Column Strip
Support Section SIDL 11
Total load 21 KN/m2 LL 4
Shorter span(L2) 7.37 m DL 5.625
Longer span(L1) 7.50 m TOTAL LOAD 20.625
Mo (kNm) 1089.097
Mcss (0.75x0.65xMo)x2.75x0.475/(2.75x0.475+1.0x0.225) 452.92
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
Column Strip
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.03 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.10 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.54 N/MM²
V Vu/bo*d
0.614 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 8 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.38 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.33 N/MM²
V Vu/bo*d
0.614 N/mm²
Hence safe
Middle Strip
Support Section
Mo (kNm) 1089.097
Mmss (0.25x0.65xMo), 0.65Mo-D4 254.9932
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.06 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
3.50 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-6.22 N/MM²
Moment of resistance only for PT Tendons
fpb*Aps*(d-0.45xu) 362 KNm
& total moment 382.48986671 KNm
So,the remaining moment only for which reinforcement has to be provided 21 KNm
Provided Reinforcement
Middle Strip
Mid Span Section
Mo (kNm) 1089.097
Mmsm (0.40x0.35xMo),0.35Mo-D89 213.4631
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 12 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.06 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.71 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
2.00 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.04 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.45 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.25 N/MM²
V Vu/bo*d
0.614 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 10 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.03 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
2.23 N/MM²
Middle Strip
Support Section
Mo (kNm) 1069.364
Mmss (0.25x0.65xMo), 0.65Mo-D4 250.373
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.30 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-5.82 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1069.364
Mmsm (0.40x0.35xMo),0.35Mo-D89 209.5953
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.24 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.72 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.04 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.94 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.75 N/MM²
V Vu/bo*d
0.673 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 10 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.85 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.05 N/MM²
Middle Strip
Support Section
Mo (kNm) 1193.063
Mmss (0.25x0.65xMo), 0.65Mo-D4 279.3349
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.69 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-5.83 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1193.063
Mmsm (0.40x0.35xMo),0.35Mo-D89 233.8403
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.32 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
1.18 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.04 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.31 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-4.12 N/MM²
V Vu/bo*d
0.673 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 12 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-7.25 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
2.68 N/MM²
Middle Strip
Support Section
Mo (kNm) 1285.326
Mmss (0.25x0.65xMo), 0.65Mo-D4 300.9368
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
3.17 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-6.31 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1285.326
Mmsm (0.40x0.35xMo),0.35Mo-D89 251.9239
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.72 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
1.58 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.05 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.01 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-4.17 N/MM²
V Vu/bo*d
0.744 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 12 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-7.69 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.12 N/MM²
Middle Strip
Support Section
Mo (kNm) 1351.655
Mmss (0.25x0.65xMo), 0.65Mo-D4 316.4667
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.35 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-5.86 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1351.655
Mmsm (0.40x0.35xMo),0.35Mo-D89 264.9245
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 20 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.27 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.77 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.06 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.61 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-4.50 N/MM²
V Vu/bo*d
0.744 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.13 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-8.49 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
2.40 N/MM²
Middle Strip
Support Section
Mo (kNm) 1536.452
Mmss (0.25x0.65xMo), 0.65Mo-D4 359.7336
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.12 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
3.05 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-8.34 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1536.452
Mmsm (0.40x0.35xMo),0.35Mo-D89 301.1446
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 24 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.12 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.03 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.74 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.04 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.94 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.73 N/MM²
V Vu/bo*d
0.675 N/mm²
Hence safe
Column Strip
Mid Span Section
Mo (kNm) 1197.492
Mcsm (0.60x0.35xMo)x2.75x0.225/(2.75x0.225+1.0x0.225) 184.4138
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 10 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.82 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.05 N/MM²
Middle Strip
Support Section
Mo (kNm) 1197.492
Mmss (0.25x0.65xMo), 0.65Mo-D4 280.372
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.09 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.84 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-5.76 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1197.492
Mmsm (0.40x0.35xMo),0.35Mo-D89 234.7085
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 20 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.09 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.12 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.19 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.06 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
