QuickChart EIT 2 – Bell, intercom and lighting systems
Intercom unit with
w door opener
L1
N
PE
Fl t
Flat
Door Flat
Door
www.lucass-nuelle.de
QuickChart EIT 2 – Bell, intercom and lighting systems
Pulse relays
Safety instructions
Al
Always observe
b any regulations
l ti and
d
standards that apply in your locale when
using electrical equipment.
Example connection
Switch setting Priority
Off Permanently off
local
on/off Res-
ponse
witches still work. The most central
No priority. Even if central control inputs are permanently switched on, local sw
1/5*
/
i t ti i
instruction is executed (by default):
t d (b d f lt)
2/6* Priority for switching centrally. Local switches are ineffective but a central off rrequest has priority over an on request.
Central off
Centtral on
3/7* Priority for switching centrally. Local switches are ineffective but a central on request has priority over an off request.
Priority for local switches that are held on. Centralised instructions are not exeecuted until the switch is released. Glow
4/8*
lamp current cannot be tolerated in this setting.
lamp current cannot be tolerated in this setting
ON
OFF
On Permanently on
G/2_v1.0
www.lucass-nuelle.de
SO6205-4G
QuickChart EIT 2 – Bell, intercom and lighting systems
Stairway
y lighting
L1
N
PE