Sie sind auf Seite 1von 200

Smoke extraction

Smoke Exhaust Fans


▲ roof-installation
▲ wall-installation
▲ central ventilation fans

Aktionsgemeinschaft Entrauchung

TLT-Turbo GmbH
TLT-TURBO GMBH
STANDARD FAN PRODUCTION PLANT AT
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
BAD HERSFELD 002
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

TLT standard fan production plant at Bad Hersfeld

Our Bad Hersfeld facility has a histo- blished in June 1995, now integrating
ry going back to 1874, when Benno Babcock-BSH’s Air and Thermal En-
Schilde and August Büttner founded gineering division.
their factories here.
The “TLT-Turbo GmbH”, newly esta-
The “exhausters” traditionally made blished in March 2003 as a company
of cast iron could be built much lighter in their own rights, belongs to AG
and cheaper through the use of steel Kühnle, Kopp & Kausch, Frankenthal.
sheet.
TLT now is one of the world’s leading
At Büttner the focus was initially on fan manufacturers and our compe-
blowers for tubular boilers and dryers, tence is expressed in mature and
then shifted to heavy-duty industrial very economical products. Our two
fans as required specifically in power R&D centres at Zweibrücken and Bad
plant de-dusting applications. Schil- Hersfeld guarantee a continuing pro-
de, meanwhile, stepped up its rese- cess of always adapting all TLT pro-
arch and development of light-duty ducts to the latest demands of the
ventilating fans and medium-duty in- market.
dustrial blowers. Numerous patents
and registered designs testify to a
steady flow of engineering breakth-
roughs. With the erection of its series
production facility at Bad Hersfeld,
dedicated mainly to the cost-effective
production of roof fans, the Babcock-
BSH Group gained a leading market
position both in Germany and abroad.
The Turbo-Lufttechnik GmbH (TLT) –
Bad Hersfeld site - was newly esta-

All technical details in this catalogue are subject to modification without prior notice.
SMOKE EXHAUST FANS
FOR ROOF- OR WALL-INSTALLATION OR AS
CENTRAL VENTILATION FANS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany INDEX 003
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Product-Range – Overview 004 – 007


Basics, Test-report issued by Munich Technical University/Approval by DIBt, Berlin
Application examples 008 – 038
Roof-mounted
Centrifugal Smoke Exhaust Fans BVD Main Dimensions 041
400/620°C – 120 min. Characteristic Curves /Technical Data 042 – 044
Specification texts 045 – 046

Axial Smoke Exhaust Fans BVAXO


Dimensions and Weight 048 – 050
200/300°C – 120 min.
Acoustic Data 051
Technical Lists 052 – 053
Characteristic Curves /Technical Data 054 – 058
Specification texts 059 – 060
Axial Smoke Exhaust Fans BVAXN 12/56
Dimensions and Weight 061 – 063
200/300/400°C – 120 min. Acoustic and Thermal Isulation 065 – 067
Acoustic Data 068
Technical Lists 069 – 077
Characteristic Curves /Technical Data 078 – 087
Specification texts 088 – 093
Axial Smoke Exhaust Fans BVAXN 8/56
600°C – 120 min. Dimensions and Weight 095 – 097
Acoustic Data 098
Technical Lists 099 – 100
Characteristic Curves /Technical Data 101 – 107
Specification texts 108 – 110
Two-Stage Axial Smoke Exhaust Fans BVZAXN 12/56
Dimensions and Weight 113 – 115
200/300/400°C – 120 min.
Technical Lists 116 – 118
Characteristic Curves /Technical Data 119 – 126
Specification texts 127 – 128
Wall-mounted Axial Smoke Exhaust Fans BWAXO
Dimensions and Weight 130
200/300°C – 120 min.
Specification texts 131 – 132
Wall-mounted Axial Smoke Exhaust Fans BWAXN 12/56
Dimensions and Weight 133
200/300/400°C – 120 min.
Specification texts 134 – 136
Centrifugal Smoke Exhaust Fans BVW
600°C – 120 min. Dimensions and Weight 138 – 150
Characteristic Curves /Technical Data 151 – 154
Specification texts 155 – 160

Centrifugal Smoke Exhaust Fans BV-REH


Dimensions and Weight 162 – 166
400°C – 120 min.
Acoustic data 169
Characteristic Curves /Technical Data 170 – 172
Specification texts 173 – 174
Centrifugal Smoke Exhaust Fans BVRA
Dimensions and Weight 175 – 179
620°C – 90 min. Characteristic Curves 180 – 184
Specification texts 184 – 186
Subject to modification.

Centrifugal Plug-In Smoke Exhaust Fans BV-ERV Product Range - Overview and
300°C – 120 min. Main Dimensions 187

Smoke detection switches for mechanical smoke extraction 189 – 196


Application examples / References 200 – 201
RANGE – OVERVIEW
SMOKE (FUME) EXHAUST FANS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 004


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Centrifugal Smoke Exhaust


Fans, roof-mounting type /
Series BVD
for use in fume and smoke
extraction applications.
Temperature / Time category
according to EN 12101 – Part 3
F 400 400°C – 120 min
F 600 620°C – 120 min
6 sizes: 315 - 710

Centrifugal Smoke Exhaust


Fans, roof-mounting type
Series BVW-D for extracting
fumes and smoke from unheated
indoor areas (e.g., cold warehou-
se buildings), with snow safety
rating, snow load class SL 1000.
Temperature / Time category
according to EN 12101 – Part 3
F 600 600°C – 120 Min
6 sizes: 315-710
RANGE – OVERVIEW
SMOKE (FUME) EXHAUST FANS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 005


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Axial Smoke Exhaust Fans


Series BVAXO for use in fume
and smoke extraction applications.
Temperature / Time category
according to EN 12101 – Part 3
F 200 200°C – 120 min
F 300 300°C – 120 min
6 sizes: 400 - 1120
Installation within the fire zone is
possible (without additional
cooling).

Axial Smoke Exhaust Fans


Series BVAXN 12/56 for use in
fume and smoke extraction
applications.
Temperature / Time category
according to EN 12101 – Part 3
F 200 200°C – 120 min
F 300 300°C – 120 min
F 400 400°C – 120 min
14 sizes: 355-1600
Installation within the fire zone is
possible (without additional cooling).

Axial Smoke Exhaust Fans


Series BVAXN 8/56 for use in
fume and smoke extraction
applications.
Temperature / Time category
according to EN 12101 – Part 3
F 600 600°C – 120 min
10 sizes: 500-1600
Motor cooling is provided by a
cooling fan. Installation within the
fire zone is possible (with custo-
mer-supplied cooling system).
RANGE – OVERVIEW
SMOKE (FUME) EXHAUST FANS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 006


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Centrifugal Smoke Exhaust Fans,


wall mounting type
Series BVW-A (fitted externally on
the building wall) for use in fume
and smoke extraction applications.
Temperature / Time category
according to EN 12101 – Part 3
F 600 600°C – 120 min
6 sizes: 315-710
Motor cooling with outdoor
ambient air.

Centrifugal Smoke Exhaust Fans,


wall mounting type
Series BVW-R (installed in the
room containing the fire source)for
use in fume and smoke extraction
applications.
Temperature / Time category
according to EN 12101 – Part 3
F 600 600°C – 120 min
6 sizes: 315-710
Motor cooling with outdoor ambient
air via an auxiliary cooling duct.

Axial Smoke Exhaust Fans, wall-


mounting type
Series BWAXO To be mounted in
an outer wall for fume and smoke
extraction (no additional cooling
required).
Temperature / Time category
according to EN 12101 – Part 3
F 200 200°C – 120 min
F 300 300°C – 120 min
Sizes: 400/500/630/800

Axial Smoke Exhaust Fans, wall


mounting type
Series BWAXN 12 / 56
To be mounted in an outer wall for
fume and smoke extraction (no addi-
tional cooling required).
Temperature / Time category
according to EN 12101 – Part 3
F 200 200°C – 120 min
F 300 300°C – 120 min
F 400 400°C – 120 min
Sizes: 400/500/630/800
RANGE – OVERVIEW
SMOKE (FUME) EXHAUST FANS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 007


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Centrifugal Smoke Exhaust Fans


for central service
Series BVW-R/B with inlet duct,
for installation within the fire zone
(floor-mounted).
Temperature / Time category
according to EN 12101 – Part 3
F 600 600°C – 120 min
Motor cooling with outdoor ambient
air via an auxiliary air duct or addi-
tional cooling fan.
6 sizes: 315-710

Centrifugal Smoke Exhaust Fans


for central service
Series BVW-A/B with inlet duct,
for installation in a ventilated room,
possibly with customer-supplied
insulation (floor-mounted).
Temperature / Time category
according to EN 12101 – Part 3
F 600 600°C – 120 min
6 sizes 315-710

Centrifugal Smoke Exhaust Fans


for central service
Series BV-REH for use in fume
and smoke extraction applications.
Temperature / Time category
according to EN 12101 – Part 3
F 400 400°C – 120 min
Fans also available with thermal
and acoustic insulation.
12 sizes: 400-1400

Centrifugal Smoke Exhaust Fans


for central service
Series BVRA for use in fume and
smoke extraction applications.
Temperature / Time category
according to EN 18232 – Part 6
F 600 620°C – 90 min
Fans also available with thermo-
insulated casing for installation in a
ventilated room.
19 sizes: 180-1400
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 008


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

3.0 Basic considerations 4.0 History of TLT smoke technik GmbH of Bad Hersfeld sup-
exhaust fans plies a complete range of smoke and
Some recent fires have reminded fume exhaust fans for virtually any
us of the vast potential for destruc- In the early '70s, a fire in a PVC film application. Needless to say, each
tion, injury and loss of life that fire manufacturing shop devastated the model is fully tested and certified ac-
may have. Its perils lie in the blaze production facilities of Kalle AG in cording to the latest European stan-
that forms the core of the disaster Wiesbaden, a leading manufacturer dards and regulations. And it all be-
and in its products such as smoke of packaging film. Presumably, an gan with that "small fire” at Kalle AG
and heat, both of which are at their overheated bearing had ignited a in Wiesbaden.
most hazardous form in a "capti- small quantity of PVC and caused a
ve" state, i.e., within an enclosed local smouldering fire that neverthe-
building. Practical experience has less released clouds of billowing smo-
shown that the smoke is much mo- ke. The damage was assessed at se-
re dangerous to human beings veral millions DM.
than the heat (flames). According
to fire statistics, two-thirds of all The high loss was caused by the hy-
deaths due to fire result from suf- drochloric acid vapours which inevita-
focation and smoke poisoning, bly form in the combustion of PVC.
while one-third is caused by burns These gases attacked all unprotected
and collapsing buildings. These metal surfaces of the film making line,
observations confirm the domi- which had to be scrapped as a result.
nant role of smoke as a threat to Kalle's works fire department contac-
human beings in the event of a fire. ted the Hersfeld-based BSH com-
Moreover, hot smoke and combu- pany, their traditional fan supplier,
stion gases, in conjunction with and requested the development of a
thermal buoyancy effects, may lite- fan that would be able to extract smo-
rally "pre-heat" those building ke, fumes and toxic matter via the
areas to which the flames themsel- roof. Starting out from their standard
ves have not yet spread, thus pa- roof fan range, BSH (now TLT) set
ving the ground for their propaga- out to develop a roof-mounted smoke
tion. exhaust fan rated for "higher tempe-
ratures". Following extensive in-hou-
These conditions and hazards impo- se testing, the unit was finally classi-
se a whole set of requirements for an fied for 400°C service for a duration of
effective preventive fire protection 120 minutes.
strategy. The main objectives can be
summarized thus: Thus, the "smoke exhaust fan" was
born, although a market warranting
• Smoke extraction volume production or even promising
• Smoke dilution significant sales revenue had yet to
• Keeping escape routes and be identified. At the time, stationary
smoke exhaust fans were virtually un-
rescue accessways clear
known as a preventive fire protection
of smoke so as to facilitate solution. Through word of mouth in
the fire-fighting effort. the fire-fighting and consulting ex-
perts' community and an intense in-
To prevent the fire from spreading, formation and sales promotion effort
the heat of combustion must be re- directed by BSH at fire authorities,
moved from the building along with building supervision offices, archi-
the smoke. In modern building servi- tects and specifiers, the potential of
ces engineering, mechanical smoke smoke/fume exhaust fans was soon
and heat exhaust systems have the- established. In addition to the roof-
refore become a standard feature sin- mounted fan versions, the market
ce they effectively protect lives and soon demanded diverse other desi-
property. The heart of such a smoke gns since smoke and fumes cannot
and heat exhaust system are the always be extracted via the building
smoke exhaust fans. roof. Thus, BSH began to develop
smoke exhaust fans for wall installati-
on and floor-mounted units for use in-
side buildings. Today, Turbo-Luft-
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 009


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

5.0 Legal basis However, each LBO code applies to "Structures shall be designed
all construction activities and equip- such that the outbreak of fire and
Although in Germany the conference ment. It is supplemented by building the propagation of flames and
of the Ministers of Urban Planning, law standards for classified construc- smoke are effectively prevented,
Housing and Construction (ARGE- tion materials, components, and spe- and that human beings and ani-
BAU) has imposed a model building cial components. mals can be rescued and an effec-
code (MBO) for reference by the fe- tive fire-fighting effort can be laun-
deral states, building law has in es- ched should a fire nevertheless oc-
A review of the building codes for the
sence remained the responsibility of cur."
various federal states with regard to
the latter.
fume and smoke extraction reveals a
As a result, applicable building law is common principle that features in all
enshrined in the State Building Code German building regulations. Refer-
(LBO) of each federal state. It follows ring to smoke and heat control, sec- Considering this being a general for-
that fire protection requirements vary tion 17(1) contains the following pro- mulation, the aim of the efforts can be
regionally. vision: seen clearly though.

Laws, regulations and codes

ARGEBAU Model building code - MBO


(Conference of Ministers)

Individual state building code - LBO

Buildings of special types and uses Technical rules


(section 51 MBO) (section 37 et seq. MBO)

Administrative regulations and guidelines Technical Guidelines


Sales Premises Guideline Fire behaviour
Homes DIN 4102
Garages Ordinance Fire protection of buildings
Building Services Testing Ordinance Interior furnishings
Hospitals Ordinance DIN 18230
Highrise Buildings Ordinance Smoke and heat extraction systems
Construction Materials Guidelines DIN 18232
Public Assembly Facilities Ordinance Fire detection systems
Industrial Construction Guideline DIN 14675
etc.

Supplementary guidelines and acknowledged rules of engineering practice Building rules list

VDS VDE VDI VDMA Reqirements on


construction materials

MRA CE, ÜZ
EN 12101-3 testing
DIBt approvals
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 010


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

5.1 Objectives in preventive


fire protection
Fire Protection Objectives
The rather general provisions of
section 17 at least serve to define Active rescue Passive rescue Ventilation Fire
the overriding objective. measures measures of the fire localization
This is to maximize the hazard pre-
vention effort so as to achieve a ma-
ximum degree of fire safety. In global
terms, this goal implies the following: Live saving Environmental Property protection
objective: objective: objective:
• Restriction of flame propagation Keep escape routes Minimize use of Preverve the
free of smoke fire-fighting media building structure
• Securing the rescue of human
beings and animals
• Ensuring the feasibility of fire- Reduce Minimize Support the Preserve
fighting activities environmental fire-fighting fire-fighting escape/rescue
damage damage effort routes
Given the interrelationship between
construction, building services and
equipment technology, it emerges
that the steps aimed at achieving the-
se goals cannot be viewed in isolation German Criminal Code relating to en- This leads us to the question of how
but must always be judged and as- vironmental offences stipulates the these rules are defined, and where
sessed in the common context. Smo- following: they are published. By studying trade
ke and heat control, which will always "Any person engaged in the planning, publications and corporate informati-
form an integral part of any overall management or execution of a buil- on material and by attending profes-
building protection strategy, is no ex- ding construction activity who violates sional congresses and symposiums,
ception to this rule. generally accepted rules of practice, the individual specialist should be ab-
thereby endangering the life or health le to maintain an up-to-date under-
of another, shall be punished with up standing of current practices.
to five years' imprisonment, or impo- At least, in the event of a loss invol-
5.2 Personal liability
sition of a fine." ving human injury, such familiarity
In the period since 1994, nearly all It follows that planners, experts and with the "state of the art" will be his
German states have amended their other professionals, apart from being best defence.
building codes in an effort to simplify aware of the standards and guideli-
and accelerate the construction pro- nes described in section 3.3, should
cess. The aim was to reduce the make a continuous effort to remain on
amount of regulatory intervention and top of the "accepted rules of practice".
to strengthen the responsibility of the
building/project owner. In essence,
preventive inspection and testing re-
quirements are limited to a small
number of building or structural crite-
ria. Wherever the building authorities
have thus shed their original respon-
sibilities, liability now rests with the
building owner. As a result, owners
will usually have to enlist expert aid
(architects, consultants) to have the
building inspected on their behalf for
compliance with all material aspects
of the building code.
Not many building professionals such
as architects, planners and experts
are aware of the resulting responsibi-
lity and indeed, personal liability, they
assume through the exercise of their
profession. Thus, section 323 of the
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 011


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

5.3 Standards and guidelines


List of German and European standards for smoke and heat
Design guidelines for mechanical extraction systems
smoke exhaust systems are defined
in the European standard EN 12101- German standards
DIN 18232 Structural fire protection; smoke and heat control
5 (draft) and the German DIN 18232, DIN 18232 Teil 1, (draft) Terms, safety objectives
part 5 (pre-standard). DIN 18232 Teil 2, (draft) Natural smoke and heat exhaust ventilators,
requirements, design, installation
As a rule, the design and sizing pro- DIN 18232 Teil 3, (draft) Natural smoke and heat exhaust ventilators,
cess should be coordinated with the testing
relevant authorities (fire safety experts, DIN 18232 Teil 4, (draft) Heat exhaust systems
DIN 18232 Teil 5, Mechanical smoke exhaust systems,
fire safety authority, local fire depart- (preliminary standard) requirements, sizing
ment, building supervision office, etc.) Release of an EN standard is not to be expected
from the earliest planning stage. in the near future.
DIN 18232 Teil 6, Vornorm Mechanical smoke exhaust systems,
Fire loads shall be determined in ac- (preliminary standard) testing
DIN 18232 Teil 7, Smoke exhaust systems for staircases (in preparation)
cordance with DIN 18230, parts 1 and 2. (working paper)
Other sizing methods are possible
where they are justified, e.g., in the European standards
case of EN 12101 Smoke and heat control systems
EN 12101-1, (draft) Specification for smoke curtains; requirements and test methods
- different heat release modes EN 12101-2, (draft) Specification for natural smoke and heat exhaust ventilators
EN 12101-3, (draft) Specification for mechanical smoke and heat exhaust ventilators
- use of suitable computing methods EN 12101-4, (draft) Natural and mechanical smoke and heat exhaust systems,
for determining smoke gas mass flows installation and test methods
EN 12101-5, (draft) Design and calculation methods for smoke and heat exhaust
- issuance of particular specifications systems
EN 12101-6, (currently Design,calculation methods and installation procedures for
by a fire protection expert under revision) pressure differential systems for room flow control monitoring
- special conditions, e.g., special types
of building use

6.0 Fundamentals

6.1 Initiation of fire

The outbreak of a fire and its subse-


quent propagation are contingent on
the presence of

• an inflammable substance

• an ignition source of sufficient energy

• oxygen

6.2 Propagation

The evolution of a fire is essentially


determined by the composition of the
inflammable substance, the supply
and concentration of oxygen, and the
resulting combustion temperature.
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 012


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.3 Smoke formation and beha-


viour Smoke
Smoke and
and temperature development
temperature development
The combustion process releases lar- without smoke and heatextraction
without smoke and heat extraction
ge amounts of combustion gases
(oxides), smoke and thermal energy

d
°C
e
which will accumulate under the cei-

pe
fir

50

e o
ling of the building, spreading both

(5

fir vel
th

er
horizontally and vertically from there.

de
of

ov
n

lly
The key function of a smoke and heat

sh
io

Fu
at

a
exhaust system is to remove smoke

Fl
in
ig
from the building. Depending on the
nature of the fire source, the smoke Or
may be more or less toxic. The room
in which a fire has started may fill with
enormous volumes of smoke in just a
Temperature
few minutes.
Smoke

Time

The following phases can be obser- 3. Flash-over (eruption of a sudden


ved: blaze in the fire area
1. Ignition phase 4. Fully developed fire
2. Smouldering fire 5. Subsequent cooling phase

6.3.1 Smoke propagation example


in case of fire
A staircase with a floor area of 16 m2
and a height of 15 m can be filled with
smoke and products of combustion
more than 100 times over by the me- without...
re burning of 10 kg of foam rubber.
The fire releases heat, combustion
gases, and smoke. In a fully enclosed
indoor space these will rise to the cei-
ling due to thermal buoyancy effects.
The resulting layer of smoke and
combustion gases originally gathered
there will increase in density until it
fills the entire room. At the same time,
the environment heats up quickly due with smoke exhaust fan t
to the high energy release rate. When
a temperature of 550 ºC is exceeded, Propagation of smoke in the case of fire
flash-over occurs, i.e., a sudden bla-
ze erupts throughout the heat-affec-
ted area.
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 013


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.4 Operating principle of mecha- nings. If these openings are adequa- chanical smoke exhaust equipment.
nical smoke and heat exhaust sy- tely sized for the dimensions and Fig. 2 illustrates this state. If one ta-
stems combustible content of the room, the kes into account all relevant planning
Depending on the nature of the bur- evacuation of hot smoke and the in- aspects, natural and mechanical
ning substance, varying degrees of gress of fresh air will be ensured. Ide- smoke exhaust systems emerge not
smoke formation (density) may be an- ally, as the fire progresses, the gas as competing solutions but as sepa-
ticipated. Originating in a small area, cushion under the ceiling should re- rate strategies complementing each
these gases eventually rise to the cei- main at a constant height above floor other effectively. Apart from the buil-
ling where they will form a smoke lay- level (equilibrium condition bet- ding situation, the expected thermal
er which initially does not mix with the ween inflowing air and extracted conditions in the event of a fire are a
cold air underneath. As the fire gains smoke), so that enough visibility and key consideration.
force, more and more combustion breathing air remains available un-
gas accumulates under the ceiling of derneath for human beings to leave
the closed room. Eventually the gas the room and to conduct fire-fighting
cushion expands downwardly, to- operations. This equilibrium can be
wards the floor. Once it has fallen to achieved via simple openings toward
below head level, the prospects for the outside, as well as through me-
rescuing people and controlling the fi-
re become critical.
When the room containing the fire is
opened at specific (planned) points,
the thermal and smoke load is redu-
ced by the resulting inrush of air and
the simultaneous extraction of smo-
ke. Initially, a pressure equalization
with the surrounding ambient areas
takes place. With time, an underpres-
sure forms in the lower half of the Smoke cushion
room and more fresh air enters
through the appropriate access ope-
Unobstructed visability

Air supply Air supply

Equilibrium state between air supply and extraction of smoke

The smoke exhaust fan is the heart of any mechanical smoke and heat exhaust system
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 014


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.4.1 Difference between natural • Windowless rooms, or areas located Disadvantage:


and mechanical smoke/heat deep inside the building structure • Electrical installation requirements.
extraction systems • Roof and building designs rendering Advantage:
Natural smoke and heat extraction natural exhaust systems ineffective
systems rely on the thermal beha- due to wind attack conditions. • The full air power is available as
viour of gases. They use the so-called soon as the fan is activated or trig-
• Rooms in which high temperatures gered. The goal of keeping escape
"chimney effect", i.e., the draft crea- cannot form due to combustible
ted between the air supply and ex- routes smoke-free is effectively
content, combustion behaviour, si- achieved, specifically in the impor-
haust levels due to the density diffe- ze, or the presence of automatic fire-
rence between the cooler fresh air tant early stages of the fire.
fighting installations (e.g. sprinklers)
and the hot combustion gases. • The volume flow remains nearly
• Cleanrooms in which the opening of constant throughout the duration of
Advantage: a supply/extraction vent for testing the fire.
• Increasing volume flow as the fire or maintenance purposes would al-
progresses. ready create an operating disruption.
Disadvantage:
• Limited effect in the case of a low
temperature and height difference
between the supply/exhaust ope-
nings.
• Building characteristics and unfore-
2

seeable influences of wind limit the maschinelle


mechanical smoke/
effectiveness of natural smoke/heat · MRA
heat extraction
m
extraction systems. m· 300°C
Mechanical smoke/heat extraction thermische
natural smoke/
heat extraction
systems utilize fans designed speci- NRA
fically for hot smoke and combustion 1
gas duty.
These fans can be adapted to the in-
dividual building situation and extrac-
tion requirements by design.
Mechanical smoke/heat extraction
systems would be preferred in the fol- 0
0 20 300 600 °C 900
lowing cases where a natural system (T-273) ➞
is either not feasible or would imply
an unreasonable degree of complexity:
Mass flow comparison between natural and mechanical smoke/heat extraction systems

According to DIN 18232, a basic distinction is made between the following:

 Natural smoke extraction systems (rooms subject to fire hazard) NRA


 Mechanical smoke extraction systems (rooms subject to fire hazard) MRA
 Pressure-based fire protection systems (stairwells, corridors) RDA
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 015


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.5 Smoke exhaust fans The approval certificates of the Buil- Key requirements under section
ding Supervisory Authority, issued by 45(1) of the Building Products Act re-
The relevant requirements are defi- the German Institute of Building late to the following properties:
ned by the European product stan- Technology, a corporation under pub- • mechanical strength
dard DIN EN 12101, Part 3 ("Smoke lic law, acknowledge compliance with • stability
and heat control systems – Specifica- the technical requirements of the Buil- • fire protection
tion for mechanical smoke and heat ding Rules List B2. • hygiene
exhaust ventilators"). All TLT smoke
• health
exhaust fans are tested to this stan- This document is published by the
• environmental protection
dard and meet its severe require- German Institute of Building Techno-
• safety for use
ments. logy (Deutsches Institut für Bautech-
• acoustic insulation
nik, DIBt).
In addition, German building law re- • energy savings
quires each fan to be generally ap- The Building Rules List "B", Part 2, in- • thermal insulation
proved by the Building Supervisory cludes construction products which The essential requirements are detai-
Authority. are sold and introduced into commer- led in the basic documents under Ar-
ce under regulations governing the ticle 12 of the Council Directive
In accordance with this requirement, our
implementation of European Commu- 89/106/EEC of December 12, 1988.
smoke exhaust fans possess the sup-
nity directives, with the exception of
plementary General Building Supervi-
regulations for the implementation of
sory Approval issued by the German In-
the Construction Products Direc-
stitute of Building Technology (DIBt),
tive,where such directives do not re-
Berlin. Significant advances in standar-
flect key requirements of section 5(1)
dization of preventive fire protection
of the German Construction Products
technology have allowed these stan-
Act and additional proof of suitability
dards to be integrated into building law.
for use is required under German Building Rules List "B",
With the inclusion of smoke exhaust
building codes to meet these require- Edition 97/1 (Excerpt)
fans into the Building Rules List, their in-
ments. Such construction products The Building Rules List "B" is a
stallation has become permissible only
must bear the DE label in addition to compilation of construction pro-
where the relevant units are tested and
a conformity label according to the ducts whose introduction into com-
certified to legally valid standards.
building codes of the German federal merce and sale is subject to regu-
6.5.1 Suitability testing and certifi- states. The specific requirements of lations of European Union member
cation by the Building Super- section 5(1) of the Construction Pro- states – including Germany – and
visory Authority ducts Act not met by the directives of signatory states of the Agree-
are stated in column 4 of the Con- ment on a European Economic
Only one test institute in Germany is struction Rules List "B", Part 2. Co-
accredited to perform suitability Area, and which bear the CE label.
lumns 5 and 6 indicate which suitabi- For smoke exhaust fans, the Buil-
testing of smoke exhaust fans accor- lity and conformity certificates a pro-
ding to the test and inspection provi- ding Rules List "B", Part 2, shall be
duct must possess to fulfill such key applicable.
sions of EN 12101-3. This is the test requirements of the German state
institute of the Technical University of building codes.
Munich (Domestic Services Re-
search Laboratory).

All TLT smoke exhaust fans possess


Supervisory Approval issued by
Deutsches Institut für Bautechnik in
Berlin.
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 016


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.5.2 Various installation configurations


The diverse available models, designs and types cover the needs of virtually any application.

Fan installation outside the fire


compartment and outside the buil-
ding
These fans need no thermal insulati-
on. The minimum distance to combu-
stible materials must be met. (Belt-
driven fans must, however, be fitted
with heat insulation).
smoke layer
Rauchschicht

Fan installation outside the fire


compartment but inside the buil-
ding (in an adequately ventilated
room)
The fan must be insulated in accor-
dance with DIN 4102-4, or enclosed
in mineral fibre lagging (density ⭌ 90
smoke layer
Rauchschicht kg/m3) measuring at least 40 mm in
thickness.
wall
Wand F 90
F90

Fan installation inside the fire com-


partment
If the fan is suitable for installation
within the fire compartment, no insu-
lation is necessary.
(Fans depending on external air for
cooling must be provided with an ap-
propriate L90-grade cooling air supp-
smoke layer
Rauchschicht ly duct. However, this requirement is
not applicable to wall-mounted fans).
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 017


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Complete test rig for roof-mounted smoke exhaust fans. Fumes are Heat-insulated repair switch, cooling air inlet nozzle
extracted from a furnace and returned to it via a duct connected to the
fan outlet.

6.5.3 Test conditions and criteria refore been our policy to test them on for which TLT smoke exhaust fans
a voluntary basis in conjunction with are built.
Our smoke exhaust fans are functio-
the fan system. For each fan series, a
nally tested under virtually realistic
minimum of two (up to a total of five)
mounting conditions. Each fan series
specimens had to be tested depen-
is run in smoke extraction mode ac-
ding on type and model. The number
cording to its appropriate temperatu-
of specimens reflects the criteria set
re/time category for at least the speci-
forth in the test standard as well as
fied minimum operating duration; in
the diversity of application conditions
most cases, the test is continued for
much longer (Table 1).
6.5.4 Suitability testing criteria
• Volume flow decrease over the test Temperature / Time Category according to EN 12101, Part 3
interval () 10%)
Category F300 F200 F400 F600 F842 not assigned
• Reduction in static pressure head
over the test interval () 20%) Temperature (¡ C)
as determined
• Surface temperature increase on in- according to 300 200 400 600 842 by supplier
sulated fans must not exceed 180 K EN 12101-T3
at any one point Insulated fans
as determined
minimum operating 60 120 120 60 —
by supplier
6.5.5 Tests duration (min)

The prescribed tests relate to smoke Tested operating dura-


120 120 120 120 —
exhaust fans operating as standalone tion of TLT fans (min)
units in an installed condition.
In determining categories, existing classifications under national standards
Many accessories, although not sub- such as DIN, BS, etc., were taken into account.
ject to testing themselves, are critical
for the operation of the fan. It has the- Table 1
SMOKE (FUME) EXHAUST FANS
TECHN. UNIV. OF MUNICH CONSULTANCY REPORTS
GENERAL APPROVALS UNDER BUILDING
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany SUPERVISORY LAW 018
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.5.6 Supervisory Approvals and Test Reports

Fan type Fan series Temperature Minimum Report General


limit operation duration No. approval
[°C] [min.] No.

Roof-mounting fans BVD (SDI) 620 120 96/1162 Z-78.1-24


BVD (SDI) 400 120 97/1188 Z-78.1-25
BVW-D 600 120 96/1166 Z-78.1-29

Wall-mounting fans BVW 600 120 96/1166 Z-78.1-29


BWAXO 200/300 120 98/1196-1 Z-78.1-41
BWAXN 12/56 200 120 96/1167-4 Z-78.1-18
BWAXN 12/56 300 120 96/1167-2 Z-78.1-20
BWAXN 12/56 400 120 96/1167-6 Z-78.1-21

Central service fans BVRA * 620 90 91/196-1-a* Z-78.1-16


Centrifugal fans BVW for 600 120 98/1196-3 Z-78.1-29
floor installation
BV-REH 400 120 98/1196-4 Z-78.1-42
BV-ERV 300 120 98/1196-2 Z-78.1-43
Axial-flow fans BVAXO 300 120 98/1196-1 Z-78.1-41
BVAXN 12/56 200 120 96/1167-4 Z-78.1-18
BVAXN 12/56 300 120 96/1167-2 Z-78.1-20
BVAXN 12/56 400 120 96/1167-6 Z-78.1-21
BVAXN 8/56 600 120 96/1167-1 Z-78.1-17

Accessories Inlet box for BVW types 96/1166 Z-78.1-29


Outlet dampers for BVW types 96/1166 Z-78.1-29
Automatic shutoff dampers 2140**
Flexible connectors 2140**
(inlet or outlet side)
Bases for BVD + BVW-D Z-78.1-24
Z-78.1-25
Round silencer TSR 2140**
Noise-damping base SDS 2140**

* to DIN 18232-6 ** Expertise regarding use for preventive fire protection


SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 019


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

6.5.7 Fan sizing The air flow rate through the supply – installation room cooling
openings should be ) 3 m/s.
As a rule, any smoke and heat ex- – thermal installation
haust system must be sized in con- 5. Determine the total pressure loss
formance with applicable laws and across the system. – use of tested and approved acces-
standards. This can only be accom- 6. Select the appropriate fan sories (e.g., flexible connectors,
plished through cooperation between spring-type antivibration mounts, si-
the specifier and the building supervi- Often it may appear expedient to use lencers, shutoff dampers)
sory authority. As a result, the calcu- the fan for normal room ventilation
lation steps and sizing criteria outli- purposes as well. In this case, a drive – uninterruptible power supply
ned below should only be viewed as a motor with two or three operating
guide. speeds may be selected. The lower
rpm level is then used for normal ven-
ting, while the higher speed is activa-
Sizing steps ted in the event of a fire.

1. Calculate the fire load of the room


in question and the theoretical fire Fan use
load with the aid of the formulas gi-
ven above (from DIN 18230, Part Selecting the right fan in terms of tem-
1, and the design specifications of perature resistance, operating time
EN 12101-5 or EN 18232-5). and output does not suffice to ensure
a proper smoke exhaust system. The
2. Determine the requisite smoke ex- following fan operating aspects must
haust volume flow. likewise be taken into account:
3. Determine the smoke temperature. • The switchgear cabinet for the smo-
If the temperature thus obtained ke exhaust fan must be installed
exceeds the proof temperature of outside the rooms exposed to a fire
the fan the number of air changes (or high temperature) hazard.
must be increased, or a bypass
Switchgear cabinets or panels must
must be installed to mix the extrac-
not be fitted on an (interior or exterior)
ted smoke with cooler air.
wall of the fire compartment.
4. Determine the leakage air flow and
Only the fulfilment of these aspects,
the requisite total air volume.
which are all too often neglected in
The leakage flow will vary as a func- the use of smoke exhaust fans, can
tion of pressure loss conditions and ensure an effective smoke and heat
number and sizes of ducts in the sys- exhaust operation in conjunction with
tem. In practice, long duct sections on the correct fan sizing.
the fan inlet side and the associated
high pressure loss will often translate Please also see our Installation,
into leakage flows that exert a signifi- Operating and Maintenance In-
cant impact on the overall system structions.
throughput.
Smoke exhaust fans may be opera-
It should always be remembered ted via a frequency converter when in
that the exhaust volume flow of a normal venting mode, but not in smo-
mechanical smoke exhaust sys- ke extraction service (except where
tem is measured not at the fan, but the frequency converter is tested in
in the assumed fire compartment conjunction with the fan).
under normal conditions.
To ensure a reliable smoke extraction
The anticipated leakage loss must be performance the installation must
taken into account in any fan sizing conform to the fan manufacturer's
effort. specifications and to all requirements
In this context the specifier should al- imposed by the Building Supervisory
so check whether the air supply ope- Authority, e.g., with regard to
nings are sufficient for the total make-
up air volume, and whether appro-
priate scavenging conditions exist in
the room.
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 020


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

7.0 Fire load determination The theoretical fire compartment area distribution as well as the combustion
according to DIN 18230, A expressed in m2 will therefore not behaviour of the inflammable sub-
Parts 1 & 2 always be the same as the surface stances. Obviously, the mass of un-
area of a smoke compartement of a protected paper, cardboard, textile
A method of determining the fire load building to be assessed. In practice material, etc., that will be consumed
and its relevant factors is defined in one room or flights of rooms having a by fire in unit time is much larger than
DIN 18230, Parts 1 & 2. According to smaller surface area than the fire the corresponding mass of wood or
this standard, the fire load q (in compartment concerned will depend packaged products.
kWh/m2) is the aggregate amount of on the demands of the mechanical
heat that can be released by all com- smoke extraction. For our purpose we Depending on the material and its net
bustible materials in a given fire zone must calculate the room surface area calorific value and storage density,
having a theoretical surface area A (in to be protected by the mechanical the combustion factor mi will typically
m2). This can be written as follows: smoke extraction system. vary between 0,2 and 1,7.

q = ⌺ (Mi · Hui) in kWh/m2


In any event, each area in the affec-
ted fire compartment must be asses- For more detailed information, refe-
A sed in terms of the quality and quanti- rence should be made to DIN 18230,
The term "combustible materials", as ty of combustibles it contains, i.e., we Part 1, Addendum 1.
used here, must be deemed to inclu- must determine the mass Mi (in kg) of
de all inflammable substances, each combustible substance and its
whether building materials, operating net calorific value Hui (in kWh/kg).
fuels and consumables, stored pro-
ducts, packaging, or surface finishes The result is the fire load for the fire
(e.g., paneling, coatings or the like). compartment area AR examined.
More detailed instructions are pre-
sented in the standard m.a. ⌺ (Mi · Hui)R
q’ = in kWh/m2
AR
DIN 18230 and the resulting equation
are intended for determining the re- The calculated fire load qr for unpro-
quisite fire resistance time of the buil- tected combustibles is obtained after
ding components in a specific fire weighting with the combustion factor mi.
compartment. As a result, applicati-
ons of the standard may deviate from ⌺ (Mi · Hui · mi)R
qr = in kWh/m2
those discussed in the present docu- AR
ment.
The calculated fire load used in de-
While the parameters and asses- sign should be at least equal to 25
sment methods defined in the stan- kWh/m2.
dard relate to a theoretical building
section ("compartment") affected by The combustion factor mi is thus di-
fire, in the present case individual rectly reflected in the design of the
analyses for specific rooms or groups smoke/heat exhaust system. It re-
of rooms must often be conducted. flects the specific type, shape and
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 021


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Excerpt from the Addendum to DIN Extract from annex to DIN 18230 - part 1
18230, Part 1. For details refer to DIN 18230, part 1 + part 2, preliminary standard
(More detailed data are given in DIN Compact- mi-
18230, Parts 1 & 2) No. Material
ness % factor
1 Wood and wooden materials
spruce wood
boards
squared timber 40 mm x 40 mm
squared timber 100 mm x 100 mm
squared timber 200 mm x 200 mm

spar, scalped diameter 150-300 mm


loose wood wool (pressed bale)

chipboard (DIN 4102 - B 2)


2 Paper, cardboard
writing paper and printing paper
rolles or sizes of cardboard on paletts
painted cardboard

unpainted cardboard

bales of wrapping paper

paper rolls, standing, lying or on pallets


cut to size
painted paper
unpainted paper
sanitary crepe paper rolls, or packed in bags
3 Textile products
cotton
fibre bales
pressed fibre bales
pressed polyamide fibre bales
Pressed polyacrylenitrile bales
fibres, not modified
fibres, modified with approx. 35% vinyledenchloride
waste
pressed cotton, polyamide and polyacrilnetrile
fibres bales
q = fire load in kWh/m2 4 Plastics
q’ = fire load in kWh/m2, related to polyethylene
the fire department granulate in individual sacks
moulded parts (empty beer boxes) piled up
qr = calculated fire load in kWh/m2 polystyrole
hard foam (DIN 4102 - B 3) PS 20
AR = Surface of the fire compartment hard foam (DIN 4102 - B 1) PS 20 SE
in m2 polyurethane hard foam
PUR hard foam (DIN 4102 - B 2)
Mi = mass of the individual combu- PUR hard foam (DIN 4102 - B 1)
stible material in kg Polycarbodiimide hard foam
UP unsaturated polyester resins , glass-reinforced
Hui = net calorific value of the bars in loose piles
individual combustible material 5 Solid fuel
in kWh/kg brown-coal briquettes, dropped charge
mi = combustion factor of the indivi- 6 Combustible liquids in bath-tube combustion

dual combustible material chlorbenzole


cyclohexane
w = heat exhaust factor dimethylformamide
glycole
c = conversion factor in min. oil fuel EL
m2/kWh oil fuel S
iopropylealcohol
tä = equivalent fire duration in min. methanole
l = cubic capacity of the room in m3 oleoresin
xylene
tm = average fire room temperature *) bulk density = material volume / total volume or = bulk density / apparent density
in °C
**) incineration factors mi < 0.2 can be evaluated according to DIN 18230 part 1, if the
n = air changes in h–1 examination authority issued their comments according to advice and recommendations
(number per minute) given in NABau-Arbeitsausschuss XII 45/2 ”m-factor”
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 022


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

7.1 System design in As soon as the fire brigade has arri- A note in the standard tells us that the
accordance with ved at the scene, it will take charge of presence of a sprinkler system justi-
DIN 18232, Part 5 rescue operations and can also de- fies the selection of the next lower di-
termine whether or not the mechani- mensioning category. This statement
The new standard DIN 18232, part 5, cal smoke exhaust system should re- must be viewed as exceedingly pro-
applies to large rooms with a mini- main in operation. The time between blematic. A discharge of water from
mum interior height of 3 m. However, the start of the initiation of the fire and the sprinkler system into the accumu-
it is not suitable for rooms with statio- the arrival of the fire brigade is there- lated smoke layer will definitely in-
nary gas extinguishing equipment, fore decisive. Where a company fire crease the amount of smoke to be ex-
storage rooms with storage heights department is in place, an interval of tracted. In addition, the water literally
exceeding 1.5 m, hazardous material 5 minutes is typically assumed. With forces the smoke downwards into the
storage areas, and hazardous duty volunteer fire brigades and under un- escape routes, which should be kept
rooms. usually adverse conditions, as much clear by all means.
The calculation of the volume flow to as 20 minutes may pass. In the nor-
be extracted is based on the so-called mal case, calculations will be based
on an average fire development time Our recommendation, therefore, is
dimensioning category. To obtain the
of 10 minutes. to leave the mechanical smoke ex-
appropriate dimensioning category it
haust system running for as long
is necessary to determine the under- Once this interval has been defined in as occupant protection is still an
lying fire development time and the fi- consultation with the expert and/or lo- issue, and to ensure that the
re propagation rate. The fire develop- cal fire department, the fire propagati- sprinkler system will be triggered
ment time is the interval between the on rate remains to be determined. It after the smoke exhaust fans.
outbreak of the fire and the start of fi- depends on the combustible materi-
re-fighting operations. In any case, it als present in the various fire com- Moreover, the standard assumes
is assumed that the premises are pro- partments. smoke compartment surface areas in
tected by a fire alarm system in ac- the region of ) 1600 m2.
Combustible construction materials in
cordance with EDIN VDE 0832-2 The volume flow of smoke to be ex-
non-combustible packaging, for in-
(VDE 0833T2) with fire detectors as tracted and the fan temperature cate-
stance, have a particularly low fire
per DIN EN 54-7, or else that appro- gory can now be determined from the
propagation rate. On the other hand,
priately trained personnel is conti- exhaust flow rate tables, depending
where substances such as benzene
nuously present. The mechanical on the desired depth of the low-smo-
or rubberized products are stored, the
smoke exhaust system should be trig- ke layer, the dimensioning group, and
flames will spread very quickly.
gered by smoke detectors as soon as the energy release rate (a result of
Usually, an average propagation rate
possible,as only this way the evacua- the fire load calculation).
will be assumed.
tion of occupants, who are mostly un-
familiar with the building, can be en-
sured.

Fire Brigade

fire- departure of
message fire brigade

outbreak of fire

arrival of fire brigade at scene

= fire developement time to be used


SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 023


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

The pre-standard DIN 18232-5 gives


tables for two different fire scenarios:
The energy release rate to be em-
ployed as a function of the calculated
fire load is 600 kW/m2 in one case
and 300 kW/m2in the other.
The "installation rules" likewise provi-
ded in the standard shall be exami-
ned in detail in section 7.5.
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 024


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

7.2 Design according to DIN 18230 events. Bearing this in mind, and in 7.3 Necessary number of air
and Quenzel accordance with a calculated equiva- changes
lent fire duration and the assumption
For guidance, Fig. 7 plots the curve of An attempt is made in Fig 8 (page
that no fire-fighting action is taken,
the unit-temperature in the fire com- 025) to give a guidance to the neces-
the unit-temperature curve permits an
partment over time. A few key critical sary number of air changes as a func-
approximate calculation of the tem-
temperatures have been marked in tion of the fire room height and pre-
perature increase (or fire temperatu-
the diagram as average points of oc- vailing fire load. It is assumed that the
re) to be expected . A real-case ana-
currence of the events identified. smoke concentration (kj2) in the room
lysis of fire loads and building situati-
is kept below 25% for 15 minutes af-
For the smoke exhaust system desi- ons yields an equivalent fire duration
ter the smoke exhaust system is ac-
gner the question arises in this con- of 20 – 55 minutes for most buildings,
tivated.
text which temperatures (and specifi- so that smoke temperatures of about
cally, which combustion gas tempera- 1020 to 1220 K (750 - 950°C) would This 15-minute interval was selected
ture) must be expected in case of a fi- have to be anticipated from the fire since it will normally give enough time
re. compartment. to evacuate occupants and initiate fi-
re-fighting measures.
A clear-cut law linking from the fire The temperature in the fire compart-
compartment temperature to the fire Smoke development is an important
ment will not reach this level if a smo-
load cannot be established because factor here since it has a major impact
ke and heat exhaust system genera-
of the diversity of effects governing on visibility in the room.
tes sufficient air changes from the
each individual fire. However, we can start.
identify a relationship between the fi-
re load and the equivalent fire durati- In this case the average fire tempera-
on tä, a term introduced in DIN ture should be described by the em-
18230. The equation incorporates the pirical formula:
factors w and c:
qr
tä = c · qr · w in min tm = 20 + 250 log (4 · t2ä · ) in °C
n·l

The heat factor w is a coefficient ex-


pressing the specific ventilation con- This formular including the number of
ditions characterizing the fire scena- air-changes.
rio. Depending on the arrangement of
the smoke extraction system and the This temperature is approximately
make-up air supply (and possibly, the equal to that of the extracted air, and
achievable number of air changes), a may therefore be used to determine
value of w = 2.2 to 3.2 may be assu- the temperature resistance of the me-
med for a mechanical smoke exhaust chanical smoke exhaust system.
installation.
The conversion factor c, according to tä = equivalent fire duration (in min)
DIN 18230, reflects the thermal insu-
lation properties of the fire compart- tm = average fire room temperature
ment enclosure walls. It is given as c (in C°)
= 0.15 to 0.25 min. m2/kWh, the hig-
her value indicating the higher insula- qr = calculated fire load (in kWh/m2)
tion level. n = air changes (number per hour)
If the insulating capability of enclosu-
l = cubic capacity of the room (in m3)
re components is destroyed by the fi-
re, e.g., because of windows shatte-
ring, a value of c = 0.15 may be
adopted.
Where this computing method is ta-
ken into account in the system design
process, it should be remembered
that the various factors all have an
uncertainty margin to the positive or
negative side. Still, they should be
used as a guide in calculating fire
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 025


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Beispiel
Example
940 Melting point of some stones

Melting point of aluminium


Melting point of glass, softening point of steel
Ignition point of wood
Critical temperature for steel-reinforced concrete
Temperature in fire zone tBA in °C

Fracture point of multilayer glass

Fracture of normal glass windows


Melting and flash point of rubber and plastic

65
Duration of fire tä in minutes

Fig. 7: Temperatur criteria during evolution of fire


Number of air changes per hour

Beispiel
Example
15

Cubic capacity of the room in m3 720


Fig. 8: Number of air changes required, as a function of the fire load and room size, to maintain
ki2 = 25% for 15 minutes after activation of the smoke and heat exhaust system.
SMOKE (FUME) EXHAUST FANS
SIZING - APPLICATION EXAMPLE 1
CENTRIFUGAL SMOKE EXHAUST FAN FOR 600°C SERVICE
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany SERIES BVW-R WITH INLET DUCT 026
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

8.4.8 Example 1 From: DIN 18230, Table 1 qr


Mi (kg) Hui kWh
tm = 20 + 250 log (4 · tä2 · ) in °C
Material kg
mi Mi · Hui · mi (kWh) n·l

Bibliography: Dipl.-Ing. Karl-Heinz Wood 5600 4,8 1 26880


Textiles 3000 4,3 0,4 5160 In our example,
Quenzel, „Smoke and Heat Extrac- Plastics 672 6,7 0,4 1800 141
tm = 20 + 250 log (4 · 622 · ) = 595,65 °C
tion Systems“, 2nd edition TOTAL 33840
15 · 720

At 596°C, it does not exceed the


A furniture warehouse in a multi-sto- By dividing this sum through the floor 600°C operating temperature of the
rey building is to be protected. Fig. 10 area of 240 m2, we obtain smoke exhaust fan.
shows the floor plan and elevation, as qr = 33840 = 141 kWh
2 Ad 4. A leakage air flow presumably
well as the fan arrangement. 240 m
Ad 2. Taking into account the room does not have to be taken into
volume of 720 m3 the resulting account, since the ducts are
The floor plan geometry and arrange- requisite number of air changes routed inside the storage room
ment of the air supply opening (door) per hour is 15 (N=15). Please re- only. The volume flow to be ex-
permit a good transverse ventilation fer to fig. 8. tracted can thus be written as
of the room with just a short fan zu 3. V = n · l =
connecting duct. A concentrated sup- Ad 3. Using qr, the equivalent fire du-
15 h–1 · 720 m3 = 10800 m3/h
ply of make-up air, combined with an ration tä can now be calculated.
underpressure in the warehouse, For this purpose we assume Ad 5. The resistance of the duct sy-
keep the corridor and the fire-fighting min · m2 stem, including protection
access zone clear of smoke. zu 3. c = 0,2 kWh grids, is about 400 Pa at a volu-
for the convertion factor, and w = 2.2 me flow of 10800m3/h (3 m3/s).
(from DIN 18230) for the heat ex- The pressure loss due to the
Sizing steps:
haust factor. It follows that cap is about 70 Pa, that of the
inlet box about 60 Pa. A fan de-
Ad 1. The room is assumed to con- zu 3. tä = c · w · qr = livering a total pressure increa-
tain a mix of stored materials in 0,2 · 2,2 · 141 = 62,04 min. se of approx. 530 Pa must the-
the following composition: 5600 refore be selected.
From this figure, a fire zone tempera-
kg wood, 3000 kg textiles, 672
ture of 940°C is obtained (see Fig. 7, Ad 6. A look at the characteristic cur-
kg plastics.
page 019). The average fire zone ve (page 153) suggests that a
temperature with the smoke exhaust centrifugal-type BVW-R 630/
The calculated fire load can thus be system in operation is determined via 25-6 smoke exhaust fan with in-
determined as follows: the following empirical equation: let duct would be a suitable unit.

Centrifugal-type smoke exhaust fan BVW 630/25


BVW-R 630/25-6 with inlet duct (intake box) 2000
Pressure losses
––– inlet duct
- - - BVW-D-damper
1800
626 725 1500 rpm
....... BVW-A or.
D damper

1600

= 1,2 kg/m3
452/1252

500 t = 20°C
1400

1200

1000
516

-4

800
1000 rpm
additional available pressure ⌬pt Pa 씮

600
-6
610
425

750 rpm
400

-8
200

710
500
725 626
5000 10000 15000 20000 25000 30000 35000

Fig. 9 Volume flow V m3/h 씮


SMOKE EXHAUST FANS
APPLICATION EXAMPLE 1
CENTRIFUGAL SMOKE EXHAUST FAN FOR 600°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany BVW-R SERIES WITH INLET DUCT 027
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Example 1
For planning and installation
Furniture warehouse in a multi-storey
please also refer to our
building, equipped with a wall-mounted Installation, Operation and
centrifugal smoke exhaust fan. Maintenance Instruction (MBW).
for 600°C – 120 minutes

Smoke
outlet
Make-up air inlet (wall opening) A

Storage area

10 m
– – – – – Fire-fighting access zone
– · – · – · Power supply and Control panel outside
control lines the fire compartment

Corridor area = Escape route


Door admitting B
make-up air Switch location

24 m

Scale 1:150

Flexible connector, Smoke exhaust duct, tested to


Outer wall temperature resistant 600°C–120 minutes (e.g. steel)
3m

Centrifugal smoke exhaust fan


BVW-R series with
inlet duct

Section A–B Scale 1:75

Fig. 10 Floor plan and sectional view of a storage room = Customer supplied
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 2
ROOF-MOUNTED SMOKE EXHAUST FAN FOR 400/620°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany BVD SERIES 028
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Example 2
Industrial shed ventilation and smoke
exhaust system using 3 roof-mounted
smoke exhaust fans.
400/620°C – 120 minutes

Make-up air
inlets (wall openings)
A

10 m
Control panel
Corridor area = Escape route
Door admitting
make-up air Switch location
B

25 m
Scale 1:150
Smoke outlet

Roof-mounted smoke exhaust fan


BVD series

Shutoff damper Tested roof-mounted base


(alternatively: concrete base)
3m

Make-up air inlet (wall opening)


Make-up air inlet (wall opening)
with smoke exhaust damper

Section A–B Scale 1:75


Fig. 11
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 3
WALL-MOUNTED AXIAL FLOW SMOKE EXHAUST FAN FOR 200/300/400°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany BWAXN 12/56 SERIES 029
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Example 3
For planning and installation
Industrial shed ventilation and smoke
please also refer to our
exhaust system using wall-mounted Installation, Operation and
axial flow exhaust fans Maintenance Instruction (MBW).
for 200/300 ar 400°C – 120 minutes

Door admitting make-up air


A Smoke outlet

10 m
Storage shed

Corridor = Escape route Smoke exhaust duct


Door admitting make-up air L90 (rectangular)
Switch location

B
25 m
Smoke outlet

Scale 1:150

Smoke L90 duct


3,5 m

Smoke
outlet
outlet

Wall-mounted axial flow exhaust fans


BWAXN 12/56 series

Section A–B Scale 1:75

Fig. 12
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 4
AXIAL FLOW SMOKE EXHAUST FAN FOR 200/300/400°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany BVAXN 12/56 SERIES 030
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Example 4
For planning and installation
Ventilation and smoke exhaust system
please also refer to our
using one axial smoke exhaust fan for Installation, Operation and
200/300 oder 400°C – 120 minutes Maintenance Instruction (MBW).

