Sie sind auf Seite 1von 2

Delphi PST MARINE

Injector type
28280600 64/13 Moo 2 Kok kra beu
Reference Number Meung Samut sakorn
Old Grading Data Thailand 74000
New Grading Data
Date and Time 03/02/2020 10:21:42 034864224
QR Code
service@psrmarine.com

Calibration
Test comments Tata#1

Electrical
Parameter Min. Max. Value Units Status
Resistance 1 0.1 0.5 0.2 Ω
Inductance 1 0.1 0.4 0.14 mH

Flush

Maximum power
Parameter Min. Max. Value Units Status
Pressure 1782 1818 1800 bar
Response 300 450 366 µS
Delivery 53.1 64.1 57.61 mm3/st
Back leak flow 0 49.9 31.3 mL/min

Emissions
Parameter Min. Max. Value Units Status
Pressure 865 885 875 bar
Response 360 455 384 µS
Delivery 24.2 36.5 36.25 mm3/st
Back leak flow 0 22.5 15.9 mL/min

Pilot
Parameter Min. Max. Value Units Status
Pressure 1089 1111 1100 bar
Response 360 451 371 µS
Delivery 0.9 10 9.34 mm3/st
Back leak flow 0 16.2 9.6 mL/min
Idle
Parameter Min. Max. Value Units Status
Pressure 315 335 324 bar
Response 0 0 468 µS
Delivery 5 13.5 13.49 mm3/st
Back leak flow 0 5.2 3.6 mL/min

Static leak
Parameter Min. Max. Value Units Status
Pressure 990 1010 1001 bar
Response 0 0 0 µS
Delivery 0 0 0 mm3/st
Back leak flow 0 7 1.3 mL/min

Sv = 4.15 : Tv = Issue-15 : Fp = A262A902 : Fv = 1.31 : Rv = 1.09 : Lv = 3.00 :