Beruflich Dokumente
Kultur Dokumente
Aktionsgemeinschaft Entrauchung
TLT-Turbo GmbH
TLT-TURBO GMBH
STANDARD FAN PRODUCTION PLANT AT
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
BAD HERSFELD 002
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Our Bad Hersfeld facility has a histo- blished in June 1995, now integrating
ry going back to 1874, when Benno Babcock-BSH’s Air and Thermal En-
Schilde and August Büttner founded gineering division.
their factories here.
The “TLT-Turbo GmbH”, newly esta-
The “exhausters” traditionally made blished in March 2003 as a company
of cast iron could be built much lighter in their own rights, belongs to AG
and cheaper through the use of steel Kühnle, Kopp & Kausch, Frankenthal.
sheet.
TLT now is one of the world’s leading
At Büttner the focus was initially on fan manufacturers and our compe-
blowers for tubular boilers and dryers, tence is expressed in mature and
then shifted to heavy-duty industrial very economical products. Our two
fans as required specifically in power R&D centres at Zweibrücken and Bad
plant de-dusting applications. Schil- Hersfeld guarantee a continuing pro-
de, meanwhile, stepped up its rese- cess of always adapting all TLT pro-
arch and development of light-duty ducts to the latest demands of the
ventilating fans and medium-duty in- market.
dustrial blowers. Numerous patents
and registered designs testify to a
steady flow of engineering breakth-
roughs. With the erection of its series
production facility at Bad Hersfeld,
dedicated mainly to the cost-effective
production of roof fans, the Babcock-
BSH Group gained a leading market
position both in Germany and abroad.
The Turbo-Lufttechnik GmbH (TLT) –
Bad Hersfeld site - was newly esta-
All technical details in this catalogue are subject to modification without prior notice.
SMOKE EXHAUST FANS
FOR ROOF- OR WALL-INSTALLATION OR AS
CENTRAL VENTILATION FANS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany INDEX 003
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Centrifugal Plug-In Smoke Exhaust Fans BV-ERV Product Range - Overview and
300°C – 120 min. Main Dimensions 187
3.0 Basic considerations 4.0 History of TLT smoke technik GmbH of Bad Hersfeld sup-
exhaust fans plies a complete range of smoke and
Some recent fires have reminded fume exhaust fans for virtually any
us of the vast potential for destruc- In the early '70s, a fire in a PVC film application. Needless to say, each
tion, injury and loss of life that fire manufacturing shop devastated the model is fully tested and certified ac-
may have. Its perils lie in the blaze production facilities of Kalle AG in cording to the latest European stan-
that forms the core of the disaster Wiesbaden, a leading manufacturer dards and regulations. And it all be-
and in its products such as smoke of packaging film. Presumably, an gan with that "small fire” at Kalle AG
and heat, both of which are at their overheated bearing had ignited a in Wiesbaden.
most hazardous form in a "capti- small quantity of PVC and caused a
ve" state, i.e., within an enclosed local smouldering fire that neverthe-
building. Practical experience has less released clouds of billowing smo-
shown that the smoke is much mo- ke. The damage was assessed at se-
re dangerous to human beings veral millions DM.
than the heat (flames). According
to fire statistics, two-thirds of all The high loss was caused by the hy-
deaths due to fire result from suf- drochloric acid vapours which inevita-
focation and smoke poisoning, bly form in the combustion of PVC.
while one-third is caused by burns These gases attacked all unprotected
and collapsing buildings. These metal surfaces of the film making line,
observations confirm the domi- which had to be scrapped as a result.
nant role of smoke as a threat to Kalle's works fire department contac-
human beings in the event of a fire. ted the Hersfeld-based BSH com-
Moreover, hot smoke and combu- pany, their traditional fan supplier,
stion gases, in conjunction with and requested the development of a
thermal buoyancy effects, may lite- fan that would be able to extract smo-
rally "pre-heat" those building ke, fumes and toxic matter via the
areas to which the flames themsel- roof. Starting out from their standard
ves have not yet spread, thus pa- roof fan range, BSH (now TLT) set
ving the ground for their propaga- out to develop a roof-mounted smoke
tion. exhaust fan rated for "higher tempe-
ratures". Following extensive in-hou-
These conditions and hazards impo- se testing, the unit was finally classi-
se a whole set of requirements for an fied for 400°C service for a duration of
effective preventive fire protection 120 minutes.
strategy. The main objectives can be
summarized thus: Thus, the "smoke exhaust fan" was
born, although a market warranting
• Smoke extraction volume production or even promising
• Smoke dilution significant sales revenue had yet to
• Keeping escape routes and be identified. At the time, stationary
smoke exhaust fans were virtually un-
rescue accessways clear
known as a preventive fire protection
of smoke so as to facilitate solution. Through word of mouth in
the fire-fighting effort. the fire-fighting and consulting ex-
perts' community and an intense in-
To prevent the fire from spreading, formation and sales promotion effort
the heat of combustion must be re- directed by BSH at fire authorities,
moved from the building along with building supervision offices, archi-
the smoke. In modern building servi- tects and specifiers, the potential of
ces engineering, mechanical smoke smoke/fume exhaust fans was soon
and heat exhaust systems have the- established. In addition to the roof-
refore become a standard feature sin- mounted fan versions, the market
ce they effectively protect lives and soon demanded diverse other desi-
property. The heart of such a smoke gns since smoke and fumes cannot
and heat exhaust system are the always be extracted via the building
smoke exhaust fans. roof. Thus, BSH began to develop
smoke exhaust fans for wall installati-
on and floor-mounted units for use in-
side buildings. Today, Turbo-Luft-
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS
5.0 Legal basis However, each LBO code applies to "Structures shall be designed
all construction activities and equip- such that the outbreak of fire and
Although in Germany the conference ment. It is supplemented by building the propagation of flames and
of the Ministers of Urban Planning, law standards for classified construc- smoke are effectively prevented,
Housing and Construction (ARGE- tion materials, components, and spe- and that human beings and ani-
BAU) has imposed a model building cial components. mals can be rescued and an effec-
code (MBO) for reference by the fe- tive fire-fighting effort can be laun-
deral states, building law has in es- ched should a fire nevertheless oc-
A review of the building codes for the
sence remained the responsibility of cur."
various federal states with regard to
the latter.
fume and smoke extraction reveals a
As a result, applicable building law is common principle that features in all
enshrined in the State Building Code German building regulations. Refer-
(LBO) of each federal state. It follows ring to smoke and heat control, sec- Considering this being a general for-
that fire protection requirements vary tion 17(1) contains the following pro- mulation, the aim of the efforts can be
regionally. vision: seen clearly though.
Supplementary guidelines and acknowledged rules of engineering practice Building rules list
MRA CE, ÜZ
EN 12101-3 testing
DIBt approvals
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS
6.0 Fundamentals
• an inflammable substance
• oxygen
6.2 Propagation
d
°C
e
which will accumulate under the cei-
pe
fir
50
e o
ling of the building, spreading both
(5
fir vel
th
er
horizontally and vertically from there.
de
of
ov
n
lly
The key function of a smoke and heat
sh
io
Fu
at
a
exhaust system is to remove smoke
Fl
in
ig
from the building. Depending on the
nature of the fire source, the smoke Or
may be more or less toxic. The room
in which a fire has started may fill with
enormous volumes of smoke in just a
Temperature
few minutes.
Smoke
Time
6.4 Operating principle of mecha- nings. If these openings are adequa- chanical smoke exhaust equipment.
nical smoke and heat exhaust sy- tely sized for the dimensions and Fig. 2 illustrates this state. If one ta-
stems combustible content of the room, the kes into account all relevant planning
Depending on the nature of the bur- evacuation of hot smoke and the in- aspects, natural and mechanical
ning substance, varying degrees of gress of fresh air will be ensured. Ide- smoke exhaust systems emerge not
smoke formation (density) may be an- ally, as the fire progresses, the gas as competing solutions but as sepa-
ticipated. Originating in a small area, cushion under the ceiling should re- rate strategies complementing each
these gases eventually rise to the cei- main at a constant height above floor other effectively. Apart from the buil-
ling where they will form a smoke lay- level (equilibrium condition bet- ding situation, the expected thermal
er which initially does not mix with the ween inflowing air and extracted conditions in the event of a fire are a
cold air underneath. As the fire gains smoke), so that enough visibility and key consideration.
force, more and more combustion breathing air remains available un-
gas accumulates under the ceiling of derneath for human beings to leave
the closed room. Eventually the gas the room and to conduct fire-fighting
cushion expands downwardly, to- operations. This equilibrium can be
wards the floor. Once it has fallen to achieved via simple openings toward
below head level, the prospects for the outside, as well as through me-
rescuing people and controlling the fi-
re become critical.
When the room containing the fire is
opened at specific (planned) points,
the thermal and smoke load is redu-
ced by the resulting inrush of air and
the simultaneous extraction of smo-
ke. Initially, a pressure equalization
with the surrounding ambient areas
takes place. With time, an underpres-
sure forms in the lower half of the Smoke cushion
room and more fresh air enters
through the appropriate access ope-
Unobstructed visability
The smoke exhaust fan is the heart of any mechanical smoke and heat exhaust system
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS
6.5 Smoke exhaust fans The approval certificates of the Buil- Key requirements under section
ding Supervisory Authority, issued by 45(1) of the Building Products Act re-
The relevant requirements are defi- the German Institute of Building late to the following properties:
ned by the European product stan- Technology, a corporation under pub- • mechanical strength
dard DIN EN 12101, Part 3 ("Smoke lic law, acknowledge compliance with • stability
and heat control systems – Specifica- the technical requirements of the Buil- • fire protection
tion for mechanical smoke and heat ding Rules List B2. • hygiene
exhaust ventilators"). All TLT smoke
• health
exhaust fans are tested to this stan- This document is published by the
• environmental protection
dard and meet its severe require- German Institute of Building Techno-
• safety for use
ments. logy (Deutsches Institut für Bautech-
• acoustic insulation
nik, DIBt).
In addition, German building law re- • energy savings
quires each fan to be generally ap- The Building Rules List "B", Part 2, in- • thermal insulation
proved by the Building Supervisory cludes construction products which The essential requirements are detai-
Authority. are sold and introduced into commer- led in the basic documents under Ar-
ce under regulations governing the ticle 12 of the Council Directive
In accordance with this requirement, our
implementation of European Commu- 89/106/EEC of December 12, 1988.
smoke exhaust fans possess the sup-
nity directives, with the exception of
plementary General Building Supervi-
regulations for the implementation of
sory Approval issued by the German In-
the Construction Products Direc-
stitute of Building Technology (DIBt),
tive,where such directives do not re-
Berlin. Significant advances in standar-
flect key requirements of section 5(1)
dization of preventive fire protection
of the German Construction Products
technology have allowed these stan-
Act and additional proof of suitability
dards to be integrated into building law.
for use is required under German Building Rules List "B",
With the inclusion of smoke exhaust
building codes to meet these require- Edition 97/1 (Excerpt)
fans into the Building Rules List, their in-
ments. Such construction products The Building Rules List "B" is a
stallation has become permissible only
must bear the DE label in addition to compilation of construction pro-
where the relevant units are tested and
a conformity label according to the ducts whose introduction into com-
certified to legally valid standards.
building codes of the German federal merce and sale is subject to regu-
6.5.1 Suitability testing and certifi- states. The specific requirements of lations of European Union member
cation by the Building Super- section 5(1) of the Construction Pro- states – including Germany – and
visory Authority ducts Act not met by the directives of signatory states of the Agree-
are stated in column 4 of the Con- ment on a European Economic
Only one test institute in Germany is struction Rules List "B", Part 2. Co-
accredited to perform suitability Area, and which bear the CE label.
lumns 5 and 6 indicate which suitabi- For smoke exhaust fans, the Buil-
testing of smoke exhaust fans accor- lity and conformity certificates a pro-
ding to the test and inspection provi- ding Rules List "B", Part 2, shall be
duct must possess to fulfill such key applicable.
sions of EN 12101-3. This is the test requirements of the German state
institute of the Technical University of building codes.
Munich (Domestic Services Re-
search Laboratory).
Complete test rig for roof-mounted smoke exhaust fans. Fumes are Heat-insulated repair switch, cooling air inlet nozzle
extracted from a furnace and returned to it via a duct connected to the
fan outlet.
6.5.3 Test conditions and criteria refore been our policy to test them on for which TLT smoke exhaust fans
a voluntary basis in conjunction with are built.
Our smoke exhaust fans are functio-
the fan system. For each fan series, a
nally tested under virtually realistic
minimum of two (up to a total of five)
mounting conditions. Each fan series
specimens had to be tested depen-
is run in smoke extraction mode ac-
ding on type and model. The number
cording to its appropriate temperatu-
of specimens reflects the criteria set
re/time category for at least the speci-
forth in the test standard as well as
fied minimum operating duration; in
the diversity of application conditions
most cases, the test is continued for
much longer (Table 1).
6.5.4 Suitability testing criteria
• Volume flow decrease over the test Temperature / Time Category according to EN 12101, Part 3
interval () 10%)
Category F300 F200 F400 F600 F842 not assigned
• Reduction in static pressure head
over the test interval () 20%) Temperature (¡ C)
as determined
• Surface temperature increase on in- according to 300 200 400 600 842 by supplier
sulated fans must not exceed 180 K EN 12101-T3
at any one point Insulated fans
as determined
minimum operating 60 120 120 60 —
by supplier
6.5.5 Tests duration (min)
6.5.7 Fan sizing The air flow rate through the supply – installation room cooling
openings should be ) 3 m/s.
As a rule, any smoke and heat ex- – thermal installation
haust system must be sized in con- 5. Determine the total pressure loss
formance with applicable laws and across the system. – use of tested and approved acces-
standards. This can only be accom- 6. Select the appropriate fan sories (e.g., flexible connectors,
plished through cooperation between spring-type antivibration mounts, si-
the specifier and the building supervi- Often it may appear expedient to use lencers, shutoff dampers)
sory authority. As a result, the calcu- the fan for normal room ventilation
lation steps and sizing criteria outli- purposes as well. In this case, a drive – uninterruptible power supply
ned below should only be viewed as a motor with two or three operating
guide. speeds may be selected. The lower
rpm level is then used for normal ven-
ting, while the higher speed is activa-
Sizing steps ted in the event of a fire.
7.0 Fire load determination The theoretical fire compartment area distribution as well as the combustion
according to DIN 18230, A expressed in m2 will therefore not behaviour of the inflammable sub-
Parts 1 & 2 always be the same as the surface stances. Obviously, the mass of un-
area of a smoke compartement of a protected paper, cardboard, textile
A method of determining the fire load building to be assessed. In practice material, etc., that will be consumed
and its relevant factors is defined in one room or flights of rooms having a by fire in unit time is much larger than
DIN 18230, Parts 1 & 2. According to smaller surface area than the fire the corresponding mass of wood or
this standard, the fire load q (in compartment concerned will depend packaged products.
kWh/m2) is the aggregate amount of on the demands of the mechanical
heat that can be released by all com- smoke extraction. For our purpose we Depending on the material and its net
bustible materials in a given fire zone must calculate the room surface area calorific value and storage density,
having a theoretical surface area A (in to be protected by the mechanical the combustion factor mi will typically
m2). This can be written as follows: smoke extraction system. vary between 0,2 and 1,7.
Excerpt from the Addendum to DIN Extract from annex to DIN 18230 - part 1
18230, Part 1. For details refer to DIN 18230, part 1 + part 2, preliminary standard
(More detailed data are given in DIN Compact- mi-
18230, Parts 1 & 2) No. Material
ness % factor
1 Wood and wooden materials
spruce wood
boards
squared timber 40 mm x 40 mm
squared timber 100 mm x 100 mm
squared timber 200 mm x 200 mm
unpainted cardboard
7.1 System design in As soon as the fire brigade has arri- A note in the standard tells us that the
accordance with ved at the scene, it will take charge of presence of a sprinkler system justi-
DIN 18232, Part 5 rescue operations and can also de- fies the selection of the next lower di-
termine whether or not the mechani- mensioning category. This statement
The new standard DIN 18232, part 5, cal smoke exhaust system should re- must be viewed as exceedingly pro-
applies to large rooms with a mini- main in operation. The time between blematic. A discharge of water from
mum interior height of 3 m. However, the start of the initiation of the fire and the sprinkler system into the accumu-
it is not suitable for rooms with statio- the arrival of the fire brigade is there- lated smoke layer will definitely in-
nary gas extinguishing equipment, fore decisive. Where a company fire crease the amount of smoke to be ex-
storage rooms with storage heights department is in place, an interval of tracted. In addition, the water literally
exceeding 1.5 m, hazardous material 5 minutes is typically assumed. With forces the smoke downwards into the
storage areas, and hazardous duty volunteer fire brigades and under un- escape routes, which should be kept
rooms. usually adverse conditions, as much clear by all means.
The calculation of the volume flow to as 20 minutes may pass. In the nor-
be extracted is based on the so-called mal case, calculations will be based
on an average fire development time Our recommendation, therefore, is
dimensioning category. To obtain the
of 10 minutes. to leave the mechanical smoke ex-
appropriate dimensioning category it
haust system running for as long
is necessary to determine the under- Once this interval has been defined in as occupant protection is still an
lying fire development time and the fi- consultation with the expert and/or lo- issue, and to ensure that the
re propagation rate. The fire develop- cal fire department, the fire propagati- sprinkler system will be triggered
ment time is the interval between the on rate remains to be determined. It after the smoke exhaust fans.
outbreak of the fire and the start of fi- depends on the combustible materi-
re-fighting operations. In any case, it als present in the various fire com- Moreover, the standard assumes
is assumed that the premises are pro- partments. smoke compartment surface areas in
tected by a fire alarm system in ac- the region of ) 1600 m2.
Combustible construction materials in
cordance with EDIN VDE 0832-2 The volume flow of smoke to be ex-
non-combustible packaging, for in-
(VDE 0833T2) with fire detectors as tracted and the fan temperature cate-
stance, have a particularly low fire
per DIN EN 54-7, or else that appro- gory can now be determined from the
propagation rate. On the other hand,
priately trained personnel is conti- exhaust flow rate tables, depending
where substances such as benzene
nuously present. The mechanical on the desired depth of the low-smo-
or rubberized products are stored, the
smoke exhaust system should be trig- ke layer, the dimensioning group, and
flames will spread very quickly.
gered by smoke detectors as soon as the energy release rate (a result of
Usually, an average propagation rate
possible,as only this way the evacua- the fire load calculation).
will be assumed.
tion of occupants, who are mostly un-
familiar with the building, can be en-
sured.
Fire Brigade
fire- departure of
message fire brigade
outbreak of fire
7.2 Design according to DIN 18230 events. Bearing this in mind, and in 7.3 Necessary number of air
and Quenzel accordance with a calculated equiva- changes
lent fire duration and the assumption
For guidance, Fig. 7 plots the curve of An attempt is made in Fig 8 (page
that no fire-fighting action is taken,
the unit-temperature in the fire com- 025) to give a guidance to the neces-
the unit-temperature curve permits an
partment over time. A few key critical sary number of air changes as a func-
approximate calculation of the tem-
temperatures have been marked in tion of the fire room height and pre-
perature increase (or fire temperatu-
the diagram as average points of oc- vailing fire load. It is assumed that the
re) to be expected . A real-case ana-
currence of the events identified. smoke concentration (kj2) in the room
lysis of fire loads and building situati-
is kept below 25% for 15 minutes af-
For the smoke exhaust system desi- ons yields an equivalent fire duration
ter the smoke exhaust system is ac-
gner the question arises in this con- of 20 – 55 minutes for most buildings,
tivated.
text which temperatures (and specifi- so that smoke temperatures of about
cally, which combustion gas tempera- 1020 to 1220 K (750 - 950°C) would This 15-minute interval was selected
ture) must be expected in case of a fi- have to be anticipated from the fire since it will normally give enough time
re. compartment. to evacuate occupants and initiate fi-
re-fighting measures.
A clear-cut law linking from the fire The temperature in the fire compart-
compartment temperature to the fire Smoke development is an important
ment will not reach this level if a smo-
load cannot be established because factor here since it has a major impact
ke and heat exhaust system genera-
of the diversity of effects governing on visibility in the room.
tes sufficient air changes from the
each individual fire. However, we can start.
identify a relationship between the fi-
re load and the equivalent fire durati- In this case the average fire tempera-
on tä, a term introduced in DIN ture should be described by the em-
18230. The equation incorporates the pirical formula:
factors w and c:
qr
tä = c · qr · w in min tm = 20 + 250 log (4 · t2ä · ) in °C
n·l
Beispiel
Example
940 Melting point of some stones
65
Duration of fire tä in minutes
Beispiel
Example
15
1600
␦
= 1,2 kg/m3
452/1252
500 t = 20°C
1400
1200
1000
516
-4
800
1000 rpm
additional available pressure ⌬pt Pa 씮
600
-6
610
425
750 rpm
400
-8
200
710
500
725 626
5000 10000 15000 20000 25000 30000 35000
Example 1
For planning and installation
Furniture warehouse in a multi-storey
please also refer to our
building, equipped with a wall-mounted Installation, Operation and
centrifugal smoke exhaust fan. Maintenance Instruction (MBW).
for 600°C – 120 minutes
Smoke
outlet
Make-up air inlet (wall opening) A
Storage area
10 m
– – – – – Fire-fighting access zone
– · – · – · Power supply and Control panel outside
control lines the fire compartment
24 m
Scale 1:150
Fig. 10 Floor plan and sectional view of a storage room = Customer supplied
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 2
ROOF-MOUNTED SMOKE EXHAUST FAN FOR 400/620°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany BVD SERIES 028
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Example 2
Industrial shed ventilation and smoke
exhaust system using 3 roof-mounted
smoke exhaust fans.
400/620°C – 120 minutes
Make-up air
inlets (wall openings)
A
10 m
Control panel
Corridor area = Escape route
Door admitting
make-up air Switch location
B
25 m
Scale 1:150
Smoke outlet
Example 3
For planning and installation
Industrial shed ventilation and smoke
please also refer to our
exhaust system using wall-mounted Installation, Operation and
axial flow exhaust fans Maintenance Instruction (MBW).
for 200/300 ar 400°C – 120 minutes
10 m
Storage shed
B
25 m
Smoke outlet
Scale 1:150
Smoke
outlet
outlet
Fig. 12
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 4
AXIAL FLOW SMOKE EXHAUST FAN FOR 200/300/400°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany BVAXN 12/56 SERIES 030
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Example 4
For planning and installation
Ventilation and smoke exhaust system
please also refer to our
using one axial smoke exhaust fan for Installation, Operation and
200/300 oder 400°C – 120 minutes Maintenance Instruction (MBW).
Smoke
outlet
A
E90
10 m
Storage area
Door
admitting
Corridor = Escape route
make-up area Switch location B
25 m
Scale 1:150
Flexible connector,
Smoke exhaust duct, tested to
temperature-resistant
400°C – 120 minutes (e.g. steel)
3m
Smoke
outlet Axial smoke exhaust fan
(non-insulated, installed in fire compartment)
Scale 1:75
Section A–B
Fig. 13 Customer supplied
SMOKE EXHAUST FANS
APPLICATION EXAMPLE 5
AXIAL FLOW SMOKE EXHAUST FAN FOR 600°C
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany SERIES BVAXN 8/56 031
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
3,5 m
L90
Make-up
air inlet Axial smoke exhaust fan
3,5 m
(wall BVAXN 8/56 series
opening) Fan and flexible connector insulated by customer,
or fitted in separate (ventilated) room
(note motor cooling air requirement!)
Flexible
3,5 m
Fig. 14
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS
7.5 Installation notes for smoke maintenance specifications of DIN and its direction of impeller rotation
exhaust fans 4102, Part 12. must be verified.
By embracing intelligent solutions In practice, this means that the The circuit integrity, safety and relia-
at the planning stage and adopting connecting cables must not contact bility of the power supply must like-
a practice-oriented installation the fan casing and must be routed in wise be ensured. The system must be
strategy for the smoke exhaust appropriate mechanical protection maintained in good repair at all times.
systems. Its power supply must be ensured
system, users can save significant
The specifications further describe throughout the smoke extraction ope-
installation and maintenance ration. The option is essentially bet-
costs. the installation of switchgear compo-
nents and maintenance switches, ween a primary or secondary power
We are all familiar with practical ex- which must be provided in duly pro- supply. Secondary power may be de-
amples of fans virtually inaccessible tected form in areas not exposed to a rived from an emergency power unit
for maintenance, or whose disassem- fire or temperature hazard and in any or a second mains connection; in any
bly requires an unreasonable effort case, outside the fire compartment. case, it must be fully isolated from the
and can therefore be carried out only primary power source. The change-
on legal holidays – with the associa- As an example, consider the place- over between primary and secondary
ted penalty of immense cost. ment of maintenance switches outsi- supply must be automatic (second
de the fire zone. According to VDE mains connection). The power requi-
0113-1, such switches must be fitted rement of a smoke exhaust system
in the immediate vicinity of the fan for shall be rated under normal ambient
maintenance and repair purposes, conditions.
but this requirement applies only if the
fan is not in the line of sight of an ope- Another issue, ultimately, is the main-
rator at the switchgear cabinet. tenance of smoke exhaust fans. It
must be consistent with the fan ma-
It should also be noted that the fan's nufacturer's maintenance instruc-
radiant heat output must not interfere tions. As a minimum, component ope-
with maintenance switch operability, rability checks must be carried out at
and that the switch must be secured three-month intervals.
against unauthorized operation in its
energized state. (In no case shall If due regard has been paid to acces-
switches be mounted in the fire zone sibility at the planning stage, the follo-
without protection). wing functional checks can be perfor-
Installation example: BVAXN 8/56/1400 MD med quickly and economically:
Always remember when designing
circuits and control systems that the • Fan start-up test
Compliance with legal requirements fan's smoke extraction function must • Check of measuring and triggering
and the use of appropriate practical take priority over all other functions devices, smoke detectors and ma-
know-how constitute effective safe- the smoke exhaust system may have. nual start functions
guards against such errors.
Thus, where a fan is started or ener- • Visual inspection of fans and smoke
Indoor fan installation outside the gized via a suitable switchgear devi- exhaust dampers
fire compartment ce, all thermal or electrical monitoring • Review of smoke extraction scenari-
Fans for this application type must be components must be bypassed or de- os with regard to triggering, damper
heat insulated when installed in a energized, and all switching devices positioning and fresh air supply
ventilated room. Data concerning the must be rated for the projected
requisite nominal air flows which must (usually, maximum) fan rpm. The fan • Sample check of individual volume
be ensured to keep the air temperatu- speed must NOT be variable for the flows and comparison with the ac-
re in the installation room below 40°C duration of the fire, and indeed, such ceptance condition
under any fan operating condition are speed control would be counterpro-
available from the manufacturer upon ductive. Another important require-
request. ment is that all devices have under-
gone an appropriate acceptance pro-
Insulation in the form of wire-net mi- cedure.
neral fiber matting may be applied re-
troactively in a single layer. The This acceptance must be conducted
thickness of the lagging must exceed and documented at the system ope-
40 mm, at an apparent density > 90 rator's initiative. The acceptance tests
kg/m3. Note also that the insulation shall determine the system's full ope-
material for fire-resistant air ducting rability and appropriate installation,
must meet DIN 4102, Part 4. As re- and specifically the proper interaction
gards electrical wiring, routing and of all components. In the functional
execution requirements vary with the test, the fan's power consumption at
installation site. In any case, cables normal temperatures of about 20°C
shall conform to the circuit integrity must not exceed permissible values
SMOKE (FUME) EXHAUST FANS
INSTALLATION EXAMPLES
Fig. 1
200
a
Baffles
Opposed-
blade
damper
b
b = 0,6 x a
at least five, ideally
more (e.g., 8
baffles)
The flexible duct connector (two If a 2.5 x D inlet flow section cannot
nominal sizes > nominal fan size) be fitted, baffles should be used (for
ensures an additional improvement in An approach flow situation as shown configuration and sizes refer to Fig.
incoming flow conditions and superior in Fig. 6 will result in a greatly 5.1)
acoustic performance. impaired fan performance.
Fig. 5/5.1 Fig. 6/6.1 Fig. 7/7.1
SMOKE (FUME) EXHAUST FANS
INSTALLATION EXAMPLES
Maximum impact loss 50% reduced impact loss 70% reduced impact loss
In a free-outlet configuration, the On a free outlet system with 2.5 x D Diffusers can reduce impact loss by
dynamic pressure acting on the fan’s outlet duct, the entire surface area as about 70% when compared to the
annular surface area (fan surface determined from the nominal fan size configuration shown in Fig. 8.
minus hub surface) must be taken into may be used for the impact loss
account as impact loss. calculation (rectified flow).
Fig. 8/8.1/8.2
min.
0,5xD In large inlet chambers with multible air Please also observe other fan
streams, vortex effects may impair the technology fundamentals as described
airflow at the fan inlet. Performance in the relevant academic and trade
For in-chamber installation specified losses are an inevitable result. In this literature (e.g., TLT Fan Primer,
minimum distance must be observed. type of operating situation, the published by Promoter Verlag,
If multiple fans are mounted next to recommended anti-vortex baffle should Karlsruhe). Our staff will be glad to
each other, the distance between their either be fitted from the start or planned answer your questions on this subject.
bellmouths must be at least 0.5 D. in such a way it can be installed later.
Fig. 10 Fig. 12
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS
8.0 Individual system components b) the open position (during extrac- Such equipment is designated
tion of hot gases). ETK90, i.e., it has a fire resistance of
8.1 Smoke exhaust dampers 90 minutes at the ISO 834 unit-tem-
Moreover, their power supply must be perature curve (in the future, the rele-
Since work on the relevant European vant document will be EN 1363-1),
reliably ensured since a smoke ex-
standard (prEN 1366-10) is still conti- and its smoke extraction functionality,
haust damper is required to retain its
nuing, the relevant national approval based on the same curve, remains
opening and closing capability even
mechanisms have remained applica- ensured for the same period.
after 25 minutes of fire exposure, so
ble. In Germany, these are enshrined
that consistent with the Model Guide-
in the Building Rules List established
line for Ducting (draft 98), the exhaust
by the new Building Code (the cur-
duct equipment will remain operable
rently valid list is designated 99-1).
for at least 90 minutes.
