Beruflich Dokumente
Kultur Dokumente
CONVENTIONAL SYSTEMS
OPERATOR PANELS FOR CONVENTIONAL SYSTEMS .......................................................................... 9
DELTA COMPACT CONTROL PANELS - CONVENTIONAL ................................................................... 10
DELTA SUB PANELS, DECENTRALIZED - CONVENTIONAL ................................................................. 10
DETECTORS – CONVENTIONAL RANGE ............................................................................................... 11
BASES FOR CONVENTIONAL ORBIS DETECTORS .............................................................................. 12
MANUAL CALL POINTS CONVENTIONAL SYSTEMS ............................................................................ 13
OPERATOR PANELS FOR ADDRESSABLE SYSTEMS.......................................................................... 14
ADDRESSABLE SYSTEMS
DELTA COMPACT CONTROL PANELS - ADDRESSABLE ..................................................................... 14
DELTA SUB PANELS, DECENTRALIZED – ADDRESSABLE.................................................................. 15
DETECTORS – IQ8QUAD RANGE ........................................................................................................... 16
DETECTORS – IQ8QUAD RANGE WITH INTEGRATED ALARM DEVICES ........................................... 18
BASES FOR ADDRESSABLE IQ8QUAD DETECTORS ........................................................................... 20
MANUAL CALL POINTS FOR ADDRESSABLE SYSTEMS...................................................................... 21
I/O and ADDRESS UNITS ......................................................................................................................... 22
ALARM DEVICES
ALARM DEVICES – ACOUSTICAL – MED approved ............................................................................... 36
ALARM DEVICES – OPTICAL .................................................................................................................. 37
LOOP POWERED ALARM DEVICES ....................................................................................................... 38
EX ALARM DEVICES ................................................................................................................................ 39
MISCELLANEOUS
NETWORK and COMMUNICATION MODULES ....................................................................................... 44
ACCESSORIES ......................................................................................................................................... 45
DETECTOR LABELS................................................................................................................................. 47
Sales
Our products are distributed through a worldwide network of dedicated partners, agents and/or distributors, offering
our global operating customers local support and technical know how. Please contact our local partner in your
region for prices, contact information is found on the Eltek by Honeywell marine WEB site (www.eltek-fs.com).
Engineering
Our marine engineering department provides tailor-made solutions based on customer inputs, class requirements
and system design. The demand for safety, reliability and user friendliness is always considered. This requires
know-how built up during decades through our engagement in the marine market.
Field Service
Honeywell Life Safety AS is represented worldwide through a network of highly skilled and authorized partners
providing system sales, system design, commissioning, service and after sales support to ship owners and ship
yards. On-site service is also provided by a dedicated team of Field Service Engineers ready to travel on short
notice to any regions of the world.
For online support your find TechZone on our webpage www.eltek-fs.com which is an internet service for the
distribution of technical publications and other information. As a VIP-member you will get access to publications
concerning installation, service guidelines, operation, trouble- shooting, other technical documents and the
opportunity to download software.
----------------------------------------------------------------------------------------------------------------------------------------
Marine approvals
Our products for marine applications are approved by the major classification societies; hence both our
production is evaluated and subsequently our deliveries are suited for the environmental conditions that might
occur onboard. Please check our internet site for more information on the type approvals for our Marine
products.
By choosing an Eltek Fire & Safety branded Fire Detection and Alarm Solution from Honeywell Life Safety you
obtain a system with increased safety focus, reduced installation cost, easy maintenance, less spare parts and a
solution which compliance with the various requirements for fire system applications. From the same basic
modules we provide customised system solutions to suit your needs.
The embedded DELTA Technology has the unique features you would find in all the Eltek Fire & Safety branded
Fire Detection and Alarm System. Self-developed, cutting-edge technology offers users unsurpassed safety with
flexibility for future upgrading and expansion. The system philosophy enables communication between different
products and platforms. The result is maximum safety, greater user friendliness and maximal overall economy.
The Delta System support both Esser and Apollo detector loop protocols.
Our products for marine applications are approved by the major classification societies; hence both our production
is evaluated and subsequently our deliveries are suited for the environmental conditions that might occur onboard.
Please check our internet site for more information on the type approvals for our Marine products.
