Kultur Dokumente
570 ?
2- For pipe exceeding 10’’ in diameter, a test point is an area defined by circle of diameter not greater
than
1. 1’’. 3. 2.5’’ (API 570-3.1.20)
2. 2’’. 4. 3’’
3- An NPS 8 pipe operates at maximum of 675 psi and temperature ----700° F--- ASTM A106 GB
material. What allowable stress should be used to determine the thickness?
4- In the guided bend test used to qualify WPS , crack occur on specimen are acceptable:
1. Only if they are not associated with the test weld. (ASME IX-QW-163)
2. Under no circumstances.
3. If there is no evidence that they were due to slag inclusion.
4. If the transverse opening is not larger than 1/8’’.
5- Which of the following is not an acceptable temporary repair for 12’’ steel pipe with localized
corrosion?
6- A piping system has a design pressure of 500 psig and design temperature 482°C what is the
minimum acceptable flange class if the flange material ASTM A105 ?
1. Class 300. 3. Class 600. By material group and pressure and tempreture B16.5
2. Class 400. 4. Class 900.
7- The maximum depth of undercut allowed for a girth weld made in normal service for 13mm
thickness
1. No visible undercut. (B31.3-Table 341.3.2)
2. 1/32’’ (1mm).
3. 1/16’’(1.5mm).
4. 1/8’’(3mm).
8- The maximum surface temperature for dry magnetic particle testing of weld:
1. Set by the manufacturer of the examination medium. (ASME V T-731-c)
2. 250°F.
3. Limited by the permeability of the magnetic particle.
4. 600°F.
10-Which of the following is the maximum allowable working pressure conditions of 380 psig at
700°F° ,the material is A53 Grade B ,thickness is 0.28’’ corrosion rate is 0.005 inch per year from
now?
1. 337 psig. Missing data are Diameter, Next planed inspection
2. 380psig. MAWP=2St/OD ,
3. 390psig. t= measured thickness-2corrosion Rate *next interval inspection
4. 400psig.
NPS 10, OD:10 ¾’’ , A106 GB, allowable stress :20000psi, weld efficiency :E =1,
thickness :0.3’’(from inspection) , corrosion rate :0.02 inch per year
Next planned inspection : 5 years MAWP=2St/OD
13-Threaded carbon steel piping in an NPS 1 ½’’ piping system in normal service replaced. What is the
minimum pipe schedule to be used? ( B31,3-Table 314.2.1)
1. Schedule 40.
2. Schedule 60.
3. Schedule 80.
4. Schedule 160.
14-The density of the step wedge comparison films and densitometer calibration comparison with a
calibrated step wedge film traceable to:
1. An ASME code, Section V certified film. (ASME V-T-262.1)
2. An ASNT certified step wedge.
3. An ASNT certified procedure.
4. A national standard.
15-Which inspection method is suitable for locating corrosion cell, galvanic coating problems,
underground contacts, and areas of low pipe to soil potential:
1. Soil resistivity testing. (API 574- 10.10.1.2)
2. close-interval potential surveys.
3. Particle examination.
4. pipe coating Holiday survey.
16-When reviewing a group of radiographs, all of the following information must be available except.
1. Minimum source to film distance. (ASME V- T-292)
2. Geometric unsharpness.
3. Material type.
4. Exposure technique.
17-Which of the following may be assumed in computation made when calculating maximum
allowable working pressure for unknown material?
1. Highest grade material. (API 570- 7.2)
2. Average grade material.
3. Carbon steel material.
4. Lowest grade material.
18-A piping system made of mixed grades of piping including A-53 carbon steel with silicon killed
elbows and fittings, has recently been rerated from 400°Fto 500°F.the processes fluid contains
0.52% weight sulphur. The unit inspector should :
1. Increase number of TML on the system .
2. Continue monitoring the system utilizing existing TML if they have 0.002inch per year
Corrosion rates.
3. Relocate the TML to the fittings.
4. Not be concerned with the 100°F change.
19- What is the minimum required of thickness (tm)(including corrosion allowance)NPS 4 inch if it
operates at 525psi at 400°F ,material is API 5L A25 ERW and C.A 0.0625 inch
1. 0.099 inch.
2. 0.147 inch.
3. 0,150inch.
4. 0.161inch.
20-A buried piping designed for 100 psi (0.689MPa)service is hydrostatically tested 125PSI(0.861MPa)
for 8 hours, after 4 hours the pressure has dropped 5psig and pumped back up to 125psig
(0.861MPa) .during the remaining 4 hours the pressure drops by 5psi (0.03MPa) ,according to
instructions in API standard 570 the inspector should
21-Piping system is designed for 300 psig, at 700°F the allowable stress value at test 20,000 psig .The
allowable stress value at design temperature is 15,000 psig . which is pneumatic test pressure?
1. 330 psig.