0.64 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.53 N/MM²
V Vu/bo*d
0.675 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.13 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.89 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.80 N/MM²
Middle Strip
Support Section
Mo (kNm) 1294.888
Mmss (0.25x0.65xMo), 0.65Mo-D4 303.1756
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.63 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-7.04 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1294.888
Mmsm (0.40x0.35xMo),0.35Mo-D89 253.7981
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 20 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-5.10 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.69 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.03 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
0.34 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-1.78 N/MM²
V Vu/bo*d
0.468 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 8 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-3.47 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.43 N/MM²
Middle Strip
Support Section
Mo (kNm) 651.5827
Mmss (0.25x0.65xMo), 0.65Mo-D4 152.5568
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.05 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.44 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-3.82 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 651.5827
Mmsm (0.40x0.35xMo),0.35Mo-D89 127.7102
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 10 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.05 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-2.77 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.39 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.02 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.48 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-2.56 N/MM²
V Vu/bo*d
0.468 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 6 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.05 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.62 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
2.34 N/MM²
Middle Strip
Support Section
Mo (kNm) 792.6303
Mmss (0.25x0.65xMo), 0.65Mo-D4 185.5806
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.09 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.52 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-6.52 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 792.6303
Mmsm (0.40x0.35xMo),0.35Mo-D89 155.3555
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 12 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.09 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.74 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.74 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.04 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.96 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.76 N/MM²
V Vu/bo*d
0.675 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 10 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.08 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-6.88 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.07 N/MM²
Middle Strip
Support Section
Mo (kNm) 1196.754
Mmss (0.25x0.65xMo), 0.65Mo-D4 280.1992
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.71 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-5.85 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1196.754
Mmsm (0.40x0.35xMo),0.35Mo-D89 234.5638
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-4.34 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
1.19 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.05 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.78 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.95 N/MM²
V Vu/bo*d
0.675 N/mm²
Hence safe
Column Strip
Mid Span Section
Mo (kNm) 1294.888
Mcsm (0.60x0.35xMo)x2.75x0.225/(2.75x0.225+1.0x0.225) 199.4128
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 12 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-7.32 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
2.75 N/MM²
Middle Strip
Support Section
Mo (kNm) 1294.888
Mmss (0.25x0.65xMo), 0.65Mo-D4 303.1756
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.63 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-7.04 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1294.888
Mmsm (0.40x0.35xMo),0.35Mo-D89 253.7981
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 20 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.10 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-5.10 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.69 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.02 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.06 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-3.14 N/MM²
V Vu/bo*d
0.673 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 6 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.05 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-5.59 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.30 N/MM²
Middle Strip
Support Section
Mo (kNm) 937.9877
Mmss (0.25x0.65xMo), 0.65Mo-D4 219.6135
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
1.36 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-4.51 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 937.9877
Mmsm (0.40x0.35xMo),0.35Mo-D89 183.8456
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.07 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-3.21 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.07 N/MM²
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.06 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.03 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 392.5 MM²
-4.91 N/MM²
V Vu/bo*d
0.673 N/mm²
Hence safe
1842.5 3685
2750 4620
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 16 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.13 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-9.18 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
3.09 N/MM²
Middle Strip
Support Section
Mo (kNm) 1640.284
Mmss (0.25x0.65xMo), 0.65Mo-D4 384.044
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.11 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
2.82 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 1373.75 MM²
-7.93 N/MM²
Middle Strip
Mid Span Section
Mo (kNm) 1640.284
Mmsm (0.40x0.35xMo),0.35Mo-D89 321.4957
DESIGN CALCULATIONS FOR THE POSITIVE MOMENT OF THE GRID LOCATION -3
SECTIONAL PROPERTIES
mid Depth -d 54 MM
Number of Strands 26 Nos. Number of Strands 10 Nos.
(-P/A-Pe/Z+M/Z)
fpu*Aps/fcu*b*d 0.11 fpe/fpu 0.6
On the basis of these two ratios we can determine fpb/0.95fpu from table7.3
fpb/0.95fpu 1 X/d 0.14
-5.72 N/MM²
fpb 1767 N/MM²
(-P/A+Pe/Z-M/Z)
Aps 981.25 MM²
0.61 N/MM²