GPM) 9 15 30 50 80 110 150 220 350 450 600
Flow Range(GPM) 2-12 3-22 7-45 9-75 18-125 21-150 30-195 45-285 70-420 90-580 120-700
Max. Head (Ft) 860 1085 975 1150 1060 880 1125 1210 850 715 570
Max. Working Pressure (PSIG) 580 360/580
Temperature Range (°F) Standard -20°F - 250°F (-30°C - 121°C)
High Temp Option up to 300°F (150°C) –
Motor Power [HP] ½ – 5 HP ½ – 7½ ¾ – 10 ¾ – 20 2 – 25 3 – 30 3 – 60 7½ – 75 10 – 75 15 – 75 20 – 75
Max Pump Efficiency 51% 60% 70% 70% 70% 71% 76% 78% 78% 80% 79%
Materials of Construction
SVT 304 SS –
SVF 304 SS –
SVN 316L SS Cast Stainless Steel / 316L SS
SVR 304 SS –
SVP 316L SS –
SVC 316L SS –
SVG ASTM Class 35/40B Cast Iron / 304 SS
Connection Sizes
SVT - Oval NPT 1¼" 1¼" 1¼" 1½" 1½" 1½" –
SVF - Round ANSI 1¼" 1¼" 1¼" 2" 2" 2"
–
Size/Class 300# 300# 300# 300# 300# 300#
SVN - Round ANSI 1¼" 1¼" 1¼" 2" 2" 2" 2½" 3" 4" 4" 5"
Size/Class 300# 300# 300# 300# 300# 300# 150/300# 150/300# 150/300# 150/300# 150/300#
SVR - Top/Bottom Round 1¼" 1¼" 1¼" 2" 2" 2"
–
ANSI Size/Class 300# 300# 300# 300# 300# 300#
SVP - Victaulic 1¼" 1¼" 1¼" 2" 2" 2" –
SVC - Clamp 1¼" 1¼" 1¼" 2" 2" 2" –
SVG - Cast Iron 1¼" 1¼" 1¼" 2" 2" 2" 2½" 3" 4" 4" 5"
Size/Class 250# 250# 250# 250# 250# 250# 125/250# 125/250# 125/ 250# 125/ 250# 125/200#
GOULDS PUMPS 6
Commercial Water
Typical Applications of e-SV Series Multi-Stage Pumps
Water Treatment
• Ultra filtration systems
• Reverse osmosis systems
• Water softeners and de-mineralization
• Distillation systems
• Filtration
Light Industry
• Washing and cleaning plants (washing and degreasing of mechanical
parts, car and truck wash tunnels, washing of electronic industry circuits)
• Commercial washers
• Fire fighting system pumps
GOULDS PUMPS 7
Commercial Water
e-SV Product Line
Numbering System for 1 – 22SV Liquid End Only
The various versions of the e-SV line are identified by a product code number on the pump label. This number is also
the catalog number for the pump. The meaning of each digit in the product code number is shown below.
Note: Not all combinations are possible.
Example Product Code
22 SV 0 2 F E 3 0
GOULDS PUMPS 8
Commercial Water
e-SV Product Line
Numbering System for 33 – 125SV Liquid End Only
The various versions of the e-SV line are identified by a product code number on the pump label. This number is also
the catalog number for the pump. The meaning of each digit in the product code number is shown below.
Note: Not all combinations are possible.
Example Product Code
125 SV 8 1 2 B F E 2 0
GOULDS PUMPS 9
Commercial Water
e-SV Product Line
Numbering System for 1 – 22SV Pump & Motor Combination
The various versions of the e-SV line are identified by a product code number on the pump label. This number is also
the catalog number for the pump. The meaning of each digit in the product code number is shown below.
Note: Not all combinations are possible.
Example Product Code
2 SV 2 2 F A 2 F 5 1 A H
GOULDS PUMPS 10
Commercial Water
e-SV Product Line
Numbering System for 33 – 125SV Pump & Motor Combination
The various versions of the e-SV line are identified by a product code number on the pump label. This number is also
the catalog number for the pump. The meaning of each digit in the product code number is shown below.
Note: Not all combinations are possible.