According to this document, all smo-
ke exhaust dampers require approval
by the building supervisory authority. The drive units for smoke exhaust
dampers are tested for a fire resi-
Smoke exhaust dampers are known stance of 90 minutes. In the case of a
to have two safety positions: power failure, the de-energized drive
units must secure the damper in its
a) the closed position (standby, with open position, e.g., via a mechanical
or without fire resistance) locking feature.
DIN...
Engineering Standards Contents
EN...
Smoke exhaust fans DIN V Mechanical smoke exhaust systems
18232-6 Requirements for components
and suitability testing
Sizing of smoke exhaust systems DIN V Smoke and heat extraction systems
18232-5 Mechanical smoke exhaust systems
Requirements and design
Pressure-based smoke protection systems DIN 18232-7 Smoke and heat extraction systems
(draft) Pressure-based smoke protection
systems for safety staircases
8.3 Control of smoke exhaust the arrival of fire-fighting services. To Obviously, all triggering devices must
systems ensure the direct and immediate ac- be approved by the building supervi-
tivation of the smoke exhaust system, sory authorities. The layout and num-
8.3.1 Triggering devices and smoke extraction fans must be equip- ber of smoke detectors used must
single-range systems ped with automatic triggering devices conform to DIN VDE 0833-1.
that sense the presence of smoke
Smoke exhaust fans and fire protec- (smoke detectors).
tion dampers must be approved by
Smoke exhaust systems designed for
the German Institute of Building
human safety must not require ma-
Technology (DIBt) according to Buil-
nual activation, since the occupants
ding Rules List "B", Part 2, in conjunc-
at risk must be able to leave the buil-
tion with the relevant smoke detec-
ding safely within the first few minutes
tors. Compliance with the codes is
after a fire has started. If, in the cour-
demonstrated via certification tests
se of the planning process, the fire
performed by independent testing in-
authorities should insist on manual
stitutes.
activation by the fire brigade, the sy-
The smoke exhaust system is trigge- stem no longer qualifies as a smoke
red by pushbuttons or automatically exhaust installation for human safety,
via smoke detection switches. The since experience shows that it will
signals that activate the mechanical usually take 5 – 15 minutes for fire
heat and smoke exhaust installation fighters to arrive.
and move the fire protection and smo-
The foregoing does not apply where
ke exhaust dampers into their safety
smoke exhaust dampers form part of
position are transmitted by a control-
the smoke exhaust system. In this ca-
ler. The various devices cooperate to
se the fans may be integrated with the
ensure a high-speed fire detection,
wiring of the smoke exhaust damper
alarm, and smoke exhaust.
and the associated triggering device,
Past fire disasters have shown that which meets the same protection ob-
an effective rescue of human beings jective. Still, it must be possible to
can only be achieved through an ear- start the fans manually via pushbut-
ly and effective extraction of smoke tons.
from escape and safety routes until
Smoke-free layer
Pushbutton switch
Building
services
management
Air supply Controller
system
SMOKE (FUME) EXHAUST FANS
FUNDAMENTALS
8.3.2 Control via LON bus Bus communication between exhaust system and controller
(ICI)
Management
The integration of all equipment such
as central fire detection, emergency METASYS“
level
lighting and fire compartment doors operating station
into the building services automation
structure provides an overall functio-
N1 network, Ethernet using TCP/IP
nality and comprehensive control at 10 Mbps or
capability offering numerous benefits.
On one hand, it ensures that escape METASYS“ network
Automation
B
B3
C
350
H B1
40
A
Base plate 1) SDS Noise damping base
B
B3 M
Øe
110
NW
B3
cable-
A
duct
H1
d
Øk Y
Flexible connector B2
Øk
L (400°C) = 200 mm
L (620°C) = 90 mm
Customer-supplied base
B
Ø D1 Ø D1
Øk z x Ø d1 Øk
L
B4
Ø d1 Ø d1
Ø D2
2) Stud B4
Size Ø D A B3 H Ø D1 Ø D2 d bolt y Ø d1 Ø k zx Ø d1 L B1 B C H1 B2 Ø e NW
M min. - max.
315 638 560 460 695 386 369 14 12x25 8xM8 322 356 8 x 9,5 180 765 525 400 - 420 421 780 823 326 80
355 808 710 600 772 425 407 14 12x25 8xM8 360 395 8 x 9,5 180 975 675 450 - 540 565 810 981 365 80
400 808 710 600 848 468 451 14 12x25 12xM8 404 438 12 x 9,5 180 975 675 490 - 540 565 810 981 408 80
500 993 1000 880 923 571 586 18 16x25 12xM8 507 541 12 x 9,5 305 1265 965 600 - 830 850 850 1274 511 100
630 1272 1000 880 1337 712 730 18 16x25 16xM10 638 674 16 x 11,5 305 1265 965 750 - 820 850 900 1274 642 100
710 1272* 1160 1040 1337 785 798 18 16x25 16xM10 715 751 16 x 11,5 305 1425 1125 900 - 965 1000 930 1427 719 100
1) Flanges as per DIN 24 154, Series 3. An inlet wire guard can be 2) BVD 315/30-2 = 744 mm Dimensions in mm
fitted directly to the base plate or flanges. * 1500 mm with 710 XL
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES
BVD 400/30 Type Weight Speed Motor Nominal Volume flow (m3/h)
approx output current Free inlet Free inlet
at without with
400 V shutoff shutoff
50 Hz damper damper
800 ␦
[kg] [rpm] [kW] [A]
= 1,2 kg/m3
t = 20°C BVD 400/30-8 85 670 0,37 1,45 4900 4600
BVD 400/30-8/12 85 700/470 0,22/0,08 1,0/0,7 4900/3100 4600/2900
1500 rpm BVD 400/30-6 85 920 0,55 1,6 6250 6000
700 BVD 400/30-6/12 85 900/420 0,33/0,055 1,15/0,33 6250/3100 6000/2900
BVD 400/30-6/8 85 920/700 0,44/0,22 1,45/0,95 6250/4900 5950/4000
BVD 400/30-4 85 1410 1,5 3,5 9600 9150
BVD 400/30-4/8 85 1400/690 1,4/0,35 3,3/1,35 9600/4900 9150/4600
BVD 400/30-4/6 85 1430/960 1,6/0,6 3,9/1,8 9600/6250 9150/5950
600
-4 Acoustic levels in the room (inlet side)
Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
500 Relative acoustic power level
Speed Acoustic level 1)
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
470 77 64 49 3,1 5,6 8,5 20,8 23,9 20,7 24,3 38,6
400
670 86 75 61 4,4 4,3 7,4 18,0 20,2 22,2 18,7 27,0
920 92 83 69 5,0 4,5 6,7 10,7 18,6 21,7 18,4 21,9
1410 98 90 76 7,3 8,8 2,7 10,4 18,0 20,3 21,4 18,2
1000 rpm Influence of the self-activating shutoff damper: +3 dB
300
Additionally available pressure pt1 [Pa] ➞
400
Acoustic levels above roof (outlet side)
Conditions: free field, measurement area S = 117 m2, Ls = 20,7 dB,
background noise influence K1 = 0 dB, directional factor -3 dB
300
750 rpm
Speed Acoustic level 1) Relative acoustic power level
-8 at V max. Lw rel. = Lw – Table value
200 Octave center frequency [Hz]
rpm Lw [dB] LwA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
per s
dam teristic 470 78 69 45 6,8 4,9 3,7 14,8 13,8 19,6 23,8 31,2
500 rpm toff c
Shu chara
n c e 690 86 78 54 10,5 5,6 3,2 11,3 12,4 17,8 21,9 29,2
100 -12 re sista
950 92 87 62 10,7 5,6 5,5 7,3 9,9 14,4 18,3 25,2
1420 101 97 73 8,0 8,0 6,0 10,0 9,0 15,0 18,0 19,0
Influence of the self-activating shutoff damper: + 2 dB
2000 4000 6000 8000 10000 12000 14000 16000 1) L = Total acoustic power level
W LWA = Total acoustic power level LPA = Sound pressure level, r = 4 m, 0°
Volume flow V [m3/h] ➞ Acoustic levels apply to free intake at V max without shutoff damper.
ROOF-MOUNTED SMOKE EXHAUST FANS
BVD SERIES
BVD 630/30 Type Weight Speed Motor Nominal Volume flow (m3/h)
2000 approx output current Free inlet Free inlet
at without with
400 V shutoff shutoff
50 Hz damper damper
1500 rpm [kg] [rpm] [kW] [A]
1800
-4 ␦ BVD 630/30-8 240 710 2,2 5,4 18300 17400
= 1,2 kg/m3
BVD 630/30-8/12 240 720/470 2,4/0,8 6,8/3,6 18300/11800 17400/11000
t = 20°C
BVD 630/30-6 240 945 5,5 12,7 24800 23200
1600 BVD 630/30-6/12 240 920/460 6,3/1,5 16,6/6,1 24800/11800 23200/11100
BVD 630/30-6/8 240 970/720 4,8/2,4 11,4/6,7 24800/18300 23200/17400
BVD 630/30-4 320 1460 18,5 38 38000 36000
BVD 630/30-4/6 350 1460/980 18/6,0 36/14 38000/24800 36000/23200
1400 BVD 630/30-4/8 350 1460/710 20/5,5 39/16,2 38000/18300 36000/17400
1200
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
1000 rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
470 87 73 59 3,4 5,2 8,3 21,1 23,6 28,1 33,1 38,3
710 96 86 72 5,4 4,2 6,5 11,2 19,8 23,4 28,2 33,3
945 101 90 76 9,6 1,3 9,8 14,1 18,5 24,6 29,0 23,0
800 1000 rpm 1460 111 104 91 6,0 7,0 3,0 10,0 13,0 17,0 21,0 26,0
Influence of the self-activating shutoff damper: +3 dB
-6
Additionally available pressure pt1 [Pa] ➞
1400
Acoustic levels in the room (inlet side)
Conditions: A = 173,2 m2 Sabin, measuring surface S = 100 m2, Ls = 20 dB,
background noise influence K1 = 0 dB, room influence K2 = 5,2 dB
1200
Speed Acoustic level 1) Relative acoustic power level
at V max. Lw rel. = Lw – Table value
Octave center frequency [Hz]
rpm Lw [dB] LWA [dB] LPA [dB] 63 125 250 500 1000 2000 4000 8000
1000
710 103 93 78 5,0 3,0 13 14 15 18 23 28
Specifications:
Volume flow m3/h
Temperature (design) 20°C
Temperature (max./withstand time) °C/min
Additionally available pressure Pa
Motor speed rpm
Motor output kW
Motor winding V
BVD
Current consumption A
Operating voltage V
Frequency Hz
Acoustic pressure level LPA dB
above roof level, r = 4 m
Weight kg
Type: BVD
Carryover
– 046 –
Unit price Total
Item
Qty. Description
No.
2 2
Accessory equipment
Surface protection
• Polyester powder coating (standard colour: RAL 7030)
• Wire guard on inlet side (with free inlet configurations)
• Wire guard on outlet side
• Self-activating shutoff damper for free inlet systems, with
nozzle shaped inlet and mounting flange
or • Self-activating shutoff damper for duct connection, with
connecting flanges on both ends
• Flexible connector made of temperature-resistant
compensator fabric, with connecting flanges on both
ends.
• Matching flange
• Steel flat roof base made of sendzimir-galvanized sheet
steel, with interior insulation
- for flat roofs
- for inclined roofs, __° gradient
or • Steel flat roof base made of sendzimir-galvanized sheet
steel, double-shell design, with building supervision
approval
- for flat roofs
- for inclined roofs, __° gradient
• Outlet attenuator SDI, with vertical air outlet
Consisting of the interior core made of galvanized
perforated sheet, integrated into the fan housing and the
non-inflammable insulation material covered with a layer
of non-woven glass fiber
Tested to EN 12101-part 3
Silencing: appr. 5 to 7 dB
• Silencing base SDS for inlet-side silencing, consisting of
the base construction with roof integration flange made of
sendzimir-galvanized sheet steel and the duct-attenuator
with galvanized perforated sheet cover.
For easy wiring the base is equipped with an integrated
cable duct.
Tested to EN 12101-part 3
- for flat roofs
- for inclined roofs, __° gradient
• Additional surface protection:
- Acoustic silencing hood
- Acoustic silencing base
Note: Please observe our Installation, Operating and
Maintenance Instructions (available upon request).
AXIAL SMOKE EXHAUST FANS
PRODUCT RANGE
TECHNICAL DESCRIPTION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 047
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Axial smoke exhaust fans of series: BVAXO · BVAXN 12/56 · BVAXN 8/56 · BWAXO · BWAXN
Characteristic curves as of page 054 Characteristic curves as of page 078 Characteristic curves as of page 101
BVAXO series BVAXN 12/56 series BVAXN 8/56 series
Temperature/Time category acc. Temperature/Time category acc. Temperature/Time category acc.
EN 12101 - part 3: EN 12101 - part 3: EN 12101 - part 3:
F 200 200°C - 120 min. F 200 200°C - 120 min. F 600 600°C - 120 min.
F 300 300°C - 120 min. F 300 300°C - 120 min.
F 400 400°C - 120 Min. F 400 400°C - 120 min.
Appropriate for installation inside of
Appropriate for installation in- and Appropriate for installation in- and fire-zone (cooling-system to be
outside of fire-zone. outside of fire-zone. provided by customer)
Product range: Product range: Product range:
6 sizes 14 sizes 10 sizes
ranging from 400 to 1120 mm diam. ranging from 355 to 1600 mm diam. ranging from 500 to 1600 mm diam.
Volume flow up to 100 000 m3/h Volume flow up to 250 000 m3/h Volume flow up to 180 000 m3/h
total pressure increase total pressure increase total pressure increase
up to appr. 900 Pa up to appr. 2 500 Pa up to appr. 1 400 Pa
Also available with acoustic and Also available with acoustic and Blades of 400°C/120 min. version are
thermal insulation. thermal insulation. non-adjustable.
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300°C - 120 MIN 048
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Mmax.
2)
➞
Øk
zxd
L i. d.
ØD
Weight
[kg] Motor sizes / Shaft Dia.
Size1) i. d. Øk ØD zxd L Mmax.
(without Type B3
motor)
400 401 438 468 12 x 9,5 188 455 11/16* 90/24 100/28*
500 504 541 571 12 x 9,5 225 570 19/26* 90/24 100/28 112/28* 132/38*
630 634 674 712 16 x 11,5 286 450 27 90/24 100/28 112/28 132/38
800 797 837 875 24 x 11,5 350 575 38 90/24 100/28 112/28 132/38
1000 1003 1043 1081 24 x 11,5 415 805 80 112/28 132/38 160/42 180/48
1120 1124 1174 1214 24 x 11,5 450 825 110 132/38 160/42 180/48 200/55
1) For vibration-damped installation an extension casing will be required with certain fan sizes. Dimensions in mm
* Possible with extension casing only
Dimensional and design
2) available as "turning-anti-clockwise” (seen in airflow-direction) only
changes reserved.
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300°C - 120 MIN 049
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
ød1 i.L.
appr. 60
i.d2
i.d2
400 562 403 78 300 248 218 436 406 370 300 5 x 9,5 403 438 468 12 x 9,5 80 50
500 708 509 98 375 285 255 510 480 460 380 5 x 9,5 506 541 571 12 x 9,5 80 50
630 875 640 95 470 361 321 647 607 550 470 5 x 11,5 637 674 712 16 x 11,5 100 70
800 1081 801 115 585 425 385 775 735 730 640 5 x 11,5 800 837 875 24 x 11,5 100 70
1000 1351 1009 145 730 512 466 927 881 830 740 5 x 14 1006 1043 1081 24 x 11,5 100 70
1120 1470 1130 160 760 547 501 997 951 920 820 5 x 14 1133 1174 1214 24 x 11,5 110 90
1) Connecting dimensions in 2) Height under load will be * all accessories, except duct Dimensions in mm
accordance with DIN 24 154 – communicated upon specification feet and duct extension, are
Series 3 (value is calculated individually for packed separately Dimensional and design
each purchase order). changes reserved.
AXIAL SMOKE EXHAUST FANS
BVAXO SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300°C – 120 MIN 050
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
wire guard
zxd L3
500 657 705 68 12 504 541 571 12 x 9,5 634 282 674 712 16 x 11,5 600 280 60 225 390 200
630 852 900 90 14 634 674 712 16 x 11,5 797 355 837 875 24 x 11,5 750 330 70 286 465 200
800 1015 1063 90 14 797 837 875 24 x 11,5 1003 446 1043 1081 24 x 11,5 950 520 200 350 550 200
1000 1221 1269 90 14 1003 1043 1081 24 x 11,5 1261 562 1311 1391 24 x 11,5 1200 640 240 415 690 200
1120 1374 1434 100 18 1124 1174 1254 24 x 11,5 1415 630 1465 1545 24 x 11,5 1340 730 250 450 820 300
Acoustic level Starting from this value, the A-weigh- ning, respectively. The values given
ted acoustic power level LWA and the were taken from measurements as
relative acoustic power level LWrel. per EN 25136 (formerly DIN 45 635,
The total acoustic power level Part 9) duct testing method.
can be determined using the tables
LW.Vent. (in dB) of an axial smoke ex- below. These values are available as
haust fan can be obtained directly the acoustic power emitted into the
from the characteristic data sheets for duct and as the acoustic power emit-
each operating point. ted from the fan inlet or outlet ope-
1. Acousting power level emitted into the duct Axial Smoke Exhaust Fan BVAXO (without guide vanes)
The level of acoustic power an axial smoke exhaust fan Portion 1.2 at mid-octave frequency [Hz]
emits into the ducting is used for calculating the sound po- z·n
fD = ––––
60
Portion 1.1
wer characteristics of downstream systems, e.g., silencers. 63 125 250 500 1000 2000 4000 8000
The levels are calculated as follows: 500 4 12 9 7 5 11 12 14 15
Lwvent. [dB] = total acoustic power emitted by the fan, 250 6 9 7 4 10 12 13 15 17
(please see respective characteristic curve
125 7 6 4 10 11 13 14 16 21
sheets)
63 8 2 8 10 11 13 15 19 24
LwA vent. [dB] = A-weighted acoustic power level, according
to the equation 31,5 8 6 8 9 11 13 17 21 26
Blade frequency of the fan ist calculated from the number of bla-
des z and the fan speed n [rpm].
z · n [s-1]
fD = ––––––
60
Lwvent.
LwAvent.
Amount-linear level
Lwrel.vent.
Amount A
fD Note:
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above
Hz 63 125 250 500 1000 2000 4000 8000 spreadsheets.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXO 200°C - 120 MIN SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 052
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 30 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 60 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 401 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 401 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,126 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,126 m2
pd
100 400
0,54
45° Blade pitch angle 45° Blade pitch angle
90 355
80 315
0,52 0,53
Total pressure increase ⌬ pt [Pa] →
40°
50 0,47 200
45 180
25° 30° 25° 30°
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
V̇ [m3/h] → V̇ [m3/h] →
0,45
0,5
0,56
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
V̇ [m3/s] → V̇ [m3/s] →
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
c [m/s] → c [m/s] →
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
25
31,5
40
50
63
80
100
125
160
200
250
315
400
pd [Pa] → pd [Pa] →
Shaft power input requirement:
93 107
45°
=
35°
V [m3/h] · ⌬pt [Pa]
30° 40°
· 1000 · 3600
89 35° 103
· 1000 · 3600
79 93
Pw [kW] =
Pw [kW] =
Lw [dB]
77
Lw [dB]
91
75 89
73 87
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 504 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 504 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,2 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,2 m2
200 710
180 630
160 560
140 500
pd
=
=
125 0,51 45° Blade pitch angle 450 0,51
0,49
pd
90 0,48 315
35° 32,5° Blade pitch angle
80 280
32,5° 0,44 30°
71 0,44 30° 250
63 224
56 200
25°
20° 25° 20°
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
V̇ [m3/h] → V̇ [m3/h] →
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
V̇ [m3/s] → V̇ [m3/s] →
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
c [m/s] → c [m/s] →
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
20
25
31,5
40
50
63
80
100
125
160
200
250
315
pd [Pa] → pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:
95 107
=
=
93 105
V [m3/h] · ⌬pt [Pa]
V [m3/h] · ⌬pt [Pa]
91 103
· 1000 · 3600
· 1000 · 3600
32,5° 81 93
Pw [kW] =
Pw [kW] =
20°
Lw [dB]
79 91
Lw [dB]
77 89
75 87
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C – 120 MIN Subsequent pitch variations are not possible. 055
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 32 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 504 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,2 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2
1250
1120 160
1000 140
=
900 125 0,62
pd
800 112 0,60
45° Blade pitch angle
=
710 0,47
100
pd
630 90 0,58 40°
0,46
355 35° 50
20° 25° 30°
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
7 100
8 000
9000
2,8 10 000
3,15 11 200
3,55 12 500
4,0 14 000
4,5 16 000
18000
5,6 20 000
6,3 22 400
7,1 25 000
8,0 28 000
V̇ [m3/h] → V̇ [m3/h] →
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
2,0
2,24
2,5
5,0
V̇ [m3/s] → V̇ [m3/s] →
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
c [m/s] → c [m/s] →
63
80
100
125
160
200
250
315
400
500
630
800
1 000
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
pd [Pa] → pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:
115 91
=
=
113 35° 89
V [m3/h] · ⌬pt [Pa]
V [m3/h] · ⌬pt [Pa]
32,5°
· 1000 · 3600
111 87
· 1000 · 3600
45°
35° 109 25° 30° 85
37,5° 40°
107 83
37,5° 105 20° 81
45° 103 79
·
·
101 77
Pw [kW] =
Pw [kW] =
40°
Lw [dB]
99 75
Lw [dB]
97 73
94 71
( ) S( )
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 46 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 94 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2
400
BVAXO 9/630/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 9/630/D - n = 2880 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
1600
355 1400
315 1250
280 1120
= = 0,61
pd
0,61
pd
BVAXO
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
V̇ [m3/h] → V̇ [m3/h] →
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
V̇ [m3/s] → V̇ [m3/s] →
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
c [m/s] →
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
c [m/s] →
16
20
25
31,5
40
50
63
80
100
125
160
200
250
pd [Pa] →
63
80
100
125
160
200
250
315
400
500
630
800
1000
pd [Pa] →
Shaft power input requirement:
103 118
=
101 116
V [m3/h] · ⌬pt [Pa]
99
· 1000 · 3600
· 1000 · 3600
114
32,5° 35° 97 112
30° 95
45° 37,5° 110
25° 40° 93 35° 108
20° 37,5° 91 32,5° 106
·
89
Pw [kW] =
104
Pw [kW] =
87
Lw [dB]
Lw [dB]
102
85 100
83 98
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible.
056
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 94 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 30 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 634 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 797 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,31 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,5 m2
1250
1120 125
1000 112
900 100
=
pd
800 90 0,67
45° Blade pitch angle
710 80
0,64
630 = 71
0,59 40°
Total pressure increase ⌬ pt [Pa] →
560 63
0,59
37,5°
500 0,48 0,58 56
0,55 35°
450 50
0,56
0,50
400 30° Blade pitch angle 45
32,5°
0,51
355 40
20° 25° 20° 25° 30°
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
V̇ [m3/h] → V̇ [m3/h] →
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
V̇ [m3/s] → V̇ [m3/s] →
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
c [m/s] → c [m/s] →
31,5
40
50
63
80
100
125
160
200
250
315
400
500
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
pd [Pa] → pd [Pa] →
Shaft power input requirement:
112 92
=
110 40° 90
V [m3/h] · ⌬pt [Pa]
108 88
· 1000 · 3600
98 78
Pw [kW] =
Pw [kW] =
96 76
Lw [dB]
Lw [dB]
94 74
92 72
Ai fl di i D( i l ) Pl i i f Ai fl di i S( i i l ) Vl dd d d fi
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 39 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 60 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 797 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 797 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,5 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,5 m2
250
224 450
200 400
=
180 355
pd
0,68
pd
=
315 45° Blade pitch angle
160 0,67
45° Blade pitch angle
0,65
0,64
140 280
40°
0,63
125 250
40° 0,60
Total pressure increase ⌬ pt [Pa] →
37,5°
Total pressure increase ⌬ pt [Pa] →
0,59 224
112
37,5° 200 35°
100 0,56
0,56
90 35°
180
32,5°
80 160
0,50 32,5° 0,52
71 140 30°
20° 25° 30° 20° 25°
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
V̇ [m3/h] → V̇ [m3/h] →
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
V̇ [m3/s] → V̇ [m3/s] →
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
c [m/s] →
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
c [m/s] →
25
31,5
40
50
63
80
100
125
160
200
250
315
400
pd [Pa] →
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:
40° 96 106
=
=
94 104
V [m3/h] · ⌬pt [Pa]
37,5°
V [m3/h] · ⌬pt [Pa]
45°
Total acoustic power level
32,5°
Total acoustic power level
102
· 1000 · 3600
92
· 1000 · 3600
32,5° 45°
30° 90 100
25° 37,5° 88 25° 40° 98
35° 86 96
20° 20° 35° 94
84
·
·
30° 92
Pw [kW] =
82
Pw [kW] =
90
Lw [dB]
Lw [dB]
80
78 88
76 86
Ai fl di i D( i l ) Pl i i f Ai fl di i S( i i l ) Vl dd d d fi
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible. 057
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 51 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2
125
BVAXO 9/1000/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
315
BVAXO 9/1000/D - n = 980 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
112 280
=
0,57
100 250
pd
0,56 =
90 224 0,61
50° Blade pitch angle
80 0,54 200 0,60
71 180
45°
0,58
63 0,52 160
0,56
Total pressure increase ⌬ pt [Pa] →
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
V̇ [m3/h] → V̇ [m3/h] →
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
V̇ [m3/s] → V̇ [m3/s] →
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
c [m/s] → c [m/s] →
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
pd [Pa] → pd [Pa] →
Shaft power input requirement:
90 106
=
25° 88 104
V [m3/h] · ⌬pt [Pa]
· 1000 · 3600
25°
·
76 92
Pw [kW] =
Pw [kW] =
74 30° 35° 90
Lw [dB]
Lw [dB]
72 32,5° 88
70 86
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 38 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2
500
BVAXO 9/1000/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 12/1000/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
224
450 200
400 = 180
0,58
355 160
pd
315 140
= 50° Blade pitch angle
280 125 0,58
0,54 0,44
250 112 0,56 45°
0,52
Total pressure increase ⌬ pt [Pa] →
Total pressure increase ⌬ pt [Pa] →
224
BVAXO
100
pd
0,52
200 35° Blade pitch angle 90
40°
180 80
0,48
160 37,5°
32,5° 71
140 63
25° 30° 35°
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
V̇ [m3/h] → V̇ [m3/h] →
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
V̇ [m3/s] → V̇ [m3/s] →
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
c [m/s] →
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
c [m/s] →
16
20
25
31,5
40
50
63
80
100
125
160
200
250
pd [Pa] →
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
pd [Pa] →
Shaft power input requirement:
Shaft power input requirement:
112 100
=
=
110 98
V [m3/h] · ⌬pt [Pa]
V [m3/h] · ⌬pt [Pa]
108 35°
· 1000 · 3600
· 1000 · 3600
96
106 37,5° 94
104 50° 92
102 45° 90
35° 100 40°
32,5° 88
·
·
30° 98 86
Pw [kW] =
Pw [kW] =
96
Lw [dB]
84
Lw [dB]
94 82
25° 92 80
* Ai fl di i D( i l ) Pl i i f Ai fl di i S( i i l ) Vl dd d d fi ( ) S( )
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
DIRECT DRIVE WITHOUT GUIDE VANES
SERIES BVAXO These fans are available with the indicated blade pitch only.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN Subsequent pitch variations are not possible. 058
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 76 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 42 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1003 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1124 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 0,79 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 1,0 m2
500
BVAXO 12/1000/D - n = 1450 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
BVAXO 12/1120/D - n = 740 rpm
These fans are available only with the indicated blade pitch. Subsequent pitch variations are not possible.
224
450 200
400 = 180
pd
0,58
=
355 50° Blade pitch angle
160 0,56
315 140
280 125 0,53
45°
0,54
250 112 0,51
0,52
Total pressure increase ⌬ pt [Pa] →
0,49
40°
200 35° Blade pitch angle 90
180 80
0,48 0,47 37,5°
160 71
32,5°
140 63
35°
25° 30° 30° 32,5°
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
V̇ [m3/h] → V̇ [m3/h] →
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
V̇ [m3/s] → V̇ [m3/s] →
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
c [m/s] →
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
c [m/s] →
16
20
25
31,5
40
50
63
80
100
125
160
200
250
pd [Pa] →
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
pd [Pa] →
Shaft power input requirement:
112 105
=
110 103
V [m3/h] · ⌬pt [Pa]
· 1000 · 3600
50°
106 40° 99
104 97
102 35°
35° 30° 95
100 45°
32,5° 93
·
30° 98 91
Pw [kW] =
Pw [kW] =
96 37,5° 89
Lw [dB]
Lw [dB]
94 87
25° 92 32,5°
85
V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 57 m/s Moment of inertia I = kg m2 V̇ = Volume flow [m3/h] bzw. [m3/s] Tip speed u2 = 84 m/s Moment of inertia I = kg m2
pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1124 mm pd = Dynamic pressure [Pa] or x 0,1 [kp/m2] Temperature t = 20°C ␦ Casing diameter d.i.L. = 1124 mm
c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 1,0 m2 c = Flow velocity [m/s] Density = 1,2 kg/m3 Outlet cross section A2 = 1,0 m2
355 710
pd
315 630
= 50°
pd
180 355
0,46 40°
160 0,53 40° 315 0,48
0,50
140 280 37,5°
37,5°
125 250
0,44
112 224 35°
0,45 35°
25° 30° 32,5° 25° 30° 32,5°
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
V̇ [m3/h] → V̇ [m3/h] →
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
V̇ [m3/s] → V̇ [m3/s] →
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
c [m/s] → c [m/s] →
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
31,5
40
50
63
80
100
125
160
200
250
315
400
500
pd [Pa] → pd [Pa] →
Shaft power input requirement:
106 117
=
· 1000 · 3600
37,5°
100 32,5° 111
32,5° 98 109
25° 96 25° 40° 107
40°
35° 94 105
·
92 103
Pw [kW] =
35°
Pw [kW] =
30° 30°
90 101
Lw [dB]
Lw [dB]
88 99
86 97
* rounded to standard values For maximum motor sizes please see dimension pages
– 059 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Surface protection:
Polyester powder coating, colour: RAL 7030
or as of nominal size 1120: with full paint finish, colour: RAL7030
or Hot-dip galvanized
Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Specifications:
Volume flow m3/h
Temperature / humidity 0
C/ %R.H.