Delta Technology:
An expression covering Eltek Fire & Safety branded modular Fire Detection and Alarm Systems - EN54 compatible
and marine approved system components utilizing the latest technology in network systems and alarm signal
evaluation.
Delta Compact:
Eltek Fire & Safety' branded Fire Alarm Panel, featuring in one cabinet the following modules as standard: Delta
OP, Delta DA and batteries.
Delta NET:
Fire Alarm Network where Delta Modules communicate via 2 two wire cables, where one is used as an Emergency
Alarm Line (Hard Wire) and the other as an eBus.
eBus:
LON based bus for multi-master network communication between the Delta Modules. The eBus network is based
on intelligent control nodes (eNodes) that communicate with each other via eComm.
eComm:
Proprietary communication protocol for Delta Modules connected to the multi-master and eBus network.
eNode:
This Communication Unit is used for connecting other products such as a PC to the Delta Fire Detection and Alarm
Systems. The eNode is also used as an interface unit for other fire alarm modules connected to the multi-master
eBus network, or if you need to connect the Delta System Modules in a redundant network (double eBus network)
Small and elegant operating panel for recess mounting into consoles.
Protrudes 10 mm above its surroundings. The Delta OP small conforms to the
requirements for operating-units in fire-alarm networks
Communication:
Art. no. 251242 Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
Communication:
Art. no. 251241
Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc
The operating panel is primarily used as an operating unit in Delta network system.
The Delta OP meets the NS-EN-54.2.
Features:
graphic display,
output for programmable control of 64 LED’s,
Art. no. 251157.1 Incorporates communication port for eBus or RS 485.
Input for direct PC programming of connected units
Communication:
Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
The Delta Compact is a centralised fire detection and alarm control unit that complies with
EN 54.2 and EN 54.4. The unit consists of DELTA OP control panel, DELTA DA module
(incl. power-supply), eBus and batteries for emergency operation
Features:
5 loops,
3 monitored voltage outputs (e.g. alarm circuits),
Art. no. 251808.100 2 voltage-free relay outputs
1 monitored multi-function output.
Features:
5 zones,
Art. no. 251072.5 4 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
The Delta unit is a decentralized fire detection and alarm control unit that complies with EN
54.2 and EN 54.4. The unit may be used together with the DELTA OP or as either a stand
alone control unit in a network. The Delta unit consist of a Delta DA module (incl. power-
supply), eBus and batteries.
Features:
10 zones,
Art. no. 251073.10 4 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
Features:
5 conventional zones*,
4 monitored voltage outputs (e.g. alarm-bell circuits),
Art. no. 251245.2 2 voltage-free relay outputs
1 eBus (LON-kit)
IP 65
Internal dia: 100,5mm
Useful internal depth: 30mm
Material: Polycarbonate
Weight. 100g
Supplied with: 2x self tapping 4,2x16 screws, gasket, 3xPG16 glands, 1xPG16 plug.
Art. no. 235562
Note: Mounting Frame (251437) can be used in flush mounted application. Not mandatory.
Sealed Manual Call Point. Resistor Kit included (220, 470, 680, 1K8). 1 pcs Cable Gland
The Cable of PG16STR type (06-12 mm) is enclosed in the package. PG16ST (09-14mm)
glands can be ordered on article#: 10764.
Protection Cover
Cover for manual call point (fit article# 251615)
Communication:
Art. no. 251242 Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
The operating panel is primarily used as an operating unit in Delta network system.
The Delta OP meets the NS-EN-54.2.
Features:
graphic display,
output for programmable control of 64 LED’s,
Art. no. 251157.1 Incorporates communication port for eBus or RS 485.
Input for direct PC programming of connected units
Communication:
Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
The Delta Compact is a centralised fire detection and alarm control unit that complies with
EN 54.2 and EN 54.4. The unit consists of DELTA OP control panel, DELTA DA module
(incl. power-supply), eBus and batteries for emergency operation.
Features:
2 loops,
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
Art. no. 251062.100 1 monitored multi-function output.
Features:
2 analogue loops,
Art. no. 251809.2 3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
Features:
4 analogue loops,
Art. no. 251809.4 6 monitored voltage outputs (e.g. alarm circuits),
4 voltage-free relay outputs
2 monitored multi-function output.
