Sie sind auf Seite 1von 6

SAFETY MANAGEMENT SYSTEM MANUAL

CHAPTER 10
PANTHALASSA
REVISION No. 00
MARITIME CORP. E21
DIESEL GENERATOR PERFORMANCE REPORT

ONBOARD FOLDER No. 9A PERIODICITY: Monthly

VESSEL: ANGELIC GLORY DATE: 4/23/2020 D/G No. 1


GENERAL DATA
START TIME 0930 HRS END TIME 1030 HRS DURATION 1.000 HRS
EL. POWER 380 kW AMB. PRESS mbar S.W. TEMP. 19.0 0
C
D/G RPM 720 RPM AMB. TEMP.
0
C Rel. Humid. %
TYPE 5DK20 TOT. POWER kVA 2-X
SER.NO. DK520Z0809 NOM. POWER 574 kW 4-X
BORE: 200 mm VOLTAGE 440 V PF
STROKE: 300 mm CURRENT 430 A

CYLINDER PARAMETERS
PARAMETER NO.1 NO.2 NO.3 NO.4 NO.5 NO.6 NO.7 NO.8 Mean Max-Mean
MAX. PRESSURE (Kg/cm2) 114 113 114 113 114
COMP. PRESSURE(Kg/cm2)

INDIC. PRESSURE (Kg/cm2)

EXH. GAS OUTLET TEMP. (0C) 440.0 425.0 435.0 420.0 420.0
FUEL PUMP INDEX 22.0 21.0 22.0 21.0 21.0
F.W. JACKET OUTLET ( C)
0
67.0 68.0 68.0 67.0 66.0

TURBOCHARGER PARAMETERS NO.1 OTHER ENGINE PARAMETERS


TURBOCHARGER RPM PRESSURE EXH. GAS RECEIVER bar
TEMP. AIR - BLOWER INLET 0
C TEMP. EXH. GAS RECEIVER 460 0
C
TEMP. AIR - BEFORE COOLER 0
C 39.0 PRESSURE SCAVENGE AIR 1.1 bar
TEMP. AIR-AFTER COOLER 0
C 42.0 TEMP. SCAVENGE AIR 45 0C
TEMP. S.W.- AIR COOLER IN 0
C 65.0 LO PRESSURE ENGINE IN 4.8 bar
TEMP. S.W.- AIR COOLER OUT 0
C 59.0 LO TEMPERATURE ENGINE IN 61 0C
TEMP. EXH. GAS TURBINE IN 0
C 304.0 JACKET COOL FW PRESSURE 3.4 bar

Page 1 of 6
SAFETY MANAGEMENT SYSTEM MANUAL
CHAPTER 10
PANTHALASSA
REVISION No. 00
MARITIME CORP. E21
DIESEL GENERATOR PERFORMANCE REPORT

TEMP. EXH.GAS TURBINE OUT 0


C 289.0 JACKET COOL FW TEMP. IN 62 0C
AIR COOLER PRESS. DROP mmWG JACKET COOL FW TEMP. OUT 70 0C
AIR FILTER PRESSURE DROP mmWG GENERATOR BEARING TEMP. 0
C
PRESSURE EXH. GAS AFTER T/C mmWG ENGINE BEARING LO PRESSURE bar
T/C OIL PRESSURE bar 3.7
FUEL DENSITY 15C kg/m 3
START END Difference Temp Dens FUEL
VISCOSITY 50C cSt ltrs ltrs ltrs 0
C kg/lt KG
FUEL CCAI FLOW IN
FUEL HEAT VALUE kJ/kg FLOW OUT
FUEL TEMP ENG. IN 0
C IHP kW Consumption
BOOSTER PRESS bar BHP kW nm
LOAD %
FUEL INDEX bar EL.POWER kW ne
GOVERNOR INDEX SFOC gr/kWh ISO CORR. SFOC gr/kWh
LOAD INDICATOR LO CONS. l/24hrs SPECIFIC LO CONS. gr/kWh

COMMENTS:

