1. MSP-16-Exp Overview
MSP-16-Exp board is designed to collect the calls coming from landings for the systems which have 16 floors or less. Also,
they are designed for the control of call leds, displays (Direction, floor number information). The landing calls are controlled
in MSP-16-Exp board up to 16 floors with single button, and up to 9 floors with double button. It is used in systems with
ARCUBE panel by connecting to LCB control card.
General
Dimensions
Width × Length × Height (mm) 165 x 79× 32 (All female terminals are plugged in)
Operating temperature 0 - 60 °C
Weight 182 gr.
Electrical Characteristics
Supply voltage Via LCB
0,984W (Standby)
Power consumption
2,95W (Max. power consumption)
Gray/Inverted
Gray/Binary/Inverted Binary Max.100 mA output current for each at 24V
(M0, M1, M2, M3)