The Delta unit is a decentralized fire detection and alarm control unit that complies with EN
54.2 and EN 54.4. The Delta unit consist of a Delta DA module (incl. power-supply), eBus
and batteries. Solid Rittal cabinet with gable gates for professional installation
Features:
4 analogue loops,
6 monitored voltage outputs (e.g. alarm circuits),
4 voltage-free relay outputs
Art. no. 251814.4
2 monitored multi-function output.
The Delta unit is a decentralized fire detection and alarm control unit that complies with EN
54.2 and EN 54.4.. The Delta unit consist of a Delta DA module (incl. power-supply), eBus
and batteries. Solid Rittal cabinet with gable gates for professional installation
Features:
6 analogue loops,
9 monitored voltage outputs (e.g. alarm circuits),
6 voltage-free relay outputs
Art. no. 251814.6
3 monitored multi-function output.
Features:
2 analogue loops,
Art. no. 251800.21 3 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
1 eBus (LON-kit)
The new and unique IQ8Quad detector generation combines unique detection technology with high class design and
set new standards in terms of appearance, safety and effectiveness. The IQ8Quad Detector range provides security
you need by implementing detection, optical alarm, acoustical alarm and voice alarm embedded in one housing.
IQ8QUAD is by far the most advanced detector range in the marine market. All versions are equipped with a 360
degree visual alarm indicator and non volatile memory log for all events.
Features:
-wide angle optical chamber with signal processing for fast and reliable smoke detection
Art. no. 802371. MAR
Features:
Art. no. 802374.MAR - detection using the forward and backward scatter principle
- advanced dual chamber signal processing for unparalleled false alarm rejection
Features:
Art. no. 802473 - wide angle optical chamber with signal processing for fast and reliable smoke detection
- CO detection element contributes to faster response to glowing fire starts.
Features:
- constant response behaviour for detecting slowly and quickly rising temperatures
Art. no. 802171
Features:
Art. no. 802271 - ROR feature ensures fast response to slowly and quickly rising temperatures
The IQ8Quad smoke detectors with built-in alarm device incorporate up to 4 different functionalities depending on the
type of detector:
ALARM SIGNALING
The alarm signaling function is activated by the control panel. No further short address needs to be allocated. It
is programmed with the FireWin Explorer commissioning and configuration application.
The sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) to approximately 92dB (A).
Multisensor detector with two built-in optical smoke sensors with different scattered light
angles as well as additional heat detector sensor evaluation for detecting everything from
smouldering fires to open fires with consistent response behaviour. Smoke signal
identification to ensure smoke classification and reduction of deceptive alarms caused, for
instance, by water vapour or dust
Art. no. 802383
Features:
-detection using the forward and backward scatter principle
-loop powered optical alarm signalling device
-advanced dual chamber signal processing for unparalleled false alarm rejection
-integrated optical alarm device
Multisensor detector with two built-in optical smoke sensors with different scattered light
angles as well as additional heat detector sensor evaluation for detecting everything from
smouldering fires to open fires with consistent response behaviour. Smoke signal
identification to ensure smoke classification and reduction of deceptive alarms caused, for
instance, by water vapour or dust.
Art. no. 802384.MAR
Features:
-detection using the forward and backward scatter principle
-loop powered optical alarm signalling device
-advanced dual chamber signal processing for unparalleled false alarm rejection
-integrated optical alarm device
-soft-start mode for protection against sudden exposure to acoustic alarm signalling
Features
-soft-start mode for optimum protection against sudden exposure to acoustic alarm
--detection using the forward and backward scatter principle
-loop powered optical alarm signalling device
-advanced dual chamber signal processing for unparalleled false alarm rejection
-integrated optical and acoustical alarm device
IQ8 base
Detector base with relay contact output for the IQ8 detectors range.
Contact: floating NO.
Note: Not to be used with IQ8QUAD detectors with integrated alarm device
Detector base with relay contact output for the IQ8 detectors range.
Contact: floating NC.
Note: Not to be used with IQ8QUAD detectors with integrated alarm device
Art. no. 805591.01
Art. no. 805572 Note: 3 pcs of Cable gland PG18STR type (6 –12mm) are included with the base. Cable
gland PG16ST type (9 -14 mm) can be ordered as art.no.:10764
IQ8 Base Adapter for flush mounting in polished stainless steel for recess installation of
IQ8 detectors. The adapter is supplied with springs for fixing the box in false ceilings and
cable entry in the bottom with rubber grommet.