Smoke
outlet
A

E90

10 m
Storage area

Door
admitting
Corridor = Escape route
make-up area Switch location B

25 m

Scale 1:150

Flexible connector,
Smoke exhaust duct, tested to
temperature-resistant
400°C – 120 minutes (e.g. steel)
3m

Smoke
outlet Axial smoke exhaust fan
(non-insulated, installed in fire compartment)

Scale 1:75
Section A–B
Fig. 13 Customer supplied
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 5
AXIAL FLOW SMOKE EXHAUST FAN FOR 600°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany SERIES BVAXN 8/56 031
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Example 5 No cooling air fan required.


For planning and installation
Multi-storey building with basement
please also refer to our
ventilation and smoke exhaust system Installation, Operation and
using a BVAXN 8/56 series axial smo- Maintenance Instruction (MBW).
ke exhaust fan
for 600°C – 120 minutes

Alternative arrangement of the axial


smoke exhaust fan (fully galvanized type).

Fire-resistant smoke exhaust duct, L90

3,5 m
L90

Make-up
air inlet Axial smoke exhaust fan

3,5 m
(wall BVAXN 8/56 series
opening) Fan and flexible connector insulated by customer,
or fitted in separate (ventilated) room
(note motor cooling air requirement!)

Flexible
3,5 m

connector Smoke exhaust duct

Make-up air inlet (wall opening) near floor level.

Fig. 14
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 032


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

7.5 Installation notes for smoke maintenance specifications of DIN and its direction of impeller rotation
exhaust fans 4102, Part 12. must be verified.
By embracing intelligent solutions In practice, this means that the The circuit integrity, safety and relia-
at the planning stage and adopting connecting cables must not contact bility of the power supply must like-
a practice-oriented installation the fan casing and must be routed in wise be ensured. The system must be
strategy for the smoke exhaust appropriate mechanical protection maintained in good repair at all times.
systems. Its power supply must be ensured
system, users can save significant
The specifications further describe throughout the smoke extraction ope-
installation and maintenance ration. The option is essentially bet-
costs. the installation of switchgear compo-
nents and maintenance switches, ween a primary or secondary power
We are all familiar with practical ex- which must be provided in duly pro- supply. Secondary power may be de-
amples of fans virtually inaccessible tected form in areas not exposed to a rived from an emergency power unit
for maintenance, or whose disassem- fire or temperature hazard and in any or a second mains connection; in any
bly requires an unreasonable effort case, outside the fire compartment. case, it must be fully isolated from the
and can therefore be carried out only primary power source. The change-
on legal holidays – with the associa- As an example, consider the place- over between primary and secondary
ted penalty of immense cost. ment of maintenance switches outsi- supply must be automatic (second
de the fire zone. According to VDE mains connection). The power requi-
0113-1, such switches must be fitted rement of a smoke exhaust system
in the immediate vicinity of the fan for shall be rated under normal ambient
maintenance and repair purposes, conditions.
but this requirement applies only if the
fan is not in the line of sight of an ope- Another issue, ultimately, is the main-
rator at the switchgear cabinet. tenance of smoke exhaust fans. It
must be consistent with the fan ma-
It should also be noted that the fan's nufacturer's maintenance instruc-
radiant heat output must not interfere tions. As a minimum, component ope-
with maintenance switch operability, rability checks must be carried out at
and that the switch must be secured three-month intervals.
against unauthorized operation in its
energized state. (In no case shall If due regard has been paid to acces-
switches be mounted in the fire zone sibility at the planning stage, the follo-
without protection). wing functional checks can be perfor-
Installation example: BVAXN 8/56/1400 MD med quickly and economically:
Always remember when designing
circuits and control systems that the • Fan start-up test
Compliance with legal requirements fan's smoke extraction function must • Check of measuring and triggering
and the use of appropriate practical take priority over all other functions devices, smoke detectors and ma-
know-how constitute effective safe- the smoke exhaust system may have. nual start functions
guards against such errors.
Thus, where a fan is started or ener- • Visual inspection of fans and smoke
Indoor fan installation outside the gized via a suitable switchgear devi- exhaust dampers
fire compartment ce, all thermal or electrical monitoring • Review of smoke extraction scenari-
Fans for this application type must be components must be bypassed or de- os with regard to triggering, damper
heat insulated when installed in a energized, and all switching devices positioning and fresh air supply
ventilated room. Data concerning the must be rated for the projected
requisite nominal air flows which must (usually, maximum) fan rpm. The fan • Sample check of individual volume
be ensured to keep the air temperatu- speed must NOT be variable for the flows and comparison with the ac-
re in the installation room below 40°C duration of the fire, and indeed, such ceptance condition
under any fan operating condition are speed control would be counterpro-
available from the manufacturer upon ductive. Another important require-
request. ment is that all devices have under-
gone an appropriate acceptance pro-
Insulation in the form of wire-net mi- cedure.
neral fiber matting may be applied re-
troactively in a single layer. The This acceptance must be conducted
thickness of the lagging must exceed and documented at the system ope-
40 mm, at an apparent density > 90 rator's initiative. The acceptance tests
kg/m3. Note also that the insulation shall determine the system's full ope-
material for fire-resistant air ducting rability and appropriate installation,
must meet DIN 4102, Part 4. As re- and specifically the proper interaction
gards electrical wiring, routing and of all components. In the functional
execution requirements vary with the test, the fan's power consumption at
installation site. In any case, cables normal temperatures of about 20°C
shall conform to the circuit integrity must not exceed permissible values
SMOKE (FUME) EXHAUST FANS
INSTALLATION EXAMPLES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 033


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

The ideal mounting configuration 2,5 x D 2,5 x D


corresponds to that of the test airflow
duct, with inlet and outlet tube
diameters of 2.5 x D (D = fan diameter).

Fig. 1

200

On free inlet fans, the use of an


optimized bellmouth is mandatory. Connections of the above type are
Failure to install this would result in absolutely unacceptable in practice.
severely degraded fan performance
Flexible duct connectors upstream and increased noise levels.
and downstream of the fan must be 2,5 x D
fitted carefully with zero offset, taking
into account the installed length.
Failure to observe this rule will result
in performance loss and increased
acoustic emissions. Flexible
connectors are not intended as In special cases, i.e., where no
“elastic fit“ adapters compensating for To satisfy accident prevention rules, a alternative is feasible, an adapter
installation inaccuracies! wire guard must be fitted to the front cone and 2.5 D tube section (D = fan
of the bellmouth. diameter) must be fitted as shown.
Fig. 2/2.1/2.2 Fig. 3/3.1 Fig. 4/4.1

Where dampers must be fitted in


airflows arriving vertically from below With horizontal approach flows from a Installation of an axial-flow fan directly
(e.g., through a ceiling or inlet duct), larger duct or inlet chamber, an downstream of a curved duct section
an opposed-blade damper type should oversized flexible connector (two will give rise to substantial perfor-
be used to ensure an appropriate nominal sizes > nominal fan size) in mance losses and noise increase.
approach flow onto downstream conjunction with the bellmouth will
deflector or baffle elements. greatly improve incoming flow
conditions and noise output.

a
Baffles
Opposed-
blade
damper
b
b = 0,6 x a
at least five, ideally
more (e.g., 8
baffles)

The flexible duct connector (two If a 2.5 x D inlet flow section cannot
nominal sizes > nominal fan size) be fitted, baffles should be used (for
ensures an additional improvement in An approach flow situation as shown configuration and sizes refer to Fig.
incoming flow conditions and superior in Fig. 6 will result in a greatly 5.1)
acoustic performance. impaired fan performance.
Fig. 5/5.1 Fig. 6/6.1 Fig. 7/7.1
SMOKE (FUME) EXHAUST FANS
INSTALLATION EXAMPLES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 034


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Maximum impact loss 50% reduced impact loss 70% reduced impact loss

Free outlet Free outlet


Free outlet

2,5 x D Diffuser with core

In a free-outlet configuration, the On a free outlet system with 2.5 x D Diffusers can reduce impact loss by
dynamic pressure acting on the fan’s outlet duct, the entire surface area as about 70% when compared to the
annular surface area (fan surface determined from the nominal fan size configuration shown in Fig. 8.
minus hub surface) must be taken into may be used for the impact loss
account as impact loss. calculation (rectified flow).
Fig. 8/8.1/8.2

High impact loss In-chamber installation

0,5 x nominal fan size

The same applies by


analogy for
installation in tube or
channel ducts.
To avoid high impact loss, turbulence 1 x nominal fan size
effects and excessive noise, + at least 1 m
downstream splitter attenuators
should be connected via a diffuser
with internal core and an interposed
pressure chamber. In systems with In practice, fans are often mounted in roofs), the availability of sufficiently
large cross sections, the pressure such cramped conditions that proper strong support areas is important. It
chamber may be additionally provided maintenance or repairs are impossible should be possible to erect scaffolding
Curved leading ends Baffle screen or extremely costly to carry out. Fans above and around the fans for
are machines which comprise wearing installation and maintenance.
parts. It is therefore important to
provide adequate free space around
the unit for maintenance or repair
access. On roofs (especially warm
Diffuser with Fig. 11
core
with a built-in baffle screen (perforated
metal panel). This recommendation Plenum inlet
0,5 x D
also applies to filters, heaters, etc. chamber
The splitters should have curved
leading ends.
Vortex flow effects
are often en-
Fig. 9/9.1 countered in confi-
gurations of this
type. The use of Baffle-
0,5 x D an anti-vortex front view Baffle -
side view
baffle is
recommended.

min.
0,5xD In large inlet chambers with multible air Please also observe other fan
streams, vortex effects may impair the technology fundamentals as described
airflow at the fan inlet. Performance in the relevant academic and trade
For in-chamber installation specified losses are an inevitable result. In this literature (e.g., TLT Fan Primer,
minimum distance must be observed. type of operating situation, the published by Promoter Verlag,
If multiple fans are mounted next to recommended anti-vortex baffle should Karlsruhe). Our staff will be glad to
each other, the distance between their either be fitted from the start or planned answer your questions on this subject.
bellmouths must be at least 0.5 D. in such a way it can be installed later.

Fig. 10 Fig. 12
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 035


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

8.0 Individual system components b) the open position (during extrac- Such equipment is designated
tion of hot gases). ETK90, i.e., it has a fire resistance of
8.1 Smoke exhaust dampers 90 minutes at the ISO 834 unit-tem-
Moreover, their power supply must be perature curve (in the future, the rele-
Since work on the relevant European vant document will be EN 1363-1),
reliably ensured since a smoke ex-
standard (prEN 1366-10) is still conti- and its smoke extraction functionality,
haust damper is required to retain its
nuing, the relevant national approval based on the same curve, remains
opening and closing capability even
mechanisms have remained applica- ensured for the same period.
after 25 minutes of fire exposure, so
ble. In Germany, these are enshrined
that consistent with the Model Guide-
in the Building Rules List established
line for Ducting (draft 98), the exhaust
by the new Building Code (the cur-
duct equipment will remain operable
rently valid list is designated 99-1).
for at least 90 minutes.
According to this document, all smo-
ke exhaust dampers require approval
by the building supervisory authority. The drive units for smoke exhaust
dampers are tested for a fire resi-
Smoke exhaust dampers are known stance of 90 minutes. In the case of a
to have two safety positions: power failure, the de-energized drive
units must secure the damper in its
a) the closed position (standby, with open position, e.g., via a mechanical
or without fire resistance) locking feature.

8.2 Smoke exhaust ducts value measured in the test, e.g., 40


mm for a 1.5 m (uncovered) hanger.
The fire resistance behaviour of smo-
For longer elements to remain within
ke exhaust ducts is currently gover-
this elongation range, they must be
ned by the national standard DIN
enclosed in a fire-resistant material.
4102-6, while their smoke extraction
capabilities are subject to DIN 18232-6. The tightness of the ductwork is an-
DIN 4102-6 is scheduled to be repla- other criterion. Practical experience
ced within the next 6 months by EN shows that ducts assembled on site
1366-1, while DIN V 18232-6 will re- exhibit the greatest installation flaws.
main applicable until the European Leakage flows shall not exceed 10
standard for smoke exhaust ducts m3/h per square meter of inside sur-
(EN 1366-8) becomes available. This face area. Thus, for instance, an Li
is expected to happen in about two 1.0 x 1.0 m duct has an interior cir-
years' time. cumference of 4.0 meters, and a 5-
The differences between the two Eu- meter length of this duct has an insi-
ropean standards and their German de surface area of 20.0 m.
counterparts are minimal, except for Its maximum acceptable leakage
the characteristics and length of the would thus be 2.0 x 10 = 200 m3/h. In
suspension elements. The calculati- the case of multi-range systems, allo-
ons use the same baseline value of wance must also be made for permis-
6 N/mm2. sible cold leaks of 200 m3/h per squa-
With the publication of DIN EN 1366- re meter of cross-sectional area
1, this European specification has co- (smoke exhaust dampers) and for the
me to reflect the state of the art. It is acceptable exhaust fan power loss.
to replace DIN 4102, Part 6. In sizing a smoke exhaust fan, all ac-
According to the European testing cri- ceptable sources of leakage or power
teria, the elongation of the suspensi- loss have to be duly taken into ac-
on elements must be measured and count.
recorded in the test record upon com-
pletion of the fire test. The measured
elongation applies for a maximum
hanger length of 1.5 m. Where longer
suspension elements are needed,
their elongation shall not exceed the
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 036


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

DIN...
Engineering Standards Contents
EN...
Smoke exhaust fans DIN V Mechanical smoke exhaust systems
18232-6 Requirements for components
and suitability testing

EN 12101-3 Smoke and heat control systems


Part 3: Specification for mechanical
smoke and heat exhaust ventilators
(test and product standard)

Fire protection dampers DIN Fire protection dampers


EN
1366-2

Smoke exhaust dampers DIN V Mechanical smoke exhaust systems


18232-6 Reqirements for components
and suitability testing

Ducting DIN V Mechanical smoke exhaust systems


18232-6 Requirements for components
and suitability testing

DIN 1366-1 Fire resistance tests on service installations,


Fire-resistant ventilation ducts

pr EN Fire resistance tests on service installations


1366-8 in buildings, Smoke extraction ducts

pr EN Fire resistance tests on service installations


1366-9 in buildings
Smoke extraction ducts in a fire zone

Sizing of smoke exhaust systems DIN V Smoke and heat extraction systems
18232-5 Mechanical smoke exhaust systems
Requirements and design

pr EN Smoke and heat protection systems


12101-5 Functional requirements and calculation
methods for smoke and heat exhaust systems

Pressure-based smoke protection systems DIN 18232-7 Smoke and heat extraction systems
(draft) Pressure-based smoke protection
systems for safety staircases

pr EN Smoke and heat control systems


12101-6 Pressure differential systems, kits

Smoke exhaust systems pr EN Smoke and heat control systems


12101-4 Design of smoke and heat exhaust systems
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 037


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

8.3 Control of smoke exhaust the arrival of fire-fighting services. To Obviously, all triggering devices must
systems ensure the direct and immediate ac- be approved by the building supervi-
tivation of the smoke exhaust system, sory authorities. The layout and num-
8.3.1 Triggering devices and smoke extraction fans must be equip- ber of smoke detectors used must
single-range systems ped with automatic triggering devices conform to DIN VDE 0833-1.
that sense the presence of smoke
Smoke exhaust fans and fire protec- (smoke detectors).
tion dampers must be approved by
Smoke exhaust systems designed for
the German Institute of Building
human safety must not require ma-
Technology (DIBt) according to Buil-
nual activation, since the occupants
ding Rules List "B", Part 2, in conjunc-
at risk must be able to leave the buil-
tion with the relevant smoke detec-
ding safely within the first few minutes
tors. Compliance with the codes is
after a fire has started. If, in the cour-
demonstrated via certification tests
se of the planning process, the fire
performed by independent testing in-
authorities should insist on manual
stitutes.
activation by the fire brigade, the sy-
The smoke exhaust system is trigge- stem no longer qualifies as a smoke
red by pushbuttons or automatically exhaust installation for human safety,
via smoke detection switches. The since experience shows that it will
signals that activate the mechanical usually take 5 – 15 minutes for fire
heat and smoke exhaust installation fighters to arrive.
and move the fire protection and smo-
The foregoing does not apply where
ke exhaust dampers into their safety
smoke exhaust dampers form part of
position are transmitted by a control-
the smoke exhaust system. In this ca-
ler. The various devices cooperate to
se the fans may be integrated with the
ensure a high-speed fire detection,
wiring of the smoke exhaust damper
alarm, and smoke exhaust.
and the associated triggering device,
Past fire disasters have shown that which meets the same protection ob-
an effective rescue of human beings jective. Still, it must be possible to
can only be achieved through an ear- start the fans manually via pushbut-
ly and effective extraction of smoke tons.
from escape and safety routes until

Roof-mounted smoke exhaust fan

Smoke detection switch Smoke detection switch

Smoke-free layer

Pushbutton switch
Building
services
management
Air supply Controller
system
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 038


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

8.3.2 Control via LON bus Bus communication between exhaust system and controller
(ICI)

Management
The integration of all equipment such
as central fire detection, emergency METASYS“

level
lighting and fire compartment doors operating station
into the building services automation
structure provides an overall functio-
N1 network, Ethernet using TCP/IP
nality and comprehensive control at 10 Mbps or
capability offering numerous benefits.
On one hand, it ensures that escape METASYS“ network
Automation

and rescue routes will be kept clear of processor


level

smoke for a defined interval to protect Integration of fire


occupants and fire-fighting services. alarm systems, etc.
On the other, it enables a continuous N2 bus, 10 Kbps
documentation of all processes in
conjunction with the building services
SBKM safety bus SBKM safety bus
automation system allowing full re- communication communication
cords of incidents for subsequent module for fire module for smoke
analysis. In addition, maintenance- protection dampers exhaust dampers
Field level

free fire protection dampers (or dam-


pers with extended service intervals)
can be installed if the system allows Smoke exhaust panel
these units to be periodically actuated Joventa drive unit with Joventa reversible drive
spring return units
with full performance logging. High
maintenance costs can thus be effec-
tively reduced, given that according to
the "General Building Supervision Cost saving and more security are arguments in favour of N2 bus wiring in buil-
Approval", conventional fire protec- ding services automation controling a smoke extraction system.
tion dampers must be serviced an-
nually.

Considerable cost savings


Bus communication is a key advanta-
ge of digital building automation solu-
tions. It implies considerable cost sa-
vings because of a significant reduc-
tion in installation costs. The need for
traditional star-pattern wiring, with its
high cabling investment (at least E30
for smoke exhaust applications), is
eliminated. This is illustrated in the
following example.

At the field level the bus is arranged


as a ring circuit for the transmission of
data and control signals, thus offering
a high degree of safety. From the
control module the individual actua-
ting motors of the smoke exhaust and
fire protection dampers are fed and
operated via a 2-wire system (power a bus system can ensure a full clo-
supply plus data/control signals). The sed-loop and open-loop control of the
amount of cabling required and hen- smoke extraction process without ad-
ce, the fire load, are greatly reduced. ditional interfaces, with full integration
The 2-wire connections can even be into the building automation system
interchanged during assembly. Only for the entire building.
ROOF-MOUNTING SMOKE EXHAUST FANS
PRODUCT RANGE
TECHNICAL DESCRIPTION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 039
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Characteristic curves as of page 041 Characteristic curves as of page 151

BVD series BVW-D series


Temperature/Time category acc. to Temperature/Time category acc. to

Roof-mounting Smoke exhaust fans BVD · BVW-D


EN 12101 - part 3: EN 12101 - part 3:

F 400 400°C - 120 min. F 600 600°C - 120 min.


F 600 620°C - 120 min.
Product range: Product range:
6 sizes 6 sizes
more than 100 types more than 35 types
Volume flow up to 51500 m3/h Volume flow up to 48000 m3/h
additional pressure up additional pressure up
to appr. 1900 Pa to appr. 2000 Pa

Technical description Technical description


BVD series BVW-D series
Vertical outlet, casing made of corro- Direct-drive type, consisting of casing
sion-resistant aluminium. Centrifugal and impeller made of steel sheet, pro-
impeller, single intake type, made of tected by an polyester powder coa-
sheet steel, dynamically balanced to ting, colour RAL 7030, with bellm-
DIN ISO 1940, Quality Grade G 6,3. outh, motor support plate, companion
Surface finished with powder coating. flange as per DIN 24154, Series R3,
companion frame as per DIN 24193,
Mounting plate made of sendzimir-
Series R2.
galvanized sheet steel with deep-
drawn bellmouth, stud-bolts for direct Centrifugal impeller, single inlet type,
flange attachement of accessories. aerodynamically optimized, dynami-
cally balanced to DIN ISO 1940, qua-
Direct drive three-phase a. c. type
lity grade G 6,3.
IEC standard motor, type V1, ISO
class H Protection class: IP54, enclo- Three-phase a.c. motor as per IEC
sed against the flow, with separate standard, style V1, Protection class
forced-air motor cooling system. El- IP 55, ISO class H
ectrically wired to exterior terminal
Motor enclosure:
box or maintenance switch.
Round sheet steel housing, cooling
air supplied via cooling air inlet duct.
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400/620°C – 120 MIN 040
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Steel flat roof base


ØD - double shell type

B
 B3
C

350
H  B1
40

A
Base plate 1) SDS Noise damping base

B
 B3 M
Øe

110
NW
 B3

cable-
A

duct
H1
d

Øk Y
Flexible connector  B2
Øk

L (400°C) = 200 mm
L (620°C) = 90 mm
Customer-supplied base

B

Self-activating shutoff damper  B3


– for free inlet – for duct connection
350

Ø D1 Ø D1
Øk z x Ø d1 Øk
L

 B4

Ø d1 Ø d1
Ø D2

2) Stud  B4
Size Ø D  A  B3 H Ø D1 Ø D2 d bolt y Ø d1 Ø k zx Ø d1 L B1  B  C H1 B2 Ø e NW
M min. - max.

315 638 560 460 695 386 369 14 12x25 8xM8 322 356 8 x 9,5 180 765 525 400 - 420 421 780 823 326 80

355 808 710 600 772 425 407 14 12x25 8xM8 360 395 8 x 9,5 180 975 675 450 - 540 565 810 981 365 80

400 808 710 600 848 468 451 14 12x25 12xM8 404 438 12 x 9,5 180 975 675 490 - 540 565 810 981 408 80

500 993 1000 880 923 571 586 18 16x25 12xM8 507 541 12 x 9,5 305 1265 965 600 - 830 850 850 1274 511 100

630 1272 1000 880 1337 712 730 18 16x25 16xM10 638 674 16 x 11,5 305 1265 965 750 - 820 850 900 1274 642 100

710 1272* 1160 1040 1337 785 798 18 16x25 16xM10 715 751 16 x 11,5 305 1425 1125 900 - 965 1000 930 1427 719 100
1) Flanges as per DIN 24 154, Series 3. An inlet wire guard can be 2) BVD 315/30-2 = 744 mm Dimensions in mm
fitted directly to the base plate or flanges. * 1500 mm with 710 XL
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


400/620°C – 120 MIN 041
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Type Weight Speed Motor Nominal Volume flow (m3/h)


BVD 315/30 approx output current
1700 Free inlet Free inlet
3000 rpm
at without with
400 V shutoff shutoff
1600 50 Hz damper damper
[kg] [rpm] [kW] [A]
-2
1500 BVD 315/30-8 50 670 0,12 0,65 2500 2250
BVD 315/30-8/12 50 700/470 0,22/0,08 1,0/0,7 2500/1100 2250/1050
␦ BVD 315/30-6 50 930 0,18 0,82 3200 2800
1400 = 1,2 kg/m3 BVD 315/30-6/12 50 890/400 0,25/0,044 0,9/0,38 3200/1100 2800/1050
t = 20°C BVD 315/30-6/8 50 920/700 0,22/0,11 0,9/0,72 3200/2500 2780/2250
BVD 315/30-4 50 1380 0,55 1,4 4900 4500
1300 BVD 315/30-4/8 50 1410/670 0,5/0,12 1,5/0,7 4900/2500 4500/2500
BVD 315/30-4/6 50 1410/920 0,55/0,18 1,45/0,8 4900/3200 4500/2800
1200 BVD 315/30-2 70 2880 4,0 8,5 9700 9050
BVD 315/30-2/4 70 2890/1440 4,1/1,0 9,1/2,0 9700/4900 9050/4050

1100 Acoustic levels in the room (inlet side)


Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
1000
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
900 Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
800 670 75 62 47 4,6 4,3 7,6 19,2 22,3 23,6 24,2 34,6
930 81 70 55 4,5 4,6 6,3 12,4 20,1 23,5 22,4 28,6
1380 88 79 65 5,1 6,6 5,0 9,6 17,0 20,2 21,3 22,2
700
2880 102 97 85 6,0 8,0 9,0 4,0 12,0 15,0 18,0 19,0
Influence of the self-activating shutoff damper: +3 dB
600
Additionally available pressure pt1 [Pa] ➞

Acoustic levels above roof (outlet side)


500 Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
1500 rpm
background noise influence K1 = 0 dB, directional factor -3 dB
400 -4
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
300 Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
1000 rpm per 670 74 69 43 6,4 6,6 3,7 15,9 12,7 12,3 12,4 23,5
200 dam teristics
toff 930 80 75 50 7,6 7,4 4,1 11,0 11,7 13,0 11,7 18,7
Shu charac
750 rpm -6 nce 1380 86 83 57 9,2 10,3 4,8 8,6 9,5 10,7 11,4 13,5
re sista
100 2880 100 98 73 13,0 8,0 10,0 7,0 10,0 9,0 11,0 13,0
-8 Influence of the self-activating shutoff damper: + 2 dB
1) L = Total acoustic power level LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
1000 2000 3000 4000 5000 6000 7000 8000 9000 W
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.

Type Weight Speed Motor Nominal Volume flow (m3/h)


BVD 355/30 approx output current Free inlet Free inlet
700 at without with
400 V shutoff shutoff
50 Hz damper damper
[kg] [rpm] [kW] [A]
BVD 355/30-8 76 670 0,12 0,65 3300 3000

= 1,2 kg/m3 BVD 355/30-8/12 76 700/470 0,22/0,08 1,0/0,7 3300/2150 3000/2000
600
t = 20°C BVD 355/30-6 76 910 0,25 0,86 4750 4100
BVD 355/30-6/12 76 890/400 0,25/0,044 0,9/0,38 4750/2150 4100/2000
BVD 355/30-6/8 76 920/700 0,22/0,11 0,9/0,72 4750/3300 4100/3000
1500 rpm
BVD 355/30-4 76 1390 1,1 2,8 7050 6550
BVD 355/30-4/8 76 1400/700 1,0/0,25 2,4/1,0 7050/3300 6550/3000
500
BVD 355/30-4/6 76 1430/950 1,1/0,37 2,8/1,35 7050/4750 6550/4100

-4 Acoustic levels in the room (inlet side)


Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
BVD

background noise influence K1 = 0 dB, room influence K2 = 5,2 dB

400 Speed Acoustic level 1) Relative acoustic power level


at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
470 71 57 42 2,3 4,3 9,8 21,1 23,5 21,2 27,0 39,9
670 77 65 51 3,9 4,4 6,9 18,9 21,8 21,3 21,1 31,1
300 910 82 72 58 4,2 4,3 7,2 12,1 18,6 21,4 18,1 23,1
1390 90 82 68 5,2 6,7 5,0 9,7 16,8 19,3 19,0 17,0
Influence of the self-activating shutoff damper: +3 dB
1000 rpm
Additionally available pressure pt1 [Pa] ➞

-6 Acoustic levels above roof (outlet side)


200 Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB

Speed Acoustic level 1) Relative acoustic power level


750 rpm at V max. Lw rel. = Lw – Table value
-8 Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
100
per
dam teristics 470 69 63 38 4,5 4,9 8,6 17,4 12,1 10,4 15,0 29,1
500 rpm toff
Shu charac 670 76 71 46 7,5 6,8 4,3 16,4 12,1 11,9 10,4 21,5
n c e
resista 910 82 79 53 8,8 7,0 5,6 11,0 9,9 12,9 8,0 14,5
1390 90 87 62 10,6 10,4 5,7 9,0 8,8 11,7 10,0 9,3
-12
Influence of the self-activating shutoff damper: + 2 dB
1000 2000 3000 4000 5000 6000 7000 1) L = Total acoustic power level LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
W
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


400/620°C – 120 MIN 042
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVD 400/30 Type Weight Speed Motor Nominal Volume flow (m3/h)
approx output current Free inlet Free inlet
at without with
400 V shutoff shutoff
50 Hz damper damper
800 ␦
[kg] [rpm] [kW] [A]
= 1,2 kg/m3
t = 20°C BVD 400/30-8 85 670 0,37 1,45 4900 4600
BVD 400/30-8/12 85 700/470 0,22/0,08 1,0/0,7 4900/3100 4600/2900
1500 rpm BVD 400/30-6 85 920 0,55 1,6 6250 6000
700 BVD 400/30-6/12 85 900/420 0,33/0,055 1,15/0,33 6250/3100 6000/2900
BVD 400/30-6/8 85 920/700 0,44/0,22 1,45/0,95 6250/4900 5950/4000
BVD 400/30-4 85 1410 1,5 3,5 9600 9150
BVD 400/30-4/8 85 1400/690 1,4/0,35 3,3/1,35 9600/4900 9150/4600
BVD 400/30-4/6 85 1430/960 1,6/0,6 3,9/1,8 9600/6250 9150/5950
600
-4 Acoustic levels in the room (inlet side)
Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
500 Relative acoustic power level
Speed Acoustic level 1)
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
470 77 64 49 3,1 5,6 8,5 20,8 23,9 20,7 24,3 38,6
400
670 86 75 61 4,4 4,3 7,4 18,0 20,2 22,2 18,7 27,0
920 92 83 69 5,0 4,5 6,7 10,7 18,6 21,7 18,4 21,9
1410 98 90 76 7,3 8,8 2,7 10,4 18,0 20,3 21,4 18,2
1000 rpm Influence of the self-activating shutoff damper: +3 dB
300
Additionally available pressure pt1 [Pa] ➞

-6 Acoustic levels above roof (outlet side)


Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
200
750 rpm
-8 Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
100 per 470 73 68 43 6,9 6,4 4,4 16,5 13,1 11,2 12,9 29,0
dam teristics
toff
500 rpm Shu charac 670 82 78 52 9,1 6,6 4,9 14,4 10,6 13,7 8,5 18,1
-12 tanc
e
resis 920 89 85 60 10,9 7,1 4,5 9,6 10,1 14,6 9,5 14,3
1410 97 93 68 13,4 12,0 3,5 8,6 9,5 13,5 12,8 11,1
Influence of the self-activating shutoff damper: + 2 dB
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 1) L = Total acoustic power level LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
W
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.

BVD 500/30 Type Weight


approx
Speed Motor
output
Nominal
current
Volume flow (m3/h)
1200 Free inlet Free inlet
at without with
400 V shutoff shutoff
1500 rpm 50 Hz damper damper
1100 [kg] [rpm] [kW] [A]
-4 ␦
= 1,2 kg/m3 BVD 500/30-8 148 690 0,75 2,2 8500 8200
t = 20°C BVD 500/30-8/12 148 710/470 0,55/0,18 2,5/1,18 8500/5500 8200/5300
1000 BVD 500/30-6 148 910 1,1 3,15 11500 10900
BVD 500/30-6/12 148 910/450 1,5/0,3 3,8/1,35 11500/5500 10900/5300
BVD 500/30-6/8 148 940/710 1,3/0,66 3,3/2,3 11500/8500 10900/8200
900 BVD 500/30-4 160 1420 4,0 9,0 17000 16000
BVD 500/30-4/8 190 1400/700 5,5/1,4 11,4/4,3 17000/8500 16000/8200
BVD 500/30-4/6 190 1450/960 4,5/1,5 9,5/3,8 17000/11500 16000/10900

800 Acoustic levels in the room (inlet side)


Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
700 Relative acoustic power level
Speed Acoustic level 1)
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
600
470 81 66 51 2,3 5,3 8,2 21,1 24,9 29,7 34,8 40,0
690 88 76 62 4,8 4,2 6,3 12,9 21,8 26,2 31,1 36,3
950 93 83 69 5,0 3,9 8,0 10,8 19,2 22,7 27,5 32,6
500 1000 rpm
1420 104 95 82 5,0 7,0 6,0 10,0 15,0 23,0 28,0 33,0
-6 Influence of the self-activating shutoff damper: +3 dB
Additionally available pressure pt1 [Pa] ➞

400
Acoustic levels above roof (outlet side)
Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
300
750 rpm
Speed Acoustic level 1) Relative acoustic power level
-8 at V max. Lw rel. = Lw – Table value
200 Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
per s
dam teristic 470 78 69 45 6,8 4,9 3,7 14,8 13,8 19,6 23,8 31,2
500 rpm toff c
Shu chara
n c e 690 86 78 54 10,5 5,6 3,2 11,3 12,4 17,8 21,9 29,2
100 -12 re sista
950 92 87 62 10,7 5,6 5,5 7,3 9,9 14,4 18,3 25,2
1420 101 97 73 8,0 8,0 6,0 10,0 9,0 15,0 18,0 19,0
Influence of the self-activating shutoff damper: + 2 dB
2000 4000 6000 8000 10000 12000 14000 16000 1) L = Total acoustic power level
W LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


400/620°C – 120 MIN 043
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVD 630/25 Type Weight


approx
Speed Motor
output
Nominal
current
Volume flow (m3/h)
1600 Free inlet Free inlet
at
400 V without with
1500 rpm shutoff shutoff
50 Hz
[kg] [rpm] [kW] [A] damper damper

BVD 630/25-8 220 705 1,5 5,15 15700 14800


1400
BVD 630/25-8/12 220 720/450 1,1/0,37 4,0/2,0 15700/10000 14800/9600
-4 ␦
= 1,2 kg/m3 BVD 630/25-6 220 945 3,0 7,4 20800 19700
t = 20°C BVD 630/25-6/12 220 950/470 2,6/0,5 7,1/2,8 20800/10000 19700/9600
BVD 630/25-6/8 220 950/720 3,3/1,5 9,3/4,4 20800/15700 19700/14800
BVD 630/25-4 240 1460 9,2 20 31500 29600
1200 BVD 630/25-4/6 295 1460/970 12/3,5 24/9,5 31500/20800 29600/19700
BVD 630/25-4/8 285 1440/720 11/3,0 24/9,5 31500/13700 29600/14800

Acoustic levels in the room (inlet side)


Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
1000
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB

Speed Acoustic level 1) Relative acoustic power level


at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
800 rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
450 84 71 57 2,5 6,4 7,9 18,7 22,0 26,7 31,8 37,0
705 91 81 68 2,5 6,2 8,1 10,7 17,7 21,8 26,7 31,8
945 96 86 73 6,5 2,7 9,4 11,0 17,1 20,2 24,9 30,0
1000 rpm 1460 107 99 86 7,0 2,0 9,0 12,0 14,0 17,0 21,0 26,0
600
Influence of the self-activating shutoff damper: +3 dB
-6
Additionally available pressure pt1 [Pa] ➞

Acoustic levels above roof (outlet side)


Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
400
750 rpm
-8 Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
per
200 dam teristics 450 83 75 51 7,1 4,5 6,6 10,8 12,1 16,9 22,8 30,1
toff
500 rpm Shu charac
c e 705 90 85 60 6,5 5,9 8,8 5,4 9,9 13,9 19,6 26,9
-12 tan
resis 945 95 91 66 11,9 4,8 10,2 5,1 9,5 12,3 17,9 25,0
1460 107 102 77 16,0 7,0 6,0 7,0 8,0 12,0 15,0 16,0

Influence of the self-activating shutoff damper: + 2 dB


5000 10000 15000 20000 25000 30000 1) L = Total acoustic power level LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
W
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.

BVD 630/30 Type Weight Speed Motor Nominal Volume flow (m3/h)
2000 approx output current Free inlet Free inlet
at without with
400 V shutoff shutoff
50 Hz damper damper
1500 rpm [kg] [rpm] [kW] [A]
1800
-4 ␦ BVD 630/30-8 240 710 2,2 5,4 18300 17400
= 1,2 kg/m3
BVD 630/30-8/12 240 720/470 2,4/0,8 6,8/3,6 18300/11800 17400/11000
t = 20°C
BVD 630/30-6 240 945 5,5 12,7 24800 23200
1600 BVD 630/30-6/12 240 920/460 6,3/1,5 16,6/6,1 24800/11800 23200/11100
BVD 630/30-6/8 240 970/720 4,8/2,4 11,4/6,7 24800/18300 23200/17400
BVD 630/30-4 320 1460 18,5 38 38000 36000
BVD 630/30-4/6 350 1460/980 18/6,0 36/14 38000/24800 36000/23200
1400 BVD 630/30-4/8 350 1460/710 20/5,5 39/16,2 38000/18300 36000/17400

Acoustic levels in the room (inlet side)


Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
BVD

1200
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
1000 rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
470 87 73 59 3,4 5,2 8,3 21,1 23,6 28,1 33,1 38,3
710 96 86 72 5,4 4,2 6,5 11,2 19,8 23,4 28,2 33,3
945 101 90 76 9,6 1,3 9,8 14,1 18,5 24,6 29,0 23,0
800 1000 rpm 1460 111 104 91 6,0 7,0 3,0 10,0 13,0 17,0 21,0 26,0
Influence of the self-activating shutoff damper: +3 dB
-6
Additionally available pressure pt1 [Pa] ➞

Acoustic levels above roof (outlet side)


600 Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
750 rpm
-8 Speed Acoustic level 1) Relative acoustic power level
400 Lw rel. = Lw – Table value
at V max.
Octave center frequency [Hz]
per rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
dam teristics
toff
Shu charac 470 86 77 53 6,9 3,9 7,0 13,0 13,7 18,3 24,1 31,4
500 rpm nc e
200 ta
resis 710 95 89 65 10,4 5,1 7,0 5,6 11,7 15,2 20,8 28,0
-12 945 100 94 69 14,5 2,7 9,4 7,7 9,2 16,2 21,5 28,6
1460 110 105 82 15,0 2,0 8,0 10,0 14,0 16,0 18,0 26,0
Influence of the self-activating shutoff damper: + 2 dB
5000 10000 15000 20000 25000 30000 35000 1) L = Total acoustic power level
W LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


400/620°C – 120 MIN 044
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVD 710/30 Type Weight


approx
Speed Motor
output
Nominal
current
Volume flow (m3/h)
2000 Free inlet Free inlet
at without with
1500 rpm 400 V shutoff shutoff
50 Hz damper damper
␦ [kg] [rpm] [kW] [A]
1800 = 1,2 kg/m3
t = 20°C BVD 710/30-8 270 710 2,2 5,4 24000 23000
-4 BVD 710/30-6 270 945 5,5 12,7 32000 30500
BVD 710/30-6/8 355 980/720 7,0/3,5 15,5/9,4 32000/24000 30500/23000
1600 BVD 710/30-6/12 270 950/460 6,3/1,5 16,6/6,1 32000/16000 30500/15000
BVD 710/30-4 405 1460 18,5 38 47000 46000
BVD 710/30-4/6 460 1480/980 20/7,0 41/16,2 47000/32000 46000/30500
BVD 710/30-4/8 435 1460/710 20/5,5 39/16,2 47000/24000 46000/23000
1400
Acoustic levels in the room (inlet side)
Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
1200
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
1000 rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
475 89 77 64 1,6 8,2 8,7 13,9 18,4 22,8 27,8 33,0
710 97 87 74 8,0 3,0 6,0 13,0 15,5 19,0 23,8 28,9
945 102 95 82 9,3 3,8 4,2 13,8 15,0 17,3 21,8 26,8
800 1000 rpm 1460 109 100 87 14,0 15,0 1,0 16,0 19,0 18,0 21,0 26,0
Influence of the self-activating shutoff damper: +3 dB
-6
Additionally available pressure pt1 [Pa] ➞

Acoustic levels above roof (outlet side)


600 Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
750 rpm
-8 Speed Acoustic level 1) Relative acoustic power level
400 at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
per 475 89 83 58 4,8 8,3 9,0 7,2 11,6 14,7 21,1 28,1
500 rpm dam teristics
200 toff
-12 Shu charac 710 96 92 67 12,7 5,7 6,6 6,4 9,0 11,1 17,2 24,2
e
tanc 945 102 98 73 15,5 5,5 5,1 8,3 10,0 10,9 16,7 23,6
resis
1460 108 104 79 15,0 6,0 1,0 9,0 12,0 11,0 15,0 21,0
Influence of the self-activating shutoff damper: + 2 dB
10000 20000 30000 40000 1) L = Total acoustic power level L
W WA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.

Type Weight Speed Motor Nominal Volume flow (m3/h)


BVD 710/30 XL approx output current Free inlet Free inlet
2000 at without with
400 V shutoff shutoff
50 Hz damper damper
1500 rpm
[kg] [rpm] [kW] [A]

1800 = 1,2 kg/m3
t = 20°C BVD 710/30 XL-4 420 1470 22 43 51500 50000
BVD 710/30 XL-4/6 475 1470/970 25/9,0 47/18,5 51500/33500 50000/32000
-4 BVD 710/30 XL-4/8 420 1470/725 24/6,0 46/14,5 51500/24000 50000/23000
BVD 710/30 XL-6 315 965 7,5 15,7 33500 32000
1600
BVD 710/30 XL-6/12 315 975/475 7,5/1,85 19/6,7 33500/16300 32000/15500

1400
Acoustic levels in the room (inlet side)
Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
1200
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
1000
710 103 93 78 5,0 3,0 13 14 15 18 23 28

1000 rpm 945 107 99 82 4,0 4,0 11 14 13 14 19 24

800 1460 116 110 91 5,0 9,0 6,0 13 13 12 15 20


-6 Influence of the self-activating shutoff damper: +3 dB
Additionally available pressure pt1 [Pa] ➞

Acoustic levels above roof (outlet side)


600 Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
750 rpm
Speed Acoustic level 1) Relative acoustic power level
400 at V max. Lw rel. = Lw – Table value
-8
Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
per
dam teristics
toff 710 100 92,4 71 6,9 2,5 10,1 11,4 11,9 15,2 20 25,1
200
500 rpm Shu charac
nc e
ta
resis 945 105 99 76 7,2 3,1 9,6 12,1 10,9 12,7 17 22
-12
1460 113 110 84 72 9,0 3,0 10 10 9,0 12 17
Influence of the self-activating shutoff damper: + 2 dB
10000 20000 30000 40000 50000 1) L = Total acoustic power level LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
W
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.
– 045 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Roof-mounted smoke exhaust fan, BVD Series


for smoke extraction applications
Tested to EN 12101 - Part 3 (Technical University of
Munich)
- max. 400°C – 120 min.
with general building supervision approval Z-78.1-25.
or - max. 620°C – 120 min.
with general building supervision approval Z-78.1-24

Vertical outlet, direct drive three-phase a.c. type


IEC standard motor, type V1, ISO class H
Protection class: IP54
enclosed against the flow, with separate forced-air motor
cooling system.
Electrically wired to exterior terminal box
or maintenance switch.
Mounting plate made of sendzimir-galvanized sheet steel
with deep-drawn inlet nozzle, stud-bolts for direct flange
attachment of accessories.
Casing made of corrosion-resistant aluminium.
Centrifugal impeller, single intake type, made of sheet steel,
dynamically balanced to DIN ISO 1940,
Quality Grade G 6,3
Impeller-surface finished with polyester powder coating,
colour: RAL 7030.

Standard three-phase motor, squirrel cage type


single-speed unit with Dahlander pole-changing type
or pole-changing type with separate windings

Specifications:
Volume flow m3/h
Temperature (design) 20°C
Temperature (max./withstand time) °C/min
Additionally available pressure Pa
Motor speed rpm
Motor output kW
Motor winding V
BVD

Current consumption A
Operating voltage V
Frequency Hz
Acoustic pressure level LPA dB
above roof level, r = 4 m
Weight kg

Manufacturer: TLT-Turbo GmbH

Type: BVD

Carryover
– 046 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment
Surface protection
• Polyester powder coating (standard colour: RAL 7030)
• Wire guard on inlet side (with free inlet configurations)
• Wire guard on outlet side
• Self-activating shutoff damper for free inlet systems, with
nozzle shaped inlet and mounting flange
or • Self-activating shutoff damper for duct connection, with
connecting flanges on both ends
• Flexible connector made of temperature-resistant
compensator fabric, with connecting flanges on both
ends.
• Matching flange
• Steel flat roof base made of sendzimir-galvanized sheet
steel, with interior insulation
- for flat roofs
- for inclined roofs, __° gradient
or • Steel flat roof base made of sendzimir-galvanized sheet
steel, double-shell design, with building supervision
approval
- for flat roofs
- for inclined roofs, __° gradient
• Outlet attenuator SDI, with vertical air outlet
Consisting of the interior core made of galvanized
perforated sheet, integrated into the fan housing and the
non-inflammable insulation material covered with a layer
of non-woven glass fiber
Tested to EN 12101-part 3
Silencing: appr. 5 to 7 dB
• Silencing base SDS for inlet-side silencing, consisting of
the base construction with roof integration flange made of
sendzimir-galvanized sheet steel and the duct-attenuator
with galvanized perforated sheet cover.
For easy wiring the base is equipped with an integrated
cable duct.
Tested to EN 12101-part 3
- for flat roofs
- for inclined roofs, __° gradient
• Additional surface protection:
- Acoustic silencing hood
- Acoustic silencing base
Note: Please observe our Installation, Operating and
Maintenance Instructions (available upon request).
AXIAL SMOKE EXHAUST FANS
PRODUCT RANGE
TECHNICAL DESCRIPTION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 047
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Axial smoke exhaust fans of series: BVAXO · BVAXN 12/56 · BVAXN 8/56 · BWAXO · BWAXN
Characteristic curves as of page 054 Characteristic curves as of page 078 Characteristic curves as of page 101
BVAXO series BVAXN 12/56 series BVAXN 8/56 series
Temperature/Time category acc. Temperature/Time category acc. Temperature/Time category acc.
EN 12101 - part 3: EN 12101 - part 3: EN 12101 - part 3:

F 200 200°C - 120 min. F 200 200°C - 120 min. F 600 600°C - 120 min.
F 300 300°C - 120 min. F 300 300°C - 120 min.
F 400 400°C - 120 Min. F 400 400°C - 120 min.
Appropriate for installation inside of
Appropriate for installation in- and Appropriate for installation in- and fire-zone (cooling-system to be
outside of fire-zone. outside of fire-zone. provided by customer)
Product range: Product range: Product range:
6 sizes 14 sizes 10 sizes
ranging from 400 to 1120 mm diam. ranging from 355 to 1600 mm diam. ranging from 500 to 1600 mm diam.
Volume flow up to 100 000 m3/h Volume flow up to 250 000 m3/h Volume flow up to 180 000 m3/h
total pressure increase total pressure increase total pressure increase
up to appr. 900 Pa up to appr. 2 500 Pa up to appr. 1 400 Pa

Technical description Technical description Technical description


BVAXO series BVAXN 12/56 series BVAXN 8/56-series
Consisting of Casing of welded sheet Casing of welded sheet steel con- Casing of welded sheet steel con-
steel contruction with drilled flanges struction with drilled flanges accor- struction with drilled flanges accor-
according to DIN 24 154, Series 3, ding to DIN 24 154, Series 3; Outlet ding to DIN 24 154, Series 3; Outlet
hub and blades made of cast-alumini- guide vanes for boosting outlet pres- guide vanes for boosting outlet pres-
um, non-adjustable, directly mounted surre and achieving an essentially sure and achieving an essentially
on shaft end of special motor placed swirl-free outlet flow; aluminium im- swirl-free outlet flow; impeller made
within the smoke fume flow, type B3, peller, blade pitch steplessly adjusta- of sheet steel, non-adjustable blades,
protection classe IP 54, wired to exte- ble when fan is at rest, directly mo- directly mounted on motor shaft end.
rior temperature-resistant terminal unted on motor shaft end. Special Motor enclosed and insulated, arran-
box. motor placed within the smoke fume ged in the inner casing. Airflow direc-
flow, wired to exterior temperature-re- tion: motor in outlet, direct-drive type.
Airflow direction: motor in outlet, di- sistant terminal box. Airflow direction:
rect-drive type motor in outlet, direct-drive type. Standard surface protection:
• 2-component polyacylate coating,
Surface protection: Surface protection:
colour: RAL 7030.
• Polyester powder coating, colour: • Polyester powder coating, colour:
RAL 7030 RAL 7030
• as of nominal size 1400: with full
• as of nominal size 1120: with full
paint finish, colour: RAL 7030
paint finish, colour: RAL 7030

Also available with acoustic and Also available with acoustic and  Blades of 400°C/120 min. version are
thermal insulation. thermal insulation. non-adjustable.
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300°C - 120 MIN 048
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Important! This fan series is available only with the motor


outputs stated in our price lists.

Mmax.

2)

Øk

zxd

L i. d.

ØD

No cooling fan required.

Weight
[kg] Motor sizes / Shaft Dia.
Size1) i. d. Øk ØD zxd L Mmax.
(without Type B3
motor)
400 401 438 468 12 x 9,5 188 455 11/16* 90/24 100/28*

500 504 541 571 12 x 9,5 225 570 19/26* 90/24 100/28 112/28* 132/38*

630 634 674 712 16 x 11,5 286 450 27 90/24 100/28 112/28 132/38

800 797 837 875 24 x 11,5 350 575 38 90/24 100/28 112/28 132/38

1000 1003 1043 1081 24 x 11,5 415 805 80 112/28 132/38 160/42 180/48

1120 1124 1174 1214 24 x 11,5 450 825 110 132/38 160/42 180/48 200/55

1) For vibration-damped installation an extension casing will be required with certain fan sizes. Dimensions in mm
* Possible with extension casing only
Dimensional and design
2) available as "turning-anti-clockwise” (seen in airflow-direction) only
changes reserved.

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300°C - 120 MIN 049
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Wire guard, Bellmouth inlet, Mounting feet Mounting feet


inlet side with flange for fans with extension casing or R1 types

ød1 i.L.

Flexible connector Angular Matching flange Extension casing Spring-type


wall ring AV mounts 2)

V 101 / 103 / 105 / 108


i.d2

appr. 60
i.d2
i.d2

V 112 / 120 / 130

length of (same dimensions as appr. 80


installation fan type M-D)

Please mount Flexible Connector correctly and watch installation length.


