Sie sind auf Seite 1von 3

FRAME 2014B WINDING M1

MODELS LLB2014B / LLB2034B REF: F2004BWM1-3 APRIL 2010

WINDING DETAILS MECHANICAL DETAILS


Code M1 Insulation class H Standard protection IP23
Phase 1 Leads 4 Overspeed rpm 2250
Pole number 4 Pitch 2/3 Air flow 60Hz m3/s 0.32

EXCITATION DETAILS WAVEFORM


Excitation system SHUNT PMG No load or linear rated load
AVR model R251 R438 Total harmonic content THC <4%
Sustained short-circuit current - 300%:10s Telephone influence factor TIF (NEMA) <50
Steady state voltage regulation ±0.5% ±0.5% Telephone harmonic factor THF (IEC) <2%

VOLTAGE
Frequency / speed 50Hz / 1500rpm 60Hz / 1800rpm
Series V 220 230 240 220 230 240
Parallel V 110 115 120 110 115 120

1 2 3 4 6 7 8 9 10 11
RATING Power factor 1.0, Altitude <=1000m
Class H rise BR 125/40 kVA Not Available 40.0 40.0 40.0
kW - 40.0 40.0 40.0
Class H rise PR 150/40 kVA - 42.4 42.4 42.4
kW - 42.4 42.4 42.4
Class H rise PR 163/27 kVA - 44.0 44.0 44.0
kW - 44.0 44.0 44.0
Class F rise BR 105/40 kVA - 36.4 36.4 36.4
kW - 36.4 36.4 36.4

EFFICIENCIES Power factor 1.0


110% Class H BR % - 83.6 84.5 85.3
100% Class H BR % - 84.5 85.3 86.1
75% Class H BR % - 86.5 87.1 87.7
50% Class H BR % - 87.5 87.9 88.3
25% Class H BR % - 86.0 86.1 86.1

CHARACTERISTIC PARAMETERS Reactance base class H BR rating


Kc Short-circuit ratio - 0.37 0.42 0.48
Xd D-Axis synchronous reactance (unsaturated) pu - 2.80 2.56 2.35
X'd D-Axis transient reactance (saturated) pu - 0.27 0.24 0.23
X''d D-Axis sub-transient reactance (saturated) pu - 0.132 0.121 0.111
Xq Q-Axis synchronous reactance (unsaturated) pu - 1.68 1.53 1.41
X''q Q-Axis sub-transient reactance (saturated) pu - 0.166 0.152 0.140
X2 Negative-sequence reactance (saturated) pu - - - -
X0 Zero-sequence reactance (independent) pu - - - -
T'd D-Axis transient time constant ms - 80
T''d D-Axis sub-transient time constant ms - 7
T'do D-Axis open-circuit time constant ms - 1131
Ta Armature time constant ms - 12
Tr Voltage recovery time ms - < 500

EXCITATION VOLTAGE AND CURRENT

No load excitation voltage V - 7.4 8.1 8.8


No load excitation current A - 0.53 0.58 0.63
Class H BR excitation voltage V - 22.4 22.0 21.8
Class H BR excitation current A - 1.61 1.58 1.57

WINDING RESISTANCE At 20 o C
Stator (series) Ω 0.058 Exciter field Ω 13.9
Main field Ω 1.35

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 2014B WINDING M1

MODELS LLB2014B / LLB2034B REF: F2004BWM1-3 APRIL 2010

LOCKED ROTOR MOTOR STARTING CURVES Power factor 0.9

60 Hz SHUNT / PMG

220V

230V

240V
35

30

25
voltage dip %

20

15

10

0
0 10 20 30 40 50 60 70 80
kVA

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 2014B WINDING M1

MODELS LLB2014B / LLB2034B REF: F2004BWM1-3 APRIL 2010

SHORT-CIRCUIT DECREMENT CURVES No-load excitation at rated speed

240V 60Hz Series

10000

asymmetrical
RMS current (A)

1000
symmetrical
PMG

SHUNT
100
1 10 100 1000 10000
time (ms)

Multiplication Factors

50Hz Voltages 220 230 240

Multiplication Factor Not Available

60Hz Voltages 220 230 240

Multiplication Factor 0.92 0.96 1.00

Apply factor up to 2xT'd, remainder of curve unchanged

Winding Connection Series Parallel

Multiplication Factor 1.00 2.00

Apply factor to the complete curve

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.