Sie sind auf Seite 1von 5

Release 3.0.

0
Issued Oct 10, 2013

CSGW TOOL USER MANUAL

1. Introduction
1.1 CSGW Tool is a companion software used for generating configuration file of CSGW. CSGW
device is not required for running the software.
1.2 The software can be found at http://www.cs-controls.com/en/download.aspx?id=65, named CSGW
Tool. After downloading the software, extract it to a folder, e.g. C:\CSGWTool. Go to that folder,
run CSGW Tool v3.0.0.exe to launch the software.
1.3 The configuration file should be saved with .db as the extension name, which is required by
CSGW.
1.4 This Manual is supplementary to the CSGW User Manual. It does not cover topics related to
CSGW. For more information about CSGW, please refer to the CSGW User Manual. For example:
 How to upload Configuration file to CSGW.
 How to specify parameters for BACnet settings.
 How to create a mapping.

2. Operation Guide
CSGW can convert Modbus RTU or proprietary protocols to BACnet. CSGW Tool is usually used for
the purpose of Modbus RTU to BACnet.
To generate a configuration file using CSGW Tool, you can either
 Import from a CSV format points list file, or
 Manually add mappings via the GUI
It is recommended to use the former way, i.e., importing from points list file.

2.1 Import from a CSV format points list file


2.1.1 Before editing a points list file, some parameters need to be determined, such as device
addresses, communication parameters, BACnet settings, etc.
2.1.2 Find out the CSGW model (CSGW-1 ~ CSGW-4) on the main page of CSGW.

http://www.cs-controls.com 1/5
Release 3.0.0
Issue
ed Oct 10, 201
13

2.1
1.3 Open the
e template file Points Listt Template_R
R3.0.0.xlsx in
n the CSGW
W Tool folder,, switch to th
he
proper sheet according to the C
CSGW mode
el. Based on
n the examp
ple sheet, yo
ou can adjusst
device and communiication param
meters and add/remove//edit points a
according to
o your projecct.
Save the
e result to a different
d file when
w it is don
ne.

2.1
1.4 Save the
e file as CSV
V format.

http://www
ww.cs-controls..com 2/5
Release 3.0.0
Issue
ed Oct 10, 201
13

2.1
1.5 Run CSG
GW Tool v3.0
0.0.exe and import
i the CSV file.

1.6 Check the parameterrs of System Settings, BA


2.1 ACnet Setting
gs and Modb
bus RTU CO
OMx Settings.

2.1
1.7 Save the
e configuratio
on to a file, which
w name is
s composed of alphanum
meric only characters, e.g
g.:
test123.d
db.

http://www
ww.cs-controls..com 3/5
Release 3.0.0
Issue
ed Oct 10, 201
13

2.2 M
Manually ad
dd mappings
s via the GU
UI
2.2
2.1 Determin
ne parameterrs and CSGW
W model follo
owing 2.1.1~
~2.1.2.
2.2
2.2 Refer to 2.1.6 to set the parametters of Syste
em Settings//BACnet Setttings/Modbus RTU COM
Mx
Settings.
2.2
2.3 Select Modbus
M RTU
U COMx Setttings (e.g.: COM2),
C right-click to add
d a device and
a specify a
slave add
dress (e.g.: 1),
1 double cli ck Modbus RTU
R COM2 Settings
S to e xpand items
s below it.

2.2
2.4 Double click
c to expand Device 1 , there’re two items: Rea
ad Map and Write Map. Select a Ma
ap
item, righ
ht-click to add
d objects. By
y default a ne
ew added ob
bject name iss ‘Untitled’.

http://www
ww.cs-controls..com 4/5
Release 3.0.0
Issue
ed Oct 10, 201
13

2.2
2.5 Select th
he new added item, spec
cify paramete
ers as neces
ssary. Pleasee refer to the
e CSGW Use
er
Manual fo
or detailed in
nformation off these param
meters.

2.2
2.6 You can copy or dele
ete an item byy right-click iti (e.g.:01RM
M-T) to pop-u
up the contex
xt menu.

2.2
2.7 Refer to 2.1.7,
2 save the configura
ation file.

http://www
ww.cs-controls..com 5/5

Das könnte Ihnen auch gefallen