Sie sind auf Seite 1von 45

ENERGY EFFICIENT HOTELS

PRESENTED BY:
Ataulla Khan Kumar Avinash Nitin Sharma Pranav Arora Sudhanshu Srivastava
About hotels
- Hotel industry is a large business sector.
- Can play a major role changing the culture of environmental degradation practices to achieve
sustainable growth.

Consumes a big proportion of electricity as compared to other tourism sectors.


 The use of water in a hotel is extensive and it is used in many different ways, such as cold
water for kitchen, laundry, drinking, circulation for air taming hot water for guest bathrooms
and flow for space heating.
Water consumption at this rate that to without monitoring, will likely guide to water
shortages.
Another factor that affects water is not only consumption but also contamination.
PRESENTED BY: Nitin Sharma
Why become a Green Star Hotel?

There are several good reasons

 Join Green Star Hotel and your hotel will be featured


as part of a strong marketing and promotion
activities carried out by the national and
international project partners.
 Through the support of international tourism
organisations and projects the programme and its
certified hotels are also presented prominently in
conferences, trade shows, and international
workshops and on several web portals.
 Market your hotel and its environmental activities
by using the Green Star Hotel brand and marketing
tools.

PRESENTED BY: Nitin Sharma


Protecting the attractions that bring more visitors
to your destination helps ensure the long term
sustainability of your business!!

Saving money

By implementing the Green Star Hotel criteria


system, which also includes complex staff training
measures, your hotel can reduce operating costs
(e.g. reduction of water and energy consumption)
and increase operational efficiency.

Gain a competitive market advantage … promote to a wide audience

You can be confident that you will become more attractive to the growing number of
environmentally friendly tourists. Also the level of satisfaction among your customers will
increase who can actively contribute to the protection of environment without reducing
their level of comfort.

PRESENTED BY: Nitin Sharma


Low energy
materials

Increased
Sustainable
human
site
comfort

Hotels
Superior
Water
indoor
reduction
quality

Waste Energy
management optimisation

PRESENTED BY: Nitin Sharma


GRIHA Certification

PRESENTED BY: Nitin Sharma


PRESENTED BY: Nitin Sharma
SITE PLANNING
Sustainable Site Development
Majority of associates travel by either public transport or use pooled vehicles.
All Hotels consciously promotes cultivation of native plants
More than one third of the Hotel roof area is with a special paint with high Solar
Reflective Index, thereby reducing the cooling demand.
Building Façade and Exterior hardscape is maintained without use of any chemicals.

Sanctioned Site plan should be conforming


to the following:

• Eco-sensitive zone regulations,


• Coastal zone regulations
• Heritage areas
• Water body zones
• Various hazard prone area regulations

PRESENTED BY: Nitin Sharma


Low-impact design
 Heat gain in design case be lower
than GRIHA base case.
 At least 50% of total external wall
area on unfavorable orientations
like West, are abutting buffer
zones/service areas.
 Cross ventilation in the naturally
ventilated/mixed- mode ventilation.
 Annual sun path/shading analysis.
 Conduct insolation analysis for summer months (typically April to June).
 Insolation has reduced by at least 25% through planting of dense trees next to
critical facades during Summer months (1st April to 30th June) – only in case of up to
G+3 structures.
 Site planning has been done according to site contours - for contours with slopes
equal to or greater than 1:4.
 Demonstrate at least 50% (by area) of such features on site must be preserved.
 Submit layout to demonstrate incorporation of appropriate SUDS strategies for
managing over 90% of the storm water quantity on site.
PRESENTED BY: Nitin Sharma
Design to mitigate Urban heat island effect
Site surfaces visible to sky are
• Soft paved/covered with high SRI coating (SRI > 0.5) OR
• Shaded by trees OR vegetated pergolas OR solar panels OR
• any combination of these strategies
Net Imperviousness factor of site meets the NBC 2005 norms & the post-construction
storm water discharge from the site is zero.

