STG Heating Private Limited is an Indian company that manufactures natural gas heating units. The document provides technical specifications for three of their MAX GAS models - the MAX GAS 40 P TL, MAX GAS 70 P TL, and MAX GAS 105 P TL. It lists details like their fuel type, thermal power range, inlet gas pressure limits, gas consumption rates, electrical requirements, and flame dimensions. Accessories for the units are also outlined along with their typical manufacturers.
STG Heating Private Limited is an Indian company that manufactures natural gas heating units. The document provides technical specifications for three of their MAX GAS models - the MAX GAS 40 P TL, MAX GAS 70 P TL, and MAX GAS 105 P TL. It lists details like their fuel type, thermal power range, inlet gas pressure limits, gas consumption rates, electrical requirements, and flame dimensions. Accessories for the units are also outlined along with their typical manufacturers.
STG Heating Private Limited is an Indian company that manufactures natural gas heating units. The document provides technical specifications for three of their MAX GAS models - the MAX GAS 40 P TL, MAX GAS 70 P TL, and MAX GAS 105 P TL. It lists details like their fuel type, thermal power range, inlet gas pressure limits, gas consumption rates, electrical requirements, and flame dimensions. Accessories for the units are also outlined along with their typical manufacturers.
Models Units MAX GAS 40 P TL MAX GAS 70 P TL MAX GAS 105 P TL
Fuel NG Natural Gas Natural Gas Thermal power max KW 48 70 108 Thermal Power min KW 17 34 49 Turn Down ratio 1:2.82 1:2 1:2.2 Maximum inlet pressure Mbar 300(N.G) 300 (N.G.) 300 (N.G.) 100 (LPG) 100 (LPG) 100 (LPG) Max. Consumption (NG) Nm3/Hr 4.82 7 10.8 Min. Consumption (NG) Nm3/Hr 1.71 3.4 5 Modulation Single Stage On-off Single Stage On-off Single Stage On-Off Voltage 50Hz V 230 V, Single phase 230 V, single phase 230 V, single phase Motor W 75 75 75 RPM N 2800 2800 2800 Ignition Transformer KV/mA 8/20 8/20 8/20 Flame Detector Landis Ionization Electrode Ionization Probe Ionization Probe
CALORIFIC VALUE → NG: 8570 Kcal/Nm3
FLAME DIMENSIONS
NATURAL GAS MAX GAS 40 P TL MAX GAS 70 P TL MAX GAS 105 P TL
Max Length 330 398 494 Max Diameter 195 221 256 Min Length 197 277 336 Min Diameter 138 174 198
ACCESSORIES MAKE
Sr.No. Accessories Make
1 Air Pressure Switch Krom Schroder/Dungs 2 Gas Pressure Switch Dungs 3 Motor Simel 4 Fan Wheel Ecoflam 5 Control Box Landis And Gyr/Satronics 6 Contactors And Relays Lovato 7 Flame Sensor Landis And Gyr 8 Burner Body And Blast Tube Ecoflam 9 Firing Head Ecoflam 10 Ignition Electrode Cast Srl 11 Diffuser Disc Ecoflam