ELCOS- Parma- Italy - CAM-120/10 - MAN - EN Valid for firmware revisions higher than or equal to 1.

31 1
2 Valid for firmware revisions higher than or equal to 1.31 ELCOS- Parma- Italy - CAM-120/10 - MAN - EN
ELCOS- Parma- Italy - CAM-120/10 - MAN - EN Valid for firmware revisions higher than or equal to 1.31 3
4 Valid for firmware revisions higher than or equal to 1.31 ELCOS- Parma- Italy - CAM-120/10 - MAN - EN
ELCOS- Parma- Italy - CAM-120/10 - MAN - EN Valid for firmware revisions higher than or equal to 1.31 5
6 Valid for firmware revisions higher than or equal to 1.31 ELCOS- Parma- Italy - CAM-120/10 - MAN - EN
N2
U2
V2
W2

ELCOS- Parma- Italy - CAM-120/10 - MAN - EN Valid for firmware revisions higher than or equal to 1.31 7
8 Valid for firmware revisions higher than or equal to 1.31 ELCOS- Parma- Italy - CAM-120/10 - MAN - EN
ELCOS- Parma- Italy - CAM-120/10 - MAN - EN Valid for firmware revisions higher than or equal to 1.31 9
NOTICES
Used only to check and command a genset unit..
It has been designed to be installed only inside on an electrical panel as a single unit and so that it
can be connected to other components (fuses, thermo-magnetic switch, etc.) which the installer will
have available to complete the plant.

Warning: Components carrying dangerous voltage levels


Only assigned and suitably trained personnel are allowed access to the control
unit. No maintenance operations are permitted unless the plant is disconnected
from the mains and the battery.
Not withstanding the above, only assigned and trained personnel can perform the
following operations with the plant on:
- make a visual inspection of the control unit, the connections and their markings;
- measure the voltage and/or current values;
- programming of the functions.
These interventions, however, must be performed using equipment which ensures
appropriate levels of electrical protection.

Warning:
Adhere closely to the following advice
- When making connections always follow the instructions and the W iring
Diagram on pages 6-7.
- Any interventions on the unit must be performed with the engine stationary
and terminal 50 of the starting motor disconnected.
- Check that the consumption of the connected equipment are compatible with the described
technical characteristics.
- Install in such a way that there is always adequate heat disposal.
- Always install under other equipment which produces or spreads heat.
- Handle and connect without mechanically stressing the electronic card.
- Make sure that no copper conductor cuttings or other waste material fall inside the control unit.
- Never disconnect the terminals of the battery with running engine.
- Never use a battery charger for the emergency start-up; the control panel could be damaged.
- In order to safeguard people and equipment, before connecting an external battery charger,
disconnect the electrical system terminals from the battery poles.
THIS CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING
CONDITIONS:
- Where the environmental temperature is outside the limits indicated in the manual.
- Where the air pressure and temperature variations are so rapid as to produce exceptional
condensation.
- Where there are high levels of pollution caused by dust, smoke, vapour, salts and corrosive or
radioactive particles.
- Where there are high levels or heat from radiation caused by the sun, ovens or the like.
- Where attacks from mould or small animals are possible.
- Where there is the risk of fire or explosions.
- Where the control panel can receive strong vibrations or knocks.
- Where the control panel is protected by barriers or casing with protection level less than IP40.
ELECTROMAGNETIC COMPATIBILITY
This control unit functions correctly only if inserted in plants which conform with the CE marking standards; it
meets the exemption requirements of the standard EN61326-1 but it cannot be excluded that malfunctions
could occur in extreme cases due to particular situations.
The installer has the task of checking that the disturbance levels are within the requirements of the
standards.
CONDUCTION AND MAINTENANCE
The following maintenance operations should be performed every week:
- check that the indicators function;
- check the batteries;
- check that the conductors are tight, check the condition of the terminals.

UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL


UNIT IS NOTSUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS
RESPONSIBLE FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE.

YOUR ELECTRICAL TECHNICIAN CAN ASK ANY QUESTIONS ABOUT


THIS CONTROL UNIT BY TELEPHONING OUR TECHNICIAN

10 Valid for firmware revisions higher than or equal to 1.31 ELCOS- Parma- Italy - CAM-120/10 - MAN - EN
TECHNICAL DATA
Battery power supply 12 Vdc and 24 Vdc
Supply voltage 8 y 32V
Self consumption with engine stopped (STAND BY) 4mA 12V 3mA 24V
Selfconsumption with engine stopped and modem connected 85mA at 12V 45mA at 24V
(STAND BY)
Selfconsumption with stopped engine and pressed emergency 190mA 12V 110mA 24V
button
Max consumption 265 mA 12V 150 mA 24V
Modem consumption 80 mA 12V 50 mA 24V
Suitable for generators with rated voltage of 220 y 450Vac r10%; frequency 50 y 60Hz
Rated insulation voltage:
• Terminal board of genset 500V
• Terminal board of battery 32V
Max load on the outputs 15 (starting) 3W, 17 (stopping) 7W, 19(key) 3W,
6 (glow plugs) 3W, 70 (general alarm) 3W.

Degree of rear protection IP00


Degree of front protection IP64
Temperature range -20 ÷ +50°C
Weight 430 g
Dimensions (LxHxP) mm 157x109x74
Hole mm 88x137
Hour-meter 5 digits
Instruments accuracy: oil pressare gauge, water thermometer, fuel 2%
level
Generator voltmeter Max 476V, accuracy ±1%
field of measurement 10 y 253 Vac (phase-neutral)
18 ÷ 476 Vac (phase-phase)
Rated current of the generator ammeter 5A
Generator ammeter Max 2400A, accuracy ±1%
field of measurement 0,02 (20ma) y 6A
Frequency meter accuracy ±0,1 Hz
frequency field 45 y 85Hz
Voltammeter and cosphimeter accuracy ± 2%
Wattmeter, varmeter and kilowatt-hour-meter accuracy ± 4%
Tachometer Max 4000 RPM accuracy ± 10 RPM
Serial communication parameters 9600 baud, 8 bit data, 1 bit stop; EVEN parity

ELCOS- Parma- Italy - CAM-120/10 - MAN - EN Valid for firmware revisions higher than or equal to 1.31 11
ORDERING DATA

Type CAM - 120 /10 code 00242285

ACCESSORIES SUPPLIED
KIT MU-CAM-120 code 40804432

12 Valid for firmware revisions higher than or equal to 1.31 ELCOS- Parma- Italy - CAM-120/10 - MAN - EN