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total sound power level Lw dB
Efficiency %
Power input requirement kW
Three-phase motor:
BVAXO
single-speed
or Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Current consumption A
Voltage V
Frequency Hz
Protection Class (IP)
Type B/V
Size
Carryover
Type: BVAXO..........M-D
– 060 –
Unit price Total
Item
Qty. Description
No.
2 2
Options:
• Galvanised fan
• Fan with special coating
• Extension casing without inspection hatch
• Inspection hatch
• Bellmouth inlet with flange
• Wire guard on bellmouth side
• Wire guard on extension casing (motor side)
• Flexible connector, inlet side*
• Flexible connector, outlet side*
• Matching flange inlet side*
• Matching flange outlet side*
• Angular wall ring with brackets*
• Set of mounting feet (2 pcs.)*
• Set of spring-type antivibration mounts*
• Brackets for vertical fan installation
• Diffuser without interior core*
• exhaust pipe with protection grid*
• duct with self-activating damper*
Note:
* Loosely supplied
AXIAL SMOKE EXHAUST FANS
SERIES BVAXN 12/56
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C - 120 MIN 061
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
zxd
i.d.
L øD
No cooling-fan required
Weight
Size1) i.d. (kg) Motor size - Type
Size without Flange dia. Ø 2) - Shaft dia. Ø
motor
BVAXN 12/56
3)
200 - B 5 225 - B 5 250 - B 5 280 75 315 80
400 - 55 450 - 60 550 - 65 B3/V1/V3 B3/V1/V3
200 - B 5 225 - B 5
3) 400 - 55 450 - 60
200 - B 5 280 75 315 80
550 - 65 B3/V1/V3 B3/V1/V3
For vibration-damped installation an Extension Special flanges may be = For vibration-damped installation Dimensions mm
Extension casing may be required with fans up needed with certain sizes. two extension casings should be
to size 1250 provided.
3) with steel impeller 8/56
Dimensional and design
changes reserved.
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
AXIAL SMOKE EXHAUST FANS
SERIES BVAXN 12/56
MAIN DIMENSIONS ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 062
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Wire Guard Bell mouth Mounting feet Mounting feet for fans with extension casing or
Inlet side inlet R1 types
i.d1
i.d2
i.d2
355 501 362 69 270 221 191 386 356 330 270 5 x 9,5 360 395 425 8 x 9,5 80 50
400 562 403 78 300 248 218 436 406 370 300 5 x 9,5 403 438 468 12 x 9,5 80 50
450 631 424 87 335 260 230 460 430 410 330 5 x 9,5 452 487 517 12 x 9,5 80 50
500 708 509 98 375 285 255 510 480 460 380 5 x 9,5 506 541 571 12 x 9,5 80 50
560 794 571 109 420 317 277 559 519 510 430 5 x 11,5 568 605 643 16 x 11,5 100 70
630 875 640 95 470 361 321 647 607 550 470 5 x 11,5 637 674 712 16 x 11,5 100 70
710 972 717 103 525 380 340 685 645 620 530 5 x 11,5 714 751 785 16 x 11,5 100 70
800 1081 801 115 585 425 385 775 735 730 640 5 x 11,5 800 837 875 24 x 11,5 100 70
900 1214 898 130 655 452 412 825 781 730 640 5 x 11,5 897 934 972 24 x 11,5 100 70
1000 1351 1009 145 730 512 466 927 881 830 740 5 x 14 1006 1043 1081 24 x 11,5 100 70
1120 1470 1130 160 760 547 501 997 951 920 820 5 x 14 1133 1174 1214 24 x 11,5 110 90
1250 1677 1263 185 855 597 551 1097 1051 1030 930 5 x 14 1270 1311 1351 24 x 11,5 110 90
a = Casing length + 87
1400 1870 1417 210 930 a1 = –”– +41 1140 1040 5 x 14 1424 1465 1505 24 x 11,5 130 100
1600 2087 1587 210 1020 a = Casing length + 92 1350 1230 5 x 18 1596 1637 1677 32 x 11,5 130 100
1) Connecting dimensions in 2) Height under load will be * all accessories, except duct Dimensions in mm
accordance with DIN 24 154 – communicated upon specification feet and duct extension, are
Series 3 (value is calculated individually for packed separately
Dimensional and design
each purchase order).
changes reserved.
AXIAL SMOKE EXHAUST FANS
SERIES BVAXN 12/56
MAIN DIMENSIONS ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300/400°C – 120 MIN 063
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
i.d.
i.d2
1
welded
Øk
wire guard
zxd L3
450 603 651 68 12 – 487 – 12 x 9,5 – – – – – – 290 70 200 350 200 BVAXN 12/56
500 657 705 68 12 504 541 571 12 x 9,5 634 282 674 712 16 x 11,5 600 280 60 225 390 200
560 783 831 90 14 565 605 643 16 x 11,5 711 315 751 789 16 x 11,5 670 330 70 242 430 200
630 852 900 90 14 634 674 712 16 x 11,5 797 355 837 875 24 x 11,5 750 330 70 286 465 200
710 929 977 90 14 711 751 789 16 x 11,5 894 397 934 972 24 x 11,5 850 350 70 305 505 200
800 1015 1063 90 14 797 837 875 24 x 11,5 1003 446 1043 1081 24 x 11,5 950 520 200 350 550 200
900 1112 1160 90 14 894 934 972 24 x 11,5 1124 502 1174 1254 24 x 11,5 1060 585 225 373 620 200
1000 1221 1269 90 14 1003 1043 1081 24 x 11,5 1261 562 1311 1391 24 x 11,5 1200 640 240 415 690 200
1120 1374 1434 100 18 1124 1174 1254 24 x 11,5 1415 630 1465 1545 24 x 11,5 1340 730 250 450 820 300
1250 1511 1571 100 18 1261 1311 1391 24 x 11,5 1587 710 1637 1717 32 x 11,5 1510 810 250 500 950 300
1400 1665 1725 100 18 1415 1465 1545 24 x 11,5 1780 789 1830 1910 32 x 11,5 1690
on request
1600 1837 1897 100 18 1587 1637 1717 32 x 11,5 1997 888 2047 2167 32 x 11,5 1900
400 6 12 16 21 23 29 22 18
450 450 620 487 250 930 12 x M 8 56
1000 3 8 12 15 17 14 12 8
1000 1003 1255 1043 560 1430 24 x M 8 167
224
180
140
static pressure loss ⌬ ps [Pa] ➞
5
35
112
ia
00
50
0
0
0
20
0
56
63
71
80
90
45
40
50
ld
90
10
12
11
ina
Ø
Ø
Ø
Ø
Ø
71
m
2500
3150
4000
5000
6300
8000
10000
12500
16000
20000
25000
31500
40000
50000
63000
80000
100000
125000
Description:
shell-design, easy dismanteling, re-
usable. For acoustic insulation and/or
reduction of thermal emission from
the fan casing.
The design of this insulation - compa-
red to some ohter types - allows a
more space saving installation with
improved accessibility as well as con-
siderably easier testing and mainten-
ance of the fan.
The Insulation consists of:
A certain number of shells acc. to fan
length, split into upper and lower
shell, made of galvanized steel sheet
with adjustable also galvanized ten-
sioners. Galvanized steel sheets for
connecting the shells in the vicinity of
the fan’s mounting feet as well as in-
sulated connections to flexible
connectors or ducts. Axial Fan BVZAXN 12/56/1000 with acoustic insulation
Insulating material made of mineral
wool with wire gauze on one side,
thickness 80 mm and 120 mm respet-
cively, not inflammable class A1 as
per DIN 4102 T4, specific density 60-
80 kg/m3. These mats are fixed to the
shells.
· Q·L
·
700 V· = [m3/h]
Insulation value [De] 0,336 · (Troom - Tfresh air)
Insulation value [De] 600 400°C
dB (A) weighted
500
300°C
fD [Hz] 500 250 125 400
size 300 600°C 200°C
35 35 36
315-560
size 200 400°C
37 38 37
630-1600 100 300°C
200°C
0
315
355
400
450
500
560
630
710
800
900
1000
1120
1250
1400
1600
Type D
D2
L4 Insulation
Size L3 A2 A3 b d
L3
355 495 631 679 68 12
Size D2 L2 L3 L4 Size D2 L2 L3 L4
355 525 330 495 660 710 960 610 915 1220
400 570 376 564 752 800 1050 700 1050 1400
450 620 400 600 800 900 1145 746 1119 1492
500 675 450 675 900 1000 1255 830 1245 1660
560 735 484 726 968 1120 1375 900 1350 1800
630 885 572 858 1144 1250 1515 1000 1500 2000
Impeller of
axial fan
Flexible
Connector
200
Connecting piece
230 Tensioner Insulated duct
Flexible sleeve Adhesive tape (customer-
supplied)
Impeller of
axial fan
Insulation
(loosley
supplied)
Flexible
Connector
200
AXIAL SMOKE EXHAUST FANS
BVAXN 12/56 SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 068
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Acoustic level Starting from this value, the A-weigh- ning, respectively. The values given
ted acoustic power level LWA and the were taken from measurements as
relative acoustic power level LWrel. per EN 25136 (formerly DIN 45 635,
The total acoustic power level Part 9) duct testing method.
can be determined using the tables
LW.Vent. (in dB) of an axial smoke ex- below. These values are available as
haust fan can be obtained directly the acoustic power emitted into the
from the characteristic data sheets for duct and as the acoustic power emit-
each operating point. ted from the fan inlet or outlet ope-
1. Acousting power level emitted into the duct Axial Smoke Exhaust Fan BVAXN
The level of acoustic power an axial smoke exhaust fan
Portion 1.2 at mid-octave frequency [Hz]
emits into the ducting is used for calculating the sound power z·n
fD = –––– Portion 1.1
60
characteristics of downstream systems, e.g., silencers. 63 125 250 500 1000 2000 4000 8000
The levels are calculated as follows:
500 2 13 10 8 6 6 12 15 16
Lwvent. [dB] = total acoustic power emitted by the fan, 250 5 10 8 5 5 11 14 16 18
(please see respective characteristic curve
sheets) 125 7 7 5 5 11 14 16 18 22
63 10 4 4 10 13 15 17 21 25
LwA vent. [dB] = A-weighted acoustic power level, according
to the equation 31,5 11 3 9 12 13 15 20 24 28
Blade frequency of the fan ist calculated from the number of bla-
des z and the fan speed n [rpm].
z · n [s-1]
fD = ––––––
60
Lwvent.
LwAvent.
Amount linear-level
Lwrel.vent.
Amount A
fD Note:
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above
Hz 63 125 250 500 1000 2000 4000 8000 spreadsheets.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 200°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 069
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
355 1500 1,1 2,8 90 B14 160 500 1000/500 0,48/0,08 1,6/0,58 90 B5 200
3000 1,5 3,25 90 B14 160 1500/750 1,0/0,25 2,4/1,0 90 B5 200
2,2 4,6 90 B14 160 1,4/0,35 3,3/1,35 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B14 160 1500/1000 1,1/0,37 2,8/1,35 90 B5 200
3000/1500 1,5/0,37 3,7/1,0 90 B14 160 1,6/0,6 3,9/1,8 100 B5 250
3000/1500 6,0/1,5 13,3/3,2 132 B5 250
400 1500 1,1 2,8 90 B5 200 7,8/2,0 16,2/4,1 132 B5 250
3000 1,5 3,25 90 B5 200
2,2 4,6 90 B5 200 560 1000 0,75 2,2 90 B5 200
3,0 6,7 100 B14 200 1500 1,1 2,8 90 B5 200
4,0 8,3 112 B14 200 1,5 3,5 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B5 200 2,2 5,5 100 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B5 200 3,0 7,1 100 B5 250
2,2/0,48 4,6/1,15 90 B5 200 1000/500 0,8/0,15 2,3/0,9 90 B5 200
3,0/0,75 6,7/1,7 100 B14 200 1500/750 1,4/0,35 3,3/1,35 90 B5 200
4,1/1,0 8,8/2,1 112 B14 200 2,5/0,6 5,6/2,2 100 B5 250
3,8/1,0 8,1/3,4 112 B5 250
450 1500 1,1 2,8 90 B5 200 1500/1000 1,1/0,37 2,8/1,35 90 B5 200
3000 3,0 6,7 100 B14 200 1,6/0,6 3,9/1,8 100 B5 250
4,0 8,3 112 B14 200 3,0/1,0 6,3/3,0 112 B5 250
5,5 11 112 B14 200
7,5 14,6 112 B14 200 630 750 0,55 1,8 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B5 200 1000 0,75 2,2 90 B5 200
1500/1000 1,1/0,37 2,8/1,35 90 B5 200 1,1 3,15 90 B5 200
3000/1500 3,0/0,75 6,7/1,7 100 B14 200 1,5 3,9 100 B5 250
4,1/1,0 8,8/2,1 112 B14 200 1500 1,5 3,5 90 B5 200
2,2 5,5 100 B5 250
500 1500 1,1 2,8 90 B5 200 3,0 7,1 100 B5 250
1,5 3,5 90 B5 200 4,0 8,6 112 B5 250 BVAXN 12/56
3000 4,0 8,3 112 B5 250 5,5 11,4 132 B5 250
5,5 11 132 B5 250 1000/500 0,8/0,15 2,3/0,9 90 B5 200
7,5 14,6 132 B5 250 1,2/0,22 3,1/1,15 100 B5 250
11 20,5 132 B5 250 1500/750 2,5/0,6 5,6/2,2 100 B5 250
3,8/1,0 8,1/3,4 112 B5 250
5,5/1,4 11,4/4,3 132 B5 250
1500/1000 2,2/0,75 5,3/2,3 100 B5 250
3,0/1,0 6,3/3,0 112 B5 250
6,0/2,0 12,5/5,4 132 B5 250
710 750 0,75 2,2 100 B5 250 800 1500/1000 6,0/2,0 12,5/5,4 132 B5 250
1,1 3,15 100 B5 250 8,5/3,0 17,9/17,6 160 B5 350
1000 1,1 3,15 90 B5 200 12/3,50 24/9,5 160 B5 350
1,5 3,9 100 B5 250 14/4,8 30/12 180 B5 350
2,2 5,4 112 B5 250 18/16,0 36/14 180 B5 350
3,0 7,4 132 B5 250
1500 3,0 7,1 100 B5 250 900 750 1,1 3,15 100 B5 250
4,0 8,6 112 B5 250 1,5 5,15 112 B5 250
5,5 11,4 132 B5 250 2,2 5,4 132 B5 250
7,5 15,4 132 B5 250 3,0 7,6 132 B5 250
11 22 160 B5 350 4,0 9,3 160 B5 350
1000/500 1,2/0,22 3,1/1,15 100 B5 250 1000 3,0 7,4 132 B5 250
1,85/0,33 4,6/1,6 112 B5 250 4,0 9,2 132 B5 250
3,3/0,75 9,3/3,6 132 B5 250 5,5 12,7 132 B5 250
1500/750 3,8/1,0 8,1/3,4 112 B5 250 7,5 15,7 160 B5 350
5,5/1.4 11,4/4,3 132 B5 250 11 22 160 B5 350
7,0/1,7 15,2/5,1 132 B5 250 1500 11 22 160 B5 350
11/3,0 24/9,5 160 B5 350 15 29,5 160 B5 350
1500/1000 4,5/1,5 9,5/3,8 132 B5 250 18,5 36 180 B5 350
6,0/2,0 12,5/5,4 132 B5 250 22 43 180 B5 350
8,5/3,0 17,9/7,6 160 B5 350 30 52 200 B5 350
12/3,5 24/9,5 160 B5 350 1000/500 3,3/0,75 9,3/3,6 132 B5 250
4,4/1,1 11/4,4 132 B5 250
800 750 1,1 3,15 100 B5 250 6,3/1,5 15,7/5,4 160 B5 350
1,5 5,15 112 B5 250 8,8/2,2 20,5/7,0 160 B5 350
2,2 5,4 132 B5 250 1500/750 11/3,0 24/9,5 160 B5 350
1000 2,2 5,4 112 B5 250 14/3,5 30,5/11,4 160 B5 350
3,0 7,4 132 B5 250 16/4,0 32,5/11,9 180 B5 350
4,0 9,2 132 B5 250 20/5,5 39/16,2 180 B5 350
5,5 12,7 132 B5 250 28/7,0 52/16,2 200 B5 350
1500 5,5 11,4 132 B5 250 1500/1000 12/3,5 24/9,5 160 B5 350
7,5 15,4 132 B5 250 14/4,8 30/12 180 B5 350
11 22 160 B5 350 18/6,0 36/14 180 B5 350
15 29,5 160 B5 350 20/7,0 41/16,2 200 B5 350
18,5 36 180 B5 350 25/9,0 47/18,5 200 B5 350
1000/500 2,6/0,5 7,1/2,8 132 B5 250 31/10 60/21,5 225 B5 350
3,3/0,75 9,3/3,6 132 B5 250
4,4/1,0 11/4,40 132 B5 250
1500/750 5,5/1,4 11,4/4,3 132 B5 250
7,0/1,7 15,2/5,1 132 B5 250
11/3,0 24/9,5 160 B5 350
14/3,5 30,5/11,4 160 B5 350
16/4,0 32,5/11,9 180 B5 350
1000 750 2,2 5,4 132 B5 250 1120 1000/500 8,8/2,2 20,5/7,0 160 B5 350
3,0 7,6 132 B5 250 12,5/3,0 32,5/11 180 B5 350
4,0 9,3 160 B5 350 15,5/3,3 34/11 200 B5 400
5,5 11,4 160 B5 350 18,5/4,4 40/13,3 200 B5 400
7,5 16,1 160 B5 350 22/5,5 44,5/16 225 B5 450
1000 5,5 12,7 132 B5 350 27/6,6 52/20 225 B5 450
7,5 15,7 160 B5 350
11 22 160 B5 350 1250 750 5,5 11,4 160 B5 350
15 29,5 180 B5 350 7,5 16,1 160 B5 350
1500 15 29,5 160 B5 350 11 23,5 180 B5 350
18,5 36 180 B5 350 15 31 200 B5 400
22 43 180 B5 350 18,5 37 225 B5 450
30 52 200 B5 350 22 44,5 225 B5 450
37 66 225 B5 450 1000 15 29,5 180 B5 350
45 82 225 B5 450 20 40 200 B5 400
1000/500 4,4/1,0 11/4,4 132 B5 250 22 43 200 B5 400
6,3/1,5 15,7/5,4 160 B5 350 30 57 225 B5 450
8,8/2,2 20,5/7,0 160 B5 350 37 67 225 B5 450
12,5/3,0 32,5/11 180 B5 350 1000/500 15,5/3,0 34/11,0 200 B5 400
22/5,5 44,5/16 225 B5 450 18,5/4,4 40/13,3 200 B5 400
1500/750 16/4,0 32,5/11,9 180 B5 350 22/5,5 44,5/16 225 B5 450
20/5,5 39/16,2 180 B5 350 27/6,6 52/20 225 B5 450
28/7,0 52/16,2 200 B5 350
32/8,0 60/19 225 B5 450 1400 750 11 23,5 180 B5 350
37/10 69/24,5 225 B5 450 15 31 200 B5 450
1500/1000 18/6,0 36/14 180 B5 350 18,5 37 225 B5 450
20/7,0 41/16,2 200 B5 350 22 44,5 225 B5 450
25/9,0 47/18,5 200 B5 350 1000 30 57 225 B5 450
31/10 60/21,5 225 B5 450 37 67 225 B5 450 BVAXN 12/56
1000/500 27/6,6 52/20 225 B5 450
1120 750 4,0 9,3 160 B5 350
5,5 11,4 160 B5 350 1600 750 22 44,5 225 B5 450
7,5 16,1 160 B5 350
11 23,5 180 B5 350
15 31 200 B5 400
1000 7,5 15,7 160 B5 350
11 22 160 B5 350
15 29,5 180 B5 350
20 40 200 B5 400
22 43 200 B5 400
30 57 225 B5 450
355 1500 1,1 2,8 90 B14 160 560 1000 0,75 2,2 90 B5 200
3000 1,5 3,25 90 B14 160 1500 1,1 2,8 90 B5 200
2,2 4,6 90 B14 160 1,5 3,5 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B14 160 2,2 5,5 100 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B14 160 3,0 7,1 100 B5 250
1000/500 0,8/0,15 2,3/0,9 90 B5 200
400 1500 1,1 2,8 90 B5 200 1500/750 1,4/0,35 3,3/1,35 90 B5 200
3000 1,5 3,25 90 B5 200 2,5/0,65 5,6/2,2 100 B5 250
2,2 4,6 90 B5 200 3,8/1,0 8,1/3,4 112 B5 250
3,0 6,7 100 B14 200 1500/1000 1,1/0,37 2,8/1,35 90 B5 200
4,0 8,3 112 B14 200 1,6/0,6 3,9/1,8 100 B5 250
1500/750 1,0/0,25 2,4/1,0 90 B5 200 3,0/1,0 6,3/3,0 112 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B5 200
2,2/0,48 4,6/1,15 90 B5 200 630 750 0,55 1,8 90 B5 200
3,0/0,75 6,7/1,7 100 B14 200 1000 0,75 2,2 90 B5 200
4,1/1,0 8,8/2,1 112 B14 200 1,1 3,15 90 B5 200
1,5 3,9 100 B5 250
450 1500 1,1 2,8 90 B5 200 1500 1,5 3,5 90 B5 200
3000 3,0 6,7 100 B14 200 2,2 5,5 100 B5 250
4,0 8,3 112 B14 200 3,0 7,1 100 B5 250
5,5 11 112 B14 200 4,0 8,6 112 B5 250
7,5 14,6 112 B14 200 5,5 11,4 132 B5 250
1500/750 1,0/0,25 2,4/1,0 90 B5 200 1000/500 0,8/0,15 2,3/0,9 90 B5 200
1500/1000 1,1/0,37 2,8/1,35 90 B5 200 1,2/0,22 3,1/1,15 100 B5 250
3000/1500 3,0/0,75 6,7/1,7 100 B14 200 1500/750 2,5/0,6 5,6/2,2 100 B5 250
4,1/1,0 8,8/2,1 112 B14 200 3,8/1,0 8,1/3,4 112 B5 250
5,5/1,4 11,4/4,3 132 B5 250
500 1500 1,1 2,8 90 B5 200 1500/1000 2,2/0,75 5,3/2,3 100 B5 250
1,5 3,5 90 B5 200 3,0/1,0 6,3/3,0 112 B5 250
3000 4,0 8,3 112 B5 250 6,0 12,5/5,4 132 B5 250
5,5 11 132 B5 250
7,5 14,6 132 B5 250
11 20,5 132 B5 250
1000/500 0,48/0,08 1,6/0,58 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B5 200
1,4/0,35 3,3/1,35 90 B5 200
1500/1000 1,1/0,37 2,8/1,35 90 B5 200
1,6/0,6 3,9/1,8 100 B5 250
3000/1500 6,0/1,5 13,3/3,2 132 B5 250
7,8/2,0 16,2/4,1 132 B5 250
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 073
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
710 750 0,75 2,2 100 B5 250 800 1500/1000 6,0/2,0 12,5/5,4 132 B5 250
1,1 3,15 100 B5 250 8,5/3,0 17,9/7,6 160 B5 350
1000 1,1 3,15 90 B5 200 12/3,5 24/9,5 160 B5 350
1,5 3,9 100 B5 250 14/4,8 30/12 180 B5 350
2,2 5,4 112 B5 250 18/6,0 36/14 180 B5 350
3,0 7,4 132 B5 250
1500 3,0 7,1 100 B5 250 900 750 1,1 3,15 100 B5 250
4,0 8,6 112 B5 250 1,5 5,15 112 B5 250
5,5 11,4 132 B5 250 2,2 5,4 132 B5 250
7,5 15,4 132 B5 250 3,0 7,6 132 B5 250
11 22 160 B5 350 4,0 9,3 160 B5 350
1000/500 1,2/0,22 3,1/1,15 100 B5 250 1000 3,0 7,4 132 B5 250
1,85/0,33 4,6/1,6 112 B5 250 4,0 9,2 132 B5 250
3,3/0,75 9,3/3,6 132 B5 250 5,5 12,7 132 B5 250
1500/750 3,8/1,0 8,1/3,4 112 B5 250 7,5 15,7 160 B5 350
5,5/1,4 11,4/4,3 132 B5 250 11 22 160 B5 350
7,0/1,7 15,2/5,1 132 B5 250 1500 11 22 160 B5 350
11/3,0 24/9,5 160 B5 350 15 29,5 160 B5 350
1500/1000 4,5/1,5 9,5/3,8 132 B5 250 18,5 36 180 B5 350
6,0/2,0 12,5/5,4 132 B5 250 22 43 180 B5 350
8,5/3,0 17,9/7,6 160 B5 350 30 52 200 B5 350
12/3,5 24/9,5 160 B5 350 1000/500 3,3/0,75 9,3/3,6 132 B5 250
4,4/1,1 11/4,4 132 B5 250
800 750 1,1 3,15 100 B15 250 6,3/1,5 15,7/5,4 160 B5 350
1,5 5,15 112 B5 250 8,4/2,2 20,5/7,0 160 B5 350
2,2 5,4 132 B5 250 1500/750 11/3,0 24/9,5 160 B5 350
1000 2,2 5,4 112 B5 250 14/3,5 30,5/11,4 160 B5 350
3,0 7,4 132 B5 250 16/4 32,5/11,9 180 B5 350
4,0 9,2 132 B5 250 20/5,5 39/16,2 180 B5 350 BVAXN 12/56
5,5 12,7 132 B5 250 28/7,0 52/16,2 200 B5 350
1500 5,5 11,4 132 B5 250 1500/1000 12/3,5 24/9,5 160 B5 350
7,5 15,4 132 B5 250 14/4,8 30/12 180 B5 350
11 22 160 B5 350 18/6,0 36/14 180 B5 350
15 29,5 160 B5 350 20/7,0 41/16,2 200 B5 350
18,5 36 180 B5 350 25/9,0 47/18,5 200 B5 350
1000/500 2,6/0,5 7,1/2,8 132 B5 250 33/11 61/24 225 B5 350
3,3/0,75 9,3/3,6 132 B5 250
4,4/1,0 11/4,4 132 B5 250
1500/750 5,5/1,4 11,4/4,3 132 B5 250
7,0/1,7 15,2/5,1 132 B5 250
11/3,0 24/9,5 160 B5 350
14/3,5 30,5/11,4 160 B5 350
16/4,0 32,5/11,9 180 B5 350
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 074
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
1000 750 2,2 5,4 132 B5 250 1120 750 4,0 9,3 160 B5 350
3,0 7,6 132 B5 250 5,5 11,4 160 B5 350
4,0 9,3 160 B5 350 7,5 16,1 160 B5 350
5,5 11,4 160 B5 350 11 23,5 180 B5 350
7,5 16,1 160 B5 350 15 31 200 B5 400
1000 5,5 12,7 132 B5 250 1000 7,5 15,7 160 B5 350
7,5 15,7 160 B5 350 11 22 160 B5 350
11 22 160 B5 350 15 29,5 180 B5 350
15 29,5 180 B5 350 20 40 200 B5 400
1500 15 29,5 160 B5 350 22 43 200 B5 400
18,5 36 180 B5 350 30 57 225 B5 450
22 43 180 B5 350 1500 30 52 200 B5 400
30 52 200 B5 350 37 66 225 B5 450
37 66 225 B5 450 45 82 225 B5 450
45 82 225 B5 450 55 (L) 97 250 B5 550
1000/500 4,4/1,0 11/4,4 132 B5 250 75 (L) 132 280 B5 550
6,3/1,5 15,7/5,4 160 B5 350 90 (L) 157 280 B5 550
8,8/2,2 20,5/7,0 160 B5 350 1000/500 7,5/1,85 19/6,7 160 B5 350
12,5/3,0 32,5/11 180 B5 350 8,8/2,2 20,5/7,0 160 B5 350
15,5/3,3 34/11 200 B5 350 12,5/3,0 32,5/11 180 B5 350
1500/750 16/4,0 32,5/11,9 180 B5 350 15,5/3,3 34/11 200 B5 400
20/5,5 39/16,2 180 B5 350 18,5/4,4 40/13,3 200 B5 400
28/7,0 52/16,2 200 B5 350 22/5,5 44,5/16 225 B5 450
32/8,0 60/19 225 B5 450 27/6,6 52/20 225 B5 450
37/10 69/24,5 225 B5 450 1500/750 32/8,0 60/19 225 B5 450
1500/1000 18/6,0 36/14 180 B5 350 37/10 69/24,5 225 B5 450
20/7,0 41/16,2 200 B5 450 39/9,5 (L) 72/21 225 B5 450
25/9,0 47/18,5 200 B5 350 44/11 (L) 78/24 225 B5 450
