Release Notes
GE Publication Number: GER-4458
Copyright © 2012 GE Multilin
Overview
Summary
GE Digital Energy releases the Multilin 369 Motor Management Relay Firmware version 3.62 and Multilin
EnerVista 369 Motor Management Relay Setup Software version 4.23.
Highlights of the EnerVista 369 Setup Software release version 4.23 include:
The latest version of the Multilin 369 Setup software and Firmware can be downloaded from the GE
Digital Energy website at:
http://www.gedigitalenergy.com/multilin/software/369.htm
Please contact your local GE sales representative or Multilin Customer Service Department (CST) for
any questions regarding this upgrade.
GE Digital Energy 1
SR369 FW v3.62 & SW v4.23 Release Notes
Release details
In the following enhancement descriptions, a revision category letter is placed to the left of the description. Refer
to the Appendix at the end of this document for a description of the categories displayed.
With previous firmware versions of the Multilin 369 Motor Management Relay (Firmware versions 3.61
and earlier), the accumulated energy value shown on the front display would either be the MWh or KWh
part of the accumulated energy value. For example, an energy value of 122.889 MWh would be
displayed as 122 MWh when MWh is selected as display preference for energy or 889 KWh when KWh
was the selected as display preference for energy.
Firmware version 3.62 enhances this accumulated energy display by showing both the MWh and KWh
values together on the front panel display. Therefore, using the above example, the Multilin 369 front
panel display will now show 122.889 MWh when MWh is the selected as display preference for energy or
122889 KWh when KWh is the selected as display preference for energy
In previous versions of the Multilin 369 Setup Software (versions 4.21 and prior), if a customer ordered
and/or factory installed modification (“MOD”) was installed in the device, then the following settings will be
displayed as read only. In addition, these settings would not be written to the device while writing an offline
settings file to an online device. The affected settings are as follows:
“Ground CT Type” in “Current Transformer” screen
“Trip Relay Operation” in “Local Output Relays” screen
“Aux1 Relay Operation” in “Local Output Relays” screen
“Aux2 Relay Operation” in “Local Output Relays” screen
“Alarm Relay Operation“ in “Local Output Relays” screen
Multilin EnerVista 369 setup software version 4.23 has been enhanced to allow read or write of the
above mentioned settings. These settings will also be written to the device while writing an offline
settings file to an online device.
In previous versions of the Multilin EnerVista 369 Setup Software (versions 4.21 and prior), if the
‘usermap’ was saved then re-opened through the Usermap Screen, data would be arranged incorrectly,
compared to how it was originally entered.
Version 4.23 of the Multilin EnerVista 369 Setup Software corrects this issue.
2 GE Digital Energy
SR369 FW v3.62 & SW v4.23 Release Notes
In previous versions of the Multilin EnerVista 369 Setup Software (versions 4.21 and prior), the following
settings were disabled over the serial interface. These settings can be found through SETTINGS > S1
SETUP > COMMS screen.
The specific settings are as follows:
CHANNEL 1 Baud Rate
CHANNEL 1 Parity
CHANNEL 2 Baud Rate
CHANNEL 2 Parity
CHANNEL 3 Application
CHANNEL 3 Connection
CHANNEL 3 Baud Rate
CHANNEL 3 Parity
Version 4.23 of the Multilin EnerVista 369 Setup Software, corrects this issue, with the above settings now
be enabled when using a serial interface to communicate with a Multilin 369 Motor Management Relay.
Upgrade paths
Customers are able to upgrade their version of the Multilin 369 Setup software to the new version 4.23
release for free. This can be done either via the Multilin EnerVista Launchpad application or by direct
download from the following GE Digital Energy site:
http://www.gedigitalenergy.com/multilin/software/369.htm
If using EnerVista Launchpad, follow these steps:
1. Open EnerVista Launchpad
2. Click “IED Setup”
3. Click “Check Updates”. Note: this will check for updates to all of the IED setup software shown.
4. Select the 369 Firmware version 3.62 upgrade for download.
Please contact your local GE sales representative or Multilin Customer Service Department (CST) for
any questions regarding this upgrade.
GE Digital Energy 3
SR369 FW v3.62 & SW v4.23 Release Notes
Appendix
Change categories
This document uses the following categories to classify the changes.
Table 1: Revision categories
N New feature A separate feature added to the relay. Changes to existing features even
if they significantly expand the functionality are not in this category
G Change A neutral change that does not bring any new value and is not correcting
any known problem
D Changed, incomplete or false Changes to, or problems with text messages, LEDs and user pushbuttons
faceplate indications
R Changed, incomplete or false relay Changes to, or problems with relay records (oscillography, demand, fault
records reports, etc.)
C Protocols and communications Changes to, or problems with protocols or communication features
P Protection out of specification Protection operates correctly but does not meet published specifications
(example: delayed trip)
The revision category letter is placed to the left of the change description.
Technical Support
Contact information and call center for product support is shown below:
GE Digital Energy – Grid IQ Center
650 Markland Street
Markham, Ontario
Canada L6C 0M1
Telephone: 905-927-7070 or 1-800-547-8629 (North America), +34 94 485 88 00 (Europe)
Fax: 905-927-5098 (North America), +34 94 485 88 45 (Europe)
(North America), +34 94 485 88 45 (Europe)
E-mail: multilin.tech@ge.com
Home Page: www.GEDigitalEnergy.com/Multilin
4 GE Digital Energy