Example Product Code
125 SV 8 2 A G K 3 F 2 0
GOULDS PUMPS 11
Commercial Water
Base Models: 1-22SV
Major Components
GOULDS PUMPS 12
Commercial Water
Base Models: 1-22SV
Major Components
F, P, R VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
1 Pump Body Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
2 Impeller Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
3 Diffuser Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
4 Casing Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
5 Shaft Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
6 Adapter Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
7 Base Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8 Coupling Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
9 Seal Plate Stainless Steel AISI 316L EN 10088-1-X2-CrNi17-12-2 (1.4404)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Fill/Drain Plugs Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
15 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
16 Wear Ring PPS
17 Seal Gland Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
N, P, C VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
1 Pump Body Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
2 Impeller Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
3 Diffuser Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
4 Casing Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
5 Shaft Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
6 Adapter Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
7 Base Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8 Coupling Aluminum A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
9 Seal Plate Stainless Steel AISI 316L EN 10088-1-X2-CrNi17-12-2 (1.4404)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Fill/Drain Plugs Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
15 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
16 Wear Ring PPS
17 Seal Gland Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
GOULDS PUMPS 13
Commercial Water
Base Model: 33SV, 46SV, 66SV, 92SV and 125SV
Major Components
SV G-N
45 36
6
8
11
44
13
29 9 18
41
3 3 18
49 15
16
46
19 48
12 LESS PISTON 34
5 10
4
38 2
30 30
24
20
21
47 28
31 23
35
26
18
37 18
39 27 14
27A
25 32 40
22 1 10
12
WITH PISTON
33
35 28
7 40
23
42
1
12 10
GOULDS PUMPS 14
Commercial Water
Base Model: 33SV, 46SV, 66SV, 92SV and 125SV
Major Components
GOULDS PUMPS 15
Commercial Water
Base Models: 125SV
Major Components
SV G-N
GOULDS PUMPS 16
Commercial Water
Base Models: 125SV
Major Components
G VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
1 Pump Body Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
2 Impeller Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
3 Diffuser Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
4 Casing Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
5 Shaft Duplex Stainless Steel UNS S 31803 EN 10088-1-X17-CrNiMoN22-5-3 (1.4507)
Adapter (up to 40HP) Cast Iron ASTM Class 25 EN 1561-GJL-200 (JL1040)
6
Adapter (50HP and higher) ASTM Class A536 EN 1561-GJL-500-7 (JS1050)
7 Wear Ring PPS
Coupling (up to 40HP) Cast Iron A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8
Coupling (50HP and higher)
9-9A Upper Head / Seal Housing Cast Iron ASTM Class 35/40B EN 1561-GJL-250 (JL1040)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Bushing for Diffuser Carbon
15 Fill/Drain Plugs Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
16 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
17 Adapter Ring Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
N VERSIONS
Reference Standards
Ref. No. Name Material
USA Europe
1 Pump Body Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
2 Impeller Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
3 Diffuser Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
4 Casing Stainless Steel AISI 316L EN 10088-1-X2-CrNiMo17-12-2 (1.4404)
5 Shaft Duplex Stainless Steel UNS S 31803 EN 10088-1-X17-CrNiMoN22-5-3 (1.4507)
Adapter (up to 40HP) Cast Iron ASTM Class 25 EN 1561-GJL-200 (JL1040)
6
Adapter (50HP and higher) ASTM Class A536 EN 1561-GJL-500-7 (JS1050)