33/11 61/24 225 B5 450 49/11 (L) 84/23 250 B5 550
68/17 (L) 125/43,5 280 B5 550
80/20 (L) 140/48 280 B5 550
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 300°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 075
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
1250 750 5,5 11,4 160 B5 350 1400 1000/500 27/6,6 52/20 225 B5 450
7,5 16,1 160 B5 350 30/7,0 58/19 250 B5 550
11 23,5 180 B5 350 40/8,0 (L) 74/24 280 B5 550
15 31 200 B5 400 48/9,5 (L) 88/28 280 B5 550
18,5 37 225 B5 450 60/12 (L) 106/22 315 B5 660
22 44,5 225 B5 450 70/14 (L) 125/33 315 B5 660
1000 15 29,5 180 B5 350 85/16 (L) 150/37 315 B5 660
20 40 200 B5 400 105/20 (L) 185/47 315 B5 660
22 43 200 B5 400
30 57 225 B5 450
37 67 225 B5 450
1500 45 82 225 B5 450
55 (L) 97 250 B5 550
75 (L) 132 280 B5 550
90 (L) 157 280 B5 550
110 (L) 200 315
132 (L) 240 315
160 (L) 285 315
1000/500 15,5/3,3 34/11 200 B5 400
18,5/4,4 40/13,3 200 B5 400
22/5,5 44,5/16 225 B5 450
27/6,6 52/20 225 B5 450
30/7 (L) 58/19 250 B5 550
1500/750 44/11 (L) 78/24 225 B5 450
49/11 (L) 84/23 250 B5 550
68/17 (L) 125/43,5 280 B5 550
80/20 (L) 140/48 280 B5 550
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 400°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 076
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
355 1500 1,1 2,85 90 B14 160 710 750 1,1 3,5 112 B5 250
3000 1,5 3,4 90 B14 160 1000 1,1 3,6 100 B5 250
1,5 4,2 112 B5 250
400 1500 1,1 2,85 90 B5 200 2,2 5,2 132 B5 250
3000 1,5 3,4 90 B5 200 3,0 7,5 132 B5 250
2,2 4,8 100 B14 200 1500 3,0 7,0 112 B5 250
3,0 6,2 112 B14 160 4,0 9,0 132 B5 250
3000/1500 3,0/0,8 7,0/2,0 112 B14 160 5,5 12 132 B5 250
7,5 14,5 160 B5 350
450 1500 1,1 2,85 90 B5 200 11 23 160 B5 350
3000 3,0 6,2 112 B14 200 1000/500 2,0/0,33 5,0/2,5 132 B5 250
3,2/0,7 7,0/4,0 132 B5 250
500 1500 1,5 4,0 100 B5 250 1500/750 3,7/0,9 9,2/3,8 132 B5 250
3000 4,0 8,5 132 B5 250 5,0/1,3 11,5/4,5 132 B5 250
5,5 11 132 B5 250 10/3,0 25/10,5 160 B5 350
1500/1000 4,2/1,25 10/3,2 132 B5 250
7,5 14,5 160 B14 250
7,5/2,2 17/6,0 160 B5 350
1500/750 2,5/0,55 6,5/2,5 112 B5 250
12/3,5 28/11 160 B5 350
1500/1000 2,4/0,75 6,8/2,8 112 B5 250
3000/1500 3,0/0,8 7,0/2,0 112 B5 250
6,0/1,6 13/3,5 132 B5 250 800 750 1,1 3,5 112 B5 250
1,5 4,2 132 B5 250
560 1500 1,5 4,0 100 B5 250 2,2 6,0 132 B5 250
2,2 6,0 100 B5 250 1000 2,2 5,2 132 B5 250
3,0 7,0 112 B5 250 3,0 7,5 132 B5 250
1500/750 2,5/0,55 6,5/2,5 112 B5 250 4,0 9,4 132 B5 250
3,7/0,9 9,2/3,8 132 B5 250 7,5 16,5 160 B5 350
1500/1000 3,0/0,9 7,0/2,5 132 B5 250 1500 5,5 12 132 B5 250
7,5 14,5 160 B5 350
1000/500 2,0/0,33 5,0/2,5 132 B5 250 1500/750 5,0/1,3 11,5/4,5 132 B5 250
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 12/56 400°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 077
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
900 750 1,1 3,5 112 B5 250 1000 1500/750 16/4,0 33/15 180 B5 350
1,5 4,2 132 B5 250 20/5,0 42/16 180 B5 350
2,2 6,0 132 B5 250 28/7,0 56/16,5 200 B5 350
4,0 10 160 B5 350 33/8,0 59/17,4 225 B5 450
1000 3,0 7,5 132 B5 250 39/9,5 76/25 225 B5 450
4,0 9,4 132 B5 250 1500/1000 16,5/5,5 32/11,8 180 B5 350
7,5 16,5 160 B5 350 31/10 60/21 225 B5 450
11 32,5 160 B5 350
1500 11 23 160 B5 350 1120 750 4,0 10 160 B5 350
15 31 160 B5 350 5,5 14,5 160 B5 350
18,5 37 180 B5 350 7,5 19 160 B5 350
22 43 180 B5 350 11 26 180 B5 350
30 57 200 B5 350 15 35 200 B5 400
1000/500 3,2/0,7 7,0/4,0 132 B5 250 1000 7,5 16,5 160 B5 350
6,2/1,3 15/4,2 160 B5 350 11 23,5 160 B5 350
8,4/1,8 18,5/5,1 160 B5 350 15 33 180 B5 350
1500/750 10/3,0 25/10,5 160 B5 350 22 48 200 B5 400
13/3,5 32/12,5 160 B5 350 1000/500 6,2/1,3 15/4,2 160 B5 350
16/4,0 33/15 180 B5 350 8,4/1,8 18,5/5,1 160 B5 350
20/5,0 42/16 180 B5 350 12,5/3,0 26/8,0 180 B5 350
28/7,0 56/16,5 200 B5 350 20/4,5 40/14 200 B5 400
1500/1000 12/3,5 28/11 160 B5 350 22/5,0 45/14,5 225 B5 450
16,5/5,5 32/11,8 180 B5 350 27/6,0 54/19 225 B5 450
31/10 60/21 225 B5 350
1250 750 5,5 14,5 160 B5 350
1000 750 2,2 6,0 132 B5 250 7,5 19 160 B5 350
4,0 10 160 B5 350 11 26 180 B5 350
5,5 14,5 160 B5 350 15 35 200 B5 400
7,5 19 160 B5 350 18,5 42 225 B5 450 BVAXN 12/56
1000 7,5 16,5 160 B5 350 1000 15 33 180 B5 350
11 23,5 160 B5 350 22 48 200 B5 400
15 33 180 B5 350 30 61 225 B5 450
1500 15 31 160 B5 350 1000/500 20/4,5 40/14 200 B5 400
18,5 37 180 B5 350 22/5,0 45/14,5 225 B5 450
22 43 180 B5 350 27/6,0 54/19 225 B5 450
30 57 200 B5 350
37 69 225 B5 450 1400 750 11 26 180 B5 350
45 86 225 B5 450 15 35 200 B5 400
1000/500 6,2/1,3 15/4,2 160 B5 350 18,5 42 225 B5 450
8,4/1,8 18,5/5,1 160 B5 350 22 47,5 225 B5 450
12,5/3,0 26/8,0 180 B5 350 1000 30 61 225 B5 450
20/4,5 40/14 200 B5 350 1000/500 27/6,6 54/19 225 B5 450
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 078
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
140
BVAXN 12/56/355/D – n = 1360 rpm 800
BVAXN 12/56/355/D – n = 2820 rpm
125 0,55 = 0,46 710 0,79 = 0,70
0,52 0,43 0,76 0,67
112 630
pd
pd
0,42 0,66
90 0,32 500 0,56
25° 25°
pd
pd
➞➞
➞➞
80 450
(Pa)
(Pa)
35° 35°
pressure increase 6⌬ptpt[Pa]
TotalTotaldruckerhöhung
56 315
· 15° 0,23 · 15° 0,47
50 280
25° 25°
45 250
20° 0,37 20°
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15°
900
1 000
1 120
1 250
1 400
1 600
1 800
2 000
2 240
2 500
2 800
3 150
3 550
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
0,25
0,28
3,15 0,315
3,55 0,355
0,4
0,45
0,5
0,56
0,63
0,71
0,8
0,9
1,0
Pw = = [kW] Pw = = [kW]
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
[m3/s] ➞ [m3/s] ➞
2,5
2,8
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
c [m/s] ➞ c [m/s] ➞
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
25
31,5
40
50
63
80
100
125
160
200
250
315
400
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with duct 2.5 D
mit Rohrleitung 2,5 D pd [Pa] ➞
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
c [m/s] ➞ c [m/s] ➞
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
50
63
80
100
125
160
200
250
315
400
500
630
800
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
87
Gesamt-Schalleistungspegel Lw [dB]
101
w [dB]
acoustic powerLlevel
acoustic power level
=
=
86 5° 100
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
5° 85
· 1000 · 3600
99
· 1000 · 3600
an der
an der
Gesamt-Schalleistungspegel
power input
power input
15° 84 15° 98
10° 10°
83 97
35°
Leistungsbedarf
0°
Leistungsbedarf
82 0° 96
requirement
35°
requirement
30° 81 30° 95
Max. mögliche 25° Max. mögliche 25°
80 94
Motorbau- Motorbau-
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
20° 79 93
Welle:
Shaft
20°
Welle:
Shaft
Total
Total
Maßblätter 78 Maßblätter 92
77 91
200
BVAXN 12/56/400/D – n = 1360 rpm 1000
BVAXN 12/56/400/D – n = 2895 rpm
0,83 = 0,74
180 0,66 = 0,57 900 0,75 0,71
0,63 0,54
160 800 0,70
0,66
pd
0,58
140 0,49 710 0,60
pd
0,50
0,53
0,43
125 630 25°
pd
25°
pd
➞➞
➞➞
(Pa)
35°
20°
0,44
[Pa]
[Pa]
pressure increase6⌬ptpt
20°
30°
90 450
30°
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
80
15° 0,51
400
· 15° 0,34 · 25°
71 25° 355
63 315 0,41
1 600
1 800
2 000
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
0,4
0,45
0,5
0,56
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
[m3/s] ➞ [m3/s] ➞
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
c [m/s] ➞ c [m/s] ➞
5,0
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
31,5
40
50
63
80
100
125
160
200
250
315
400
500
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
c [m/s] ➞ c [m/s] ➞
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
63
80
100
125
160
200
250
315
400
500
630
800
1 000
103
w [dB]
acoustic powerLlevel
=
5° 88 102
V̇[m3/h] · ⌬pt [Pa]
5° 15°
· 1000 · 3600
87 10° 101
· 1000 · 3600
an der
an der
Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
power input
power input
0°
Leistungsbedarf
35° 84 25° 98
requirement
requirement
30° 83
Max. mögliche 25° 97
82 Max. mögliche 20°
Motorbau- 96
20° Motorbau-
Lw (dB)
Pw [kW]=
Lw (dB)
Pw [kW]=
81
Welle:
Shaft
95
Welle:
Shaft
Maßblätter 80 94
Maßblätter
79 93
*Luftrichtung
* rounded toDstandard
(über Motor drückend) – Luftrichtung S (über Motor saugend) auf Anfrage · auf Normzahlen gerundete Werte
values Max. motor
For maximum mögliche Motorbaugrößen:
sizes siehe Maßblätter
please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 079
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V° = Volume flow [m3/h] or [m/s] Tip speed u = 33 m/s Moment of inertia II== 0.041 2 ° = Volume flow [m3/h] or [m/s] 2
= Volumenstrom [m3/h] bzw. [m3/s] 2
Umfangsgeschwindigkeit u2 = 33 m/s Trägheitsmoment 0,041kg/m
kg m2 V Tip speed u2 = 67 m/s
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 67 m/s Moment of inertia I I==0.041
Trägheitsmoment 0,041kg/m
kg m2
pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C
␦ Casing diameter d.i.L.d.i.L.
= 450= mm pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C Casing diameter d.i.L. d.i.L.
= 450=mm
pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] Temperatur t = 20° C 3 Schachtdurchmesser 450 mm pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] Temperatur t = 20° C3 ␦ Schachtdurchmesser 450 mm
c = Flow velocity [m/s] Density = 1.2 kg/m Outlet cross section A
A2 == 0,159 m22
0.159 m c = Flow velocity [m/s] Density = 1.2 kg/m 3 Outlet cross section A 2
c = Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m3 Austrittsquerschnitt 2 c = Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m Austrittsquerschnitt A2 == 0.159
0,159 m
m2 2
280
BVAXN 12/56/450/D – n = 1400 rpm BVAXN 12/56/450/D – n = 2860 rpm
1400
0,75 = 0,66
250 0,72 1250
0,63
0,85 = 0,76
224 1120 0,82 0,73
0,67
0,58
pd
200 0,62 1000
0,52 0,77
0,68
pd
180 900 0,72
25° 0,62
pd
160
(Pa)➞➞
800 25°
(Pa)➞➞
35°
pd
0,53 Blade pitch angle
Schaufelwinkel
pressure increase 6⌬ptpt[Pa]
pt[Pa]
140 20° 710 35°
Blade pitch angle
0,63 Schaufelwinkel
pressure increase 6⌬ pt
30° 20°
125 630
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
30°
112 15° 0,43 560
· ·
100
25° 15° 0,53
500
25°
90 0,33 450
0° 0° 5° 5° 10° 10° 15° 20° 0,43 20°
0° 0° 5° 5° 10° 10° 15°
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
Leistungsbedarf
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW]
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
Pw = = [kW]
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
[m3/s] ➞ [m3/s] ➞
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c [m/s] ➞ c [m/s] ➞
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
40
50
63
80
100
125
160
200
250
315
400
500
630
with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞ with duct 2.52,5
DD pd [Pa] ➞
mit Rohrleitung
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
45
c [m/s] ➞ c [m/s] ➞
20
25
31,5
40
50
63
80
100
125
160
200
250
315
80
100
125
160
200
250
315
400
500
630
800
1 000
1 250
pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree outlet
ausblasend
92
Gesamt-Schalleistungspegel Lw [dB]
acoustic power level
108
Gesamt-Schalleistungspegel Lw [dB]
=
5° 91 107
V̇[m3/h] · ⌬pt [Pa]
15° 90
· 1000 · 3600
10°
an der
106
an der
5°
power input
power input
89 105
0° 35° 88 15° 104
10°
Leistungsbedarf
30°
Leistungsbedarf
87
requirement
25° 103
requirement
35°
86 0° 102
Max. mögliche 20° Max. mögliche 30°
85 25° 101
Motorbau-
Lw (dB)
Motorbau-
Pw [kW]=
Lw (dB)
Pw [kW]=
84
Welle:
Shaft
Welle:
Shaft
Maßblätter 83 20° 99
82 Maßblätter
98
100 0,72
0,56 0,63
pd
0,46
0,67
90 250 0,57
25°
pd
80 224 25°
(Pa)➞➞
pd
(Pa)➞➞
35°
BVAXN 12/56
0,47 Schaufelwinkel
Blade pitch angle 35°
pt[Pa]
pressure increase 6⌬ptpt[Pa]
71 200
20° 0,58 Blade pitch angle
Schaufelwinkel
⌬ pt
20°
pressure increase 6
63 30° 180
Total Totaldruckerhöhung
TotalTotaldruckerhöhung
30°
56 160
15° 0,37 ·
· 15° 0,48
50 25° 140
25°
45 125
20°
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 0,38
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
Leistungsbedarf
2 000
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW]
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
Pw = = [kW]
0,56
0,63
0,71
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
[m3/s] ➞ [m3/s] ➞
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
c [m/s] ➞ c [m/s] ➞
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
c [m/s] ➞ c [m/s] ➞
25
31,5
40
50
63
80
100
125
160
200
250
315
400
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
97
w [dB]
87
w [dB]
acoustic powerLlevel
5°
=
acoustic power Llevel
=
86 96
5°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
95
· 1000 · 3600
85
an der
· 1000 · 3600
Gesamt-Schalleistungspegel
an der
Gesamt-Schalleistungspegel
power input
10° 15° 94
power input
84
83 10° 15° 93
Leistungsbedarf
0° 35°
Leistungsbedarf
82 92
requirement
30°
requirement
25° 0° 35° 91
81 Max. mögliche 30°
Max. mögliche 25° 90
20° 80 Motorbau-
Motorbau-
Lw (dB)
Pw [kW]=
Lw (dB)
89
Welle:
Shaft
Pw [kW]=
79
Welle:
Shaft
78 Maßblätter 88
Maßblätter 87
77
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 080
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
1800
BVAXN 12/56/500/D – n = 2880 rpm 200
BVAXN 12/56/560/D – n = 920 rpm
1600 0,87 = 0,78 180 0,76 = 0,67
0,84 0,75 0,73 0,64
1400 160
pd
pd
0,74 0,63
1120 0,64 125 0,53
25° 25°
pd
pd
1000 112
(Pa)➞➞
➞
(Pa) ➞
35° 35°
pt [Pa]
800 90
30° 30°
Totaldruckerhöhung
TotalTotaldruckerhöhung
710 80
· 15° 0,55 · 15° 0,44
Total pressure
630 71
25° 25°
560 20° 63
20°
0,45 0,34
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15°
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
[m3/s] ➞ [m3/s] ➞
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
c [m/s] ➞ c [m/s] ➞
50
63
80
100
125
160
200
250
315
400
500
630
800
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
45
50
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
c [m/s] ➞ c [m/s] ➞
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
110
Gesamt-Schalleistungspegel Lw [dB]
92
Gesamt-Schalleistungspegel Lw [dB]
Total acoustic power level
acoustic power level
=
=
109 5° 91
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
5°
· 1000 · 3600
108 90
· 1000 · 3600
an der
an der
power input
power input
0° 105 0° 87
requirement
35°
requirement
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
Welle:
Shaft
102 84
Welle:
20°
Shaft
Tip speed u2 = 41 m/s 2 ° = Volume flow [m3/h] or [m/s] Tip speed u2 = 23 m/s 2
V° = =Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 41 m/s Moment of inertia I I==0.12
Trägheitsmoment 0,12kg/m
kg m2 V
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 23 m/s Moment of inertia I I==0.223
Trägheitsmoment 0,223kg/m
kg m2
3 Temperature t = 20 °C pd 3 Temperature t = 20 °C
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C
␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 565=mm565 mm pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C3
␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 634=mm634 mm
Density = 1.2 kg/m33 2 Density 22
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m Outlet cross section A = 0.25
Austrittsquerschnitt A2 = 0,25 m2 m
2
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Dichte == 1.2
1,2 kg/m
kg/m3 Outlet cross section A = 0.31
Austrittsquerschnitt A = 0,31 m
2 m
2
500
BVAXN 12/56/560/D – n = 1400 rpm 140
BVAXN 12/56/630/D – n = 690 rpm
450 0,84 = 0,75 125 0,74 = 0,65
0,81 0,72 0,71 0,62
400 112
0,76 0,66
355 0,67 100 0,57
pd
pd
0,71 0,61
0,61 0,51
315 90
25° 25°
pd
pd
280 80
(Pa)➞➞
(Pa)➞➞
35° 35°
pressure increase 6⌬ptpt[Pa]
pt[Pa]
0,62
Blade pitch angle
250 Schaufelwinkel 71 0,52 Schaufelwinkel
Blade pitch angle
20° 20°
pressure increase 6⌬pt
224 63
30° 30°
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
200 56
· 15° 0,52 · 15° 0,42
180 50
25° 25°
160 20° 45
0,32
0,42
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15° 20°
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
0,8
0,9
1,0
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
[m3/s] ➞ [m3/s] ➞
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
c [m/s] ➞ c [m/s] ➞
16
20
25
31,5
40
50
63
80
100
125
160
200
250
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
c [m/s] ➞ c [m/s] ➞
31,5
40
50
63
80
100
125
160
200
250
315
400
500
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree
ausblasend
outlet
99
w [dB]
88
w [dB]
Total acoustic powerLlevel
=
5° 98 87
V̇[m3/h] · ⌬pt [Pa]
[Pa]
⌬pt [Pa]
5°
· 1000 · 3600
97 86
an der
3600
1000 ·· 3600
der
Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
an der
power input
power input
96 85
/h] ·· ⌬pt
95 84
· 1000
35°
Leistungsbedarf
Leistungsbedarf
V̇[m33/h]
Leistungsbedarf
0° 94 0° 83
requirement
requirement
35°
30° 30°
V̇[m
·
93 82
Max. mögliche 25° Max. mögliche 25°
92 81
Motorbau- Motorbau-
Lw (dB)
Pw [kW]=
Lw (dB)
[kW]=
Welle:
Shaft
91
PPww [kW]=
20° 20° 80
Welle:
Shaft
Welle:
Maßblätter 90 Maßblätter 79
89 78
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 081
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
flow [m3/h] Tip speed u2 = 30 m/s Moment of inertia II==0.223 2 ° = Volume flow [m3/h] or [m/s] 2
V = =Volume
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 30 m/s Trägheitsmoment 0,223kg/m
kg m2 V = Volumenstrom [m3/h] bzw. [m3/s] Tip speed u2 = 46 m/s
Umfangsgeschwindigkeit u2 = 46 m/s Moment of inertia I I==0.223
Trägheitsmoment 0,223kg/m
kg m2
3 Temperature t = 20 °C Casing diameter d.i.L.d.i.L.
= 634= mm 3 Temperature
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t = 20° C3
␦ Schachtdurchmesser 634 mm pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperatur t t==20°
20 C
°C
␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 634=mm634 mm
cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1,2
1.2 kg/m
kg/m3 Outlet cross section A
Austrittsquerschnitt A2 == 0,31 m22
0.31 m cc ==Flow velocity [m/s]
Srömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3
3 Outlet cross section A
Austrittsquerschnitt A2 == 0.31 m22
0,31 m
2 2
200 500
0,72 0,77
0,63
pd
0,68
pd
180 0,67 450
0,57 0,72
0,62
160 400
25° 25°
pd
pd
140 355
(Pa)➞➞
(Pa)➞➞
35° 35°
0,58 Blade pitch angle
Schaufelwinkel
0,63 Schaufelwinkel
Blade pitch angle
pt[Pa]
pt[Pa]
⌬ pt
6 pt
30°
pressure increase ⌬
pressure increase 6
112 280 30°
Total Totaldruckerhöhung
Total Totaldruckerhöhung
80 0,38 200
0,43
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20°
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
1,12
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
[m3/s] ➞ [m3/s] ➞
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
c [m/s] ➞ c [m/s] ➞
20
25
31,5
40
50
63
80
100
125
160
200
250
315
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
mit Rohrleitung
with duct 2.52,5DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
c [m/s] ➞ c [m/s] ➞
40
50
63
80
100
125
160
200
250
315
400
500
630
16
20
25
31,5
40
50
63
80
100
125
160
200
250
pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree outlet
ausblasend
101
w [dB]
92
w [dB]
acoustic powerLlevel
5°
=
acoustic power Llevel
=
91 5° 100
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
90 99
· 1000 · 3600
15°
· 1000 · 3600
an der
10°
an der
Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
power input
power input
89 10° 15° 98
0° 35° 88 35° 97
30° 0°
Leistungsbedarf
Leistungsbedarf
25° 87 96
requirement
30°
requirement
86 25° 95
Max. mögliche 20° Max. mögliche
85 94
Motorbau- Motorbau- 20°
Lw (dB)
Pw [kW]=
Lw (dB)
Pw [kW]=
84 93
Welle:
Shaft
Welle:
Shaft
Total
Total
Maßblätter 83 Maßblätter 92
82 91
°
V° = =Volume flow [m3/h]
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Tip speed u2 = 26 m/s u = 26 m/s
Umfangsgeschwindigkeit Moment of inertia II == 0.40
Trägheitsmoment 0,40 kg/m
kg m2
2 V ==Volume flow [m /h]
Volumenstrom [m3or/h][m/s]
bzw. [m3/s]
3 Tip speed u2 = 35 m/s
Umfangsgeschwindigkeit u2 = 35 m/s Moment of inertia II== 0.40
Trägheitsmoment kg m22
0,40kg/m
3 2 pd == Dyn. pressure [kp/m32]] Temperaturet =
t =20°
20 C°C
pd
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] Temperaturet =t =20°
Temperatur ␦ 20C°C Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 711= mm
711 mm pd dyn. Druck [Pa][Pa] or xx 0,1
bzw. 0.1 [kp/m Temperatur ␦ Casing diameter d.i.L.d.i.L.