BVAXO

Size ØD1 i.d1 c H a a1 a2 a3 b b1 z x d3 i.d2 Øk ØD z x d1) e f

400 562 403 78 300 248 218 436 406 370 300 5 x 9,5 403 438 468 12 x 9,5 80 50

500 708 509 98 375 285 255 510 480 460 380 5 x 9,5 506 541 571 12 x 9,5 80 50

630 875 640 95 470 361 321 647 607 550 470 5 x 11,5 637 674 712 16 x 11,5 100 70

800 1081 801 115 585 425 385 775 735 730 640 5 x 11,5 800 837 875 24 x 11,5 100 70

1000 1351 1009 145 730 512 466 927 881 830 740 5 x 14 1006 1043 1081 24 x 11,5 100 70

1120 1470 1130 160 760 547 501 997 951 920 820 5 x 14 1133 1174 1214 24 x 11,5 110 90
1) Connecting dimensions in 2) Height under load will be * all accessories, except duct Dimensions in mm
accordance with DIN 24 154 – communicated upon specification feet and duct extension, are
Series 3 (value is calculated individually for packed separately Dimensional and design
each purchase order). changes reserved.
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300°C – 120 MIN 050
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Brackets for vertical installation

Please refer to pages 065 to


067 regarding acoustic and
thermal insulation for BVAXO
1
series.
welded

Duct with self-activating damper Outlet cone with wire guard


C G L4 L2
Øk

wire guard
zxd L3

Size A  A1  b d1 i.d. Øk ØD z x d1) i.d2 Ø d3 Ø k2 Ø D2 z x d2 L1 L2 L3 L4 C G

400 554 602 68 12 – 438 – 12 x 9,5 – – – – – – 280 60 188 280 40

500 657 705 68 12 504 541 571 12 x 9,5 634 282 674 712 16 x 11,5 600 280 60 225 390 200

630 852 900 90 14 634 674 712 16 x 11,5 797 355 837 875 24 x 11,5 750 330 70 286 465 200

800 1015 1063 90 14 797 837 875 24 x 11,5 1003 446 1043 1081 24 x 11,5 950 520 200 350 550 200

1000 1221 1269 90 14 1003 1043 1081 24 x 11,5 1261 562 1311 1391 24 x 11,5 1200 640 240 415 690 200

1120 1374 1434 100 18 1124 1174 1254 24 x 11,5 1415 630 1465 1545 24 x 11,5 1340 730 250 450 820 300

1) Connecting dimensions in Dimensions in mm


accordance with DIN 24 154 –
Dimensional and design
Series 3
changes reserved.
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 051
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Acoustic level Starting from this value, the A-weigh- ning, respectively. The values given
ted acoustic power level LWA and the were taken from measurements as
relative acoustic power level LWrel. per EN 25136 (formerly DIN 45 635,
The total acoustic power level Part 9) duct testing method.
can be determined using the tables
LW.Vent. (in dB) of an axial smoke ex- below. These values are available as
haust fan can be obtained directly the acoustic power emitted into the
from the characteristic data sheets for duct and as the acoustic power emit-
each operating point. ted from the fan inlet or outlet ope-

1. Acousting power level emitted into the duct Axial Smoke Exhaust Fan BVAXO (without guide vanes)
The level of acoustic power an axial smoke exhaust fan Portion 1.2 at mid-octave frequency [Hz]
emits into the ducting is used for calculating the sound po- z·n
fD = ––––
60
Portion 1.1
wer characteristics of downstream systems, e.g., silencers. 63 125 250 500 1000 2000 4000 8000
The levels are calculated as follows: 500 4 12 9 7 5 11 12 14 15
Lwvent. [dB] = total acoustic power emitted by the fan, 250 6 9 7 4 10 12 13 15 17
(please see respective characteristic curve
125 7 6 4 10 11 13 14 16 21
sheets)
63 8 2 8 10 11 13 15 19 24
LwA vent. [dB] = A-weighted acoustic power level, according
to the equation 31,5 8 6 8 9 11 13 17 21 26

LwA vent. = Lwvent. – portion 1.1 [dB]


fD =
Portion Portion 2.2 at mid-octave frequency [Hz]
Lwrel vent. [dB] = relative acoustic power level as expressed Size* z·n 2.1
60 63 125 250 500 1000 2000 4000 8000
by the equation
315 500 4 24 17 11 6 11 12 14 15
Lwrel vent. = Lwvent. – portion 1.2 [dB] 250 6 21 15 8 12 12 13 15 17
125 8 18 12 14 13 13 14 16 21
400 500 4 22 16 10 5 11 12 14 15
250 6 20 13 7 11 12 13 15 17
125 7 17 10 13 12 13 14 16 21
2. Acoustic power emitted from the fan inlet or outlet 63 8 13 15 13 12 13 15 19 24
opening 500 500 4 21 14 9 5 11 12 14 15
250 6 18 12 6 11 12 13 15 17
To determine the sound levels at a given installation site, 125 7 15 9 11 11 13 14 16 21
63 8 12 13 12 12 13 15 19 24
it is usually necessary to know the level of acoustic power 630 500 4 20 13 8 5 11 12 14 15
emitted from the fan’s inlet or outlet opening. The adjacent 250 6 17 11 6 10 12 13 15 17
tables are based on the outlet reflection pattern assumed 125 7 14 8 11 11 13 14 16 21
63 8 10 12 11 11 13 15 19 24
in VDI 2081, Case 2. 800 500 4 18 12 8 5 11 12 14 15
LwA op. [dB] = A-weighted level of acoustic power emitted from 250 6 15 10 5 10 12 13 15 17
125 7 12 7 10 11 13 14 16 21
the fan’s opening, expressed by the equation 63 8 9 11 11 11 13 15 19 24
1000 250 6 14 9 5 10 12 13 15 17
LwA op. = Lwvent. – portion 2.1 [dB] 125 7 11 6 10 11 13 14 16 21
63 8 8 10 10 11 13 15 19 24
Lwrel op. = relative level of acoustic power emitted from the
fan’s opening, expressed by the equation *Intermediate values to be obtained by interpolation.

Lwrel op. = Lwvent. – portion 2.2 [dB]


BVAXO

Blade frequency of the fan ist calculated from the number of bla-
des z and the fan speed n [rpm].
z · n [s-1]
fD = ––––––
60

Lwvent.
LwAvent.
Amount-linear level

Lwrel.vent.
Amount A

fD Note:
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above
Hz 63 125 250 500 1000 2000 4000 8000 spreadsheets.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXO 200°C - 120 MIN SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 052
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Nominal Output Nominal
Size Size Type Size Size Type
speed [kW] current [A] speed [kW] current [A]
[rpm]  [rpm] 

400 1500 1,1 2,8 90 B3 5 1000 1000 3,0 7,4 132 B3 9


3000 1,5 3,25 90 B3 5 4,0 9,2 132 B3 9
2,2 4,6 90 B3 5 5,5 12,7 132 B3 9
3,0 6,7 100 B3 5 7,5 15,7 160 B3 9
3000/1500 1,5/0,37 3,7/1,0 90 B3 5 1500 7,5 15,4 132 B3 9
2,2/0,48 4,6/1,15 90 B3 5 11 22 160 B3 12
3,0/0,75 6,7/1,7 100 B3 5 15 29,5 160 B3 12
18,5 36 180 B3 12
500 1500 1,1 2,8 90 B3 5 22 43 180 B3 12
3000 3,0 6,7 100 B3 5 30 52 200 B3 12
4,0 8,3 112 B3 5 1500/750 5,5/1,4 11,4/4,3 132 B3 9
5,5 11 132 B3 9 7,0/1,7 15,2/5,1 132 B3 9
7,5 14,6 132 B3 9 11/3,0 24/9,5 160 B3 12
11 20,5 132 B3 9 14/3,5 30,5/11,4 160 B3 12
1500/750 1,0/0,25 2,4/1,0 90 B3 5 20/5,5 39/16,2 180 B3 12
1500/1000 1,1/0.37 2,8/1,35 90 B3 5 28/7,0 52/16,2 180 B3 12
3000/1500 4,1/1,0 8,8/2,1 112 B3 5
7,8/2,0 16,2/4,1 132 B3 9 1120 1000 5,5 12,7 132 B3 12
7,5 15,7 160 B3 12
630 1000 0,75 2,2 90 B3 9 11 22 160 B3 12
1,1 3,15 90 B3 9 15 29.5 180 B3 12
1500 1,1 2,8 90 B3 9 1500 11 22 160 B3 12
1,5 3,5 90 B3 9 15 29,5 160 B3 12
2,2 5,5 100 B3 9 18,5 36 180 B3 12
3,0 7,1 100 B3 9 22 43 180 B3 12
1500/750 1,0/0,25 2,4/1,0 90 B3 9 30 52 200 B3 12
1,4/0,35 3,3/1,35 90 B3 9 37 68 200 B3 12
2,5/0,6 5,6/2,2 100 B3 9 1500/750 11/3,0 24/9,5 160 B3 12
1500/1000 1,1/0,37 2,8/1,35 90 B3 9 16/4,0 32,5/11,9 180 B3 12
2,2/0,75 5,3/2,3 100 B3 9 20/5,5 39/16,2 180 B3 12
3,0/1,0 6,3/3,0 112 B3 9 24/6,0 46/14,5 200 B3 12
28/7,0 52/16,2 200 B3 12
800 1000 1,5 3,9 100 B3 9 36/9,0 78/24 200 B3 12
2,2 5,4 112 B3 9
1500 4,0 8,6 112 B3 9
5,5 11,4 132 B3 9
7,5 15,4 132 B3 9
1500/750 3,8/1,0 8,1/3,4 112 B3 9
5,5/1,4 11,4/4,3 132 B3 9
7,0/1,7 15,2/5,1 132 B3 9

 Nominal current = appr. values for 400 V motors, brand EMOD.


It is important to check nominal current in case of other motor brands.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXO 300°C - 120 MIN SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 053
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Nominal Output Nominal
Size Size Type Size Size Type
speed [kW] current [A] speed [kW] current [A]
[rpm]  

400 1500 1,1 2,8 90 B3 5 1000 1000 3,0 7,4 132 B3 9


3000 1,5 3,25 90 B3 5 4,0 9,2 132 B3 9
2,2 4,6 90 B3 5 5,5 12,7 132 B3 9
3,0 6,7 100 B3 5 7,5 15,7 160 B3 9
3000/1500 1,5/0,37 3,7/1,0 90 B3 5 1500 7,5 15,4 132 B3 9
2,2/0,48 4,6/1,15 90 B3 5 11 22 160 B3 12
3,0/0,75 6,7/1,7 100 B3 5 15 29,5 160 B3 12
18,5 36 180 B3 12
500 1500 1,1 2,8 90 B3 5 22 43 180 B3 12
3000 3,0 6,7 100 B3 5 30 52 200 B3 12
4,0 8,3 112 B3 5 1500/750 5,5/1,4 11,4/4,3 132 B3 9
5,5 11 132 B3 9 7,0/1,7 15,2/5,1 132 B3 9
7,5 14,6 132 B3 9 11/3,0 24/9,5 160 B3 12
11 20,5 132 B3 9 14/3,5 30,5/11,4 160 B3 12
1500/750 1,0/2,5 2,4/1,0 90 B3 5 20/5,5 39/16,2 180 B3 12
1500/1000 1,1/0,37 2,8/1,35 90 B3 5 28/7,0 52/16,2 180 B3 12
3000/1500 4,1/1,0 8,8/2,1 112 B3 5
7,8/2,0 16,2/4,1 132 B3 9 1120 1000 5,5 12,7 132 B3 12
7,5 15,7 160 B3 12
630 1000 0,75 2,2 90 B3 9 11 22 160 B3 12
1,1 3,15 90 B3 9 15 29,5 180 B3 12
1500 1,1 2,8 90 B3 9 1500 11 22 160 B3 12
1,5 3,5 90 B3 9 15 29,5 160 B3 12
2,2 5,5 100 B3 9 18,5 36 180 B3 12
3,0 7,1 100 B3 9 22 43 180 B3 12
1500/750 1,0/0,25 2,4/1,0 90 B3 9 30 52 200 B3 12
1,4/0,35 3,3/1,35 90 B3 9 37 68 200 B3 12
2,5/0,6 5,6/2,2 100 B3 9 1500/750 11/3,0 24/9,5 160 B3 12
1500/1000 1,1/0,37 2,8/1,35 90 B3 9 16/4,0 32,5/11,9 180 B3 12
2,2/0,75 5,3/2,3 100 B3 9 20/5,5 39/16,2 180 B3 12
BVAXO

3,0/1,0 6,3/3,0 112 B3 9 24/6,0 46/14,5 200 B3 12


28/7,0 52/16,2 200 B3 12
800 1000 1,5 3,9 100 B3 9 36/9,0 78/24 200 B3 12
2,2 5,4 112 B3 9
1500 4,0 8,6 112 B3 9
5,5 11,4 132 B3 9
7,5 15,4 132 B3 9
1500/750 3,8/1,0 8,1/3,4 112 B3 9
5,5/1,4 11,4/4,3 132 B3 9
7,0/1,7 15,2/5,1 132 B3 9

 Nominal current = appr. values for 400 V motors, brand EMOD.


It is important to check nominal current in case of other motor brands.
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible. 054
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 30 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 60 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 401 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 401 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,126 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,126 m2

BVAXO 8/400/D - n = 1450 rpm


These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 8/400/D - n = 2870 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
160 630
140 560
125 500
112 450
␩=
␩=
pd
0,54

pd
100 400
0,54
45° Blade pitch angle 45° Blade pitch angle
90 355
80 315
0,52 0,53
Total pressure increase ⌬ pt [Pa] →

40°

Total pressure increase ⌬ pt [Pa] →


40°
71 280
0,50
63 0,50 250
35° 35°
56 224 0,48

50 0,47 200
45 180
25° 30° 25° 30°
1600

1800

2000

2240

2500

2800

3150

3550

4000

4500

5000

5600

6300

2800

3150

3550

4000

4500

5000

5600

6300

7100

8000

9000

10000

11200
V̇ [m3/h] → V̇ [m3/h] →
0,45

0,5

0,56

0,63

0,71

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15
V̇ [m3/s] → V̇ [m3/s] →
3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25
c [m/s] → c [m/s] →
8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

125

25

31,5

40

50

63

80

100

125

160

200

250

315

400
pd [Pa] → pd [Pa] →
Shaft power input requirement:

Shaft power input requirement:

93 107
45°
=

40° 91 45° 105


V [m3/h] · ⌬pt [Pa]

35°
V [m3/h] · ⌬pt [Pa]

Total acoustic power level


Total acoustic power level

30° 40°
␩· 1000 · 3600

89 35° 103
␩· 1000 · 3600

25° 87 30° 101


25°
85 99
83 97
81 95
·

79 93
Pw [kW] =

Pw [kW] =

Lw [dB]
77
Lw [dB]

91
75 89
73 87

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 504 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 504 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,2 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,2 m2

BVAXO 5/500/D - n = 1450 rpm


These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 5/500/D - n = 2870 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

200 710

180 630

160 560

140 500
pd

␩=
␩=
125 0,51 45° Blade pitch angle 450 0,51
0,49
pd

112 0,49 400


40°
100 355 0,48
37,5°
Total pressure increase ⌬ pt [Pa] →
Total pressure increase ⌬ pt [Pa] →

90 0,48 315
35° 32,5° Blade pitch angle
80 280
32,5° 0,44 30°
71 0,44 30° 250

63 224

56 200
25°
20° 25° 20°
4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000
2 800

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

V̇ [m3/h] → V̇ [m3/h] →
0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

V̇ [m3/s] → V̇ [m3/s] →
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

c [m/s] → c [m/s] →
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160

20

25

31,5

40

50

63

80

100

125

160

200

250

315

pd [Pa] → pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:

95 107
=
=

93 105
V [m3/h] · ⌬pt [Pa]
V [m3/h] · ⌬pt [Pa]

Total acoustic power level

Total acoustic power level

91 103
␩· 1000 · 3600
␩· 1000 · 3600

35° 40° 89 30° 101


30° 45° 87 20° 25° 32,5° 99
37,5° 85 97
25° 83 95
·
·

32,5° 81 93
Pw [kW] =
Pw [kW] =

20°
Lw [dB]

79 91
Lw [dB]

77 89
75 87

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C – 120 MIN Subsequent pitch variations are not possible. 055
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 32 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 504 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,2 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2

BVAXO 9/500/D - n = 2870 rpm


These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
180
BVAXO 9/630/D - n = 980 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

1250

1120 160

1000 140
␩=
900 125 0,62

pd
800 112 0,60
45° Blade pitch angle
␩=
710 0,47
100
pd
630 90 0,58 40°
0,46

Total pressure increase ⌬ pt [Pa] →


Total pressure increase ⌬ pt [Pa] →

560 45° Blade pitch angle 80 0,56 37,5°


0,44
500 71
0,51 35°
450 0,40
40° 63

400 37,5° 56 32,5°

355 35° 50
20° 25° 30°

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000
7 100

8 000

9000

2,8 10 000

3,15 11 200

3,55 12 500

4,0 14 000

4,5 16 000
18000

5,6 20 000

6,3 22 400

7,1 25 000

8,0 28 000

V̇ [m3/h] → V̇ [m3/h] →

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5
2,0

2,24

2,5

5,0

V̇ [m3/s] → V̇ [m3/s] →
3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14
10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

c [m/s] → c [m/s] →
63

80

100

125

160

200

250

315

400

500

630

800

1 000

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

125
pd [Pa] → pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:

115 91
=
=

113 35° 89
V [m3/h] · ⌬pt [Pa]
V [m3/h] · ⌬pt [Pa]

32,5°

Total acoustic power level


Total acoustic power level

␩· 1000 · 3600

111 87
␩· 1000 · 3600

45°
35° 109 25° 30° 85
37,5° 40°
107 83
37,5° 105 20° 81
45° 103 79
·
·

101 77
Pw [kW] =
Pw [kW] =

40°

Lw [dB]
99 75
Lw [dB]

97 73
94 71
( ) S( )

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 46 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 94 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2

400
BVAXO 9/630/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 9/630/D - n = 2880 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
1600
355 1400
315 1250
280 1120
␩= ␩ = 0,61
pd

0,61
pd

250 1000 0,51


0,59 45° Blade pitch angle
224 900
0,58
200 0,56
800
0,56
Total pressure increase ⌬ pt [Pa] →

Total pressure increase ⌬ pt [Pa] →

BVAXO

180 40° 710


0,54 37,5° Blade pitch angle
160 37,5° 630
0,54
140 35° 560 35°
0,52
125 500 32,5°
32,5°
112 450
20° 25° 30°
5600

6300

7100

8000

9000

10000

11200

12500

14000

16000

18000

20000

22400

11200

12500

14000

16000

18000

20000

22400

25000

28000

31500

35500

40000

45000

V̇ [m3/h] → V̇ [m3/h] →
1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

V̇ [m3/s] → V̇ [m3/s] →
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

c [m/s] →
10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

c [m/s] →
16

20

25

31,5

40

50

63

80

100

125

160

200

250

pd [Pa] →
63

80

100

125

160

200

250

315

400

500

630

800

1000

pd [Pa] →
Shaft power input requirement:

Shaft power input requirement:

103 118
=

101 116
V [m3/h] · ⌬pt [Pa]

V [m3/h] · ⌬pt [Pa]


Total acoustic power level

Total acoustic power level

99
␩· 1000 · 3600

␩· 1000 · 3600

114
32,5° 35° 97 112
30° 95
45° 37,5° 110
25° 40° 93 35° 108
20° 37,5° 91 32,5° 106
·

89
Pw [kW] =

104
Pw [kW] =

87
Lw [dB]

Lw [dB]

102
85 100
83 98

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible.
056
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 94 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 30 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 797 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,5 m2

BVAXO 5/630/D - n = 2880 rpm


These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
140
BVAXO 9/800/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

1250

1120 125

1000 112

900 100
␩=

pd
800 90 0,67
45° Blade pitch angle
710 80
0,64
630 ␩= 71
0,59 40°
Total pressure increase ⌬ pt [Pa] →

Total pressure increase ⌬ pt [Pa] →


pd

560 63
0,59
37,5°
500 0,48 0,58 56
0,55 35°
450 50
0,56
0,50
400 30° Blade pitch angle 45
32,5°
0,51
355 40
20° 25° 20° 25° 30°

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400
8000

9000

10000

11200

12500

14000

16000

18000

20000

22400

25000

28000

31500

V̇ [m3/h] → V̇ [m3/h] →
2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3
V̇ [m3/s] → V̇ [m3/s] →
7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5
c [m/s] → c [m/s] →
31,5

40

50

63

80

100

125

160

200

250

315

400

500

6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100
pd [Pa] → pd [Pa] →
Shaft power input requirement:

Shaft power input requirement:

112 92
=

110 40° 90
V [m3/h] · ⌬pt [Pa]

V [m3/h] · ⌬pt [Pa]


Total acoustic power level

Total acoustic power level


␩· 1000 · 3600

108 88
␩· 1000 · 3600

106 32,5° 35° 45° 86


104 30° 84
30° 25°
102 82
20° 25° 100 20° 37,5° 80
·

98 78
Pw [kW] =

Pw [kW] =

96 76
Lw [dB]

Lw [dB]
94 74
92 72
Ai fl di i D( i l ) Pl i i f Ai fl di i S( i i l ) Vl dd d d fi

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 39 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 60 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 797 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 797 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,5 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,5 m2

BVAXO 9/800/D - n = 980 rpm


These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
500
BVAXO 9/800/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

250

224 450

200 400
␩=
180 355
pd

0,68
pd

␩=
315 45° Blade pitch angle
160 0,67
45° Blade pitch angle
0,65
0,64
140 280
40°
0,63
125 250
40° 0,60
Total pressure increase ⌬ pt [Pa] →

37,5°
Total pressure increase ⌬ pt [Pa] →

0,59 224
112
37,5° 200 35°
100 0,56
0,56
90 35°
180
32,5°
80 160
0,50 32,5° 0,52
71 140 30°
20° 25° 30° 20° 25°
11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000
7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

V̇ [m3/h] → V̇ [m3/h] →
3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5
2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

V̇ [m3/s] → V̇ [m3/s] →
6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

c [m/s] →
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

c [m/s] →
25

31,5

40

50

63

80

100

125

160

200

250

315

400

pd [Pa] →
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160

pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:

40° 96 106
=
=

94 104
V [m3/h] · ⌬pt [Pa]

37,5°
V [m3/h] · ⌬pt [Pa]

45°
Total acoustic power level

32,5°
Total acoustic power level

102
␩· 1000 · 3600

92
␩· 1000 · 3600

32,5° 45°
30° 90 100
25° 37,5° 88 25° 40° 98
35° 86 96
20° 20° 35° 94
84
·
·

30° 92
Pw [kW] =

82
Pw [kW] =

90
Lw [dB]
Lw [dB]

80
78 88
76 86
Ai fl di i D( i l ) Pl i i f Ai fl di i S( i i l ) Vl dd d d fi

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible. 057
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 51 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2

125
BVAXO 9/1000/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

315
BVAXO 9/1000/D - n = 980 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

112 280
␩=
0,57
100 250

pd
0,56 ␩=
90 224 0,61
50° Blade pitch angle
80 0,54 200 0,60

71 180
45°
0,58
63 0,52 160
0,56
Total pressure increase ⌬ pt [Pa] →

Total pressure increase ⌬ pt [Pa] →


56 140
pd

50 35° Blade pitch angle 125 40°


0,54
0,50
45 112
0,48 37,5°
40 32,5° 100
35,5 90 35°
25° 30° 25° 30° 32,5°

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000
8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

V̇ [m3/h] → V̇ [m3/h] →
2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14
V̇ [m3/s] → V̇ [m3/s] →
2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18
c [m/s] → c [m/s] →
5,0

6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

80

12,5

16

20

25

31,5

40

50

63

80

100

125

160

200
pd [Pa] → pd [Pa] →
Shaft power input requirement:

Shaft power input requirement:

90 106
=

25° 88 104
V [m3/h] · ⌬pt [Pa]

V [m3/h] · ⌬pt [Pa]


Total acoustic power level

Total acoustic power level


35° 86 102
␩· 1000 · 3600

␩· 1000 · 3600

32,5° 84 45° 100


30° 82 98
37,5°
80 50° 96
78 94
40°
·

25°
·

76 92
Pw [kW] =

Pw [kW] =

74 30° 35° 90
Lw [dB]

Lw [dB]
72 32,5° 88
70 86

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2

500
BVAXO 9/1000/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 12/1000/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

224
450 200
400 ␩= 180
0,58
355 160
pd

315 140
␩= 50° Blade pitch angle
280 125 0,58
0,54 0,44
250 112 0,56 45°
0,52
Total pressure increase ⌬ pt [Pa] →
Total pressure increase ⌬ pt [Pa] →

224
BVAXO

100
pd

0,52
200 35° Blade pitch angle 90
40°
180 80
0,48
160 37,5°
32,5° 71
140 63
25° 30° 35°
14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

V̇ [m3/h] → V̇ [m3/h] →
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

V̇ [m3/s] → V̇ [m3/s] →
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

c [m/s] →
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

c [m/s] →
16

20

25

31,5

40

50

63

80

100

125

160

200

250

pd [Pa] →
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160

pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:

112 100
=
=

110 98
V [m3/h] · ⌬pt [Pa]
V [m3/h] · ⌬pt [Pa]

Total acoustic power level


Total acoustic power level

108 35°
␩· 1000 · 3600
␩· 1000 · 3600

96
106 37,5° 94
104 50° 92
102 45° 90
35° 100 40°
32,5° 88
·
·

30° 98 86
Pw [kW] =
Pw [kW] =

96
Lw [dB]

84
Lw [dB]

94 82
25° 92 80
* Ai fl di i D( i l ) Pl i i f Ai fl di i S( i i l ) Vl dd d d fi ( ) S( )

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible. 058
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 42 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1124 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 1,0 m2

500
BVAXO 12/1000/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 12/1120/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.

224
450 200
400 ␩= 180

pd
0,58
␩=
355 50° Blade pitch angle
160 0,56

315 140
280 125 0,53
45°
0,54
250 112 0,51
0,52
Total pressure increase ⌬ pt [Pa] →

Total pressure increase ⌬ pt [Pa] →


224 100
pd

0,49
40°
200 35° Blade pitch angle 90
180 80
0,48 0,47 37,5°
160 71
32,5°
140 63
35°
25° 30° 30° 32,5°
14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000
V̇ [m3/h] → V̇ [m3/h] →
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18
V̇ [m3/s] → V̇ [m3/s] →
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

c [m/s] →
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18
c [m/s] →
16

20

25

31,5

40

50

63

80

100

125

160

200

250

pd [Pa] →
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200
pd [Pa] →
Shaft power input requirement:

Shaft power input requirement:

112 105
=

110 103
V [m3/h] · ⌬pt [Pa]

V [m3/h] · ⌬pt [Pa]


Total acoustic power level

Total acoustic power level


108 101
␩· 1000 · 3600

␩· 1000 · 3600

50°
106 40° 99
104 97
102 35°
35° 30° 95
100 45°
32,5° 93
·

30° 98 91
Pw [kW] =

Pw [kW] =

96 37,5° 89
Lw [dB]

Lw [dB]
94 87
25° 92 32,5°
85

V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 57 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 84 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1124 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1124 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 1,0 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 1,0 m2

BVAXO 12/1120/D - n = 980 rpm


These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 12/1120/D - n = 1440 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
400 800

355 710
pd

315 630
␩= 50°
pd

280 560 0,55 Blade pitch


angle
␩= 50°
250 0,58 Blade pitch 500 0,52
angle 0,54
224 450 45°
45°
0,56
200 400 0,50
Total pressure increase ⌬ pt [Pa] →

Total pressure increase ⌬ pt [Pa] →

180 355
0,46 40°
160 0,53 40° 315 0,48
0,50
140 280 37,5°
37,5°
125 250
0,44
112 224 35°
0,45 35°
25° 30° 32,5° 25° 30° 32,5°
25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000
16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

V̇ [m3/h] → V̇ [m3/h] →
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

V̇ [m3/s] → V̇ [m3/s] →
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

c [m/s] → c [m/s] →
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200

31,5

40

50

63

80

100

125

160

200

250

315

400

500

pd [Pa] → pd [Pa] →
Shaft power input requirement:

Shaft power input requirement:

106 117
=

45° 50° 104 45° 115


V [m3/h] · ⌬pt [Pa]

V [m3/h] · ⌬pt [Pa]


Total acoustic power level

Total acoustic power level

102 37,5° 50° 113


␩· 1000 · 3600

␩· 1000 · 3600

37,5°
100 32,5° 111
32,5° 98 109
25° 96 25° 40° 107
40°
35° 94 105
·

92 103
Pw [kW] =

35°
Pw [kW] =

30° 30°
90 101
Lw [dB]

Lw [dB]

88 99
86 97

* rounded to standard values For maximum motor sizes please see dimension pages
– 059 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Axial Smoke Exhaust Fan – BVAXO Series, Type M-D


for the extraction of smoke fumes of 200°C/120 min. or
300°C/120 min. respectively
tested as per EN 12101-T3 (Munich Technical University)
approval no. Z-78.1-41
Airflow direction: motor in outlet
Direct-drive type
Appropriate for installation in- and outside of fire-zone.
Consisting of:
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3
hub and blades made of cast-aluminium, non-adjustable
directly mounted on shaft end of special motor placed within
the smoke fume flow,
type B3, protection classe IP 54, wired to exterior
temperature-resistant terminal box

Surface protection:
Polyester powder coating, colour: RAL 7030
or as of nominal size 1120: with full paint finish, colour: RAL7030
or Hot-dip galvanized
Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)

Specifications:
Volume flow m3/h
Temperature / humidity 0
C/ %R.H.
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total sound power level Lw dB
Efficiency %
Power input requirement kW
Three-phase motor:
BVAXO

single-speed
or Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Current consumption A
Voltage V
Frequency Hz
Protection Class (IP)
Type B/V
Size

Weight: Fan incl. accessories kg


Manufacturer: TLT-Turbo GmbH

Carryover
Type: BVAXO..........M-D
– 060 –
Unit price Total
Item
Qty. Description
No.
2 2

Options:

• Galvanised fan
• Fan with special coating
• Extension casing without inspection hatch
• Inspection hatch
• Bellmouth inlet with flange
• Wire guard on bellmouth side
• Wire guard on extension casing (motor side)
• Flexible connector, inlet side*
• Flexible connector, outlet side*
• Matching flange inlet side*
• Matching flange outlet side*
• Angular wall ring with brackets*
• Set of mounting feet (2 pcs.)*
• Set of spring-type antivibration mounts*
• Brackets for vertical fan installation
• Diffuser without interior core*
• exhaust pipe with protection grid*
• duct with self-activating damper*

Note:

Please see our Installation, Operating and Maintenance


Instructions that are available on request.

* Loosely supplied
AXIAL SMOKE EXHAUST FANS
SERIES BVAXN 12/56
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C - 120 MIN 061
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Important! This fan series is available with the motor outputs


Mmax. stated in our price lists only.
X
øk

zxd

i.d.
L øD

No cooling-fan required

Weight
Size1) i.d. (kg) Motor size - Type
Size without Flange dia. Ø 2) - Shaft dia. Ø
motor

BVAXN 12/56

930 200 - B 5 225 - B 5


350 - 55 350 - 60

960 200 - B 5 225 - B 5


350 - 55 450 - 60
160 - B5 200 - B 5 225 - B 5 250 - B 5 280 - B 5
1124 1214 450 170 1200 120 350 - 42 400 - 55 450 - 60 550 - 65 550 - 75
200 - B 5 225 - B 5 250 - B 5 280 - B 5
1261 1311 1351 500 185 1230 145 400 - 55 450 - 60 550 - 65 550 - 75

3)
200 - B 5 225 - B 5 250 - B 5 280 75 315 80
400 - 55 450 - 60 550 - 65 B3/V1/V3 B3/V1/V3
200 - B 5 225 - B 5
3) 400 - 55 450 - 60
200 - B 5 280 75 315 80
550 - 65 B3/V1/V3 B3/V1/V3

For vibration-damped installation an Extension Special flanges may be = For vibration-damped installation Dimensions mm
Extension casing may be required with fans up needed with certain sizes. two extension casings should be
to size 1250 provided.
3) with steel impeller 8/56
Dimensional and design
changes reserved.

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
AXIAL SMOKE EXHAUST FANS
SERIES BVAXN 12/56
MAIN DIMENSIONS ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 062
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Wire Guard Bell mouth Mounting feet Mounting feet for fans with extension casing or
Inlet side inlet R1 types
i.d1

Flexible connector Angular Matching flange Extension casing Spring-type


wall ring AV-mounts 2)
i.d2

i.d2
i.d2

length (same dimensions as


installation fan type M-D)

Size ØD1 i.d1 c H a a1 a2 a3 b b1 z x d3 i.d2 Øk ØD z x d1) e f

355 501 362 69 270 221 191 386 356 330 270 5 x 9,5 360 395 425 8 x 9,5 80 50
400 562 403 78 300 248 218 436 406 370 300 5 x 9,5 403 438 468 12 x 9,5 80 50
450 631 424 87 335 260 230 460 430 410 330 5 x 9,5 452 487 517 12 x 9,5 80 50
500 708 509 98 375 285 255 510 480 460 380 5 x 9,5 506 541 571 12 x 9,5 80 50
560 794 571 109 420 317 277 559 519 510 430 5 x 11,5 568 605 643 16 x 11,5 100 70
630 875 640 95 470 361 321 647 607 550 470 5 x 11,5 637 674 712 16 x 11,5 100 70
710 972 717 103 525 380 340 685 645 620 530 5 x 11,5 714 751 785 16 x 11,5 100 70
800 1081 801 115 585 425 385 775 735 730 640 5 x 11,5 800 837 875 24 x 11,5 100 70
900 1214 898 130 655 452 412 825 781 730 640 5 x 11,5 897 934 972 24 x 11,5 100 70
1000 1351 1009 145 730 512 466 927 881 830 740 5 x 14 1006 1043 1081 24 x 11,5 100 70
1120 1470 1130 160 760 547 501 997 951 920 820 5 x 14 1133 1174 1214 24 x 11,5 110 90
1250 1677 1263 185 855 597 551 1097 1051 1030 930 5 x 14 1270 1311 1351 24 x 11,5 110 90
a = Casing length + 87
1400 1870 1417 210 930 a1 = –”– +41 1140 1040 5 x 14 1424 1465 1505 24 x 11,5 130 100
1600 2087 1587 210 1020 a = Casing length + 92 1350 1230 5 x 18 1596 1637 1677 32 x 11,5 130 100
1) Connecting dimensions in 2) Height under load will be * all accessories, except duct Dimensions in mm
accordance with DIN 24 154 – communicated upon specification feet and duct extension, are
Series 3 (value is calculated individually for packed separately
Dimensional and design
each purchase order).
changes reserved.
AXIAL SMOKE EXHAUST FANS
SERIES BVAXN 12/56
MAIN DIMENSIONS ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300/400°C – 120 MIN 063
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Brackets for vertical installation Diffuser with interior core

i.d.

i.d2
1

welded

Duct with self-activating damper Outlet cone with wire guard


C G L4 L2

Øk

wire guard
zxd L3

Size A  A1  b d1 i.d. Øk ØD z x d1) i.d2 Ø d3 Ø k2 Ø D2 z x d2 L1 L2 L3 L4 C G


355 511 559 68 12 – 395 – 8 x 9,5 – – – – – – 280 80 165 250 40

400 554 602 68 12 – 438 – 12 x 9,5 – – – – – – 280 60 188 280 40

450 603 651 68 12 – 487 – 12 x 9,5 – – – – – – 290 70 200 350 200 BVAXN 12/56
500 657 705 68 12 504 541 571 12 x 9,5 634 282 674 712 16 x 11,5 600 280 60 225 390 200

560 783 831 90 14 565 605 643 16 x 11,5 711 315 751 789 16 x 11,5 670 330 70 242 430 200

630 852 900 90 14 634 674 712 16 x 11,5 797 355 837 875 24 x 11,5 750 330 70 286 465 200

710 929 977 90 14 711 751 789 16 x 11,5 894 397 934 972 24 x 11,5 850 350 70 305 505 200

800 1015 1063 90 14 797 837 875 24 x 11,5 1003 446 1043 1081 24 x 11,5 950 520 200 350 550 200

900 1112 1160 90 14 894 934 972 24 x 11,5 1124 502 1174 1254 24 x 11,5 1060 585 225 373 620 200

1000 1221 1269 90 14 1003 1043 1081 24 x 11,5 1261 562 1311 1391 24 x 11,5 1200 640 240 415 690 200

1120 1374 1434 100 18 1124 1174 1254 24 x 11,5 1415 630 1465 1545 24 x 11,5 1340 730 250 450 820 300

1250 1511 1571 100 18 1261 1311 1391 24 x 11,5 1587 710 1637 1717 32 x 11,5 1510 810 250 500 950 300

1400 1665 1725 100 18 1415 1465 1545 24 x 11,5 1780 789 1830 1910 32 x 11,5 1690
on request
1600 1837 1897 100 18 1587 1637 1717 32 x 11,5 1997 888 2047 2167 32 x 11,5 1900

1) Fitting dimensions to Dimensions in mm


DIN 24 154 – series 3
Dimensional and design changes
reserved.
AXIAL SMOKE EXHAUST FANS
ACCESSORIES
ROUND SILENCERS – TSR
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 064
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

As a supplement to our BVAXN 12/56


series of axial smoke exhaust fans
we can supply specially developed
round silencers available in 12 sizes.
These units substantially reduce the
sound level.
They are easily fitted on the fan inlet
or outlet side, without any additional
intermediate elements.
The silencer housing consists of
Sendzimir galvanized sheet steel.
Mounting nuts are provided internal-
ly on the connecting face sides (hole
pattern as per DIN 24154-Series 3).
The interspace between the exterior
barrel and the interior sleeve (made
of galvanized perforated sheet metal)
as well as the interior core are filled
with non-combustible acoustic dam-
ping material.

Insertion attenuation per silenzer


Nomi- Insertion attenuation in dB Nominal Weight
nal Ø d i.L. ØD Øk Ø d1 L z x ø d2
For higher attenuations several silencers of diameter [kg]
dia. identical diameter may be arranged in series.

Octave center frequency fo [Hz]


355 359 525 395 200 930 8xM8 39
63 125 250 500 1000 2000 4000 8000
400 401 570 438 224 930 12 x M 8 50
355 7 13 17 22 24 30 23 19

400 6 12 16 21 23 29 22 18
450 450 620 487 250 930 12 x M 8 56

450 6 11 15 19 21 26 20 16 500 504 675 541 280 930 12 x M 8 60


500 5 10 14 17 19 23 18 14 560 565 735 605 315 930 16 x M 8 68
560 4 9 13 16 18 22 17 13 630 634 885 674 355 930 16 x M 8 76
630 3 8 12 15 17 20 16 12
710 711 960 751 400 1430 16 x M 8 120
710 6 11 16 19 21 20 17 13
800 797 1050 837 450 1430 24 x M 8 137
800 5 10 14 17 19 18 16 12
900 894 1145 934 500 1430 24 x M 8 153
900 4 9 13 16 18 16 13 9

1000 3 8 12 15 17 14 12 8
1000 1003 1255 1043 560 1430 24 x M 8 167

1120 4 8 13 16 18 15 13 9 1120 1124 1375 1174 630 1430 24 x M 8 207

1250 4 9 13 17 18 16 13 9 1250 1261 1515 1311 710 1430 24 x M 8 254

224
180
140
static pressure loss ⌬ ps [Pa] ➞

5
35

112
ia

00

50
0

0
0

20
0

56

63

71

80

90
45
40

50
ld

90
10

12
11
ina

Ø
Ø
Ø

Ø
Ø

71
m

This diagram shows the


no

56 static pressure loss


caused by insertion of a
(per silencer)

45 silencer into a matching


35,5 duct of the diameter
shown.
28
22,4
2000

2500

3150

4000

5000

6300

8000

10000

12500

16000

20000

25000

31500

40000

50000

63000

80000

100000

125000

Volume flow V̇ [m3/h] ➞

Dimensional and design changes reserved.


ACOUSTIC - AND THERMAL INSULATION
FOR BVAXO + BVAXN

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 065


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Description:
shell-design, easy dismanteling, re-
usable. For acoustic insulation and/or
reduction of thermal emission from
the fan casing.
The design of this insulation - compa-
red to some ohter types - allows a
more space saving installation with
improved accessibility as well as con-
siderably easier testing and mainten-
ance of the fan.
The Insulation consists of:
A certain number of shells acc. to fan
length, split into upper and lower
shell, made of galvanized steel sheet
with adjustable also galvanized ten-
sioners. Galvanized steel sheets for
connecting the shells in the vicinity of
the fan’s mounting feet as well as in-
sulated connections to flexible
connectors or ducts. Axial Fan BVZAXN 12/56/1000 with acoustic insulation
Insulating material made of mineral
wool with wire gauze on one side,
thickness 80 mm and 120 mm respet-
cively, not inflammable class A1 as
per DIN 4102 T4, specific density 60-
80 kg/m3. These mats are fixed to the
shells.

Total insulation value


Axial Fan with insulated casing
[A-weighted]
Calculation of fresh air needed for installation room

approximative calculation af the Thermal emission of insulated axial fans


at flue gas temperatures of 200, 300, 400 and 600°C
BVAXN 12/56
A-weighted acoustic power, emitted
from the insulated fan casing
1000
Room temperature: Troom = const. 40°C Sizes 315 to 560 insulation thickness 80 mm
Sizes 630 to 1600 thickness 120 mm 600°C
Fresh air temp.: Tfresh air = const. 20°C
LWAcasing = LWvent. – Dechart 900
Insulation surface: Tmax = 180°C
Thermal emission Q (W/m)

L = fan length (m)


800 V· = fresh air volume flow

· Q·L
·
700 V· = [m3/h]
Insulation value [De] 0,336 · (Troom - Tfresh air)
Insulation value [De] 600 400°C
dB (A) weighted
500
300°C
fD [Hz] 500 250 125 400
size 300 600°C 200°C
35 35 36
315-560
size 200 400°C
37 38 37
630-1600 100 300°C
200°C
0
315

355

400

450

500

560

630

710

800

900

1000

1120

1250

1400

1600

(please ask for exact value of insula-


Fan size (nominal-Ø)
tion within the octave band)
ACOUSTIC AND THERMAL INSULATION
TYPES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 066
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Examples for horizontal installation


Type A Type B Type C
L2 L3 L3
Insulation

Type D
D2
L4 Insulation

for dimensions please


see page 067

In case of horizontal outdoor installation a canope is to be erected covering


complete insulation (available upon request).

Examples for vertical installation

Size L3 A2 A3 b d
L3
355 495 631 679 68 12

400 564 674 722 68 12

450 600 723 771 68 12

500 675 777 825 68 12

560 726 903 951 90 14


d
630 858 1014 1066 90 14
Insulation
710 915 1091 1143 90 14

800 1050 1177 1229 90 14

900 1119 1274 1326 90 14


b

1000 1245 1383 1435 90 14 This insulation should not be used


for vertical outdoor installation.
1120 1350 1504 1564 100 18

1250 1500 1641 1701 100 18


A2
A3 dimensions in mm
ACOUSTIC AND THERMAL INSULATION
MAIN DIMENSIONS
CONNECTION DETAILS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 067
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Size D2 L2 L3 L4 Size D2 L2 L3 L4

355 525 330 495 660 710 960 610 915 1220

400 570 376 564 752 800 1050 700 1050 1400

450 620 400 600 800 900 1145 746 1119 1492

500 675 450 675 900 1000 1255 830 1245 1660

560 735 484 726 968 1120 1375 900 1350 1800

630 885 572 858 1144 1250 1515 1000 1500 2000

Fan - Flexible connector - angular duct


Tensioner
Connecting
Insulation loosely
piece
supplied
Adhesive tape
230
Angular
Flexible sleeve duct
(customer-
supplied)

Impeller of
axial fan

Flexible
Connector

200

Fan - Flexible Connector - Duct


BVAXN 12/56

Connecting piece
230 Tensioner Insulated duct
Flexible sleeve Adhesive tape (customer-
supplied)

Impeller of
axial fan
Insulation
(loosley
supplied)
Flexible
Connector

200
AXIAL SMOKE EXHAUST FANS
BVAXN 12/56 SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 068
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Acoustic level Starting from this value, the A-weigh- ning, respectively. The values given
ted acoustic power level LWA and the were taken from measurements as
relative acoustic power level LWrel. per EN 25136 (formerly DIN 45 635,
The total acoustic power level Part 9) duct testing method.
can be determined using the tables
LW.Vent. (in dB) of an axial smoke ex- below. These values are available as
haust fan can be obtained directly the acoustic power emitted into the
from the characteristic data sheets for duct and as the acoustic power emit-
each operating point. ted from the fan inlet or outlet ope-

1. Acousting power level emitted into the duct Axial Smoke Exhaust Fan BVAXN
The level of acoustic power an axial smoke exhaust fan
Portion 1.2 at mid-octave frequency [Hz]
emits into the ducting is used for calculating the sound power z·n
fD = –––– Portion 1.1
60
characteristics of downstream systems, e.g., silencers. 63 125 250 500 1000 2000 4000 8000
The levels are calculated as follows:
500 2 13 10 8 6 6 12 15 16
Lwvent. [dB] = total acoustic power emitted by the fan, 250 5 10 8 5 5 11 14 16 18
(please see respective characteristic curve
sheets) 125 7 7 5 5 11 14 16 18 22

63 10 4 4 10 13 15 17 21 25
LwA vent. [dB] = A-weighted acoustic power level, according
to the equation 31,5 11 3 9 12 13 15 20 24 28

LwA vent. = Lwvent. – portion 1.1 [dB]


fD =
Portion 2.2 at mid-octave frequency [Hz]
Lwrel vent. [dB] = relative acoustic power level as expressed Size* z·n
Portion
2.1
by the equation 60 63 125 250 500 1000 2000 4000 8000
315 500 3 25 18 12 7 6 12 15 16
Lwrel vent. = Lwvent. – portion 1.2 [dB] 250 6 23 16 9 7 12 14 16 18
125 8 20 13 9 12 14 16 18 22
400 500 3 23 17 11 6 6 12 15 16
250 5 21 14 9 6 11 14 16 18
125 8 18 11 8 12 14 16 18 22
2. Acoustic power emitted from the fan inlet or outlet 63 10 15 11 13 14 15 17 21 25
opening 500 500 2 22 15 10 6 6 12 15 16
250 5 20 13 8 6 11 14 16 18
To determine the sound levels at a given installation site, 125 8 17 10 7 11 14 16 18 22
it is usually necessary to know the level of acoustic power 63 10 14 9 12 13 15 17 21 25
630 500 2 21 14 9 6 6 12 15 16
emitted from the fan’s inlet or outlet opening. The adjacent 250 5 18 12 7 6 11 14 16 18
tables are based on the outlet reflection pattern assumed 125 8 15 9 6 11 14 16 18 22
in VDI 2081, Case 2. 63 10 12 8 11 13 15 17 21 25
800 500 2 19 13 9 6 6 12 15 16
LwA op. [dB] = A-weighted level of acoustic power emitted from 250 5 17 11 6 5 11 14 16 18
125 7 14 8 6 11 14 16 18 22
the fan’s opening, expressed by the equation 63 9 11 7 11 13 15 17 21 25
LwA op. = Lwvent. – portion 2.1 [dB] 1000 250 5 15 10 6 5 11 14 16 18
125 7 12 7 5 11 14 16 18 22
Lwrel op. = relative level of acoustic power emitted from the 63 9 9 6 10 13 15 17 21 25
1250 250 5 14 9 6 5 11 14 16 18
fan’s opening, expressed by the equation 125 7 11 6 5 11 14 16 18 22
Lwrel op. = Lwvent. – portion 2.2 [dB] 63 9 9 5 10 13 15 17 21 25
*Intermediate values to be obtained by interpolation.

Blade frequency of the fan ist calculated from the number of bla-
des z and the fan speed n [rpm].
z · n [s-1]
fD = ––––––
60

Lwvent.
LwAvent.
Amount linear-level

Lwrel.vent.
Amount A

fD Note:
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above
Hz 63 125 250 500 1000 2000 4000 8000 spreadsheets.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 200°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 069
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

355 1500 1,1 2,8 90 B14 160 500 1000/500 0,48/0,08 1,6/0,58 90 B5 200
3000 1,5 3,25 90 B14 160 1500/750 1,0/0,25 2,4/1,0 90 B5 200
2,2 4,6 90 B14 160 1,4/0,35 3,3/1,35 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B14 160 1500/1000 1,1/0,37 2,8/1,35 90 B5 200
3000/1500 1,5/0,37 3,7/1,0 90 B14 160 1,6/0,6 3,9/1,8 100 B5 250
3000/1500 6,0/1,5 13,3/3,2 132 B5 250
400 1500 1,1 2,8 90 B5 200 7,8/2,0 16,2/4,1 132 B5 250
3000 1,5 3,25 90 B5 200
2,2 4,6 90 B5 200 560 1000 0,75 2,2 90 B5 200
3,0 6,7 100 B14 200 1500 1,1 2,8 90 B5 200
4,0 8,3 112 B14 200 1,5 3,5 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B5 200 2,2 5,5 100 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B5 200 3,0 7,1 100 B5 250
2,2/0,48 4,6/1,15 90 B5 200 1000/500 0,8/0,15 2,3/0,9 90 B5 200
3,0/0,75 6,7/1,7 100 B14 200 1500/750 1,4/0,35 3,3/1,35 90 B5 200
4,1/1,0 8,8/2,1 112 B14 200 2,5/0,6 5,6/2,2 100 B5 250
3,8/1,0 8,1/3,4 112 B5 250
450 1500 1,1 2,8 90 B5 200 1500/1000 1,1/0,37 2,8/1,35 90 B5 200
3000 3,0 6,7 100 B14 200 1,6/0,6 3,9/1,8 100 B5 250
4,0 8,3 112 B14 200 3,0/1,0 6,3/3,0 112 B5 250
5,5 11 112 B14 200
7,5 14,6 112 B14 200 630 750 0,55 1,8 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B5 200 1000 0,75 2,2 90 B5 200
1500/1000 1,1/0,37 2,8/1,35 90 B5 200 1,1 3,15 90 B5 200
3000/1500 3,0/0,75 6,7/1,7 100 B14 200 1,5 3,9 100 B5 250
4,1/1,0 8,8/2,1 112 B14 200 1500 1,5 3,5 90 B5 200
2,2 5,5 100 B5 250
500 1500 1,1 2,8 90 B5 200 3,0 7,1 100 B5 250
1,5 3,5 90 B5 200 4,0 8,6 112 B5 250 BVAXN 12/56
3000 4,0 8,3 112 B5 250 5,5 11,4 132 B5 250
5,5 11 132 B5 250 1000/500 0,8/0,15 2,3/0,9 90 B5 200
7,5 14,6 132 B5 250 1,2/0,22 3,1/1,15 100 B5 250
11 20,5 132 B5 250 1500/750 2,5/0,6 5,6/2,2 100 B5 250
3,8/1,0 8,1/3,4 112 B5 250
5,5/1,4 11,4/4,3 132 B5 250
1500/1000 2,2/0,75 5,3/2,3 100 B5 250
3,0/1,0 6,3/3,0 112 B5 250
6,0/2,0 12,5/5,4 132 B5 250

 Nominal current = appr. values for 400 V motors, brand EMOD.


It is important to check nominal current in case of other motor brands.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 200°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 070
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

710 750 0,75 2,2 100 B5 250 800 1500/1000 6,0/2,0 12,5/5,4 132 B5 250
1,1 3,15 100 B5 250 8,5/3,0 17,9/17,6 160 B5 350
1000 1,1 3,15 90 B5 200 12/3,50 24/9,5 160 B5 350
1,5 3,9 100 B5 250 14/4,8 30/12 180 B5 350
2,2 5,4 112 B5 250 18/16,0 36/14 180 B5 350
3,0 7,4 132 B5 250
1500 3,0 7,1 100 B5 250 900 750 1,1 3,15 100 B5 250
4,0 8,6 112 B5 250 1,5 5,15 112 B5 250
5,5 11,4 132 B5 250 2,2 5,4 132 B5 250
7,5 15,4 132 B5 250 3,0 7,6 132 B5 250
11 22 160 B5 350 4,0 9,3 160 B5 350
1000/500 1,2/0,22 3,1/1,15 100 B5 250 1000 3,0 7,4 132 B5 250
1,85/0,33 4,6/1,6 112 B5 250 4,0 9,2 132 B5 250
3,3/0,75 9,3/3,6 132 B5 250 5,5 12,7 132 B5 250
1500/750 3,8/1,0 8,1/3,4 112 B5 250 7,5 15,7 160 B5 350
5,5/1.4 11,4/4,3 132 B5 250 11 22 160 B5 350
7,0/1,7 15,2/5,1 132 B5 250 1500 11 22 160 B5 350
11/3,0 24/9,5 160 B5 350 15 29,5 160 B5 350
1500/1000 4,5/1,5 9,5/3,8 132 B5 250 18,5 36 180 B5 350
6,0/2,0 12,5/5,4 132 B5 250 22 43 180 B5 350
8,5/3,0 17,9/7,6 160 B5 350 30 52 200 B5 350
12/3,5 24/9,5 160 B5 350 1000/500 3,3/0,75 9,3/3,6 132 B5 250
4,4/1,1 11/4,4 132 B5 250
800 750 1,1 3,15 100 B5 250 6,3/1,5 15,7/5,4 160 B5 350
1,5 5,15 112 B5 250 8,8/2,2 20,5/7,0 160 B5 350
2,2 5,4 132 B5 250 1500/750 11/3,0 24/9,5 160 B5 350
1000 2,2 5,4 112 B5 250 14/3,5 30,5/11,4 160 B5 350
3,0 7,4 132 B5 250 16/4,0 32,5/11,9 180 B5 350
4,0 9,2 132 B5 250 20/5,5 39/16,2 180 B5 350
5,5 12,7 132 B5 250 28/7,0 52/16,2 200 B5 350
1500 5,5 11,4 132 B5 250 1500/1000 12/3,5 24/9,5 160 B5 350
7,5 15,4 132 B5 250 14/4,8 30/12 180 B5 350
11 22 160 B5 350 18/6,0 36/14 180 B5 350
15 29,5 160 B5 350 20/7,0 41/16,2 200 B5 350
18,5 36 180 B5 350 25/9,0 47/18,5 200 B5 350
1000/500 2,6/0,5 7,1/2,8 132 B5 250 31/10 60/21,5 225 B5 350
3,3/0,75 9,3/3,6 132 B5 250
4,4/1,0 11/4,40 132 B5 250
1500/750 5,5/1,4 11,4/4,3 132 B5 250
7,0/1,7 15,2/5,1 132 B5 250
11/3,0 24/9,5 160 B5 350
14/3,5 30,5/11,4 160 B5 350
16/4,0 32,5/11,9 180 B5 350

 Nominal current = appr. values for 400 V motors, brand EMOD.