7 Wear Ring PPS
Coupling (up to 40HP) Cast Iron A384.0-F EN 1706-AC-AlSi11Cu2(Fe) (AC46100)
8
Coupling (50HP and higher)
9-9A Upper Head / Seal Housing Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
10 Mechanical Seal Silicon Carbide / Carbon / Viton (opt. EPDM)
11 Elastomers Viton (opt. EPDM)
12 Coupling Guard Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
13 Shaft Sleeve and Bushing Tungsten Carbide
14 Bushing for Diffuser Carbon
15 Fill/Drain Plugs Stainless Steel AISI 316 EN 10088-1-X2-CrNiMo17-12-2 (1.4401)
16 Tie Rods Carbon Steel / Zinc Plated A29 Gr. 1045 EN 10277
17 Adapter Ring Stainless Steel AISI 304 EN 10088-1-X5-CrNi18-10 (1.4301)
GOULDS PUMPS 17
Commercial Water
e-SV Mechanical Seals
1 – 22SV 33 – 125SV
Rotating Face Stationary Face Elastomers Spring Metal Components Elastomer Temp Seal Temp Max. Working
Pump Code Application
1 2 3 4 5 Limits °F (°C) Limits °F (°C) Pressure
1SV 0 Carbon Viton General Service
-14 - 392°F
3SV 2 Silicon Carbide -22 - 250°F 580 psi
(-10 - 200°C) Abrasive
5SV 4 Graphite Filled Silicon Carbide
(-30 - 120°C) (40 bar)
EPR 316SS 316SS -30 - 300°F
10V 6 Carbon Graphite Filled (-34 - 150°C)
General Service
15SV -14 - 392°F
FDA Grade up to 340°F 255 psi
1 AFLAS (-10 - 200°C) Boiler Feed
22SV Carbon (171°C) (17.6 bar)
33SV 0 Carbon General Service
46SV 2 Viton -14 - 392°F
Silicon Carbide Silicon Carbide (-10 - 200°C) -22 - 250°F 580 psi
66SV 316SS 316SS Abrasive
4 Graphite Filled Graphite Filled (-30 - 120°C) (40 bar)
92SV -22 -
250°F
EPR
125SV 6 Carbon (-30 - 120°C)
General Service
Rotating Stationary
Elastomers Spring Sleeve Set Screw Locking
Pump Face Face Collar
1 2 3 4 5 6
33SV VENT 1⁄8 NPT
Carbon Viton
46SV
Silicon
316SS 316SS 300SS 316SS
66SV Carbide
Silicon
Carbide EPR VENT 1⁄8 NPT
92SV
7 5 4 3 2 1 3 3 PULLER
HOLES
6
CARTRIDGE SEAL
GOULDS PUMPS 18
Commercial Water
Maximum Allowable Working Pressure Charts
GOULDS PUMPS 19
Commercial Water
Motor Data – Starts per Hour / Minimum Run Time
HP Max Starts per Hour* Min. run time between starts (seconds)
0.5 24 120
0.75 24 120
1 15 75
1.5 13 76
2 12 77
3 9 30
5 8 83
7.5 7 88
10 6 92
15 5 100
20 5 110
25 5 115
30 4 120
40 4 130
50 3 145
60 3 170
75 3 180
NOTE(S)
1) Recommended motor starts per hour and minimum run time calculated based on NEMA standards MG1-12.44 in accordance to
manufacturers allowable tolerance for heat rise and insulation breakdown.
2) Applied voltage and frequency in accordance with NEMA MG1-12.44
3) Starts based on NEMA three phase design A and design B AC induction motors.
4) External load WK2 is equal to or less than the values listed in NEMA MG1-12.54
5) Applicable to all NEMA (JM, JP, T and TC frame) motors used for Goulds Pumps products.
6) Applicable to three phase motors only.
GOULDS PUMPS 20
Commercial Water
Motor Data
GOULDS PUMPS 21
Commercial Water
Motor Data
GOULDS PUMPS 22
Commercial Water
Motor Data
GOULDS PUMPS 23
Commercial Water
Dimensions and Weights
1SV Series 3500 RPM
GOULDS PUMPS 24
Commercial Water
1SV Curve 3500 RPM
Q [m3/hr]
28
27
26
25
24
22
20
19
17
15
13
12
11
10
9
8
7
6
5
4
3
2
GOULDS PUMPS 25
Commercial Water
Dimensions and Weights
3SV Series 3500 RPM
GOULDS PUMPS 26
Commercial Water
3SV Curve 3500 RPM
Q [m3/hr]
27
26
24
22
20
18
16
14
13
12
11
10
9
8
7
6
5
4
3
2
GOULDS PUMPS 27
Commercial Water
Dimensions and Weights
5SV Series 3500 RPM
GOULDS PUMPS 28
Commercial Water
5SV Curve 3500 RPM
Q [m3/hr]
23
21
20
17
15
14
13
12
11
10
9
8
7
6
5
4
3
2
GOULDS PUMPS 29
Commercial Water
Dimensions and Weights
10SV Series 3500 RPM
GOULDS PUMPS 30
Commercial Water
10SV Curve 3500 RPM
13
12
11
10
9
8
7
6
2
1
GOULDS PUMPS 31
Commercial Water
Dimensions and Weights
15SV Series 3500 RPM
GOULDS PUMPS 32
Commercial Water
15SV Curve 3500 RPM
Q [m3/hr]
14
13
12
11
10
GOULDS PUMPS 33
Commercial Water
Dimensions and Weights
22SV Series 3500 RPM
GOULDS PUMPS 34
Commercial Water
22SV Curve 3500 RPM
Q [m3/hr]
11
14
10
GOULDS PUMPS 35
Commercial Water
Dimensions and Weights
33SV Series 3500 RPM
8.66 L2
(220) 4.11
6.69 7.50 (104.5)
(170) (190.5)
7.50 (190.5)
Cast Iron 316SS
2½" Class 125 R.F. 2½" Class 150 R.F.