Schachtdurchmesser = 711= mm
711 mm
cc ==Flow velocity [m/s] Density == 1,2
Dichte kg/m33
1.2 kg/m Outlet cross section AA2 == 0,39
Austrittsquerschnitt m22
0.39 m c = Flow velocity [m/s] Dichte == 1,2
Density kg/m33
1.2 kg/m Outlet cross section A = 0.4
Austrittsquerschnitt A22 = 0,4 mm22
Srömungsgeschwindigkeit [m/s] 2 c = Srömungsgeschwindigkeit [m/s]
0,72
140 0,63 280 0,76
pd
0,67
pd
0,67
0,57 0,71
125 250 0,61
25°
pd
112 224
(Pa)➞➞
(Pa)➞➞
25°
pd
BVAXN 12/56
35°
pt[Pa]
pressure increase 6⌬ptpt[Pa]
20°
90 180
30°
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
30°
80 160
· 15° 0,48 ·
15° 0,52
71 140
25°
25°
63 0,38 125
20° 0,42
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15°
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
1,25
1,4
1,6
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
[m3/s] ➞ [m3/s] ➞
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
c [m/s] ➞ c [m/s] ➞
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
c [m/s] ➞ c [m/s] ➞
20
25
31,5
40
50
63
80
100
125
160
200
250
315
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
99
w [dB]
92
w [dB]
acoustic powerLlevel
acoustic power Llevel
=
=
5° 91 98
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
90 97
· 1000 · 3600
· 1000 · 3600
an der
an der
Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
power input
power input
89 96
10° 15°
88 5° 95
10° 15°
Leistungsbedarf
Leistungsbedarf
87 94
requirement
0°
requirement
35° 0° 35°
30° 86 93
Max. mögliche 25° Max. mögliche
85 30° 92
Motorbau- Motorbau- 25°
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
84 91
Welle:
Shaft
Welle:
Shaft
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 082
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
900
BVAXN 12/56/710/D – n = 1430 rpm BVAXN 12/56/800/D – n = 720 rpm
280
pd
0,66
pd
0,74
560 0,64 180 0,68
0,58
25°
pd
➞➞
➞➞
pd
(Pa)
(Pa)
35°
pressure increase 6⌬ptpt[Pa]
TotalTotaldruckerhöhung
30°
355 112
· 15° 0,55 ·
15° 0,51
315 100
25°
25°
280 90
0,45 20° 0,41 20°
0° 0° 5° 5° 10° 10° 15° 0° 0° 5° 5° 10° 10° 15°
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
1,8
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
[m3/s] ➞ [m3/s] ➞
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
c [m/s] ➞ c [m/s] ➞
25
31,5
40
50
63
80
100
125
160
200
250
315
400
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞ with
mit duct 2.5
Rohrleitung 2,5DD pd [Pa] ➞
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35.5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
c [m/s] ➞ c [m/s] ➞
50
63
80
100
125
160
200
250
315
400
500
630
800
16
20
25
31,5
40
50
63
80
100
125
160
200
250
pd [Pa] ➞ pd [Pa] ➞
freifree outlet
ausblasend freifree
ausblasend
outlet
106
w [dB]
96
w [dB]
acoustic powerLlevel
=
105 95
V̇[m3/h] · ⌬pt [Pa]
5°
· 1000 · 3600
104 94
an der
· 1000 · 3600
5°
an der
Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
power input
power input
103 93
10° 15° 102 92
10° 15°
Leistungsbedarf
35°
Leistungsbedarf
0° 101 91
requirement
35°
requirement
0°
30° 100 90
Max. mögliche 25° Max. mögliche 30°
99 25° 89
Motorbau- Motorbau-
Lw (dB)
Pw [kW]=
Lw (dB)
Pw [kW]=
98 88
Welle:
Shaft
Welle:
Shaft
20°
Total
Maßblätter 97 Maßblätter 87
96 86
0,78
0,69 0,75
pd
0,65
0,73
315 0,63 710
25°
pd
(Pa)➞➞
pd
35°
0,66 Blade pitch
Schaufelwinkel
pt[Pa]
35°
pressure increase 6⌬ptpt[Pa]
20° angle
pressure increase 6
30°
200 450
15° 0,56
15° 0,54
180 400 25°
25°
160 355
20°
0,46
° 0° 0° 5° 5° 10° 10° 15°
0° 0° 5° 5° 10° 10° 15° 0,44
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW]
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
Pw = = [kW]
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
c [m/s] ➞ c [m/s] ➞
31,5
40
50
63
80
100
125
160
200
250
315
400
500
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
c [m/s] ➞ c [m/s] ➞
63
80
100
125
160
200
250
315
400
500
630
800
1000
25
31,5
40
50
63
80
100
125
160
200
250
315
400
pd [Pa] ➞ pd [Pa] ➞
frei ausblasend
free outlet freifree
ausblasend
outlet
110
Gesamt-Schalleistungspegel Lw [dB]
101
w [dB]
acoustic powerLlevel
100 109
V̇[m3/h] · ⌬pt [Pa]
99 108
· 1000 · 3600
· 1000 · 3600
5°
an der
an der
Gesamt-Schalleistungspegel
power input
power input
98 107
5° 15° 97 10° 15° 106
10°
Leistungsbedarf
Leistungsbedarf
0° 96 0° 35° 105
35°
requirement
requirement
95 30° 104
Max. mögliche 30° Max. mögliche
25° 94 25° 103
Motorbau- Motorbau-
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
93 102
Welle:
Welle:
Shaft
Shaft
Total
20° 92 101
Maßblätter Maßblätter
91 100
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 083
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
355
BVAXN 12/56/900/D – n = 720 rpm BVAXN 12/56/900/D – n = 950 rpm
630
pd
pd
0,73 0,74
224 0,63 400 0,64
25° 25°
➞➞
pd
200
pd
355
(Pa)➞➞
(Pa)
35° 35°
pt[Pa]
[Pa]
180 0,64 Schaufelwinkel
Blade pitch angle 315 0,63 Schaufelwinkel
Blade pitch angle
20° 20°
pressure increase 6
160 280
Total Totaldruckerhöhung
30°
TotalTotaldruckerhöhung
30°
140 250
· 0,54 ·
15° 15° 0,53
125 224
25° 25°
112 200
0° 0° 5° 5° 10° 10° 15° 0,44 20° 0,43 20°
0° 0° 5° 5° 10° 10° 15°
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW]
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
Pw = = [kW]
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
[m3/s] ➞ [m3/s] ➞
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
c [m/s] ➞ c [m/s] ➞
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
16
20
25
31,5
40
50
63
80
100
125
160
200
250
mit Rohrleitung
with duct 2.52,5DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
c [m/s] ➞ c [m/s] ➞
20
25
31,5
40
50
63
80
100
125
160
200
250
315
31,5
40
50
63
80
100
125
160
200
250
315
400
500
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet freifree outlet
ausblasend
99
Gesamt-Schalleistungspegel Lw [dB]
105
Gesamt-Schalleistungspegel Lw [dB]
acoustic power level
98 104
V̇[m3/h] · ⌬pt [Pa]
5° 97
· 1000 · 3600
· 1000 · 3600
103
an der
an der
power input
power input
96 5° 102
10° 15° 95 10° 15° 101
Leistungsbedarf
Leistungsbedarf
0° 35° 94 0° 100
35°
requirement
requirement
30° 93 99
Max. mögliche 25° Max. mögliche 30°
92 25° 98
Motorbau- Motorbau-
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
91 97
Welle:
Welle:
Shaft
Shaft
90 20° 96
Maßblätter Maßblätter
89 95
0,66
0,74
900 280 0,64
25°
pd
25°
pd
➞➞
250
➞➞
800
35°
BVAXN 12/56
0,67
(Pa)
(Pa)
450 140
0,47
0° 0° 5° 5° 10° 10° 15° 20° 0,45 20°
0° 0° 5° 5° 10° 10° 15°
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
[m3/s] ➞ [m3/s] ➞
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c [m/s] ➞ c [m/s] ➞
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
40
50
63
80
100
125
160
200
250
315
400
500
630
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
45
c [m/s] ➞ c [m/s] ➞
25
31,5
40
50
63
80
100
125
160
200
250
315
400
80
100
125
160
200
250
315
400
500
630
800
1 000
1 250
pd [Pa] ➞ pd [Pa] ➞
freifree
ausblasend
outlet frei ausblasend
free outlet
102
w [dB]
111
w [dB]
acoustic powerLlevel
5° 110 101
V̇[m3/h] · ⌬pt [Pa]
109 5° 100
· 1000 · 3600
· 1000 · 3600
an der
an der
Gesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
10° 15°
power input
power input
108 99
0° 35° 107 10° 15° 98
Leistungsbedarf
Leistungsbedarf
requirement
25° 96
105 30°
Max. mögliche Max. mögliche 25°
20° 104 95
Motorbau- Motorbau-
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
103 94
Welle:
Shaft
Welle:
Shaft
Total
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 084
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
800
BVAXN 12/56/1000/D – n = 950 rpm 1800
BVAXN 12/56/1000/D – n = 1450 rpm
0,89 = 0,80
710 0,89 = 0,80 1600
0,86 0,77
0,86 0,77
630 1400
0,81
560 0,81 1250 0,72
pd
0,72 0,76
pd
0,76 0,66
500 0,66 1120
25°
pd
25°
pd
450 1000
(Pa)➞➞
(Pa)➞➞
35°
35° 0,67 Schaufelwinkel
Blade pitch angle
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
250 560
20° 0,47
0° 0° 5° 5° 10° 10° 15° 0,47 0° 0° 5° 5° 10° 10° 15° 20°
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
[m3/s] ➞ [m3/s] ➞
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
c [m/s] ➞ c [m/s] ➞
50
63
80
100
125
160
200
250
315
400
500
630
800
20
25
31,5
40
50
63
80
100
125
160
200
250
315
14
16
18
20
22,4
25
28
31,5
35,5
40
45
50
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c [m/s] ➞ c [m/s] ➞
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
40
50
63
80
100
125
160
200
250
315
400
500
630
pd [Pa] ➞ pd [Pa] ➞
free
frei outlet
ausblasend freifree outlet
ausblasend
115
w [dB]
108
Gesamt-Schalleistungspegel Lw [dB]
=
=
107 5° 114
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
· 1000 · 3600
106 113
an der
an der
Gesamt-Schalleistungspegel
15°
power input
10°
power input
5° 105 112
10° 15° 104 35° 111
0° 0°
Leistungsbedarf
Leistungsbedarf
Lw (dB)
Lw (dB)
Pw [kW]=
Pw [kW]=
Welle:
Shaft
100 107
Welle:
Shaft
560
BVAXN 12/56/1120/D – n = 720 rpm 1000
BVAXN 12/56/1120/D – n = 980 rpm
0,89 = 0,80
500 0,88 = 0,79 900 0,86 0,77
0,85 0,76
450 800
0,81
0,72
pd
0,66
0,75
355 0,65 630
25°
pd
25°
pd
315 560
(Pa)➞➞
(Pa)➞➞
35°
0,67
Blade pitch angle
Schaufelwinkel
35°
pt[Pa]
pt[Pa]
⌬ pt
20°
pressure increase ⌬
30°
pressure increase 6
250 450
30°
Total Totaldruckerhöhung
TotalTotaldruckerhöhung
20 000
22 400
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
25 000
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · 6 pt
Pw = = [kW] Pw = = [kW]
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
[m3/s] ➞ [m3/s] ➞
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
c [m/s] ➞ c [m/s] ➞
16
20
25
31,5
40
50
63
80
100
125
160
200
250
31,5
40
50
63
80
100
125
160
200
250
315
400
500
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
c [m/s] ➞ c [m/s] ➞
31,5
40
50
63
80
100
125
160
200
250
315
400
500
63
80
100
125
160
200
250
315
400
500
630
800
1000
pd [Pa] ➞ pd [Pa] ➞
free
frei outlet
ausblasend freifree
ausblasend
outlet
106
Lw [dB]
111
w [dB]
Total acoustic power level
acoustic powerLlevel
5°
=
105 110
V̇[m3/h] · ⌬pt [Pa]
5° 104 109
· 1000 · 3600
· 1000 · 3600
an der
an der
LGesamt-Schalleistungspegel
Gesamt-Schalleistungspegel
10° 15°
power input
power input
103 108
10° 15° 35°
102 0° 107
Leistungsbedarf
Leistungsbedarf
requirement
Lw (dB)
Pw [kW]=
Pw [kW]=
98 103
Welle:
Shaft
Welle:
Shaft
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300/400°C – 120 MIN 085
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V° = =
Volume flow [m3/h] Tip speed u2 = 49 m/s Moment of inertia II==6.25
6,25kg/m
2 V° = Volume flow [m3/h] or [m/s] Tip speed u2 = 64 m/s Moment of inertia I = 6.25 kg/m 2 2
Volumenstrom [mor [m/s]
3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 49 m/s Trägheitsmoment kg m2 = Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 64 m/s Trägheitsmoment I = 6,25 kg m
pd 3 Temperature
Temperatur t t==20°
20 C
°C Casing diameter d.i.L.d.i.L.
= 1261 mm mm pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C Casing diameter d.i.L. = 1261 mm
pd == Dyn.
dyn. pressure
Druck [Pa][Pa] or xx 0.1
bzw. 0,1 [kp/m
[kp/m2]] ␦ Schachtdurchmesser = 1261 pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] ␦
Temperatur t = 20° C3 Schachtdurchmesser d.i.L. = 1261 mm
cc ==Flow velocity [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3
3 Outlet cross section A
Austrittsquerschnitt A2 == 1,25 m22
1.25 m cc ==Flow velocity [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Outlet cross section A
Austrittsquerschnitt A2 == 1.25 m22
Srömungsgeschwindigkeit [m/s] 2 Srömungsgeschwindigkeit [m/s] 2 1,25 m
710
BVAXN 12/56/1250/D – n = 740 rpm 1250
BVAXN 12/56/1250/D – n = 980 rpm
0,89 = 0,80 0,89 = 0,80
630 0,86 1120
0,77 0,86 0,77
560 1000
0,81 0,81
0,72
pd
0,72
pd
500 0,76 900
0,66 0,76
0,66
450 800
25°
pd
25°
pd
➞➞
➞
35°
0,67
(Pa) ➞
Blade pitch
Schaufelwinkel
0,67 Blade pitch angle
(Pa)
Schaufelwinkel
angle
pressure increase 6⌬ptpt[Pa]
increase ⌬∆ pt [Pa]
355 20° 630 20°
30° 30°
315 560
TotalTotaldruckerhöhung
Totaldruckerhöhung
280 15° 0,57 500 15° 0,57
· ·
25°
Total pressure
250 450 25°
28 000
31 500
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
40 140 000
Leistungsbedarf Leistungsbedarf
an der Welle: [m3/h] ➞ an der Welle: [m3/h] ➞
· 6 pt · ∆ pt
Pw = = [kW] Pw = = [kW]
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
10
11,2
12,5
14
16
18
20
22,4
25
[m3/s] ➞ [m3/s] ➞
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c [m/s] ➞ c [m/s] ➞
20
25
31,5
40
50
63
80
100
125
160
200
250
315
40
50
63
80
100
125
160
200
250
315
400
500
630
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
45
c [m/s] ➞ c [m/s] ➞
40
50
63
80
100
125
160
200
250
315
400
500
630
80
100
125
160
200
250
315
400
500
630
800
1000
1250
free outlet pd [Pa] ➞ free outlet pd [Pa] ➞
frei ausblasend frei ausblasend
108
Lw [dB]
114
Gesamt-Schalleistungspegel Lw [dB]
=
· 1000 · 3600
an der
10°
Gesamt-Schalleistungspegel
power input
15°
power input
30°
Leistungsbedarf
requirement
25°
102 25° 108
Max. mögliche 20° Max. mögliche
101 20° 107
Motorbau- Motorbau-
Pw [kW]=
w (dB)
Pw [kW]=
Lw (dB)
Welle:
Shaft
Welle:
Shaft
Total
Maßblätter 99 Maßblätter 105
98 104
L
BVAXN 12/56
Smoke exhaust fan types documented on the
following pages 070+071 may be used for
200/300/°C – 120 MIN
BVAXN 12/56/1120/D - 1450 rpm
BVAXN 12/56/1250/D - 1450 rpm
BVAXN 12/56/1400/D - 740 rpm
BVAXN 12/56/1400/D - 980 rpm
BVAXN 12/56/1600/D - 740 rpm
BVAXN 12/56/1600/D - 980 rpm
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C – 120 MIN 086
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
2240
BVAXN 12/56/1120/D – n = 1450 rpm A1 = 0,68 m2 BVAXN 12/56/1250/D – n = 1450 rpm A1 = 1,07 m2
2800
0,89 = 0,80 0,89 η = 0,80
2000 2500
0,86 0,77 0,86
0,77
1800 2240
0,81 0,81
0,72
pd
pd
1600 2000 0,72
0,76 0,76
0,66 0,66
1400 1800
25° 25°
pd
pd
1250 1600 7
(Pa)➞➞
(Pa)➞➞
35° 0,6
Blade pitch angle 35°
0,67 Schaufelwinkel
pt[Pa]
TotalTotaldruckerhöhung
900 15° 0,57 1120 15°
0,57
800 25°
1000 25°
710 900
0,47
0° 0° 5° 5° 10° 10° 15° 20° 0° 0° 5° 5° 10° 10° 15° 20°
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
40 140 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
40 140 000
45 160 000
50 180 000
56 200 000
[m3/h] ➞ [m3/h] ➞
10
11,2
12,5
14
16
18
20
22,4
25
14
16
18
20
22,4
25
[m3/s] ➞ [m3/s] ➞
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
45
c [m/s] ➞ c [m/s] ➞
63
80
100
125
160
200
250
315
400
500
630
800
56 1000
80
100
125
160
200
250
315
400
500
630
800
56 1000
63 1250
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
14
16
18
20
22,4
25
28
31,5
35,5
40
45
50
16
18
20
22,4
25
28
31,5
35,5
40
45
50
c [m/s] ➞ c [m/s] ➞
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
free outlet pd [Pa] ➞ free outlet pd [Pa] ➞
frei ausblasend frei ausblasend
119
Leistungsbedarf an der Welle:
Gesamt-Schalleistungspegel Lw [dB]
Gesamt-Schalleistungspegel Lw [dB]
122
=
· ⌬pt [Pa] =
an der Welle:
Pw [kW] = · 1000 · 3600 =
5° 118 5° 121
Pw [kW] = · 1000 · 3600 =
V̇[m33/h] · ⌬pt [Pa]
117
an der
120
an der
· 1000 · 3600
· 1000 · 3600
10°
power input
116 119
0° 35° 115 0° 35°
118
Leistungsbedarf
/h]
Leistungsbedarf
114 30°
requirement
30° 117
Leistungsbedarf
requirement
25° 25°
[m
113 116
V
·
Lw (dB)
Lw (dB)
Pw [kW]=
Welle:
Shaft
111
Welle:
Shaft
114
110 113
109 112
900
BVAXN 12/56/1400/D – n = 740 rpm A1 = 1,07 m2
1600
BVAXN 12/56/1400/D – n = 980 rpm A1 = 1,07 m2
710 1250
0,81 0,81
0,72
pd
0,72
pd
➞➞
(Pa)
pressure increase ∆⌬ptpt[Pa]
pressure increase ∆⌬ptpt[Pa]
30° 30°
400 710
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
25° 25°
315 560
56 000
63 000
71000
80 000
90 000
28 100 000
40 140 000
45 160 000
50 180 000
56 200 000
35 500
40 000
45 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
40 140 000
[m3/h] ➞ [m3/h] ➞
14
16
18
20
22,4
25
10
11,2
12,5
14
16
18
20
22,4
25
[m3/s] ➞ [m3/s] ➞
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
c [m/s] ➞ c [m/s] ➞
50
63
80
100
125
160
200
250
315
400
500
630
800
25
31,5
40
50
63
80
100
125
160
200
250
315
400
with
mit duct 2.52,5DD
Rohrleitung pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
45
50
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
c [m/s] ➞ c [m/s] ➞
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
50
63
80
100
125
160
200
250
315
400
500
630
800
112
Gesamt-Schalleistungspegel Lw [dB]
an der Welle:
an der Welle:
5° 5°
111 116
Pw [kW] = · 1000 · 3600 =
· V̇[m33/h] · ⌬pt [Pa]
110 115
an der
an der
power input
power input
Leistungsbedarf
30°
/h]
30°
Leistungsbedarf
Leistungsbedarf
107 112
requirement
requirement
25° 25°
[m
106 111
V
Lw (dB)
Lw (dB)
Welle:
Welle:
Shaft
109
Shaft
104
103 108
102 107
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
SERIES BVAXN 12/56
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C – 120 MIN 087
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V° = Volume flow [m3/h] or [m/s] Tip speed u2 = 61 m/s Moment of inertia I = 17.25 kg/m2 2 V° = Volume flow [m3/h] or [m/s] Tip speed u2 = 81 m/s
= Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 61 m/s Trägheitsmoment I = 17,25 kg m = Volumenstrom [m3/h] bzw. [m3/s] Umfangsgeschwindigkeit u2 = 81 m/s Moment of inertia I I==17.25
Trägheitsmoment kg m22
17,25kg/m
pd = Dyn. pressure [Pa] or x 0.1 [kp/m32] Temperature t = 20 °C ␦ Casing diameter d.i.L. = 1587 mm pd
pd == Dyn.
dyn. pressure [Pa] or xx 0.1
0,1 [kp/m
3
[kp/m2]] Temperature
Temperatur tt==20°
20 °C
C3 ␦ Casing diameter d.i.L. d.i.L.
Schachtdurchmesser = 1587 mm mm
= 1587
pd = dyn. Druck [Pa] bzw. x 0,1 [kp/m ] Temperatur t = 20° C3 Schachtdurchmesser d.i.L. = 1587 2
mm Druck [Pa] bzw.
Density = 1.2 kg/m Outlet cross section AA2 ==1.98
cc ==Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Dichte = 1,2 kg/m3 Austrittsquerschnitt 1,98mm2 2
cc = =Flow velocity [m/s]
Strömungsgeschwindigkeit [m/s] Density
Dichte == 1.2
1,2 kg/m
kg/m3 Austrittsquerschnitt
Outlet cross section A A2 == 0,31 m22
1,98 m 2
1120
BVAXN 12/56/1600/D – n = 740 rpm A1 = 1,31 m2
2000
BVAXN 12/56/1600/D – n = 980 rpm A1 = 1,31 m2
0,89 = 0,80
0,89 = 0,80
1000 0,86 0,77 1800
0,86 0,77
900 1600
0,81
0,72 0,81
pd
0,72
pd
800 0,76 1400
0,66 0,76
0,66
710 25° 1250
pd
25°
pd
630 1120
(Pa)➞➞
(Pa)➞➞
35°
0,67
Blade pitch angle
Schaufelwinkel 35°
0,67
Blade pitch angle
Schaufelwinkel
20°
TotalTotaldruckerhöhung
TotalTotaldruckerhöhung
71000
80 000
90 000
28 100 000
40 140 000
45 160 000
50 180 000
56 200 000
63 224 000
71 250 000
80 280 000
50 000
56 000
63 000
71 000
80 000
90 000
28 100 000
40 140 000
45 160 000
50 180 000
56 200 000
[m3/h] ➞ [m3/h] ➞
20
22,4
25
14
16
18
20
22,4
25
[m3/s] ➞ [m3/s] ➞
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
c [m/s] ➞ c [m/s] ➞
63
80
100
125
160
200
250
315
400
500
630
800
56 1000
31,5
40
50
63
80
100
125
160
200
250
315
400
500
with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞ with
mit duct 2.52,5
Rohrleitung DD pd [Pa] ➞
14
16
18
20
22,4
25
28
31,5
35,5
40
45
50
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
35,5
40
c [m/s] ➞ c [m/s] ➞
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
63
80
100
125
160
200
250
315
400
500
630
800
1000
Gesamt-Schalleistungspegel Lw [dB]
114
Leistungsbedarf an der Welle:
Gesamt-Schalleistungspegel Lw [dB]
Total acoustic power level
5°
Pw [kW]= V· [m3/h] · ⌬pt [Pa] =
5°
Pw [kW] = · 1000 · 3600 =
Pw [kW] = · 1000 · 3600 =
113 119
V̇[m33/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
10°
an der
· 1000 · 3600
· 1000 · 3600
15°
Shaft power input
Leistungsbedarf
Leistungsbedarf
115
requirement
Lw (dB)
106 112
Welle:
Welle:
105 111
104 110
BVAXN 12/56
Consisting of
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box
Surface protection:
• Polyester powder coating, colour: RAL 7030
• as of nominal size 1120: with full paint finish, colour: RAL7030
or • Hot-dip galvanized
Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Technical data:
Volume flow m3/h
Temperature / humidity °C/%RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level LW dB
Efficiency %
Power input requirement kW
Three-phase motor
single-speed
or Dahlander pole-changing type
or pole-changing type with separate windings
Accessory equipment
• Galvanised fan
• Fan with special coating
• Extension casing without inspection hatch
• Inspection hatch
• Bellmouth inlet with flange
• Wire guard on bellmouth side
• Wire guard on extension casing (motor side)
• Flexible connector, inlet side*
• Flexible connector, outlet side*
• Matching flange inlet side*
• Matching flange outlet side*
• Angular wall ring with brackets*
• Set of mounting feet (2 pcs.)*
• Set of spring-type antivibration mounts*
• Brackets for vertical fan installation
• Diffuser with interior core*
• Round silencer, TSR type*
BVAXN 12/56
Note:
* Loosely supplied
– 090 –
Unit price Total
Item
Qty. Description
No.
2 2
Consisting of:
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box
Surface protection:
• Polyester powder coating, colour: RAL 7030
• as of nominal size 1120: with full paint finish, colour: RAL 7030
or • Hot-dip galvanized
Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Specifications
Volume flow m3/h
Temperature / humidity °C /% RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level LW dB
Efficiency %
Power input requirement kW
Three-phase motor
single-speed
or Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Current consumption A
Voltage V
Frequency Hz
Protection class (IP)
Type B/V
Size
Weight: fan with accessories approx. kg
Manufacturer: TLT-Turbo GmbH
Carryover
– 091 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Accessory equipment:
• Galvanised fan
• Inspection hatch
BVAXN 12/56
Note:
* Loosely supplied
– 092 –
Unit price Total
Item
Qty. Description
No.
2 2
Consisting of:
Casing of welded sheet steel construction
with drilled flanges according to DIN 24 154, Series 3;
Outlet guide vanes for boosting outlet pressure and
achieving an essentially swirl-free outlet flow;
special motor placed within the smoke fume flow,
wired to exterior temperature-resistant terminal box
Surface protection:
Polyester powder coating, colour: RAL 7030
as of nominal size 1120: with full paint finish, colour: RAL7030
or Hot-dip galvanized
Outlet-side installation:
Duct connection
or Direct outlet without diffuser
or Outlet into diffuser (optional)
Technical data:
Volume flow m3/h
Temperature/air humidity C/% RH
Dynamic pressure Pa
Total pressure increase Pa
Fan speed rpm
Blade pitch angle deg.
Total acoustic power level Lw dB
Wfficiency %
Power input requirement kW
Three-phase motor:
single speed
or Dahlander pole-changing type
or pole-changing type with separate windings
Carryover
– 093 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Accessory equipment:
• Galvanised fan
• Inspection hatch
BVAXN 12/56
Note:
* Loosely supplied
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C - 120 MIN 095
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Øk
i.d.
➞
Ød1
ØD
max. Weight
approx.
Size i.d. motor kg (without
size motor)
BVAXN 8/56
500
700
920
1210
Dimensional and design changes reserved. blade pitch angle 0 to 15° Dimensions in mm
blade pitch angle 16 to 35°
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
600°C – 120 MIN 096
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
appr. 60
i.d.3
i.d.3
i.d.2
appr. 80
Installation
length
500 708 509 98 375 735 705 460 380 5x12 506 507 541 571 12x9,5 80 50
630 875 640 95 470 933 893 550 470 5x12 637 638 674 712 16x11,5 100 70
710 972 717 103 525 990 950 620 530 5x12 714 715 751 785 16x11,5 100 70
800 1081 801 115 585 1125 1085 730 640 5x14 800 801 837 875 24x11,5 100 70
900 1214 898 130 655 1198 1154 730 640 5x14 897 898 934 972 24x11,5 100 70
1000 1351 1009 145 730 1342 1296 830 740 5x14 1006 1007 1043 1081 24x11,5 100 70
1120 1470 1130 160 760 1487 1441 920 820 5x14 1133 1134 1174 1214 24x11,5 110 90
1250 1677 1263 185 855 1837 1791 1030 930 5x14 1270 1271 1311 1351 24x11,5 110 90
1400 1870 1417 210 930 2087 2041 1140 1040 5x14 1424 1425 1465 1505 24x11,5 130 100
1600 2087 1587 210 1020 2342 2296 1350 1230 5x18 1596 1597 1637 1677 32x11,5 130 100
Dimensional and design changes reserved. *All accessories except for mounting feet and Dimensions in mm
extension casings will be supplied loosely.
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
ACCESSORIES*
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 097
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Mounting brackets for vertical installation (direct-driven fans only) Diffuser with interior core
E F
i. d2
i.d.
Y
H
H1
L1
w2
a1
b1 162 262 312 202
a3
a
ta – – – 88
ød
ta
xb · t – – – 1 x 125
°
45 tb – 118 143 113
b tb xb·t w2 13 13 13 13
d 10 10 10 10
L5
zxd Wire guard L3
BVAXN 8/56
Size A A1 b Ø d i.d. Øk ØD zxd H H1 X Y Z i.d.2 Ø d3 Ø k2 Ø D2 z x d2 L1 L2 L3 L4 L5 L6
500 657 705 80 11,5 504 541 571 12x9,5 450 225 391 379 177 634 282 674 712 16x11,5 600 280 60 450 305 355
630 852 900 90 11,5 634 674 712 16x11,5 572 286 462 458 271 797 355 837 875 24x11,5 750 330 70 500 375 400
710 929 977 100 11,5 711 751 789 16x11,5 610 305 404 535 285 894 397 934 972 24x11,5 850 350 70 630 420 450
800 1015 1063 100 11,5 797 837 875 24x11,5 700 350 457 618 337 1003 446 1043 1081 24x11,5 950 520 200 710 474 500
900 1112 1160 100 11,5 894 934 972 24x11,5 746 373 499 646 353 1124 502 1174 1254 24x11,5 1060 585 225 800 541 560
1000 1221 1269 100 13,5 1003 1043 1081 24x11,5 830 415 551 714 411 1261 562 1311 1391 24x11,5 1200 640 240 900 612 630
1120 1374 1434 120 13,5 1124 1174 1254 24x11,5 570 635 935 345 1415 630 1465 1545 24x11,5 1340 730 250 1000 678 710
1250 1511 1571 120 13,5 1261 1311 1391 24x11,5 400 700 1168 445 1587 710 1637 1717 32x11,5 1510 810 250 1120 761 800
1400 1665 1725 120 13,5 1415 1465 1545 24x11,5 700 785 1108 845 1780 789 1830 1910 32x11,5 1690 800 160 1250 848 900
1600 1837 1897 120 13,5 1587 1637 1717 32x11,5 600 850 1235 905 1997 888 2047 2167 32x11,5 1900 900 180 1400 940 1000
Dimensional and design changes reserved. Sizes 500+630 = 30° *please see page 096 Dimensions in mm
AXIAL SMOKE EXHAUST FANS
BVAXN 8/56 SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 098
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Acoustic level Starting from this value, the A-weigh- ning, respectively. The values given
ted acoustic power level LWA and the were taken from measurements as
relative acoustic power level LWrel. per EN 25136 (formerly DIN 45 635,
The total acoustic power level Part 9) duct testing method.
can be determined using the tables
LW.Vent. (in dB) of an axial smoke ex- below. These values are available as
haust fan can be obtained directly the acoustic power emitted into the
from the characteristic data sheets for duct and as the acoustic power emit-
each operating point. ted from the fan inlet or outlet ope-
1. Acousting power level emitted into the duct Portion Portion 1.2 at mid-octave frequency [Hz]
Size rpm 1.1
The level of acoustic power an axial smoke exhaust fan 63 125 250 500 1000 2000 4000 8000
emits into the ducting is used for calculating the sound po- 500 675 9 5 3 9 12 16 18 21 31
wer characteristics of downstream systems, e.g., silencers. 900 8 6 4 9 10 13 17 18 27
1400 5 7 8 5 9 10 14 16 19
The levels are calculated as follows: 2800 2 8 10 11 7 8 8 12 14
630 710 8 6 4 9 10 13 17 18 27
Lwvent. [dB] = total acoustic power emitted by the fan, 920 6 6 4 9 9 11 15 16 22
(please see respective characteristic curve 1410 4 7 9 6 9 9 12 15 16
710 710 6 6 4 9 10 12 16 17 24
sheets) 950 6 7 4 10 9 10 14 16 19
1450 4 7 9 6 10 8 10 14 15
LwA vent. [dB] = A-weighted acoustic power level, according 800 720 6 6 4 10 10 11 15 16 22
to the equation 960 5 7 5 10 9 2 13 15 18
1460 3 8 9 6 10 8 10 14 15
LwA vent. = Lwvent. – portion 1.1 [dB] 900 720 6 6 4 10 9 10 14 16 20
960 5 7 5 10 10 9 12 15 18
Lwrel vent. [dB] = relative acoustic power level as expressed 1460 3 8 9 6 11 8 9 13 14
by the equation 1000 720 5 6 5 10 10 9 13 15 18
970 4 7 5 10 10 8 11 15 15
Lwrel vent. = Lwvent. – portion 1.2 [dB] 1460 3 8 10 7 12 8 8 12 14
1120 730 5 7 5 11 10 9 12 15 17
980 4 7 5 11 11 8 10 14 15
1250 740 4 7 5 11 10 8 11 15 15
980 3 8 6 11 12 8 9 13 14
2. Acoustic power emitted from the fan inlet or outlet 1400 740 4 7 5 12 10 8 10 14 15
opening 980 3 8 6 11 12 8 8 12 14
1600 740 3 7 6 12 11 8 9 13 14
To determine the sound levels at a given installation site, 980 3 8 6 12 13 8 8 11 14
it is usually necessary to know the level of acoustic power
emitted from the fan’s inlet or outlet opening. The adjacent Size rpm
Portion Portion 2.2 at mid-octave frequency [Hz]
2.1
tables are based on the outlet reflection pattern assumed 63 125 250 500 1000 2000 4000 8000
in VDI 2081, Case 2. 500 675 10 16 9 11 12 16 18 21 31
900 8 17 9 10 10 13 17 18 27
LwA op. [dB] = A-weighted level of acoustic power emitted from 1400 5 18 13 7 9 10 14 16 19
the fan’s opening, expressed by the equation 2800 3 19 15 13 7 8 8 12 14
630 710 8 15 8 10 10 13 17 18 27
LwA op. = Lwvent. – portion 2.1 [dB] 920 7 15 8 10 10 13 17 18 27
1410 4 16 12 7 9 9 12 15 16
Lwrel op. = relative level of acoustic power emitted from the 710 710 7 14 8 10 10 12 16 17 24
fan’s opening, expressed by the equation 950 6 14 8 10 9 10 14 16 19
1450 4 15 12 7 10 8 10 14 15
Lwrel op. = Lwvent. – portion 2.2 [dB] 800 720 7 13 7 10 10 11 15 16 22
960 5 14 7 10 9 9 13 15 18
1460 3 15 12 7 10 8 10 14 15
900 720 6 12 7 10 9 10 14 16 20
960 5 13 7 10 10 9 12 15 16
1460 3 14 11 7 11 8 9 13 14
1000 720 5 12 7 10 10 9 13 15 18
970 4 12 7 11 10 8 11 15 15
1460 3 13 11 7 12 8 8 12 14
1120 730 5 11 6 11 10 9 12 15 17
980 4 12 7 11 11 8 10 14 15
1250 740 4 11 6 11 10 8 11 15 15
980 3 11 6 11 12 8 9 13 14
1400 740 4 10 6 12 10 8 10 14 15
980 3 11 6 11 12 8 8 12 14
1600 740 3 10 6 12 11 8 9 13 14
980 3 11 6 12 13 8 8 11 14
Note:
Portions 1.1 / 1.2 / 2.1 / 2.2 to be taken frome the above
spreadsheets.