It is important to check nominal current in case of other motor brands.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 200°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 071
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

1000 750 2,2 5,4 132 B5 250 1120 1000/500 8,8/2,2 20,5/7,0 160 B5 350
3,0 7,6 132 B5 250 12,5/3,0 32,5/11 180 B5 350
4,0 9,3 160 B5 350 15,5/3,3 34/11 200 B5 400
5,5 11,4 160 B5 350 18,5/4,4 40/13,3 200 B5 400
7,5 16,1 160 B5 350 22/5,5 44,5/16 225 B5 450
1000 5,5 12,7 132 B5 350 27/6,6 52/20 225 B5 450
7,5 15,7 160 B5 350
11 22 160 B5 350 1250 750 5,5 11,4 160 B5 350
15 29,5 180 B5 350 7,5 16,1 160 B5 350
1500 15 29,5 160 B5 350 11 23,5 180 B5 350
18,5 36 180 B5 350 15 31 200 B5 400
22 43 180 B5 350 18,5 37 225 B5 450
30 52 200 B5 350 22 44,5 225 B5 450
37 66 225 B5 450 1000 15 29,5 180 B5 350
45 82 225 B5 450 20 40 200 B5 400
1000/500 4,4/1,0 11/4,4 132 B5 250 22 43 200 B5 400
6,3/1,5 15,7/5,4 160 B5 350 30 57 225 B5 450
8,8/2,2 20,5/7,0 160 B5 350 37 67 225 B5 450
12,5/3,0 32,5/11 180 B5 350 1000/500 15,5/3,0 34/11,0 200 B5 400
22/5,5 44,5/16 225 B5 450 18,5/4,4 40/13,3 200 B5 400
1500/750 16/4,0 32,5/11,9 180 B5 350 22/5,5 44,5/16 225 B5 450
20/5,5 39/16,2 180 B5 350 27/6,6 52/20 225 B5 450
28/7,0 52/16,2 200 B5 350
32/8,0 60/19 225 B5 450 1400 750 11 23,5 180 B5 350
37/10 69/24,5 225 B5 450 15 31 200 B5 450
1500/1000 18/6,0 36/14 180 B5 350 18,5 37 225 B5 450
20/7,0 41/16,2 200 B5 350 22 44,5 225 B5 450
25/9,0 47/18,5 200 B5 350 1000 30 57 225 B5 450
31/10 60/21,5 225 B5 450 37 67 225 B5 450 BVAXN 12/56
1000/500 27/6,6 52/20 225 B5 450
1120 750 4,0 9,3 160 B5 350
5,5 11,4 160 B5 350 1600 750 22 44,5 225 B5 450
7,5 16,1 160 B5 350
11 23,5 180 B5 350
15 31 200 B5 400
1000 7,5 15,7 160 B5 350
11 22 160 B5 350
15 29,5 180 B5 350
20 40 200 B5 400
22 43 200 B5 400
30 57 225 B5 450

 Nominal current = appr. values for 400 V motors, brand EMOD.


It is important to check nominal current in case of other motor brands.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 072
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

355 1500 1,1 2,8 90 B14 160 560 1000 0,75 2,2 90 B5 200
3000 1,5 3,25 90 B14 160 1500 1,1 2,8 90 B5 200
2,2 4,6 90 B14 160 1,5 3,5 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B14 160 2,2 5,5 100 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B14 160 3,0 7,1 100 B5 250
1000/500 0,8/0,15 2,3/0,9 90 B5 200
400 1500 1,1 2,8 90 B5 200 1500/750 1,4/0,35 3,3/1,35 90 B5 200
3000 1,5 3,25 90 B5 200 2,5/0,65 5,6/2,2 100 B5 250
2,2 4,6 90 B5 200 3,8/1,0 8,1/3,4 112 B5 250
3,0 6,7 100 B14 200 1500/1000 1,1/0,37 2,8/1,35 90 B5 200
4,0 8,3 112 B14 200 1,6/0,6 3,9/1,8 100 B5 250
1500/750 1,0/0,25 2,4/1,0 90 B5 200 3,0/1,0 6,3/3,0 112 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B5 200
2,2/0,48 4,6/1,15 90 B5 200 630 750 0,55 1,8 90 B5 200
3,0/0,75 6,7/1,7 100 B14 200 1000 0,75 2,2 90 B5 200
4,1/1,0 8,8/2,1 112 B14 200 1,1 3,15 90 B5 200
1,5 3,9 100 B5 250
450 1500 1,1 2,8 90 B5 200 1500 1,5 3,5 90 B5 200
3000 3,0 6,7 100 B14 200 2,2 5,5 100 B5 250
4,0 8,3 112 B14 200 3,0 7,1 100 B5 250
5,5 11 112 B14 200 4,0 8,6 112 B5 250
7,5 14,6 112 B14 200 5,5 11,4 132 B5 250
1500/750 1,0/0,25 2,4/1,0 90 B5 200 1000/500 0,8/0,15 2,3/0,9 90 B5 200
1500/1000 1,1/0,37 2,8/1,35 90 B5 200 1,2/0,22 3,1/1,15 100 B5 250
3000/1500 3,0/0,75 6,7/1,7 100 B14 200 1500/750 2,5/0,6 5,6/2,2 100 B5 250
4,1/1,0 8,8/2,1 112 B14 200 3,8/1,0 8,1/3,4 112 B5 250
5,5/1,4 11,4/4,3 132 B5 250
500 1500 1,1 2,8 90 B5 200 1500/1000 2,2/0,75 5,3/2,3 100 B5 250
1,5 3,5 90 B5 200 3,0/1,0 6,3/3,0 112 B5 250
3000 4,0 8,3 112 B5 250 6,0 12,5/5,4 132 B5 250
5,5 11 132 B5 250
7,5 14,6 132 B5 250
11 20,5 132 B5 250
1000/500 0,48/0,08 1,6/0,58 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B5 200
1,4/0,35 3,3/1,35 90 B5 200
1500/1000 1,1/0,37 2,8/1,35 90 B5 200
1,6/0,6 3,9/1,8 100 B5 250
3000/1500 6,0/1,5 13,3/3,2 132 B5 250
7,8/2,0 16,2/4,1 132 B5 250

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 073
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

710 750 0,75 2,2 100 B5 250 800 1500/1000 6,0/2,0 12,5/5,4 132 B5 250
1,1 3,15 100 B5 250 8,5/3,0 17,9/7,6 160 B5 350
1000 1,1 3,15 90 B5 200 12/3,5 24/9,5 160 B5 350
1,5 3,9 100 B5 250 14/4,8 30/12 180 B5 350
2,2 5,4 112 B5 250 18/6,0 36/14 180 B5 350
3,0 7,4 132 B5 250
1500 3,0 7,1 100 B5 250 900 750 1,1 3,15 100 B5 250
4,0 8,6 112 B5 250 1,5 5,15 112 B5 250
5,5 11,4 132 B5 250 2,2 5,4 132 B5 250
7,5 15,4 132 B5 250 3,0 7,6 132 B5 250
11 22 160 B5 350 4,0 9,3 160 B5 350
1000/500 1,2/0,22 3,1/1,15 100 B5 250 1000 3,0 7,4 132 B5 250
1,85/0,33 4,6/1,6 112 B5 250 4,0 9,2 132 B5 250
3,3/0,75 9,3/3,6 132 B5 250 5,5 12,7 132 B5 250
1500/750 3,8/1,0 8,1/3,4 112 B5 250 7,5 15,7 160 B5 350
5,5/1,4 11,4/4,3 132 B5 250 11 22 160 B5 350
7,0/1,7 15,2/5,1 132 B5 250 1500 11 22 160 B5 350
11/3,0 24/9,5 160 B5 350 15 29,5 160 B5 350
1500/1000 4,5/1,5 9,5/3,8 132 B5 250 18,5 36 180 B5 350
6,0/2,0 12,5/5,4 132 B5 250 22 43 180 B5 350
8,5/3,0 17,9/7,6 160 B5 350 30 52 200 B5 350
12/3,5 24/9,5 160 B5 350 1000/500 3,3/0,75 9,3/3,6 132 B5 250
4,4/1,1 11/4,4 132 B5 250
800 750 1,1 3,15 100 B15 250 6,3/1,5 15,7/5,4 160 B5 350
1,5 5,15 112 B5 250 8,4/2,2 20,5/7,0 160 B5 350
2,2 5,4 132 B5 250 1500/750 11/3,0 24/9,5 160 B5 350
1000 2,2 5,4 112 B5 250 14/3,5 30,5/11,4 160 B5 350
3,0 7,4 132 B5 250 16/4 32,5/11,9 180 B5 350
4,0 9,2 132 B5 250 20/5,5 39/16,2 180 B5 350 BVAXN 12/56
5,5 12,7 132 B5 250 28/7,0 52/16,2 200 B5 350
1500 5,5 11,4 132 B5 250 1500/1000 12/3,5 24/9,5 160 B5 350
7,5 15,4 132 B5 250 14/4,8 30/12 180 B5 350
11 22 160 B5 350 18/6,0 36/14 180 B5 350
15 29,5 160 B5 350 20/7,0 41/16,2 200 B5 350
18,5 36 180 B5 350 25/9,0 47/18,5 200 B5 350
1000/500 2,6/0,5 7,1/2,8 132 B5 250 33/11 61/24 225 B5 350
3,3/0,75 9,3/3,6 132 B5 250
4,4/1,0 11/4,4 132 B5 250
1500/750 5,5/1,4 11,4/4,3 132 B5 250
7,0/1,7 15,2/5,1 132 B5 250
11/3,0 24/9,5 160 B5 350
14/3,5 30,5/11,4 160 B5 350
16/4,0 32,5/11,9 180 B5 350

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 074
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

1000 750 2,2 5,4 132 B5 250 1120 750 4,0 9,3 160 B5 350
3,0 7,6 132 B5 250 5,5 11,4 160 B5 350
4,0 9,3 160 B5 350 7,5 16,1 160 B5 350
5,5 11,4 160 B5 350 11 23,5 180 B5 350
7,5 16,1 160 B5 350 15 31 200 B5 400
1000 5,5 12,7 132 B5 250 1000 7,5 15,7 160 B5 350
7,5 15,7 160 B5 350 11 22 160 B5 350
11 22 160 B5 350 15 29,5 180 B5 350
15 29,5 180 B5 350 20 40 200 B5 400
1500 15 29,5 160 B5 350 22 43 200 B5 400
18,5 36 180 B5 350 30 57 225 B5 450
22 43 180 B5 350 1500 30 52 200 B5 400
30 52 200 B5 350 37 66 225 B5 450
37 66 225 B5 450 45 82 225 B5 450
45 82 225 B5 450 55 (L) 97 250 B5 550
1000/500 4,4/1,0 11/4,4 132 B5 250 75 (L) 132 280 B5 550
6,3/1,5 15,7/5,4 160 B5 350 90 (L) 157 280 B5 550
8,8/2,2 20,5/7,0 160 B5 350 1000/500 7,5/1,85 19/6,7 160 B5 350
12,5/3,0 32,5/11 180 B5 350 8,8/2,2 20,5/7,0 160 B5 350
15,5/3,3 34/11 200 B5 350 12,5/3,0 32,5/11 180 B5 350
1500/750 16/4,0 32,5/11,9 180 B5 350 15,5/3,3 34/11 200 B5 400
20/5,5 39/16,2 180 B5 350 18,5/4,4 40/13,3 200 B5 400
28/7,0 52/16,2 200 B5 350 22/5,5 44,5/16 225 B5 450
32/8,0 60/19 225 B5 450 27/6,6 52/20 225 B5 450
37/10 69/24,5 225 B5 450 1500/750 32/8,0 60/19 225 B5 450
1500/1000 18/6,0 36/14 180 B5 350 37/10 69/24,5 225 B5 450
20/7,0 41/16,2 200 B5 450 39/9,5 (L) 72/21 225 B5 450
25/9,0 47/18,5 200 B5 350 44/11 (L) 78/24 225 B5 450
33/11 61/24 225 B5 450 49/11 (L) 84/23 250 B5 550
68/17 (L) 125/43,5 280 B5 550
80/20 (L) 140/48 280 B5 550

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 075
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

1250 750 5,5 11,4 160 B5 350 1400 1000/500 27/6,6 52/20 225 B5 450
7,5 16,1 160 B5 350 30/7,0 58/19 250 B5 550
11 23,5 180 B5 350 40/8,0 (L) 74/24 280 B5 550
15 31 200 B5 400 48/9,5 (L) 88/28 280 B5 550
18,5 37 225 B5 450 60/12 (L) 106/22 315 B5 660
22 44,5 225 B5 450 70/14 (L) 125/33 315 B5 660
1000 15 29,5 180 B5 350 85/16 (L) 150/37 315 B5 660
20 40 200 B5 400 105/20 (L) 185/47 315 B5 660
22 43 200 B5 400
30 57 225 B5 450
37 67 225 B5 450
1500 45 82 225 B5 450
55 (L) 97 250 B5 550
75 (L) 132 280 B5 550
90 (L) 157 280 B5 550
110 (L) 200 315
132 (L) 240 315
160 (L) 285 315
1000/500 15,5/3,3 34/11 200 B5 400
18,5/4,4 40/13,3 200 B5 400
22/5,5 44,5/16 225 B5 450
27/6,6 52/20 225 B5 450
30/7 (L) 58/19 250 B5 550
1500/750 44/11 (L) 78/24 225 B5 450
49/11 (L) 84/23 250 B5 550
68/17 (L) 125/43,5 280 B5 550
80/20 (L) 140/48 280 B5 550

1400 750 11 23,5 180 B5 350 BVAXN 12/56


15 31 200 B5 400
18,5 37 225 B5 450
22 44,5 225 B5 450
30 (L) 60 250 B5 550
45 (L) 88 280 B5 550
1000 30 57 225 B5 450
37 74 225 B5 450
45 (L) 81 280 B5 550
55 (L) 99 280 B5 550
75 (L) 136 315 B5 660
90 (L) 160 315 B5 660

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 400°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 076
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

355 1500 1,1 2,85 90 B14 160 710 750 1,1 3,5 112 B5 250
3000 1,5 3,4 90 B14 160 1000 1,1 3,6 100 B5 250
1,5 4,2 112 B5 250
400 1500 1,1 2,85 90 B5 200 2,2 5,2 132 B5 250
3000 1,5 3,4 90 B5 200 3,0 7,5 132 B5 250
2,2 4,8 100 B14 200 1500 3,0 7,0 112 B5 250
3,0 6,2 112 B14 160 4,0 9,0 132 B5 250
3000/1500 3,0/0,8 7,0/2,0 112 B14 160 5,5 12 132 B5 250
7,5 14,5 160 B5 350
450 1500 1,1 2,85 90 B5 200 11 23 160 B5 350
3000 3,0 6,2 112 B14 200 1000/500 2,0/0,33 5,0/2,5 132 B5 250
3,2/0,7 7,0/4,0 132 B5 250
500 1500 1,5 4,0 100 B5 250 1500/750 3,7/0,9 9,2/3,8 132 B5 250
3000 4,0 8,5 132 B5 250 5,0/1,3 11,5/4,5 132 B5 250
5,5 11 132 B5 250 10/3,0 25/10,5 160 B5 350
1500/1000 4,2/1,25 10/3,2 132 B5 250
7,5  14,5 160 B14 250
7,5/2,2 17/6,0 160 B5 350
1500/750 2,5/0,55 6,5/2,5 112 B5 250
12/3,5 28/11 160 B5 350
1500/1000 2,4/0,75 6,8/2,8 112 B5 250
3000/1500 3,0/0,8 7,0/2,0 112 B5 250
6,0/1,6 13/3,5 132 B5 250 800 750 1,1 3,5 112 B5 250
1,5 4,2 132 B5 250
560 1500 1,5 4,0 100 B5 250 2,2 6,0 132 B5 250
2,2 6,0 100 B5 250 1000 2,2 5,2 132 B5 250
3,0 7,0 112 B5 250 3,0 7,5 132 B5 250
1500/750 2,5/0,55 6,5/2,5 112 B5 250 4,0 9,4 132 B5 250
3,7/0,9 9,2/3,8 132 B5 250 7,5 16,5 160 B5 350
1500/1000 3,0/0,9 7,0/2,5 132 B5 250 1500 5,5 12 132 B5 250
7,5 14,5 160 B5 350

630 750 0,55 2,0 100 B5 250 11 23 160 B5 350

1000 1,5 4,2 112 B5 250 15 31 160 B5 350

1500 2,2 6,0 100 B5 250 18,5 37 180 B5 350

3,0 7,0 112 B5 250 1000/500 2,0/0,33 5,0/2,5 132 B5 250

4,0 9,0 132 B5 250 3,2/0,7 7,0/4,0 132 B5 250

5,5 12 132 B5 250 6,2/1,3 15/4,2 160 B5 350

1000/500 2,0/0,33 5,0/2,5 132 B5 250 1500/750 5,0/1,3 11,5/4,5 132 B5 250

1500/750 2,5/0,55 6,5/2,5 112 B5 250 10/3,0 25/10,5 160 B5 350

3,7/0,9 9,2/3,8 132 B5 250 13/3,5 32/12,5 160 B5 350

5,0/1,3 11,5/4,5 132 B5 250 16/4 33/15 180 B5 350


1500/1000 7,5/2,2 17/6,0 160 B5 350
12/3,5 28/11 160 B5 350

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 400°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 077
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

900 750 1,1 3,5 112 B5 250 1000 1500/750 16/4,0 33/15 180 B5 350
1,5 4,2 132 B5 250 20/5,0 42/16 180 B5 350
2,2 6,0 132 B5 250 28/7,0 56/16,5 200 B5 350
4,0 10 160 B5 350 33/8,0 59/17,4 225 B5 450
1000 3,0 7,5 132 B5 250 39/9,5 76/25 225 B5 450
4,0 9,4 132 B5 250 1500/1000 16,5/5,5 32/11,8 180 B5 350
7,5 16,5 160 B5 350 31/10 60/21 225 B5 450
11 32,5 160 B5 350
1500 11 23 160 B5 350 1120 750 4,0 10 160 B5 350
15 31 160 B5 350 5,5 14,5 160 B5 350
18,5 37 180 B5 350 7,5 19 160 B5 350
22 43 180 B5 350 11 26 180 B5 350
30 57 200 B5 350 15 35 200 B5 400
1000/500 3,2/0,7 7,0/4,0 132 B5 250 1000 7,5 16,5 160 B5 350
6,2/1,3 15/4,2 160 B5 350 11 23,5 160 B5 350
8,4/1,8 18,5/5,1 160 B5 350 15 33 180 B5 350
1500/750 10/3,0 25/10,5 160 B5 350 22 48 200 B5 400
13/3,5 32/12,5 160 B5 350 1000/500 6,2/1,3 15/4,2 160 B5 350
16/4,0 33/15 180 B5 350 8,4/1,8 18,5/5,1 160 B5 350
20/5,0 42/16 180 B5 350 12,5/3,0 26/8,0 180 B5 350
28/7,0 56/16,5 200 B5 350 20/4,5 40/14 200 B5 400
1500/1000 12/3,5 28/11 160 B5 350 22/5,0 45/14,5 225 B5 450
16,5/5,5 32/11,8 180 B5 350 27/6,0 54/19 225 B5 450
31/10 60/21 225 B5 350
1250 750 5,5 14,5 160 B5 350
1000 750 2,2 6,0 132 B5 250 7,5 19 160 B5 350
4,0 10 160 B5 350 11 26 180 B5 350
5,5 14,5 160 B5 350 15 35 200 B5 400
7,5 19 160 B5 350 18,5 42 225 B5 450 BVAXN 12/56
1000 7,5 16,5 160 B5 350 1000 15 33 180 B5 350
11 23,5 160 B5 350 22 48 200 B5 400
15 33 180 B5 350 30 61 225 B5 450
1500 15 31 160 B5 350 1000/500 20/4,5 40/14 200 B5 400
18,5 37 180 B5 350 22/5,0 45/14,5 225 B5 450
22 43 180 B5 350 27/6,0 54/19 225 B5 450
30 57 200 B5 350
37 69 225 B5 450 1400 750 11 26 180 B5 350
45 86 225 B5 450 15 35 200 B5 400
1000/500 6,2/1,3 15/4,2 160 B5 350 18,5 42 225 B5 450
8,4/1,8 18,5/5,1 160 B5 350 22 47,5 225 B5 450
12,5/3,0 26/8,0 180 B5 350 1000 30 61 225 B5 450
20/4,5 40/14 200 B5 350 1000/500 27/6,6 54/19 225 B5 450

1600 750 22 47,50 225 B5 450

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 078
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

° = Volume flow [m3/h] or


V° ==Volume flow [m3/h]
Volumenstrom [mor3/h] bzw. [m3/s] Tip
[m/s] speed u2 = 26 m/s
Umfangsgeschwindigkeit u2 = 26 m/s Trägheitsmoment
Moment of inertia II==0.014 kg m22
0,014kg/m V = Volumenstrom [m3/h] [m/s]
bzw. [m3/s] Tip speed u2 = 52 m/s u = 52 m/s
Umfangsgeschwindigkeit 2 Moment of inertia II == 0,014
Trägheitsmoment 0.014 kg m22
kg/m
pd = Dyn.
dyn. Druck [Pa]
pressure bzw.
[Pa] 0.1 [kp/m32]] Temperature
or x 0,1 Temperatur t t==20° C
20 °C ␦ Schachtdurchmesser
Casing diameter d.i.L.d.i.L.
= 359= mm
359 mm pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]]
0,1 [kp/m Temperaturet =t =20°
Temperatur ␦ 20C°C Schachtdurchmesser
Casing diameter d.i.L.d.i.L.
= 359= mm
359 mm
c ==Flow
Srömungsgeschwindigkeit
velocity [m/s] [m/s] Dichte == 1.2
Density kg/m33
1,2 kg/m Austrittsquerschnitt
Outlet cross section A 0.10 m22
A22 = 0,10 cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density == 1,2
Dichte kg/m33
1.2 kg/m Austrittsquerschnitt
Outlet cross section AA22 == 0,10 m22
0.10 m

140
BVAXN 12/56/355/D – n = 1360 rpm 800
BVAXN 12/56/355/D – n = 2820 rpm
125 0,55 ␩ = 0,46 710 0,79 ␩ = 0,70
0,52 0,43 0,76 0,67
112 630

100 0,47 560 0,71


0,38 0,62

pd

pd
0,42 0,66
90 0,32 500 0,56

25° 25°

pd

pd
➞➞
➞➞

80 450

(Pa)
(Pa)

35° 35°
pressure increase 6⌬ptpt[Pa]

pressure increase 6⌬ptpt[Pa]


71 0,33 Schaufelwinkel
Blade pitch angel 400 0,57 Blade pitch angle
Schaufelwinkel
20° 20°
63 355
30° 30°
TotalTotaldruckerhöhung

TotalTotaldruckerhöhung
56 315
· 15° 0,23 · 15° 0,47
50 280
25° 25°

45 250
20° 0,37 20°
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15°
900

1 000

1 120

1 250

1 400

1 600

1 800

2 000

2 240

2 500

2 800

3 150

3 550

2 240

2 500

2 800

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
0,25

0,28

3,15 0,315

3,55 0,355

0,4

0,45

0,5

0,56

0,63

0,71

0,8

0,9

1,0

Pw = = [kW] Pw = = [kW]
0,63

0,71

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5
␩ [m3/s] ➞ ␩ [m3/s] ➞
2,5

2,8

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25
c [m/s] ➞ c [m/s] ➞
4,0

5,0

6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

25

31,5

40

50

63

80

100

125

160

200

250

315

400
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with duct 2.5 D
mit Rohrleitung 2,5 D pd [Pa] ➞
3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5
c [m/s] ➞ c [m/s] ➞
8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

125

50

63

80

100

125

160

200

250

315

400

500

630

800
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
87
Gesamt-Schalleistungspegel Lw [dB]

101

w [dB]
acoustic powerLlevel
acoustic power level

=
=

86 5° 100
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

5° 85
␩· 1000 · 3600

99
␩· 1000 · 3600

an der
an der

Gesamt-Schalleistungspegel
power input
power input

15° 84 15° 98
10° 10°
83 97
35°
Leistungsbedarf


Leistungsbedarf

82 0° 96
requirement

35°
requirement

30° 81 30° 95
Max. mögliche 25° Max. mögliche 25°
80 94
Motorbau- Motorbau-

Lw (dB)
Lw (dB)

Pw [kW]=
Pw [kW]=

20° 79 93
Welle:
Shaft

20°
Welle:
Shaft

größen: siehe größen: siehe

Total
Total

Maßblätter 78 Maßblätter 92
77 91

V° = =Volume flow [m3/h]


Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 28 m/s
Umfangsgeschwindigkeit u2 = 28 m/s Trägheitsmoment
Moment of inertia I I==0.024 kg m22
0,024kg/m V° = Volume flow [m3/h] or
= Volumenstrom [m3/h] [m/s]
bzw. [m3/s] Tip speed u2 = 59 m/s
Umfangsgeschwindigkeit u2 = 59 m/s Moment of inertia II== 0.024
Trägheitsmoment kg m22
0,024kg/m
3 Temperature
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t t==20°
20 C
␦°C Schachtdurchmesser
Casing diameter d.i.L. d.i.L.
= 401=mm401 mm pd == Dyn.
pd dyn. pressure
Druck [Pa] bzw.
[Pa] or xx 0.1 [kp/m32]]
0,1 [kp/m Temperaturet =
Temperatur t =20°
␦ 20 C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 401= mm
401 mm
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2 kg/m33
1,2 kg/m Austrittsquerschnitt 2 0,126 m22
Outlet cross section A = 0.126 cc ==Flow
Srömungsgeschwindigkeit
velocity [m/s] [m/s] Density == 1,2
Dichte kg/m33
1.2 kg/m Austrittsquerschnitt A22 = 0,126 m22
Outlet cross section A = 0.126

200
BVAXN 12/56/400/D – n = 1360 rpm 1000
BVAXN 12/56/400/D – n = 2895 rpm
0,83 ␩ = 0,74
180 0,66 ␩ = 0,57 900 0,75 0,71
0,63 0,54
160 800 0,70
0,66
pd

0,58
140 0,49 710 0,60
pd

0,50
0,53
0,43
125 630 25°
pd

25°
pd
➞➞

➞➞

112 560 35°


0,61 Schaufelwinkel
Blade pitch angle
(Pa)

(Pa)

35°
20°
0,44
[Pa]

[Pa]

Blade pitch angle


Schaufelwinkel
100 500
pressure increase6⌬ptpt

pressure increase6⌬ptpt

20°
30°
90 450
30°
TotalTotaldruckerhöhung

TotalTotaldruckerhöhung

80
15° 0,51
400
· 15° 0,34 · 25°
71 25° 355

63 315 0,41

0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20°


1 400

1 600

1 800

2 000

2 240

2 500

2 800

3 150

3 550

4 000

4 500

5 000

5 600

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
0,4

0,45

0,5

0,56

0,63

0,71

0,8

0,9

1,0

1,12

1,25

1,4

1,6

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

␩ [m3/s] ➞ ␩ [m3/s] ➞
3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

c [m/s] ➞ c [m/s] ➞
5,0

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

31,5

40

50

63

80

100

125

160

200

250

315

400

500

with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

c [m/s] ➞ c [m/s] ➞
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200

63

80

100

125

160

200

250

315

400

500

630

800

1 000

free outlet pd [Pa] ➞ pd [Pa] ➞


frei ausblasend freifree outlet
ausblasend
89
w [dB]

103
w [dB]
acoustic powerLlevel
=

acoustic power Llevel

5° 88 102
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

5° 15°
␩· 1000 · 3600

87 10° 101
␩· 1000 · 3600
an der

an der
Gesamt-Schalleistungspegel

Gesamt-Schalleistungspegel
power input

power input

10° 15° 86 0° 35° 100


85 99
30°
Leistungsbedarf


Leistungsbedarf

35° 84 25° 98
requirement

requirement

30° 83
Max. mögliche 25° 97
82 Max. mögliche 20°
Motorbau- 96
20° Motorbau-
Lw (dB)
Pw [kW]=

Lw (dB)

Pw [kW]=

81
Welle:
Shaft

95
Welle:
Shaft

größen: siehe größen: siehe


Total
Total

Maßblätter 80 94
Maßblätter
79 93

*Luftrichtung
* rounded toDstandard
(über Motor drückend) – Luftrichtung S (über Motor saugend) auf Anfrage · auf Normzahlen gerundete Werte
values Max. motor
For maximum mögliche Motorbaugrößen:
sizes siehe Maßblätter
please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 079
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V° = Volume flow [m3/h] or [m/s] Tip speed u = 33 m/s Moment of inertia II== 0.041 2 ° = Volume flow [m3/h] or [m/s] 2
= Volumenstrom [m3/h] bzw. [m3/s] 2
Umfangsgeschwindigkeit u2 = 33 m/s Trägheitsmoment 0,041kg/m
kg m2 V Tip speed u2 = 67 m/s
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 67 m/s Moment of inertia I I==0.041
Trägheitsmoment 0,041kg/m
kg m2
pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C
␦ Casing diameter d.i.L.d.i.L.
= 450= mm pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C Casing diameter d.i.L. d.i.L.
= 450=mm
pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] Temperatur t = 20° C 3 Schachtdurchmesser 450 mm pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] Temperatur t = 20° C3 ␦ Schachtdurchmesser 450 mm
c = Flow velocity [m/s] Density = 1.2 kg/m Outlet cross section A
A2 == 0,159 m22
0.159 m c = Flow velocity [m/s] Density = 1.2 kg/m 3 Outlet cross section A 2
c = Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m3 Austrittsquerschnitt 2 c = Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m Austrittsquerschnitt A2 == 0.159
0,159 m
m2 2

280
BVAXN 12/56/450/D – n = 1400 rpm BVAXN 12/56/450/D – n = 2860 rpm
1400
0,75 ␩ = 0,66
250 0,72 1250
0,63
0,85 ␩ = 0,76
224 1120 0,82 0,73
0,67
0,58

pd
200 0,62 1000
0,52 0,77
0,68

pd
180 900 0,72
25° 0,62

pd
160
(Pa)➞➞

800 25°

(Pa)➞➞
35°

pd
0,53 Blade pitch angle
Schaufelwinkel
pressure increase 6⌬ptpt[Pa]

pt[Pa]
140 20° 710 35°
Blade pitch angle
0,63 Schaufelwinkel

pressure increase 6⌬ pt
30° 20°
125 630
TotalTotaldruckerhöhung

TotalTotaldruckerhöhung
30°
112 15° 0,43 560
· ·
100
25° 15° 0,53
500
25°
90 0,33 450
0° 0° 5° 5° 10° 10° 15° 20° 0,43 20°
0° 0° 5° 5° 10° 10° 15°
2 240

2 500

2 800

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

Leistungsbedarf

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000
Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW]
0,63

0,71

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

Pw = = [kW]

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0
␩ [m3/s] ➞ [m3/s] ➞

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5
c [m/s] ➞ c [m/s] ➞
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160

40

50

63

80

100

125

160

200

250

315

400

500

630
with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞ with duct 2.52,5
DD pd [Pa] ➞
mit Rohrleitung
5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45
c [m/s] ➞ c [m/s] ➞
20

25

31,5

40

50

63

80

100

125

160

200

250

315

80

100

125

160

200

250

315

400

500

630

800

1 000

1 250
pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree outlet
ausblasend
92
Gesamt-Schalleistungspegel Lw [dB]
acoustic power level

108

Gesamt-Schalleistungspegel Lw [dB]
=

Total acoustic power level


=

5° 91 107
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]


␩· 1000 · 3600

15° 90
␩· 1000 · 3600

10°
an der

106
an der


power input

power input

89 105
0° 35° 88 15° 104
10°
Leistungsbedarf

30°
Leistungsbedarf

87
requirement

25° 103
requirement

35°
86 0° 102
Max. mögliche 20° Max. mögliche 30°
85 25° 101
Motorbau-
Lw (dB)

Motorbau-
Pw [kW]=

Lw (dB)
Pw [kW]=

84
Welle:
Shaft

Welle:
Shaft

größen: siehe größen: siehe 100


Total

Maßblätter 83 20° 99
82 Maßblätter
98

° = Volume flow [m3/h] or [m/s]


V Tip speed u = 38 m/s Moment of inertia I = 0.073 kg/m22
V° = =Volume flow [m3/h]
Volumenstrom [mor3/h] bzw. [m3/s] Tip
[m/s] speed u2 = 24 m/s
Umfangsgeschwindigkeit u2 = 24 m/s Moment of inertia I I==0.073
Trägheitsmoment 0,073kg/m
kg m2
2 2
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 38 m/s Trägheitsmoment I = 0,073 kg m
pd = Dyn. pressure [Pa] or x 0.1 [kp/m3] Temperature t = 20 °C Casing diameter d.i.L. = 504 mm
[kp/m32]] Temperature pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m2] Temperatur t = 20° C3 Schachtdurchmesser d.i.L. = 504 mm
pd =
pd = Dyn. pressure
dyn. Druck [Pa]
[Pa] or x
bzw. 0.1 [kp/m
x 0,1 Temperatur tt==20°
20 °C
C ␦ Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 504= mm
504 mm ␦
c = Flow velocity [m/s] Density = 1.2 kg/m 3 Outlet cross section A 2
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2 kg/m33
1,2 kg/m Outlet cross section A = 0.2
Austrittsquerschnitt A 2 = 0,2 m m 2
2 c = Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m Austrittsquerschnitt A2 == 0.2
0,2 m
m2 2
2

BVAXN 12/56/500/D – n = 910 rpm 400


BVAXN 12/56/500/D – n = 1400 rpm
140
0,69 ␩ = 0,60 355
125 ␩ = 0,71
0,80
0,66 0,57
315 0,77 0,68
112
0,61
0,52 280
pd

100 0,72
0,56 0,63
pd

0,46
0,67
90 250 0,57
25°
pd

80 224 25°
(Pa)➞➞

pd
(Pa)➞➞

35°
BVAXN 12/56
0,47 Schaufelwinkel
Blade pitch angle 35°
pt[Pa]
pressure increase 6⌬ptpt[Pa]

71 200
20° 0,58 Blade pitch angle
Schaufelwinkel
⌬ pt

20°
pressure increase 6

63 30° 180
Total Totaldruckerhöhung
TotalTotaldruckerhöhung

30°
56 160
15° 0,37 ·
· 15° 0,48
50 25° 140
25°
45 125
20°
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 0,38
3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

Leistungsbedarf
2 000

2 240

2 500

2 800

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW]
0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

Pw = = [kW]
0,56

0,63

0,71

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

[m3/s] ➞ ␩ [m3/s] ➞

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18
2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

c [m/s] ➞ c [m/s] ➞
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200
5,0

6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

80

with duct 2.52,5


DD pd [Pa] ➞ mitwith duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞
mit Rohrleitung
6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

c [m/s] ➞ c [m/s] ➞
25

31,5

40

50

63

80

100

125

160

200

250

315

400
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160

pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
97
w [dB]

87
w [dB]

acoustic powerLlevel


=
acoustic power Llevel
=

86 96

V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

95
␩· 1000 · 3600

85
an der
␩· 1000 · 3600

Gesamt-Schalleistungspegel
an der

Gesamt-Schalleistungspegel

power input

10° 15° 94
power input

84
83 10° 15° 93
Leistungsbedarf

0° 35°
Leistungsbedarf

82 92
requirement

30°
requirement

25° 0° 35° 91
81 Max. mögliche 30°
Max. mögliche 25° 90
20° 80 Motorbau-
Motorbau-
Lw (dB)
Pw [kW]=
Lw (dB)

89
Welle:
Shaft
Pw [kW]=

79
Welle:
Shaft

größen: siehe größen: siehe 20°


Total
Total

78 Maßblätter 88
Maßblätter 87
77
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 080
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

° = Volume flow [m3/h] or


V° = =Volume flow [m3/h]
Volumenstrom [mor3/h] bzw. [m3/s] Tip
[m/s] speed u2 = 76 m/s
Umfangsgeschwindigkeit u2 = 76 m/s Moment of inertia I I==0.073
Trägheitsmoment kg m22
0,073kg/m V = Volumenstrom [m3/h] bzw. [m3/s] Tip
[m/s] speed u2 = 27 m/s
Umfangsgeschwindigkeit u2 = 27 m/s Trägheitsmoment
Moment of inertia I I==0.12 kg m22
0,12kg/m
pd = Dyn. pressure
dyn. Druck [Pa]
[Pa] or x 0,1
bzw. [kp/m32]] Temperature
0.1 [kp/m Temperatur tt == 20°
20 °C
C ␦ Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 504= mm
504 mm pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]] Temperature
0,1 [kp/m Temperatur tt ==20°
20 °C
C ␦ Schachtdurchmesser
Casing diameter d.i.L. d.i.L.
= 565=mm
565 mm
c ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte ==1.2 kg/m33
1,2kg/m Outlet
Austrittsquerschnitt 0.2 m22
cross section A 2 = 0,2
2 c ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte ==1.2 kg/m33
1,2kg/m Austrittsquerschnitt
Outlet 0,25 m22
cross section A22 = 0.25

1800
BVAXN 12/56/500/D – n = 2880 rpm 200
BVAXN 12/56/560/D – n = 920 rpm
1600 0,87 ␩ = 0,78 180 0,76 ␩ = 0,67
0,84 0,75 0,73 0,64
1400 160

1250 0,79 140 0,68


0,70 0,59

pd

pd
0,74 0,63
1120 0,64 125 0,53

25° 25°

pd

pd
1000 112

(Pa)➞➞

(Pa) ➞

35° 35°
pt [Pa]

pressure increase 6⌬ptpt[Pa]


900 0,65 Blade pitch angle
Schaufelwinkel 100 0,54 Schaufelwinkel
Blade pitch angle
20° 20°
increase ⌬6 pt

800 90
30° 30°
Totaldruckerhöhung

TotalTotaldruckerhöhung
710 80
· 15° 0,55 · 15° 0,44
Total pressure

630 71
25° 25°

560 20° 63
20°
0,45 0,34
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15°
6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

2 800

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15
␩ [m3/s] ➞ ␩ [m3/s] ➞
9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5
c [m/s] ➞ c [m/s] ➞
50

63

80

100

125

160

200

250

315

400

500

630

800

6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100
with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45

50

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18
c [m/s] ➞ c [m/s] ➞
100

125

160

200

250

315

400

500

630

800

1000

1250

1600

12,5

16

20

25

31,5

40

50

63

80

100

125

160

200
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
110
Gesamt-Schalleistungspegel Lw [dB]

92

Gesamt-Schalleistungspegel Lw [dB]
Total acoustic power level
acoustic power level

=
=

109 5° 91
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]


␩· 1000 · 3600

108 90
␩· 1000 · 3600

an der
an der

power input
power input

15° 107 15° 89


10° 10°
106 88
35°
Leistungsbedarf
Leistungsbedarf

0° 105 0° 87
requirement

35°
requirement

30° 104 30° 86


Max. mögliche 25° Max. mögliche 25°
103 85
Motorbau- Motorbau-

Lw (dB)
Lw (dB)

Pw [kW]=
Pw [kW]=

Welle:
Shaft

102 84
Welle:

20°
Shaft

größen: siehe 20° größen: siehe


Total

Maßblätter 101 Maßblätter 83


100 82

Tip speed u2 = 41 m/s 2 ° = Volume flow [m3/h] or [m/s] Tip speed u2 = 23 m/s 2
V° = =Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 41 m/s Moment of inertia I I==0.12
Trägheitsmoment 0,12kg/m
kg m2 V
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 23 m/s Moment of inertia I I==0.223
Trägheitsmoment 0,223kg/m
kg m2
3 Temperature t = 20 °C pd 3 Temperature t = 20 °C
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C
␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 565=mm565 mm pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C3
␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 634=mm634 mm
Density = 1.2 kg/m33 2 Density 22
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m Outlet cross section A = 0.25
Austrittsquerschnitt A2 = 0,25 m2 m
2
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Dichte == 1.2
1,2 kg/m
kg/m3 Outlet cross section A = 0.31
Austrittsquerschnitt A = 0,31 m
2 m
2

500
BVAXN 12/56/560/D – n = 1400 rpm 140
BVAXN 12/56/630/D – n = 690 rpm
450 0,84 ␩ = 0,75 125 0,74 ␩ = 0,65
0,81 0,72 0,71 0,62
400 112

0,76 0,66
355 0,67 100 0,57
pd

pd

0,71 0,61
0,61 0,51
315 90
25° 25°
pd

pd

280 80
(Pa)➞➞

(Pa)➞➞

35° 35°
pressure increase 6⌬ptpt[Pa]

pt[Pa]

0,62
Blade pitch angle
250 Schaufelwinkel 71 0,52 Schaufelwinkel
Blade pitch angle
20° 20°
pressure increase 6⌬pt

224 63
30° 30°
TotalTotaldruckerhöhung

TotalTotaldruckerhöhung

200 56
· 15° 0,52 · 15° 0,42
180 50
25° 25°

160 20° 45
0,32
0,42
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15° 20°
4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

2 800

3 150

3 550

4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

0,8

0,9

1,0

1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

␩ [m3/s] ➞ ␩ [m3/s] ➞
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

c [m/s] ➞ c [m/s] ➞
16

20

25

31,5

40

50

63

80

100

125

160

200

250

4,0

5,0

6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

c [m/s] ➞ c [m/s] ➞
31,5

40

50

63

80

100

125

160

200

250

315

400

500

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

125

pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree
ausblasend
outlet
99
w [dB]

88
w [dB]
Total acoustic powerLlevel
=

acoustic power Llevel


==

5° 98 87
V̇[m3/h] · ⌬pt [Pa]

[Pa]
⌬pt [Pa]


␩· 1000 · 3600

97 86
an der

3600
1000 ·· 3600
der
Gesamt-Schalleistungspegel

Gesamt-Schalleistungspegel
an der
power input

power input

96 85
/h] ·· ⌬pt

10° 15° 10° 15°


an

95 84
␩· 1000

35°
Leistungsbedarf

Leistungsbedarf

V̇[m33/h]
Leistungsbedarf

0° 94 0° 83
requirement

requirement

35°
30° 30°
V̇[m
␩·

93 82
Max. mögliche 25° Max. mögliche 25°
92 81
Motorbau- Motorbau-
Lw (dB)
Pw [kW]=

Lw (dB)
[kW]=
Welle:
Shaft

91
PPww [kW]=

20° 20° 80
Welle:
Shaft
Welle:

größen: siehe größen: siehe


Total

Maßblätter 90 Maßblätter 79
89 78

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 081
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

flow [m3/h] Tip speed u2 = 30 m/s Moment of inertia II==0.223 2 ° = Volume flow [m3/h] or [m/s] 2
V = =Volume
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 30 m/s Trägheitsmoment 0,223kg/m
kg m2 V = Volumenstrom [m3/h] bzw. [m3/s] Tip speed u2 = 46 m/s
Umfangsgeschwindigkeit u2 = 46 m/s Moment of inertia I I==0.223
Trägheitsmoment 0,223kg/m
kg m2
3 Temperature t = 20 °C Casing diameter d.i.L.d.i.L.
= 634= mm 3 Temperature
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C3
␦ Schachtdurchmesser 634 mm pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t t==20°
20 C
°C
␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 634=mm634 mm
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1,2
1.2 kg/m
kg/m3 Outlet cross section A
Austrittsquerschnitt A2 == 0,31 m22
0.31 m cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3
3 Outlet cross section A
Austrittsquerschnitt A2 == 0.31 m22
0,31 m
2 2

BVAXN 12/56/630/D – n = 920 rpm 630


BVAXN 12/56/630/D – n = 1400 rpm
250
0,80 ␩ = 0,71 0,85 ␩ = 0,76
224 0,77
560
0,68 0,82 0,73

200 500
0,72 0,77
0,63

pd
0,68

pd
180 0,67 450
0,57 0,72
0,62
160 400
25° 25°

pd

pd
140 355

(Pa)➞➞
(Pa)➞➞

35° 35°
0,58 Blade pitch angle
Schaufelwinkel
0,63 Schaufelwinkel
Blade pitch angle

pt[Pa]
pt[Pa]

125 20° 315 20°

⌬ pt
6 pt

30°
pressure increase ⌬

pressure increase 6
112 280 30°

Total Totaldruckerhöhung
Total Totaldruckerhöhung

100 15° 0,48 250 15° 0,53


· ·
25° 25°
90 224

80 0,38 200
0,43
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20°

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000
4 000

4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1
1,12

1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

␩ [m3/s] ➞ ␩ [m3/s] ➞

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4
3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

c [m/s] ➞ c [m/s] ➞
20

25

31,5

40

50

63

80

100

125

160

200

250

315
8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

125

mit Rohrleitung
with duct 2.52,5DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

c [m/s] ➞ c [m/s] ➞
40

50

63

80

100

125

160

200

250

315

400

500

630
16

20

25

31,5

40

50

63

80

100

125

160

200

250

pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree outlet
ausblasend
101

w [dB]
92
w [dB]

acoustic powerLlevel

=
acoustic power Llevel
=

91 5° 100
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

90 99
␩· 1000 · 3600

15°
␩· 1000 · 3600

an der

10°
an der

Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel

power input
power input

89 10° 15° 98
0° 35° 88 35° 97
30° 0°
Leistungsbedarf
Leistungsbedarf

25° 87 96
requirement

30°
requirement

86 25° 95
Max. mögliche 20° Max. mögliche
85 94
Motorbau- Motorbau- 20°

Lw (dB)
Pw [kW]=
Lw (dB)
Pw [kW]=

84 93
Welle:
Shaft
Welle:
Shaft

größen: siehe größen: siehe

Total
Total

Maßblätter 83 Maßblätter 92
82 91

°
V° = =Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 26 m/s u = 26 m/s
Umfangsgeschwindigkeit Moment of inertia II == 0.40
Trägheitsmoment 0,40 kg/m
kg m2
2 V ==Volume flow [m /h]
Volumenstrom [m3or/h][m/s]
bzw. [m3/s]
3 Tip speed u2 = 35 m/s
Umfangsgeschwindigkeit u2 = 35 m/s Moment of inertia II== 0.40
Trägheitsmoment kg m22
0,40kg/m
3 2 pd == Dyn. pressure [kp/m32]] Temperaturet =
t =20°
20 C°C
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperaturet =t =20°
Temperatur ␦ 20C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 711= mm
711 mm pd dyn. Druck [Pa][Pa] or xx 0,1
bzw. 0.1 [kp/m Temperatur ␦ Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 711= mm
711 mm
cc ==Flow velocity [m/s] Density == 1,2
Dichte kg/m33
1.2 kg/m Outlet cross section AA2 == 0,39
Austrittsquerschnitt m22
0.39 m c = Flow velocity [m/s] Dichte == 1,2
Density kg/m33
1.2 kg/m Outlet cross section A = 0.4
Austrittsquerschnitt A22 = 0,4 mm22
Srömungsgeschwindigkeit [m/s] 2 c = Srömungsgeschwindigkeit [m/s]

BVAXN 12/56/710/D – n = 700 rpm BVAXN 12/56/710/D – n = 950 rpm


200 400

180 0,80 ␩ = 0,71 355


0,84 ␩ = 0,75
0,77 0,68
160 315 0,81 0,72

0,72
140 0,63 280 0,76
pd

0,67
pd

0,67
0,57 0,71
125 250 0,61
25°
pd

112 224
(Pa)➞➞

(Pa)➞➞

25°
pd

BVAXN 12/56
35°
pt[Pa]
pressure increase 6⌬ptpt[Pa]

100 0,58 Blade pitch angle


Schaufelwinkel 200 35°
20° 0,62 Schaufelwinkel
Blade pitch angle
pressure increase 6⌬pt

20°
90 180
30°
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung

30°
80 160
· 15° 0,48 ·
15° 0,52
71 140
25°
25°
63 0,38 125
20° 0,42
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15°
5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400
4 500

5 000

5 600

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3
1,25

1,4

1,6

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

␩ [m3/s] ➞ ␩ [m3/s] ➞
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16
3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

c [m/s] ➞ c [m/s] ➞
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160
6,3

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞
5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

c [m/s] ➞ c [m/s] ➞
20

25

31,5

40

50

63

80

100

125

160

200

250

315
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200

pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
99
w [dB]

92
w [dB]

acoustic powerLlevel
acoustic power Llevel

=
=

5° 91 98
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

90 97
␩· 1000 · 3600
␩· 1000 · 3600

an der
an der

Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel

power input
power input

89 96
10° 15°
88 5° 95
10° 15°
Leistungsbedarf
Leistungsbedarf

87 94
requirement


requirement

35° 0° 35°
30° 86 93
Max. mögliche 25° Max. mögliche
85 30° 92
Motorbau- Motorbau- 25°
Lw (dB)
Lw (dB)

Pw [kW]=
Pw [kW]=

84 91
Welle:
Shaft
Welle:
Shaft

größen: siehe 20° größen: siehe


Total
Total

Maßblätter 83 Maßblätter 20° 90


82 89

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 082
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V° = =Volume flow [m3/h]


Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 53 m/s
Umfangsgeschwindigkeit u2 = 53 m/s Moment of inertia II == 0.40
Trägheitsmoment kg m22
0,40 kg/m V° ==Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 30 m/s
Umfangsgeschwindigkeit u2 = 30 m/s Moment of inertia II == 0.69
Trägheitsmoment kg m22
0,69 kg/m
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]]
0,1 [kp/m Temperaturet =
Temperatur t =20°
20 C°C
␦ Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 711= mm
711 mm pd =
pd = Dyn. pressure
dyn. Druck [Pa]
[Pa] or x
bzw. [kp/m32]]
0.1 [kp/m
x 0,1 Temperature
Temperatur t t==20°
␦ 20 C°C Schachtdurchmesser
Casing diameter d.i.L.d.i.L.
= 797= 797
mm mm
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density == 1,2
Dichte kg/m33
1.2 kg/m Outlet cross section AA2 == 0,4
Austrittsquerschnitt m22
0.4 m cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1,2 kg/m33
1.2 kg/m Austrittsquerschnitt
Outlet cross sectionAA22==0,50.5mm22
2

900
BVAXN 12/56/710/D – n = 1430 rpm BVAXN 12/56/800/D – n = 720 rpm
280

800 0,87 ␩ = 0,78 250


0,83 ␩ = 0,74
0,84 0,75
710 224 0,78 0,71

630 0,79 200


0,70 0,73

pd
0,66

pd
0,74
560 0,64 180 0,68
0,58
25°

pd

➞➞
➞➞

500 160 25°

pd
(Pa)
(Pa)

35°
pressure increase 6⌬ptpt[Pa]

pressure increase 6⌬ptpt[Pa]


450 140 35°
0,65 Blade pitch angle
Schaufelwinkel
0,61
Blade pitch angle
Schaufelwinkel
20°
20°
400 125
30°
TotalTotaldruckerhöhung

TotalTotaldruckerhöhung
30°
355 112
· 15° 0,55 ·
15° 0,51
315 100
25°
25°
280 90
0,45 20° 0,41 20°
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15°
9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

6 300

7 100

8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

1,8

2,0

2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1
␩ [m3/s] ➞ ␩ [m3/s] ➞
6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14
c [m/s] ➞ c [m/s] ➞
25

31,5

40

50

63

80

100

125

160

200

250

315

400

8,0

10

12,5

16

20

25

31,5

40

50

63

80

100

125
with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞ with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞
9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35.5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20
c [m/s] ➞ c [m/s] ➞
50

63

80

100

125

160

200

250

315

400

500

630

800

16

20

25

31,5

40

50

63

80

100

125

160

200

250
pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree
ausblasend
outlet
106
w [dB]

96

w [dB]
acoustic powerLlevel
=

acoustic power Llevel


=

105 95
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]


␩· 1000 · 3600

104 94
an der

␩· 1000 · 3600


an der
Gesamt-Schalleistungspegel

Gesamt-Schalleistungspegel
power input

power input

103 93
10° 15° 102 92
10° 15°
Leistungsbedarf

35°
Leistungsbedarf

0° 101 91
requirement

35°
requirement


30° 100 90
Max. mögliche 25° Max. mögliche 30°
99 25° 89
Motorbau- Motorbau-
Lw (dB)
Pw [kW]=

Lw (dB)
Pw [kW]=

98 88
Welle:
Shaft

Welle:
Shaft

größen: siehe 20° größen: siehe


Total

20°

Total
Maßblätter 97 Maßblätter 87
96 86

° = Volume flow [m3/h] or [m/s]


V° = =Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 39 m/s u = 39 m/s
Umfangsgeschwindigkeit Moment of inertia II == 0.69
Trägheitsmoment 0,69 kg/m
kg m2
2 V = Volumenstrom [m3/h] bzw. [m3/s] Tip speed u2 = 60 m/s
Umfangsgeschwindigkeit u2 = 60 m/s Trägheitsmoment
Moment I =0.69
of inertia I = kg m22
0,69kg/m
2
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]]
0,1 [kp/m Temperaturet =t =
Temperatur 20C°C
20°
␦ Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 797= mm
797 mm pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]] Temperature
0,1 [kp/m Temperatur tt==20°
20 °C
C ␦ Schachtdurchmesser
Casing diameter d.i.L. d.i.L.
= 797=mm797 mm
3
c = Flow velocity [m/s]
c = Srömungsgeschwindigkeit [m/s] Density ==1,2
Dichte kg/m33
1.2kg/m Outlet cross sectionAA2 ==0,5
Austrittsquerschnitt 0.5mm22 cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Austrittsquerschnitt
Outlet cross section AA22 == 0.5 m22
0,5 m
2

BVAXN 12/56/800/D – n = 950 rpm 1120


BVAXN 12/56/800/D – n = 1450 rpm
500

450 1000 0,88 ␩ = 0,79


0,86 ␩ = 0,77
0,85 0,76
400 0,83 0,74 900
0,80
355 800 0,71
pd

0,78
0,69 0,75
pd

0,65
0,73
315 0,63 710
25°
pd

280 25° 630


(Pa)➞➞

(Pa)➞➞
pd

35°
0,66 Blade pitch
Schaufelwinkel
pt[Pa]

35°
pressure increase 6⌬ptpt[Pa]

250 560 angle


0,64 Schaufelwinkel
Blade pitch 20°
⌬ pt

20° angle
pressure increase 6

224 500 30°


TotalTotaldruckerhöhung
TotalTotaldruckerhöhung

30°
200 450
15° 0,56
15° 0,54
180 400 25°
25°
160 355
20°
0,46
° 0° 0° 5° 5° 10° 10° 15°
0° 0° 5° 5° 10° 10° 15° 0,44
12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000
8 000

9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW]
3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

Pw = = [kW]
2,24

2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

␩ · 1000 [m3/s] ➞ ␩ · 1000 [m3/s] ➞


7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

c [m/s] ➞ c [m/s] ➞
31,5

40

50

63

80

100

125

160

200

250

315

400

500
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200

with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40
6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

c [m/s] ➞ c [m/s] ➞
63

80

100

125

160

200

250

315

400

500

630

800

1000
25

31,5

40

50

63

80

100

125

160

200

250

315

400

pd [Pa] ➞ pd [Pa] ➞
frei ausblasend
free outlet freifree
ausblasend
outlet
110
Gesamt-Schalleistungspegel Lw [dB]