9.45 11.42 (1 – 4 Stages)
(240) (290) (1 – 4 Stages)
VENT FILL
1/2 BSP Ø 5.88 B.C.
1/2 BSP Ø 5.88 B.C. (149.3)
Ø .6 (15) (149.3) Ø .88 (22)
4 HOLES L1 Ø .88 (22) 8 HOLES
8 HOLES
3/8 3/8
NPT NPT
4.13
(105) 4.94 4.11
DRAIN 1/2 BSP (125.5) (104.5)
1.18 12.60 7.50 (190.5) 7.50 (190.5)
(30) (320) Cast Iron 316SS
2½" Class 250 R.F. 2½" Class 300 R.F.
All dimensions are in inches (mm). (5 – 10 Stages) (5 – 10 Stages)
GOULDS PUMPS 36
Commercial Water
33SV Curve 3500 RPM
0 10 20 30 40 50 Q [m3/h]
9
1000 9/1
300
9/2
900 8
8/1
8/2
250
800 7
7/2
700 6
6/1 200
6/2
600
5
5/1
5/2
500 150
4
4/1
400 4/2
3
3/1 100
300 3/2
2
200 2/1
2/2
50
1
100 1/1
0 0
6 80
Full Dia.
HP/STAGE
4 70
EFF [%]
2 60
Efficiency [%]
Reduced Dia.
0 50
40
10
NPSHr [METERS]
NPSHr [FEET]
30
8
20 6
4
10
2
0 0
0 25 50 75 100 125 150 175 200 225 250
Q [US GPM]
MINIMUM FLOW RATE: 35 GPM [8 m3/hr]
GOULDS PUMPS 37
Commercial Water
Dimensions and Weights
46SV Series 3500 RPM
L2
9.45 8.25 5.00 (127)
(240) (209.5)
7.48 8.25 (209.5)
(190) Cast Iron 316SS
3" Class 125 R.F. 3" Class 150 R.F.
(1 – 3 Stages) (1 – 3 Stages)
10.43 12.40
(265) (315) VENT FILL
1/2 BSP 1/2 BSP
Ø 6.62 B.C. Ø 6.62 B.C.
(168.2) (168.2) Ø .88 (22)
Ø .6 (15) L1 Ø .88 (22) 8 HOLES
4 HOLES 3/8 3/8 8 HOLES
NPT NPT
5.5
(140)
DRAIN 1/2 BSP
1.77 5.69
(45) 14.4 5.00 (127)
(365) (144.5)
8.25 (209.5) 8.25 (209.5)
All dimensions are in inches (mm). Cast Iron 316SS
3" Class 250 R.F. 3" Class 300 R.F.