Transparent plastic cover to be used together with art.no 804971 for IP55 application
Art. no. 704965
Mounting Frame for IQ8 Manual Call Point
Mounting Frame can be used in flush mounted application.
Not mandatory.
IP rating: 55
6 x PG 13,5mm cable glands
Art. no. 251595
Size: 11x15x15 cm.
Product Catalogue Eltek F&S Marine 22 (52)
Equipment for Special Applications
An address module to be used when connection article# 242923 and 242963.01 to a Delta
Esser System.
Note: Has to be used together with Delta DA Apollo (Art. no. 251244.1)
Art. no. 235580.003
Features:
Art. no. 233005 Supervising angle 100º
Current in stby: 0,12mA
Operating temperature -25ºC to +70ºC
NB! Utgått
Ambient humidity 0 to 95% RH
Features:
Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces
Reduces cabling, no interface required
Art. no. 243019.100 No additional power source required
Easy installation, uses a common plug in base for smoke and heat detectors
The unit consists of a 230VAC/12VDC converter and the refurbishment transponder unit art
Art. no. 251811.10 no 808630.
Art. no. 251813.11 The unit consists of a 24VDC/12VDC converter and the refurbishment transponder unit art
no 808630.
The Delta Logic Controller allows even more complex sectioning in the Delta architecture.
A logical expression can be built with logical AND and OR blocks with up to 3 inputs and
a NOT block with one input. As inputs you will have alarm, pre-alarm, isolation and fault
messages from systems, loops, detectors and transponders (I/O) available in addition to
outputs from other logical expressions and timers. The logical expressions can be
Art. no. 251850 programmed by using the Windows based configuration application Firewin Explorer.
Loop powered
Sensitive to stationary flames and hydrogen fires
Sensitivity
The UV flame detector is designed to operate to Class 1 performance as defined in
EN54: Part 10. The detector will, therefore, detect a flame of approximately 0.1m² or a
clear flame of 0.25m² at 25m.
Field of view
3
The IR flame detector has a viewing angle of view of approximately 90°
Sensitivity setting
The sensitivity switch is available and is used to set the sensitivity of the UV flame
detector to Class 1 or Class 3.
Environmental data
Operating temperature –40°C to +70°C
Relative humidity 95% (no condensation)
IP rating 66
Loop powered
Sensitivity
2
The UV/IR flame detector is designed to operate to Class 1 performance as defined
in EN54: Part 10. The detector will, therefore, detect a yellow flickering flame of
approximately 0.1m² or a clear flame of 0.25m² at 25m.
Field of view
3
The IR flame detector has a viewing angle of view of approximately 90°
Sensitivity setting
The sensitivity switch is available and is used to set the sensitivity of the flame
detector to Class 1 or Class 3.
Environmental data
Operating temperature –40°C to +70°C
Relative humidity 95% (no condensation)
IP rating 66
Current 2.2mA
The detectors are automatically coded when they are mounted onto the base. A
Art. no. 235101 replaceable plastic key contains a code that tells the detector where it is placed in the
Art. no. 235140 (key card) sequence of numbers. This means that the detector can be replaced
without addressing the detector itself.
Art. no. 235128 w/isolator
Art. no. 235101.001 w/relay
The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It
is a stainless steel mounting bracket adjustable in two axis.
Allows flame detector to be adjusted to the desired angle according to the monitored
area or object
IP 65
Internal dia: 100,5mm
Useful internal depth: 30mm
Material: Polycarbonate
Weight. 100g
Supplied with: 2x self tapping 4,2x16 screws, gasket, 3xPG16 glands, 1xPG16 plug.
Art. no. 235562
in normal conditions
with a single fault — for «ib» classification
with any combination of two faults — for «ia» classification
In any of these conditions, every component must remain cool enough to not ignite the gases for which it is
approved. The I.S. technique restricts the useful power to about 1W, which is sufficient for most modern
instrumentation. It is also safe for personnel, since the voltages are low and it allows field equipment to be
maintained and calibrated «live», without the need to obtain a gas-free certificate.