101
w [dB]
acoustic powerLlevel

acoustic power level


=

100 109
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

99 108
␩· 1000 · 3600

␩· 1000 · 3600


an der

an der
Gesamt-Schalleistungspegel
power input

power input

98 107
5° 15° 97 10° 15° 106
10°
Leistungsbedarf

Leistungsbedarf

0° 96 0° 35° 105
35°
requirement

requirement

95 30° 104
Max. mögliche 30° Max. mögliche
25° 94 25° 103
Motorbau- Motorbau-
Lw (dB)

Lw (dB)
Pw [kW]=

Pw [kW]=

93 102
Welle:

Welle:
Shaft

Shaft

größen: siehe größen: siehe 20°


Total

Total

20° 92 101
Maßblätter Maßblätter
91 100

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 083
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

flow [m3/h] Tip speed u2 = 33 m/s °V = Volume flow [m3/h] or [m/s]


V° = =Volume
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 33 m/s Moment of inertia II == 1.20
Trägheitsmoment kg m22
1,20 kg/m 3 = Volumenstrom [m /h] bzw. [m3/s] Tip speed u2 = 44 m/s
Umfangsgeschwindigkeit u2 = 44 m/s Moment of inertia II==1.20
Trägheitsmoment 1,20kg/m
kg m2
2
Temperature 3
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
3
[kp/m2]] Temperatur t t==20°
␦20 C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 894= mm
894 mm pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperaturet =
Temperatur ␦ t =20°
20 C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 894= mm
894 mm
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1,2 kg/m33
1.2 kg/m Outlet cross section AA2 == 0,63
Austrittsquerschnitt m22
0.63 m cc ==Flow velocity [m/s] Density == 1,2 kg/m33
1.2 kg/m Outlet cross section A
A2 == 0,63 m22
0.63 m
2 Srömungsgeschwindigkeit [m/s] Dichte Austrittsquerschnitt 2

355
BVAXN 12/56/900/D – n = 720 rpm BVAXN 12/56/900/D – n = 950 rpm
630

315 0,86 ␩ = 0,77 560 ␩ = 0,78


0,87
0,83 0,74 0,84 0,73
280 500

250 0,78 450 0,79


0,69 0,68

pd

pd
0,73 0,74
224 0,63 400 0,64

25° 25°

➞➞
pd
200

pd
355
(Pa)➞➞

(Pa)
35° 35°
pt[Pa]

[Pa]
180 0,64 Schaufelwinkel
Blade pitch angle 315 0,63 Schaufelwinkel
Blade pitch angle

pressure increase 6⌬ptpt


⌬ pt

20° 20°
pressure increase 6

160 280
Total Totaldruckerhöhung

30°

TotalTotaldruckerhöhung
30°
140 250
· 0,54 ·
15° 15° 0,53
125 224
25° 25°
112 200
0° 0° 5° 5° 10° 10° 15° 0,44 20° 0,43 20°
0° 0° 5° 5° 10° 10° 15°
9 000

10 000

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

11 200

12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW]
2,5

2,8

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

Pw = = [kW]

3,15

3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5
␩ [m3/s] ➞ ␩ [m3/s] ➞
4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20
c [m/s] ➞ c [m/s] ➞
10

12,5

16

20

25

31,5

40

50

63

80

100

125

160

16

20

25

31,5

40

50

63

80

100

125

160

200

250
mit Rohrleitung
with duct 2.52,5DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28
c [m/s] ➞ c [m/s] ➞
20

25

31,5

40

50

63

80

100

125

160

200

250

315

31,5

40

50

63

80

100

125

160

200

250

315

400

500
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
99
Gesamt-Schalleistungspegel Lw [dB]

105

Gesamt-Schalleistungspegel Lw [dB]
acoustic power level

Total acoustic power level


=

98 104
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

5° 97
␩· 1000 · 3600

␩· 1000 · 3600

103
an der

an der
power input

power input

96 5° 102
10° 15° 95 10° 15° 101
Leistungsbedarf

Leistungsbedarf

0° 35° 94 0° 100
35°
requirement

requirement

30° 93 99
Max. mögliche 25° Max. mögliche 30°
92 25° 98
Motorbau- Motorbau-
Lw (dB)

Lw (dB)
Pw [kW]=

Pw [kW]=

91 97
Welle:

Welle:
Shaft

Shaft

größen: siehe 20° größen: siehe


Total

90 20° 96
Maßblätter Maßblätter
89 95

° = Volume flow [m3/h] or [m/s]


V° = =
Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 67 m/s
Umfangsgeschwindigkeit u2 = 67 m/s Moment of inertia II==1.20
Trägheitsmoment kg m22
1,20kg/m V = Volumenstrom [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s
Umfangsgeschwindigkeit u2 = 38 m/s Trägheitsmoment
Moment of inertia II == 2.05 kg m22
2,05 kg/m
3
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]]
0,1 [kp/m Temperature
Temperatur t t==20°
␦20 C
°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 894= mm
894 mm pd
pd == Dyn.
dyn. pressure [Pa]
Druck [Pa] or xx 0.1
bzw. [kp/m2]] Temperature
0,1 [kp/m Temperatur tt==20°
20 °C
C ␦ Schachtdurchmesser
Casing diameter d.i.L.d.i.L. = 1003
= 1003 mm mm
3
cc = =Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2 kg/m33
1,2 kg/m Outlet cross section A = 0.63
Austrittsquerschnitt A22 = 0,63 mm22 cc = =Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Austrittsquerschnitt A22 = 0,79 m
Outlet cross section A = 0.79 m22

BVAXN 12/56/900/D – n = 1450 rpm BVAXN 12/56/1000/D – n = 720 rpm


1400 450
0,89 ␩ = 0,80
1250
0,86
400 0,87 ␩ = 0,78
0,77
0,84 0,75
1120 355
0,81
0,72
pd

1000 315 0,79


0,76 0,70
pd

0,66
0,74
900 280 0,64
25°
pd

25°
pd
➞➞

250
➞➞

800
35°
BVAXN 12/56
0,67
(Pa)
(Pa)

Blade pitch angle


Schaufelwinkel 35°
pressure increase 6⌬ptpt[Pa]
pressure increase 6⌬ptpt[Pa]

710 20° 224 0,65 Schaufelwinkel


Blade pitch angle
20°
630 30° 200
30°
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung

560 15° 0,57 180


· · 15° 0,55
500 25° 160
25°

450 140
0,47
0° 0° 5° 5° 10° 10° 15° 20° 0,45 20°
0° 0° 5° 5° 10° 10° 15°
12 500

14 000

16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000
18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

71 000

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
3,55

4,0

4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

␩ [m3/s] ➞ ␩ [m3/s] ➞
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18
8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

c [m/s] ➞ c [m/s] ➞
12,5

16

20

25

31,5

40

50

63

80

100

125

160

200
40

50

63

80

100

125

160

200

250

315

400

500

630

with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25
11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45

c [m/s] ➞ c [m/s] ➞
25

31,5

40

50

63

80

100

125

160

200

250

315

400
80

100

125

160

200

250

315

400

500

630

800

1 000

1 250

pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet frei ausblasend
free outlet
102
w [dB]

111
w [dB]
acoustic powerLlevel

acoustic power Llevel


=

5° 110 101
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

109 5° 100
␩· 1000 · 3600

␩· 1000 · 3600
an der

an der

Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel

10° 15°
power input

power input

108 99
0° 35° 107 10° 15° 98
Leistungsbedarf

Leistungsbedarf

30° 106 0° 35° 97


requirement

requirement

25° 96
105 30°
Max. mögliche Max. mögliche 25°
20° 104 95
Motorbau- Motorbau-
Lw (dB)

Lw (dB)
Pw [kW]=

Pw [kW]=

103 94
Welle:
Shaft

Welle:
Shaft

größen: siehe größen: siehe 20°


Total

Total

Maßblätter 102 Maßblätter 93


101 92

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 084
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V° = =Volume flow [m3/h] Tip speed u2 = 50 m/s Moment of inertia II==2.05 2 ° 3 2


Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 50 m/s Trägheitsmoment 2,05kg/m
kg m2 V = =Volume flow [m /h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 76 m/s
Umfangsgeschwindigkeit u2 = 76 m/s Moment of inertia I I==2.05
Trägheitsmoment 2,05kg/m
kg m2
3 Temperature t = 20 °C Casing diameter d.i.L.d.i.L.
= 1003 mm mm 3 Temperature
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C
␦ Schachtdurchmesser = 1003 pd =
pd = Dyn. pressure
dyn. Druck [Pa]
[Pa] or x
bzw. 0.1 [kp/m
x 0,1 [kp/m2]] Temperatur t t==20°
␦ 20 C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 1003 mm mm
= 1003
cc ==Flow velocity [m/s] Density = 1.2 kg/m33 Outlet cross section A
A2 == 0,79 m22
0.79 m Density
Dichte == 1,2 kg/m33
1.2 kg/m m22
Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m Austrittsquerschnitt 2 cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Outlet cross section A
Austrittsquerschnitt A2 == 0,79
0.79 m
2

800
BVAXN 12/56/1000/D – n = 950 rpm 1800
BVAXN 12/56/1000/D – n = 1450 rpm
0,89 ␩ = 0,80
710 0,89 ␩ = 0,80 1600
0,86 0,77
0,86 0,77
630 1400
0,81
560 0,81 1250 0,72

pd
0,72 0,76

pd
0,76 0,66
500 0,66 1120
25°

pd
25°

pd
450 1000

(Pa)➞➞
(Pa)➞➞

35°
35° 0,67 Schaufelwinkel
Blade pitch angle

pressure increase 6⌬ptpt[Pa]


pressure increase 6⌬ptpt[Pa]

400 0,67 Blade pitch


Schaufelwinkel 900 20°
angle auf Anfrage
please ask
20°
355 800 30°
30°

TotalTotaldruckerhöhung
TotalTotaldruckerhöhung

315 710 15° 0,57


· 15° 0,57
·
280 630 25°
25°

250 560
20° 0,47
0° 0° 5° 5° 10° 10° 15° 0,47 0° 0° 5° 5° 10° 10° 15° 20°

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000
16 000

18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25
4,5

5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

␩ [m3/s] ➞ ␩ [m3/s] ➞
9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5
5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

c [m/s] ➞ c [m/s] ➞
50

63

80

100

125

160

200

250

315

400

500

630

800
20

25

31,5

40

50

63

80

100

125

160

200

250

315

mitwith duct 2.5


Rohrleitung 2,5DD pd [Pa] ➞ with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞
12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45

50
8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

c [m/s] ➞ c [m/s] ➞
100

125

160

200

250

315

400

500

630

800

1000

1250

1600
40

50

63

80

100

125

160

200

250

315

400

500

630

pd [Pa] ➞ pd [Pa] ➞
free
frei outlet
ausblasend freifree outlet
ausblasend
115

w [dB]
108
Gesamt-Schalleistungspegel Lw [dB]

Total acoustic powerLlevel


Total acoustic power level

=
=

107 5° 114
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

␩· 1000 · 3600
␩· 1000 · 3600

106 113
an der
an der

Gesamt-Schalleistungspegel
15°
power input

10°
power input

5° 105 112
10° 15° 104 35° 111
0° 0°
Leistungsbedarf
Leistungsbedarf

35° 103 30° 110


requirement
requirement

30° 102 25° 109


Max. mögliche 25° Max. mögliche
101 20° 108
Motorbau- Motorbau-

Lw (dB)
Lw (dB)

Pw [kW]=
Pw [kW]=

Welle:
Shaft

100 107
Welle:
Shaft

größen: siehe 20° größen: siehe


Maßblätter 99 Maßblätter 106
98 105

° = Volume flow [m3/h] or


V° = =Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 42 m/s
Umfangsgeschwindigkeit u2 = 42 m/s Moment of inertia II == 3.63
Trägheitsmoment kg m22
3,63 kg/m V = Volumenstrom [m3/h] [m/s]
bzw. [m3/s] Tip speed u2 = 57 m/s
Umfangsgeschwindigkeit u2 = 57 m/s Moment of inertia I I==3.63
Trägheitsmoment kg m22
3,63kg/m
3
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m32]]
0,1 [kp/m Temperaturet =
Temperatur t =20°
␦20 C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 1124 mm mm
= 1124 pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperature
Temperatur t t==20°
␦ 20 C
°C Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 1124 mm mm
= 1124
c ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density == 1,2
Dichte kg/m33
1.2 kg/m Outlet cross section A = 1.0
Austrittsquerschnitt A22 = 1,0 m m22 cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2 kg/m33
1,2 kg/m Outlet cross section A
Austrittsquerschnitt A2 = 1,0 m
= 1.0 m22 2

560
BVAXN 12/56/1120/D – n = 720 rpm 1000
BVAXN 12/56/1120/D – n = 980 rpm
0,89 ␩ = 0,80
500 0,88 ␩ = 0,79 900 0,86 0,77
0,85 0,76
450 800
0,81
0,72
pd

400 0,80 710


0,71 0,76
pd

0,66
0,75
355 0,65 630
25°
pd

25°
pd

315 560
(Pa)➞➞
(Pa)➞➞

35°
0,67
Blade pitch angle
Schaufelwinkel
35°
pt[Pa]

pt[Pa]

280 0,66 Blade pitch angle


Schaufelwinkel 500 20°
6 pt

⌬ pt

20°
pressure increase ⌬

30°
pressure increase 6

250 450
30°
Total Totaldruckerhöhung

TotalTotaldruckerhöhung

224 400 15° 0,57


· 15° 0,56 ·
25°
200 355
25°

180 315 0,47


20° 0° 0° 5° 5° 10° 10° 15° 20°
0° 0° 5° 5° 10° 10° 15° 0,46
18 000

20 000

22 400

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

71 000

25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

␩ [m3/s] ➞ ␩ [m3/s] ➞
5,0

5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

c [m/s] ➞ c [m/s] ➞
16

20

25

31,5

40

50

63

80

100

125

160

200

250

31,5

40

50

63

80

100

125

160

200

250

315

400

500

mitwith duct 2.5


Rohrleitung 2,5DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

c [m/s] ➞ c [m/s] ➞
31,5

40

50

63

80

100

125

160

200

250

315

400

500

63

80

100

125

160

200

250

315

400

500

630

800

1000

pd [Pa] ➞ pd [Pa] ➞
free
frei outlet
ausblasend freifree
ausblasend
outlet
106
Lw [dB]

111
w [dB]
Total acoustic power level

acoustic powerLlevel


=

105 110
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

5° 104 109
␩· 1000 · 3600

␩· 1000 · 3600
an der

an der
LGesamt-Schalleistungspegel

Gesamt-Schalleistungspegel

10° 15°
power input

power input

103 108
10° 15° 35°
102 0° 107
Leistungsbedarf

Leistungsbedarf

35° 101 30° 106



requirement

requirement

30° 100 25° 105


Max. mögliche 25° Max. mögliche
99 20° 104
Motorbau- Motorbau-
w (dB)

Lw (dB)
Pw [kW]=

Pw [kW]=

98 103
Welle:
Shaft

Welle:
Shaft

größen: siehe 20° größen: siehe


Total

Maßblätter 97 Maßblätter 102


96 101

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 085
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V° = =
Volume flow [m3/h] Tip speed u2 = 49 m/s Moment of inertia II==6.25
6,25kg/m
2 V° = Volume flow [m3/h] or [m/s] Tip speed u2 = 64 m/s Moment of inertia I = 6.25 kg/m 2 2
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 49 m/s Trägheitsmoment kg m2 = Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 64 m/s Trägheitsmoment I = 6,25 kg m
pd 3 Temperature
Temperatur t t==20°
20 C
°C Casing diameter d.i.L.d.i.L.
= 1261 mm mm pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C Casing diameter d.i.L. = 1261 mm
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] ␦ Schachtdurchmesser = 1261 pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] ␦
Temperatur t = 20° C3 Schachtdurchmesser d.i.L. = 1261 mm
cc ==Flow velocity [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3
3 Outlet cross section A
Austrittsquerschnitt A2 == 1,25 m22
1.25 m cc ==Flow velocity [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Outlet cross section A
Austrittsquerschnitt A2 == 1.25 m22
Srömungsgeschwindigkeit [m/s] 2 Srömungsgeschwindigkeit [m/s] 2 1,25 m

710
BVAXN 12/56/1250/D – n = 740 rpm 1250
BVAXN 12/56/1250/D – n = 980 rpm
0,89 ␩ = 0,80 0,89 ␩ = 0,80
630 0,86 1120
0,77 0,86 0,77

560 1000
0,81 0,81
0,72

pd
0,72

pd
500 0,76 900
0,66 0,76
0,66
450 800
25°

pd
25°

pd
➞➞

400 35° 710


35°
0,67

(Pa) ➞
Blade pitch
Schaufelwinkel
0,67 Blade pitch angle
(Pa)

Schaufelwinkel
angle
pressure increase 6⌬ptpt[Pa]

increase ⌬∆ pt [Pa]
355 20° 630 20°

30° 30°
315 560
TotalTotaldruckerhöhung

Totaldruckerhöhung
280 15° 0,57 500 15° 0,57 
· ·
25°

Total pressure
250 450 25°

224 0,47 400


0,47
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20° 
25 000

28 000

31 500

35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞

· 6 pt · ∆ pt
Pw = = [kW] Pw = = [kW]
7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

10

11,2

12,5

14

16

18

20

22,4

25
␩ [m3/s] ➞ ␩ [m3/s] ➞
5,6

6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5
c [m/s] ➞ c [m/s] ➞
20

25

31,5

40

50

63

80

100

125

160

200

250

315

40

50

63

80

100

125

160

200

250

315

400

500

630
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45
c [m/s] ➞ c [m/s] ➞
40

50

63

80

100

125

160

200

250

315

400

500

630

80

100

125

160

200

250

315

400

500

630

800

1000

1250
free outlet pd [Pa] ➞ free outlet pd [Pa] ➞
frei ausblasend frei ausblasend
108
Lw [dB]

114

Gesamt-Schalleistungspegel Lw [dB]
=

Total acoustic power level

acoustic power level



5° 107 113
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]


␩· 1000 · 3600

␩· 1000 · 3600

15° 106 112


an der

an der

10°
Gesamt-Schalleistungspegel
power input

15°
power input

105 10° 111


0° 35°
104 0° 35° 110
Leistungsbedarf

30°
Leistungsbedarf
requirement

103 30° 109


requirement

25°
102 25° 108
Max. mögliche 20° Max. mögliche
101 20° 107
Motorbau- Motorbau-
Pw [kW]=

w (dB)

Pw [kW]=

Lw (dB)
Welle:
Shaft

Welle:
Shaft

größen: siehe 100 größen: siehe 106

Total
Maßblätter 99 Maßblätter 105
98 104
L

 Capacity limit for fans for 400°C


 Fans in the screened field may only be used up to 200°C and 300°C
resp.

BVAXN 12/56
Smoke exhaust fan types documented on the
following pages 070+071 may be used for
200/300/°C – 120 MIN
BVAXN 12/56/1120/D - 1450 rpm
BVAXN 12/56/1250/D - 1450 rpm
BVAXN 12/56/1400/D - 740 rpm
BVAXN 12/56/1400/D - 980 rpm
BVAXN 12/56/1600/D - 740 rpm
BVAXN 12/56/1600/D - 980 rpm
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C – 120 MIN 086
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V° = =Volume flow [m3/h] 2 ° = Volume flow [m3/h] or [m/s]


Volumenstrom [mor3/h] bzw. [m3/s] Tip
[m/s] speed u2 = 82 m/s
Umfangsgeschwindigkeit u2 = 82 m/s Moment of inertia I =
Trägheitsmoment I =3.63
3,63kg/m
kg m2 V = Volumenstrom [m3/h] bzw. [m3/s] Tip speed u2 = 95 m/s
Umfangsgeschwindigkeit u2 = 95 m/s Moment of inertia I I==6.25
Trägheitsmoment kg m2 2
6,25kg/m
3 3
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m2]] Temperature
0,1 [kp/m Temperatur tt==20°
20 °C
C ␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 1124 mm mm
= 1124 pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx0.1
bzw. [kp/m2] ] Temperature
0,1[kp/m Temperatur tt==20°
20 °C
C ␦ Schachtdurchmesser
Casing diameter d.i.L. d.i.L.
= 1261 = 1261
mm mm
3 2 3
c
c ==Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Outlet cross section AA2 == 1.0
Austrittsquerschnitt 1,0 m
m2 2
cc ==Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Austrittsquerschnitt
Outlet cross section A A22 == 1.25
1,25 mm22

2240
BVAXN 12/56/1120/D – n = 1450 rpm A1 = 0,68 m2 BVAXN 12/56/1250/D – n = 1450 rpm A1 = 1,07 m2
2800
0,89 ␩ = 0,80 0,89 η = 0,80
2000 2500
0,86 0,77 0,86
0,77
1800 2240
0,81 0,81
0,72

pd

pd
1600 2000 0,72
0,76 0,76
0,66 0,66
1400 1800
25° 25°

pd

pd
1250 1600 7
(Pa)➞➞

(Pa)➞➞
35° 0,6
Blade pitch angle 35°
0,67 Schaufelwinkel
pt[Pa]

pressure increase ∆⌬ptpt[Pa]


Blade pitch angle
1110 20° 1400 20° Schaufelwinkel
pressure increase ∆⌬pt

1000 30° 1250 30°


TotalTotaldruckerhöhung

TotalTotaldruckerhöhung
900 15° 0,57 1120 15°
0,57

800 25°
1000 25°

710 900
0,47
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20°
35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000

45 160 000

50 180 000

56 200 000
[m3/h] ➞ [m3/h] ➞
10

11,2

12,5

14

16

18

20

22,4

25

14

16

18

20

22,4

25
[m3/s] ➞ [m3/s] ➞
10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45
c [m/s] ➞ c [m/s] ➞
63

80

100

125

160

200

250

315

400

500

630

800

56 1000

80

100

125

160

200

250

315

400

500

630

800

56 1000

63 1250
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
14

16

18

20

22,4

25

28

31,5

35,5

40

45

50

16

18

20

22,4

25

28

31,5

35,5

40

45

50
c [m/s] ➞ c [m/s] ➞
125

160

200

250

315

400

500

630

800

1000

1250

1600

2000

160

200

250

315

400

500

630

800

1000

1250

1600

2000

2500
free outlet pd [Pa] ➞ free outlet pd [Pa] ➞
frei ausblasend frei ausblasend
119
Leistungsbedarf an der Welle:

Gesamt-Schalleistungspegel Lw [dB]

Gesamt-Schalleistungspegel Lw [dB]
122
=

Total acoustic power level


Total acoustic power level

· ⌬pt [Pa] =
an der Welle:
Pw [kW] = ␩· 1000 · 3600 =

5° 118 5° 121
Pw [kW] = ␩· 1000 · 3600 =
V̇[m33/h] · ⌬pt [Pa]

·V̇[m33/h] · ⌬pt [Pa]


Pw [kW]= V [m /h] · ⌬pt [Pa]

117
an der

120
an der

␩· 1000 · 3600
␩· 1000 · 3600

15° 10° 15°


power input

10°
power input

116 119
0° 35° 115 0° 35°
118
Leistungsbedarf

/h]
Leistungsbedarf

114 30°
requirement

30° 117
Leistungsbedarf
requirement

25° 25°
[m

113 116
V
·

20° 112 20° 115

Lw (dB)
Lw (dB)

Pw [kW]=
Welle:
Shaft

111
Welle:
Shaft

114
110 113
109 112

° = Volume flow [m3/h] or [m/s]


V° = =
Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 54 m/s
Umfangsgeschwindigkeit u2 = 54 m/s Moment of inertia I I==10.05
Trägheitsmoment 10,05kg/m
2
kg m2 V = Volumenstrom [m3/h] bzw. [m3/s]
Tip speed u2 = 72 m/s
Umfangsgeschwindigkeit u2 = 72 m/s Moment of inertia I =
Trägheitsmoment I =10.05 kg m2 2
10,05kg/m
3 3
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperature
Temperatur t t==20°
␦ 20 C°C Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 1415 mm mm
= 1415 pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. [kp/m2]] Temperature
0,1 [kp/m Temperatur tt==20°
20 °C
C3 ␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 1415 mm mm
= 1415
kg/m33 22
cc = =Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Density
Dichte == 1,2
1.2 kg/m Outlet cross section A = 1.57
Austrittsquerschnitt A2 = 1,57 m m
2 c = Strömungsgeschwindigkeit [m/s] Density
c = Flow velocity [m/s] Dichte == 1.2
1,2 kg/m
kg/m3 Outlet cross section A
Austrittsquerschnitt A2 = 1,57m
= 1.57 m22 2

900
BVAXN 12/56/1400/D – n = 740 rpm A1 = 1,07 m2
1600
BVAXN 12/56/1400/D – n = 980 rpm A1 = 1,07 m2

0,89 ␩ = 0,80 0,89 ␩ = 0,80


800 0,86
1400 0,86 0,77
0,77

710 1250
0,81 0,81
0,72
pd

0,72
pd

630 0,76 1120 0,76


0,66 0,66

560 1000 25°


25°
pd
pd
➞➞

➞➞

500 35° 900 35°


Blade pitch angle
0,67
Blade pitch angle
Schaufelwinkel 0,67 Schaufelwinkel
(Pa)

(Pa)
pressure increase ∆⌬ptpt[Pa]
pressure increase ∆⌬ptpt[Pa]

450 20° 800 20°

30° 30°
400 710
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung

355 15° 0,57 630 15° 0,57

25° 25°
315 560

280 0,47 500 0,47


0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20°
50 000

56 000

63 000

71000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000

45 160 000

50 180 000

56 200 000
35 500

40 000

45 000

50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000

[m3/h] ➞ [m3/h] ➞
14

16

18

20

22,4

25
10

11,2

12,5

14

16

18

20

22,4

25

[m3/s] ➞ [m3/s] ➞
9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5
6,3

7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

c [m/s] ➞ c [m/s] ➞
50

63

80

100

125

160

200

250

315

400

500

630

800
25

31,5

40

50

63

80

100

125

160

200

250

315

400

with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

45

50
9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

c [m/s] ➞ c [m/s] ➞
100

125

160

200

250

315

400

500

630

800

1000

1250

1600
50

63

80

100

125

160

200

250

315

400

500

630

800

pd [Pa] ➞ free outlet pd [Pa] ➞


free
frei outlet
ausblasend frei ausblasend
117
Gesamt-Schalleistungspegel Lw [dB]

112
Gesamt-Schalleistungspegel Lw [dB]

an der Welle:
an der Welle:

Pw [kW] = ␩· 1000 · 3600 = =

Total acoustic power level


Total acoustic power level

5° 5°
111 116
Pw [kW] = ␩· 1000 · 3600 =
· V̇[m33/h] · ⌬pt [Pa]

· V̇[m33/h] · ⌬pt [Pa]


⌬pt [Pa]
Pw [kW]= V [m /h] · ⌬pt [Pa]

110 115
an der

an der

10° 15° 10° 15°


␩· 1000 · 3600
␩· 1000 · 3600

power input
power input

35° 109 114


0° 35°
108 0° 113
·
Leistungsbedarf

Leistungsbedarf

30°
/h]

30°
Leistungsbedarf
Leistungsbedarf

107 112
requirement
requirement

25° 25°
[m

106 111
V

20° 105 20° 110


Pw [kW]=

Lw (dB)
Lw (dB)
Welle:

Welle:
Shaft

109
Shaft

104
103 108
102 107
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C – 120 MIN 087
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V° = Volume flow [m3/h] or [m/s] Tip speed u2 = 61 m/s Moment of inertia I = 17.25 kg/m2 2 V° = Volume flow [m3/h] or [m/s] Tip speed u2 = 81 m/s
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 61 m/s Trägheitsmoment I = 17,25 kg m = Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 81 m/s Moment of inertia I I==17.25
Trägheitsmoment kg m22
17,25kg/m
pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C ␦ Casing diameter d.i.L. = 1587 mm pd
pd == Dyn.
dyn. pressure [Pa] or xx 0.1
0,1 [kp/m
3
[kp/m2]] Temperature
Temperatur tt==20°
20 °C
C3 ␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 1587 mm mm
= 1587
pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] Temperatur t = 20° C3 Schachtdurchmesser d.i.L. = 1587 2
mm Druck [Pa] bzw.
Density = 1.2 kg/m Outlet cross section AA2 ==1.98
cc ==Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m3 Austrittsquerschnitt 1,98mm2 2
cc = =Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Austrittsquerschnitt
Outlet cross section A A2 == 0,31 m22
1,98 m 2

1120
BVAXN 12/56/1600/D – n = 740 rpm A1 = 1,31 m2
2000
BVAXN 12/56/1600/D – n = 980 rpm A1 = 1,31 m2

0,89 ␩ = 0,80
0,89 ␩ = 0,80
1000 0,86 0,77 1800
0,86 0,77
900 1600
0,81
0,72 0,81

pd
0,72

pd
800 0,76 1400
0,66 0,76
0,66
710 25° 1250

pd
25°

pd
630 1120
(Pa)➞➞

(Pa)➞➞
35°
0,67
Blade pitch angle
Schaufelwinkel 35°
0,67
Blade pitch angle
Schaufelwinkel
20°

pressure increase ∆⌬ptpt[Pa]


pressure increase ∆⌬ptpt[Pa]

560 1000 20°


30°
500 900 30°

TotalTotaldruckerhöhung
TotalTotaldruckerhöhung

450 15° 0,57 800 15° 0,57


25°
400 710 25°

355 0,47 630


0° 0° 5° 5° 10° 10° 15° 20° 0,47
0° 0° 5° 5° 10° 10° 15° 20°

71000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000

45 160 000

50 180 000

56 200 000

63 224 000

71 250 000

80 280 000
50 000

56 000

63 000

71 000

80 000

90 000

28 100 000

31,5 112 000

35,5 125 000

40 140 000

45 160 000

50 180 000

56 200 000

[m3/h] ➞ [m3/h] ➞

20

22,4

25
14

16

18

20

22,4

25

[m3/s] ➞ [m3/s] ➞

10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40
7,1

8,0

9,0

10

11,2

12,5

14

16

18

20

22,4

25

28

c [m/s] ➞ c [m/s] ➞
63

80

100

125

160

200

250

315

400

500

630

800

56 1000
31,5

40

50

63

80

100

125

160

200

250

315

400

500

with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
14

16

18

20

22,4

25

28

31,5

35,5

40

45

50
10

11,2

12,5

14

16

18

20

22,4

25

28

31,5

35,5

40

c [m/s] ➞ c [m/s] ➞
125

160

200

250

315

400

500

630

800

1000

1250

1600

2000
63

80

100

125

160

200

250

315

400

500

630

800

1000

free outlet pd [Pa] ➞ pd [Pa] ➞


frei ausblasend frei ausblasend
free outlet
120
requirement an der Welle:

Gesamt-Schalleistungspegel Lw [dB]
114
Leistungsbedarf an der Welle:

Gesamt-Schalleistungspegel Lw [dB]
Total acoustic power level


Pw [kW]= V· [m3/h] · ⌬pt [Pa] =

Total acoustic power level


Pw [kW]= V [m /h] · ⌬pt [Pa] =


Pw [kW] = ␩· 1000 · 3600 =
Pw [kW] = ␩· 1000 · 3600 =

113 119
V̇[m33/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

15° 112 118


an der

10°
an der

␩· 1000 · 3600
␩· 1000 · 3600

Shaft power input

15°
Shaft power input

111 10° 117


0° 35°
110 0° 35° 116
30°
Leistungsbedarf

Leistungsbedarf

Leistungsbedarf

115
requirement

25° 109 30°


108 25° 114
·

20° 107 113


20°
Lw (dB)

Lw (dB)
106 112
Welle:

Welle:

105 111
104 110

BVAXN 12/56

Please look for further types of Smoke Exhaust Fans


for 400°C – 120 min
without cooling fan
on pages 082 and 083
BVAXN 8/56/1400/D - 740 rpm / max. motor output 22 kW
BVAXN 8/56/1400/D - 980 rpm / max. motor output 37 kW
BVAXN 8/56/1600/D - 740 rpm / max. motor output 22 kW
– 088 –
Unit price Total
Item
Qty. Description
No.
2 2

Axial Smoke Exhaust Fan – BVAXN Series, Type M-D


for the extraction of smoke fumes of max. 200°C/120 min.
tested as per EN 12101-T3 (Munich Technical University)
approval no. Z-78.1-18

Airflow direction: motor in outlet


Direct-drive type

Appropriate for installation in- and outside of fire-zone.

Consisting of
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box

Surface protection:
• Polyester powder coating, colour: RAL 7030
• as of nominal size 1120: with full paint finish, colour: RAL7030
or • Hot-dip galvanized

Aluminium impeller, blade pitch steplessly adjustable when


fan is at rest, directly mounted on motor shaft end.

Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Technical data:
Volume flow m3/h
Temperature / humidity °C/%RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level LW dB
Efficiency %
Power input requirement kW

Three-phase motor
single-speed
or Dahlander pole-changing type
or pole-changing type with separate windings

Motor speed rpm


Motor output kW
Current consumption A
Voltage V
Frequency Hz
Protection class (IP)
Type B/V
Size

Weight: fan with accessories approx. kg


Manufacturer: TLT-Turbo GmbH

Type: BVAXN 12/56/..........M-D


Carryover
– 089 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Accessory equipment

• Galvanised fan
• Fan with special coating
• Extension casing without inspection hatch
• Inspection hatch
• Bellmouth inlet with flange
• Wire guard on bellmouth side
• Wire guard on extension casing (motor side)
• Flexible connector, inlet side*
• Flexible connector, outlet side*
• Matching flange inlet side*
• Matching flange outlet side*
• Angular wall ring with brackets*
• Set of mounting feet (2 pcs.)*
• Set of spring-type antivibration mounts*
• Brackets for vertical fan installation
• Diffuser with interior core*
• Round silencer, TSR type*

BVAXN 12/56

Note:

Please see our Installation, Operating and Maintenance


Instructions that are available on request.

* Loosely supplied
– 090 –
Unit price Total
Item
Qty. Description
No.
2 2

Axial Smoke Exhaust Fan – BVAXN Series, Type M-D


for the extraction of smoke fumes of max. 300°C/120 min.
tested as per EN 12101-T3 (Munich Technical University)
approval no. Z-78.1-20

Airflow direction: motor in outlet


Direct-drive type

Appropriate for installation in- and outside of fire-zone.

Consisting of:
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box

Surface protection:
• Polyester powder coating, colour: RAL 7030
• as of nominal size 1120: with full paint finish, colour: RAL 7030
or • Hot-dip galvanized

Aluminium impeller, blade pitch steplessly adjustable when


fan is at rest, directly mounted on motor shaft end.

Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)

Specifications
Volume flow m3/h
Temperature / humidity °C /% RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level LW dB
Efficiency %
Power input requirement kW
Three-phase motor
single-speed
or Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Current consumption A
Voltage V
Frequency Hz
Protection class (IP)
Type B/V
Size
Weight: fan with accessories approx. kg
Manufacturer: TLT-Turbo GmbH

Type: BVAXN 12/56/..........M-D

Carryover
– 091 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Accessory equipment:

• Galvanised fan

• Fan with special coating

• Extension casing without inspection hatch

• Inspection hatch

• Bellmouth inlet with flange

• Wire guard on bellmouth side

• Wire guard on extension casing (motor side)

• Flexible connector, inlet side*

• Flexible connector, outlet side*

• Matching flange inlet side*

• Matching flange outlet side*

• Angular wall ring with brackets*

• Set of mounting feet (2 pcs.)*

• Set of spring-type antivibration mounts*

• Brackets for vertical fan installation

• Diffuser with interior core*

• Round silencer, TSR type*

BVAXN 12/56

Note:

Please see our Installation, Operating and Maintenance


Instructions that are available on request .

* Loosely supplied
– 092 –
Unit price Total
Item
Qty. Description
No.
2 2

Axial Smoke Exhaust Fan – BVAXN Series, Type M-D

for the extraction of smoke fumes of max. 400°C/120 min.


tested as per EN 12101-T3 (Munich Technical University)
approval no. Z-78.1-21

Airflow direction: motor in outlet


Direct-drive type

Appropriate for installation in- and outside of fire-zone.

Consisting of:
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box

Surface protection:
Polyester powder coating, colour: RAL 7030
as of nominal size 1120: with full paint finish, colour: RAL7030
or Hot-dip galvanized

Aluminium impeller, blade pitch not adjustable, directly


mounted on motor shaft end.

Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Technical data:
Volume flow m3/h
Temperature/air humidity C/% RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level Lw dB
Wfficiency %
Power input requirement kW

Three-phase motor:
single speed
or Dahlander pole-changing type
or pole-changing type with separate windings

Motor speed rpm


Motor output kW
Current consumption A
Voltage V
Frequency Hz
Protection class (IP)
Type B/V
Size
Weight: fan with accessories approx. kg
Manufacturer: TLT-Turbo GmbH

Type: BVAXN 12/56/..........M-D

Carryover
– 093 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Accessory equipment:

• Galvanised fan

• Fan with special coating

• Extension casing without inspection hatch

• Inspection hatch

• Bellmouth inlet with flange

• Wire guard on bellmouth side

• Wire guard on extension casing (motor side)

• Flexible connector, inlet side*

• Flexible connector, outlet side*

• Matching flange inlet side*

• Matching flange outlet side*

• Angular wall ring with brackets*

• Set of mounting feet (2 pcs.)*

• Set of spring-type antivibration mounts*

• Brackets for vertical fan installation

• Diffuser with interior core*

• Round silencer, TSR type*

BVAXN 12/56

Note:

Please see our Installation, Operating and Maintenance


Instructions that are available on request .

* Loosely supplied
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C - 120 MIN 095
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Important! This fan series is available only with the motor


outputs stated in our price lists.
b 1*
b2**
L

Øk
i.d.

Ød1

ØD

For dimensions for external air


connection please see page 097
In instances where the fan is installed
inside the fire zone, there will be no
cooling air fan. In this case the installer
has to provide an insulated duct with
Cooling air fan required! cooling air fan. This is to be mounted
outside the fire zone. Please ask for
For quantities of cooling air needed please see page 107. quantities of cooling air needed.

max. Weight
approx.
Size i.d. motor kg (without
size motor)

BVAXN 8/56

500

700

920

1210

Dimensional and design changes reserved. blade pitch angle 0 to 15° Dimensions in mm
blade pitch angle 16 to 35°
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
600°C – 120 MIN 096
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Wire guard Bellmouth inlet Mounting feet


inlet side with flange i.d.1
øk

Flexible connector Angular wall ring Matching flange Spring-type AV mounts

appr. 60
i.d.3
i.d.3
i.d.2

appr. 80
Installation
length

Please mount Flexible Connector correctly and watch installation length.

Size ØD1 i.d.1 c H a4 a5 b b1 z x d3 i.d.2 i.d.3 Øk ØD zxd e f

500 708 509 98 375 735 705 460 380 5x12 506 507 541 571 12x9,5 80 50

630 875 640 95 470 933 893 550 470 5x12 637 638 674 712 16x11,5 100 70

710 972 717 103 525 990 950 620 530 5x12 714 715 751 785 16x11,5 100 70

800 1081 801 115 585 1125 1085 730 640 5x14 800 801 837 875 24x11,5 100 70

900 1214 898 130 655 1198 1154 730 640 5x14 897 898 934 972 24x11,5 100 70

1000 1351 1009 145 730 1342 1296 830 740 5x14 1006 1007 1043 1081 24x11,5 100 70

1120 1470 1130 160 760 1487 1441 920 820 5x14 1133 1134 1174 1214 24x11,5 110 90

1250 1677 1263 185 855 1837 1791 1030 930 5x14 1270 1271 1311 1351 24x11,5 110 90

1400 1870 1417 210 930 2087 2041 1140 1040 5x14 1424 1425 1465 1505 24x11,5 130 100

1600 2087 1587 210 1020 2342 2296 1350 1230 5x18 1596 1597 1637 1677 32x11,5 130 100

Dimensional and design changes reserved. *All accessories except for mounting feet and Dimensions in mm
extension casings will be supplied loosely.
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 097
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Mounting brackets for vertical installation (direct-driven fans only) Diffuser with interior core

E F

i. d2
i.d.
Y
H

H1
L1

External air connection (fresh air 500- 800- 1000- 1250-


d Size
or exhaust air resp.) 710 900 1120 1600
x

a 102 102 102 142


b1
X

b 102 202 252 317

w2

Frame – external air connection


w2 b3
a3 136 136 136 176
A

b3 136 236 286 351


 A1

b a1 162 162 162 377

a1
b1 162 262 312 202
a3
a

ta – – – 88
ød
ta

xb · t – – – 1 x 125
°
45 tb – 118 143 113
b  tb xb·t w2 13 13 13 13
d 10 10 10 10

Duct with self- L6 Outlet cone L4 Outlet cone L2


activating damper with self-activating with wire guard
damper + wire guard
Øk

L5
zxd Wire guard L3
BVAXN 8/56
Size  A  A1 b Ø d i.d. Øk ØD zxd H H1 X Y Z i.d.2 Ø d3 Ø k2 Ø D2 z x d2 L1 L2 L3 L4 L5 L6

500 657 705 80 11,5 504 541 571 12x9,5 450 225 391 379 177 634 282 674 712 16x11,5 600 280 60 450 305 355

630 852 900 90 11,5 634 674 712 16x11,5 572 286 462 458 271 797 355 837 875 24x11,5 750 330 70 500 375 400

710 929 977 100 11,5 711 751 789 16x11,5 610 305 404 535 285 894 397 934 972 24x11,5 850 350 70 630 420 450

800 1015 1063 100 11,5 797 837 875 24x11,5 700 350 457 618 337 1003 446 1043 1081 24x11,5 950 520 200 710 474 500

900 1112 1160 100 11,5 894 934 972 24x11,5 746 373 499 646 353 1124 502 1174 1254 24x11,5 1060 585 225 800 541 560

1000 1221 1269 100 13,5 1003 1043 1081 24x11,5 830 415 551 714 411 1261 562 1311 1391 24x11,5 1200 640 240 900 612 630

1120 1374 1434 120 13,5 1124 1174 1254 24x11,5 570 635 935 345 1415 630 1465 1545 24x11,5 1340 730 250 1000 678 710

1250 1511 1571 120 13,5 1261 1311 1391 24x11,5 400 700 1168 445 1587 710 1637 1717 32x11,5 1510 810 250 1120 761 800

1400 1665 1725 120 13,5 1415 1465 1545 24x11,5 700 785 1108 845 1780 789 1830 1910 32x11,5 1690 800 160 1250 848 900

1600 1837 1897 120 13,5 1587 1637 1717 32x11,5 600 850 1235 905 1997 888 2047 2167 32x11,5 1900 900 180 1400 940 1000

Dimensional and design changes reserved.  Sizes 500+630 = 30° *please see page 096 Dimensions in mm
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 098
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Acoustic level Starting from this value, the A-weigh- ning, respectively. The values given
ted acoustic power level LWA and the were taken from measurements as
relative acoustic power level LWrel. per EN 25136 (formerly DIN 45 635,
The total acoustic power level Part 9) duct testing method.
can be determined using the tables
LW.Vent. (in dB) of an axial smoke ex- below. These values are available as
haust fan can be obtained directly the acoustic power emitted into the
from the characteristic data sheets for duct and as the acoustic power emit-
each operating point. ted from the fan inlet or outlet ope-

1. Acousting power level emitted into the duct Portion Portion 1.2 at mid-octave frequency [Hz]
Size rpm 1.1
The level of acoustic power an axial smoke exhaust fan 63 125 250 500 1000 2000 4000 8000
emits into the ducting is used for calculating the sound po- 500 675 9 5 3 9 12 16 18 21 31
wer characteristics of downstream systems, e.g., silencers. 900 8 6 4 9 10 13 17 18 27
1400 5 7 8 5 9 10 14 16 19
The levels are calculated as follows: 2800 2 8 10 11 7 8 8 12 14
630 710 8 6 4 9 10 13 17 18 27
Lwvent. [dB] = total acoustic power emitted by the fan, 920 6 6 4 9 9 11 15 16 22
(please see respective characteristic curve 1410 4 7 9 6 9 9 12 15 16
710 710 6 6 4 9 10 12 16 17 24
sheets) 950 6 7 4 10 9 10 14 16 19
1450 4 7 9 6 10 8 10 14 15
LwA vent. [dB] = A-weighted acoustic power level, according 800 720 6 6 4 10 10 11 15 16 22
to the equation 960 5 7 5 10 9 2 13 15 18
1460 3 8 9 6 10 8 10 14 15
LwA vent. = Lwvent. – portion 1.1 [dB] 900 720 6 6 4 10 9 10 14 16 20
960 5 7 5 10 10 9 12 15 18
Lwrel vent. [dB] = relative acoustic power level as expressed 1460 3 8 9 6 11 8 9 13 14
by the equation 1000 720 5 6 5 10 10 9 13 15 18
970 4 7 5 10 10 8 11 15 15
Lwrel vent. = Lwvent. – portion 1.2 [dB] 1460 3 8 10 7 12 8 8 12 14
1120 730 5 7 5 11 10 9 12 15 17
980 4 7 5 11 11 8 10 14 15
1250 740 4 7 5 11 10 8 11 15 15
980 3 8 6 11 12 8 9 13 14
2. Acoustic power emitted from the fan inlet or outlet 1400 740 4 7 5 12 10 8 10 14 15
opening 980 3 8 6 11 12 8 8 12 14
1600 740 3 7 6 12 11 8 9 13 14
To determine the sound levels at a given installation site, 980 3 8 6 12 13 8 8 11 14
it is usually necessary to know the level of acoustic power
emitted from the fan’s inlet or outlet opening. The adjacent Size rpm
Portion Portion 2.2 at mid-octave frequency [Hz]
2.1
tables are based on the outlet reflection pattern assumed 63 125 250 500 1000 2000 4000 8000
in VDI 2081, Case 2. 500 675 10 16 9 11 12 16 18 21 31
900 8 17 9 10 10 13 17 18 27
LwA op. [dB] = A-weighted level of acoustic power emitted from 1400 5 18 13 7 9 10 14 16 19
the fan’s opening, expressed by the equation 2800 3 19 15 13 7 8 8 12 14
630 710 8 15 8 10 10 13 17 18 27
LwA op. = Lwvent. – portion 2.1 [dB] 920 7 15 8 10 10 13 17 18 27
1410 4 16 12 7 9 9 12 15 16
Lwrel op. = relative level of acoustic power emitted from the 710 710 7 14 8 10 10 12 16 17 24
fan’s opening, expressed by the equation 950 6 14 8 10 9 10 14 16 19
1450 4 15 12 7 10 8 10 14 15
Lwrel op. = Lwvent. – portion 2.2 [dB] 800 720 7 13 7 10 10 11 15 16 22
960 5 14 7 10 9 9 13 15 18
1460 3 15 12 7 10 8 10 14 15
900 720 6 12 7 10 9 10 14 16 20
960 5 13 7 10 10 9 12 15 16
1460 3 14 11 7 11 8 9 13 14
1000 720 5 12 7 10 10 9 13 15 18
970 4 12 7 11 10 8 11 15 15
1460 3 13 11 7 12 8 8 12 14
1120 730 5 11 6 11 10 9 12 15 17
980 4 12 7 11 11 8 10 14 15
1250 740 4 11 6 11 10 8 11 15 15
980 3 11 6 11 12 8 9 13 14
1400 740 4 10 6 12 10 8 10 14 15
980 3 11 6 11 12 8 8 12 14
1600 740 3 10 6 12 11 8 9 13 14
980 3 11 6 12 13 8 8 11 14

Note:
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above
spreadsheets.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 8/56 600°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 099
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

500 1000 0,75 2,2 90 B14 160 800 750 0,75 2,3 100 B14 160
1500 1,1 2,6 90 B14 160 1,1 3,28 100 B14 160
1,5 3,5 90 B14 160 1,5 4,2 112 B14 160
3000 4,5 8,5 112 B14 160 2,2 5,6 132 B14 300
1000/500 0,75/0,13 2,8/0,97 90 B14 160 1000 1,5 4,3 100 B14 160
1500/750 1,0/0,25 2,4/1,0 90 B14 160 2,2 5,3 112 B14 160
1,3/0,35 3,6/1,55 90 B14 160 3,0 6,3 132 B14 300
1500/1000 1,3/0,4 3,4/1,38 90 B14 160 4,0 8,6 132 B14 300
3000/1500 4,1/1,1 8,1/2,2 112 B14 160 1500 4,0 8,3 112 B14 160
5,5 11 132 B14 300
630 750 0,55 1,82 90 B14 160
7,5 15 132 B14 300
0,75 2,3 100 B14 160
11 21 160 B14 300
1000 0,75 2,2 90 B14 160
15 28,5 160 B14 300
1,1 3,2 90 B14 160
1000/500 1,2/0,24 3,15/2,1 100 B14 160
1,5 4,3 100 B14 160
2,0/0,33 4,6/2,4 112 B14 160
1500 1,5 3,5 90 B14 160
3,2/0,7 6,8/3,8 132 B14 300
2,2 5,0 100 B14 160
4,4/1,0 9,0/4,5 132 B14 300
3,0 7,0 100 B14 160
1500/750 5,0/1,30 10,7/4,2 132 B14 300
4,0 8,3 112 B14 160
6,8/1,70 14,3/5,2 132 B14 300
1000/500 0,75/0,13 2,8/0,97 90 B14 160
10/3,0 22,3/9,7 160 B14 300
1,2/0,24 3,15/2,1 100 B14 160
14/3,5 29,5/11,8 160 B14 300
2,0/0,33 4,6/2,4 112 B14 160
1500/1000 4,2/1,25 9,0/3,1 132 B14 300
1500/750 2,0/0,45 4,5/1,8 100 B14 160
5,5/1,65 11,2/3,7 132 B14 300
2,5/0,55 5,8/2,1 100 B14 160
9,0/3,0 18/7,1 160 B14 300
3,7/0,9 9,2/3,6 112 B14 160
12/3,5 24/9,5 160 B14 300
1500/1000 2,4/0,75 5,7/2,95 100 B14 160
14/4,5 26,5/11,1 180 B14 350
3,0/0,9 7,0/2,3 112 B14 160
4,2/1,25 9,0/3,1 132 B14 250 900 750 1,1 3,28 100 B14 160
1,5 4,2 112 B14 160
710 750 0,55 1,82 90 B14 160
2,2 5,6 132 B14 300
0,75 2,3 100 B14 160
3,0 7,5 132 B14 300
1,1 3,28 100 B14 160
1000 2,2 5,3 112 B14 160
1000 0,75 2,2 90 B14 160
3,0 6,3 132 B14 300
1,1 3,2 90 B14 160
4,0 8,6 132 B14 300
1,5 4,3 100 B14 160
BVAXN 8/56
5,5 11,5 132 B14 300
2,2 5,3 112 B14 160
7,5 15,8 160 B14 300
3,0 6,3 132 B14 300
1500 7,5 15 132 B14 300
1500 2,2 5,0 100 B14 160
11 21 160 B14 300
3,0 7,0 100 B14 160
15 28,5 160 B14 300
4,0 8,3 112 B14 160
1500 18,5 34,5 180 B14 350
5,5 11 132 B14 300
22 41 180 B14 350
7,5 15 132 B14 300
30 55 200 B14 350
1000/500 1,2/0,24 3,15/2,1 100 B14 160
1000/500 2,0/0,33 4,6/1,6 112 B14 160
2,0/0,33 4,6/2,4 112 B14 160
3,2/0,7 6,8/3,8 132 B14 300
1500/750 2,5/0,6 5,8/2,1 100 B14 160
4,4/1,0 9,9/4,5 132 B14 300
3,7/0,9 9,2/3,6 112 B14 160
6,2/1,3 13,3/3,6 160 B14 300
5,0/1,3 10,7/4,2 132 B14 300
8,4/1,8 17,1/4,8 160 B14 300
6,8/1,7 14,3/5,2 132 B14 300
1500/750 6,8/1,7 14,3/5,2 132 B14 300
1500/1000 2,4/0,75 5,7/2,95 100 B14 160
10/3,0 22,3/9,7 160 B14 300
3,0/0,9 7,0/2,3 112 B14 160
4,2/1,25 9,0/3,1 132 B14 300
 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
5,5/1,65 11,2/3,7 132 B14 300
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 8/56 600°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 100
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

