WYE Strainers - Threaded Ends & Weld Ends WYE Strainers - Flanged Ends
Models: YS12 - YS52 - YS55 - YS56 - YS81 - YS82 - YS83 - YS84 - YS63 - YS65 Models: YS58 - YS59 - YS54 - YS61 - YS62 - YS64
4
2
2
1 1/
1 1/
2 1/
2 1/
1/4
3/8
1/2
3/4
Sizes (in):
10
12
14
16
18
20
24
Sizes (in):
8
10 10
7 7
6 6
5 5
4 4
3 3
2 2
00
0
0
0
0
110
160
260
400
570
950
160
220
330
490
610
800
110
110
160
Cv Cv Cv Cv
0.7
70
15
22
38
42
70
2
1 1
0.7 0.7
0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0.2 0.3 0.5 0.7 1 2 3 4 5 6 7 8 10 20 30 40 50 70 100 200 300 500 700 1000 20 30 40 50 70 100 200 300 500 700 1000 2000 3000 5000 10000 20000 50000
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis) Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
WYE Strainers - High Pressure - Class 900 &1500 WYE Strainers - High Pressure - Class 2500
Models: YS66 - YS67 - YS68 - YS69 Models: YS70 - YS71 - YS86
/2
/2
11
Sizes (in):
11
Sizes (in):
6
3
8
4
2
6
3
10 10
7 7
6 6
5 5
4 4
3 3
2 2
140
180
450
650
0
Cv Cv Cv Cv
42
60
30
42
10
16
37
60
1 1
0.7 0.7
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
10 20 30 40 50 60 70 100 200 300 400 500 700 1000 2000 3000 5000 5 6 7 8 10 20 30 40 50 60 70 100 200 300 400 500 700 1000 2000
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis) Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
• These curves are theoretical; actual results may vary depending on installation conditions and other variables. Use these values for reference only.
• The above pressure drop charts are based upon 1/8" perforated screens and baskets handling clean water at 60 °F during ideal inlet and outlet conditions. Therefore, they
should only be used for estimation purposes.
• For fluids other than water, multiply the pressure drop (Δ P) obtained from the charts by the specific gravity of the fluid in question.
• For mesh lined screens, multiply the pressure drop (Δ P) obtained from the charts by the corresponding correction factor shown in the Cv correction table.
Basket Strainers - Threaded Ends & Flanged Ends Basket Strainers - Flanged Ends
Models: BS25 - BS25F - BS35 - BS35F Models: BS55 - BS65 - BS85 - BS86
1 1 /4
3/8
2
/2
/2
1/2
2 1/
11
3/4
Sizes (in): Sizes (in):
21
10
12
14
16
18
20
24
2
8
3
1
8
10 10
7 7
6 6
5 5
4 4
3 3
2 2
00
00
00
00
0
0
00
135
290
490
780
160
325
520
800
100
135
165
225
0
Cv Cv Cv Cv
43
86
14
24
43
70
90
14
29
78
16
1 1
0.7 0.7
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
2 3 4 5 7 10 20 30 4050 70 100 200 300 500 1000 2000 5000 10000 20000 10 20 30 4050 70 100 200 300 500 1000 2000 5000 10000 20000 50000 100000
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis) Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
• These curves are theoretical; actual results may vary depending on installation conditions and other variables. Use these values for reference only.
• The above pressure drop charts are based upon 1/8" perforated screens and baskets handling clean water at 60 °F during ideal inlet and outlet conditions. Therefore, they
should only be used for estimation purposes.
• For fluids other than water, multiply the pressure drop (Δ P) obtained from the charts by the specific gravity of the fluid in question.
• For mesh lined screens, multiply the pressure drop (Δ P) obtained from the charts by the corresponding correction factor shown in the Cv correction table.