Features:
Art. no. 803374.EX - detection using the forward and backward scatter principle
- advanced dual chamber signal processing for unparalleled false alarm rejection
Features:
-wide angle optical chamber with signal processing for fast and reliable smoke detection
Art. no. 803371.EX
Features:
Art. no. 803271.EX - ROR feature ensures fast response to slowly and quickly rising temperatures
IQ8 base
Art. no. 805572 Note: 3 pcs of Cable gland PG18STR type (6 –12mm) are included with the base. Cable
gland PG16ST type (9 -14 mm) can be ordered as art.no.:10764
Conventional
IP rating: 66
The EXi MEDC manual call point can be connected directly to a DA module or an address
Art. no 251561 module, 804869, through zener barrier, 07096/2.
Conventional
IP rating: 67
Atex certified
The KAC manual call point can be connected directly to a DA module or an address module,
Art. no. 251617.Ex 804869, through zener barrier, 07096/2. Sealed Manual Call Point. 1 pcs Cable Gland
PG16STR type (06-12 mm) is enclosed in the package. PG16ST (09-14mm) glands can be
ordered on article#: 10764.
Conventional
IP rating: 66
For use in IS circuits as Simple Apparatus. No Atex approvals
The KAC manual call point can be connected directly to a DA module or an address module,
Art. no. 251617 804869, through zener barrier, 07096/2. Sealed Manual Call Point. 1 pcs Cable Gland
PG16STR type (06-12 mm) is enclosed in the package. PG16ST (09-14mm) glands can be
ordered on article#: 10764.
The 601FEx-M is a full featured solar blind flame detector for enclosed use and boasts a
high degree of false alarm immunity. The 601FEx-M is an intrinsically safe version intended
for use in hazardous atmospheres.
Unlike UV and UV/IR detectors, it is not blinded by oil mist in machinery spaces
Reduces cabling, no interface required
Delivered complete with sealed base
Art. no. 243019.200
The 601FEx-M can be connected directly to a DA module through zener barrier 07096/2, or
to an Address unit for conventional detectors, 251811.10 or 251813.10 through zener barrier
07099.
Conventional Manual call points must be connected to the addressable detector loop by an
address unit and a Zener barrier.
The unit is meant for DIN rail mounting. It can also be mounted in enclosure article 251595
Art. no. 804869 (see page 22)
This Zener Barrier is used when conventional EX manual call points are connected directly
to the conventional zones on the Delta Detection and Alarm Module (Delta DA) or to an
Address unit for EX manual call points (804869)
Art. no. 07096/2
The unit is meant for DIN rail mounting. It can also be mounted in enclosure article 251595
(see page 22)
This Zener Barrier is used when conventional EX Detectors are connected directly to the
conventional zones on the Delta Detection and Alarm Module (Delta DA) or to an Address
Art. no. 07099 unit for conventional detectors (251811.10)
The unit is meant for DIN rail mounting. It can also be mounted in enclosure article 251595
(see page 22)
The addressable XP95 Intrinsically Safe (IS) Detectors are a development of the well-established intelligent XP95 range of detectors. They
feature all the benefits of the standard range, but are developed specifically for use in hazardous areas. The XP95 IS detectors are
connected to the Delta Fire Detection System through Delta Apollo Detection and Alarm Modules (DA Apollo) available as separate DA’s or
as 2 loops or 4 loops SUB Panels.
Addressable XP95 IS detectors and addressable XP95 IS MCP’s is connected to the loop through Protocol Translators and Galvanic
Barriers (ref attached drawing). A total number of 4 pcs Protocol Translators/channels can be connected to each loop providing a total of 72
(18 pcs per spur) IS detectors per loop. The maximum spur capacitance is 70 nF.
For safe areas we recommend to use the IQ8 Quad Detector range together with Delta Quad Detection and Alarm Modules. The Delta
Quad DA Modules can be mixed with the Delta Apollo DA Modules on the same Delta Network.
Cost-effective Detection and Alarm Module for decentralised solutions. Communicate with
Apollo detectors and fully meets EN 54.2 requirements regarding fail-safe networks. The
Delta DA is operated via the Delta OP panel and is designed for hook-up to other Delta
DA modules. Delta DA is equipped with a communications output for direct hook-up (via a
LON-kit) to other Delta Units
Art. no. 251244.1
Features:
2 analogue Apollo loops
126 detectors per loop
3 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
1 eBus (LON-kit)
Approvals: Complies with EN54.2 and EN54.4
Features:
Art. no. 251072 2 analogue Apollo loops
126 detectors per loop
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
Features:
Art. no: 251073 4 analogue Apollo loops
126 detectors per loop
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
The XP95 IS Mounting Base has been designed to accept only IS products. This ensures
that standard detectors inadvertently be fitted into an intrinsically safe system.
