1.

0      PURPOSE
The purpose of this note is to present instrument and utility air demand calculations.

2.0       BASIS
The instrument and utility air demand is estimated based on the following
guidelines. The instrument air system capacity shall comply with Section 21 of API
RP 552 and ISA 7.0.01:

a) 1 3/5 standard cubic meter per hour (1.6Sm3/hr) shall be used for pneumatic instrument component (eg LIC, PIC,LSHH,
etc).

b)    Seventeen standard cubic meter per hour (17Sm3/hr) shall be allowed for air motors, piston-type positioners, purge, and
blowback requirements (PV,LV, SDV,BDV etc).

3.0    INSTRUMENT AND UTILITY AIR CONSUMERS

S/N Instrument Air Users P&ID Number


1.   33-UZV-101 F-511-G04-0002-001
2.   33-UZV-102 F-511-G04-0002-001
3.   33—LV-101 F-511-G04-0002-001
4.   33—PV-104 F-511-G04-0002-001
5.   34-UZV-101 F-511-G04-0004-001
6.   34-UZV-102 F-511-G04-0004-001
7.   34-UZV-103 F-511-G04-0004-001
8.   34-BDV-104 F-511-G04-0004-001
9.   34—LV-101 F-511-G04-0004-001
10.   34—PV-104 F-511-G04-0004-001
11.   34—PV-105A/B F-511-G04-0001-001
12.   34-UZV-105 F-511-G04-0004-001
13.   48-UZV-107 F-511-G04-0007-001
14.   50-PV-101 F-511-G04-0007-001
15.   Starting Air to Diesel Generator F-511-G04-0012-001
16.   Starting Air to Gas Generator F-511-G04-0013-001
17.   Gaslift Compressor F-511-G04-0003-001
18.   Utility Air Station F-511-G04-0005-001
Jisike Debotlenecking and Gaslift System Upgrade Project Utility Requirement Calculation

INSTRUMENT AIR DEMAND

Number of users Total Air Demand (Sm3/hr)


Normal Air
Instrument Air Users Demand per User
(Sm3/hr)
Continuous Intermittent Continuous Intermittent
33-UZV-101 17 - 1 - 17
33-UZV-102 17 - 1 - 17
33—LV-101 17 1 - 17 -
33—PV-104 17 1 - 17 -
34-UZV-101 17 - 1 - 17
34-UZV-102 17 - 1 - 17
34-UZV-103 17 - 1 - 17
34-BDV-104 17 - 1 - 17
34—LV-101 17 1 - 17 -
34—PV-104 17 1 - 17 -
34—PV-105A/B 17 1 - 17 -
34-UZV-105 17 - 1 - 17
48-UZV-107 17 - 1 - 17
50-PV-101 17 1 - 17 -
Starting Air to Diesel Generator 17 - 1 - 17
Starting Air to Gas Generator 17 - 1 - 17
Total Valve Instrument Air
Consumption 102 170

Total Demand (without


compressor package demand) 272

Peak Demand(Total
Deman+Assume 20%
Requirement for Compressor
Package
System+10%Contingencies) 353.6

* 10% contingency is used to account for uncertainty .