IMP NOTE : - PREFERABLEY TESTED MECHANICAL COUPLER SHALL BE USED FOR TO JOIN ALL BARS.

IMP NOTE : - IN THE LAPPING ZONE PROVIDE TACK / DOT


Beam Size at WELDING TO LAP BARS AT 200MM C/C Beam Size at
End is 800x1250 tapering End is 800x1250 tapering 800
to800x900 towards to800x900 towards
center to be joined 50% TOP BARS 50% TOP BARS center to be joined

200
LAPPED AT 7850mm LAPPED AT 7850mm
FROM SUPPORT FROM SUPPORT

1250
EXTRA TOP BAR ALTERNATIVELY EXTRA TOP BAR
ALTERNATIVELY
09 - 32Dia 09 - 32Dia
6250mm Long 6250mm Long
FULL TOP BAR PIN BAR
EXTRA TOP BARS
8650 09 - 32Dia 8650 01 - 25Dia
800mm Long End bent to all top,bottom &
1600 Size of Beam at center
1600
PIN BAR lapzone extra top bars is compulsory
lapzone SECTION
01 - 25Dia 7850 800x900mm 7850 at all discontinuous ends.
800mm Long 9310 NEAR END FOR "FB26"
Rings of Column
at every Beam-column
Ld=1000

junction are 800

900
compulsory
1250

1250

900

200
SIDE FACE R/F
10910 ON EACH FACE
1000mm Bend 04 - 12Dia
1000 6250 6250 1000
to all Top ,
Bottom 1600 1600
& Extra top 7050 7050 SECTION CURTAIL BARS
bars 23410 NEAR MID SPAN FOR "FB26"
Column lapzone lapzone
Column
50% BOTTOM BARS CURTAIL BAR 50% BOTTOM BARS
FULL BOTTOM BAR LAPPED AT 6250mm 04 - 32Dia LAPPED AT 6250mm
09 - 32Dia FROM SUPPORT 17000mm Long FROM SUPPORT
ALTERNATIVELY ALTERNATIVELY

6-LEGGED RING / STIRRUP


SECTION-XX (TYP. SECTION THROUGH BEAM FB26)