Detector base for watertight installations applicable for the XP95 and Discovery detectors
range. To be used in machinery spaces and similar areas were there may be humid and
wet conditions.
Art. no. 235562
Art. no 235133
Galvanic Barrier
The Galvanic Barrier and Protocol Translator are installed in the safe area ensuring of
communication between control equipment and field devices and safety within the limits of
BASEEFA approval.
Art. No:
235131 (1 channel)
235132 (2 channels)
Protocol Translator
The Protocol Translator and Galvanic Barrierare installed in the safe area ensuring of
communication between control equipment and field devices and safety within the limits of
BASEEFA approval.
Art. No:
235138 (1 channel)
235139 (2 channels)
Alarm-bell: MBA6-BBX4
Diameter: 150 mm
IP rating: 55
Sound output: 100,1 dB(A)
Current consumption: 12mA
Acoustic alarm
Diameter: 92 mm
IP rating: 65*
Sound output: Based on the chosen 32 tones (87 - 111dB)
Voltage rating: 15 – 28VDC
Current consumption: 7 - 27mA
Art. no. 243120
Alarm circuits must have constant voltage
*For obtaining IP 65, sealed base must be used, article 235312
Asserta sounder
Available Q2 2011
Dimensions: 168 x 168 x 155mm
IP rating: 66
Sound output: 120dB
Voltage rating: 15 – 28VDC
Current consumption: 450mA
Sounder/Beacon Symphoni AV
Available Q2 2011
Dimensions: 110 x 110 x 100mm
IP rating: 66
Sound output: 100dB
Light output: >1Cd
Art. no. 243127 Voltage rating: 9 – 28VDC
Current consumption: 10mA
Beacon XL
Red light
10 joule
24V
Current consumption: 700mA
Alarm circuits must have constant voltage
Art. no. 251584
IP rating 65
Beacon
Red light
5 joule
IP rating: 55
Voltage rating: 20..28 VDC
Current consumption: 300mA
Art. no. 243118 Alarm circuits must have constant voltage
EX ALARM DEVICES
Data: Description: List price:
To be used on the on the alarm output when connecting Exia Alarm Devices
Limit switch
The Omron limit switch, 251615, is a limit switch for monitoring the closing of fire doors.
The unit has a resin roller mounted on a metallic lever. The length of the level is adjustable
Art. no. 251605 to simplify the installation. The unit has a conduit cap for installation of a cable gland. Cable
gland is not included.
Features:
2 analogue Apollo loops
Art. no. 251244.1 4 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
Features:
Art. no. 251072 2 analogue Apollo loops
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
The production cost of FireWin Presentation is dependent of the amount of devices. The
cost for a total FireWin Presentation is split in three; license, layout and per point.
Art. no. 234676.10
FireWin Presentation Layout
Workstation
Art no.: 251458 - Marine approved LCD monitors for recess mounting in bridge or control
consoles.
TFT - 17.0 or 19” inch
Optimal Resolution @ Hz:
1280 x 1024 @ 60 Hz
Power Supply:
24 VDC or 115/230 VAC
To be used when connecting PC or other external equipment to the Delta Modules via
RS232. The Galvanic Isolator is used to avoid earth fault when connection external units
to the Delta System and will also provide over voltage protection for both systems. Need
24 VDC supply voltage. 9 meter cable to be used between the fire alarm panel and the
Galvanic Isolator is included.
Art. no. 251029
MIMIC Panel
Customized mimic fire alarm panel, price on request based on customers specifications.
MANAGEMENT SOFTWARE
Data: Description: Notes:
FireWin Publisher
FireWin Publisher is application to be used together with Firewin Presentation and makes it
possible to publish alarm status on WEB. When an alarm or pre-alarm situation occurs, the
Firewin Publisher automatically distributes the alarm status to all PC’s in a network that
have Firewin Publisher installed.
Art. no:
251414 (SW Application)
251414.01 (Clients)
Delta Terminal
Eltek Fire & Safety’s Delta Terminal is a Windows application that can be installed on
laptops, PC’s or PDA.s and makes it possible to remotely control and operate Delta fire
Alarm Systems through Internet/intranet. This application gives you a unique possibility to
remotely monitor and control Delta Fire Alarm installation.