900 1500/750 14/3,5 29,5/11,8 160 B14 300 1250 750 5,5 13 160 B14 300
16/4,0 30/13,1 180 B14 350 7,5 17,2 160 B14 300
20/5,0 39/13,8 180 B14 350 11 23 180 B14 350
28/7,0 52/15,2 200 B14 350 15 32,5 200 B14 350
1500/1000 9,0/3,0 18/7,1 160 B14 300 18,5 39 225 B14 450
12/3,5 24/9,5 160 B14 300 1000 11 22,5 160 B14 300
14/4,5 26,5/11,1 180 B14 350 15 30,5 180 B14 350
16,5/5,5 32/11,8 180 B14 350 22 44 200 B14 350
20/7,0 35/13,7 200 B14 350 30 58 225 B14 450
28/9,0 47,5/18,6 200 B14 350 37 74 250 B14 550
1000/500 12,5/3,0 24/7,5 180 B14 350
1000 1500 11 21 160 B14 300
20/4,5 38,5/13 200 B14 350
15 28,5 160 B14 300
22/5,0 41/13,3 225 B14 450
18,5 34,5 180 B14 350
27/6,0 51/18 225 B14 450
22 41 180 B14 350
30/7,0 58/19 250 B14 550
30 55 200 B14 350
1000/500 4,4/1,0 9,0/4,5 132 B14 300 1400 750 7,5 17,2 160 B14 350
6,2/1,3 13,3/3,6 160 B14 300 11 23 180 B14 350
8,4/1,8 17,1/4,8 160 B14 300 15 32,5 200 B14 350
12,5/3,0 24/7,5 180 B14 350 18,5 39 225 B14 450
1500/750 10/3,0 22,3/9,7 160 B14 300 22 47,5 225 B14 450
14/3,5 29,5/11,8 160 B14 300 30 60 250 B14 550
16/4,0 30/13,1 180 B14 350 1000 22 44 200 B14 350
20/5,0 39/13,8 180 B14 350 30 58 225 B14 450
28/7,0 52/15,2 200 B14 350 37 74 250 B14 550
1500/1000 12/3,5 24/9,5 160 B14 300 45 81 280 B14 550
14/4,5 26,5/11,1 180 B14 350 55 99 280 B14 550
16,5/5,5 32/11,8 180 B14 350 1000/500 20/4,5 38,5/13 200 B14 350
20//7,0 35/13,7 200 B14 350 22/5,0 41,1/13,3 225 B14 450
26/9,0 47,5/18,6 200 B14 350 27/6,0 51/18 225 B14 450
750 2,2 5,6 132 B14 300 30/7,0 58/19 250 B14 550
3,0 7,5 132 B14 300 1000/500 40/8,0 74/24 280 B14 550
4,0 9,25 180 B14 300 48/9,5 88/28 280 B14 550
5,5 13 160 B14 300
1600 750 15 32,5 200 B14 350
1000 4,0 8,6 132 B14 300
18,5 39 225 B14 450
5,5 11,5 132 B14 300
22 47,5 225 B14 450
7,5 15,8 160 B14 300
30 60 250 B14 550
11 22,5 160 B14 300
37 73 280 B14 550
15 30,5 180 B14 350
45 88 280 B14 550
1120 750 3,0 7,5 132 B14 300
4,0 9,25 160 B14 300
5,5 13 160 B14 300
7,5 17,2 160 B14 300
11 23 180 B14 350
1000 7,5 15,8 160 B14 300
11 22,5 160 B14 300
15 30,5 180 B14 350
22 44 200 B14 350
8,4/1,8 17,1/4,8 160 B14 300
12,5/3,0 24/7,5 180 B14 350  Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
20/4,5 38,5/13 200 B14 350 Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 101
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 24 m/s Moment of inertia I = 504 kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 37 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 450 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 504 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2

rpm rpm


Total pressure increase ⌬ pt (Pa)

Total pressure increase ⌬ pt (Pa)


Blade
Blade
pitch
pitch
angle
angle

with duct with duct


2.5 D 2.5 D
=
=

5° 15°
5° 15°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

10° 20°
␩· 1000 · 3600
␩· 1000 · 3600

25° 20°
30° 10° 25°

Total acoustic power


Total acoustic power

30°
Shaft power input
Shaft power input

35°
35°
requirement
requirement

level Lw (dB)
level Lw (dB)

Pw [kW]=
Pw [kW]=

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 76 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 23 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 504 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2

rpm rpm

Don’t design
in rastered
area


Total pressure increase ⌬ pt (Pa)

Total pressure increase ⌬ pt (Pa)

BVAXN 8/56
pd

Blade Blade
pitch pitch
angle angle

with duct with duct


2.5 D 2.5 D


=

15° 5°
10° 15°
V̇[m3/h] · ⌬pt [Pa]

20° 25°
V̇[m3/h] · ⌬pt [Pa]
␩· 1000 · 3600

␩· 1000 · 3600

10° 20°
30° 25°
30°
Total acoustic power
Total acoustic power
Shaft power input

Shaft power input

35°
35°
requirement

requirement

level Lw (dB)
level Lw (dB)
Pw [kW]=

Pw [kW]=

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 102
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 30 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 47 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 634mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.31 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m 2
0,31

rpm rpm


Total pressure increase ⌬ pt (Pa)

Total pressure increase ⌬ pt (Pa)


Blade
Blade pitch
pitch angle angle

with duct with duct


2.5 D 2.5 D
=


=

15° 5°
15°
V̇[m3/h] · ⌬pt [Pa]

20°
V̇[m3/h] · ⌬pt [Pa]
␩· 1000 · 3600

25° 20°
␩· 1000 · 3600

10° 25°
10°
Total acoustic power

Total acoustic power


30° 30°
Shaft power input

Shaft power input

35°
35°
requirement

requirement
level Lw (dB)

level Lw (dB)
Pw [kW]=

Pw [kW]=

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 26 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 35 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 711 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 711 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m2

rpm rpm
➞Total pressure increase ⌬ pt (Pa)

➞ Total pressure ⌬ pt (Pa)

Blade
pitch
angle Blade
pitch angle

with duct with duct


2.5 D 2.5 D


=

15° 5° 15°
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

10° 20° 10° 20° 25°


␩· 1000 · 3600

␩· 1000 · 3600

25°
30° 30°
Total acoustic power
Total acoustic power
Shaft power input

Shaft power input

35°
35°
requirement

requirement

level Lw (dB)
level Lw (dB)
Pw [kW]=

Pw [kW]=

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 103
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 54 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 30 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 711 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 797 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.5 m2

rpm rpm


Total pressure increase ⌬ pt (Pa)


Total pressure increase ⌬ pt (Pa)

Blade Blade
pitch pitch
angle angle

with duct with duct


2.5 D 2.5 D

5° 15° 20° 15°


=
=

25° 5°
10° 20°
25°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

30° 10°
␩· 1000 · 3600
␩· 1000 · 3600

35° 30°
Total acoustic power

Total acoustic power


Shaft power input
Shaft power input

35°
requirement
requirement

level Lw (dB)

level Lw (dB)
Pw [kW]=
Pw [kW]=

V= Volume flow (m3/h) resp. m/s) Tip speed U2=40 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 61 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C Casing diameter d.i.L. = 797 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 797 mm
␦ Outlet cross section A2 = 0.5 m2
c = Flow velocity (m/s) Density = 1.2 kg/m3 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.5 m2

rpm rpm

Total pressure increase ⌬ pt (Pa)


Total pressure increase ⌬ pt (Pa)

BVAXN 8/56

Blade
Blade pitch
pitch angle angle

with duct with duct


2.5 D 2.5 D

5° 15°
=


20° 15°
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

10° 25°
␩· 1000 · 3600

␩· 1000 · 3600

30° 25°
10° 20°
Total acoustic power
Total acoustic power

30°
Shaft power input

Shaft power input

35° 35°
requirement

requirement

level Lw (dB)
level Lw (dB)
Pw [kW]=

Pw [kW]=

* rounded to standard values. For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 104
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 34 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 45 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 894 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 894 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.63 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.63 m2

rpm rpm


Total pressure increase ⌬ pt (Pa)


Total pressure increase ⌬ pt (Pa)

Blade
pitch
angle Blade
pitch
angle

with duct with duct


2.5 D 2.5 D

5° 15°
=

5° 15°
20° 20° 25°
V̇[m3/h] · ⌬pt [Pa]

10°
V̇[m3/h] · ⌬pt [Pa]
␩· 1000 · 3600

␩· 1000 · 3600

10° 25° 30°


30°

Total acoustic power


Total acoustic power
Shaft power input

Shaft power input

35°
35°
requirement

requirement

level Lw (dB)
level Lw (dB)
Pw [kW]=

Pw [kW]=

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 69 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 38 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 894 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C Casing diameter d.i.L. = 894 mm
Outlet cross section A2 = 0.63 m2

c = Flow velocity (m/s) Density = 1.2 kg/m3 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.63 m2

rpm rpm

Total pressure increase ⌬ pt (Pa)


Total pressure increase ⌬ pt (Pa)

Blade
pitch Blade
angle pitch
angle

with duct with duct


2.5 D 2.5 D
=

5° 15°
15°
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

5° 20° 20° 25°


␩· 1000 · 3600

␩· 1000 · 3600

10°
10° 25° 30°
Total acoustic power

Total acoustic power

30°
Shaft power input
Shaft power input

35°
35°
requirement
requirement

level Lw (dB)

level Lw (dB)
Pw [kW]=

Pw [kW]=

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 105
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 51 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 76 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1003 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. =1003 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.79 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.79 m2

rpm rpm
Don’t design
in the raster
area


Total pressure increase ⌬ pt (Pa)


Total pressure increase ⌬ pt (Pa)

Blade
Blade pitch
pitch angle angle

with duct with duct


2.5 D 2.5 D
=
=

5° 15° 5° 15°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]

␩· 1000 · 3600
␩· 1000 · 3600

20° 25° 10° 20°


10° 25°

Total acoustic power


Total acoustic power

30° 30°
Shaft power input
Shaft power input

35°
requirement

35°
requirement

level Lw (dB)
level Lw (dB)

Pw [kW]=
Pw [kW]=

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 43 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 57 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1124 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1124 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.0 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.0 m2

rpm rpm


Total pressure increase ⌬ pt (Pa)

Total pressure increase ⌬ pt (Pa)

BVAXN 8/56

Blade Blade
pitch pitch
angle angle

with duct with duct


2.5 D 2.5 D

5° 15° 5° 15°
=

20°
10° 25° 20°
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

25°
␩· 1000 · 3600

␩· 1000 · 3600

30° 10° 30°


Total acoustic power
Total acoustic power
Shaft power input

Shaft power input

35° 35°
requirement

requirement

level Lw (dB)
level Lw (dB)
Pw [kW]=

Pw [kW]=

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 106
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 48 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 65 m/s 65 Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1261 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1261 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.25 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.25 m2
1,25

rpm rpm


Total pressure increase ⌬ pt (Pa)

Total pressure increase ⌬ pt (Pa)


Blade
pitch Blade
angle pitch angle

with duct with duct


2.5 D 2.5 D

5° 15° 5°
=

20° 15°
10°
V̇[m3/h] · ⌬pt [Pa]

V̇[m3/h] · ⌬pt [Pa]

25°
␩· 1000 · 3600

20°
␩· 1000 · 3600

30° 10° 25°


30°
Total acoustic power

Total acoustic power


35°
Shaft power input

Shaft power input

35°
requirement

requirement
level Lw (dB)

level Lw (dB)
Pw [kW]=

Pw [kW]=

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 54 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 72 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1415 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C Casing diameter d.i.L. = 1415 mm
Outlet cross section A2 = 0.57 m2 c = Flow velocity (m/s)
␦ Outlet cross section A2 = 1.57 m2
c = Flow velocity (m/s) Density = 1.2 kg/m3 Density = 1.2 kg/m3

rpm rpm
Don’t design in
the raster area


Total pressure increase ⌬ pt (Pa)

Total pressure increase ⌬ pt (Pa)

Blade
pitch Blade
angle pitch angle

with duct with duct


2.5 D 2.5 D

5° 15°
=

5° 15°
V̇[m3/h] · ⌬pt [Pa]

20°
V̇[m3/h] · ⌬pt [Pa]

10° 20°
␩· 1000 · 3600

25°
␩· 1000 · 3600

25° 10°
30° 30°
Total acoustic power

Total acoustic power


Shaft power input

Shaft power input

35° 35°
requirement

requirement
level Lw (dB)

level Lw (dB)
Pw [kW]=

Pw [kW]=

* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 107
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 62 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1587 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.98 m2

rpm
➞Total pressure increase ⌬ pt (Pa)

Blade
pitch
angle

with duct
2.5 D
=

5° 15°
V̇[m3/h] · ⌬pt [Pa]

20°
␩· 1000 · 3600

10° 25°
30°
Total acoustic power
Shaft power input

35°
requirement

level Lw (dB)
Pw [kW]=

Necessary cooling air V [m3/h] for BVAXN 8/56 series (600°C – 120 min.)

Nominal fan speed (rpm) Type of Motor output Current Flange for
cooling 400 V/50 Hz consumption duct-
750 1000 1500 3000 air fan at 2,800 rpm [A] connection
[kW] [mm]
Size V ⌬pk ⌬pex V ⌬pk ⌬pex V ⌬pk ⌬pex V ⌬pk ⌬pex

500 120 100 430 160 180 300 240 400 50 240 400 50 4-14 0,18 0,52 100x100
BVAXN 8/56

630 120 100 430 160 180 300 240 400 50 4-14 0,18 0,52 100x100

710 120 100 430 160 180 300 240 400 50 4-14 0,18 0,52 100x100

800 265 110 390 355 195 305 530 440 80 5-19 0,25 0,86 200x100

900 265 110 390 355 195 305 530 440 80 5-19 0,25 0,86 200x100

1000 375 140 510 500 250 400 750 565 135 6-35 0,75 1,75 250x100

1120 375 140 510 500 250 400 6-35 0,75 1,75 250-100

1250 375 140 510 500 250 400 6-35 0,75 1,75 250x100

1400 1200 280 820 1800 630 370 8-70 2,2 4,6 315x140

1600 1800 630 820 8-70 2,2 4,6 315x140

⌬pk = internal pressure loss of fan-owned cooling air system [Pa]


⌬pex = additionally available pressure from cooling air duct losses [Pa]
V = Qty. of cooling air [m3/h] at 40° cooling air temperature
* rounded to standard values For maximum motor sizes please see dimension pages
– 108 –
Unit price Total
Item
Qty. Description
No.
2 2

Axial Smoke Exhaust Fan, BVAXN 8/56, type M-D


for the extraction of smoke fumes of
max. 600°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-17
Airflow direction: outlet over motor,
direct drive.
For installation of axial smoke exhaust fans outside the fire
compartment:
• Wiring to the casing-mounted special terminal box and cooling
fan terminal box to be provided by customer
• Motor cooling via directly flange-mounted cooling fan

For installation of axial smoke exhaust fans inside the fire


compartment:
Wiring to be provided by customer, as above, using heat-resi-
stant cables. Terminal box heat insulation to be customer-sup-
plied.
or Motor cable (2 m) extending out of the motor cooling air port for
routing through customer-supplied cooling air duct. (Longer ca-
ble available against surcharge).
Terminal box loosely supplied.
or Motor cooling by a separate cooling air fan to be fitted outside
the fire compartment (via customer-supplied insulated cooling
air duct).
consisting of:
Duct casing of welded sheet steel construction, with drilled flan-
ges according to DIN 24154, Series 3
Guide vanes for pressure boosting and to ensure an essentially
swirl-free outlet flow.
Motor enclosed and insulated, arranged in the inner casing.
Standard surface finish:
• 2-component polyacrylate coating, colour: RAL 7030
Sheet steel impeller with fixed (non-adjustable) blades, dynami-
cally balanced, ISO 1940, Quality Grade G 6,3
mounted on motor output shaft.
Outlet side configurations:
Duct connection
or Free outlet without diffuser
or Free outlet with diffuser

Carryover
– 109 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Specifications – BVAXN 8/56


Volume flow m3/h
Temperature (design) 20°C
Temperature (max./withstand time) 600°C/120 min
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Efficiency %
Power requirement kW
Three-phase motor
single-speed
or with Dahlander pole-changing winding
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz
Protection class (IP)
Style B 14 / V18
Size
Total acoustic power level LW dB

Air cooling fan type:


Air cooling fan specifications:
Cooling air volume flow m3/h
Additionally available pressure for
customer supplied cooling duct
(if mounted in fire compartment) Pa
Motor output kW
Motor speed rpm
Nominal motor current A
Voltage V
Frequency Hz
Weight (fan with accessories) approx. kg

Manufacturer: TLT-Turbo GmbH BVAXN 8/56

Type: BVAXN 8/56/..... MD

Carryover
– 110 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment
• Cooling air fan (standard version)
• Set of mounting feet
• Flexible connector, heat resistant *
- inlet side
- outlet side
• Set of matching flanges *
• Bellmouth incl. flange
• Wire guard
• Set of spring-type AV mounts *
• Brackets for vertical installation
• Diffuser with interior core *
• Wire guard (diffuser-outlet)
• Galvanized fan
• Outlet duct with wire guard *
• Outlet duct with self-activating damper and wire guard *
• Duct with self-activating damper *
In case of installation of BVAXN inside the fire zone
• Flexible connector für connection to cooling air duct
• Longer motor-cable, length ….. m
• Cooling air fan (special version)
• Weather guard for cooling air fan

Note: Please observe our Installation, Operating


and Maintenance Instructions
(available upon request).

* Loosely supplied
TWO-STAGE AXIAL SMOKE EXHAUST FANS
BVZAXN 12/56 SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300/400°C – 120 MIN 113
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

i.d.

Further technical details may be taken from our special Important! This fan series is available only with the motor
catalogue « Multi-Storey Fans for Ventilation and outputs stated in our price lists.
Smoke Extraction ». Please ask for your copy.

up to up to upto
Weight 2) L1* Weight 2) L2* Weight
2)
a1 b1
Size i.d. Øk ØD z x d1) motor L motor y motor H a c b x
[kg] [kg] [kg]
size size size
BVZAXN 12/56
355 359 395 425 8 x 9,5 80 660 25 90 825 8 30 90 990 35 270 356 330 35 330 270 77
400 401 438 468 12 x 9,5 90 752 36 112 940 54 43 112 1128 51 300 406 379 37 370 300 88
450 450 487 517 12 x 9,5 90 800 43 112 1000 34 52 112 1200 62 335 430 400 37 410 330 88
500 504 541 571 12 x 9,5 112 900 56 132 1125 81 68 132 1350 80 375 480 453 37 460 380 100
560 565 605 643 16 x 11,5 112 968 82 132 1210 64 99 132 1452 117 420 519 483 45 510 430 100
630 634 674 712 16 x 11,5 132 1144 105 –– –– –– –– –– -– –– 470 607 575 45 550 470 128
710 711 751 789 16 x 11,5 132 1220 130 160 1525 112 152 160 1830 174 525 645 613 45 620 530 128
800 797 837 875 24 x 11,5 132 1400 164 180 1750 104 198 180 2100 232 585 735 703 45 730 640 150
900 894 934 972 24 x 11,5 132 1492 220 225 1865 78 264 225 2238 309 655 781 753 45 730 640 149
1000 1003 1043 1081 24 x 11,5 160 1660 274 225 2075 113 329 225 2490 383 730 881 833 57 830 740 165
1120 1126 1174 1214 24 x 11,5 180 1800 380 250 2250 180 450 280 2700 495 760 951 903 57 920 820 170
1250 1263 1311 1351 24 x 11,5 200 2000 450 250 2500 115 570 280 3000 625 855 1051 1003 57 1030 930 185
1400 1415 1465 1545 24 x 11,5 180 2000 please ask – – – please ask 315 2900 please ask 930 – – – – – –
1600 1587 1637 1717 32 x 11,5 225 2200 please ask – – – please ask 315 2900 please ask 1020 – – – – – –
Dimensions in mm
1) connecting dim. in acc. with DIN 24154 series 3 2) without motors. * Here further ducts are required, dim. a + a1 are therefore different

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
TWO-STAGE AXIAL SMOKE EXHAUST FANS
BVZAXN 12/56 SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300/400°C – 120 MIN 114
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Wire Bellmouth inlet Flexible Angular Matching Spring-type


guard with flange connector wall ring flange AV mounts

V103
ca. 60 V105
V108

i.d.1
i.d.1

i.d.1
i.d.1

ca. 80 V112
V120
V130
V150

200 Installation
length For diffusors please see page 063

Duct Outlet cone


with self-activating damper with wire guard

C G L4 L2
Øk

Wire guard
zxd L3

Size i.d.1 Øk ØD z x d1 Ø D1 C e f L2 L3 L4 C G

355 361 395 425 8 x 9,5 501 69 80 50 280 80 165 250 40


400 403 438 468 12 x 9,5 562 78 80 50 280 60 188 280 40
450 452 487 517 12 x 9,5 631 87 80 50 290 70 200 350 200
500 506 541 571 12 x 9,5 708 98 80 50 280 60 225 390 200
560 568 605 643 16 x 11,5 794 109 100 70 330 70 242 430 200
630 637 674 712 16 x 11,5 875 95 100 70 330 70 286 465 200
710 714 751 789 16 x 11,5 972 103 100 70 350 70 305 505 200
800 800 837 875 24 x 11,5 1081 115 100 70 520 200 350 550 200
900 897 934 972 24 x 11,5 1214 130 100 70 585 225 373 620 200
1000 1006 1043 1081 24 x 11,5 1351 145 100 70 640 240 415 690 200
1120 1133 1174 1214 24 x 11,5 1470 160 110 90 730 250 450 790 270
1250 1270 1311 1351 24 x 11,5 1677 185 110 90 810 250 500 900 270
1400 1424 1465 1505 24 x 11,5 1870 210 130 100
please ask
1600 1587 1637 1677 32 x 11,5 2087 210 130 100
1) connecting dim. in acc. with DIN 24154 series 3
Dimensions in mm
TWO-STAGE AXIAL SMOKE EXHAUST FANS
BVZAXN 12/56 SERIES
VERTICAL INSTALLATION SIZE 355 TO 1250
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany MOUNTING BRACKETS, TERMINAL BOX, INSPECTION HATCH 115
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

airflow upward airflow downward


Sizes 355 - 1250 Sizes 355 - 1250
G I J L

4 casings = 4 mounting brackets 4 casings = 4 mounting brackets


H Sizes 355 to 630 K Sizes 355 to 630
5 to 6 casings = 4 mounting brackets 5 to 6 casings = 8 mounting brackets

Sizes 710 to 1250 Sizes 710 to 1250


5 to 6 casings = 8 mounting 5 to 6 casings = 8 mounting
brackets brackets

Inspection Inspection
hatch hatch

Inspection Inspection
hatch hatch
Terminal box Terminal box

Airflow upward* (with outlet diffuser)

Sizes 500 to 630 Sizes 710 to 1250


5 casings = 4 mounting brackets 5 casings = 8 mounting brackets
P
Sizes 500 to 630 N
Sizes 710 to 1250
4 casings = 4 mounting brackets 4 casings = 8 mounting brackets BVZAXN 12/56
Diffuser with
M shortened O
intererior core Diffuser
with
shortened
intererior
core

*Please ask for airflow downward


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
TYP BZAXN 12/56 300°C - 120 Min
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany TECHNICAL LISTS (AVAILABLE MODELS) 116
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

355 3000 1,5 3,25 90 B14 160 630 1000 0,75 2,2 90 B5 200
2,2 4,6 90 B14 160 1,1 3,15 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B14 160 1500 1,5 3,5 90 B5 200
3000/1500 1,5/0,37 3,7/1,0 90 B14 160 2,2 5,5 100 B5 250
3,0 7,1 100 B5 250
400 1500 1,1 2,80 90 B5 200 4,0 8,6 112 B5 250
3000 1,5 3,25 90 B5 200 1000/500 0,8/0,15 2,3/0,9 90 B5 200
2,2 4,6 90 B5 200 1,2/0,22 3,1/1,15 100 B5 250
3,0 6,7 100 B14 200 1500/750 2,5/0,6 5,6/2,2 100 B5 250
4,0 8,3 112 B14 200 3,8/1,0 8,1/3,4 112 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B5 200 5,5/1,4 11,4/4,3 132 B5 250
3,0/0,75 6,7/1,7 100 B14 200
4,1/1,0 8,8/2,1 112 B14 200 710 1000 1,1 3,15 90 B5 200
1,5 3,9 100 B5 250
450 1500 1,1 2,8 90 B5 200 2,2 5,4 112 B5 250
3000 3,0 6,7 100 B14 200 1500 3,0 7,1 100 B5 250
4,0 8,3 112 B14 200 4,0 8,6 112 B5 250
5,5 11 112 B14 200 5,5 11,4 132 B5 250
1500/750 1,0/0,25 2,4/1,0 90 B5 200 7,5 15,4 132 B5 250
3000/1500 3,0/0,75 6,7/1,7 100 B14 200 1000/500 1,2/0,22 3,1/1,15 100 B5 250
4,1/1,0 8,8/2,1 112 B14 200 1,85/0,33 4,6/1,6 112 B5 250
3,3/0,75 9,3/3,6 132 B5 250
500 1500 1,1 2,8 90 B5 200 1500/750 5,5/1,4 11,4/4,3 132 B5 250
1,5 3,5 90 B5 200 7,0/1,7 15,2/5,1 132 B5 250
3000 4,0 8,3 112 B5 250 11/3,0 24/9,5 160 B5 350
5,5 11 132 B5 250
7,5 14,6 132 B5 250 800 1000 2,2 5,4 112 B5 250
11 20,5 132 B5 250 3,0 7,4 132 B5 250
1000/500 0,48/0,08 1,6/0,58 90 B5 200 4,0 9,2 132 B5 250
1500/750 1,4/0,35 3,3/1,35 90 B5 200 1500 5,5 11,4 132 B5 250
3000/1500 3,0/0,75 6,7/1,7 100 B5 250 7,5 15,4 132 B5 250
6,0/1,5 13,3/3,2 132 B5 250 11 22 160 B5 350
7,8/2,0 16,2/4,1 132 B5 250 15 29,5 160 B5 350
1000/500 2,6/0,5 7,1/2,8 132 B5 250
560 100 0,75 2,2 90 B5 200 3,3/0,75 9,3/3,6 132 B5 250
1500 1,1 2,8 90 B5 200 4,4/1,0 11/4,4 132 B5 250
1,5 3,5 90 B5 200 1500/750 5,5/1,4 11,4/4,3 132 B5 250
1500 2,2 5,5 100 B5 250 7,0/1,7 15,2/5,1 132 B5 250
1000/500 0,8/0,15 2,3/0,9 90 B5 200 11/3,0 24/9,5 160 B5 350
1500/750 1,4/0,35 3,3/1,35 90 B5 200 14/3,5 30,5/11,4 160 B5 350
2,5/0,6 5,6/2,2 100 B5 250

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
TYP BZAXN 12/56 300°C - 120 Min
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany TECHNICAL LISTS (AVAILABLE MODELS) 117
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

900 1000 3,0 7,4 132 B5 250 1120 750 4,0 9,3 160 B5 350
4,0 9,2 132 B5 250 5,5 11,4 160 B5 350
5,5 12,7 132 B5 250 7,5 16,1 160 B5 350
7,5 15,7 160 B5 350 11 23,5 180 B5 350
1500 11 22 160 B5 350 1000 7,5 15,7 160 B5 350
15 29,5 160 B5 350 11 22 160 B5 350
18,5 36 180 B5 350 15 29,5 180 B5 350
22 43 180 B5 350 20 40 200 B5 400
30 52 200 B5 350 22 43 200 B5 400
1000/500 3,3/0,75 9,3/3,6 132 B5 250 30 57 225 B5 450
4,4/1,0 11/4,4 132 B5 250 1500 30 52 200 B5 400
6,3/1,5 15,7/5,4 160 B5 350 37 66 225 B5 450
8,8/2,2 20,5/7,0 160 B5 350 45 82 225 B5 450
1500/750 11/3,0 24/9,5 160 B5 350 55 (L) 97 250 B5 550
14/3,5 30,5/11,4 160 B5 350 75 (L) 132 280 B5 550
16/4,0 32,5/11,9 180 B5 350 1000/500 6,3/1,5 15,7/5,4 160 B5 350
20/5,5 39/16,2 180 B5 350 7,5/1,85 19/6,7 160 B5 350
28/7,0 52/16,2 200 B5 350 8,8/2,2 20,5/7,0 160 B5 350
1500/1000 12/3,5 24/9,5 160 B5 350 12,5/3,0 32,5/11 180 B5 350
15,5/3,3 34/11 200 B5 400
1000 1000 5,5 12,7 132 B5 250 18,5/4,4 40/13,3 200 B5 400
7,5 15,7 160 B5 350 22/5,5 41/13,3 225 B5 450
11 22 160 B5 350 27/6,6 51/18 225 B5 450
15 29,5 180 B5 350 1500/750 28/7,0 52/16,2 200 B5 400
1500 15 29,5 160 B5 350 33/8,0 60/19 225 B5 450
18,5 36 180 B5 350 37/9,2 69/24,5 225 B5 450
22 43 180 B5 350 39/9,5 (L) 72/21 225 B5 450
30 52 200 B5 350 44/11 (L) 78/24 225 B5 450
37 66 225 B5 450 49/12 (L) 84/23 250 B5 550 BVZAXN 12/56
45 82 225 B5 450 1500/750 68/17 (L) 125/43,5 280 B5 550
1000/500 4,4/1,0 11/4,4 132 B5 250 80/20 (L) 140/48 280 B5 550
6,3/1,5 15,7/5,4 160 B5 350
8,8/2,2 20,5/7,0 160 B5 350 1250 750 5,5 11,4 160 B5 350
12,5/3,0 32,5/11 180 B5 350 7,5 16,1 160 B5 350
1500/750 16/4,0 32,5/11,9 180 B5 350 11 23,5 180 B5 350
20/5,5 39/16,2 180 B5 350 15 31 200 B5 400
28/7,0 52/16,2 200 B5 350 18,5 37 225 B5 450
32/8,0 60/19 225 B5 450 1000 11 22 160 B5 350
37/10 69/24,5 225 B5 450 15 29,5 180 B5 350
20 40 200 B5 400
22 43 200 B5 400
30 57 225 B5 450
37 67 225 B5 450
45 (L) 81 280 B5 550
 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
TYP BZAXN 12/56 300°C - 120 Min
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany TECHNICAL LISTS (AVAILABLE MODELS) 118
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Fan Motor 400 V, 50 Hz Fan Motor 400 V, 50 Hz


Nominal Output Nominal Flange Nominal Output Nominal Flange
Size Size Type Size Size Type
speed [kW] current [A] dia. speed [kW] current [A] dia.
[rpm]  [rpm] 

1250 1500 45 82 225 B5 450 1600 750 22 44,5 225 B5 450


55 (L) 97 250 B5 550 30 (L) 60 250 B5 550
75 (L) 132 280 B5 550 37 (L) 73 280 B5 550
90 (L) 157 280 B5 550 45 (L) 88 280 B5 550
110 (L) 200 315 55 (L) 110 315 B5 660
132 (L) 240 315 75 (L) 145 315 B5 660
1000/500 12,5/3,0 32,5/11 180 B5 350 1000 45 (L) 81 280 B5 550
15,5/3,0 34/11 200 B5 400 55 (L) 99 280 B5 550
18,5/4,4 40/13,3 200 B5 400 75 (L) 136 315 B5 660
22/5,5 41/13,3 225 B5 450 90 (L) 160 315 B5 660
27/6,6 51/18 225 B5 450 110 (L) 195 315 B5 660
30/7,0 (L) 58/19 250 B5 550 132 (L) 228 315 B5 660
1500/750 44/11 (L) 78/24 225 B5 450 1000/500 40/8,0 (L) 74/24 280 B5 550
49/12 (L) 84/23 250 B5 550 48/9,5 (L) 88/28 280 B5 550
68/17 (L) 125/43,5 280 B5 550 58/12 (L) 106/22 315 B5 660
80/20 (L) 140/48 280 B5 550 70/14 (L) 125/33 315 B5 660
82/16 (L) 150/37 315 B5 660
1400 750 11 23,5 180 B5 350 103/20 (L) 185/47 315 B5 660
15 31 200 B5 400 750 22 44,5 225 B5 450
18,5 37 225 B5 450 30 (L) 60 250 B5 550
22 44,5 225 B5 450 37 (L) 73 280 B5 550
30 60 250 B5 550 45 (L) 88 280 B5 550
45 88 280 B5 550 55 (L) 110 315 B5 660
1000 22 43 200 B5 400 75 (L) 145 315 B5 660
30 57 225 B5 450 1000 45 (L) 81 280 B5 550
37 74 225 B5 450 55 (L) 99 280 B5 550
45 (L) 81 280 B5 550 75 (L) 136 315 B5 660
55 (L) 99 280 B5 550 90 (L) 160 315 B5 660
75 (L) 136 315 B5 660 110 (L) 195 315 B5 660
1000/500 18,5/4,4 32,5/11 200 B5 400 132 (L) 228 315 B5 660
22/5,0 41/13,3 225 B5 450 1000/500 48/9,5 (L) 88/28 280 B5 550
27/6,0 51/18 225 B5 450 58/12 (L) 106/22 315 B5 660
30/7,0 (L) 58/19 250 B5 550 70/14 (L) 125/33 315 B5 660
40/8,0 (L) 74/24 280 B5 550 82/16 (L) 150/37 315 B5 660
48/9,5 (L) 88/28 280 B5 550 103/20 (L) 185/47 315 B5 660
58/12 (L) 106/22 315 B5 660
70/14 (L) 125/33 315 B5 660
82/16 (L) 150/37 315 B5 660

 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C - 120 MIN 119
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVZAXN 12/56

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 120
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 121
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVZAXN 12/56

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 122
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 123
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVZAXN 12/56

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 124
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 125
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVZAXN 12/56

* Also available for 200 or 400°C - 120 min.


TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C – 120 MIN 126
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
– 127 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Axial Smoke Exhaust Fan BVZAXN 12/56 TYPE M – D


for the extraction of smoke fumes
of max. 200°C – 120 min. approval no. Z-78.1-18
or of max. 300°C – 120 min. approval no. Z-78.1-20
or of max. 400°C – 120 min. approval no. Z-78.1-21
tested in accordance with EN 12101-T3 (Munich Technical
University)
Airflow direction: motor in outlet
Direct-drive type (2 fans connected in series)
Appropriate for installation in- and outside of fire-zone.
For ventilation of multi-storey car parks and for increase of
pressure
Consisting of:
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box
Surface protection:
• Polyester powder coating; colour: RAL 7030
• as of nominal size 1120: with full paint finish, Colour: RAL 7030
Aluminium impeller, blade pitch fully adjustable when at rest,
directly mounted on motor shaft end. (Blade pitch at 400°C
version not adjustable)
Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Technical data:
Volume flow m3/h
Temperature/air humidity C/%RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level Lw dB BVZAXN 12/56
Efficiency %
Power input requirement 2 x kW
Three-phase motor:
• single-speed
• Dahlander pole-changing type
• pole-changing type with separate windings
Motor speed rpm
Motor output 2 x kW
Current consumption 2 x A
Voltage Volt
Frequency Hz
Protection class (IP)
Type B/V
Size
Weight: fan with accessories approx. kg
Manufacturer: TLT-Turbo GmbH

Type: BVZAXN 12/56/..........M-D Carryover


– 128 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment:

• Galvanised fan
• Fan with special coating
• Extension casing without inspection hatch
• Inspection hatch
• Bellmouth inlet with flange
• Wire guard on bellmouth side
• Wire guard on extension casing (motor side)
• Flexible connector, inlet side*
• Flexible connector, outlet side*
• Matching flange inlet side*
• Matching flange outlet side*
• Angular wall ring with brackets*
• Set of mounting feet (2 pcs.)*
• Set of spring-type antivibration mounts*
• Brackets for vertical fan installation
• Diffuser with interior core*
• Flexible connector (diffuser outlet)*
• Wire guard (diffuser outlet)*
• Round silencer, TSR type*
• Outlet cone with wire guard
• Duct with self-activating damper

Note: Please see our Installation, Operating and


Maintenance Instructions that are available on
request

* Loosely supplied

Carryover
WALL-MOUNTING AXIAL SMOKE EXHAUST FANS
BWAXO SERIES
200 / 300 °C – 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN. 130
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

View „A“

Direction of flow

Wall opening

Pressure loss across shutoff damper (overpressure louvre)

View "B"
(shown without louvre-type damper)

Flow velocity*c
Pressure losses of fan and shutoff damper sum up to the total
pressure increase needed for the sizing of complete fan units
Please refer to the characteristic (assuming free inlet / free outlet conditions).
curves on pages 053-055.
*For flow velocities please refer to the characteristic curves.

Weight
Size approx. [kg]
(without
motor)

330 25
40
900 65
450 90
Dimensions in mm
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
– 131 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Wall-mounting Axial Smoke Exhaust Fan, BWAXO Series


Type M-D
for the extraction of smoke fumes of
max. 200°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-41
Airflow direction: outlet over motor, direct drive.
Consisting of:
Duct casing of welded sheet steel construction, with drilled
flanges according to DIN 24154 - Series 3, special motor
arranged in the exhaust gas flow, with temperature-resis-
tant terminal box fitted on the casing.
Surface protection:
• Polyester powder coating, colour: RAL 7030
Louvre damper slats: made of aluminium
Louvre damper frame and wire guard: galvanized.
• Impeller made of cast aluminium, directly mounted on mo-
tor shaft, non-adjustable blades
• Bellmouth with wire guard
• Wall-mounting plate (inside)
• Outlet box (outside)
• Louvre damper (outside)
Specifications:
Volume flow m3/h
Temperature (design) °C
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle °
Total sound power level LW dB
Efficiency %
Power requirement kW
Three-phase motor:
single-speed
or with Dahlander pole-changing winding
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz
Protection class IP
Style B
BWAXO

Size
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH

Type: BWAXO ..... MD


Accessory equipment needed in connection with use of in-
let duct
• Flexible connector (in this case please deduct price of
bellmouth and inlet wire guard from fan price)
Note: Please observe our Installation, Operating and Main-
tenance Instructions (available upon request).

Carryover
– 132 –
Unit price Total
Item
Qty. Description
No.
2 2

Wall-mounting Axial Smoke Exhaust Fan, BWAXO Series


Type M-D
for the extraction of smoke fumes of
max. 300°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-41
Airflow direction: outlet over motor, direct drive.
Consisting of:
Duct casing of welded sheet steel construction, with drilled
flanges according to DIN 24154 - Series 3, special motor
arranged in the exhaust gas flow, with temperature-resis-
tant terminal box fitted on the casing.
Surface protection:
• Polyester powder coating, colour: RAL 7030
Louvre damper slats: made of aluminium
Louvre damper frame and wire guard: galvanized.
• Impeller made of cast aluminium, directly mounted on mo-
tor shaft, non-adjustable blades
• Bellmouth with wire guard
• Wall-mounting plate (inside)
• Outlet box (outside)
• Louvre damper (outside)
Specifications:
Volume flow m3/h
Temperature (design) °C
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle °
Total sound power level LW dB
Efficiency %
Power requirement kW
Three-phase motor
single-speed
or with Dahlander pole-changing winding
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz
Protection class IP
Style B
Size
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH

Type: BWAXO ..... MD


Accessory equipment needed in connection with use of in-
let duct
• Flexible connector (in this case please deduct price of
bellmouth and inlet wire guard from fan price)

Note: Please observe our Installation, Operating and Main-


tenance Instructions (available upon request).
Carryover
WALL-MOUNTING AXIAL SMOKE EXHAUST FANS
BWAXN 12/56 SERIES
200 / 300 / 400 °C – 12
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C - 120 MIN. 133
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

View „A“

Direction of flow

Wall opening

Pressure loss across shutoff damper (overpressure louvre)

View "B"
(shown without louvre-type damper)

Flow velocity*c
Pressure losses of fan and shutoff damper sum up to the total pressure
increase needed for the sizing of complete fan units (assuming free
BWAXO

inlet / free outlet conditions).


Please refer to the characteristic
curves on pages 078-082. *For flow velocities please refer to the characteristic curves „free outlet“
installation (red curves and numbers)

Weight
Size approx. [kg]
(without
motor)

900

Dimensions in mm
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
– 134 –
Unit price Total
Item
Qty. Description
No.
2 2

Wall-mounting Axial Smoke Exhaust Fan BWAXN 12/56


Type M-D
for the extraction of smoke fumes of
max. 200°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-18
Airflow direction: outlet over motor, direct drive.
For wall installation inside or outside the fire zone.
Consisting of:
Duct casing of welded sheet steel construction, with drilled
flanges according to DIN 24154 - Series 3; guide vanes for
pressure boosting and to ensure an essentially swirl-free
outlet flow; special motor arranged in the exhaust gas flow,
with temperature-resistant terminal box fitted on the casing.
Surface protection:
• Polyester powder coating, colour: RAL 7030
Louvre damper slats: made of aluminium
Louvre damper frame and wire guard: galvanized.
• Impeller made of cast aluminium, blades steplessly
adjustable on the stationary fan, directly mounted on
motor shaft
• Bellmouth with wire guard
• Wall-mounting plate (inside)
• Outlet box (outside)
• Louvre damper (outside)
Specifications:
Volume flow m3/h
Temperature (design) °C
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle °
Total sound power level LW dB
Efficiency %
Power requirement kW
Three-phase motor
single-speed
or with Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz
Protection class IP
Style B
Size
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH

Type: BWAXN 12/56 .... MD


Accessory equipment needed in connection with use of in-
let duct
• Flexible connector (in this case please deduct price of
bellmouth and inlet wire guard from fan price)
Note: Please observe our Installation, Operating and Main-
tenance Instructions (available upon request).
Carryover
– 135 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Wall-mounting Axial Smoke Exhaust Fan BWAXN 12/56


Type M-D
for the extraction of smoke fumes of
max. 300°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-20
Airflow direction: outlet over motor, direct drive.
For wall installation inside or outside the fire zone.
Consisting of:
Duct casing of welded sheet steel construction, with drilled
flanges according to DIN 24154 - Series 3; guide vanes for
pressure boosting and to ensure an essentially swirl-free
outlet flow; special motor arranged in the exhaust gas flow,
with temperature-resistant terminal box fitted on the casing.
Surface protection:
• Polyester powder coating, colour: RAL 7030
Louvre damper slats: made of aluminium
Louvre damper frame and wire guard: galvanized.
• Impeller made of cast aluminium, blades steplessly
adjustable on the stationary fan, directly mounted on
motor shaft
• Bellmouth with wire guard
• Wall-mounting plate (inside)
• Outlet box (outside)
• Louvre damper (outside)
Specifications:
Volume flow m3/h
Temperature (design) °C
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle °
Total sound power level LW dB
Efficiency %
Power requirement kW
Three-phase motor
single-speed
or with Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW BWAXN 12/56
Nominal motor current A
Voltage V
Frequency Hz
Protection class IP
Style B
Size
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH

Type: BWAXN 12/56 .... MD


Accessory equipment needed in connection with use of in-
let duct
• Flexible connector (in this case please deduct price of
bellmouth and inlet wire guard from fan price)
Note: Please observe our Installation, Operating and Main-
tenance Instructions (available upon request).
Carryover
– 136 –
Unit price Total
Item
Qty. Description
No.
2 2

Wall-mounting Axial Smoke Exhaust Fan BWAXN 12/56


Type M-D
for the extraction of smoke fumes of
max. 400°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-21
Airflow direction: outlet over motor, direct drive.
For wall installation inside or outside the fire zone.
Consisting of:
Duct casing of welded sheet steel construction, with drilled
flanges according to DIN 24154 - Series 3; guide vanes for
pressure boosting and to ensure an essentially swirl-free
outlet flow; special motor arranged in the exhaust gas flow,
with temperature-resistant terminal box fitted on the casing.
Surface protection:
• Polyester powder coating, colour: RAL 7030
Louvre damper slats: made of aluminium
Louvre damper frame and wire guard: galvanized.
• Impeller made of cast aluminium, non-adjustable blades,
directly mounted on motor shaft
• Bellmouth with wire guard
• Wall-mounting plate (inside)
• Outlet box (outside)
• Louvre damper (outside)
Specifications:
Volume flow m3/h
Temperature (design) °C
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle °
Total sound power level LW dB
Efficiency %
Power requirement kW
Three-phase motor
single-speed
or with Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz
Protection class IP
Style B
Size
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH

Type: BWAXN 12/56 .... MD


Accessory equipment needed in connection with use of in-
let duct
• Flexible connector (in this case please deduct price of
bellmouth and inlet wire guard from fan price)
Note: Please observe our Installation, Operating and Main-
tenance Instructions (available upon request).
Carryover
CENTRIFUGAL SMOKE EXHAUST FANS
PRODUCT RANGE 
TECHNICAL DESCRIPTION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 137
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Characteristic curves as of page 151 Characteristic curves as of page 151

BVW-A series BVW-R series BVW-R/B series with inlet duct


Temperature/Time category acc. to Temperature/Time category acc. to
EN 12101 part 3: EN 12101 part 3:

Centrifugal smoke exhaust fans BVW series


F 600 600°C - 120 min. F 600 600°C - 120 min.
Appropriate for installation outside Appropriate for installation inside of
of fire-zone. Motor cooled with firze-zone. Motor-requires outside
abient air. air cooling.
Product range:
Product range: 6 sizes
6 sizes more than 35 types
more than 35 types Volume flow up to 48 000 m3/h
Volume flow up to 48 000 m3/h total pressure increase
total pressure increase up to appr. 2 000 Pa
up to appr. 2 000 Pa

Technical description Technical description


BVW-series BVW-A series
Direct-drive type, consisting of steel Direct-drive type, consisting of steel BVW-A/B series with duct
sheet housing, protected by an poly- sheet housing, protected by an poly- connector
ester powder coating, colour RAL ester powder coating, colour RAL
7030, with bellmouth, motor support 7030, with bellmouth, motor support
plate, companion flange as per DIN plate, companion flange as per DIN
24154, Series R3 companion frame 24154, Series R3 companion frame
as per DIN 24193, Series R2, smoke as per DIN 24193, Series R2.
inlet box (without motor enclousure). Centrifugal impeller, single inlet type,
Centrifugal impeller, single inlet type aerodynamically optimized, dynami-
aerodynamically optimized, dynami- cally balanced to DIN ISO 1940, qua-
cally balanced to DIN ISO 1940, qua- lity grade G 6,3 welded sheet steel
lity grade G 6,3 welded sheet steel with polyester powder coating,
with polyester powder coating, colour: RAL 7030.
colour: RAL 7030 Three-phase a.c. motor as per IEC
Three-phase a.c. motor as per IEC standard, style V 3/B 5; Protection
standard, style V 3 / B 5; Protection class IP 55, ISO class H
class IP 55, ISO class H Motor enclousure:
Round sheet steel housing, cooling
air suplied via cooling air inlet duct;
max. length of outside air supply li-
ne: 1,0 m. BVW-R/B series with free inlet

 for further types please see pages 142-147


WALL MOUNTING CENTRIFUGAL SMOKE EXHAUST FAN
BVW-A SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 138


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

D C B

A1
E

A
F

C D N

For dimensions please refer to page 148.

Max.
Size N weight
~kg
588
668
742
932
1182
1332
up to motor size 132
Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
WALL MOUNTING CENTRIFUGAL SMOKE 200°C – 120 min.
EXHAUST FAN 300°C – 60 min.
BVW-R SERIES 400°C – 120 min.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
without motor enclosure 139
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
600°C – 120 MIN and cooling air duct.

E Free inlet B

wA

v
H

a
øG b
C D N

For dimensions please refer to page 148.

Max.
BVW

Size N weight
~kg
588
668
742
932
425
800 680 1182
425
800 680 1332
up to motor size 132
Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
WALL MOUNTING CENTRIFUGAL SMOKE 200°C – 120 min.
EXHAUST FAN 300°C – 60 min.
BVW-R SERIES 400°C – 120 min.
without motor enclosure
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN and cooling air duct.
140
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

D C B

A1
A

V
H

a b
øG
C D N

Casing orientations*
For dimensions please
refer to page 148.

A B C

*Viewed from above

Max.
Size N weight
~kg
588
668
742
932
425
800 680 1182
425 1332
800 680
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
ROOF MOUNTING CENTRIFUGAL SMOKE EXHAUST FAN
BVW-D SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 141


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

øG

E1

H
A

C D B

For dimensions please refer to page 148.

Steel flat roof base with interior insulation


and double-shell design
B2

B3
e
M
350

B1 BVW

Max. Steel flat roof base


Weight
Size weight Stud bolts
~kg B1 B2  e B3 M ~kg
765 525 421 460 12x25 92
975 675 565 600 12x25 125
975 675 565 600 12x25 165
1265 965 850 880 16x25 230
425
800 680 1265 965 850 880 16x25 385
425
800 680 1425 1125 1000 1040 16x25 475
up to motor size 132
Dimensions in mm
motor sizes 160 and up

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
CENTRIFUGAL SMOKE EXHAUST FAN 200°C – 120 min.
BVW-R/B SERIES WITH INLET DUCT 300°C – 60 min.
MAIN DIMENSIONS 400°C – 120 min.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
without motor enclosure 142
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
600°C – 120 MIN and cooling air duct.

Floor mounting type


C
D C A1 A H
v

øG
B
B

D
h

M K
L1
2 For dimensions please refer to page 148.

Casing orientations * Casing orientation* Position of cooling


*
(inlet below) air ducts*

A C
H F D J K

Important!
Note special baseframe
dimensions (please ask).

I G E L B D
* View on motor enclosure.

Max.
Size weight
~kg

425
800 680
425
800 680
up to motor size 132 Dimensions in mm
motor sizes 160 and up

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
CENTRIFUGAL SMOKE EXHAUST FAN 200°C – 120 min.
BVW-R/B SERIES, FREE INLET 300°C – 60 min.
MAIN DIMENSIONS 400°C – 120 min.
without motor enclosure 143
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN and cooling air duct.
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Floor mounting type


C
D C
A H

øG
B
B

M K
L2
For dimensions please refer to page 148.

Casing orientations * Position of cooling air ducts *

A C

B D
D E F BVW

* View on motor enclosure.

Max.
Size ø 2
weight
~kg

425
800 680 1200
425
800 680 1250
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-A/B SERIES WITH INLET DUCT
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 144
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Floor mounting type

D C A1 A F

C
B

D
h

M K
L1

Casing orientations * Casing orientation* For dimensions


(inlet below) please refer to page 148.

H F D J K

Important!
Note special baseframe
dimensions (please ask).

I G E L
* View on motor enclosure.

Max.
Size 1 weight
~kg

950
1150
1550
1650
up to motor size 132 Dimensions in mm
motor sizes 160 and up

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-A/B SERIES WITH ROUND DUCT CONNECTION
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 145
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Floor mounting type


A F
D C

zxd

Øk
B

h
M K
L2

Casing orientations * For dimensions


please refer to page 148.

D E F

* View on motor enclosure.


BVW

Max.
Size Øk z x d weight
~kg
356 8x10
395 8x10
850 438 12x10
541 12x10
674 16x12
751 16x12
up to motor size 132 Dimensions in mm
motor sizes 160 and up

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-AI/B SERIES WITH INLET DUCT
AND ACOUSTIC AND THERMAL ISULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 146
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Floor mounting type indoors, outside the fire zone

100 A1 A F
D C
100

C
B

D
100
h

M K
L1

Casing orientations*
Casing orientations *  For dimensions
(inlet below)
please refer to
page 148

H F D J K

Important!
Note special baseframe
dimensions
(please ask).

I G E L
* View on motor enclosure.

Max.
Size 1 weight
~kg

950
1150
1550
1650
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-AI/B SERIES WITH ROUND DUCT CONNECTION
AND ACOUSTIC AND THERMAL ISULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 147
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Floor mounting type


indoors, outside the fire zone
100
D C
100

zxd A F

Øk
B

100
h
M K
L2

Casing orientations *  Abmessungen siehe Seite 148

D E F

* View on motor enclosure.


BVW

Max.
Size Øk z x d weight
~kg
356 8x10
395 8x10
850 438 12x10
541 12x10
674 16x12
751 16x12
up to motor size 132 Dimensions in mm
motor sizes 160 and up

For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FANS
BVW SERIES
Connecting Dimensions - All Types
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 148
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

s = 6 mm

Dimensions - Inlet / Outlet Side Frame


Size s

6
6
6
6
6
6

Dimensions - Frame for External Air Supply Connection


Size s

6
6
6
6
6
6

Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FAN
BVW SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 149
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Flexible connector Flexible connector Flexible connector (round)


(rectangular) for fan casing / for cooling air supply for BVW-A/B fans (page 145)
intake box with damper




Ø d2 i.d.


a/b
a/b

90 Installation length

90 Installation length L Installation length

BVW

Please fit flexible connectors with precisions, observing the installation length.

Dimensions
Size for  for  L (600°C) L (200 - 400°C) Ø d2 i.d.
a b a b
315 252 632 102 202 90 200 321
355 252 712 102 202 90 200 360
400 282 802 102 202 90 200 403
500 357 1002 142 317 90 200 506
630 452 1252 142 317 90 200 637
710 502 1402 142 317 90 200 714

 For connecting dimensions Please refer to page 148. Dimensions in mm


CENTRIFUGAL TYPE SMOKE EXHAUST FANS
BVW SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 150
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Wall transition sleeve Duct with shutoff damper


made of galvanized sheet steel and 2 flanges*

Cat. II or III Inlet wire guard


mortar according (rectangular)
to DIN 1053 A

Screw internally
during
Installation

M 8x16

* Also available for type BVW-A/B


Adjustable for and BVW-R/B
 120-210 wall thickness
 215-390 wall thickness

Spring-type antivibration Installation jigs


mounts
B(B1)

50

ca. 60
e(e1)
h(h1)

e(e1)

ca. 80
Dimensions in brackets apply to
installation on spring-type
antivibration mounts. Detailed
drawing showing installation jig
hole patterns available on request.

For installation with spring-type antivibration mounts.


