DESIGN OF BASE PLATE

𝑓_𝑦 = 250 MPa 〖𝑓′〗 _𝑐 = 20.7 Mpa


𝑃 = 1029.86 kN footing size = 1m x 1m

𝐴_1 =
𝑃/(0.7 〖𝑓′〗
_𝑐 )
𝐴_1 〖𝑚𝑚〗 ^2
71073.84
=
𝐴_2 (1000)(1000)
=
𝐴_2 〖𝑚𝑚〗 ^2
1000000
=
𝐹_𝑃 = 0.35 〖𝑓′〗 _𝑐
√(𝐴_2/𝐴_1 )

𝑃/𝐴_1 = 0.35 〖𝑓′〗 _𝑐


√(𝐴_2/𝐴_1 )

𝐴_1 = 20206〖𝑚𝑚〗 ^2

Use 𝐴_1= 71073.84


〖𝑚𝑚〗 ^2
𝐹_𝑃 = 0.35 〖𝑓′〗 _𝑐
√(𝐴_2/𝐴_1 )

𝐹_𝑃 = 27.18 Mpa 0.7 〖𝑓′〗 _𝑐


>

= 〖𝑓′〗 _𝑐
Use 𝐹_𝑃 0.7
𝐹_𝑃 = 14.49 MPa

Size of the Square Base Plate


𝑃/𝐵^2 = 𝐹_𝑝

2000000/𝐵^2 = 14.49

B = 266.60 say 270

Use 270 x 270 square base plate

Thickness of Base Plate


𝑡 = 2𝑛√(𝑓_𝑝/𝐹_𝑦 )

𝑓_𝑝 = 𝑃/𝐴

𝑓_𝑝 = 136650/(270)^2
𝑓_𝑝 = 136650/(270)^2

𝑓_𝑝 = 1.87 MPa < 14.49 MPa


𝑡 = 2(67.5)√(1.87/250)

𝑡 = 11.69 mm say 12 mm

Use t = 12 mm
A36 STEEL, Fy = 250 MPa
1029860 N CHANGE FOOTING SIZE IF NOT

14.49

CHANGE FOOTING SIZE IF NOT 1MX1M


B= 1000
D= 1000

7.245
142147.68806

20205965221
20205.965221

CHECK IF WHAT A1 TO USE


14.069873575
3.7509830145
27.17587194

USE LOWEST VALUE Fp

CHANGE P AND Fp
71073.84403
266.59678173
CHANGE SAY

CHANGE USE

136.65 kN
p= 136650
72900
1.8744855967
CHECK IF < 14.49 MPa
USE LOWEST Fp
CHANGE n AND Fp
n= 67.5 135
CHANGE FOOTING SIZE IF NOT 1MX1M

F NOT 1MX1M

USE LARGER VALUE


0.007498
0.086591

Das könnte Ihnen auch gefallen