Elevator overtravels when same time and the elevator is not at the highest level
03
going upwards In upward operation, the upper limit disconnected
Door fails to open in position after the door-open signal outputs for
consecutive 15 seconds (except the absence of door-lock signal), reports
failure for 3 times
05 Door lock will not open Short circuit for lobby door lock: the elevator is in the hall area. Lobby door
lock signal exists without car door lock and with door-open limit signal (for
consecutive 1.5 seconds) (only effective for car door separation under
high-voltage input)
Door fails to close in position after the door-close signal outputs for
consecutive 15 seconds (except the existence of door-lock signal) and
Inconsistence
reports failure for
for 84times
seconds between door-close limit and door lock
06
Door lock will not close determines time-out for door close (except the existence of door-lock
signal). Failure reported after 8 inconsistences
Communications interference
28 Sensor failure for lower The sensor for lower leveling floor is not in action
leveling floor Failure 28 reported, when the action on the sensor for lower leveling floor is
greater than the maximum effective protection distance or greater than the
maximum invalid protection distance
When the length of the leveling spile is less than 300mm: maximum
protection distance for effective action = 300mm*4
When the length of the leveling spile is greater than 300mm: maximum
protection distance for effective action = length of the leveling spile*4
When the top floor is less than 3: maximum protection for invalid action
= maximum story height*1.5
When the top floor is greater than 3: maximum protection for invalid action
= maximum story height*2.5
Leveling position error is too Test the leveling position error at stop. Failure report when the error detected
30
large is greater than the value set by F146.
Door- lock close signal input when the door-open limit signal is in action
37 Door-lock failure When door-lock relay detection is set, the lock input point has
inconsistent high and low voltage detection
The control part of the AIO sends out run signal, but does not receive the run
40 Run signal failure
signal feedback from the drive part
Overtravel in upward movement and the lower level forces slow open/close,
42 Deceleration switching error or overtravel in downward movement and the upper level forces slow
open/close
When the door opens, the hall door lock has inconsistent pressure detection
54 Inconsistent lock failure
point with the door lock
In operation, the output contactor contact is detected disconnected, turn off
60 Base closure failure
the output of the AIO and report Failure 60
After the brake is opened, no zero servo terminal signal is received returning
61 Signal start failure
from the drive part
After start, the elevator maintains the speed at 0, and the elevator does not
62 No speed output
move
The combination of the length of 1) The leveling spile is too long or too short. Algorithm: (length of the
the self study leveling spile and leveling spile + leveling switch space) / 2 less than 100mm or greater
the distance with the leveling than 900mm.
68
switch does not meet the 2) The leveling area is too long or too short. Algorithm: (length of the
requirements leveling spile - leveling switch space) / 2 less than 10mm or greater
than 100mm