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 8/56 600°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 099
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
500 1000 0,75 2,2 90 B14 160 800 750 0,75 2,3 100 B14 160
1500 1,1 2,6 90 B14 160 1,1 3,28 100 B14 160
1,5 3,5 90 B14 160 1,5 4,2 112 B14 160
3000 4,5 8,5 112 B14 160 2,2 5,6 132 B14 300
1000/500 0,75/0,13 2,8/0,97 90 B14 160 1000 1,5 4,3 100 B14 160
1500/750 1,0/0,25 2,4/1,0 90 B14 160 2,2 5,3 112 B14 160
1,3/0,35 3,6/1,55 90 B14 160 3,0 6,3 132 B14 300
1500/1000 1,3/0,4 3,4/1,38 90 B14 160 4,0 8,6 132 B14 300
3000/1500 4,1/1,1 8,1/2,2 112 B14 160 1500 4,0 8,3 112 B14 160
5,5 11 132 B14 300
630 750 0,55 1,82 90 B14 160
7,5 15 132 B14 300
0,75 2,3 100 B14 160
11 21 160 B14 300
1000 0,75 2,2 90 B14 160
15 28,5 160 B14 300
1,1 3,2 90 B14 160
1000/500 1,2/0,24 3,15/2,1 100 B14 160
1,5 4,3 100 B14 160
2,0/0,33 4,6/2,4 112 B14 160
1500 1,5 3,5 90 B14 160
3,2/0,7 6,8/3,8 132 B14 300
2,2 5,0 100 B14 160
4,4/1,0 9,0/4,5 132 B14 300
3,0 7,0 100 B14 160
1500/750 5,0/1,30 10,7/4,2 132 B14 300
4,0 8,3 112 B14 160
6,8/1,70 14,3/5,2 132 B14 300
1000/500 0,75/0,13 2,8/0,97 90 B14 160
10/3,0 22,3/9,7 160 B14 300
1,2/0,24 3,15/2,1 100 B14 160
14/3,5 29,5/11,8 160 B14 300
2,0/0,33 4,6/2,4 112 B14 160
1500/1000 4,2/1,25 9,0/3,1 132 B14 300
1500/750 2,0/0,45 4,5/1,8 100 B14 160
5,5/1,65 11,2/3,7 132 B14 300
2,5/0,55 5,8/2,1 100 B14 160
9,0/3,0 18/7,1 160 B14 300
3,7/0,9 9,2/3,6 112 B14 160
12/3,5 24/9,5 160 B14 300
1500/1000 2,4/0,75 5,7/2,95 100 B14 160
14/4,5 26,5/11,1 180 B14 350
3,0/0,9 7,0/2,3 112 B14 160
4,2/1,25 9,0/3,1 132 B14 250 900 750 1,1 3,28 100 B14 160
1,5 4,2 112 B14 160
710 750 0,55 1,82 90 B14 160
2,2 5,6 132 B14 300
0,75 2,3 100 B14 160
3,0 7,5 132 B14 300
1,1 3,28 100 B14 160
1000 2,2 5,3 112 B14 160
1000 0,75 2,2 90 B14 160
3,0 6,3 132 B14 300
1,1 3,2 90 B14 160
4,0 8,6 132 B14 300
1,5 4,3 100 B14 160
BVAXN 8/56
5,5 11,5 132 B14 300
2,2 5,3 112 B14 160
7,5 15,8 160 B14 300
3,0 6,3 132 B14 300
1500 7,5 15 132 B14 300
1500 2,2 5,0 100 B14 160
11 21 160 B14 300
3,0 7,0 100 B14 160
15 28,5 160 B14 300
4,0 8,3 112 B14 160
1500 18,5 34,5 180 B14 350
5,5 11 132 B14 300
22 41 180 B14 350
7,5 15 132 B14 300
30 55 200 B14 350
1000/500 1,2/0,24 3,15/2,1 100 B14 160
1000/500 2,0/0,33 4,6/1,6 112 B14 160
2,0/0,33 4,6/2,4 112 B14 160
3,2/0,7 6,8/3,8 132 B14 300
1500/750 2,5/0,6 5,8/2,1 100 B14 160
4,4/1,0 9,9/4,5 132 B14 300
3,7/0,9 9,2/3,6 112 B14 160
6,2/1,3 13,3/3,6 160 B14 300
5,0/1,3 10,7/4,2 132 B14 300
8,4/1,8 17,1/4,8 160 B14 300
6,8/1,7 14,3/5,2 132 B14 300
1500/750 6,8/1,7 14,3/5,2 132 B14 300
1500/1000 2,4/0,75 5,7/2,95 100 B14 160
10/3,0 22,3/9,7 160 B14 300
3,0/0,9 7,0/2,3 112 B14 160
4,2/1,25 9,0/3,1 132 B14 300
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
5,5/1,65 11,2/3,7 132 B14 300
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
TECHNICAL LISTS (AVAILABLE MODELS)
BVAXN 8/56 600°C - 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 100
Tel.: +49.6621.950-0 · Fax: +49.6621.950-100
900 1500/750 14/3,5 29,5/11,8 160 B14 300 1250 750 5,5 13 160 B14 300
16/4,0 30/13,1 180 B14 350 7,5 17,2 160 B14 300
20/5,0 39/13,8 180 B14 350 11 23 180 B14 350
28/7,0 52/15,2 200 B14 350 15 32,5 200 B14 350
1500/1000 9,0/3,0 18/7,1 160 B14 300 18,5 39 225 B14 450
12/3,5 24/9,5 160 B14 300 1000 11 22,5 160 B14 300
14/4,5 26,5/11,1 180 B14 350 15 30,5 180 B14 350
16,5/5,5 32/11,8 180 B14 350 22 44 200 B14 350
20/7,0 35/13,7 200 B14 350 30 58 225 B14 450
28/9,0 47,5/18,6 200 B14 350 37 74 250 B14 550
1000/500 12,5/3,0 24/7,5 180 B14 350
1000 1500 11 21 160 B14 300
20/4,5 38,5/13 200 B14 350
15 28,5 160 B14 300
22/5,0 41/13,3 225 B14 450
18,5 34,5 180 B14 350
27/6,0 51/18 225 B14 450
22 41 180 B14 350
30/7,0 58/19 250 B14 550
30 55 200 B14 350
1000/500 4,4/1,0 9,0/4,5 132 B14 300 1400 750 7,5 17,2 160 B14 350
6,2/1,3 13,3/3,6 160 B14 300 11 23 180 B14 350
8,4/1,8 17,1/4,8 160 B14 300 15 32,5 200 B14 350
12,5/3,0 24/7,5 180 B14 350 18,5 39 225 B14 450
1500/750 10/3,0 22,3/9,7 160 B14 300 22 47,5 225 B14 450
14/3,5 29,5/11,8 160 B14 300 30 60 250 B14 550
16/4,0 30/13,1 180 B14 350 1000 22 44 200 B14 350
20/5,0 39/13,8 180 B14 350 30 58 225 B14 450
28/7,0 52/15,2 200 B14 350 37 74 250 B14 550
1500/1000 12/3,5 24/9,5 160 B14 300 45 81 280 B14 550
14/4,5 26,5/11,1 180 B14 350 55 99 280 B14 550
16,5/5,5 32/11,8 180 B14 350 1000/500 20/4,5 38,5/13 200 B14 350
20//7,0 35/13,7 200 B14 350 22/5,0 41,1/13,3 225 B14 450
26/9,0 47,5/18,6 200 B14 350 27/6,0 51/18 225 B14 450
750 2,2 5,6 132 B14 300 30/7,0 58/19 250 B14 550
3,0 7,5 132 B14 300 1000/500 40/8,0 74/24 280 B14 550
4,0 9,25 180 B14 300 48/9,5 88/28 280 B14 550
5,5 13 160 B14 300
1600 750 15 32,5 200 B14 350
1000 4,0 8,6 132 B14 300
18,5 39 225 B14 450
5,5 11,5 132 B14 300
22 47,5 225 B14 450
7,5 15,8 160 B14 300
30 60 250 B14 550
11 22,5 160 B14 300
37 73 280 B14 550
15 30,5 180 B14 350
45 88 280 B14 550
1120 750 3,0 7,5 132 B14 300
4,0 9,25 160 B14 300
5,5 13 160 B14 300
7,5 17,2 160 B14 300
11 23 180 B14 350
1000 7,5 15,8 160 B14 300
11 22,5 160 B14 300
15 30,5 180 B14 350
22 44 200 B14 350
8,4/1,8 17,1/4,8 160 B14 300
12,5/3,0 24/7,5 180 B14 350 Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
20/4,5 38,5/13 200 B14 350 Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 101
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 24 m/s Moment of inertia I = 504 kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 37 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 450 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 504 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2
rpm rpm
➞
➞
Total pressure increase ⌬ pt (Pa)
5° 15°
5° 15°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
10° 20°
· 1000 · 3600
· 1000 · 3600
25° 20°
30° 10° 25°
30°
Shaft power input
Shaft power input
35°
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 76 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 23 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 504 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.2 m2
rpm rpm
Don’t design
in rastered
area
➞
➞
Total pressure increase ⌬ pt (Pa)
BVAXN 8/56
pd
Blade Blade
pitch pitch
angle angle
5°
=
15° 5°
10° 15°
V̇[m3/h] · ⌬pt [Pa]
20° 25°
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
· 1000 · 3600
10° 20°
30° 25°
30°
Total acoustic power
Total acoustic power
Shaft power input
35°
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 102
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 30 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 47 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 634mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 634 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.31 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m 2
0,31
rpm rpm
➞
➞
Total pressure increase ⌬ pt (Pa)
5°
=
15° 5°
15°
V̇[m3/h] · ⌬pt [Pa]
20°
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
25° 20°
· 1000 · 3600
10° 25°
10°
Total acoustic power
35°
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 26 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 35 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 711 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 711 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m2
rpm rpm
➞Total pressure increase ⌬ pt (Pa)
Blade
pitch
angle Blade
pitch angle
5°
=
15° 5° 15°
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
25°
30° 30°
Total acoustic power
Total acoustic power
Shaft power input
35°
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 103
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 54 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 30 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 711 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 797 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.4 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.5 m2
rpm rpm
➞
➞
Blade Blade
pitch pitch
angle angle
25° 5°
10° 20°
25°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
30° 10°
· 1000 · 3600
· 1000 · 3600
35° 30°
Total acoustic power
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
V= Volume flow (m3/h) resp. m/s) Tip speed U2=40 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 61 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C Casing diameter d.i.L. = 797 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 797 mm
␦ Outlet cross section A2 = 0.5 m2
c = Flow velocity (m/s) Density = 1.2 kg/m3 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.5 m2
rpm rpm
➞
➞
BVAXN 8/56
Blade
Blade pitch
pitch angle angle
5° 15°
=
5°
20° 15°
V̇[m3/h] · ⌬pt [Pa]
10° 25°
· 1000 · 3600
· 1000 · 3600
30° 25°
10° 20°
Total acoustic power
Total acoustic power
30°
Shaft power input
35° 35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
* rounded to standard values. For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 104
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 34 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 45 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 894 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 894 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.63 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.63 m2
rpm rpm
➞
➞
Blade
pitch
angle Blade
pitch
angle
5° 15°
=
5° 15°
20° 20° 25°
V̇[m3/h] · ⌬pt [Pa]
10°
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
· 1000 · 3600
35°
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 69 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 38 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 894 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C Casing diameter d.i.L. = 894 mm
Outlet cross section A2 = 0.63 m2
␦
c = Flow velocity (m/s) Density = 1.2 kg/m3 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.63 m2
rpm rpm
➞
➞
Blade
pitch Blade
angle pitch
angle
5° 15°
15°
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
10°
10° 25° 30°
Total acoustic power
30°
Shaft power input
Shaft power input
35°
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 105
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 51 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 76 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1003 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. =1003 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.79 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 0.79 m2
rpm rpm
Don’t design
in the raster
area
➞
➞
Blade
Blade pitch
pitch angle angle
5° 15° 5° 15°
V̇[m3/h] · ⌬pt [Pa]
V̇[m3/h] · ⌬pt [Pa]
· 1000 · 3600
· 1000 · 3600
30° 30°
Shaft power input
Shaft power input
35°
requirement
35°
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 43 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 57 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1124 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1124 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.0 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.0 m2
rpm rpm
➞
➞
Total pressure increase ⌬ pt (Pa)
BVAXN 8/56
Blade Blade
pitch pitch
angle angle
5° 15° 5° 15°
=
20°
10° 25° 20°
V̇[m3/h] · ⌬pt [Pa]
25°
· 1000 · 3600
· 1000 · 3600
35° 35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 106
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 48 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 65 m/s 65 Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1261 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1261 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.25 m2 c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.25 m2
1,25
rpm rpm
➞
➞
Total pressure increase ⌬ pt (Pa)
5° 15° 5°
=
20° 15°
10°
V̇[m3/h] · ⌬pt [Pa]
25°
· 1000 · 3600
20°
· 1000 · 3600
35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 54 m/s Moment of inertia I = kg/m2 V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 72 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1415 mm pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C Casing diameter d.i.L. = 1415 mm
Outlet cross section A2 = 0.57 m2 c = Flow velocity (m/s)
␦ Outlet cross section A2 = 1.57 m2
c = Flow velocity (m/s) Density = 1.2 kg/m3 Density = 1.2 kg/m3
rpm rpm
Don’t design in
the raster area
➞
➞
Total pressure increase ⌬ pt (Pa)
Blade
pitch Blade
angle pitch angle
5° 15°
=
5° 15°
V̇[m3/h] · ⌬pt [Pa]
20°
V̇[m3/h] · ⌬pt [Pa]
10° 20°
· 1000 · 3600
25°
· 1000 · 3600
25° 10°
30° 30°
Total acoustic power
35° 35°
requirement
requirement
level Lw (dB)
level Lw (dB)
Pw [kW]=
Pw [kW]=
* rounded to standard values For maximum motor sizes please see dimension pages
AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE
VANES BVAXN 8/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 107
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V= Volume flow (m3/h) resp. m/s) Tip speed U2 = 62 m/s Moment of inertia I = kg/m2
pd = Dyn. pressure (Pa) or x 0.1 kp/m2 Temperature t = 20°C
␦ Casing diameter d.i.L. = 1587 mm
c = Flow velocity (m/s) Density = 1.2 kg/m3 Outlet cross section A2 = 1.98 m2
rpm
➞Total pressure increase ⌬ pt (Pa)
Blade
pitch
angle
with duct
2.5 D
=
5° 15°
V̇[m3/h] · ⌬pt [Pa]
20°
· 1000 · 3600
10° 25°
30°
Total acoustic power
Shaft power input
35°
requirement
level Lw (dB)
Pw [kW]=
Necessary cooling air V [m3/h] for BVAXN 8/56 series (600°C – 120 min.)
Nominal fan speed (rpm) Type of Motor output Current Flange for
cooling 400 V/50 Hz consumption duct-
750 1000 1500 3000 air fan at 2,800 rpm [A] connection
[kW] [mm]
Size V ⌬pk ⌬pex V ⌬pk ⌬pex V ⌬pk ⌬pex V ⌬pk ⌬pex
500 120 100 430 160 180 300 240 400 50 240 400 50 4-14 0,18 0,52 100x100
BVAXN 8/56
630 120 100 430 160 180 300 240 400 50 4-14 0,18 0,52 100x100
710 120 100 430 160 180 300 240 400 50 4-14 0,18 0,52 100x100
800 265 110 390 355 195 305 530 440 80 5-19 0,25 0,86 200x100
900 265 110 390 355 195 305 530 440 80 5-19 0,25 0,86 200x100
1000 375 140 510 500 250 400 750 565 135 6-35 0,75 1,75 250x100
1120 375 140 510 500 250 400 6-35 0,75 1,75 250-100
1250 375 140 510 500 250 400 6-35 0,75 1,75 250x100
1400 1200 280 820 1800 630 370 8-70 2,2 4,6 315x140
Carryover
– 109 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Carryover
– 110 –
Unit price Total
Item
Qty. Description
No.
2 2
Accessory equipment
• Cooling air fan (standard version)
• Set of mounting feet
• Flexible connector, heat resistant *
- inlet side
- outlet side
• Set of matching flanges *
• Bellmouth incl. flange
• Wire guard
• Set of spring-type AV mounts *
• Brackets for vertical installation
• Diffuser with interior core *
• Wire guard (diffuser-outlet)
• Galvanized fan
• Outlet duct with wire guard *
• Outlet duct with self-activating damper and wire guard *
• Duct with self-activating damper *
In case of installation of BVAXN inside the fire zone
• Flexible connector für connection to cooling air duct
• Longer motor-cable, length ….. m
• Cooling air fan (special version)
• Weather guard for cooling air fan
* Loosely supplied
TWO-STAGE AXIAL SMOKE EXHAUST FANS
BVZAXN 12/56 SERIES
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300/400°C – 120 MIN 113
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
i.d.
➞
Further technical details may be taken from our special Important! This fan series is available only with the motor
catalogue « Multi-Storey Fans for Ventilation and outputs stated in our price lists.
Smoke Extraction ». Please ask for your copy.
up to up to upto
Weight 2) L1* Weight 2) L2* Weight
2)
a1 b1
Size i.d. Øk ØD z x d1) motor L motor y motor H a c b x
[kg] [kg] [kg]
size size size
BVZAXN 12/56
355 359 395 425 8 x 9,5 80 660 25 90 825 8 30 90 990 35 270 356 330 35 330 270 77
400 401 438 468 12 x 9,5 90 752 36 112 940 54 43 112 1128 51 300 406 379 37 370 300 88
450 450 487 517 12 x 9,5 90 800 43 112 1000 34 52 112 1200 62 335 430 400 37 410 330 88
500 504 541 571 12 x 9,5 112 900 56 132 1125 81 68 132 1350 80 375 480 453 37 460 380 100
560 565 605 643 16 x 11,5 112 968 82 132 1210 64 99 132 1452 117 420 519 483 45 510 430 100
630 634 674 712 16 x 11,5 132 1144 105 –– –– –– –– –– -– –– 470 607 575 45 550 470 128
710 711 751 789 16 x 11,5 132 1220 130 160 1525 112 152 160 1830 174 525 645 613 45 620 530 128
800 797 837 875 24 x 11,5 132 1400 164 180 1750 104 198 180 2100 232 585 735 703 45 730 640 150
900 894 934 972 24 x 11,5 132 1492 220 225 1865 78 264 225 2238 309 655 781 753 45 730 640 149
1000 1003 1043 1081 24 x 11,5 160 1660 274 225 2075 113 329 225 2490 383 730 881 833 57 830 740 165
1120 1126 1174 1214 24 x 11,5 180 1800 380 250 2250 180 450 280 2700 495 760 951 903 57 920 820 170
1250 1263 1311 1351 24 x 11,5 200 2000 450 250 2500 115 570 280 3000 625 855 1051 1003 57 1030 930 185
1400 1415 1465 1545 24 x 11,5 180 2000 please ask – – – please ask 315 2900 please ask 930 – – – – – –
1600 1587 1637 1717 32 x 11,5 225 2200 please ask – – – please ask 315 2900 please ask 1020 – – – – – –
Dimensions in mm
1) connecting dim. in acc. with DIN 24154 series 3 2) without motors. * Here further ducts are required, dim. a + a1 are therefore different
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
TWO-STAGE AXIAL SMOKE EXHAUST FANS
BVZAXN 12/56 SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
200/300/400°C – 120 MIN 114
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
V103
ca. 60 V105
V108
i.d.1
i.d.1
i.d.1
i.d.1
ca. 80 V112
V120
V130
V150
200 Installation
length For diffusors please see page 063
C G L4 L2
Øk
Wire guard
zxd L3
Size i.d.1 Øk ØD z x d1 Ø D1 C e f L2 L3 L4 C G
Inspection Inspection
hatch hatch
Inspection Inspection
hatch hatch
Terminal box Terminal box
355 3000 1,5 3,25 90 B14 160 630 1000 0,75 2,2 90 B5 200
2,2 4,6 90 B14 160 1,1 3,15 90 B5 200
1500/750 1,0/0,25 2,4/1,0 90 B14 160 1500 1,5 3,5 90 B5 200
3000/1500 1,5/0,37 3,7/1,0 90 B14 160 2,2 5,5 100 B5 250
3,0 7,1 100 B5 250
400 1500 1,1 2,80 90 B5 200 4,0 8,6 112 B5 250
3000 1,5 3,25 90 B5 200 1000/500 0,8/0,15 2,3/0,9 90 B5 200
2,2 4,6 90 B5 200 1,2/0,22 3,1/1,15 100 B5 250
3,0 6,7 100 B14 200 1500/750 2,5/0,6 5,6/2,2 100 B5 250
4,0 8,3 112 B14 200 3,8/1,0 8,1/3,4 112 B5 250
3000/1500 1,5/0,37 3,7/1,0 90 B5 200 5,5/1,4 11,4/4,3 132 B5 250
3,0/0,75 6,7/1,7 100 B14 200
4,1/1,0 8,8/2,1 112 B14 200 710 1000 1,1 3,15 90 B5 200
1,5 3,9 100 B5 250
450 1500 1,1 2,8 90 B5 200 2,2 5,4 112 B5 250
3000 3,0 6,7 100 B14 200 1500 3,0 7,1 100 B5 250
4,0 8,3 112 B14 200 4,0 8,6 112 B5 250
5,5 11 112 B14 200 5,5 11,4 132 B5 250
1500/750 1,0/0,25 2,4/1,0 90 B5 200 7,5 15,4 132 B5 250
3000/1500 3,0/0,75 6,7/1,7 100 B14 200 1000/500 1,2/0,22 3,1/1,15 100 B5 250
4,1/1,0 8,8/2,1 112 B14 200 1,85/0,33 4,6/1,6 112 B5 250
3,3/0,75 9,3/3,6 132 B5 250
500 1500 1,1 2,8 90 B5 200 1500/750 5,5/1,4 11,4/4,3 132 B5 250
1,5 3,5 90 B5 200 7,0/1,7 15,2/5,1 132 B5 250
3000 4,0 8,3 112 B5 250 11/3,0 24/9,5 160 B5 350
5,5 11 132 B5 250
7,5 14,6 132 B5 250 800 1000 2,2 5,4 112 B5 250
11 20,5 132 B5 250 3,0 7,4 132 B5 250
1000/500 0,48/0,08 1,6/0,58 90 B5 200 4,0 9,2 132 B5 250
1500/750 1,4/0,35 3,3/1,35 90 B5 200 1500 5,5 11,4 132 B5 250
3000/1500 3,0/0,75 6,7/1,7 100 B5 250 7,5 15,4 132 B5 250
6,0/1,5 13,3/3,2 132 B5 250 11 22 160 B5 350
7,8/2,0 16,2/4,1 132 B5 250 15 29,5 160 B5 350
1000/500 2,6/0,5 7,1/2,8 132 B5 250
560 100 0,75 2,2 90 B5 200 3,3/0,75 9,3/3,6 132 B5 250
1500 1,1 2,8 90 B5 200 4,4/1,0 11/4,4 132 B5 250
1,5 3,5 90 B5 200 1500/750 5,5/1,4 11,4/4,3 132 B5 250
1500 2,2 5,5 100 B5 250 7,0/1,7 15,2/5,1 132 B5 250
1000/500 0,8/0,15 2,3/0,9 90 B5 200 11/3,0 24/9,5 160 B5 350
1500/750 1,4/0,35 3,3/1,35 90 B5 200 14/3,5 30,5/11,4 160 B5 350
2,5/0,6 5,6/2,2 100 B5 250
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
TYP BZAXN 12/56 300°C - 120 Min
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany TECHNICAL LISTS (AVAILABLE MODELS) 117
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
900 1000 3,0 7,4 132 B5 250 1120 750 4,0 9,3 160 B5 350
4,0 9,2 132 B5 250 5,5 11,4 160 B5 350
5,5 12,7 132 B5 250 7,5 16,1 160 B5 350
7,5 15,7 160 B5 350 11 23,5 180 B5 350
1500 11 22 160 B5 350 1000 7,5 15,7 160 B5 350
15 29,5 160 B5 350 11 22 160 B5 350
18,5 36 180 B5 350 15 29,5 180 B5 350
22 43 180 B5 350 20 40 200 B5 400
30 52 200 B5 350 22 43 200 B5 400
1000/500 3,3/0,75 9,3/3,6 132 B5 250 30 57 225 B5 450
4,4/1,0 11/4,4 132 B5 250 1500 30 52 200 B5 400
6,3/1,5 15,7/5,4 160 B5 350 37 66 225 B5 450
8,8/2,2 20,5/7,0 160 B5 350 45 82 225 B5 450
1500/750 11/3,0 24/9,5 160 B5 350 55 (L) 97 250 B5 550
14/3,5 30,5/11,4 160 B5 350 75 (L) 132 280 B5 550
16/4,0 32,5/11,9 180 B5 350 1000/500 6,3/1,5 15,7/5,4 160 B5 350
20/5,5 39/16,2 180 B5 350 7,5/1,85 19/6,7 160 B5 350
28/7,0 52/16,2 200 B5 350 8,8/2,2 20,5/7,0 160 B5 350
1500/1000 12/3,5 24/9,5 160 B5 350 12,5/3,0 32,5/11 180 B5 350
15,5/3,3 34/11 200 B5 400
1000 1000 5,5 12,7 132 B5 250 18,5/4,4 40/13,3 200 B5 400
7,5 15,7 160 B5 350 22/5,5 41/13,3 225 B5 450
11 22 160 B5 350 27/6,6 51/18 225 B5 450
15 29,5 180 B5 350 1500/750 28/7,0 52/16,2 200 B5 400
1500 15 29,5 160 B5 350 33/8,0 60/19 225 B5 450
18,5 36 180 B5 350 37/9,2 69/24,5 225 B5 450
22 43 180 B5 350 39/9,5 (L) 72/21 225 B5 450
30 52 200 B5 350 44/11 (L) 78/24 225 B5 450
37 66 225 B5 450 49/12 (L) 84/23 250 B5 550 BVZAXN 12/56
45 82 225 B5 450 1500/750 68/17 (L) 125/43,5 280 B5 550
1000/500 4,4/1,0 11/4,4 132 B5 250 80/20 (L) 140/48 280 B5 550
6,3/1,5 15,7/5,4 160 B5 350
8,8/2,2 20,5/7,0 160 B5 350 1250 750 5,5 11,4 160 B5 350
12,5/3,0 32,5/11 180 B5 350 7,5 16,1 160 B5 350
1500/750 16/4,0 32,5/11,9 180 B5 350 11 23,5 180 B5 350
20/5,5 39/16,2 180 B5 350 15 31 200 B5 400
28/7,0 52/16,2 200 B5 350 18,5 37 225 B5 450
32/8,0 60/19 225 B5 450 1000 11 22 160 B5 350
37/10 69/24,5 225 B5 450 15 29,5 180 B5 350
20 40 200 B5 400
22 43 200 B5 400
30 57 225 B5 450
37 67 225 B5 450
45 (L) 81 280 B5 550
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
TYP BZAXN 12/56 300°C - 120 Min
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany TECHNICAL LISTS (AVAILABLE MODELS) 118
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Nominal current = appr. values for 400 V motors, brand EMOD. Brands ATB and
Loher marked (A) and (L) respectively.
It is important to check nominal current in case of other motor brands. • ATB motors
TWO-STAGE AXIAL SMOKE EXHAUST FANS
WITH DIRECT DRIVE AND OUTLET GUIDE VANES
BVZAXN 12/56 SERIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 300°C - 120 MIN 119
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
BVZAXN 12/56
BVZAXN 12/56
BVZAXN 12/56
BVZAXN 12/56
Accessory equipment:
• Galvanised fan
• Fan with special coating
• Extension casing without inspection hatch
• Inspection hatch
• Bellmouth inlet with flange
• Wire guard on bellmouth side
• Wire guard on extension casing (motor side)
• Flexible connector, inlet side*
• Flexible connector, outlet side*
• Matching flange inlet side*
• Matching flange outlet side*
• Angular wall ring with brackets*
• Set of mounting feet (2 pcs.)*
• Set of spring-type antivibration mounts*
• Brackets for vertical fan installation
• Diffuser with interior core*
• Flexible connector (diffuser outlet)*
• Wire guard (diffuser outlet)*
• Round silencer, TSR type*
• Outlet cone with wire guard
• Duct with self-activating damper
* Loosely supplied
Carryover
WALL-MOUNTING AXIAL SMOKE EXHAUST FANS
BWAXO SERIES
200 / 300 °C – 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 200/300°C - 120 MIN. 130
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
View „A“
Direction of flow
Wall opening
View "B"
(shown without louvre-type damper)
Flow velocity*c
Pressure losses of fan and shutoff damper sum up to the total
pressure increase needed for the sizing of complete fan units
Please refer to the characteristic (assuming free inlet / free outlet conditions).
curves on pages 053-055.
