Sie sind auf Seite 1von 42

2 .

Earth Work
Code Description Unit Rate

2.3.1A Supplying and filling with good earth cum 159.17


(excluding rock) in layers not exceeding 20cm
in depth, breaking clods, watering, rolling each
layer with 1/2 tonne roller, or wooden or steel
rammers, and rolling every 3rd and top-most
layer with power roller of minimum 8 tonnes
capacity including all leads and lift (payment
will be made based on level measurement).

2.26B Supplying and filling with good earth cum 155.82


(excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm
in deapth consolidating each deposited layers
by ramming and watering etc. complete
including all lead and lift.

2.28 Supplying and filling in plinth with river sand cum 344.69
under floors including, watering, ramming
consolidating and dressing complete.
4 . Concrete Work
Code Description Unit Rate

4.5.1 Providing and laying in position cement cum 3237.36


concrete of specified grade excluding the cost
of centring & shuttering- All work upto plinth
level - 1:1:2 (1 cement : 1 sand : 2 graded
stone aggregate 20mm nominal size).

4.5.2 providing and laying in position cement cum 2455.38


concrete of specified grade excluding the cost
of centring and shuttering - All work upto plinth
level 1:1.5:3 (1 cement : 1.5 sand : 3 graded
stone aggregate 20mm nominal size).

4.5.3 Providing and laying in position cement cum 2205.51


concrete of specified grade excluding the cost
of centring and shuttering - All work upto plinth
level 1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size).

4.5.4 Providing and laying in position cement cum 2150.96


concrete of specified grade excluding the cost
of centring and shuttering -All work upto plinth
level 1:2:4 (1 cement: 2 coarse sand: 4 graded
stone aggregate 40mm nominal size)

4.5.5 Providing and laying in position cement cum 1876.22


concrete of specified grade excluding the cost
of centring and shuttering - All work upto plinth
level 1:3.6 (1 cement : 3 sand : 6 graded stone
aggregate 20mm nominal size).

4.5.6 Providing and laying in position cement cum 1826.44


concrete of specified grade excluding the cost
of centering and shuttering - All work upto
plinth level 1:3:6 (1 cement : 3 sand : 6 graded
stone aggregate 40mm nominal size).

4.5.8 Providing and laying in position cement cum 1643.13


concrete of specified grade excluding the cost
of centring and shuttering - All work upto plinth
level 1:4:8 (1 cement : 4 sand : 8 graded stone
aggregate 40mm nominal size).

4.5.10 Providing and laying in position cement cum 1496.47


concrete of specified grade excluding the cost
of centring and shuttering - All work upto plinth
level 1:5:10 (1 cement : 5 sand : 10 graded
stone aggregate 40mm nominal size).
4.5.12 Providing and laying in position cement cum 1225.46
concrete of specified grade excluding the cost
of centring and shuttering - All work upto plinth
level 1:5:10 (1 cement : 5 sand : 10 graded
brick aggregate 40mm nominal size).

4.6.1 Providing and laying cement concrete in cum 3436.81


retaining walls, return walls, walls (any
thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts,
buttresses, string or lacing courses, parapets,
coping, bed blocks, anchor blocks, plain window
sills, fillets etc. upto floor five level, excluding
the cost of centring, shuttering and finishing -
1:1:2 (1 cement : 1 sand : 2 graded stone
aggregate 20mm nominal size)

4.6.2 Providing and laying cement concrete in cum 2654.84


retaining walls, return walls, walls (any
thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts,
buttresses, string or lacing courses, parapets,
coping, bed blocks, anchor blocks, plain window
sills, fillets etc. upto floor five level, excluding
the cost of centring, shuttering and finishing -
1:1.5:3 (1 cement : 1.5 sand : 3 graded stone
aggregate 20mm nominal size)

4.6.3 Providing and laying cement concrete in cum 2404.97


retaining walls, return walls, walls (any
thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts,
buttresses, string or lacing courses, parapets,
coping, bed blocks, anchor blocks, plain window
sills, fillets etc. upto floor five level, excluding
the cost of centring, shuttering and finishing -
1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size)

4.6.4 Providing and laying cement concrete in cum 2350.43


retaining walls, return walls, walls (any
thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts,
buttresses, string or lacing courses, parapets
coping, bed blocks, anchor blocks, plain window
sills, fillets etc. upto floor five level, excluding
the cost of centring, shuttering and finishing -
1:2:4 (1 cement:2 coarse sand:4 graded stone
aggregate 20mm nominal size)

4.6.5 Providing and laying cement concrete in cum 2075.67


retaining walls, return walls, walls (any
thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts,
buttresses, string or lacing courses, parapets,
coping, bed blocks, anchor blocks, plain window
sill, fillets etc. upto floor five level, excluding
the cost of centring, shuttering and finishing -
1:3:6 (1 cement : 3 sand : 6 graded stone
aggregate 20mm nominal size)

4.6.6 Providing and laying cement concrete in cum 2025.90


retaining walls, return walls, walls (any
thickness) including attached pilasters, columns,
piers, abutments, pillars, posts, struts,
buttresses, string or lacing courses, parapets,
coping, bed blocks, anchor blocks, plain window
sill, fillets etc. upto floor five level, excluding
the cost of centring, shuttering and finishing -
1:3:6 (1 cement : 3 sand : 6 graded stone
aggregate 40mm nominal size)

4.10.1 Providing and laying cement concrete in kerbs, cum 2205.51


steps and the like at or near ground level
excluding the cost of centring, shuttering and
finishing - 1:2:4 (1 cement : 2 sand : 4 graded
stone aggregate 20mm nominal size).