(4 – 10 Stages) (4 – 10 Stages)
GOULDS PUMPS 38
Commercial Water
46SV Curve 3500 RPM
0 10 20 30 40 50 60 70 Q [m3/h]
9 350
9/1
1100 9/2
8
1000 8/1
300
8/2
900 7
7/1
TOTAL DYNAMIC HEAD [FEET]
5 200
5/1
600
5/2
4
500 4/1 150
4/2
400 3
3/1
3/2 100
300
2
2/1
200 2/2
50
1
100 1/1
0 0
80
8 Full Dia.
Efficiency [%]
HP/STAGE
7 70
EFF [%]
6 Reduced Dia.
60
5
4 50
20 6
NPSHr [METERS]
NPSHr [FEET]
16 5
12 4
3
8
2
4
0 50 100 150 200 250 300 350
Q [US GPM]
MINIMUM FLOW RATE: 40 GPM [9 m3/hr]
GOULDS PUMPS 39
Commercial Water
Dimensions and Weights
66SV Series 3500 RPM
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19)
(265) (315) Ø 0.75 (19)
8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
GOULDS PUMPS 40
Commercial Water
66SV Curve 3500 RPM
0 20 40 60 80 100 Q [m3/h]
66SV 60 Hz
6 3500 RPM
TOTAL STAGES/REDUCED STAGES
6/1 250
800 6/2
5
700
5/1
5/2 200
4/1
4/2
500 150
400 3/1
3/2
100
300 2
2/1
2/2
200
50
1
1/1
100
0 0
14 80
Full Dia.
12
HP/STAGE
70
EFF %
10 Reduced Dia.
60
8
Efficiency [%]
6 50
12
40
NPSHr [METERS]
10
NPSHr [FEET]
30 8
20 6
4
10
2
0 0
0 50 100 150 200 250 300 350 400 450 500
Q [US GPM]
GOULDS PUMPS 41
Commercial Water
Dimensions and Weights
92SV Series 3500 RPM
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19)
(265) (315) Ø 0.75 (19)
8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
GOULDS PUMPS 42
Commercial Water
92SV Curve 3500 RPM
4
600 180
4/1
4/2
500
3 140
3/1
3/2
400 120
100
2
300
2/1
2/2 80
200 60
1
1/1 40
100
20
0 0
20 85
18 Full Dia. 80
16 75
HP/STAGE
EFF %
14 Reduced Dia. 70
12 65
10 60
8 Efficiency [%] 55
6 50
50
14
NPSHr [METERS]
40
NPSHr [FEET]
12
30 10
8
20 6
10 4
2
0 0
0 100 200 300 400 500 600 700
Q [US GPM]
GOULDS PUMPS 43
Commercial Water
Dimensions and Weights
125SV Series 3500 RPM
GOULDS PUMPS 44
Commercial Water
125SV Curve 3500 RPM
125SV 60Hz
3500 RPM
5/0C
5/5B
4/3B
3/3A
2/0C
1/0C
GOULDS PUMPS 45
Commercial Water
Dimensions and Weights
1SV Series 1750 RPM
GOULDS PUMPS 46
Commercial Water
1SV Curve 1750 RPM
Q [m3/hr]
28
27
26
25
24
22
20
19
17
15
13
12
11
10
9
8
7
6
5
4
3
2
GOULDS PUMPS 47
Commercial Water
Dimensions and Weights
3SV Series 1750 RPM
GOULDS PUMPS 48
Commercial Water
3SV Curve 1750 RPM
Q [m3/hr]
3SV 60Hz
1750 RPM
TOTAL STAGES
30
29
27
26
24
22
20
18
16
14
13
12
11
10
9
8
7
6
5
4
3
2
GOULDS PUMPS 49
Commercial Water
Dimensions and Weights
5SV Series 1750 RPM
GOULDS PUMPS 50
Commercial Water
5SV Curve 1750 RPM
Q [m3/hr]
23
21
20
18
17
15
14
13
12
11
10
9
8
7
6
5
4
3
2
GOULDS PUMPS 51
Commercial Water
Dimensions and Weights
10SV Series 1750 RPM
GOULDS PUMPS 52
Commercial Water
10SV Curve 1750 RPM
Q [m3/hr]
13
12
11
10
9
8
7
6
5
4
3
2
1
GOULDS PUMPS 53
Commercial Water
Dimensions and Weights
15SV Series 1750 RPM
GOULDS PUMPS 54
Commercial Water
15SV Curve 1750 RPM
Q [m3/hr]
15SV 60Hz
1750 RPM
TOTAL STAGES
15
14
13
12
11
10
GOULDS PUMPS 55
Commercial Water
Dimensions and Weights
22SV Series 1750 RPM
GOULDS PUMPS 56
Commercial Water
22SV Curve 1750 RPM
Q [m3/hr]
22SV 60Hz
1750 RPM
TOTAL STAGES
12
11
10
GOULDS PUMPS 57
Commercial Water
Dimensions and Weights
33SV Series 1750 RPM
8.66 L2
(220) 4.11
6.69 7.50 (104.5)
(170) (190.5)
7.50 (190.5)
Cast Iron 316SS
9.45 11.42 2½" Class 125 R.F. 2½" Class 150 R.F.
