Sie sind auf Seite 1von 3

P.G.

information
Contact our sales office for delivery dates Point to Group
and prices as this is a special model. Specialized Product

Pulse Blowing Valve ON time adjustment needle

OFF time adjustment needle


Related product
∗ Please contact SMC for details.

AXTS040 - -X2
¡The peak pressure of
Features repeatedly colliding air
permits efficient
blowing.
 Air consumption: Port size: 1/4

Reduced by 50% or more ∗1 Port size: 1/2


AXTS040m-mm-X2
AXTS020-1P-X2

∗1 When ON time to OFF time is 1 to 1 (Duty ratio 0.5)

Pulse blow Continuous blow

Peak pressure
Reduced air
ON ON
(Valve open) (Valve open)

OFF OFF
Time Time
(Valve closed) (Valve closed)

 Control for pulse generation is not required. Pulse blow can be used by simply supplying air.

External pilot Internal pilot


Pulse blowing valve 2(B): Outlet side port Pulse blowing valve 4(A): Outlet side port

External pilot port 3(R2): Supply port 1(P): Supply port

External pilot
Supply air
3-port
solenoid valve

Supply Supply
air air
2-port
Pulse Blowing Valve solenoid valve Pulse Blowing Valve
AXTS040-3-X2 AXTS040-2-X2

 Long service life (200 million cycles or more)  ON/OFF time adjustable
individually
 Flow rate characteristics
Type of actuation C [dm3/(s·bar)] b Cv  Operating pressure range:
External pilot
Internal pilot
14
12
0.18
0.14
3.4
2.9
0.2 to 1.0 MPa

To ensure the safest possible operation of this product, please be sure to thoroughly read the
Caution “Safety Instructions” in our “Best Pneumatics” catalog before use.

4-14-1, SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL: http://www.smcworld.com SP178X-008E


©2018 SMC Corporation All Rights Reserved P: WS
Pulse Blowing Valve
P.G. information
Point to Group
Specialized Product
AXTS040m- mm-X2

How to Order

AXTS 040 3 -X2


Body size Direct manual override
040 1/2 Nil None
B Locking type
Thread type
Nil Rc
F G Type of actuation
N NPT 2 Internal pilot
T NPTF 3 External pilot

Specifications

Model AXTS040-2-X2 AXTS040-3-X2


Type of actuation Internal pilot External pilot
Valve construction Metal seal
Fluid Air
Operating pressure range 0.2 to 1.0 MPa 0 to 1.0 MPa
External pilot air pressure ­— 0.2 to 1.0 MPa
Frequency adjustment range 1 to 5 Hz 1 to 8 Hz
Proof pressure 1.5 MPa
Ambient and fluid temperatures –10 to 50°C
Lubrication Not required
C [dm3/(s·bar)] 12 14
Flow rate characteristics
b 0.14 0.18
(IN port  OUT port)
Cv 2.9 3.4

Dimensions [mm]

Internal pilot
Fig. 1
OUT port 4(A)
OUT port Plug Plus Minus

For OFF time


adjustment
For ON time
adjustment

PE port ∗ Turning the needle in the positive


IN port direction increases the frequency.
The frequency cannot be set to 5 Hz or higher.
Symbol 2 x ø6.5 mounting hole

ON time adjustment needle


With direct manual override
OFF time adjustment needle
Refer to Fig. 1.
OUT port 4(A)

Plug

Plug
Plug

PE port 3(R2)
∗ Silencer

IN port 1(P)
Pulse Blowing Valve
P.G. information
Point to Group
Specialized Product
AXTS040m-mm-X2

Dimensions [mm]

External pilot
Fig. 1

OUT port 2(B) Plus Minus


Plug

For OFF time


adjustment OUT port

For ON time
adjustment

∗ Turning the needle in the positive


direction increases the frequency.
IN port The frequency cannot be set to 8 Hz or higher.

Symbol 2 x ø6.5 mounting hole

With direct manual override ON time adjustment needle


OFF time adjustment needle
Refer to Fig. 1.

OUT port 2(B)


Plug

Plug
External pilot port 5(R1)

IN port 3(R2)

PE port 1(P)
∗ Silencer