*For flow velocities please refer to the characteristic curves.
Weight
Size approx. [kg]
(without
motor)
330 25
40
900 65
450 90
Dimensions in mm
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
– 131 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Size
Weight of fan with accessories kg
Manufacturer: TLT-Turbo GmbH
Carryover
– 132 –
Unit price Total
Item
Qty. Description
No.
2 2
View „A“
Direction of flow
Wall opening
View "B"
(shown without louvre-type damper)
Flow velocity*c
Pressure losses of fan and shutoff damper sum up to the total pressure
increase needed for the sizing of complete fan units (assuming free
BWAXO
Weight
Size approx. [kg]
(without
motor)
900
Dimensions in mm
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
– 134 –
Unit price Total
Item
Qty. Description
No.
2 2
D C B
A1
E
A
F
C D N
Max.
Size N weight
~kg
588
668
742
932
1182
1332
up to motor size 132
Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
WALL MOUNTING CENTRIFUGAL SMOKE 200°C – 120 min.
EXHAUST FAN 300°C – 60 min.
BVW-R SERIES 400°C – 120 min.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
without motor enclosure 139
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
600°C – 120 MIN and cooling air duct.
E Free inlet B
wA
v
H
a
øG b
C D N
Max.
BVW
Size N weight
~kg
588
668
742
932
425
800 680 1182
425
800 680 1332
up to motor size 132
Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
WALL MOUNTING CENTRIFUGAL SMOKE 200°C – 120 min.
EXHAUST FAN 300°C – 60 min.
BVW-R SERIES 400°C – 120 min.
without motor enclosure
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN and cooling air duct.
140
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
D C B
A1
A
V
H
a b
øG
C D N
Casing orientations*
For dimensions please
refer to page 148.
A B C
Max.
Size N weight
~kg
588
668
742
932
425
800 680 1182
425 1332
800 680
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
ROOF MOUNTING CENTRIFUGAL SMOKE EXHAUST FAN
BVW-D SERIES
øG
E1
H
A
C D B
B3
e
M
350
B1 BVW
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
CENTRIFUGAL SMOKE EXHAUST FAN 200°C – 120 min.
BVW-R/B SERIES WITH INLET DUCT 300°C – 60 min.
MAIN DIMENSIONS 400°C – 120 min.
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
without motor enclosure 142
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
600°C – 120 MIN and cooling air duct.
øG
B
B
D
h
M K
L1
2 For dimensions please refer to page 148.
A C
H F D J K
Important!
Note special baseframe
dimensions (please ask).
I G E L B D
* View on motor enclosure.
Max.
Size weight
~kg
425
800 680
425
800 680
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
also available for
CENTRIFUGAL SMOKE EXHAUST FAN 200°C – 120 min.
BVW-R/B SERIES, FREE INLET 300°C – 60 min.
MAIN DIMENSIONS 400°C – 120 min.
without motor enclosure 143
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN and cooling air duct.
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
øG
B
B
M K
L2
For dimensions please refer to page 148.
A C
B D
D E F BVW
Max.
Size ø 2
weight
~kg
425
800 680 1200
425
800 680 1250
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-A/B SERIES WITH INLET DUCT
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 144
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
D C A1 A F
C
B
D
h
M K
L1
H F D J K
Important!
Note special baseframe
dimensions (please ask).
I G E L
* View on motor enclosure.
Max.
Size 1 weight
~kg
950
1150
1550
1650
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-A/B SERIES WITH ROUND DUCT CONNECTION
MAIN DIMENSIONS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 145
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
zxd
Øk
B
h
M K
L2
D E F
Max.
Size Øk z x d weight
~kg
356 8x10
395 8x10
850 438 12x10
541 12x10
674 16x12
751 16x12
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-AI/B SERIES WITH INLET DUCT
AND ACOUSTIC AND THERMAL ISULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 146
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
100 A1 A F
D C
100
C
B
D
100
h
M K
L1
Casing orientations*
Casing orientations * For dimensions
(inlet below)
please refer to
page 148
H F D J K
Important!
Note special baseframe
dimensions
(please ask).
I G E L
* View on motor enclosure.
Max.
Size 1 weight
~kg
950
1150
1550
1650
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FAN
BVW-AI/B SERIES WITH ROUND DUCT CONNECTION
AND ACOUSTIC AND THERMAL ISULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 147
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
zxd A F
Øk
B
100
h
M K
L2
D E F
Max.
Size Øk z x d weight
~kg
356 8x10
395 8x10
850 438 12x10
541 12x10
674 16x12
751 16x12
up to motor size 132 Dimensions in mm
motor sizes 160 and up
For planning and installation please also refer to our Installation, Operating and Maintenance Instructions (MBW).
CENTRIFUGAL SMOKE EXHAUST FANS
BVW SERIES
Connecting Dimensions - All Types
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 148
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
s = 6 mm
6
6
6
6
6
6
6
6
6
6
6
6
Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FAN
BVW SERIES
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 600°C – 120 MIN 149
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Ø d2 i.d.
a/b
a/b
90 Installation length
BVW
Please fit flexible connectors with precisions, observing the installation length.
Dimensions
Size for for L (600°C) L (200 - 400°C) Ø d2 i.d.
a b a b
315 252 632 102 202 90 200 321
355 252 712 102 202 90 200 360
400 282 802 102 202 90 200 403
500 357 1002 142 317 90 200 506
630 452 1252 142 317 90 200 637
710 502 1402 142 317 90 200 714
Screw internally
during
Installation
M 8x16
50
ca. 60
e(e1)
h(h1)
e(e1)
ca. 80
Dimensions in brackets apply to
installation on spring-type
antivibration mounts. Detailed
drawing showing installation jig
hole patterns available on request.
Dimensions in mm
CENTRIFUGAL TYPE SMOKE EXHAUST FANS
BVW-A · BVW-R · BVW-D SERIES
Flange dia
3000 rpm
Motor size
output current at
BVW-A
1800 400 V-50 Hz
Pressure losses BVW-R
BVW-D rpm kW approx A BVW-A
BVW-R BVW-R
––– Inlet box BVW-D **
- - - BVW-D damper
1600 ....... BVW-A or 315/30-6 910 0,55 1,6 80 200
R damper 315/30-4 1390 0,55 1,4 80 200
315/30-2 2880 4,4 9,5 112 250 112 92 114
315/30-2/4 2890/1440 4,1/1,0 8,8/2,1 112 250
1400 315/30-4/8 1400/670 0,7/0,18 2,0/0,8 80 200
␦
= 1,2 kg/m3
315/30-4/6/8 1430/950/700 1,0/0,33/0,26 2,4/1,05/0,95 100 250
t = 20°C
1200
800
600
Speed Relative acoustic power level
Acoustic level Vmax.
1500 rpm Octave center frequency Hz
400 [rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
670 74 65 45 68 71 64 63 60 56 51 46
-4
920 80 72 52 73 77 70 68 67 65 61 56
1000 rpm
200 1390 87 82 62 80 79 84 76 75 76 72 68
2880 101 98 78 93 92 90 96 89 90 92 88
-6
LpA: Average sound pressure level at 4 m distance (free field)
Measuring surface S = 101 (m2)
1000 2000 3000 4000 5000 6000 7000 8000 9000
Measuring surface level: Ls = 20 (dB)
Volume flow V m3/h 씮
output current at
1500 rpm BVW-A
600 400 V-50 Hz
BVW-R
Pressure losses
BVW-D rpm kW approx A BVW-R BVW-R
––– Inlet box BVW-A
BVW-D **
550 - - - BVW-D damper
....... BVW-A or 355/30-6 910 0,55 1,6 80 200
-4 R damper 355/30-4 1410 1,5 3,6 90 200
500
355/30-4/8 1400/680 1,4/0,35 3,3/1,35 90 200
355/30-4/6 1410/950 1,1/0,37 2,8/1,35 90 200
450 355/30-4/6/8 1430/950/700 1,0/0,33/0,26 2,4/1,05/0,95 100 250 136 125 136
␦
= 1,2 kg/m3
t = 20°C
400
300
200
-6 Speed Relative acoustic power level
Acoustic level Vmax.
Octave center frequency Hz
150
750 rpm [rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
420 66 58 38 63 60 60 56 52 47 42 37
100
-8 670 77 69 49 71 74 67 66 64 61 56 51
910 83 76 56 76 80 73 71 71 69 65 60
50 1410 91 86 66 84 82 87 80 79 80 77 72
Flange dia
1500 rpm
Motor size
750 output current at
BVW-A
400 V-50 Hz
Pressure losses BVW-R
kW approx A BVW-R BVW-R
700 BVW-D rpm BVW-A
––– Inlet box BVW-D **
- - - BVW-D damper
650 ....... BVW-A or 400/30-6 910 0,55 1,6 80 200
R damper 400/30-4 1410 1,5 3,6 90 200
400/30-4/8 1400/680 1,4/0,35 3,3/1,35 90 200
600
400/30-4/6 1405/930 1,6/0,6 3,9/1,8 100 250
400/30-4/6/8 1440/965/700 1,5/0,6/0,37 3,5/1,8/1,45 100 250 170 165 202
550 ␦
= 1,2 kg/m3
t = 20°C
500
450
* for motor size 100
** BVW-R with inlet duct
400
-4
350
1000 rpm
300
250
Speed Relative acoustic power level
Acoustic level Vmax.
200 Octave center frequency Hz
750 rpm -6 Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
[rpm]
150
-8 420 72 61 41 70 63 63 59 56 52 47 42
670 80 72 52 74 77 70 69 67 65 60 55
100
910 86 79 59 79 83 76 74 74 73 69 64
1400 94 89 69 87 85 90 82 81 83 81 77
50
1500 rpm
output current at
1200 BVW-A
Pressure losses 400 V-50 Hz
BVW-R
––– Inlet box BVW-D rpm kW approx A BVW-A
BVW-R BVW-R
BVW-D **
1100 - - - BVW-D damper
....... BVW-A or 500/30-6 910 1,5 4,3 100 250
R damper 500/30-4 1420 5,5 11,5 132 250
1000 500/30-4/8 1420/700 5,5/1,4 11,4/4,3 132 250
500/30-4/6 1460/955 6,0/2,0 12,5/5,4 132 250 270 230 282
␦ 500/30-6/8/12 965/720/470 1,6/0,8/0,33 4,7/2,9/1,9 132 250
900 = 1,2 kg/m3
t = 20°C
800
-4
* for motor size 132
700 ** BVW-R with inlet duct
600
1000 rpm
500
400
Speed Relative acoustic power level
-6 Acoustic level Vmax.
750 rpm Octave center frequency Hz
300
[rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
-8
420 75 69 49 71 68 69 67 64 60 55 50
200
690 87 80 60 80 84 76 76 75 74 69 65
910 92 86 66 85 89 82 80 80 81 77 73
100 1420 100 96 76 93 91 96 88 87 90 89 85
Flange dia
Motor size
output current at
BVW-A
2000 400 V-50 Hz
Pressure losses BVW-R
kW approx A BVW-R BVW-R
––– Inlet box BVW-D rpm BVW-A
BVW-D **
- - - BVW-D damper
1800 ....... BVW-A or 630/25-6 940 3,0 7,0 132 300
1500 rpm R damper 630/25-4 1470 11 22 160 300
630/25-4/8 1460/710 10/3,0 22/10 160 300 460 385 474
1600
630/25-6/12 975/480 3,3/0,75 9,3/3,6 132 300
630/25-6/8/12 970/735/475 3,0/1,5/0,6 7,6/4,6/2,8 132 300
␦
= 1,2 kg/m3
1400 t = 20°C
1000
-4
800
1000 rpm Acoustic levels on outlet side (free-field conditions)
Additionally available pressure ⌬pt Pa 씮
1500 rpm BVW 630/30 Model Speed Motor Nominal Flange dia
Max. weight approx
Motor size
output current at
BVW-A
2000 400 V-50 Hz
Pressure losses BVW-R
kW approx A BVW-R BVW-R
––– Inlet box BVW-D rpm BVW-A
BVW-D **
- - - BVW-D damper
1800 ....... BVW-A or 630/30-6 940 5,5 12,7 132 300
R damper 630/30-4 1470 18,5 35 180 300
630/30-4/8 1460/710 20/5,5 39/16,2 180 300 460 385 474
1600
630/30-6/12 975/480 6,3/1,5 15,7/5,4 160 300
␦ 630/30-6/8/12 970/735/475 6,0/3,0/1,5 11,9/9,5/4,4 160 300
= 1,2 kg/m3
t = 20°C
1400
BVW
1000
1000 rpm
800
Acoustic levels on outlet side (free-field conditions)
Additionally available pressure ⌬pt Pa 씮
400 440 86 78 58 83 77 75 75 73 71 67 62
720 94 88 68 87 90 83 82 81 82 79 74
940 99 94 74 92 95 89 86 86 88 87 82
-8
200 1470 107 103 83 99 98 103 95 93 97 98 95
Flange dia
Motor size
1500 rpm output current at
BVW-A
Pressure losses 400 V-50 Hz
1800 BVW-R
kW approx A BVW-R BVW-R
––– Inlet box BVW-D rpm BVW-A
BVW-D **
- - - BVW-D damper
....... BVW-A or 710/30-6 940 5,5 12,7 132 300
1600 R damper
710/30-4 1470 18,5 36 180 300
710/30-4/8 1460/710 20/5,5 39/16,2 180 300 570 475 605
710/30-6/12 975/475 6,3/1,5 14/4,8 160 300
␦
1400 = 1,2 kg/m3 710/30-6/8/12 970/725/475 7,5/4,0/1,85 16,2/10/7,1 180 300
t = 20°C
1200
800
1000 rpm
600
Speed Relative acoustic power level
Acoustic level Vmax.
Octave center frequency Hz
750 rpm
400 [rpm] Lw (dB) LwA (dB) LpA (dB) 63 125 250 500 1000 2000 4000 8000
-6 475 91 82 62 89 83 81 80 77 73 68 63
-8 715 98 90 70 91 95 88 87 86 83 78 73
200 950 104 99 79 97 101 94 92 94 93 88 83
1470 113 109 89 104 103 109 101 102 104 100 96
Frequency Hz
Total sound pressure level LW dB
Weight of fan with accessories kg
Carryover
– 156 –
Unit price Total
Item
Qty. Description
No.
2 2
Accessory equipment
* Loosely supplied
Carryover
– 157 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Carryover
– 158 –
Unit price Total
Item
Qty. Description
No.
2 2
Accessory equipment
• Inlet box
• Inlet duct
* Loosely supplied
– 159 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Accessory equipment:
* Loosely supplied
CENTRIFUGAL SMOKE EXHAUST FANS
PRODUCT RANGE
TECHNICAL DESCRIPTION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 161
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
130 B Optional or to be H
provided by installer:
E G
thermal and acoustic insulation
Ødh6
for max. motor size
C
180
h
LG90° (RD90°)
Gmax. J
Lmax. K
Casing position LG0¡ (RD0¡)* LG 180¡ (RD 180¡)* LG 270¡ (RD 270¡)*
B
A E
A
E
A
B
B
E
B Optional or to be H
130
provided by installer: G
E thermal and acoustic insulation
Ødh6
for max. motor size
C
180
h
LG90° (RD90°)
Gmax. J
Lmax. K
Casing position LG0¡ (RD0¡)* LG 180¡ (RD 180¡)* LG 270¡ (RD 270¡)*
B
A E
A
E
A
B
B
E
BV-REH
200 B H
Optional or to be
E provided by installer: G
thermal and acoustic insulation
Ødh6
for max. motor size
C
200
h
LG90° (RD90°)
Gmax. J
Lmax. K
Casing position LG0¡ (RD0¡)* LG 180¡ (RD 180¡)* LG 270¡ (RD 270¡)*
B
E
A A
E
A
B
B
E
Inspection hatch The inspection hatch meets accident Acoustic and thermals
Arranged in accordance with casing prevention rules. It can only be ope- insulation for centrifugal smoke
orientation. Available in two versions: ned by using tools. exhaust fans
B The position of this hatch depends Mineral fibre mats, stitched with
A
on casing orientation. galvanized wire onto galvanized
A Standard version, fitted with self- wire netting on one side
tapping screws. Rigid support structure, 120 mm
B Industrial version with handle, shell spacing
attached via backwelded nuts Outer protective shell consisting of
and hexagonal head screws. 1.0 mm gauge smooth sheet steel,
galvanized on both sides. For out-
door installation, an additional pro-
tective lacquer coating is applied
(for extra charge please see tariff).
Connections are designed to facili-
Drain connection
tate dismantling and refitting. Hori-
(Please specify casing orientation in
zontally and vertically split versions
purchase order).
are available (for extra charge
Fan sizes up to 1000:
please see tariff).
R 1/2” female thread connection
Fan sizes of 1120 and higher: Technical details based on DIN
R1” female thread connection 18421 and DIN 4102 standard spe-
Fitted at lowest point of casing. cifications, respectively.
Damping effect: approx. 12 dB
(acoustic emission from fan ca-
sing)
Spring-type version
Ø 12
zxf
f/g
d
f
100
400 362 326 282 - 163 582 546 502 3x125 85,5 334
450 397 361 317 1x125 118 642 606 562 3x125 115,5 362
500 437 401 357 1x125 138 712 676 632 3x125 150,5 395
560 482 446 402 1x125 160,5 792 756 712 5x125 65,5 432
630 532 496 452 3x125 60,5 882 846 802 5x125 110,5 474
710 582 546 502 3x125 85,5 982 946 902 5x125 160,5 521
800 642 606 562 3x125 115,5 1082 1046 1002 7x125 85,5 567
900 752 702 632 3x125 163,5 1242 1192 1122 7x125 158,5 623
1000 832 782 712 5x125 78,5 1372 1322 1252 9x125 98,5 684
1120 922 872 802 5x125 123,5 1124 1072 1002 7x125 98,5 567
1250 1022 972 902 5x125 173,5 1242 1192 1122 7x125 158,5 623
1400 1122 1072 1002 7x125 98,5 1372 1322 1252 9x125 98,5 684
1600 1242 1192 1122 7x125 158,5 1522 1472 1402 9x125 173,5 754
Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C-120 MIN 167
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
a
❶ Matching flange ❷ Flexible connector,
rectangular
c
e1
e1 z1 x t1
e
x
zxt
d
b
ØD
w
*
x
e
s
L
BV-REH
Size a c g z1 x t1 e1 b d f zxt e w x ØD s L ❶ ❷
appr. (kg) appr. (kg)
400 362 326 282 – 163 582 546 502 3 x 125 85,5 22 40 12 4 130 8,0 4,0
450 397 361 317 1 x 125 118 642 606 562 3 x 125 115,5 22 40 12 4 130 8,5 5,0
500 437 401 357 1 x 125 138 712 676 632 3 x 125 150,5 22 40 12 4 130 9,0 5,0
560 482 446 402 1 x 125 160,5 792 756 712 5 x 125 65,5 22 40 12 4 130 10 6,0
630 532 496 452 3 x 125 60,5 882 846 802 5 x 125 110,5 22 40 12 4 130 12 6,0
710 582 546 502 3 x 125 85,5 982 946 902 5 x 125 160,5 22 40 12 4 130 12,5 7,0
800 642 606 562 3 x 125 115,5 1082 1046 1002 7 x 125 85,5 22 40 12 4 130 13 8,0
900 752 702 632 3 x 125 163,5 1242 1192 1122 7 x 125 158,5 35 60 12 6 130 15 20
1000 832 782 712 5 x 125 78,5 1372 1322 1252 9 x 125 98,5 35 60 12 6 130 17 23
1120 922 872 802 5 x 125 123,5 1124 1072 1002 7 x 125 98,5 35 60 12 4 200 18,5 7,0
1250 1022 972 902 5 x 125 173,5 1242 1192 1122 7 x125 158,5 35 60 12 6 200 20 12
1400 1122 1072 1002 7 x 125 98,5 1372 1322 1252 9 x 125 98,5 35 60 12 6 200 23 13
* Burgert-Type Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
ACCESSORIES
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 400°C-120 MIN 168
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
C
❶ Matching flange ❷ Flexible connector,
B round
z x ød
s
L
Size ØA ØB ØC Z x ød s L ❶ ❷
appr. (kg) appr. (kg)
400 403 438 464 12 x 9,5 6 180 2,0 5,2
450 452 487 513 12 x 9,5 6 180 2,0 5,8
500 506 541 567 12 x 9,5 6 180 2,0 6,6
560 568 605 639 16 x 11,5 6 180 3,0 8,2
630 637 674 708 16 x 11,5 6 180 3,5 9,2
710 714 775 814 16 x 14 8 180 7,0 16,5
800 804 861 904 24 x 14 8 180 8,0 19,2
900 904 958 1004 24 x 14 8 180 9,0 21,3
1000 1005 1067 1105 24 x 14 8 180 10 23,8
1120 1005 1067 1105 24 x 14 8 200 10 25,8
1250 1125 1200 1245 32 x 18 10 200 17 26
1400 1255 1337 1375 32 x 18 10 200 19 40
Dimensions in mm
CENTRIFUGAL SMOKE EXHAUST FANS
BV-REH SERIES
ACOUSTIC DATA
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 169
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Acoustic level Starting from this value, the A-weighted acoustic power emitted from the fan inlet or outlet
power level LWA and the relative acoustic power opening, respectively. The values given were
The total acoustic power level Lwvent of an axial- taken from measurements as per EN 25136
level LW rel. can be determined using the tables
flow fan can be obtained directly from the (formerly DIN 45 635, Part 9) duct testing method.
below. These values are available as the acoustic
characteristic data sheets for each operating
power emitted into the duct and as the acoustic
point.
Acoustic power level emitted into the duct Acoustic power emitted from the fan inlet or outlet opening
The level of acoustic power an axial-flow fan emits into the ducting is To determine the sound levels at a given installation site, it is usually
used for calculating the sound power characteristics of downstream necessary to know the level of acoustic power emitted from the fan's
systems, e.g., silencers. The levels are calculated as follows: inlet or outlet opening. The tables below are based on the outlet
reflection pattern assumed in VDI 2081, Case 2.