Art. no:
251504 (OPC Application)
251504.1 (100 addresses)
251404.2 (1000 addresses)
eNode
This communication unit is used for connecting other products such as a FireWin PC to the
Delta fire alarm systems. The eNode is also used as an interface unit for other fire alarm
modules connected to the multi-master eBus network, or if you need to connect the Delta
System Modules in a redundant network. In this case you connect the eNode to the RS232
port on the Delta DA’s. With this configuration the Delta DA’s will send the system
information both directly on the eBus and through the RS232 port. If one of the
Art. no. 235762
communication lines fails you will still have communication on the other.
Note: If you are connecting the eNode to a PC or laptop an RS232 cable has to be ordered
with reference to article#: 255750.006. If you are using eNode to connect the Delta System
in a redundant network you need to order a dedicated cable to be used between the eNode
and the Delta DA. Please refer to article#: 255750.010
This unit is based on a Delta OP but without display and keypad. Used as a communication
interface for voice alarm, SMS communication or as an interface between the Delta System
and other alarm devices. The Delta Communication IF is equipped with 7 digital inputs.
A fiber-optic modem for transmission of eBus data via optic fibers. The modem is
connected directly to the Delta Modules via eBus. External 24V DC supply voltage is
required. This allows the user to build either a bus- or redundant ring topology through
fibre. A distance of 5 km can be achieved by using Multi Mode fiber (standard version).
The transmission distance can be up to 24 km by using a Single Mode fiber (available on
request).
Art. no.
242671.060 multi mode
242671.065 single mode
This modem makes it possible for eBus communication between Delta Units through
Internet. The Delta System is connected to the TCP/IP Modem through a eNode (article#
235762)
ACCESSORIES
Data: Description: Notes:
The kit consists of a printed circuit board and a cable. When the kit is installed inside the
DELTA OP it enables an input from the PA system to mute the fire alarm system.
The kit consists of a printed circuit board, a cable and a relay. When the kit is installed
inside the DELTA OP it enables the PA system to mute the fire alarm system and the
BAMS system to mute the panel buzzer
To be fitted on the IQ8 QUAD addressable detector range for dust protection.
Packing unit: 50 pcs.
DETECTOR LABELS
Data: Description: Notes:
ELTEK programming hand held tool for setting addresses for the IQ8 / IQ8QUAD
detectors. The tool is recommended to be kept onboard for easy programming if a detector
is to be replaced.
The Tools 8000 is a PC application allowing you to configure and read status of the IQ8
Quad Detectors. The Tools 8000 can be used for a range of tasks, supporting the entire life
cycle of the system – from installation to regular preventive maintenance. The kit contains
the Tools 8000 application and a I/F to be used when connection the laptop or PC to a
single detector or a detector loop.
Art. No. 789860
The cable between the FireWin PC and the eNode. Galvanic isolator is included in the
cable. Cable length: 9 metre
Service Printer
To be connected to the RS232 com port on the Delta OP. Used for service and
commissioning purpose. Cable is not included and has to be ordered separately.
TEST EQUIPMENT
Data: Description: List price:
Test gas
Flame Detector Test Kit for 601 series IR Flame detectors. p/n
243019.100 and 243019.200
T110 Infra-Red Test Source with T110 Adaptor for 601F/801F Detector
The Flame Sensor Test Kit is a tool which is designed to test flame detectors without
the need of real flames.
Mimics the characteristics of real flames
Demo suitcase
Demo suitcase for demo purposes. Suitcase contains one Delta OP Marine, one DAQ, one
GA button, detectors, bases and manual call points. The system is programmed and ready
to use. The suitcase is used for demonstrating detectors, manual call points and GA button.
IQ8Quad detectors are programmed with sound, speech and GA sound.
The Eltek Fire and Safety brand is represented worldwide Engineers ready to travel on short notice to any regions of the
trough a network of highly skilled and authorized partners world. Service performed by authorized personnel mean that
providing systems sales, system design, commissioning, service quality is maintained year after year and guarantees that repairs
and after sales support to ship owners and ship yards. On-site and service is performed in accordance with manufactures
service is also provided by a dedicated team of Field Service specifications.
2011/03 – 1000x / Zoom grafisk AS – Subject to change without notice - ©2011 Honeywell International Inc.