2. 440 psig.
3. 450 psig.
4. 600 psig.
22-What is the maximum BRINELL hardness number allowed when welding pipe using P6 material?
1. BHN 200. (B31.3- Table 331.1.1)
2. BHN 225.
3. BHN 241.
4. Hardness testing is not required for this material.
23-In general, the corrosion resistance of iron and nickel alloys in sulfidation atmospheric is depend
upon the content of :
1. Molybdenum. (API 571- 5.1.1.5.6)
2. Chromium. (API 571- 4.4.2.6)
3. Nickel.
4. Niobium or Titanium.
24-Reheating of hardened metal to a temperature below the transformation range improve toughness
is known
1. Stress relieving. (B31.3-300.2-h)
2. Tempering.
3. Annealing.
4. Normalizing.
25-Which of the following is the standard height of the raised face section of class 400 raised Face
flange:
1. 0.060 inch(2mm).
2. 0.100 inch(2.5mm).
3. 0.125 inch(3mm).
4. 0.250 inch(7mm).
28-The rate of corrosion under insulation will usually not increased by insulation system that:
1. Contain chloride salts.
2. Do not utilize vapour barrier.
3. Wick moisture.
4. Are made of closed-cell foam glass.
29-When cracking is suspected and an internal visual inspection reveals no indication of cracks which
of the following testing method is not recommended by API RP 574 to use as spot crack check?
1. MT.
2. PT.
3. UT.
4. RT.
30-Plate material can be used only for which of the following flanges?
1. Class 150.
2. Threaded.
3. Blind.
4. Class 150 and Class 300 up to NPS ½.
31-An inspection reveals that a repaired NPS 4 seamless pipe ,A53 Gr B, has the thickness of .180
inch.if service is 1000psig at 500°F, what is the actual remaining corrosion allowance) , considering
only internal pressure?
1. 0.043 inch.
2. 0.064 inch.
3. 0.070 inch.
4. 0.116 inch.
32-When unexpected movement of piping system is observed, what should the inspector do to
evaluate the problem?
1. Increase the frequency of inspection.
2. Check the piping stress analysis. (API 570- 7.5)
3. Develop an inspection plan.
4. Discuss these observations with a piping engineer.
33-An ASTM A 106 Gr B NPS 10 pipe with a wall thickness of 1.125 inch must have a section replaced
what preheat is recommended?
1. None.
2. 50°F. (B31.3- Table 330.1.1)
3. 175°F.
4. 200°F.
1. 1/16 inch
2. 1/8 inch
3. 5/32 inch
4. 3/16 inch
37-Chloride stress corrosion crack of 300 series SS generally occur above about:
5. 100°F (38°C).
6. 140°F (60°C). (API 571-4.5.1.3-g)
7. 180°F (82°C).
8. 212°F (100°C).
39-With respect to piping systems for which service condition have been changed if data for the same
or similar service are not available, a corrosion rate for a piping circuit is estimated from the
experience of the owner/operator or from:
1. Published data on piping systems in comparable service.
2. The highest known corrosion rate on the unit. (API570- 7.1.2-b)
3. ‘’worst case’’ industry data.
4. A default corrosion rate of 10 mils per year (0.01 inch per year).
2. 0.80 inch.
3. 0.875 inch.
4. 1.000 inch.
42-An NPS 12 carbon steel standard wall pipe in (class2) ,pressure 450 psig (3.1 MPa) and 500°F with an
allowable stress 20,000 psi at inspection of 0.28 inch .what is the maximum interval for the next
thickness measurement inspection if no RBI analysis has been performed ? E =1, corrosion rate
0.025inch per year.
1. 2.7 years. (half the remaining life or Acc to table2 whichever less)
2. 3.0 years.
3. 5.0 years.
4. 5.5 years.
44-Subject to specific approval of the inspector, welding procedures qualified by others may be used
provided that all of several conditions are met. One of this condition is that :
1. The employer has made only slight changes to the WPS.
2. The employer has not made any change in the welding procedure.
3. The base material P number is either 1, 3, 4 GR # 1 or 8and impact testing is required .
4. The material to be welded is not more than 1 inch thick and requires PWHT.
45-During inspection for CUI ,an insulated austenitic stainless steel class 1 piping system operating at
300°F would require what percentage of following –up examination at areas with damage
insulation?
1. 0 %.
2. 25 %.
3. 50 %.
4. 75 %
46-The number of TML required on high-temperature hydrocarbon lines containing sulphur corrosives
are often fewer than on other corrosive system because the Sulfur lines (API 570- 5.6.3)
1. Exhibit very uniform corrosion independent of location in the system.
2. Are not considered to be a potential environment risk.
3. Corrode at such a fast rate that they are considered consumable and are rep----
predetermined time schedules.
4. Are constructed of high –alloy materials that are unlikely to erode.