CHIEF ENGINEER:
NAME / SIGNATURE

Page 2 of 6
SAFETY MANAGEMENT SYSTEM MANUAL
CHAPTER 10
PANTHALASSA
REVISION No. 00
MARITIME CORP. E21
DIESEL GENERATOR PERFORMANCE REPORT

ONBOARD FOLDER No. 9A PERIODICITY: Monthly

VESSEL: ANGELIC GLORY DATE: 4/27/2020 D/G No. 2


GENERAL DATA
START TIME 1000 HRS END TIME 1100 HRS DURATION 1.000 HRS
EL. POWER 380 kW AMB. PRESS mbar S.W. TEMP. 21.0 0
C
D/G RPM 720 RPM AMB. TEMP.
0
C Rel. Humid. %
TYPE 5DK20 TOT. POWER kVA 2-X
SER.NO. DK520Z0809 NOM. POWER 574 kW 4-X
BORE: 200 mm VOLTAGE 440 V PF
STROKE: 300 mm CURRENT 500 A

CYLINDER PARAMETERS
PARAMETER NO.1 NO.2 NO.3 NO.4 NO.5 NO.6 NO.7 NO.8 Mean Max-Mean
MAX. PRESSURE (Kg/cm2) 114 114 114 113 114
COMP. PRESSURE(Kg/cm2)

INDIC. PRESSURE (Kg/cm2)

EXH. GAS OUTLET TEMP. (0C) 445.0 430.0 435.0 430.0 435.0
FUEL PUMP INDEX 22.0 21.0 22.0 21.0 22.0
F.W. JACKET OUTLET ( C)
0
68.0 68.0 69.0 68.0 67.0

TURBOCHARGER PARAMETERS NO.1 OTHER ENGINE PARAMETERS


TURBOCHARGER RPM PRESSURE EXH. GAS RECEIVER bar
TEMP. AIR - BLOWER INLET 0
C TEMP. EXH. GAS RECEIVER 450 0
C
TEMP. AIR - BEFORE COOLER 0
C 39.0 PRESSURE SCAVENGE AIR 1.0 bar
TEMP. AIR-AFTER COOLER 0
C 42.0 TEMP. SCAVENGE AIR 46 0C
TEMP. S.W.- AIR COOLER IN 0
C 65.0 LO PRESSURE ENGINE IN 4.8 bar
TEMP. S.W.- AIR COOLER OUT 0
C 59.0 LO TEMPERATURE ENGINE IN 61 0C
TEMP. EXH. GAS TURBINE IN 0
C 304.0 JACKET COOL FW PRESSURE 3.4 bar

Page 3 of 6
SAFETY MANAGEMENT SYSTEM MANUAL
CHAPTER 10
PANTHALASSA
REVISION No. 00
MARITIME CORP. E21
DIESEL GENERATOR PERFORMANCE REPORT

TEMP. EXH.GAS TURBINE OUT 0


C 289.0 JACKET COOL FW TEMP. IN 62 0C
AIR COOLER PRESS. DROP mmWG JACKET COOL FW TEMP. OUT 70 0C
AIR FILTER PRESSURE DROP mmWG GENERATOR BEARING TEMP. 0
C
PRESSURE EXH. GAS AFTER T/C mmWG ENGINE BEARING LO PRESSURE bar
T/C OIL PRESSURE bar 3.7
FUEL DENSITY 15C kg/m 3
START END Difference Temp Dens FUEL
VISCOSITY 50C cSt ltrs ltrs ltrs 0
C kg/lt KG
FUEL CCAI FLOW IN
FUEL HEAT VALUE kJ/kg FLOW OUT
FUEL TEMP ENG. IN 0
C IHP kW Consumption
BOOSTER PRESS bar BHP kW nm
LOAD %
FUEL INDEX bar EL.POWER kW ne
GOVERNOR INDEX SFOC gr/kWh ISO CORR. SFOC gr/kWh
LOAD INDICATOR LO CONS. l/24hrs SPECIFIC LO CONS. gr/kWh

COMMENTS:

CHIEF ENGINEER:
NAME / SIGNATURE

Page 4 of 6
SAFETY MANAGEMENT SYSTEM MANUAL
CHAPTER 10
PANTHALASSA
REVISION No. 00
MARITIME CORP. E21
DIESEL GENERATOR PERFORMANCE REPORT

ONBOARD FOLDER No. 9A PERIODICITY: Monthly

VESSEL: ANGELIC GLORY DATE: 4/29/2020 D/G No. 3


GENERAL DATA
START TIME 0930 HRS END TIME 1030 HRS DURATION 1.000 HRS
EL. POWER 380 kW AMB. PRESS mbar S.W. TEMP. 21.0 0
C
D/G RPM 720 RPM AMB. TEMP.
0
C Rel. Humid. %
TYPE 5DK20 TOT. POWER kVA 2-X
SER.NO. DK520Z0809 NOM. POWER 574 kW 4-X
BORE: 200 mm VOLTAGE 440 V PF
STROKE: 300 mm CURRENT 130 A

CYLINDER PARAMETERS
PARAMETER NO.1 NO.2 NO.3 NO.4 NO.5 NO.6 NO.7 NO.8 Mean Max-Mean
MAX. PRESSURE (Kg/cm2) 113 113 114 113 114
COMP. PRESSURE(Kg/cm2)

INDIC. PRESSURE (Kg/cm2)

EXH. GAS OUTLET TEMP. (0C) 440.0 430.0 435.0 430.0 435.0
FUEL PUMP INDEX 21.0 22.0 23.0 21.0 21.0
F.W. JACKET OUTLET ( C)
0
68.0 68.0 68.0 67.0 68.0

TURBOCHARGER PARAMETERS NO.1 OTHER ENGINE PARAMETERS


TURBOCHARGER RPM PRESSURE EXH. GAS RECEIVER bar
TEMP. AIR - BLOWER INLET 0
C TEMP. EXH. GAS RECEIVER 450 0
C
TEMP. AIR - BEFORE COOLER 0
C 39.0 PRESSURE SCAVENGE AIR 1.1 bar
TEMP. AIR-AFTER COOLER 0
C 42.0 TEMP. SCAVENGE AIR 46 0C
TEMP. S.W.- AIR COOLER IN 0
C 65.0 LO PRESSURE ENGINE IN 4.8 bar
TEMP. S.W.- AIR COOLER OUT 0
C 59.0 LO TEMPERATURE ENGINE IN 61 0C
TEMP. EXH. GAS TURBINE IN 0
C 304.0 JACKET COOL FW PRESSURE 3.4 bar

Page 5 of 6
SAFETY MANAGEMENT SYSTEM MANUAL
CHAPTER 10
PANTHALASSA
REVISION No. 00
MARITIME CORP. E21
DIESEL GENERATOR PERFORMANCE REPORT

TEMP. EXH.GAS TURBINE OUT 0


C 289.0 JACKET COOL FW TEMP. IN 62 0C
AIR COOLER PRESS. DROP mmWG JACKET COOL FW TEMP. OUT 70 0C
AIR FILTER PRESSURE DROP mmWG GENERATOR BEARING TEMP. 0
C
PRESSURE EXH. GAS AFTER T/C mmWG ENGINE BEARING LO PRESSURE bar
T/C OIL PRESSURE bar 3.7
FUEL DENSITY 15C kg/m 3
START END Difference Temp Dens FUEL
VISCOSITY 50C cSt ltrs ltrs ltrs 0
C kg/lt KG
FUEL CCAI FLOW IN
FUEL HEAT VALUE kJ/kg FLOW OUT
FUEL TEMP ENG. IN 0
C IHP kW Consumption
BOOSTER PRESS bar BHP kW nm
LOAD %
FUEL INDEX bar EL.POWER kW ne
GOVERNOR INDEX SFOC gr/kWh ISO CORR. SFOC gr/kWh
LOAD INDICATOR LO CONS. l/24hrs SPECIFIC LO CONS. gr/kWh

COMMENTS:

CHIEF ENGINEER:
NAME / SIGNATURE

Page 6 of 6

Das könnte Ihnen auch gefallen