U9000 ULTRAFILTER

Designed to produce ultrapure dialysis fluid*

* Intended to be used in conjunction with a water treatment system


U9000 ULTRAFILTER

INDICATIONS PERFORMANCES
The U9000 ultrafilter is indicated for purification of incoming water for dialysis Typical pressure drop
fluid as well as purification of dialysis fluid to obtain microbiological high quality
QF = 500 ml/min – dialysis fluid
dialysis fluid. The risk of exposure to bacteria and endotoxins can thereby
at temperature = 37°C < 100 mmHg
be minimized.
The U9000 ultrafilter is intended to be used in conjunction with a water
Lifetime
treatment system.
On the AK98 V2, V3 and Artis dialysis system:
The U9000 ultrafilter shall be changed after 3 months of usage or 150 disinfection
cycles, whichever comes first
MATERIALS
On the AK 96 and AK 98 V1 dialysis system:
Membrane PAES/PVP The U9000 ultrafilter shall be changed after 2 months of usage or 100 disinfection
Potting material Polyurethane (PUR) cycles, whichever comes first
Housing and caps Polycarbonate (PC) Maximum 12 disinfections with sodium hypochlorite over the lifetime of the U9000
Gasket Silicone rubber Maximum 8 disinfections with sodium carbonate over the lifetime of the U9000

CHARACTERISTICS Disinfection / decalcification


The U9000 ultrafilter is disinfected with the dialysis machine. Follow the disinfection
Effective membrane area (m²) 2.4
program recommended in the operator manual of the dialysis machine
Priming volume lumen (ml) 145
The U9000 ultrafilter is compatible with the following chemical agents:
Priming volume filtrate side (ml) 290 • Peracetic acid (≤0.1%)
Compatibility The U9000 ultrafilter is only compatible • Sodium carbonate (≤0.5%)
with the Baxter HD system equipped • Sodium hypochlorite (≤0.5%)
with the U9000 holder • Citric acid (≤2.0%)
The U9000 ultrafilter is compatible with heat disinfection
TYPICAL RETENTION VALUES
FOR BACTERIA AND ENDOTOXINS LRV* PRODUCT INFORMATION
Product code Designation Unit per box
Bacterial challenge: Pseudomonas
diminuta ATCC 19146 >7 112062 U9000 16
Endotoxin challenge: E. coli O55:B5 114604 U9000 APAC 16
endotoxin (Whittaker, USA) > 3.5

* LRV = log10 (number of organisms in challenge suspension/number of organisms in filtrate)

For safe and proper use of the device, please refer to the Instructions for Use

2797
renalcare.baxter.com
Baxter Healthcare Corporation
One Baxter Parkway
Deerfield, IL 60015
Baxter, AK 96, AK 98, Artis and U9000 are trademarks USA
of Baxter International Inc. or its subsidiaries EUMP/MG204/16-0001(1) – September 2019 1-800-422-9837