Size A B h e B1 h1 e1 Ød

315 200 725 350 125 805 400 150 12


355 260 805 400 150 815 450 175 12
400 290 815 450 175 1095 500 200 12
500 370 1095 500 200 1345 600 225 14
630 470 1345 600 225 1490 600 225 14
710 530 1490 600 225 1490 600 225 14

Dimensions in mm
CENTRIFUGAL TYPE SMOKE EXHAUST FANS
BVW-A · BVW-R · BVW-D SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


600 °C – 120 MIN 151
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVW 315/30 Model Speed Motor Nominal


Max. weight approx

Flange dia
3000 rpm

Motor size
output current at
BVW-A
1800 400 V-50 Hz
Pressure losses BVW-R
BVW-D rpm kW approx A BVW-A
BVW-R BVW-R
––– Inlet box BVW-D **
- - - BVW-D damper
1600 ....... BVW-A or 315/30-6 910 0,55 1,6 80 200
R damper 315/30-4 1390 0,55 1,4 80 200
315/30-2 2880 4,4 9,5 112 250 112 92 114
315/30-2/4 2890/1440 4,1/1,0 8,8/2,1 112 250
1400 315/30-4/8 1400/670 0,7/0,18 2,0/0,8 80 200

= 1,2 kg/m3
315/30-4/6/8 1430/950/700 1,0/0,33/0,26 2,4/1,05/0,95 100 250
t = 20°C

1200

-2 * for motor size 112


** BVW-R with inlet duct
1000

800

Acoustic levels on outlet side (free-field conditions)


Additionally available pressure ⌬pt Pa 씮

600
Speed Relative acoustic power level
Acoustic level Vmax.
1500 rpm Octave center frequency Hz
400 [rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
670 74 65 45 68 71 64 63 60 56 51 46
-4
920 80 72 52 73 77 70 68 67 65 61 56
1000 rpm
200 1390 87 82 62 80 79 84 76 75 76 72 68
2880 101 98 78 93 92 90 96 89 90 92 88
-6
LpA: Average sound pressure level at 4 m distance (free field)
Measuring surface S = 101 (m2)
1000 2000 3000 4000 5000 6000 7000 8000 9000
Measuring surface level: Ls = 20 (dB)
Volume flow V m3/h 씮

Max. weight approx


BVW 355/30 Model Speed Motor Nominal
Flange dia
Motor size

output current at
1500 rpm BVW-A
600 400 V-50 Hz
BVW-R
Pressure losses
BVW-D rpm kW approx A BVW-R BVW-R
––– Inlet box BVW-A
BVW-D **
550 - - - BVW-D damper
....... BVW-A or 355/30-6 910 0,55 1,6 80 200
-4 R damper 355/30-4 1410 1,5 3,6 90 200
500
355/30-4/8 1400/680 1,4/0,35 3,3/1,35 90 200
355/30-4/6 1410/950 1,1/0,37 2,8/1,35 90 200
450 355/30-4/6/8 1430/950/700 1,0/0,33/0,26 2,4/1,05/0,95 100 250 136 125 136

= 1,2 kg/m3
t = 20°C
400

* for motor size 90


BVW

350 ** BVW-R with inlet duct

300

250 1000 rpm

Acoustic levels on outlet side (free-field conditions)


Additionally available pressure ⌬pt Pa 씮

200
-6 Speed Relative acoustic power level
Acoustic level Vmax.
Octave center frequency Hz
150
750 rpm [rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
420 66 58 38 63 60 60 56 52 47 42 37
100
-8 670 77 69 49 71 74 67 66 64 61 56 51
910 83 76 56 76 80 73 71 71 69 65 60
50 1410 91 86 66 84 82 87 80 79 80 77 72

LpA: Average sound pressure level at 4 m distance (free field)


1000 2000 3000 4000 5000 6000 Measuring surface S = 101 (m2)
Volume flow V m3/h 씮 Measuring surface level: Ls = 20 (dB)
CENTRIFUGAL TYPE SMOKE EXHAUST FANS
BVW-A · BVW-R · BVW-D SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


600 °C – 120 MIN 152
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVW 400/30 Model Speed Motor Nominal


Max. weight approx

Flange dia
1500 rpm

Motor size
750 output current at
BVW-A
400 V-50 Hz
Pressure losses BVW-R
kW approx A BVW-R BVW-R
700 BVW-D rpm BVW-A
––– Inlet box BVW-D **
- - - BVW-D damper
650 ....... BVW-A or 400/30-6 910 0,55 1,6 80 200
R damper 400/30-4 1410 1,5 3,6 90 200
400/30-4/8 1400/680 1,4/0,35 3,3/1,35 90 200
600
400/30-4/6 1405/930 1,6/0,6 3,9/1,8 100 250
400/30-4/6/8 1440/965/700 1,5/0,6/0,37 3,5/1,8/1,45 100 250 170 165 202
550 ␦
= 1,2 kg/m3
t = 20°C
500

450
* for motor size 100
** BVW-R with inlet duct
400
-4
350

1000 rpm
300

Acoustic levels on outlet side (free-field conditions)


Additionally available pressure ⌬pt Pa 씮

250
Speed Relative acoustic power level
Acoustic level Vmax.
200 Octave center frequency Hz
750 rpm -6 Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
[rpm]
150
-8 420 72 61 41 70 63 63 59 56 52 47 42
670 80 72 52 74 77 70 69 67 65 60 55
100
910 86 79 59 79 83 76 74 74 73 69 64
1400 94 89 69 87 85 90 82 81 83 81 77
50

LpA: Average sound pressure level at 4 m distance (free field)


Measuring surface S = 101 (m2)
1000 2000 3000 4000 5000 6000 7000 8000 9000
Volume flow V m3/h 씮
Measuring surface level: Ls = 20 (dB)

BVW 500/30 Model Speed Motor Nominal


Max. weight approx
Flange dia
Motor size

1500 rpm
output current at
1200 BVW-A
Pressure losses 400 V-50 Hz
BVW-R
––– Inlet box BVW-D rpm kW approx A BVW-A
BVW-R BVW-R
BVW-D **
1100 - - - BVW-D damper
....... BVW-A or 500/30-6 910 1,5 4,3 100 250
R damper 500/30-4 1420 5,5 11,5 132 250
1000 500/30-4/8 1420/700 5,5/1,4 11,4/4,3 132 250
500/30-4/6 1460/955 6,0/2,0 12,5/5,4 132 250 270 230 282
␦ 500/30-6/8/12 965/720/470 1,6/0,8/0,33 4,7/2,9/1,9 132 250
900 = 1,2 kg/m3
t = 20°C

800
-4
* for motor size 132
700 ** BVW-R with inlet duct

600

1000 rpm
500

Acoustic levels on outlet side (free-field conditions)


Additionally available pressure ⌬pt Pa 씮

400
Speed Relative acoustic power level
-6 Acoustic level Vmax.
750 rpm Octave center frequency Hz
300
[rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
-8
420 75 69 49 71 68 69 67 64 60 55 50
200
690 87 80 60 80 84 76 76 75 74 69 65
910 92 86 66 85 89 82 80 80 81 77 73
100 1420 100 96 76 93 91 96 88 87 90 89 85

LpA: Average sound pressure level at 4 m distance (free field)


Measuring surface S = 101 (m2)
2000 4000 6000 8000 10000 12000 14000 16000 18000
Measuring surface level: Ls = 20 (dB)
Volume flow V m /h 씮
3
CENTRIFUGAL TYPE SMOKE EXHAUST FANS
BVW-A · BVW-R · BVW-D SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


600 °C – 120 MIN 153
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVW 630/25 Model Speed Motor Nominal


Max. weight approx

Flange dia
Motor size
output current at
BVW-A
2000 400 V-50 Hz
Pressure losses BVW-R
kW approx A BVW-R BVW-R
––– Inlet box BVW-D rpm BVW-A
BVW-D **
- - - BVW-D damper
1800 ....... BVW-A or 630/25-6 940 3,0 7,0 132 300
1500 rpm R damper 630/25-4 1470 11 22 160 300
630/25-4/8 1460/710 10/3,0 22/10 160 300 460 385 474
1600
630/25-6/12 975/480 3,3/0,75 9,3/3,6 132 300
630/25-6/8/12 970/735/475 3,0/1,5/0,6 7,6/4,6/2,8 132 300

= 1,2 kg/m3
1400 t = 20°C

* for motor size 160


1200
** BVW-R with inlet duct

1000
-4

800
1000 rpm Acoustic levels on outlet side (free-field conditions)
Additionally available pressure ⌬pt Pa 씮

Speed Relative acoustic power level


600 Acoustic level Vmax.
Octave center frequency Hz
-6
[rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
750 rpm
400 480 86 72 52 85 77 75 70 67 62 57 51
710 96 86 66 91 88 85 84 82 78 73 68
-8 940 101 93 73 94 99 91 89 89 86 81 77
200 1470 110 104 84 101 107 99 97 98 98 94 89

LpA: Average sound pressure level at 4 m distance (free field)


Measuring surface S = 101 (m2)
5000 10000 15000 20000 25000 30000 35000 Measuring surface level: Ls = 20 (dB)
Volume flow V m3/h 씮

1500 rpm BVW 630/30 Model Speed Motor Nominal Flange dia
Max. weight approx
Motor size

output current at
BVW-A
2000 400 V-50 Hz
Pressure losses BVW-R
kW approx A BVW-R BVW-R
––– Inlet box BVW-D rpm BVW-A
BVW-D **
- - - BVW-D damper
1800 ....... BVW-A or 630/30-6 940 5,5 12,7 132 300
R damper 630/30-4 1470 18,5 35 180 300
630/30-4/8 1460/710 20/5,5 39/16,2 180 300 460 385 474
1600
630/30-6/12 975/480 6,3/1,5 15,7/5,4 160 300
␦ 630/30-6/8/12 970/735/475 6,0/3,0/1,5 11,9/9,5/4,4 160 300
= 1,2 kg/m3
t = 20°C
1400
BVW

* for motor size 180


1200
** BVW-R with inlet duct
-4

1000

1000 rpm

800
Acoustic levels on outlet side (free-field conditions)
Additionally available pressure ⌬pt Pa 씮

Speed Relative acoustic power level


600 Acoustic level Vmax.
750 rpm Octave center frequency Hz
-6
[rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000

400 440 86 78 58 83 77 75 75 73 71 67 62
720 94 88 68 87 90 83 82 81 82 79 74
940 99 94 74 92 95 89 86 86 88 87 82
-8
200 1470 107 103 83 99 98 103 95 93 97 98 95

LpA: Average sound pressure level at 4 m distance (free field)


Measuring surface S = 101 (m2)
5000 10000 15000 20000 25000 30000 35000
Measuring surface level: Ls = 20 (dB)
Volume flow V m /h 씮
3
WALL MOUNTING SMOKE EXHAUST FANS
BVW-A · BVW-R · BVW-D SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany


600 °C – 120 MIN 154
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

BVW 710/30 Model Speed Motor Nominal


Max. weight approx

Flange dia
Motor size
1500 rpm output current at
BVW-A
Pressure losses 400 V-50 Hz
1800 BVW-R
kW approx A BVW-R BVW-R
––– Inlet box BVW-D rpm BVW-A
BVW-D **
- - - BVW-D damper
....... BVW-A or 710/30-6 940 5,5 12,7 132 300
1600 R damper
710/30-4 1470 18,5 36 180 300
710/30-4/8 1460/710 20/5,5 39/16,2 180 300 570 475 605
710/30-6/12 975/475 6,3/1,5 14/4,8 160 300

1400 = 1,2 kg/m3 710/30-6/8/12 970/725/475 7,5/4,0/1,85 16,2/10/7,1 180 300
t = 20°C

1200

-4 * for motor size 180


** BVW-R with inlet duct
1000

800
1000 rpm

Acoustic levels on outlet side (free-field conditions)


Additionally available pressure ⌬pt Pa 씮

600
Speed Relative acoustic power level
Acoustic level Vmax.
Octave center frequency Hz
750 rpm
400 [rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
-6 475 91 82 62 89 83 81 80 77 73 68 63
-8 715 98 90 70 91 95 88 87 86 83 78 73
200 950 104 99 79 97 101 94 92 94 93 88 83
1470 113 109 89 104 103 109 101 102 104 100 96

LpA: Average sound pressure level at 4 m distance (free field)


Measuring surface S = 101 (m2)
7500 10000 15000 20000 25000 30000 35000 40000 45000
Measuring surface level: Ls = 20 (dB)
Volume flow V m3/h 씮

Minimum cooling air flow rate [m3/h]


Fan Nominal motor speed [rpm]
size 3000 1500 1000
315 655 335 250
355 – 380 285
400 – 435 327
500 – 500 375
630 – 1500 1125
710 – 1500 1125
– 155 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Centrifugal Smoke Exhaust Fan, BVW-A series

for the extraction of smoke fumes of


max. 600°C / 120 min.
tested to EN 12101, Part 3 (Technical University of Munich)
with general building supervision approval Z-78.1-29
For installation outside the fire zone.
Motor cooled with ambient air not exceeding 40°C
Direct-drive type, consisting of
steel sheet housing, protected by
polyester powder coating, colour RAL 7030,
with inlet nozzle, motor support plate,
companion flange as per DIN 24154, Series R3
companion frame as per DIN 24193, Series R2
smoke inlet box
(without motor enclosure).
Centrifugal impeller, single inlet type, aerodynamically
optimized,
dynamically balanced to DIN ISO 1940
quality grade G 6,3
welded sheet steel construction with polyester powder
coating, colour: RAL 7030
For wall-mounting installation
or For floor-standing installation.
Three-phase motor as per IEC standard, style V 3 / B 5
Protection class IP 55
Insulation material grade H
Specifications:
Volume flow m3/h
Temperature (design) °C
Max. temperature / withstand time 600°C/120 min.
Additionally available pressure Pa
Three-phase motor
single-speed
or with Dahlander pole-changing winding
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Motor winding V
Current consumption A
Operating voltage V
BVW

Frequency Hz
Total sound pressure level LW dB
Weight of fan with accessories kg

Manufacturer: TLT-Turbo GmbH

Type: BVW-A ....

Carryover
– 156 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment

• Set of installation jigs*

• Flexible connector, inlet side*


(temperature-resistant)
- round
or - rectangular

• Flexible connector, outlet side*


temperature-resistant, rectangular

• Matching frame * DIN 24193, Series R2

• Matching flange, * DIN 24154, Series R3

• Set of spring-type antivibration mounts*

• Outlet duct including wire guard and self-activating


shutoff damper

• Inlet duct (not compatible with inlet box)

• Duct section with self-activating shutoff damper*


(with 2 frames)

• Floor mounting baseframe

• Wall transition sleeve (adjustable),


max. 390 mm wall thickness

• Inlet wire guard (rectangular)

Note: Please observe our Installation, Operating and


Maintenance Instructions (available upon request).

* Loosely supplied
Carryover
– 157 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Centrifugal Smoke Exhaust Fan, BVW-R series

for the extraction of smoke fumes of


max. 600°C / 120 min.
tested to EN 12101, Part 3 (Technical University of
Munich)
with general building supervision approval Z-78.1-29
Motor requires outside air cooling.
For installation within the fire zone.
Direct-drive type, consisting of
steel sheet housing, protected by
polyester powder coating, colour RAL 7030,
with inlet nozzle, motor support plate,
companion flange as per DIN 24154, Series R3
companion frame as per DIN 24193, Series R2
Centrifugal impeller, single inlet type, aerodynamically
optimized,
dynamically balanced to DIN ISO 1940
quality grade G 6,3
welded sheet steel construction with polyester powder
coating, colour: RAL 7030
For wall-mounting installation
or For floor-standing installation.
Three-phase motor as per IEC standard, style V 3 / B 5
Protection class IP 55
Insulation material grade H
Motor enclosure:
Round sheet steel housing, cooling air supplied via
cooling air inlet duct.
Max. length of outside air supply line: 1,0 m.
Specifications:
Volume flow m3/h
Temperature (design) °C
Max. temperature / withstand time 600°C/120 min
Additionally available pressure Pa
Three-phase motor
single-speed
or with Dahlander pole-changing winding
BVW

or pole-changing type with separate windings


Motor speed rpm
Motor output kW
Motor winding V
Current consumption A
Operating voltage V
Frequency Hz
Total sound pressure level LW dB
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH

Type: BVW-R ....

Carryover
– 158 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment

• Set of installation jigs*

• Flexible connector, inlet side*


(temperature-resistant)
- round
or - rectangular

• Flexible connector, outlet side*


temperature-resistant, rectangular

• Flexible connector for cooling air duct

• Inlet box

• Matching frame * DIN 24193, Series R2

• Matching flange, * DIN 24154, Series R3

• Set of spring-type antivibration mounts*

• Inlet duct

• Outlet duct connector including wire guard and self-


activating shutoff damper*

• Duct section with self-activating shutoff damper*


(with 2 flanges)

• Floor mounting baseframe

• Wall transition sleeve (adjustable),


max. 390 mm wall thickness

• Wall transition sleeve for cooling air duct (adjustable)


max. 390 mm wall thickness

• Inlet wire guard (rectangular)

Note: Please observe our Installation, Operating and


Maintenance Instructions (available upon request).
Carryover

* Loosely supplied
– 159 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Centrifugal Smoke Exhaust Fan, BVW-D series

for the extraction of smoke fumes of


max. 600°C / 120 min.
tested to EN 12101, Part 3 (Technical University of
Munich)
with general building supervision approval Z-78.1-29
Snow load class SL 1000
For roof installation, motor requiring outside air cooling
via an external air supply duct.
Direct-drive type, consisting of
steel sheet housing, protected by
polyester powder coating, colour RAL 7030,
with inlet nozzle, motor support plate,
companion flange as per DIN 24154, Series R3
companion frame as per DIN 24193, Series R2
Centrifugal impeller, single inlet type, aerodynamically
optimized,
dynamically balanced to DIN ISO 1940
quality grade G 6,3
welded sheet steel construction with polyester powder
coating, colour: RAL 7030
For wall-mounting installation
or For floor-standing installation.
Three-phase motor as per IEC standard, style V 3 / B 5
Protection class IP 55
Insulation material grade H
Motor enclosure:
Round sheet steel housing, cooling air supplied via
cooling air inlet duct.
Specifications:
Volume flow m3/h
Temperature (design) °C
Max. temperature / withstand time 600°C/120 min.
Additionally available pressure Pa
Three-phase a.c. motor
single-speed
or Dahlander pole-changing type
BVW

or pole-changing type with separate windings


Motor speed rpm
Motor output kW
Motor winding V
Current consumption A
Operating voltage V
Frequency Hz
Total sound pressure level LW dB
Weight of fan with accessories kg

Manufacturer: TLT-Turbo GmbH

Type: BVW-D .... Carryover


– 160 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment:

• Shutoff damper, outlet side


Snow load class SL 1000

• Roof mounting base, made of galvanised sheet steel,


insulated* (height: 350 mm)

• Round duct connector, inlet side

• Matching flange, inlet side*

• Flexible connector, inlet side*


(temperature-resistant)

Note: Please observe our Installation, Operating and


Maintenance Instructions (available upon request).

* Loosely supplied
CENTRIFUGAL SMOKE EXHAUST FANS
PRODUCT RANGE 
TECHNICAL DESCRIPTION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 161
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Characteristic curves as of page 170 Characteristic curves as of page 180


BV-REH series (insulated casing) BVRA series
Temperature/Time category acc. to Temperature/Time category acc. to
EN 12101 - part 3: EN 12101 - part 3:

Centrifugal smoke exhaust fans BV-REH/BVRA series


F 400 400°C - 120 min. F 600 620°C - 90 min.
Appropriate for installation outside Appropriate for installation outside
of fire-zone. of fire-zone.
Alos available with acoustic and Alos available with acoustic and
thermal insulation. thermal insulation.

Product range: Product range:


13 sizes 19 sizes
inlet ranging from 400-1600 mm inlet ranging from 180 - 1400 mm
diam. diam.
Volume flow up to 125 000 m3/h Volume flow up to 140 000 m3/h
total pressure increase total pressure increase
up to appr. 3 500 pa up to appr. 3 150 Pa

Technical description Technical description


BV-REH series BVRA series
Casing of rugged, welded construc- Casing of rugged, welded construc-
tion with stiffened lateral panels, in- tion with stiffened lateral panels. Out-
cluding outlet frame and inlet flange. let with DIN 24158, part 3 flanges. In-
Connecting dimensions in accordan- let with DIN 24154, part 3, flanges.
ce with DIN 24193 - Series 2 (Euro
standard) or DIN 24154, Series 3. Centrifugal impeller, single inlet type,
High-performance impeller of welded of welded sheet steel construction,
steel construction, with backward cur- dynamically balanced to DIN ISO
ved blades, energy-optimized for ma- 1940 quality grade G 6.3.
ximum effficiency. Rounded-edge Fan shaft with cooling disc and shaft
bellmouth made of flow formed sheet seal, supported in pedestal bearings.
steel, aerodynamically matched to V-belt drive complete with two pul-
impeller. Shaft impeller in two self-ali-
leys, V-belt and guard. Casing coated
gning ball (or roller) bearings moun-
ted in split cast-iron bearing pede- with temperature-resistant aluminium
stals. Impeller with Taperlock hub and paint (for indoor installation).
shaft jointly balanced to DIN ISO
1940 - G 2.5 standard. Fitted on a
rugged bearing. Surface finished with
powder coating or high-grade 1-com-
ponent synthetic coating. Colour:
RAL 7030.
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
MAIN DIMENSIONS SIZES 400 TO 630
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C - 120 MIN 162
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

130 B Optional or to be H
provided by installer:
E G
thermal and acoustic insulation

for connecting dimensions


see page 167/168
F
F1
I
A
D

See dimensional table

Ødh6
for max. motor size
C

180

h
LG90° (RD90°)
Gmax. J
Lmax. K

Casing position LG0¡ (RD0¡)* LG 180¡ (RD 180¡)* LG 270¡ (RD 270¡)*
B
A E
A
E

A
B
B
E

Gmax. Gmax.2) Gmax.


Lmax. Lmax.2) Lmax.
Isu- 0° 90°/270° appr.
Size A B C D E F F1 G H I K Ødh6 appr. lation Motor h J Lmax. Gmax.
kg 1) appr. kg sizes Lmax. Gmax. kg
90-112 65 1350 1305 1250 1205 34
400 776 670 306 179 369 340 502 282 362 582 970 30 90 45 646
132-180 80 1600 1555 1400 1355 46
90-112 65 1500 1455 1350 1305 36
450 874 755 351 202 410 380 562 317 397 642 1005 30 105 50 683
132-180 80 1650 1605 1500 1455 48
90-112 65 1600 1555 1450 1405 38
500 957 827 380 221 457 425 632 357 437 712 1102 40 140 55 132-180 80 778 1750 1705 1600 1555 50
200 100 1850 1805 1700 1655 67
90-112 65 1700 1655 1550 1505 40
560 1070 920 427 247 509 477 712 402 482 792 1147 40 170 64 132-180 80 821 1850 1805 1700 1655 53
200 100 1950 1905 1800 1755 70
90-112 80 1800 1755 1650 1605 52
630 1211 1026 479 291 574 550 802 452 532 882 1227 40 205 80 132-180 100 901 1950 1905 1800 1755 68
200,225 120 2050 2005 1900 1855 82
1) Without motor/without *Mirror-inverted Dimensional and design changes reserved Dimensions in mm
baseframe without V-belt drive casing position 2) please ask
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
MAIN DIMENSIONS SIZES 710 TO 1000
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C - 120 MIN 163
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

B Optional or to be H
130
provided by installer: G
E thermal and acoustic insulation

for connecting dimensions


see page 167/168
F
F1
I
A
D

See dimensional table

Ødh6
for max. motor size
C

180

h
LG90° (RD90°)
Gmax. J

Lmax. K

Casing position LG0¡ (RD0¡)* LG 180¡ (RD 180¡)* LG 270¡ (RD 270¡)*
B

A E
A
E

A
B

B
E

BV-REH

Gmax. Gmax.2) Gmax.


Lmax.2) Lmax.

Isu- 0° 90°/270° appr.


Size A B C D E F F1 G H I K Ødh6 appr. lation Motor h J Lmax. Gmax.
kg 1) appr. kg sizes Lmax. Gmax. kg
90-160 100 2100 2100 1900 1845 80
710 1343 1153 539 313 647 600 899 502 586 983 1312 50 325 120 989
180-225 140 2300 2300 2000 1945 120
90-160 100 2200 2200 2100 2025 85
800 1505 1290 604 359 726 673 999 559 643 1083 1369 50 390 180 1046
180-225 140 2400 2400 2400 2325 130
112-160 100 2400 2400 2200 2135 95
900 1703 1445 674 407 811 7551119 629 753 1243 1469 55 495 200 180-225 140 1156 2600 2600 2400 2335 140
250 160 3000 3000 2800 2735 160
112-160 100 2600 2600 2400 2330 105
1000 1871 1576 746 438 894 8481249 712 836 1373 1645 55 590 240 180-225 140 1337 2800 2800 2600 2530 160
250 160 3200 3200 3000 2930 190

1) Without motor/without *Mirror-inverted Dimensional and design changes reserved Dimensions in mm


baseframe without V-belt drive casing position 2) please ask
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
MAIN DIMENSIONS SIZES 1120 TO 1600
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C - 120 MIN 164
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

200 B H
Optional or to be
E provided by installer: G
thermal and acoustic insulation

for connecting dimensions


see page 167/168
F
I
D
A

See dimensional table

Ødh6
for max. motor size
C

200

h
LG90° (RD90°)
Gmax. J
Lmax. K

Casing position LG0¡ (RD0¡)* LG 180¡ (RD 180¡)* LG 270¡ (RD 270¡)*
B
E
A A
E

A
B

B
E

Gmax. Gmax.2) Gmax.


Lmax. Lmax.2) Lmax.

Isu- 0° 90°/270° appr.


Size A B C D E F G H I K Ødh6 appr. lation Motor h J Lmax. Gmax.
kg 1) appr. kg sizes Lmax. Gmax. kg
112-180 120 3100 2970 2800 2670 155
1120 2350 2072 974 813 11621002 802 922 1124 1756 55 870 300 200-250 160 1436 3300 3170 3100 2970 220
280 180 3500 3370 3300 3170 260
160-180 120 3400 3270 3100 2970 185
1250 2625 2320 1088 911 12971122 902 1028 1248 2056 65 1170 330 200-250 160 1733 3600 3470 3300 3170 260
280 180 3800 3670 3500 3370 300
160-180 120 3700 3570 3400 3270 200
1400 2930 2600 1218 1023 14551252 1002 1128 1378 2137 70 1485 384 200-250 160 1834 3900 3770 3600 3470 280
280-315 180 4100 3970 3800 3670 325

1) Without motor/without *Mirror-inverted Dimensional and design changes reserved Dimensions in mm


baseframe without V-belt drive casing position 2) please ask
CENTRIFUGAL SMOKE EXHAUST FANS
BV-REH SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 165
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Inspection hatch The inspection hatch meets accident Acoustic and thermals
Arranged in accordance with casing prevention rules. It can only be ope- insulation for centrifugal smoke
orientation. Available in two versions: ned by using tools. exhaust fans
B The position of this hatch depends  Mineral fibre mats, stitched with
A
on casing orientation. galvanized wire onto galvanized
A Standard version, fitted with self- wire netting on one side
tapping screws.  Rigid support structure, 120 mm
B Industrial version with handle, shell spacing
attached via backwelded nuts  Outer protective shell consisting of
and hexagonal head screws. 1.0 mm gauge smooth sheet steel,
galvanized on both sides. For out-
door installation, an additional pro-
tective lacquer coating is applied
(for extra charge please see tariff).
 Connections are designed to facili-
Drain connection
tate dismantling and refitting. Hori-
(Please specify casing orientation in
zontally and vertically split versions
purchase order).
are available (for extra charge
Fan sizes up to 1000:
please see tariff).
R 1/2” female thread connection
Fan sizes of 1120 and higher:  Technical details based on DIN
R1” female thread connection 18421 and DIN 4102 standard spe-
Fitted at lowest point of casing. cifications, respectively.
 Damping effect: approx. 12 dB
(acoustic emission from fan ca-
sing)

Shaft cover Antivibration mounts


for the exterior shaft end

Spring-type version

Please inquire reg. number


and sizes.
BV-REH

Belt guard Belt drive


Complete belt drive consists of the
following components:
 2 pulleys in accordance with DIN
2211
 1 set of high-performance narrow
Also available in horizontally split V-belts according to DIN 7753
versions by special order.
 Optionally: flat belt drive

For additional accessories refer to  Flexible connector


page 166 – 168
 Matching angular frame
 Matching flange
 Outlet box
CENTRIFUGAL SMOKE EXHAUST FANS
BV-REH SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 166
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Outlet box for outdoor installation


(90° casing position)
a
c
e1 z1xt1 e1 h
g e

Ø 12
zxf

f/g
d
f

Bird screen made


of wire netting
2.5 x 20 mm,
galvanized steel
e

100

Size a c g z1xt1 e1 b d f zxt e h

400 362 326 282 - 163 582 546 502 3x125 85,5 334

450 397 361 317 1x125 118 642 606 562 3x125 115,5 362

500 437 401 357 1x125 138 712 676 632 3x125 150,5 395

560 482 446 402 1x125 160,5 792 756 712 5x125 65,5 432

630 532 496 452 3x125 60,5 882 846 802 5x125 110,5 474

710 582 546 502 3x125 85,5 982 946 902 5x125 160,5 521

800 642 606 562 3x125 115,5 1082 1046 1002 7x125 85,5 567

900 752 702 632 3x125 163,5 1242 1192 1122 7x125 158,5 623

1000 832 782 712 5x125 78,5 1372 1322 1252 9x125 98,5 684

1120 922 872 802 5x125 123,5 1124 1072 1002 7x125 98,5 567

1250 1022 972 902 5x125 173,5 1242 1192 1122 7x125 158,5 623

1400 1122 1072 1002 7x125 98,5 1372 1322 1252 9x125 98,5 684

1600 1242 1192 1122 7x125 158,5 1522 1472 1402 9x125 173,5 754
Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C-120 MIN 167
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

a
❶ Matching flange ❷ Flexible connector,
rectangular
c

e1
e1 z1 x t1
e

x
zxt
d
b

ØD
w

*
x
e

s
L

BV-REH

Size a c g z1 x t1 e1 b d f zxt e w x ØD s L ❶ ❷
appr. (kg) appr. (kg)
400 362 326 282 – 163 582 546 502 3 x 125 85,5 22 40 12 4 130 8,0 4,0
450 397 361 317 1 x 125 118 642 606 562 3 x 125 115,5 22 40 12 4 130 8,5 5,0
500 437 401 357 1 x 125 138 712 676 632 3 x 125 150,5 22 40 12 4 130 9,0 5,0
560 482 446 402 1 x 125 160,5 792 756 712 5 x 125 65,5 22 40 12 4 130 10 6,0
630 532 496 452 3 x 125 60,5 882 846 802 5 x 125 110,5 22 40 12 4 130 12 6,0
710 582 546 502 3 x 125 85,5 982 946 902 5 x 125 160,5 22 40 12 4 130 12,5 7,0
800 642 606 562 3 x 125 115,5 1082 1046 1002 7 x 125 85,5 22 40 12 4 130 13 8,0
900 752 702 632 3 x 125 163,5 1242 1192 1122 7 x 125 158,5 35 60 12 6 130 15 20
1000 832 782 712 5 x 125 78,5 1372 1322 1252 9 x 125 98,5 35 60 12 6 130 17 23
1120 922 872 802 5 x 125 123,5 1124 1072 1002 7 x 125 98,5 35 60 12 4 200 18,5 7,0
1250 1022 972 902 5 x 125 173,5 1242 1192 1122 7 x125 158,5 35 60 12 6 200 20 12
1400 1122 1072 1002 7 x 125 98,5 1372 1322 1252 9 x 125 98,5 35 60 12 6 200 23 13

* Burgert-Type Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C-120 MIN 168
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

C
❶ Matching flange ❷ Flexible connector,
B round

z x ød

s
L

Size ØA ØB ØC Z x ød s L ❶ ❷
appr. (kg) appr. (kg)
400 403 438 464 12 x 9,5 6 180 2,0 5,2
450 452 487 513 12 x 9,5 6 180 2,0 5,8
500 506 541 567 12 x 9,5 6 180 2,0 6,6
560 568 605 639 16 x 11,5 6 180 3,0 8,2
630 637 674 708 16 x 11,5 6 180 3,5 9,2
710 714 775 814 16 x 14 8 180 7,0 16,5
800 804 861 904 24 x 14 8 180 8,0 19,2
900 904 958 1004 24 x 14 8 180 9,0 21,3
1000 1005 1067 1105 24 x 14 8 180 10 23,8
1120 1005 1067 1105 24 x 14 8 200 10 25,8
1250 1125 1200 1245 32 x 18 10 200 17 26
1400 1255 1337 1375 32 x 18 10 200 19 40

Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
BV-REH SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 169
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Acoustic level Starting from this value, the A-weighted acoustic power emitted from the fan inlet or outlet
power level LWA and the relative acoustic power opening, respectively. The values given were
The total acoustic power level Lwvent of an axial- taken from measurements as per EN 25136
level LW rel. can be determined using the tables
flow fan can be obtained directly from the (formerly DIN 45 635, Part 9) duct testing method.
below. These values are available as the acoustic
characteristic data sheets for each operating
power emitted into the duct and as the acoustic
point.

Acoustic power level emitted into the duct Acoustic power emitted from the fan inlet or outlet opening
The level of acoustic power an axial-flow fan emits into the ducting is To determine the sound levels at a given installation site, it is usually
used for calculating the sound power characteristics of downstream necessary to know the level of acoustic power emitted from the fan's
systems, e.g., silencers. The levels are calculated as follows: inlet or outlet opening. The tables below are based on the outlet
reflection pattern assumed in VDI 2081, Case 2.
Lwvent. (dB) = total acoustic power emitted by the fan, (please see
respective characteristic curve sheets) LwA op. (dB) = A-weighted level of acoustic power emitted from the
fan's opening, expressed by the equation
LwA vent. (dB) = A-weighted acoustic power level, according to the
equation LwA op. = Lwvent – portion 2.1 (dB)

LwA vent. = Lwvent – portion 1.1 (dB) Lwrel op.(dB) = relative level of acoustic power emitted from the fan's
opening, expressed by the equation
Lwrel vent. (dB) = relative acoustic power level as expressed by the
equation Lwrel op. = Lwvent – portion 2.2 (dB)

LwA rel vent. = Lwvent – portion 1.2 (dB) LW Op. (dB) = Unweighted (linear) level of acoustic power emitted
from the fan's opening, expressed by the equation
LW Op. = Lwvent – portion 2.3 (dB)

Size
Ventilator- Drehzahl
Fan Anteil
Speed Portion Anteil 1.2 1.2
Portion beiatOktavmittenfrequenz [Hz]
mid-octave frequency [Hz] Size
Ventilator- Drehzahl Anteil
Fan Speed Portion Anteil 2.2 2.2
Portion beiatOktavmittenfrequenz [Hz]
mid-octave frequency [Hz] Anteil
Portion
Baugröße [min -1 Baugröße [min -1
[rpm] ] 1.1
1.1 63
63 125
125 250
250 500
500 1000
1000 2000
2000 4000
4000 8000
8000 [rpm]] 2.1
2.1 63
63 125
125 250
250 500
500 1000
1000 2000
2000 4000
4000 8000
8000 2.3
2.3

400 1250 11 5 8 4 11 20 25 30 35 400 1250 12 18 15 7 12 20 25 30 35 5


1600 9 5 8 4 12 16 23 28 33 1600 10 18 15 6 12 16 23 18 33 4
2000 7 6 8 4 11 14 20 25 30 2000 8 18 15 6 11 14 20 25 30 3
2500 6 6 8 11 4 11 18 23 28 2500 6 19 15 13 5 11 18 23 28 3
3150 5 6 8 11 4 11 14 20 25 3150 5 19 15 13 5 11 14 20 25 2
450 1120 12 5 3 9 14 20 25 30 35 450 1120 13 17 8 11 15 20 25 30 35 5
1400 10 5 8 4 11 18 23 28 33 1400 11 17 14 7 11 18 23 28 33 4
1800 8 5 8 4 11 14 20 25 30 1800 9 17 14 6 11 14 20 25 30 3
2240 7 6 8 4 11 13 18 23 28 2240 7 18 14 5 11 13 18 23 28 3
2800 5 6 9 11 4 10 15 20 25 2800 6 18 14 13 5 10 15 20 25 2
500 1000 12 5 3 9 14 20 25 30 35 500 1000 13 16 7 11 15 20 25 30 35 4
1250 10 5 8 4 11 18 23 28 33 1250 11 16 13 6 11 18 23 28 33 4
1600 8 5 8 4 11 14 20 25 30 1600 9 16 13 5 11 14 20 25 30 3
2000 7 6 8 4 11 13 18 23 28 2000 7 17 13 5 11 13 18 23 28 3
2500 5 6 8 11 4 10 15 20 25 2500 6 17 14 12 5 10 15 20 25 2
560 900 12 5 3 10 14 20 25 30 35 560 900 13 15 7 11 14 20 25 30 35 5
1120 11 5 3 9 13 18 22 27 33 1120 11 15 7 10 13 18 22 27 33 4
1400 9 5 8 4 11 16 20 25 30 1400 10 15 12 6 11 16 20 25 30 3
1800 7 6 8 4 11 13 18 23 28 1800 8 16 13 5 11 13 18 23 28 3
2240 6 6 8 4 11 12 15 20 25 2240 6 16 13 5 11 12 15 20 25 2
630 800 12 5 3 10 14 20 25 30 35 630 800 13 14 7 11 14 20 25 30 35 4
1000 11 5 3 9 13 18 22 27 33 1000 11 14 6 10 13 18 22 27 33 3
1250 9 5 8 4 11 16 20 25 30 1250 9 14 12 5 11 16 20 25 30 3
1600 7 6 8 4 11 13 18 23 28 1600 8 15 12 5 11 13 18 23 28 2
2000 6 6 8 4 11 12 15 20 25 2000 6 15 12 5 11 12 15 20 25 2
710 710 13 5 3 10 16 20 25 30 34 710 710 14 13 7 10 16 20 25 30 35 4
900 11 5 3 10 13 18 22 27 33 900 12 13 6 10 13 18 22 27 33 3
1120 10 5 3 9 12 16 20 25 30 1120 10 13 6 10 12 16 20 25 30 3
1400 8 6 8 4 10 14 18 22 28 1400 8 13 11 5 10 14 18 22 28 2
BV-REH

1800 7 6 8 4 11 12 15 20 25 1800 7 14 11 5 11 12 15 20 25 2
800 630 13 5 3 10 16 20 25 30 35 800 630 13 12 6 10 16 20 25 30 35 4
800 11 5 3 10 13 18 22 27 33 800 12 12 6 10 13 18 22 27 33 3
1000 10 5 3 9 12 16 20 25 30 1000 10 12 5 8 12 16 20 25 30 2
1250 8 6 8 4 10 14 18 22 28 1250 8 13 11 5 10 14 18 22 28 2
1600 7 6 8 4 11 12 15 20 25 1600 7 13 11 4 11 12 15 20 25 2
900 560 13 2 7 11 16 20 24 30 35 900 560 14 7 9 11 16 20 24 30 35 4
710 12 5 3 10 14 17 22 27 32 710 12 11 6 10 14 17 22 27 32 3
900 10 5 3 10 13 15 20 25 30 900 10 11 5 10 13 15 20 25 30 2
1120 9 5 3 10 12 14 18 22 28 1120 9 12 5 10 12 14 18 22 28 2
1400 7 6 8 4 11 12 15 20 25 1400 7 12 10 5 11 12 15 20 25 2
1000 500 13 2 7 11 16 20 24 30 35 1000 500 14 6 9 11 16 20 24 30 35 3
630 12 5 3 10 14 17 22 27 32 630 12 10 5 10 14 17 22 27 32 3
800 10 5 3 10 13 15 20 25 30 800 10 10 5 10 13 15 20 25 30 2
1000 9 5 3 10 12 14 18 22 28 1000 9 11 4 10 12 14 18 22 28 2
1250 7 6 8 4 11 12 15 20 25 1250 7 11 10 4 11 12 15 20 25 1
1120 450 12 1 9 12 14 16 21 26 31 1120 450 12 4 10 12 14 16 21 26 31 2
560 10 2 9 12 13 14 19 24 29 560 10 4 10 12 13 14 19 24 29 2
710 8 10 2 10 13 13 16 21 26 710 9 13 3 10 13 13 16 21 26 1
900 7 10 2 10 12 11 14 19 24 900 7 13 3 10 12 11 14 19 24 1
1120 6 10 2 11 12 11 12 16 21 1120 6 13 3 11 12 21 12 16 21 –
1250 400 12 1 9 12 14 16 21 26 31 1250 400 12 5 10 12 14 16 21 26 31 2
500 10 2 9 12 13 14 19 24 29 500 10 4 10 12 13 14 19 24 29 2
630 9 2 9 12 13 13 16 21 26 630 9 3 10 12 13 13 16 21 26 1
800 7 10 2 10 13 11 14 19 24 800 7 12 3 11 13 11 12 16 21 1
1000 6 10 2 11 13 11 12 16 21 1000 6 13 3 11 13 11 12 16 21 –
1400 355 12 1 9 12 14 16 21 26 31 1400 355 12 4 10 12 14 16 21 26 31 2
450 10 2 9 12 13 14 19 24 29 450 10 4 10 12 13 14 19 24 29 2
560 9 2 9 12 13 13 16 21 26 560 9 3 10 12 13 11 14 19 24 1
710 7 10 2 10 13 11 14 19 24 710 7 12 3 10 13 11 14 19 24 1
900 6 10 2 11 13 11 12 16 21 900 6 12 3 11 13 11 12 16 21 –

Note: Portions 1.1/ 1.2 /2.1/ 2.2/ 2.3 to be taken frome the above spreadsheets
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C - 120 MIN 170


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Moment of inertia J = 0,13 kgm2 Number of blades z = 9 Moment of inertia J = 0,19 kgm2 Number of blades z = 9
Impeller diameter D2 = 398 mm Free discharge area F = 0,141 m2 BV-REH 400 Impeller diameter D2 = 447 mm Free discharge area F = 0,178 m2 BV-REH 450
Efficiency ␩ =
0,63

t = 20°C
0,72

5000 5000 Efficiency ␩ =

0,63
0,76
t = 20°C

0,72
❶ ␦
= 1,2 kg/m3

0,76
nmax. = 3740 rpm
4500 0,80
4500 ❶ nmax. = 3330 rpm ␦
= 1,2 kg/m3

0,80
4000 ❷ nmax. = 3600 rpm 4000
0,81
❷ nmax. = 3200 rpm

0,81
3550 105 3550
106
3150
0,76
3150
]

]
[dB

[dB

0,76
2800 2800

Tip speed u2 [m/s]


Fan speed n [rpm]

Tip speed u2 [m/s]


t

Fan speed n [rpm]


ven

t
ven
102 2500
2500 0,64
103
w

w
l L

l L

0,64
2240 2240
leve

leve
2000 99 2000 100
wer

wer
1800 1800
0,48
o

0,48
o
0,61
tic p

0,70

tic p
1600 1600

0,61
0,74

0,70
97

0,74
ous

1400
0,78

1400

ous
98

0,78
l ac

l ac
1250 1250
0,79

94
Tota

4000 83

0,79
Tota
1120 1120 95 3550 83
1000 1000
0,74

0,74
900 3550 74 900 3150 74
91
800 800 92
0,62

3150 66

0,62
710 710 2800 66
630 88 630
2800 58 89
560 560 2500
0,46

58

0,46
500 500
450 85 2500 52 450 2240 52
82 86
400 400 83
Overall pressure increase ⌬pt1 [Pa] ➞

Overall pressure increase ⌬pt1 [Pa] ➞

355 2240 47 355 2000 47


315 315
280 2000 42 280 1800 42
250 250
224 1800 37 224 1600 37
200 Power requirement at shaft: 200 Power requirement at shaft:
180 1600 33 180 1400 33
160 V [m3/h] · ⌬pt [Pa] 160 V [m3/h] · ⌬pt [Pa]
Pw [kW] = 1400 Pw [kW] =
140 ␩· 1000 · 3600
29 140 ␩· 1000 · 3600 1250 29
125 125
112 1250 26 112 1120 26
1 120
1 250
1 400
1 600
1 800
2 000
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000

1 400
1 600
1 800
2 000
2 240
2 500
2 800
3 150
3550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
Volume flow rate* Volume flow rate*
V [m3/h]
V [m3/h]
Volume flow rate*
2,8 0,4
3,15 0,45
3,55 0,5
4,0 0,56
4,5 0,63
5,0 0,71
5,6 0,8
6,3 0,9
7,1 1,0
8,0 1,12
9,0 1,25
10 1,4
11,2 1,6
12,5 1,8
14 2,0
16 2,24
18 2,5
20 2,8
22,4 3,15
25 3,55
28 4,0
35,5 4,5
2,24 0,315
2,5 0,355

Volume flow rate*


0,4
0,45
0,5
0,56
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pd [Pa] pd [Pa]

❶ nmax. if only used in case of fire / ❷ nmax. if used for ventilation (continuous service). Do not select in grey screened fields

Moment of inertia J = 0,39 kgm2 Number of blades z = 9 Moment of inertia J = 0,61 kgm2 Number of blades z = 9
Impeller diameter D2 = 501 mm Free discharge area F = 0,225 m2 BV-REH 500 Impeller diameter D2 = 562 mm Free discharge area F = 0,286 m2 BV-REH 560
5000 Efficiency ␩ =
0,63

Efficiency ␩ = 5000
0,63

t = 20°C
0,72

t = 20°C
0,72

0,76
0,76

4500 ❶ nmax. = 2970 rpm ❶ nmax. = 2650 rpm


␦ 4500 ␦
= 1,2 kg/m3 = 1,2 kg/m3
0,80
0,80

4000 4000
❷ nmax. = 2860 rpm ❷ nmax. = 2550 rpm
0,82
0,82

3550 3550 108


107
3150 3150
]
[dB

0,76
0,76

[dB

2800 2800
Tip speed u2 [m/s]

Tip speed u2 [m/s]


Fan speed n [rpm]

Fan speed n [rpm]


t
ven

t
ven

2500 104 2500 105


Lw

0,64
Lw
0,64

2240 2240
l
leve

el

2000
r lev

101 2000 102


wer

1800 1800
owe

0,48
0,48
c po

1600 1600
0,61
tic p
0,61

0,70
0,70
ti

0,74
0,74

1400
ous

99 1400 100
ous

0,78
0,78
l ac

1250 1250
l ac

0,80
0,80
Tota

1120 3150 83 2800 83


Tota

96 1120 97
1000 1000
0,74
0,74

900 2800 74 900 2500 74


800 93 800 94
0,62
0,62

710 2500 66 710 2240 66


630 90 630 91
560 2240 58 560 2000 58
0,46
0,46

500 500
450 87 2000 52 450 88 1800 52
400 84 400 85
Overall pressure increase ⌬pt1 [Pa] ➞

Overall pressure increase ⌬pt1 [Pa] ➞

355 1800 47 355 1600 47


315 315
280 1600 42 280 1400 42
250 250
224 1400 37 224 1250 37
* values rounded to standard figures

200 Power requirement at shaft: 200 Power requirement at shaft:


180 1250 33 180 1120 33
160 V [m3/h] · ⌬pt [Pa] 160 V [m3/h] · ⌬pt [Pa]
Pw [kW] = Pw [kW] =
140 ␩· 1000 · 3600 1120 29 140 ␩· 1000 · 3600 1000 29
125 125
112 1000 26 112 900 26
1 800
2 000
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000

2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500

Volume flow rate* Volume flow rate*


V [m3/h] V [m3/h]

Volume flow rate* Volume flow rate*


0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
0,5
0,56
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1

V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5

c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pd [Pa] pd [Pa]
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C - 120 MIN 171


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Moment of inertia J = 1,26 kgm2 Number of blades z = 9 Moment of inertia J = 2,0 kgm2 Number of blades z = 9
Impeller diameter D2 = 631 mm Free discharge area F = 0,362 m2 BV-REH 630 Impeller diameter D2 = 708 mm Free discharge area F = 0,44 m2 BV-REH 710
Efficiency ␩ = Efficiency ␩ =

0,63
0,63
5000 t = 20°C 4000 t = 20°C

0,72
0,72

0,76
0,76
❶ nmax. = 2360 rpm ❶ nmax. = 1750 rpm
4500 ␦ 3550 ␦
= 1,2 kg/m3 = 1,2 kg/m3

0,80
0,80
4000 3150
❷ nmax. = 2270 rpm ❷ nmax. = 1700 rpm

0,82
0,82
3550 109 2800 108
3150 2500

]
]

[dB
[dB

0,76
0,76
2800 2240

Tip speed u2 [m/s]


Fan speed n [rpm]
Tip speed u2 [m/s]
Fan speed n [rpm]

t
t

ven
ven

2500 106 2000 105

w
w

l L

0,64
l L

0,64
2240 1800

leve
leve

2000 103 1600 102

wer
wer

1800 1400

0,48
0,48

o
o

tic p
tic p

1600 1250

0,61
0,61

0,70
0,70

0,74
0,74

ous
ous

1400 101 1120 100

0,78
0,78

l ac
l ac

1250 1000

0,80
0,80

Tota
Tota

1120 98 2500 83 900 97 2000 74


1000 800

0,74
0,74

900 2240 74 710 1800 66


800 95 630 94

0,62
0,62

710 2000 66 560 1600 58


630 92 500 91
560 1800 58 450 1400 52

0,46
0,46

500 400
450 89 1600 52 355 88 1250 47
400 86 315 85

Overall pressure increase ⌬pt1 [Pa] ➞


Overall pressure increase ⌬pt1 [Pa] ➞

355 1400 47 280 1120 42


315 250
280 1250 42 224 1000 37
250 200
224 1120 37 180 900 33
200 Power requirement at shaft: 160 Power requirement at shaft:
180 1000 33 140 800 29
160 V [m3/h] · ⌬pt [Pa] 125 V [m3/h] · ⌬pt [Pa]
Pw [kW] = Pw [kW] =
140 ␩· 1000 · 3600 900 29 112 ␩· 1000 · 3600 710 26
125 100
112 800 26 90 630 23
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000

Volume flow rate* Volume flow rate*


V [m3/h] V [m3/h]

Volume flow rate* Volume flow rate*


0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2

V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5

c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pd [Pa] pd [Pa]

❶ nmax. if only used in case of fire / ❷ nmax. if used for ventilation (continuous service). Do not select in grey screened fields

Moment of inertia J = 3,47 kgm2 Number of blades z = 9 Moment of inertia J = 7,16 kgm2 Number of blades z = 9
Impeller diameter D2 = 794 mm Free discharge area F = 0,55 m2 BV-REH 800 Impeller diameter D2 = 891 mm Free discharge area F = 0,70 m2 BV-REH 900
Efficiency ␩ =
0,64

Efficiency ␩ =
0,63

t = 20°C
0,73

t = 20°C 4000
0,72

4000
0,77
0,76

❶ nmax. = 1560 rpm ␦


= 1,2 kg/m3 3550 ❶ nmax. = 1390 rpm ␦
= 1,2 kg/m3
0,81

3550
0,80

3150 ❷ nmax. = 1500 rpm 3150 ❷ nmax. = 1340 rpm


0,83
0,82

2800 109 2800 110


2500
]

2500
0,77
0,76

[dB
]
[dB

2240 2240
Tip speed u2 [m/s]

Tip speed u2 [m/s]


Fan speed n [rpm]

Fan speed n [rpm]


t
ven

2000 107
t

106
ven

2000
Lw

0,65
0,64
w

1800 1800
l L

el
r lev

1600
leve

1600 103 104


owe

1400 1400
r

0,49
0,48
owe

tic p

0,62

1250
0,61

0,71

1250
0,70
tic p

0,75
0,74

101 1120 102


ous

1120
0,79
0,78
ous

BV-REH
l ac

1000 1000
l ac

0,81
0,80

Tota

98 1800 74 900 99 1600 74


900
Tota

800 800
0,75
0,74

710 1600 66 710 1400 66


95 96
630 630
0,63
0,62

560 1400 58 560 1250 58


500 92 500 93
450 1250 52 450 1120 52
0,47
0,46

400 400
355 89 1120 47 355 90 1000 47
315 86 315 87
Overall pressure increase ⌬pt1 [Pa] ➞

Overall pressure increase ⌬pt1 [Pa] ➞

280 1000 42 280 900 42


250 250
224 900 37 224 800 37
200 200
180 800 33 180 710 33
* values rounded to standard figures

160 Power requirement at shaft: 160 Power requirement at shaft:


140 710 29 140 630 29
125 V [m3/h] · ⌬pt [Pa] 125 V [m3/h] · ⌬pt [Pa]
Pw [kW] = Pw [kW] =
112 ␩· 1000 · 3600 630 26 112 ␩· 1000 · 3600 560 26
100 100
90 560 23 90 500 23
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000

Volume flow rate* Volume flow rate*


V [m3/h] V [m3/h]

Volume flow rate* Volume flow rate*


1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16

V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28

c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500

pd [Pa] pd [Pa]
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C - 120 MIN 172


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Moment of inertia J = 11,3 kgm2 Number of blades z = 9 Moment of inertia J = 19,4 kgm2 Number of blades z = 8
Impeller diameter D2 = 1000 mm Free discharge area F = 0,88 m2 BV-REH 1000 Impeller diameter D2 = 1120 mm Free discharge area F = 0,80 m2 BV-REH 1120
Efficiency ␩ =
0,64

t = 20°C 5000 t = 20°C


0,73

4000 0,77
❶ nmax. = 1240 min. ␦ ␦
3550 = 1,2 kg/m3 4500 = 1,2 kg/m3
❷ nmax. = 1180 min. 0,81
3150 4000 Efficiency ␩ =

0,63
0,83

0,69
0,73
2800 3550

0,77
111

0,82
3150 ❶ nmax. = 1120 rpm

0,85

Tip speed u2 [m/s]


Fan speed n [rpm]
]

2500
[dB

0,77

0,86
2240 2800 ❷ nmax. = 1120 rpm

Tip speed u2 [m/s]


Fan speed n [rpm]

0,83
t
ven

2000 108 2500


w

0,65
l L

0,81
1800 2240

]
[dB
leve

2000 114
1600 105

t
ven
wer

1400 1800
0,49

0,75
o

l L
111
tic p

1600
0,62

1250
0,71

leve
0,75

103 1400 1250 74


ous

1120
0,79

wer
l ac

1000 1250
0,81

o
Tota

1400 74 1120

tic p
900 100 1120 108 66
1000

ous
800
0,75

0,62
1250 66 1000

l ac
900 58

0,68
710

0,72
0,76
97

Tota

0,81
630 800 105

0,84
0,63

1120 58 710 900 52

0,85
560

0,82
500 94 630
450 1000 52 560 800 47

0,80
0,47

101
400 500
355 91 900 47 450 710 42

0,74
315 88 400 98
Overall pressure increase ⌬pt1 [Pa] ➞

Overall pressure increase ⌬pt1 [Pa] ➞

280 800 42 355 630 37


250 315
95 92
224 710 37 280 89 560 33
200 250
180 630 33 224 500 39
160 Power requirement at shaft: 200 Power requirement at shaft:
140 560 29 180 450 26
125 V [m3/h] · ⌬pt [Pa] 160 V [m3/h] · ⌬pt [Pa]
Pw [kW] = Pw [kW] =
112 ␩· 1000 · 3600 500 26 140 ␩· 1000 · 3600 400 23
100 125
90 450 23 112
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000

Volume flow rate* Volume flow rate*


V [m3/h] V [m3/h]

Volume flow rate* Volume flow rate*


1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25

V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28

2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,8
3,55
4,5
5,6
7,1
9,0
11,2
14
18
22,4
28
35,5
45
56
71
90
112
140
180
224
280
355
450
560
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500

pd [Pa] pd [Pa]

❶ nmax. if only used in case of fire / ❷ nmax. if used for ventilation (continuous service). Do not select in grey screened fields

Moment of inertia J = 30 kgm2 Number of blades z = 8 Moment of inertia J = 63 kgm2 Number of blades z = 8
Impeller diameter D2 = 1250 mm Free discharge area F = 1,01 m2
BV-REH 1250 Impeller diameter D2 = 1400 mm Free discharge area F = 1,25 m2 BV-REH 1400
5000 t = 20°C 5000 t = 20°C

4500

= 1,2 kg/m3 4500 = 1,2 kg/m3
4000 Efficiency ␩ = 4000 Efficiency ␩ =
0,63

0,69
0,63

0,69

0,73
0,73

0,77

3550 3550
0,77

❶ nmax. = 1000 rpm


0,82

❶ nmax. = 900 rpm


Tip speed u2 [m/s]
Fan speed n [rpm]
0,82

0,85

3150 3150
0,85

Tip speed u2 [m/s]


Fan speed n [rpm]

0,86

❷ nmax. = 1000 rpm


0,86

2800 2800 ❷ nmax. = 900 rpm


0,83
0,83

2500 2500
116
0,81

115 2240
0,81

2240
]
[dB

2000
]

2000
[dB

t
ven

1800 1800
t

0,75
ven

Lw
0,75

112 113
1600 1600
Lw

el

1120 1400 1000


r lev

1400 74 74
el
r lev

1250
owe

1250
owe

109 1000 66 1120 110 900 66


tic p

1120
tic p

1000 1000
ous

0,62
ous

0,62

0,68

900 900 58 900 800 58


l ac

0,72
0,68
0,72

0,76
0,76

0,81
l ac

800
Tota
0,81

800 107
0,84

106
0,84
Tota

710 710
0,85

710 800 52 52
0,85

0,82
0,82

630 630
560 710 47 560 630 47
0,80

103
0,80

102
500 500
450 630 42 450 560 42
0,74
0,74

400 400 100


Overall pressure increase ⌬pt1 [Pa] ➞

Overall pressure increase ⌬pt1 [Pa] ➞

99
355 560 37 355 500 37
315 315
96 93 280 97 450
280 90 500 33 94 91
33
250 250
224 450 39 224 400 39
* values rounded to standard figures

200 Power requirement at shaft: 200 Power requirement at shaft:


180 400 26 180 355 26
V [m3/h] · ⌬pt [Pa] 160 V [m3/h] · ⌬pt [Pa]
160 Pw [kW] = Pw [kW] =
140 ␩· 1000 · 3600 355 23 140 ␩· 1000 · 3600 315 23
125 125
112 112
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
100 000
112 000
125 000
140 000
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
100 000
112 000

Volume flow rate* Volume flow rate*


V [m3/h] V [m3/h]

Volume flow rate* Volume flow rate*


2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,8
3,55
4,5
5,6
7,1
9,0
11,2
14
18
22,4
28
35,5
45
56
71
90
112
140
180
224
280
355
450
560
2,8
3,55
4,5
5,6
7,1
9,0
11,2
14
18
22,4
28
35,5
45
56
71
90
112
140
180
224
280
355
450
560

pd [Pa] pd [Pa]
– 173 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Centrifugal Smoke Exhaust Fan, BV-REH series

for the extraction of smoke fumes


tested to EN 12101, Part 3 for 400 °C – 120 min.
with Technical University of Munich consultancy report
No. 98/1196-4
for installation outside the fire compartment.
– Casing of rugged, welded construction. From size 1120
upwards a horizontally split casing is standard, from
size 1250 upwards all casings are split in two planes.
– High-performance impeller of welded steel construction,
with backward curved blades, energy-optimized for
maximum efficiency.
– Rounded-edge inlet nozzle made of flow formed sheet
steel, aerodynamically matched to impeller
– Shaft with DIN 6885/1 keyway and key, Tectyl-coated.
Shaft impeller in two self-aligning ball (or roller) bearings
mounted in split cast-iron bearing pedestals,
Regreasable optionally with fan stationary or running.
– Impeller with Taperlock hub and shaft jointly balanced to
DIN ISO 1940 – G2.5 standard. Fitted on a rugged
bearing.
– Baseframe made of torsion-resistant U-section steel,
welded construction, to support the fan with bearing
pedestal and motor, including motor tensioning rails as
V-belt tensioning device.
– Outlet frame and inlet flange integrated into the casing
and inlet nozzle, respectively. Connecting dimensions in
accordance with DIN 24193 – Series 2 (Euro standard)
or DIN 24154, Series 3.
– Surface finished with powder coating or high-grade 1-
component synthetic coating.

