GROUP 3 AUTOMATIC DECELERATION SYSTEM

Work equipment
pressure switch Travel oil pressure switch
Accel
Fuel injection actuator
pump
P M
Main control valve

Potentiometer signal

Motor drive signal

Auto decel switch signal Pressure switch signal


CPU controller
Accel dial signal

Accel dial

21075MS04

1. WHEN AUTO DECEL LAMP ON


If all the work equipment control levers including swing and travel levers are at neutral for at least 4
seconds, CPU controller drives the governor motor to reduce the engine speed to 1200rpm. As the
result of reducing the engine speed, fuel consumption and noise are effectively cut down during non-
operation of the control levers.
When the Auto decel lamp is turned off by pressing the switch or any control lever is operated, the
reduced engine speed rises upto the speed set before deceleration in a second.
Engine rpm

Accel dial set rpm

1200 rpm

Max Max
4sec 1.5sec 1.5sec

Lever Lever Time


neutral operation
21075MS05

2. WHEN AUTO DECEL LAMP OFF


The engine speed can be set as desired using the engine speed switch, and even if the control levers
are neutral, the engine speed is not reduced.
Note : Auto decel function can be activated when accel dial position is over 4.

5-6