(240) (290) (1 – 4 Stages) (1 – 4 Stages)
VENT FILL
1/2 BSP Ø 5.88 B.C.
1/2 BSP Ø 5.88 B.C. (149.3)
Ø .6 (15) (149.3) Ø .87 (22)
4 HOLES L1 Ø .87 (22) 8 HOLES
8 HOLES
3/8 3/8
NPT NPT
4.13
(105) 4.94 4.11
DRAIN 1/2 BSP (125.5) (104.5)
1.18 12.60 7.50 (190.5) 7.50 (190.5)
(30) (320) Cast Iron 316SS
2½" Class 250 R.F. 2½" Class 300 R.F.
All dimensions are in inches (mm).
(5 – 10 Stages) (5 – 10 Stages)
GOULDS PUMPS 58
Commercial Water
33SV Curve 1750 RPM
0 5 10 15 20 25 Q [m3/h]
300
33SV 60 Hz 90
TOTAL STAGES/REDUCED STAGES 1750 RPM
10
10/1
10/2 80
9
9/1
9/2
70
8
8/1
8/2
200
7 60
7/2
6
50
6/1
6/2
5
5/1 40
5/2
4
4/1
100 4/2 30
20
2
1 10
0 0
1 80
.75
HP/STAGE
Full Dia. 70
EFF %
.5
60
.25
Efficiency [%]
Reduced Dia.
0 50
10 3
NPSHr [METERS]
8
NPSHr [FEET]
2
6
4
1
2
0 0
0 25 50 75 100 125
Q [US GPM]
MINIMUM FLOW RATE: 18 GPM [4 m3/hr]
GOULDS PUMPS 59
Commercial Water
Dimensions and Weights
46SV Series 1750 RPM
L2
9.45 8.25 5.00 (127)
(240) (209.5)
7.48 8.25 (209.5)
(190) Cast Iron 316SS
3" Class 125 R.F. 3" Class 150 R.F.
(1 – 3 Stages) (1 – 3 Stages)
10.43 12.40
(265) (315) VENT FILL
1/2 BSP 1/2 BSP
Ø 6.62 B.C. Ø 6.62 B.C.
(168.2) (168.2) Ø .87 (22)
Ø .6 (15) L1 Ø .87 (22) 8 HOLES
4 HOLES 3/8 3/8 8 HOLES
NPT NPT
GOULDS PUMPS 60
Commercial Water
46SV Curve 1750 RPM
0 5 10 15 20 25 30 35 Q [m3/h]
350
46SV 60 Hz
1750 RPM 100
TOTAL STAGES/REDUCED STAGES
10
10/1
300 10/2 90
9
9/1
9/2
80
8
250 8/1
8/2
70
7
7/1
7/2
200 60
6
6/1
6/2
5 50
150 5/1
5/2
4 40
4/1
4/2
100 3 30
3/1
3/2
2 20
50
1 10
0 0
1.5 80
70
HP/STAGE
1 Full Dia.
EFF %
60
.5 Efficiency [%] Reduced Dia.
50
0 40
5
NPSHr [METERS]
NPSHr [FEET]
4 3
3
2
2
1
1
0 20 40 60 80 100 120 140 160 180
Q [US GPM]
MINIMUM FLOW RATE: 20 GPM [5 m3/hr]
GOULDS PUMPS 61
Commercial Water
Dimensions and Weights
66SV Series 1750 RPM
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19)
(265) (315) Ø .87 (22)
8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
GOULDS PUMPS 62
Commercial Water
66SV Curve 1750 RPM
0 10 20 30 40 50 Q [m3/h]
250
66SV 60 Hz
TOTAL STAGES/REDUCED STAGES 1750 RPM
70
6
200 6/1
60
6/2
5
5/1
50
5/2
150
4
4/1 40
4/2
3
100 3/1 30
3/2
2
2/1 20
2/2
50
1
10
0 0
3 80
HP/STAGE
2 70
Full Dia.