Lwvent. (dB) = total acoustic power emitted by the fan, (please see
respective characteristic curve sheets) LwA op. (dB) = A-weighted level of acoustic power emitted from the
fan's opening, expressed by the equation
LwA vent. (dB) = A-weighted acoustic power level, according to the
equation LwA op. = Lwvent – portion 2.1 (dB)
LwA vent. = Lwvent – portion 1.1 (dB) Lwrel op.(dB) = relative level of acoustic power emitted from the fan's
opening, expressed by the equation
Lwrel vent. (dB) = relative acoustic power level as expressed by the
equation Lwrel op. = Lwvent – portion 2.2 (dB)
LwA rel vent. = Lwvent – portion 1.2 (dB) LW Op. (dB) = Unweighted (linear) level of acoustic power emitted
from the fan's opening, expressed by the equation
LW Op. = Lwvent – portion 2.3 (dB)
Size
Ventilator- Drehzahl
Fan Anteil
Speed Portion Anteil 1.2 1.2
Portion beiatOktavmittenfrequenz [Hz]
mid-octave frequency [Hz] Size
Ventilator- Drehzahl Anteil
Fan Speed Portion Anteil 2.2 2.2
Portion beiatOktavmittenfrequenz [Hz]
mid-octave frequency [Hz] Anteil
Portion
Baugröße [min -1 Baugröße [min -1
[rpm] ] 1.1
1.1 63
63 125
125 250
250 500
500 1000
1000 2000
2000 4000
4000 8000
8000 [rpm]] 2.1
2.1 63
63 125
125 250
250 500
500 1000
1000 2000
2000 4000
4000 8000
8000 2.3
2.3
1800 7 6 8 4 11 12 15 20 25 1800 7 14 11 5 11 12 15 20 25 2
800 630 13 5 3 10 16 20 25 30 35 800 630 13 12 6 10 16 20 25 30 35 4
800 11 5 3 10 13 18 22 27 33 800 12 12 6 10 13 18 22 27 33 3
1000 10 5 3 9 12 16 20 25 30 1000 10 12 5 8 12 16 20 25 30 2
1250 8 6 8 4 10 14 18 22 28 1250 8 13 11 5 10 14 18 22 28 2
1600 7 6 8 4 11 12 15 20 25 1600 7 13 11 4 11 12 15 20 25 2
900 560 13 2 7 11 16 20 24 30 35 900 560 14 7 9 11 16 20 24 30 35 4
710 12 5 3 10 14 17 22 27 32 710 12 11 6 10 14 17 22 27 32 3
900 10 5 3 10 13 15 20 25 30 900 10 11 5 10 13 15 20 25 30 2
1120 9 5 3 10 12 14 18 22 28 1120 9 12 5 10 12 14 18 22 28 2
1400 7 6 8 4 11 12 15 20 25 1400 7 12 10 5 11 12 15 20 25 2
1000 500 13 2 7 11 16 20 24 30 35 1000 500 14 6 9 11 16 20 24 30 35 3
630 12 5 3 10 14 17 22 27 32 630 12 10 5 10 14 17 22 27 32 3
800 10 5 3 10 13 15 20 25 30 800 10 10 5 10 13 15 20 25 30 2
1000 9 5 3 10 12 14 18 22 28 1000 9 11 4 10 12 14 18 22 28 2
1250 7 6 8 4 11 12 15 20 25 1250 7 11 10 4 11 12 15 20 25 1
1120 450 12 1 9 12 14 16 21 26 31 1120 450 12 4 10 12 14 16 21 26 31 2
560 10 2 9 12 13 14 19 24 29 560 10 4 10 12 13 14 19 24 29 2
710 8 10 2 10 13 13 16 21 26 710 9 13 3 10 13 13 16 21 26 1
900 7 10 2 10 12 11 14 19 24 900 7 13 3 10 12 11 14 19 24 1
1120 6 10 2 11 12 11 12 16 21 1120 6 13 3 11 12 21 12 16 21 –
1250 400 12 1 9 12 14 16 21 26 31 1250 400 12 5 10 12 14 16 21 26 31 2
500 10 2 9 12 13 14 19 24 29 500 10 4 10 12 13 14 19 24 29 2
630 9 2 9 12 13 13 16 21 26 630 9 3 10 12 13 13 16 21 26 1
800 7 10 2 10 13 11 14 19 24 800 7 12 3 11 13 11 12 16 21 1
1000 6 10 2 11 13 11 12 16 21 1000 6 13 3 11 13 11 12 16 21 –
1400 355 12 1 9 12 14 16 21 26 31 1400 355 12 4 10 12 14 16 21 26 31 2
450 10 2 9 12 13 14 19 24 29 450 10 4 10 12 13 14 19 24 29 2
560 9 2 9 12 13 13 16 21 26 560 9 3 10 12 13 11 14 19 24 1
710 7 10 2 10 13 11 14 19 24 710 7 12 3 10 13 11 14 19 24 1
900 6 10 2 11 13 11 12 16 21 900 6 12 3 11 13 11 12 16 21 –
Note: Portions 1.1/ 1.2 /2.1/ 2.2/ 2.3 to be taken frome the above spreadsheets
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
Moment of inertia J = 0,13 kgm2 Number of blades z = 9 Moment of inertia J = 0,19 kgm2 Number of blades z = 9
Impeller diameter D2 = 398 mm Free discharge area F = 0,141 m2 BV-REH 400 Impeller diameter D2 = 447 mm Free discharge area F = 0,178 m2 BV-REH 450
Efficiency =
0,63
t = 20°C
0,72
0,63
0,76
t = 20°C
0,72
❶ ␦
= 1,2 kg/m3
0,76
nmax. = 3740 rpm
4500 0,80
4500 ❶ nmax. = 3330 rpm ␦
= 1,2 kg/m3
0,80
4000 ❷ nmax. = 3600 rpm 4000
0,81
❷ nmax. = 3200 rpm
0,81
3550 105 3550
106
3150
0,76
3150
]
]
[dB
[dB
0,76
2800 2800
t
ven
102 2500
2500 0,64
103
w
w
l L
l L
0,64
2240 2240
leve
leve
2000 99 2000 100
wer
wer
1800 1800
0,48
o
0,48
o
0,61
tic p
0,70
tic p
1600 1600
0,61
0,74
0,70
97
0,74
ous
1400
0,78
1400
ous
98
0,78
l ac
l ac
1250 1250
0,79
94
Tota
4000 83
0,79
Tota
1120 1120 95 3550 83
1000 1000
0,74
0,74
900 3550 74 900 3150 74
91
800 800 92
0,62
3150 66
0,62
710 710 2800 66
630 88 630
2800 58 89
560 560 2500
0,46
58
0,46
500 500
450 85 2500 52 450 2240 52
82 86
400 400 83
Overall pressure increase ⌬pt1 [Pa] ➞
1 400
1 600
1 800
2 000
2 240
2 500
2 800
3 150
3550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
Volume flow rate* Volume flow rate*
V [m3/h]
V [m3/h]
Volume flow rate*
2,8 0,4
3,15 0,45
3,55 0,5
4,0 0,56
4,5 0,63
5,0 0,71
5,6 0,8
6,3 0,9
7,1 1,0
8,0 1,12
9,0 1,25
10 1,4
11,2 1,6
12,5 1,8
14 2,0
16 2,24
18 2,5
20 2,8
22,4 3,15
25 3,55
28 4,0
35,5 4,5
2,24 0,315
2,5 0,355
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pd [Pa] pd [Pa]
❶ nmax. if only used in case of fire / ❷ nmax. if used for ventilation (continuous service). Do not select in grey screened fields
Moment of inertia J = 0,39 kgm2 Number of blades z = 9 Moment of inertia J = 0,61 kgm2 Number of blades z = 9
Impeller diameter D2 = 501 mm Free discharge area F = 0,225 m2 BV-REH 500 Impeller diameter D2 = 562 mm Free discharge area F = 0,286 m2 BV-REH 560
5000 Efficiency =
0,63
Efficiency = 5000
0,63
t = 20°C
0,72
t = 20°C
0,72
0,76
0,76
4000 4000
❷ nmax. = 2860 rpm ❷ nmax. = 2550 rpm
0,82
0,82
0,76
0,76
[dB
2800 2800
Tip speed u2 [m/s]
t
ven
0,64
Lw
0,64
2240 2240
l
leve
el
2000
r lev
1800 1800
owe
0,48
0,48
c po
1600 1600
0,61
tic p
0,61
0,70
0,70
ti
0,74
0,74
1400
ous
99 1400 100
ous
0,78
0,78
l ac
1250 1250
l ac
0,80
0,80
Tota
96 1120 97
1000 1000
0,74
0,74
500 500
450 87 2000 52 450 88 1800 52
400 84 400 85
Overall pressure increase ⌬pt1 [Pa] ➞
2 240
2 500
2 800
3 150
3 550
4 000
4 500
5 000
5 600
6 300
7 100
8 000
9 000
10 000
11 200
12 500
14 000
16 000
18 000
20 000
22 400
25 000
28 000
31 500
V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pd [Pa] pd [Pa]
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
Moment of inertia J = 1,26 kgm2 Number of blades z = 9 Moment of inertia J = 2,0 kgm2 Number of blades z = 9
Impeller diameter D2 = 631 mm Free discharge area F = 0,362 m2 BV-REH 630 Impeller diameter D2 = 708 mm Free discharge area F = 0,44 m2 BV-REH 710
Efficiency = Efficiency =
0,63
0,63
5000 t = 20°C 4000 t = 20°C
0,72
0,72
0,76
0,76
❶ nmax. = 2360 rpm ❶ nmax. = 1750 rpm
4500 ␦ 3550 ␦
= 1,2 kg/m3 = 1,2 kg/m3
0,80
0,80
4000 3150
❷ nmax. = 2270 rpm ❷ nmax. = 1700 rpm
0,82
0,82
3550 109 2800 108
3150 2500
]
]
[dB
[dB
0,76
0,76
2800 2240
t
t
ven
ven
w
w
l L
0,64
l L
0,64
2240 1800
leve
leve
wer
wer
1800 1400
0,48
0,48
o
o
tic p
tic p
1600 1250
0,61
0,61
0,70
0,70
0,74
0,74
ous
ous
0,78
0,78
l ac
l ac
1250 1000
0,80
0,80
Tota
Tota
0,74
0,74
0,62
0,62
0,46
0,46
500 400
450 89 1600 52 355 88 1250 47
400 86 315 85
V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
35,5
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pd [Pa] pd [Pa]
❶ nmax. if only used in case of fire / ❷ nmax. if used for ventilation (continuous service). Do not select in grey screened fields
Moment of inertia J = 3,47 kgm2 Number of blades z = 9 Moment of inertia J = 7,16 kgm2 Number of blades z = 9
Impeller diameter D2 = 794 mm Free discharge area F = 0,55 m2 BV-REH 800 Impeller diameter D2 = 891 mm Free discharge area F = 0,70 m2 BV-REH 900
Efficiency =
0,64
Efficiency =
0,63
t = 20°C
0,73
t = 20°C 4000
0,72
4000
0,77
0,76
3550
0,80
2500
0,77
0,76
[dB
]
[dB
2240 2240
Tip speed u2 [m/s]
2000 107
t
106
ven
2000
Lw
0,65
0,64
w
1800 1800
l L
el
r lev
1600
leve
1400 1400
r
0,49
0,48
owe
tic p
0,62
1250
0,61
0,71
1250
0,70
tic p
0,75
0,74
1120
0,79
0,78
ous
BV-REH
l ac
1000 1000
l ac
0,81
0,80
Tota
800 800
0,75
0,74
400 400
355 89 1120 47 355 90 1000 47
315 86 315 87
Overall pressure increase ⌬pt1 [Pa] ➞
V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
pd [Pa] pd [Pa]
CENTRIFUGAL SMOKE EXHAUST FANS
REH SERIES - SINGLE INLET SINGLE WIDTH
Moment of inertia J = 11,3 kgm2 Number of blades z = 9 Moment of inertia J = 19,4 kgm2 Number of blades z = 8
Impeller diameter D2 = 1000 mm Free discharge area F = 0,88 m2 BV-REH 1000 Impeller diameter D2 = 1120 mm Free discharge area F = 0,80 m2 BV-REH 1120
Efficiency =
0,64
4000 0,77
❶ nmax. = 1240 min. ␦ ␦
3550 = 1,2 kg/m3 4500 = 1,2 kg/m3
❷ nmax. = 1180 min. 0,81
3150 4000 Efficiency =
0,63
0,83
0,69
0,73
2800 3550
0,77
111
0,82
3150 ❶ nmax. = 1120 rpm
0,85
2500
[dB
0,77
0,86
2240 2800 ❷ nmax. = 1120 rpm
0,83
t
ven
0,65
l L
0,81
1800 2240
]
[dB
leve
2000 114
1600 105
t
ven
wer
1400 1800
0,49
0,75
o
l L
111
tic p
1600
0,62
1250
0,71
leve
0,75
1120
0,79
wer
l ac
1000 1250
0,81
o
Tota
1400 74 1120
tic p
900 100 1120 108 66
1000
ous
800
0,75
0,62
1250 66 1000
l ac
900 58
0,68
710
0,72
0,76
97
Tota
0,81
630 800 105
0,84
0,63
0,85
560
0,82
500 94 630
450 1000 52 560 800 47
0,80
0,47
101
400 500
355 91 900 47 450 710 42
0,74
315 88 400 98
Overall pressure increase ⌬pt1 [Pa] ➞
V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,0
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,8
3,55
4,5
5,6
7,1
9,0
11,2
14
18
22,4
28
35,5
45
56
71
90
112
140
180
224
280
355
450
560
2,5
3,15
4,0
5,0
6,3
8,0
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
pd [Pa] pd [Pa]
❶ nmax. if only used in case of fire / ❷ nmax. if used for ventilation (continuous service). Do not select in grey screened fields
Moment of inertia J = 30 kgm2 Number of blades z = 8 Moment of inertia J = 63 kgm2 Number of blades z = 8
Impeller diameter D2 = 1250 mm Free discharge area F = 1,01 m2
BV-REH 1250 Impeller diameter D2 = 1400 mm Free discharge area F = 1,25 m2 BV-REH 1400
5000 t = 20°C 5000 t = 20°C
␦
4500
␦
= 1,2 kg/m3 4500 = 1,2 kg/m3
4000 Efficiency = 4000 Efficiency =
0,63
0,69
0,63
0,69
0,73
0,73
0,77
3550 3550
0,77
0,85
3150 3150
0,85
0,86
2500 2500
116
0,81
115 2240
0,81
2240
]
[dB
2000
]
2000
[dB
t
ven
1800 1800
t
0,75
ven
Lw
0,75
112 113
1600 1600
Lw
el
1400 74 74
el
r lev
1250
owe
1250
owe
1120
tic p
1000 1000
ous
0,62
ous
0,62
0,68
0,72
0,68
0,72
0,76
0,76
0,81
l ac
800
Tota
0,81
800 107
0,84
106
0,84
Tota
710 710
0,85
710 800 52 52
0,85
0,82
0,82
630 630
560 710 47 560 630 47
0,80
103
0,80
102
500 500
450 630 42 450 560 42
0,74
0,74
99
355 560 37 355 500 37
315 315
96 93 280 97 450
280 90 500 33 94 91
33
250 250
224 450 39 224 400 39
* values rounded to standard figures
V [m3/s] V [m3/s]
Flow velocity* Flow velocity*
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
2,24
2,5
2,8
3,15
3,55
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c2 [m/s] c2 [m/s]
Dynamic pressure* Dynamic pressure*
2,8
3,55
4,5
5,6
7,1
9,0
11,2
14
18
22,4
28
35,5
45
56
71
90
112
140
180
224
280
355
450
560
2,8
3,55
4,5
5,6
7,1
9,0
11,2
14
18
22,4
28
35,5
45
56
71
90
112
140
180
224
280
355
450
560
pd [Pa] pd [Pa]
– 173 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
BV-REH
Carryover
– 174 –
Unit price Total
Item
Qty. Description
No.
2 2
Specifications
Volume flow m3/h
Temperature 20°C
Total pressure increase Pa
Dynamic pressure Pa
Fan speed rpm
Efficiency %
Shaft power input requirement kW
Total acoustic pressure level Lw dB
Motor output kW
Motor speed rpm
Motor current rating A
Voltage V
Frequency Hz
Weight kg
Type: BV-REH
Accessory equipment:
• Standard three-phase motor, style B3 with terminal box,
protection class IP55 / ISO Cl. F, motor protection
• Flexible connector for 400°C (inlet/outlet)
• Flat flange (inlet)
• Angular frame (outlet)
• Spring-type antivibration mounts for 400°C
• Inspection hatch
• Condensate drain
• Lubricant line (bearings re-greasable in operation)
• V-belt drive (narrow type V-belt)
• V-belt guard
• RPM measuring orifice in V-belt guard
• Fan suitable for outdoor installation
• Thermal and acoustic insulation of fan casing
Carryover
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
MAIN DIMENSIONS - WITHOUT INSULATION
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany
620°C – 90 MIN 175
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
i L
a1 e r2 b1
r1
ød1
H
q1 q2 v1 v2
i L
l r2 b1
a1
r1
ød1
H
q1 q2 v1 v2
B1/B3
B/B2
B1
zxL
zxL
B
ø d1
Ød
z1 x L L
B3
B2
Length of Flexible Connector: „L“
up to size 450 = 150 mm
as from size 500 = 200 mm
z x ød
d1
ø d1
øD
ø d1
øk
k
L
a1 / b1
Birds mesh
100
BVRA
CENTRIFUGAL SMOKE EXHAUST FANS
BVRA SERIES
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,0225 kgm2 BVRA 180 Number of blades: 8, moment of inertia: 0,0325 kgm2 BVRA 200
= =
0
0
4000 4000
0,6
0,6
3
0,6
0,6
6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
Fan speed [rpm]*
3
0,7
0,7
Tip speed [m/s]
6
Please ask 0,7 Please ask
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
3
1800 1800
0,6
0,6
1600 6300 76,5 1600 5600 76,5
1400 1400
1250 5600 66,9 1250 5000 66,9
105 105
1120 1120
1000 5000 59,4 1000 4500 59,4
103 103
900 900
]
]
[dB
[dB
800 4500 52,7 800 4000 52,7
100 100
710 710
LW
LW
Total pressurre difference 䉭pt [Pa] 씮*
ent
98 98
560 560
irem
irem
500 3550 42,4 500 3150 42,4
equ
equ
95 95
450 450
ut r
ut r
400 3150 37,6 400 2800 37,6
93 93
inp
inp
355 355
er
er
315 2800 33 315 2500 33
pow
pow
90 90
280 280
aft
aft
250 2500 29,4 250 2240 29,4
88 88
Sh
Sh
224 Power requirement 224 Power requirement
200 at shaft: 2240 26,4 200 at shaft: 2000 26,4
· · 䉭pt 85 · · 䉭pt
V 85
180 V 180
Pw = = Pw = =
160 · 1000 · 3600 2000 23,6 160 · 1000 · 3600 1800 23,6
83 83
355
400
450
500
560
630
710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
450
500
560
630
710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,055 kgm2 BVRA 224 Number of blades: 8, moment of inertia: 0,075 kgm2 BVRA 250
= =
0
4000 4000
0,6
0,6
3
0,6
0,6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
Fan speed [rpm]*
3
0,7
0,7
Tip speed [m/s]
Please ask
0,7
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
1800 1800
0,6
0,6
]
[dB
[dB
W
Total pressurre difference 䉭pt [Pa] 씮*
L
ent
100 100
irem
560 560
irem
equ
98 98
450 450
r
400 400
put
95 95
in
in
355 355
er
er
pow
93 93
280 280
aft
aft
Sh
710
800
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,153 kgm2 BVRA 280 Number of blades: 8, moment of inertia: 0,25 kgm2 BVRA 315
= =
0
0
4000 4000
0,6
0,6
3
0,6
0,6
6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
Fan speed [rpm]*
3
0,7
0,7
Tip speed [m/s]
6
0,7
0,7
2500 2500
3
0,7
0,7
2240 2240
6
0,6
0,6
2000 2000
3
1800 1800
0,6
0,6
1600 4000 76,5 1600 3550 76,5
1400 1400
1250 108 3550 66,9 1250 3150 66,9
108
1120 1120
1000 3150 59,4 1000 2800 59,4
105 105
900 900
]
]
[dB
[dB
800 2800 52,7 800 2500 52,7
103 103
710 710
LW
LW
Total pressurre difference 䉭pt [Pa] 씮*
ent
100 100
560 560
irem
irem
500 2240 42,4 500 2000 42,4
equ
equ
98 98
450 450
ut r
ut r
400 2000 37,6 400 1800 37,6
95 95
inp
inp
355 355
er
er
315 1800 33 315 1600 33
pow
pow
93 93
280 280
aft
aft
250 1600 29,4 250 1400 29,4
90 90
Sh
Sh
224 Power requirement 224 Power requirement
200 at shaft: 1400 26,4 200 at shaft: 1250 26,4
V· · 䉭pt 88 V· · 䉭pt 88
180 Pw = = 180 Pw = =
160 · 1000 · 3600 1250 23,6 160 · 1000 · 3600 1120 23,6
85 85
900
1000
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
1120
1250
1400
1600
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,38 kgm2 BVRA 355 Number of blades: 8, moment of inertia: 0,618 kgm2 BVRA 400
= =
0
4000 4000
0,6
0,6
3
0,6
0,6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
3155 3155
Fan speed [rpm]*
Fan speed [rpm]*
3
3
0,7
0,7
2800 2800
6
6
0,7
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
1800 1800
0,6
0,6
[dB
[dB
103 103
560 560
irem
rem
equ
equ
100 100
450 450
ut r
ut r
355 355
er
er
95 95
280 280
p
aft
aft
1800
2000
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 0,933 kgm2 BVRA 450 Number of blades: 8, moment of inertia: 1,5 kgm2 BVRA 500
=
0
0
4000 4000 =
0,6
0,6
3
0,6
0,6
6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
Fan speed [rpm]*
3
0,7
0,7
Tip speed [m/s]
6
6
0,7
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
3
1800 1800
0,6
0,6
1600 2500 76,5 1600 2240 76,5
1400 1400
1250 2240 66,9 1250 2000 66,9
110 113
1120 1120
1000 2000 59,4 1000 1800 59,4
108 110
900 900
]
]
[dB
[dB
800 1800 52,7 800 1600 52,7
105 108
710 710
LW
LW
Total pressurre difference 䉭pt [Pa] 씮*
ent
103 105
560 560
irem
irem
500 1400 42,4 500 1250 42,4
equ
equ
100 103
450 450
ut r
ut r
400 1250 37,6 400 1120 37,6
98 100
inp
inp
355 355
er
er
315 1120 33 315 1000 33
pow
pow
95 98
280 280
aft
aft
250 1000 29,4 250 900 29,4
93 95
Sh
Sh
224 Power requirement 224 Power requirement
200 at shaft: 900 26,4 200 at shaft: 800 26,4
· · 䉭pt
V 90 · · 䉭pt 93
V
180 Pw = = 180 Pw = =
160 · 1000 · 3600 800 23,6 160 · 1000 · 3600 710 23,6
88 90
2240
2500
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
2800
3150
3550
4000
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 2,225 kgm2 BVRA 560 Number of blades: 8, moment of inertia: 3,5 kgm2 BVRA 630
= =
0
4000 4000
0,6
0,6
3
0,6
0,6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
3155 3155
Fan speed [rpm]*
Fan speed [rpm]*
3
3
0,7
0,7
2800 2800
6
6
0,7
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
1800 1800
0,6
0,6
[dB
[dB
L
L
105 105
560 560
irem
irem
103 103
450 450
r
r
100 100
in
in
355 355
er
er
98 98
280 280
aft
aft
4500
5000
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 7,0 kgm2 BVRA 710 Number of blades: 8, moment of inertia: 11,5 kgm2 BVRA 800
= =
0
0
4000 4000
0,6
0,6
3
0,6
0,6
6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
Fan speed [rpm]*
3
0,7
0,7
Tip speed [m/s]
6
6
0,7
0,7
2500 2500
3
0,7
0,7
2240 2240
6
0,6
0,6
2000 2000
3
1800 1800
0,6
0,6
1600 1600 76,5 1600 1400 76,5
1400 1400
1250 1400 66,9 1250 1250 66,9
115 115
1120 1120
1000 1250 59,4 1000 1120 59,4
113 113
900 900
]
]
[dB
[dB
800 1120 52,7 800 1000 52,7
110 110
710 710
LW
LW
Total pressurre difference 䉭pt [Pa] 씮*
ent
108 108
560 560
irem
irem
500 900 42,4 500 800 42,4
equ
equ
105 105
450 450
ut r
ut r
400 800 37,6 400 710 37,6
103 103
inp
inp
355 355
er
er
315 710 33 315 630 33
pow
pow
100 100
280 280
aft
aft
250 630 29,4 250 560 29,4
98 98
Sh
Sh
224 Power requirement 224 Power requirement
200 at shaft: 560 26,4 200 at shaft: 500 26,4
V· · 䉭pt 95 V· · 䉭pt 95
180 Pw = = 180 Pw = =
160 · 1000 · 3600 500 23,6 160 · 1000 · 3600 450 23,6
93 93
5600
6300
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
7100
8000
9000
10000
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
Volume flow Volume flow
· ·
V [m3/h]* V [m3/h]*
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 18 kgm2 BVRA 900 Number of blades: 8, moment of inertia: 32 kgm2 BVRA 1000
= =
0
4000 4000
0,6
0,6
3
0,6
0,6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
3155 3155
Fan speed [rpm]*
Fan speed [rpm]*
3
3
0,7
0,7
2800 2800
6
6
0,7
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
1800 1800
0,6
0,6
[dB
[dB
108 110
560 560
irem
irem
105 108
450 450
r
ut r
103 105
inp
in
355 355
er
er
100 103
280 280
aft
aft
11200
12500
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
Temperature: 20°C, density: 1,2 kg/m3 Temperature: 20°C, density: 1,2 kg/m3
Number of blades: 8, moment of inertia: 57,5 kgm2 BVRA 1120 Number of blades: 8, moment of inertia: 94 kgm2 BVRA 1250
=
0
0
4000 4000 =
0,6
0,6
3
0,6
0,6
6
6
3550 3550
0,6
0,6
0
0
0,7
0,7
Fan speed [rpm]*
3
0,7
0,7
Tip speed [m/s]
6
6
0,7
0,7
2500 2500
3
3
0,7
0,7
2240 2240
6
6
0,6
0,6
2000 2000
3
3
1800 1800
0,6
0,6
1600 1000 76,5 1600 900 76,5
1400 1400
1250 900 66,9 1250 800 66,9
118 118
1120 1120
1000 800 59,4 1000 710 59,4
115 115
900 900
]
]
[dB
[dB
800 710 52,7 800 630 52,7
113 113
710 710
LW
LW
Total pressurre difference 䉭pt [Pa] 씮*
ent
110 110
560 560
irem
irem
500 560 42,4 500 500 42,4
equ
equ
108 108
450 450
ut r
ut r
400 500 37,6 400 450 37,6
105 105
inp
inp
355 355
er
er
315 450 33 315 400 33
pow
pow
103 103
280 280
aft
aft
250 400 29,4 250 355 29,4
100 100
Sh
Sh
224 Power requirement 224 Power requirement
200 at shaft: 355 26,4 200 at shaft: 315 26,4
· · 䉭pt
V 98 · · 䉭pt 98
180 180 V
Pw = = Pw = =
160 · 1000 · 3600 315 23,6 160 · 1000 · 3600 280 23,6
95 95
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000
100000
112000
125000
140000
14000
16000
18000
20000
22400
25000
28000
31500
35500
40000
45000
50000
56000
63000
71000
80000
90000
100000
112000
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]* c1 = c2 [m/s]*
Dynamic Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]* pressure [Pa]*
4000 =
0,6
3
0,6
3550
0,6
0
0,7
3155
Fan speed [rpm]*
3
0,7
2800
6
0,7
2500
3
0,7
2240
6
0,6
2000
3
1800
0,6
630 500 47
ent
113
560
irem
110
450
r
108
in
355
er
315 355 33
pow
105
280
aft
Volume flow
· [m3/h]*
V
Flow velocity
4,0
4,5
5,0
5,6
6,3
7,1
8,0
9,0
10
11,2
12,5
14
16
18
20
22,4
25
28
31,5
c1 = c2 [m/s]*
Dynamic
10
12,5
16
20
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
pressure [Pa]*
* Data rounded to standard figures
– 185 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Type: BVRA
Carryover
– 186 –
Unit price Total
Item
Qty. Description
No.
2 2
Accessory equipment:
• Horizontally split casing
• Flexible connectors*
(temperature-resistant)
- inlet side
- outlet side
• Set of matching frames*
• Condensate drain
• Inspection hatch in the fan housing
• Set of spring-type antivibration mounts*
• Outlet for outdoor installation
• Weather protection for motor and V-belt drive
• Special coating for outdoor installation
• Galvanised fan casing
• Thermal insulation for fan casing
• Three-phase motor in accordance with IEC standard
style B3, protection class IP 55, insulation class B
single-speed unit
or with Dahlander pole-changing type
or pole-changing type with separate windings
Motor speed rpm
Motor output kW
Nominal motor current A
Voltage V
Frequency Hz
* Loosely supplied
Carryover
SMOKE EXHAUST PLUG FANS
CENTRIFUGAL TYPE
BV-ERV SERIES FOR 300°C – 120 MIN
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany OVERVIEW 187
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
sure measurements
- Three-phase motor, size ...
H
ca. Weight
Gewicht
Bau- Number of holes
Lochzahl
Size ØA H C i.d.
Ødi.L. ca.~ E F G b ~JJ
ca. K L Øk ohne Motor
(approx.)
größe z x Ød
BV-ERV
without
[kg]motor
250 306 250 290 256 617 258 179 180 403 240 420 286 6 7 25
280 348 250 290 288 639 260 202 180 426 240 420 322 8 10 30
Series 3 / DIN 24 154
315 386 285 350 322 710 310 220 180 478 285 500 356 8 10 38
355 425 320 350 361 733 310 249 180 533 285 500 395 8 10 45
400 468 360 435 404 860 410 270 180 594 385 675 438 12 10 65
450 517 400 435 453 895 410 308 180 650 385 675 487 12 10 80
500 571 450 435 507 940 415 345 180 736 385 705 541 12 10 95
560 643 530 480 569 998 430 389 180 852 405 730 605 16 12 115
630 712 570 480 638 1046 430 436 180 926 405 730 674 16 12 135
Series 2 / DIN 24 154
710 814 640 480 714 1186 510 496 180 1047 475 900 775 16 14 170
800 904 715 600 804 1240 510 550 180 1167 475 1000 861 24 14 250
900 1004 800 650 904 1478 680 618 180 1302 645 1150 958 24 14 340
1000 1105 900 650 1005 1545 680 685 180 1453 645 1115 1067 24 14 430
1120 1125 1000 780 1005 1679 740 734 205 1553 710 1350 1067 27 14 500
SMOKE EXHAUST FANS
SMOKE DETECTION SWITCHES FOR
MECHANICAL SMOKE EXTRACTION SYSTEMS
Am Weinberg 68 · D-36251 Bad Hersfeld/Germany 189
Phone: +49.6621.950-0 · Fax: +49.6621.950-100
Safety through certified to Building Rules List "B", Part 2, in The mechanical smoke extraction sy-
products conjunction with the relevant smoke stem is activated by pushbutton or
detectors. Compliance with the codes automatically by means of smoke
The purpose of a smoke and heat ex- is demonstrated via certification tests switches. A controller sends out con-
haust system is to protect human performed by independent testing in- trol signals to energize the powered
beings from the risks and hazard si- stitutes. smoke exhaust installation and to mo-
tuations typically encountered in a fi- ve the fire protection and smoke ex-
re. Smoke exhaust fans are tested ac- haust dampers into their safety positi-
cording to the European test standard on. An effective interaction between
This target can only be achieved via a EN 12101-3.
reliable mechanical smoke extraction the individual components ensures a
system. rapid detection and alarm response
Optimum component so that smoke can be extracted quick-
To provide optimum protection, the interaction ly from the fire zone.
individual components of a mechani-
cal smoke extraction installation must A powered smoke and heat exhaust
be optimally matched. system comprises at least the follo-
wing components:
Smoke exhaust fans and fire protec-
tion dampers therefore have to be ap- • Triggering device
proved by the German Institute of • Controller
Building Technology (DIBt) according • Smoke extraction system
Rauchschalter
Smoke-free layer
Pushbutton switch
Building services
management
system
Carryover
– 191 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Carryover
– 192 –
Unit price Total
Item
Qty. Description
No.
2 2
1.1 Controllers
Designed to control the mechanical smoke extraction
system and provide a visual indication of operating status
and alarms. Any transducing sensors connected to the
system remain activated throughout the smoke exhaust
cycle. Multiple controllers may be combined for the
purpose of managing a single powered smoke exhaust
system and actuating the associated smoke exhaust
dampers.
Approved by the German Institute of Building Technology
(DIBt) as an analyzing and triggering device for smoke
exhaust dampers and smoke exhaust fans.
- Smoke switch connection
- Connection of air supply dampers
- Connection of the smoke exhaust damper
- Connection for actuating the smoke exhaust fan
- Connection of a momentary-contact pushbutton switch
for manual triggering
- Connection of a momentary-contact pushbutton switch
for manual control of the smoke exhaust system
- Connection for audible alarm devices
- Connection for visual alarm devices
- Floating-contact alarm relay (changeover contact type,
30 V / 1A)
- Installation space for 2 additional alarm relays with two
changeover contacts each (250 VAC / 5 A)
Product covered by Building Supervision Authority
approval.
Mains voltage 230 VAC
Output voltage 24 VDC
Rated current max. 0,8 A
Protection class IP 20
DIBt-approval No.
Manufacturer
Type
1.2 Optical smoke switches
Designed as a triggering device for indoor (room)
monitoring, equipped with a smoke and heat sensor for
controlling mechanical smoke extraction systems. Units in
compliance with the DIBt code of practice, fitted in a
plastic housing with bayonet cap and featuring the
following:
Smoke detection by the stray light principle
Status indication via integrated LEDs, as follows:
LED green in operation
LED green/yellow (flashing slowly) slightly soiled
LED green/yellow (flashing rapidly) highly soiled
LED yellow measuring cell failure
LED red alarm
Carryover
– 193 –
Unit price Total
Lfd.
Qty. Description
Nr.
2 2
Information polled:
Type of smoke switch
Smoke switch manufacturing No. (PID)
Smoke switch ID No. within the system (allocated by the
system during first commissioning)
Operation
Slightly soiled
Highly soiled
Error / measuring cell failure
Unknown smoke switch within the system
Alarm
Temperature
RS 232 interface for PC or modem connection
PC log file documenting first commissioning data
PC log file documenting status polling
PC log file documenting prescribed maintenance
procedures including info on whether all connected
smoke switches were tested.
For apparent installation, colour: white
1.9 Modem
Manufacturer:
Type:
Qty:
Carryover
– 196 –
Unit price Total
Item
Qty. Description
No.
2 2
Carryover
SMOKE EXHAUST FANS
APPLICATION EXAMPLES/REFERENCES
Centrifugal smoke exhaust fan BV-REH 560 Axial smoke exhaust fan BVAXN 12/56/900 for 300°C - 120 Min. casing insulated
for 400°C - 120 Min. casing insulated (Alsenblöcke, Berlin)
(Alsenblöcke, Berlin)
Centrifugal smoke exhaust fan BVRA 710 Axial smoke exhaust fan BVAX 12/56/800
for 620°C - 90 Min. (Dorotheen-Blöcke, Berlin) for 300°C - 120 Min. with self-activating shutoff dampers (Dorotheen-Blöcke, Berlin)
Roof-mounting smoke exhaust fans BVD 630/30-6 Axial smoke exhaust fan BVAXN 8/56/1120
for 620°C - 120 Min. with stubs for admixture of ambient air for 600°C - 120 Min. with self-activating shutoff dampers and outlet duct
(Berlin State Archives) with wire guard (Oyten refrigerating facility)
SMOKE EXHAUST FANS
APPLICATION EXAMPLES / REFERENCES
Roof-mounting smoke exhaust fans BVD and axial smoke-exhaust fans BVAXN Roof-mounting smoke exhaust fans BVD
(Leipzig, Paunsdorf shopping mall) Check-in terminal, Franz-Josef Strauss
Airport, Munich
Roof-mounting smoke exhaust fans BVD 710 for 620°C–120 min. Wall-mounting smoke exhaust fans BVW-R
Cologne Arena Freight handling complex, Franz-Josef
Strauss Airport, Munich
Axial smoke exhaust fans for 400°C–120 min. with outlet diffusers Wall-mounting smoke exhaust fans BVW-A
(Düsseldorf Airport, Terminal C) Furniture store Unger, Wolfratshausen
TLT-Turbo GmbH
Am Weinberg 68
D-36251 Bad Hersfeld/Germany
Phone: + 49.6621.950-0
Fax: + 49.6621.950-100
E-mail: serie@tlt.de
Website: www.tlt.de
© 2005 - TLT-Turbo GmbH · 13th edition 02.04/1,25/G · Subject to errors and modifications.