PRESENTED BY: Nitin Sharma


Construction Management
• 3 meter high barricading around the construction area.
• Wheel washing facility at the vehicular entrance.
• Covering off interaggregate and excavated earth.
• Water sprinkling on fine aggregate(sand) and excavated earth.
• For all DG sets, proper chimneys with outlet facing away from site
• Develop and implement a spill prevention plan (hazardous materials like

• Bitumen, diesel etc. on site.

•No existing mature tree is cut or


•Plant 3 trees for every 1 tree cut of the same native/naturalized species OR
•any combination of these for all mature trees on site
•Increase total number of trees on site by
•25% above the pre-construction phase OR
•Plant 4 trees for every 1 tree cut of the same native/naturalized species
•Preserve top soil during construction, maintain its fertility and use for landscape post-
construction

PRESENTED BY: Ataulla Khan


PRESENTED BY: Ataulla Khan
Energy Efficiency
Some Energy Saving initiatives:
Chiller Plant Optimizer
Heat-Pump System
Solar based Hot water & Steam System
Renewable Energy
LED Lighting
BMS System

Chiller plant optimizer

PRESENTED BY: Ataulla Khan


Solar Light poles
Solar parabolic collectors

PV Sheets

PRESENTED BY: Ataulla Khan


Energy efficient lighting (LED Lights for energy efficiency and Zero mercury content) and
light pollution reduction in all hotels.

All hotels have a network based building management system to monitor and control the
HVAC (Heating, Ventilation & Air Conditioning), Lighting, Sub-metering and water management
system.
Digital Valet System: IPAD operated room control system to control Air conditioning,
Lighting, TV etc.
Condensate recovery system

PRESENTED BY: Ataulla Khan


PRESENTED BY: Ataulla Khan
Energy Efficiency
Pressure Independent Control Valve system (PICV) for constant water pressure throughout the
building and AHU coils.
Remote monitoring & control system for all refrigerator temperature.
ITC Sonar is the first hotel to receive carbon credits in the world through the CDM (Clean
Development Mechanism) initiatives of UNFCCC (United Nations Framework Convention
on Climate Change).

PRESENTED BY: Ataulla Khan


Occupant comfort and Well-being

PRESENTED BY: Ataulla Khan


Artificial lighting levels

As per NBC & Uniformity ratio of 0.4


Meet thermal comfort requirements as per NBC/ASHRAE 55/Indian
- Mandatory adaptive comfort model
- Indoor noise levels not to exceed NBC prescribed levels

• CPCB National Ambient Air Quality Standard (NAAQS) for fresh air quality &
• ASHRAE 62.1-2010/NBC 2005 for fresh air quantity
• Treatment for Outdoor air for PM10 and PM2.5

• Monitoring CO2, Temperature and RH


• All Low-VOC interior paints.
• All Low-VOC adhesives & Sealants and no
use of urea-formaldehyde in composite
wood products

PRESENTED BY: Pranav Arora


Water saving techniques

Water Saving techniques:


Water efficient fixtures
Sewage Treatment Plants
Use of Treated water
Storm water management
Rain water harvesting

Sensor operated fixtures, waterless urinals, dual flush water closets and flow
restrictors (Aerators) for reducing water consumption against LEED® benchmark for
water consumption.
Only treated recycled water is used for flushing, landscape, cooling tower and
miscellaneous cleaning. Drip irrigation system for water efficient landscaping.
Segregation of Black and Grey water for Sewage treatment plant and waste water
recycling. Surplus water to neighbouring areas / communities gardens.
Rain Water Harvesting system to capture Roof and Non-roof rain water

PRESENTED BY: Pranav Arora


Water

PRESENTED BY: Pranav Arora


PRESENTED BY: Pranav Arora
Sustainable Building Materials

15% Replacement of OPC with fly ash in structural concrete • 25% Replacement of OPC
with fly ash in structural concrete
Use of fly-ash in 40% of building blocks/bricks
Reduction in combined embodied energy of load-bearing structure and masonry walls

PRESENTED BY: Pranav Arora


Solid Waste Management
•Dedicated,
Waste segregation at source
• segregated and hygienic storage space for different types of wastes
•Recycling of recyclable wastes (metal, paper, plastic, glass etc)
•Treat organic waste (Kitchen and landscape) on site to convert it into resource