EFF %
1 60
Reduced Dia.
Efficiency [%]
0 50
12
NPSHr [METERS]
10 3
NPSHr [FEET]
8
6 2
4
1
2
0 0
0 50 100 150 200 250
Q [US GPM]
MINIMUM FLOW RATE: 35 GPM [8 m3/hr]
GOULDS PUMPS 63
Commercial Water
Dimensions and Weights
92SV Series 1750 RPM
9.45
(240)
7.48
(190)
Ø 7.50 B.C. Ø 7.50 B.C.
(190.5) (190.5)
10.43 12.40 Ø .75 (19)
(265) (315) Ø .87 (22)
8 HOLES 8 HOLES
Ø .6 (15)
4 HOLES
M
REF
D1
L1
3/8 3/8
NPT NPT
GOULDS PUMPS 64
Commercial Water
92SV Curve 1750 RPM
0 10 20 30 40 50 60 70 80 Q [m3/h]
250
92SV 60 Hz
TOTAL STAGES/REDUCED STAGES 1750 RPM
6 70
6/1
6/2
200
60
5
5/1
5/2
50
4
150 4/1
4/2
40
3
3/1
3/2
100 30
2
2/1
2/2 20
50
1
1/1 10
0 0
3 80
Full Dia.
HP/STAGE
2 70
EFF %
Reduced Dia.
1 60
Efficiency [%]
0 50
20 6
NPSHr [METERS]
5
NPSHr [FEET]
4
10 3
2
1
0 0
0 100 200 300 400
Q [US GPM]
MINIMUM FLOW RATE: 50 GPM [11 m3/hr]
GOULDS PUMPS 65
Commercial Water
Dimensions and Weights
125SV Series 1750 RPM
GOULDS PUMPS 66
Commercial Water
125SV Curve 1750 RPM
125SV 60Hz
1750 RPM
8/0C
7/0C
6/6A
5/5A
4/0C
3/3A
2/0C
GOULDS PUMPS 67
Commercial Water
1SV – 22SV Horizontal Mounting Option
• Consists of e-SV pump with base mounting foot and footed motor for horizontal installations.
• Unit depicted may not show actual pump configuration. Use for mounting location only.
GOULDS PUMPS 68
Commercial Water
1SV – 22SV Horizontal Mounting Option
GOULDS PUMPS 69
Commercial Water
33SV – 92SV Horizontal Mounting Option
• Consists of e-SV pump with base mounting foot and footed motor for horizontal installations.
• Unit depicted may not show actual pump configuration. Use for mounting location only.
GOULDS PUMPS 70
Commercial Water
125SV Horizontal Mounting Option
• Consists of e-SV pump with base mounting foot and footed motor for horizontal installations.
• Unit depicted may not show actual pump configuration. Use for mounting location only.
