HCT
Three phase / Three phase

10~200 kVA
SelfProtec offers a new generation of HCT inver-
ters : ON-LINE double conversion Three Phase in
– Three Phase out UPS’s (Uninterruptible Power
• Double conversion on line technology Supply) with transformer that now have an output
• Output power factor : 0.9 power factor of 0.9. Specially conceived for cri-
• Three phase in, three phase out tical applications protection suche as data cen-
• Pure sinewave output ters, industrial applications etc., they offer excel-
• Static bypass lent efficiency and great reliability.
• Manual maintenance bypass
• Double CPU control The ONLINE technology is the only one ensuring
• LCD with control panel power supply with excellent match to the load,
• Self diagnosis without frequency or voltage drifts, providing a
• Low noise true sine-wave signal, independently from mains
• High efficiency voltage and free from output Interruptions. In the
• 6 pulses harmonic filter event of mains failure, energy is drawn from the
• Wide input voltage range UPS batteries, guarantying an uninterrupted out-
• Included Software put voltage.

AVAILABLE OPTIONS Each HCT UPS is equipped with a static bypass


• SNMP Communication to manage overloads and a manual by-pass for
• E.P.O. (Emergency Stop) maintenance and emergencies.
• Backup Time extension
• Parrallel / redundant architecture The user friendly operation panel displays the UPS
• Remote control panel status and alarms and allows easy UPS manage-
• 12 pulses harmonic filter ment.

selfprotec.com
HCT Three:Three

HCT 10K 20K 30K 40K 60K 80K 100K 120K 160K 200K
Capacity 10 kVA 20 kVA 30 kVA 40 kVA 60 kVA 80 kVA 100 kVA 120 kVA 160 kVA 200 kVA
Power 9 kW 16 kW 27 kW 36 kW 54 kW 72 kW 90 kW 108 kW 144 kW 180 kW
Power Factor Input : PFC > 0.8 (standard) / 1 (with filtre), Output : Cos (φ) = 0.9
Input
Phase 3 phases : 3P + N +T
Nominal voltage 380 / 400 / 415 V
Voltage range ±25%
Nominal frequency 50 / 60 Hz
Frequency range ±5 Hz
Rectifier 3 phases, 6 pulses
Output
Phase 3 phases : 3P + N +T
Wave Form Pure sine-wave
Crest Factor 3:1
Nominal voltage 380/400/415V (option)
Phases voltage 200 - 244VAC (adjustable)
Transient response ±5%,10ms
Frequency 50/60 Hz
Frequency range + 0.05%
Range of phase lock With synchronization: 0.05% / without synchronization: 2% (adjustable to 1%)
Harmonic distortion THD 3% (linear load)
Short-circuit current for 0.1s (@ 200% current)
Overload 110% : 60 min, /125% : 10 min /150% : 1 min
Batteries
Type Sealed, lead-acid, without maintenance
Total voltage 480 Vdc
Bypass
Type automatic + manual
Input phases 3 phase : 3P + N +T
Input voltage range [10% ~ -40%] ~[+10 ~ +20%] (adjustable)
Input frequency range ±1% ~ ±5% (adjustable)
Transfer time Overload : 0 ms / Fault: 1 ms (UPS / by-pass)
System
Remote Signal Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA
Control Signal EPO & by-pass
Interface RS232 ( SNMP, modem : optional)
Temperature 0-40 °C
Relative Humidity < 95% (non condensing)
Elevation <1000m at nominal output power (-1% with each 100m above it), max 4000m
Noise @ 1 m < 65dB < 68dB < 72dB
Efficiency 88% 89% 90% 90% 91% 91% 91.5% 91.5% 92% 92%
Protection IP20
Norms EN50091-1-EMC EN50091-2liv.A
Isolation transformer
Options Harmonic wave suppression filter
Parallel architecture (up to six units)
Weight w/o batteries 223 260 336 351 490 575 755 900 1300 1350
Dim. (DxWxH) mm 555 × 720 × 1220 800 × 745 × 1400 1070 × 745 × 1400 1420 × 750 × 1805