PRESENTED BY: Pranav Arora


Socio-Economic Strategies
•Necessary safety equipment and measures for construction workers
•Drinking water, hygienic working & living conditions and sanitation facility for
construction workers

•Crèche facility for children of construction workers

Adopt measures to create environmental awareness

PRESENTED BY: Pranav Arora


Performance Monitoring & Validation

PRESENTED BY: Pranav Arora


Innovation

• A GRIHA certified professional involved in the project


• First Mover: Implementation of a technology for the first time
in the country.
• E-waste recycling
• STP technologies which do not use chemicals
• Net-Zero Energy/Water
• Provision of Electric charging points for Electric vehicles

PRESENTED BY: Pranav Arora


Case Study
ITC Hotel at Guntur
Project summary
The ITC Hotel building is located at Guntur. The building is of commercial use with 2
Basement floor + Ground floor+ 9 floors. This new commercial use building has an
approximate gross floor area approximate 238,722 square feet, and includes Guest
room, meeting room, reception, Gymnasium, Dining hall, kitchen, Restaurant. The net
air conditioned area of the project is approximate 89,652 square feet.

Modeling methodology
The Proposed Building has been evaluated on the basis of the methodology outlined
in Appendix G, The Performance Rating Method of ASHRAE/IESNA 90.1-2007. Visual
DOE 4.1, a front-end to the DOE-2.1E engine, has been used as the simulation tool.

Annual hourly energy simulations are performed to quantify the anticipated HVAC and
lighting energy savings of the proposed building design. The two building models
(Baseline and Proposed) use identical climate zones, layout, occupancy, plug loads, and
schedules.

PRESENTED BY: Sudhanshu Srivastava


Stereographic Diagram

PRESENTED BY: Sudhanshu Srivastava


Monthly Averages Data

PRESENTED BY: Sudhanshu Srivastava


Climate summary chart

PRESENTED BY: Sudhanshu Srivastava


Model images of the building from Visual DOE

PRESENTED BY: Sudhanshu Srivastava


Climate summary chart
The Baseline building is an ASHRAE 90.1-2007 compliant building based on the
requirements outlined in Appendix G of the Standard. The Baseline building residential
spaces System -2 Packaged terminal Air Conditioner and Non-residential spaces System
6 – Packaged rooftop VAV with reheat. Envelope requirements are based on the
ASHRAE minimum values for a building located in Climate Zone 1 – Hyderabad, India.
No external shading devices are included in the Baseline building model.

The Baseline building performance is the averaged results of simulating the building
with its actual orientation and after rotating the entire building 90, 180, and 270
degrees as ASHRAE 90.1 requires.

The proposed model incorporates all the energy efficient features as designed. The
energy cost savings between the baseline and proposed models is used to determine
the total number of LEED® credit points available under Energy and Atmosphere Credit
1 (EA1) - Optimize Energy Performance. The total number of EA1 points achievable for
the project under LEED_India_NC_2011 rating system is as under:

PRESENTED BY: Sudhanshu Srivastava


LEED_India_NC_2011 Point Distribution

PRESENTED BY: Sudhanshu Srivastava


PRESENTED BY: Sudhanshu Srivastava
PRESENTED BY: Sudhanshu Srivastava
PRESENTED BY: Sudhanshu Srivastava
Case Study
Grand Chola Hotel
at Chennai
Grand Chola, ITC Hotels Limited
Location : Chennai
Site Area : 32330 SqM
Total Built up Area : 132598 SqM
Air- conditioned Area : 132598 SqM
Non Air- conditioned Area : NA
Energy Consumption Reduction : 41.5% reduction from GRIHA benchmark
Water consumption reduction : 50.7% reduction from GRIHA benchmark EPI : 186
kWh/SqM/year
Occupancy hours : 24 hours/day (24x7)
Renewable energy installed on site : 12600 KWp (kilo watt peak)
GRIHA final rating : 5 Stars
he Grand Staircase of ITC Grand Chola . Image Courtesy:www.itc.in
Some of the features of this seven star green luxury hotel include:
600 super premium rooms with a built up area of close to 1.5 million square feet is the
World’s largest LEED Platinum rated hotel as of September 2012 @ Chennai, State of Tamil
Nadu.
Tall pillars of flowers greet you at the lobby. The hotel’s signature asset — a 30,000 sq.ft pillar
less ballroom — takes five minutes to walk across from end-to-end
Ten food and beverage outlets, a 23,000-sq.ft. Kaya Kalp spa and ‘iPad-controlled technology’
are other features of the hotel that has had Rs. 1,200 crore invested in it
ITC Grand Chola appointed workforce close to 4,000 people with over 1,000 people engaging
in day-to-day operations.
PRESENTED BY: Kumar Avinash
Grand Chola, ITC Hotels Limited
Seven star green luxury hotel include: Water consumption reduction : 50.7% reduction
600 super premium rooms with a built from GRIHA benchmark EPI : 186 kWh/SqM/year
up area of close to 1.5 million square feet Occupancy hours : 24 hours/day (24x7)
is the World’s largest LEED Platinum rated Renewable energy installed on site : 12600 KWp
hotel as of September 2012 @ Chennai, GRIHA final rating : 5 Stars
State of Tamil Nadu.
Location : Chennai
Site Area : 32330 SqM
Total Built up Area : 132598 SqM
Air- conditioned Area : 132598 SqM
Non Air- conditioned Area : NA
Energy Consumption Reduction : 41.5%
reduction from GRIHA benchmark

PRESENTED BY: Kumar Avinash


Sustainable Features of ITC Grand Chola
Sustainable Site Planning:
• Existing trees were preserved and transplanted along the periphery of the site
• Excavation and construction started after the monsoon season to prevent soil erosion
and soil run off from the site
• Top soil was preserved and re-used to raise the ground level along the periphery
• Service corridors are planned to cause minimum damage to the site and natural
topography
• Orientation of the building is east west but zoning of the building has been
appropriately done to reduce negative impact of bad orientation

Reduction in water consumption (compared to GRIHA benchmark):


• Reduction in building water consumption by use of low-flow fixtures : 50.7%
• Water recycled and reused within the complex : 90%
• Reduction in landscape water consumption by planting native species of trees and
shrubs and by using efficient
irrigation systems : 62.3%
Passive architectural design strategies adopted in the building:
• Thick stone and AAC block walls to reduce solar heat gain
• Recessed windows to cut direct sun rays and glare inside the building
• 99% of living areas are day-lit and window to wall ratio restricted to 25% to
reduce solar heat gain inside the building

PRESENTED BY: Kumar Avinash


Sustainable Features of ITC Grand Chola
Renewable energy technologies installed
on site:
Installed capacity of wind energy : 12600
KWp
Units of electricity generated annually :
27900000 KWh

Use of low-energy/green materials:


Use of Plywood and MDF boards
manufactured by Uniply, Greenply and
Centuryply certified by SGS and
recyclable fabric
Use of high density composite wood
panels

PRESENTED BY: Kumar Avinash


Sustainable Features of ITC Grand Chola
Reduction in energy consumption (compared to GRIHA
benchmark) while maintaining occupant comfort:
For achieving visual comfort n Energy efficient artificial
lighting design is compliant with ECBC recommendations
Occupancy sensors in rooms to reduce energy
consumption
All electrical fixtures (lights, space conditioners,
appliances) controlled by i-pad to reduce energy
consumption
External shading and efficient glazing to reduce solar
heat gain and have glare-free daylight have been
installed.
For achieving thermal comfort
Building envelope is ECBC compliant, which helps
reduce cooling loads in AC spaces and meets thermal
comfort levels in non AC spaces.
Centralized air conditioning through variable refrigerant
flow technology is installed. Facility of controlling each
indoor unit centrally as well as individually based on
occupancy censor is provided.
Use of AAC blocks in the infill wall system.

PRESENTED BY: Kumar Avinash


Thank you

Das könnte Ihnen auch gefallen