GOULDS PUMPS 71
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 72
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 73
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 74
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 75
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 76
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 77
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 78
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 79
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 80
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 81
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
GOULDS PUMPS 82
Commercial Water
Technical Data – Pump Hydraulics / Motor Sizing
Maximum Inlet Pressure Pump Stages P1max (psig) Pump Stages P1max (psig)
The following table shows the maximum permissible inlet pres- 2-5 145 1/1-2/2 45
1SV 6-10 218 2/1-5/2 145
sure. However, the actual inlet pressure + pressure against a 11-30 PN-Pmax 33SV
5/1-7/2 218
closed valve must always be lower than the maximum permissible 2-3 145 7/1-10 PN-Pmax
operating pressure. 3SV 4-7 218 1/1-1 145
8-30 PN-Pmax 2/2-2 218
46SV
2-3 145 3/2-4/1 290
p1max ≤ PN - pmax 4-10/2 PN-Pmax
5SV 4-6 290
Having the following 7-27 PN-Pmax 1/1-3/2 72
meaning of the symbols: 1-2 145
66SV
3/1-4/1 145
10SV 3-5 290 4-5/1 218
pmax = Maximum pressure 6-20 PN-Pmax 5-6 PN-Pmax
delivered by the 1-2 145 1/1-2/2 72
pump 15SV 3 290 2/1-3/2 145
92SV
4-15 PN-Pmax 3/1-3 218
p1max = Maximum inlet 4/2-5/1 PN-Pmax
pressure 1-2 145
22SV 3 290 1-2 290
125SV
PN = Maximum operating 4-12 PN-Pmax 3-8 PN-Pmax
pressure
GOULDS PUMPS 83
Commercial Water
Technical Data – Water Property Chart
GOULDS PUMPS 84
Commercial Water
Technical Data – NPSH
NPSH
The minimum operating values that can be reached at the pump The maximum possible suction head for installation depends on
suction end are limited by the onset of cavitation. the value of the atmospheric pressure (i.e. the elevation above
sea level at which the pump is installed) and the temperature of
Cavitation is the formation of vapor-filled cavities within liquids
the liquid.
where the pressure is locally reduced to a critical value, or where
the local pressure is equal to, or just below the vapor pressure of To help the user, with reference to water temperature (40ºF) and
the liquid. to the elevation above sea level, the following tables show the
drop in hydraulic pressure head in relation to the elevation above
The vapor-filled cavities flow with the current and when they
sea level, and the suction loss in relation to temperature.
reach a higher pressure ares the vapor contained in the cavities
condenses. The cavities collide, generating pressure waves that Water Temperature (ºF) 68 104 140 176 194 230 248
are transmitted to the walls. These, being subjected to stress Suction Loss (ft) -.7 2.3 6.6 16.4 24.3 50.5 70.5
cycles, gradually become deformed and yield due to fatigue. This
phenomenon, characterized by a metallic noise produced by the Elevation Above Sea Level (ft) 1600 3300 4900 6500 8200 9800
hammering on the pipe walls, is called incipient cavitation. Suction Loss (ft) 1.8 3.6 5.4 7.2 9.0 10.8
The damage caused by cavitation may be magnified by electro- To reduce it to a minimum, especially in cases of high suction
chemical corrosion and a local rise in temperature due to the plas- head (over 13 – 16 feet) or within the operating limits with high
tic deformation of the walls. The materials that offer the highest flow rates, we recommend using a suction line having a larger
resistance to heat and corrosion are alloy steels, especially austen- diameter than that of the pump’s suction port. It is always a good
itic steel. The conditions that trigger cavitation may be assessed idea to position the pump as close as possible to the liquid to be
by calculating the total net suction head, referred to in technical pumped.
literature with the acronym NPSH (Net Positive Suction Head).
The NPSH represents the total energy (expressed in feet) of the
liquid measured at suction under conditions of incipient cavita-
tion, excluding the vapor pressure (expressed in feet) that the
liquid has at the pump inlet.
To find the static height (hz) at which to install the machine under
safe conditions, the following formula must be verified:
hp + hz ≥ (NPSHr + 2 ft) + hf + hpv
where:
hp is the absolute pressure applied to the free liquid surface in
the suction tank, expressed in feet of liquid; hp is the
quotient between the barometric pressure and the specific
weight of the liquid.
hz is the suction lift between the pump axis and the free liquid
surface in the suction tank, expressed in feet; hz is negative
when the liquid level is lower than the pump axis.
hf is the flow resistance in the suction line and its accessories,
such as: fittings, foot valve, gate valve, elbows, etc.
hpv is the vapor pressure of the liquid at the operating
temperature, expressed in feet of the liquid. hpv is the
quotient between the Pv vapor pressure and the liquid‘s
specific weight.
0.5 is the safety factor.
GOULDS PUMPS 85
Commercial Water
Technical Data – Compatability Chart for Materials
in Contact with Most Commonly Used Liquids
GOULDS PUMPS 86
Commercial Water
Notes
GOULDS PUMPS 87
Commercial Water
IT T Commercial Water
Engineered for life 1 Goulds Drive, Auburn, NY 13021 Printed on recycled paper.