BV-REH

Carryover
– 174 –
Unit price Total
Item
Qty. Description
No.
2 2

Specifications
Volume flow m3/h
Temperature 20°C
Total pressure increase Pa
Dynamic pressure Pa
Fan speed rpm
Efficiency %
Shaft power input requirement kW
Total acoustic pressure level Lw dB
Motor output kW
Motor speed rpm
Motor current rating A
Voltage V
Frequency Hz
Weight kg

Manufacturer: TLT-Turbo GmbH

Type: BV-REH

Accessory equipment:
• Standard three-phase motor, style B3 with terminal box,
protection class IP55 / ISO Cl. F, motor protection
• Flexible connector for 400°C (inlet/outlet)
• Flat flange (inlet)
• Angular frame (outlet)
• Spring-type antivibration mounts for 400°C
• Inspection hatch
• Condensate drain
• Lubricant line (bearings re-greasable in operation)
• V-belt drive (narrow type V-belt)
• V-belt guard
• RPM measuring orifice in V-belt guard
• Fan suitable for outdoor installation
• Thermal and acoustic insulation of fan casing

Note: Please observe our Installation, Operating and


Maintenance Instructions (available upon request).

Carryover
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
MAIN DIMENSIONS - WITHOUT INSULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
620°C – 90 MIN 175
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

i L

a1 e r2 b1
r1

ød1
H

q1 q2 v1 v2

(up to 6pt = 1800 Pa / as from 1800 - 2400 Pa subject to extra charge)

Casing orientations / Directions of rotation (viewed from drive side)

RD 90° RD 360° LG 90° LG 360°

Fan size Max. motor size a1 b1 ø d1 r2 r1 a1+e H H v +v v1 q2 q1 L i


Weight w/o
360° 90° 1 2 motor [kg]
180 90 183 146 183 172 175 216 242 220 576 113 550 150 510 173 36
90 594 520 40
200 205 164 205 190 190 240 260 235 122 580 150 182
100 624 550 43
90 613 530 50
224 229 183 229 210 205 270 285 255 132 580 150 192
112 643 560 53
100 645 650 550 55
250 256 205 256 230 220 300 310 275 143 175 203
132 725 700 630 60
112 710 650 585 60
280 288 229 288 268 264 336 350 315 155 180 215
132 785 700 660 70
112 736 650 620 80
315 322 256 322 284 266 380 380 330 168 190 228
132 841 750 725 110
112 782 650 650 100
355 361 288 361 318 292 430 425 370 188 230 244
160M 940 800 800 125
132S 892 810 730 130
400 404 322 404 360 330 480 480 430 211 290 261
BVRA

160M 1092 890 900 170


132S 981 850 800 155
450 453 361 453 396 354 540 520 450 230 320 281
160L 1131 950 950 205
132M 1004 880 800 180
500 507 404 507 450 405 600 590 520 252 330 312
180M 1184 970 980 220
160M 650 570 1143 282 950 920 250
560 569 453 569 500 450 670 400 327
180L 670 590 1250 272 1050 1110 320
160L 720 620 1237 309 1000 300
630 638 507 638 550 480 760 1050 430 354
200 740 640 1360 299 1250 360
180M 1260 1000 390
710 715 569 715 620 535 860 820 710 330 1150 500 385
225S 1515 1260 485
180L 1413 1120 460
800 801 638 801 690 590 960 930 795 369 1200 550 419
225M 1595 1300 513
200 1040 885 1585 408 1270 720
900 898 715 898 780 665 1080 1300 570 458
250M 1060 905 1725 413 1480 805
225S 1140 980 1802 451 1480 850
1000 1007 801 1007 870 740 1200 1300 610 520
280S 1160 1000 2080 456 1800 1020
250M 2008 1400 650 1650 1040
1120 1130 898 1130 984 836 1360 1300 1109 504 569
280M 2127 1450 700 1800 1400
250 1450 1240 2127 559 1450 1720 1300
1250 1267 1007 1267 1100 930 1520 700 624
315S 1470 1260 2402 564 1750 2010 1865
1400 315M 1421 1130 1421 1250 1040 1721 1650 1410 2450 630 2025 800 2000 685 2400

Dimensional changes reserved. Dimensions in mm


CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
MAIN DIMENSIONS - INCLUDING INSULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 176
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

i L

l r2 b1
a1
r1

ød1
H

q1 q2 v1 v2

(up to 6pt = 1800 Pa / as from 1800 - 2400 Pa subject to extra charge)

Casing orientations / Directions of rotation (viewed from drive side)

RD 90° RD 360° LG 90° LG 360°

Max. motor size a1 b1 ø d1 r2 r1 H H v +v v1 q2 q1 Weight w/o


Fan size l L i
360° 90° 1 2 motor [kg]
180 90 183 146 183 212 175 256 242 220 631 128 605 296 510 173 60
90 644 520 65
200 205 164 205 230 190 280 260 235 137 605 320 182
100 719 590 69
90 663 530 80
224 229 183 229 250 205 310 285 255 152 605 350 192
112 723 590 85
112 725 595 90
250 256 205 256 270 220 340 310 275 163 670 380 203
132 825 695 95
112 749 680 620 100
280 288 229 288 290 245 360 330 315 175 400 215
132 880 720 750 113
112 806 660 130
315 322 256 322 324 266 420 380 330 188 720 463 228
132M 890 755 135
112 838 670 160
355 361 288 361 358 292 470 425 370 204 720 510 244
160M 943 775 170
132S 942 760 205
400 404 322 404 360 330 520 480 430 221 840 570 261
160M 1080 890 218
132S 981 780 245
450 453 361 453 436 354 580 520 450 241 840 630 281
160L 1141 940 270
132M 1069 860 295
500 507 404 507 490 405 640 590 520 262 880 695 312
180M 1199 990 320
160M 650 570 1198 287 880 765 950 390
560 569 453 569 540 450 710 327
180L 670 590 1300 277 945 755 1050 430
160L 720 620 1252 1010 855 1000 470
630 638 507 638 590 480 800 319 354
200 740 640 1427 1020 845 1090 500
180M 820 710 1339 1035 945 1050 600
710 715 569 715 660 535 900 345 385
225S 840 730 1500 1050 950 1330 640
180L 1443 1120 720
800 801 638 801 730 590 1000 930 795 379 1100 1050 419
225M 1625 1430 750
180L 1520 1170 1045
1040 885 418
900 225S 898 715 898 820 665 1120 1650 1150 1170 1300 458 1065
250M 1060 905 1850 423 1500 1100
225S 1681 1330 1240
1160 1000 461 1170
1000 250M 1007 801 1007 910 740 1240 1861 1295 1510 520 1260
280S 1180 1020 2050 466 1430 1750 1280
250M 1986 1530 1545
1120 1130 898 1130 1026 836 1402 1340 1135 519 1340 1465 569
280M 2115 1780 1700
280S 2235 1736 2060
1250 1267 1007 1267 1142 930 1562 1480 1270 574 1625 1627 624
315S 2297 1895 2150
1400 315M 1421 1130 1421 1282 1040 1762 1670 1430 2525 640 1800 1832 2050 685 2550
Dimensional changes reserved. Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 177
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Outlet side angular frame Flexible connector


(matching frame) (rectangular)

B1/B3
B/B2
B1

zxL
zxL
B

ø d1
Ød

z1 x L L

B3

B2
Length of Flexible Connector: „L“
up to size 450 = 150 mm
as from size 500 = 200 mm

Size B B1 B2 B3 zxL z1 x L Ød Ød1

180 233 213 196 176 1 x 100 1 x 100 9,5 183


200 255 235 241 194 1 x 112 1 x 112 9,5 205
224 279 259 233 213 1 x 112 1 x 112 9,5 229
250 306 286 255 235 2 x 112 1 x 112 9,5 256
280 348 322 289 263 2 x 112 1 x 112 9,5 288
BVRA

315 382 356 316 290 2 x 125 1 x 125 9,5 322


355 421 395 348 322 2 x 125 2 x 125 9,5 361
400 464 438 382 356 3 x 125 2 x 125 9,5 404
450 513 487 421 395 3 x 125 2 x 125 9,5 453
500 567 541 464 438 3 x 125 3 x 125 9,5 507
560 639 605 523 489 3 x 160 2 x 160 11,5 569
630 708 674 577 543 3 x 160 2 x 160 11,5 638
710 785 751 639 605 4 x 160 3 x 160 11,5 715
800 871 837 708 674 3 x 200 3 x 200 11,5 801
900 968 934 785 751 4 x 200 3 x 200 11,5 898
1000 1077 1043 871 837 4 x 200 2 x 200 11,5 1007
1120 1210 1174 978 942 5 x 200 4 x 200 11,5 1130
1250 1347 1311 1087 1051 6 x 200 4 x 200 11,5 1267
1400 1501 1465 1210 1174 7 x 200 5 x 200 11,5 1421

Dimensional changes reserved. Dimensions in mm


CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 178
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Inlet side flange Flexible connector


(matching flange) (round)

z x ød

d1

ø d1

øD

ø d1
øk

k
L

Length of Flexible Connectors: „L“


up to size 450 = 150 mm
as from size 500 = 200 mm

Spring-type anti-vibration mounts


Size Ød1 Øk ØD z x Ød
Ø70 M10

180 183 213 233 6 x 9,5


200 205 235 255 6 x 9,5
50

224 229 259 279 6 x 9,5 Hight adjustment

250 256 286 306 6 x 9,5


280 288 322 348 8 x 9,5
appr. 85 under weight
94 w/o weight

315 322 356 382 8 x 9,5


Steel spring
355 361 395 421 8 x 9,5
400 404 438 464 12 x 9,5
450 453 487 513 12 x 9,5 Bottom plate
12

500 507 541 567 12 x 9,5


560 569 605 639 16 x 11,5
630 638 674 708 16 x 11,5
710 715 751 785 16 x 11,5
800 801 837 871 24 x 11,5
95
11

900 898 934 968 24 x 11,5


1000 1007 1043 1077 24 x 11,5
1120 1130 1174 1210 24 x 11,5
1250 1267 1311 1347 24 x 11,5 120
1400 1421 1485 1501 24 x 11,5 150

Dimensional changes reserved. Dimensions in mm


CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 179
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Outlet (for outdoor installation)

a1 +100 For frame


dimensions please
see page 175
°
45

a1 / b1
Birds mesh

100

Version of casing orientation RD/LG 90°

BVRA
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 180


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,0225 kgm2 BVRA 180 Number of blades: 8, moment of inertia: 0,0325 kgm2 BVRA 200
␩= ␩=
0

0
4000 4000
0,6

0,6

3
0,6

0,6
6

6
3550 3550
0,6

0,6
0

0
0,7

0,7
Fan speed [rpm]*

Fan speed [rpm]*


3155 3155
3

3
0,7

0,7
Tip speed [m/s]

Tip speed [m/s]


2800 2800
6

6
Please ask 0,7 Please ask

0,7
2500 2500
3

3
0,7

0,7
2240 2240
6

6
0,6

0,6
2000 2000
3

3
1800 1800
0,6

0,6
1600 6300 76,5 1600 5600 76,5
1400 1400
1250 5600 66,9 1250 5000 66,9
105 105
1120 1120
1000 5000 59,4 1000 4500 59,4
103 103
900 900
]

]
[dB

[dB
800 4500 52,7 800 4000 52,7
100 100
710 710
LW

LW
Total pressurre difference 䉭pt [Pa] 씮*

630 4000 47 Total pressurre difference 䉭pt [Pa] 씮* 630 3550 47


ent

ent
98 98
560 560
irem

irem
500 3550 42,4 500 3150 42,4
equ

equ
95 95
450 450
ut r

ut r
400 3150 37,6 400 2800 37,6
93 93
inp

inp
355 355
er

er
315 2800 33 315 2500 33
pow

pow
90 90
280 280
aft

aft
250 2500 29,4 250 2240 29,4
88 88
Sh

Sh
224 Power requirement 224 Power requirement
200 at shaft: 2240 26,4 200 at shaft: 2000 26,4
· · 䉭pt 85 · · 䉭pt
V 85
180 V 180
Pw = = Pw = =
160 ␩ · 1000 · 3600 2000 23,6 160 ␩ · 1000 · 3600 1800 23,6
83 83
355
400
450
500
560
630
710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800

450
500
560
630
710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,055 kgm2 BVRA 224 Number of blades: 8, moment of inertia: 0,075 kgm2 BVRA 250
␩= ␩=
0

4000 4000
0,6

0,6

3
0,6

0,6
6

3550 3550
0,6

0,6
0

0
0,7

0,7
Fan speed [rpm]*

3155 3155 Please ask


Fan speed [rpm]*
3

3
0,7

0,7
Tip speed [m/s]

Tip speed [m/s]


2800 2800
6

Please ask
0,7

0,7

2500 2500
3

3
0,7

0,7

2240 2240
6

6
0,6

0,6

2000 2000
3

1800 1800
0,6

0,6

1600 5000 76,5 1600 4500 76,5


1400 1400
1250 4500 66,9 1250 4000 66,9
108 108
1120 1120
1000 4000 59,4 1000 3550 59,4
105 105
900 900
]

]
[dB

[dB

800 3550 52,7 800 3150 52,7


103 103
710 710
W
Total pressurre difference 䉭pt [Pa] 씮*

W
Total pressurre difference 䉭pt [Pa] 씮*
L

630 3150 47 630 2800 47


ent

ent

100 100
irem

560 560
irem

500 2800 42,4 500 2500 42,4


equ

equ

98 98
450 450
r

2500 37,6 2240 37,6


put

400 400
put

95 95
in

in

355 355
er

er

315 2240 33 315 2000 33


pow

pow

93 93
280 280
aft

aft

250 2000 29,4 250 1800 29,4


90 90
Sh

Sh

224 Power requirement 224 Power requirement


200 at shaft: 1800 26,4 200 at shaft: 1600 26,4
· · 䉭pt
V 88 · · 䉭pt 88
180 Pw = = 180 V
Pw = =
160 ␩ · 1000 · 3600 1600 23,6 160 ␩ · 1000 · 3600 1400 23,6
85 85
560
630
710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500

710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600

Volume flow Volume flow


· [m3/h]* · [m3/h]*
V V

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pressure [Pa]* pressure [Pa]*


* Data rounded to standard figures
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 181


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,153 kgm2 BVRA 280 Number of blades: 8, moment of inertia: 0,25 kgm2 BVRA 315
␩= ␩=
0

0
4000 4000
0,6

0,6

3
0,6

0,6
6

6
3550 3550

0,6

0,6
0

0
0,7

0,7
Fan speed [rpm]*

Fan speed [rpm]*


3155 3155

3
0,7

0,7
Tip speed [m/s]

Tip speed [m/s]


2800 2800

6
0,7

0,7
2500 2500

3
0,7

0,7
2240 2240

6
0,6

0,6
2000 2000

3
1800 1800

0,6

0,6
1600 4000 76,5 1600 3550 76,5
1400 1400
1250 108 3550 66,9 1250 3150 66,9
108
1120 1120
1000 3150 59,4 1000 2800 59,4
105 105
900 900
]

]
[dB

[dB
800 2800 52,7 800 2500 52,7
103 103
710 710
LW

LW
Total pressurre difference 䉭pt [Pa] 씮*

Total pressurre difference 䉭pt [Pa] 씮*


630 2500 47 630 2240 47
ent

ent
100 100
560 560
irem

irem
500 2240 42,4 500 2000 42,4
equ

equ
98 98
450 450
ut r

ut r
400 2000 37,6 400 1800 37,6
95 95
inp

inp
355 355
er

er
315 1800 33 315 1600 33
pow

pow
93 93
280 280
aft

aft
250 1600 29,4 250 1400 29,4
90 90
Sh

Sh
224 Power requirement 224 Power requirement
200 at shaft: 1400 26,4 200 at shaft: 1250 26,4
V· · 䉭pt 88 V· · 䉭pt 88
180 Pw = = 180 Pw = =
160 ␩ · 1000 · 3600 1250 23,6 160 ␩ · 1000 · 3600 1120 23,6
85 85
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100

1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,38 kgm2 BVRA 355 Number of blades: 8, moment of inertia: 0,618 kgm2 BVRA 400
␩= ␩=
0

4000 4000
0,6

0,6

3
0,6

0,6
6

3550 3550
0,6

0,6
0

0
0,7

0,7

3155 3155
Fan speed [rpm]*
Fan speed [rpm]*
3

3
0,7

0,7

Tip speed [m/s]


Tip speed [m/s]

2800 2800
6
6

0,7
0,7

2500 2500
3

3
0,7

0,7

2240 2240
6

6
0,6

0,6

2000 2000
3

1800 1800
0,6

0,6

1600 3150 76,5 1600 2800 76,5


1400 1400
1250 2800 66,9 1250 2500 66,9
110 110
1120 1120
BVRA

1000 2500 59,4 1000 2240 59,4


108 108
900 900
]
]

[dB
[dB

800 2240 52,7 800 2000 52,7


105 105
710 710
LW
LW

Total pressurre difference 䉭pt [Pa] 씮*


Total pressurre difference 䉭pt [Pa] 씮*

630 2000 47 630 1800 47


ent
ent

103 103
560 560
irem
rem

500 1800 42,4 500 1600 42,4


i

equ
equ

100 100
450 450
ut r
ut r

400 1600 37,6 400 1400 37,6


98 98
inp
inp

355 355
er
er

315 1400 33 315 1250 33


pow
ow

95 95
280 280
p

aft
aft

250 1250 29,4 250 1120 29,4


93 93
Sh
Sh

224 Power requirement 224 Power requirement


200 at shaft: 1120 26,4 200 at shaft: 1000 26,4
90
180 V· · 䉭pt 180 V· · 䉭pt 90
Pw = = Pw = =
160 ␩ · 1000 · 3600 1000 23,6 160 ␩ · 1000 · 3600 900 23,6
88 88
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200

1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000

Volume flow Volume flow


V· [m3/h]* V· [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pressure [Pa]* pressure [Pa]*


* Data rounded to standard figures
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 182


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,933 kgm2 BVRA 450 Number of blades: 8, moment of inertia: 1,5 kgm2 BVRA 500
␩=
0

0
4000 4000 ␩=
0,6

0,6

3
0,6

0,6
6

6
3550 3550
0,6

0,6
0

0
0,7

0,7
Fan speed [rpm]*

Fan speed [rpm]*


3155 3155
3

3
0,7

0,7
Tip speed [m/s]

Tip speed [m/s]


2800 2800

6
6

0,7
0,7
2500 2500
3

3
0,7

0,7
2240 2240
6

6
0,6

0,6
2000 2000
3

3
1800 1800
0,6

0,6
1600 2500 76,5 1600 2240 76,5
1400 1400
1250 2240 66,9 1250 2000 66,9
110 113
1120 1120
1000 2000 59,4 1000 1800 59,4
108 110
900 900
]

]
[dB

[dB
800 1800 52,7 800 1600 52,7
105 108
710 710
LW

LW
Total pressurre difference 䉭pt [Pa] 씮*

630 1600 47 Total pressurre difference 䉭pt [Pa] 씮* 630 1400 47


ent

ent
103 105
560 560
irem

irem
500 1400 42,4 500 1250 42,4
equ

equ
100 103
450 450
ut r

ut r
400 1250 37,6 400 1120 37,6
98 100
inp

inp
355 355
er

er
315 1120 33 315 1000 33
pow

pow
95 98
280 280
aft

aft
250 1000 29,4 250 900 29,4
93 95
Sh

Sh
224 Power requirement 224 Power requirement
200 at shaft: 900 26,4 200 at shaft: 800 26,4
· · 䉭pt
V 90 · · 䉭pt 93
V
180 Pw = = 180 Pw = =
160 ␩ · 1000 · 3600 800 23,6 160 ␩ · 1000 · 3600 710 23,6
88 90
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000

2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 2,225 kgm2 BVRA 560 Number of blades: 8, moment of inertia: 3,5 kgm2 BVRA 630
␩= ␩=
0

4000 4000
0,6

0,6

3
0,6

0,6
6

3550 3550
0,6

0,6
0

0
0,7

0,7

3155 3155
Fan speed [rpm]*
Fan speed [rpm]*
3

3
0,7

0,7

Tip speed [m/s]


Tip speed [m/s]

2800 2800
6
6

0,7
0,7

2500 2500
3

3
0,7

0,7

2240 2240
6

6
0,6

0,6

2000 2000
3

1800 1800
0,6

0,6

1600 2000 76,5 1600 1800 76,5


1400 1400
1250 1800 66,9 1250 1600 66,9
113 113
1120 1120
1000 1600 59,4 1000 1400 59,4
110 110
900 900
]
]

[dB
[dB

800 1400 52,7 800 1250 52,7


108 108
710 710
W
W

Total pressurre difference 䉭pt [Pa] 씮*


Total pressurre difference 䉭pt [Pa] 씮*

L
L

630 1250 47 630 1120 47


ent
ent

105 105
560 560
irem
irem

500 1120 42,4 500 1000 42,4


equ
equ

103 103
450 450
r
r

400 1000 37,6 400 900 37,6


put
put

100 100
in
in

355 355
er
er

315 900 33 315 800 33


pow
pow

98 98
280 280
aft
aft

250 800 29,4 250 710 29,4


95 95
Sh
Sh

224 Power requirement 224 Power requirement


200 at shaft: 710 26,4 200 at shaft: 630 26,4
· · 䉭pt 93 · · 䉭pt 93
180 V 180 V
Pw = = Pw = =
160 ␩ · 1000 · 3600 630 23,6 160 ␩ · 1000 · 3600 560 23,6
90 90
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000

4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500

Volume flow Volume flow


· [m3/h]* · [m3
V V /h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pressure [Pa]* pressure [Pa]*


* Data rounded to standard figures
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 183


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 7,0 kgm2 BVRA 710 Number of blades: 8, moment of inertia: 11,5 kgm2 BVRA 800
␩= ␩=
0

0
4000 4000
0,6

0,6

3
0,6

0,6
6

6
3550 3550

0,6

0,6
0

0
0,7

0,7
Fan speed [rpm]*

Fan speed [rpm]*


3155 3155

3
0,7

0,7
Tip speed [m/s]

Tip speed [m/s]


2800 2800

6
6

0,7
0,7
2500 2500

3
0,7

0,7
2240 2240

6
0,6

0,6
2000 2000

3
1800 1800

0,6

0,6
1600 1600 76,5 1600 1400 76,5
1400 1400
1250 1400 66,9 1250 1250 66,9
115 115
1120 1120
1000 1250 59,4 1000 1120 59,4
113 113
900 900
]

]
[dB

[dB
800 1120 52,7 800 1000 52,7
110 110
710 710
LW

LW
Total pressurre difference 䉭pt [Pa] 씮*

Total pressurre difference 䉭pt [Pa] 씮*


630 1000 47 630 900 47
ent

ent
108 108
560 560
irem

irem
500 900 42,4 500 800 42,4
equ

equ
105 105
450 450
ut r

ut r
400 800 37,6 400 710 37,6
103 103
inp

inp
355 355
er

er
315 710 33 315 630 33
pow

pow
100 100
280 280
aft

aft
250 630 29,4 250 560 29,4
98 98
Sh

Sh
224 Power requirement 224 Power requirement
200 at shaft: 560 26,4 200 at shaft: 500 26,4
V· · 䉭pt 95 V· · 䉭pt 95
180 Pw = = 180 Pw = =
160 ␩ · 1000 · 3600 500 23,6 160 ␩ · 1000 · 3600 450 23,6
93 93
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000

7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 18 kgm2 BVRA 900 Number of blades: 8, moment of inertia: 32 kgm2 BVRA 1000
␩= ␩=
0

4000 4000
0,6

0,6

3
0,6

0,6
6

3550 3550
0,6

0,6
0

0
0,7

0,7

3155 3155
Fan speed [rpm]*
Fan speed [rpm]*
3

3
0,7

0,7

Tip speed [m/s]


Tip speed [m/s]

2800 2800
6
6

0,7
0,7

2500 2500
3

3
0,7

0,7

2240 2240
6

6
0,6

0,6

2000 2000
3

1800 1800
0,6

0,6

1600 1250 76,5 1600 1120 76,5


1400 1400
1250 1120 66,9 1250 1000 66,9
115 118
1120 1120
BVRA

1000 1000 59,4 1000 900 59,4


113 115
900 900
]
]

[dB
[dB

800 900 52,7 800 800 52,7


110 113
710 710
W
LW

Total pressurre difference 䉭pt [Pa] 씮*


Total pressurre difference 䉭pt [Pa] 씮*

630 800 47 630 710 47


ent
ent

108 110
560 560
irem
irem

500 710 42,4 500 630 42,4


equ
equ

105 108
450 450
r
ut r

400 630 37,6 400 560 37,6


put

103 105
inp

in

355 355
er
er

315 560 33 315 500 33


pow
pow

100 103
280 280
aft
aft

250 500 29,4 250 450 29,4


98 100
Sh
Sh

224 Power requirement 224 Power requirement


200 at shaft: 450 26,4 200 at shaft: 400 26,4
180 V· · 䉭pt 95
180 V· · 䉭pt
98
Pw = = Pw = =
160 ␩ · 1000 · 3600 400 23,6 160 ␩ · 1000 · 3600 355 23,6
93 95
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000

11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000

Volume flow Volume flow


V· [m3/h]* V· [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pressure [Pa]* pressure [Pa]*


* Data rounded to standard figures
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 620°C – 90 MIN 184


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 57,5 kgm2 BVRA 1120 Number of blades: 8, moment of inertia: 94 kgm2 BVRA 1250
␩=
0

0
4000 4000 ␩=
0,6

0,6

3
0,6

0,6
6

6
3550 3550
0,6

0,6
0

0
0,7

0,7
Fan speed [rpm]*

Fan speed [rpm]*


3155 3155
3

3
0,7

0,7
Tip speed [m/s]

Tip speed [m/s]


2800 2800

6
6

0,7
0,7
2500 2500
3

3
0,7

0,7
2240 2240
6

6
0,6

0,6
2000 2000
3

3
1800 1800
0,6

0,6
1600 1000 76,5 1600 900 76,5
1400 1400
1250 900 66,9 1250 800 66,9
118 118
1120 1120
1000 800 59,4 1000 710 59,4
115 115
900 900
]

]
[dB

[dB
800 710 52,7 800 630 52,7
113 113
710 710
LW

LW
Total pressurre difference 䉭pt [Pa] 씮*

630 630 47 Total pressurre difference 䉭pt [Pa] 씮*


630 560 47
ent

ent
110 110
560 560
irem

irem
500 560 42,4 500 500 42,4
equ

equ
108 108
450 450
ut r

ut r
400 500 37,6 400 450 37,6
105 105
inp

inp
355 355
er

er
315 450 33 315 400 33
pow

pow
103 103
280 280
aft

aft
250 400 29,4 250 355 29,4
100 100
Sh

Sh
224 Power requirement 224 Power requirement
200 at shaft: 355 26,4 200 at shaft: 315 26,4
· · 䉭pt
V 98 · · 䉭pt 98
180 180 V
Pw = = Pw = =
160 ␩ · 1000 · 3600 315 23,6 160 ␩ · 1000 · 3600 280 23,6
95 95
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000
100000
112000
125000
140000
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000
100000
112000

Volume flow Volume flow


· ·
V [m3/h]* V [m3/h]*

Flow velocity Flow velocity


4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*

Temperature: 20°C, density: 1,2 kg/m3


Number of blades: 8, moment of inertia: 158 kgm2 BVRA 1400
0

4000 ␩=
0,6

3
0,6

3550
0,6

0
0,7

3155
Fan speed [rpm]*
3
0,7

Tip speed [m/s]

2800
6
0,7

2500
3
0,7

2240
6
0,6

2000
3

1800
0,6

1600 800 76,5


1400
1250 710 66,9
120
1120
1000 630 59,4
118
900
]
[dB

800 560 52,7


115
710
W
Total pressurre difference 䉭pt [Pa] 씮*

630 500 47
ent

113
560
irem

500 450 42,4


equ

110
450
r

400 400 37,6


put

108
in

355
er

315 355 33
pow

105
280
aft

250 315 29,4


103
Sh

224 Power requirement


200 at shaft: 280 26,4
· · 䉭pt 100
180 V
Pw = =
160 ␩ · 1000 · 3600 250 23,6
98
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000
100000
112000
125000
140000
160000
180000

Volume flow
· [m3/h]*
V

Flow velocity
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5

c1 = c2 [m/s]*
Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630

pressure [Pa]*
* Data rounded to standard figures
– 185 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Centrifugal Smoke Exhaust Fan, BVRA series

for the extraction of smoke fumes of


max. 620°C – 90 minutes.
tested to DIN 18232, Part 6 (Technical University of Mu-
nich)
with general building supervision approval Z-78.1-16
For installation outside the fire zone.
Motor cooled with ambient air not exceeding 40°C.
Consisting of
Spiral casing made of welded sheet steel, with
appropriate stiffening.
Outlet with DIN 24158, Series 3 flanges.
Inlet with DIN 24154, Series 3, flanges.
Centrifugal impeller, single inlet type,
of welded sheet steel construction,
dynamically balanced as per DIN ISO 1940
quality grade G 6,3.
Fan shaft with cooling disc and shaft seal, supported in
pedestal bearings.
V-belt drive complete with two pulleys, V-belt and
guard.
Casing coated with temperature-resistant aluminium
paint (for indoor installation).
Specifications:
Volume flow m3/h
Temperature (design) 20°C
Temperature (max./withstand time) °C/min
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Efficiency %
Shaft power input requirement kW
Total acoustic power level Lw dB
Weight of fan with accessories kg BVRA

Manufacturer: TLT-Turbo GmbH

Type: BVRA

Carryover
– 186 –
Unit price Total
Item
Qty. Description
No.
2 2

Accessory equipment:
• Horizontally split casing
• Flexible connectors*
(temperature-resistant)
- inlet side
- outlet side
• Set of matching frames*
• Condensate drain
• Inspection hatch in the fan housing
• Set of spring-type antivibration mounts*
• Outlet for outdoor installation
• Weather protection for motor and V-belt drive
• Special coating for outdoor installation
• Galvanised fan casing
• Thermal insulation for fan casing
• Three-phase motor in accordance with IEC standard
style B3, protection class IP 55, insulation class B
single-speed unit
or with Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz

Note: Please observe our Installation, Operating and


Maintenance Instructions (available upon request).

* Loosely supplied
Carryover
SMOKE EXHAUST PLUG FANS
CENTRIFUGAL TYPE
BV-ERV SERIES FOR 300°C – 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany OVERVIEW 187
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Technical Description In addition, these fans are calibrated as


These units are rated for 300°C – 120 volumetric flow measuring devices.
min. operation and tested to DIN - The impeller components and inlet
12101 / Part 3 standard specificati- nozzle are made by a flow forming /
ons. metal spinning process for high ma-
- 14 sizes from 250 to 1120 nufacturing precision.
- The base structure consisting of the
- Max. volume flow: 56,000 m3/h
mounting plate, motor bracket and
- Available static pressure differential: baseframe is of torsion-resistant
1600 Pa welded and screwed construction.
- Impeller aerodynamically optimized - Following pre-treatment, the com-
for free outlet configuration, of wel- ponents receive a polyester powder
ded steel sheet construction, dyna- coating which is then stoved at
mically balanced in compliance with 215°C for maximum durability. Si-
DIN ISO 1940 / Grade G 2,5, com- zes exceeding 1120 mm in diameter Units with frequency converter con-
plete with screw-in hub, for counter- are coated with a two-layer paint sy- trol are equipped with a PTC thermi-
clockwise rotation (viewed from dri- stem. stor-based motor protection system
ve side). (approved for ventilation mode only,
- The heat-resistant special motor
- Flow-formed inlet nozzle, made of (protection class IP 54, style B3) i.e., in the case of a fire the fan must
sheet steel, aerodynamically mat- operates in the exhaust gas flow. be switched to mains operation with
ched to the impeller. the PTC thermistors shunted).
Accessory equipment:
E ØA
- Flexible inlet connector
F G b
- Flat-type flange (inlet)
- Inlet wire guard
F
- Set of antivibration mounts
i.d.

- Inlet nozzle with ring line for pres-


Øk
J

sure measurements
- Three-phase motor, size ...
H

For characteristic curves, model


zxØd tender call documents and additio-
nal technical data please refer to
K our complete „Centrifugal Plug-in
L C
Fans“ catalogue (ER 23/1.2).

ca. Weight
Gewicht
Bau- Number of holes
Lochzahl
Size ØA H C i.d.
Ødi.L. ca.~ E F G b ~JJ
ca. K L Øk ohne Motor
(approx.)
größe z x Ød
BV-ERV

without
[kg]motor
250 306 250 290 256 617 258 179 180 403 240 420 286 6 7 25
280 348 250 290 288 639 260 202 180 426 240 420 322 8 10 30
Series 3 / DIN 24 154

315 386 285 350 322 710 310 220 180 478 285 500 356 8 10 38
355 425 320 350 361 733 310 249 180 533 285 500 395 8 10 45
400 468 360 435 404 860 410 270 180 594 385 675 438 12 10 65
450 517 400 435 453 895 410 308 180 650 385 675 487 12 10 80
500 571 450 435 507 940 415 345 180 736 385 705 541 12 10 95
560 643 530 480 569 998 430 389 180 852 405 730 605 16 12 115
630 712 570 480 638 1046 430 436 180 926 405 730 674 16 12 135
Series 2 / DIN 24 154

710 814 640 480 714 1186 510 496 180 1047 475 900 775 16 14 170
800 904 715 600 804 1240 510 550 180 1167 475 1000 861 24 14 250
900 1004 800 650 904 1478 680 618 180 1302 645 1150 958 24 14 340
1000 1105 900 650 1005 1545 680 685 180 1453 645 1115 1067 24 14 430
1120 1125 1000 780 1005 1679 740 734 205 1553 710 1350 1067 27 14 500
SMOKE EXHAUST FANS
SMOKE DETECTION SWITCHES FOR
MECHANICAL SMOKE EXTRACTION SYSTEMS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 189
Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Safety through certified to Building Rules List "B", Part 2, in The mechanical smoke extraction sy-
products conjunction with the relevant smoke stem is activated by pushbutton or
detectors. Compliance with the codes automatically by means of smoke
The purpose of a smoke and heat ex- is demonstrated via certification tests switches. A controller sends out con-
haust system is to protect human performed by independent testing in- trol signals to energize the powered
beings from the risks and hazard si- stitutes. smoke exhaust installation and to mo-
tuations typically encountered in a fi- ve the fire protection and smoke ex-
re. Smoke exhaust fans are tested ac- haust dampers into their safety positi-
cording to the European test standard on. An effective interaction between
This target can only be achieved via a EN 12101-3.
reliable mechanical smoke extraction the individual components ensures a
system. rapid detection and alarm response
Optimum component so that smoke can be extracted quick-
To provide optimum protection, the interaction ly from the fire zone.
individual components of a mechani-
cal smoke extraction installation must A powered smoke and heat exhaust
be optimally matched. system comprises at least the follo-
wing components:
Smoke exhaust fans and fire protec-
tion dampers therefore have to be ap- • Triggering device
proved by the German Institute of • Controller
Building Technology (DIBt) according • Smoke extraction system

Example of a mechanical smoke extraction system

Roof-mounting smoke exhaust fan

Rauchschalter

Smoke switch Smoke switch

Smoke-free layer

Pushbutton switch
Building services
management
system

Air supply Controller


– 190 –
Unit price Total
Item
Qty. Description
No.
2 2

1.0 Smoke switches for mechanical smoke extraction


systems
Specification
Title 1 – Prerequisites
1. Function and application
The analyzing and triggering device of a mechanical
smoke extraction system responds to the first signs of a
fire. It actuates downstream protection systems
immediately and automatically.
This device is specifically used as an analyzing and
triggering unit for mechanical smoke extraction systems.
It immediately energizes the smoke exhaust fan and the
smoke exhaust dampers, if any, in accordance with the
rules of the German Institute of Building Technology
(DIBt)
2. Approval
Smoke control switchgear must be approved by the
Berlin-based DIBt Institute. All system components must
have been jointly tested and approved and documented
in a written DIBt certificate.
Only devices confirmed in this approval must be used in
combination.
3. Quality monitoring
In addition to the manufacturer's own quality assurance,
the approval certificate requires "quality monitoring" or
"external monitoring" for mechanical smoke extraction
systems to be conducted by the Association of German
Property Insurers (VdS) in Cologne.
Any monitoring agreement to that effect, concluded
between the manufacturer and the VdS association, must
be DIBt-approved. The results of the manufacturer's in-
house quality assurance efforts must be submitted to DIBt
upon request.
In addition to these requirements, an approval sign must
be fitted in the direct vicinity of the analyzing and
triggering device. The individual units must carry the
uniform certification label. Our smoke control switchgear
systems are subject to VdS quality monitoring.

Carryover
– 191 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

1.0 (cont’d) Excerpts from the valid approval certificate:


4. Smoke switch installation
The arrangement and number of smoke
switches/detectors must conform to DIN VDE 0833-2
specifications. A reliable detection of smoke must be
ensured.
5. Electrical wiring
Electrical wiring must be designed separately and with
appropriate mechanical protection so that its operability
will be ensured for at least 30 minutes, as set forth in DIN
4102-12. It shall be routed using appropriate protection
techniques.
6. Acceptance
The analyzing and triggering device shall be examined for
proper installation and functioning, and specifically for
appropriate component interaction, immediately before
the smoke exhaust system is first taken into operation.
The acceptance tests shall be documented by the
operator of the smoke exhaust system, who shall also file
the related documentation. Upon successful completion
of the acceptance test, the relevant authority shall install
an acceptance sign in the immediate vicinity of the
analyzing and triggering device, such sign to be supplied
by the manufacturer.
7. Upkeep
The analyzing and triggering device shall be kept
operative and in a good state of repair by the operator of
the smoke exhaust system at all times.
8. Maintenance
The analyzing and triggering device shall be
maintenanced monthly and inspected for its proper
functional condition and operability in accordance with the
manufacturer's instruction. In particular, all connected
smoke detectors shall be tested by simulation (application
of test gas). Rauchschalter
Maintenance activities and operability tests shall be
documented by the operator of the smoke exhaust
system, who shall duly file all related documentation.

Carryover
– 192 –
Unit price Total
Item
Qty. Description
No.
2 2

1.1 Controllers
Designed to control the mechanical smoke extraction
system and provide a visual indication of operating status
and alarms. Any transducing sensors connected to the
system remain activated throughout the smoke exhaust
cycle. Multiple controllers may be combined for the
purpose of managing a single powered smoke exhaust
system and actuating the associated smoke exhaust
dampers.
Approved by the German Institute of Building Technology
(DIBt) as an analyzing and triggering device for smoke
exhaust dampers and smoke exhaust fans.
- Smoke switch connection
- Connection of air supply dampers
- Connection of the smoke exhaust damper
- Connection for actuating the smoke exhaust fan
- Connection of a momentary-contact pushbutton switch
for manual triggering
- Connection of a momentary-contact pushbutton switch
for manual control of the smoke exhaust system
- Connection for audible alarm devices
- Connection for visual alarm devices
- Floating-contact alarm relay (changeover contact type,
30 V / 1A)
- Installation space for 2 additional alarm relays with two
changeover contacts each (250 VAC / 5 A)
Product covered by Building Supervision Authority
approval.
Mains voltage 230 VAC
Output voltage 24 VDC
Rated current max. 0,8 A
Protection class IP 20
DIBt-approval No.
Manufacturer
Type
1.2 Optical smoke switches
Designed as a triggering device for indoor (room)
monitoring, equipped with a smoke and heat sensor for
controlling mechanical smoke extraction systems. Units in
compliance with the DIBt code of practice, fitted in a
plastic housing with bayonet cap and featuring the
following:
Smoke detection by the stray light principle
Status indication via integrated LEDs, as follows:
LED green in operation
LED green/yellow (flashing slowly) slightly soiled
LED green/yellow (flashing rapidly) highly soiled
LED yellow measuring cell failure
LED red alarm

Carryover
– 193 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

Long-term alarm threshold correction


Temperature sensing via semiconductor-based sensor,
triggering when the temperature threshold (approx. 70°C)
is exceeded.
No use of radioactive substances
Built-in relay (floating contact)
Communication output port for smoke switch status
indication or status polling via PC and/or modem
Available in white, red, brown, yellow and black.
Product covered by Building Supervision Authority
approval.
Operating voltage: 14 VDC
protection class: IP 42
VdS test report No.:
DIBt approval No.
Manufacturer:
Type:
1.3 Base
For smoke switches, designed for apparent installation in
dry indoor locations, in the form of a plastic housing with
built-in screw terminals.
Product covered by Building Supervision Authority
approval.
Standard housing colour: white
Special colours: red, brown, yellow, black
Manufacturer:
Type:
1.4 Base
For smoke switches, designed for apparent installation in
damp indoor locations, in the form of a plastic housing
with
Built-in screw terminals
Cable gland (PG 7) with rubber O-ring seal
between detector and base.
Product covered by Building Supervision Authority
approval. Rauchschalter
Standard housing colour: white
Special colours: red, brown, yellow, black
Manufacturer:
Type:
1.5 Base
For smoke switches, designed for concealed installation
in suspended ceilings in dry indoor locations, in the form
of a plastic housing with a white trim ring.
Built-in screw terminals
Product covered by Building Supervision Authority
approval.
Standard housing colour: white
Special colours: red, brown, yellow, black
Manufacturer:
Type: Carryover
– 194 –
Unit price Total
Item
Qty. Description
No.
2 2

1.6 Smoke switch status indicating unit


Provides a collective status indication for all connected
smoke switches.
Control and communication signalling via RS bus
Bus line continuity monitoring
Monitoring of connected smoke switches for unauthorized
replacement.
Inevitable functional test during commissioning.
(Smoke switches must be triggered by simulation of the
smoke detection parameter).
Status indication via integrated LEDs, as follows:
LED 1 green in operation
LED 2 yellow slightly soiled
LED 3 yellow highly soiled
LED 4 yellow measuring cell failure
LED 4 flashing yellow RS bus error, unknown
smoke switch
LED 5 red alarm
Built-in relay (floating-contact, 30 VDC/1 A) for each
status message
(LED), e.g., for connection to a building services
management system.
For apparent installation. Colour: white.
Product covered by Building Supervision Authority
approval.
Operating voltage 18 ... 28 VDC
Protection class: IP 20
Manufacturer:
Type:
Qty:
1.7 Smoke switch status indicating unit
Providing a collective status indication for all connected
smoke switches.
Control and communication signaling via RS bus
Bus line continuity monitoring
Monitoring of connected smoke switches for unauthorized
replacement.
Inevitable functional test during commissioning.
(Smoke switches must be triggered by simulation of the
smoke detection parameter).
Status indication via integrated LEDs, as follows:
LED 1 green in operation
LED 2 yellow slightly soiled
LED 3 yellow highly soiled
LED 4 yellow measuring cell failure
LED 4 flashing yellow RS bus error, unknown
smoke switch
LED 5 red alarm
Built-in relay (floating-contact, 30 VDC /1 A) for each
status message
(LED), e.g., for connection to a building services
management system.
For concealed installation. Colour: white.
Product covered by Building Supervision Authority
approval.
Operating voltage 18 ... 28 VDC
Protection class: IP 20 Carryover
Manufacturer:
Type:
Qty:
– 195 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2

1.8 Smoke switch interface

For polling status messages from the connected smoke


switches by means of PC or modem and PC, via RS bus
communication.

Information polled:
Type of smoke switch
Smoke switch manufacturing No. (PID)
Smoke switch ID No. within the system (allocated by the
system during first commissioning)
Operation
Slightly soiled
Highly soiled
Error / measuring cell failure
Unknown smoke switch within the system
Alarm
Temperature
RS 232 interface for PC or modem connection
PC log file documenting first commissioning data
PC log file documenting status polling
PC log file documenting prescribed maintenance
procedures including info on whether all connected
smoke switches were tested.
For apparent installation, colour: white

Product covered by Building Supervision Authority


approval.

Operating voltage 18 ... 28 VDC


Protection class: IP 20
Manufacturer:
Type:
Qty:

1.9 Modem

For remote-polling the status of smoke switches in a Rauchschalter


smoke exhaust system.
Wall-mounting / desktop type
Colour: anthracite
Including power supply unit and mains cable
Similar or equivalent to Hekatron type MOD 142A.
Supply and installation.

Product covered by Building Supervision Authority


approval.

Manufacturer:
Type:
Qty:

Carryover
– 196 –
Unit price Total
Item
Qty. Description
No.
2 2

1.10 Momentary-contact pushbutton unit


For indoor use, type G, painted yellow, for apparent
installation in dry indoor locations, providing manual
control of the smoke exhaust system.
Features:
Flat-type plastic housing
Replaceable glass pane
2 momentary-contact switches with monitoring LED
Standard colour: yellow (RAL 1003)
Special colours: red, grey, blue
Protection class IP 20
Weight: 0.167 kg
Manufacturer:
Type:
1.11 Acoustic alarm device
With plastic housing for apparent installation, VdS-
approved.
Features:
Programmable with two alternating tones or one
continuous tone, signal tone in accordance with DIN
33404, Part 3.
Acoustic level: 105 dB(a) at 1 m distance
Operating voltage: 24 V d.c
Current consumption: max. 18 mA
Protection class: IP 54
VdS approval No.
Manufacturer:
Type:
1.12 Acceptance set
Comprising:
Acceptance record form
Maintenance record form
DIBt approval plate
DIBt approval certificate
Manufacturer:
Type:
Qty:
1.13 Smoke detector tester
For on-site testing of smoke detectors and smoke
switches outside ventilation ducting, comprising
Test head 918
Aerosol container 918/5
Holding rod, 1.7 m long
Telescope-type holding rod, max. length 3.2 m, 918/1
Telescope-type holding rod, max. length 3.2 m, 918/2
Product covered by Building Supervision Authority
approval.
Manufacturer:
Type:

Carryover
SMOKE EXHAUST FANS
APPLICATION EXAMPLES/REFERENCES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Centrifugal smoke exhaust fan BV-REH 560 Axial smoke exhaust fan BVAXN 12/56/900 for 300°C - 120 Min. casing insulated
for 400°C - 120 Min. casing insulated (Alsenblöcke, Berlin)
(Alsenblöcke, Berlin)

Centrifugal smoke exhaust fan BVRA 710 Axial smoke exhaust fan BVAX 12/56/800
for 620°C - 90 Min. (Dorotheen-Blöcke, Berlin) for 300°C - 120 Min. with self-activating shutoff dampers (Dorotheen-Blöcke, Berlin)

Roof-mounting smoke exhaust fans BVD 630/30-6 Axial smoke exhaust fan BVAXN 8/56/1120
for 620°C - 120 Min. with stubs for admixture of ambient air for 600°C - 120 Min. with self-activating shutoff dampers and outlet duct
(Berlin State Archives) with wire guard (Oyten refrigerating facility)
SMOKE EXHAUST FANS
APPLICATION EXAMPLES / REFERENCES

Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 201


Phone: +49.6621.950-0 · Fax: +49.6621.950-100

Roof-mounting smoke exhaust fans BVD and axial smoke-exhaust fans BVAXN Roof-mounting smoke exhaust fans BVD
(Leipzig, Paunsdorf shopping mall) Check-in terminal, Franz-Josef Strauss
Airport, Munich

Roof-mounting smoke exhaust fans BVD 710 for 620°C–120 min. Wall-mounting smoke exhaust fans BVW-R
Cologne Arena Freight handling complex, Franz-Josef
Strauss Airport, Munich

Axial smoke exhaust fans for 400°C–120 min. with outlet diffusers Wall-mounting smoke exhaust fans BVW-A
(Düsseldorf Airport, Terminal C) Furniture store Unger, Wolfratshausen
TLT-Turbo GmbH
Am Weinberg 68
D-36251 Bad Hersfeld/Germany

Phone: + 49.6621.950-0
Fax: + 49.6621.950-100

E-mail: serie@tlt.de
Website: www.tlt.de

© 2005 - TLT-Turbo GmbH · 13th edition 02.04/1,25/G · Subject to errors and modifications.