4.10.2 Providing and laying cement concrete in kerbs, cum 1876.21


steps and the like at or near ground level
excluding the cost of centring, shuttering and
finishing - 1:3:6 (1 cement : 3 sand : 6 graded
stone aggregate 20mm nominal size).

4.16.1 Providing and fixing upto floor five level precast cum 3257.44
cement concrete string or lacing courses,
copings, bed plate, anchor block, plain window
sill, shelves, louvers, steps, stair cases etc.
including hoisting and setting in position with
cement mortar 1:3 (1 cement : 3 sand), cost of
centring, shuttering and finishing smooth with
6mm thick cement plaster 1:3 (1 cement : 3
sand) on exposed surface complete - 1:2:4 (1
cement : 2 sand : 4 graded stone aggregate
20mm nominal size)

4.16.2 Providing and fixing upto floor five level precast cum 2928.16
cement concrete string or lacing courses,
copings, bed plate, anchor block, plain window
sill, shelves, louvers, steps, stair cases etc.
including hoisting and setting in position with
cement mortar 1:3 (1 cement : 3 sand), cost of
centring, shuttering and finishing smooth with
6mm thick cement plaster 1:3 (1 cement : 3
sand) on exposed surface complete - 1:3:6 (1
cement : 3 sand : 6 graded stone aggregate
20mm nominal size).
4.17.1 Providing and fixing at or near ground level cum 2793.00
precast cement concrete in kerbs, edgings etc.
as per approved pattern and setting in position
with cement mortar 1:3 (1 cement : 3 sand)
including the cost of required centring,
shuttering and finishing smooth with 6mm thick
cement plaster 1:3 (1 cement : 3 sand) on
exposed surfaces complete - 1:2:4 (1 cement : 2
sand : 4 graded stone aggregate 20mm
nominal size)

4.24 Providing and laying damp-proof Course 40mm sqm 93.09


thick with cement concrete 1:2:4 (1 cement : 2
sand : 4 graded stone aggregate 12.5mm
nominal size)

4.25 Providing and laying damp-proof Course 50mm sqm 123.77


thick with cement concrete 1:2:4 (1 cement : 2
sand : 4 graded stone aggregate 20mm
nominal size)
5 . Reinforced Concrete Work
Code Description Unit Rate

5.1.1 Providing and laying in position specified grade cum 3305.24


of reinforced cement concrete excluding the
cost of centring, shuttering, finishing and
reinforcement - All work upto plinth level - 1:1:2
(1 cement :1 sand : 2 graded stone aggregate
20mm nominal size)

5.1.2 Providing and laying in position specified grade cum 2527.98


of reinforced cement concrete excluding the
cost of centring, shuttering,finishing and
reinforcement - All work upto plinth level -
1:1.5:3 (1 cement :1.5 sand : 3 graded stone
aggregate 20mm nominal size)

5.1.3 Providing and laying in position specified grade cum 2273.39


of reinforced cement concrete excluding the
cost of centring, shuttering, finishing and
reinforcement - All work upto plinth level - 1:2:4
(1 cement : 2 sand : 4 graded stone aggregate
20mm nominal size)

5.2.1 Reinforced cement concrete work in walls (any cum 3522.67


thickness) including attached pilasters,
buttresses, plinth and string courses, fillets,
columns, pillars, piers, abutmeents, posts and
struts, etc. upto floor five level excluding cost of
centring, shuttering, finishing and reinforcement
- 1:1:2 (1 cement : 1 sand : 2 graded stone
aggregate 20mm nominal size).

5.2.2 Reinforced cement concrete work in walls (any cum 2745.42


thickness) including attached pilasters,
buttresses, plinth and string courses, fillets,
columns, pillars, piers, abutmeents, posts and
struts, etc. upto floor five level excluding cost of
centring, shuttering, finishing and reinforcement
- 1:1.5:3 (1 cement : 1.5 sand : 3 graded
stone aggregate 20mm nominal size).

5.2.3 Reinforced cement concrete work in walls (any cum 2490.83


thickness) including attached pilasters,
buttresses, plinth and string courses, fillets,
columns, pillars, piers, abutmeents, posts and
struts, etc. upto floor five level excluding cost of
centring, shuttering, finishing and reinforcement
- 1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size).
5.3 Reinforced cement concrete work in beams, cum 2476.54
suspended floors, roof having slope upto 15
degree, landings, balconies, shelves, chajjas,
lintels, bands,plain window sills, staircases and
spiral cases upto floor five level excluding cost
of centring, shuttering, finishing and
reinforcement with 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm
nominal size).
5.3.1 Reinforced cement concrete work in beams, cum 2731.12
suspended floors, roofs having slope upto 15
degree, landings, balconies, shelves, chajjas,
lintels, bands, plain window sills, staircases and
spiral staircases upto floor five level excluding
the cost of centring, shuttering, finishing and
reinforcement with 1:1.5:3 (1 cement : 1.5
coarse sand : 3 graded stone aggregate 20mm
nominal size).

5.9 Providing and laying upto floor five level cum 2025.57
reinforced cement concrete in kerbs, steps and
the like excluding the cost of centring,
shuttering, finishing and reinforcement with
1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size)

5.9.1 Providing and laying upto floor five level cum 2280.16
reinforced cement concrete in kerbs, steps and
the like excluding the cost of centring,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 sand : 3 graded stone
aggregate 20mm nominal size)

5.10 Reinforced cement concrete work in arches, cum 2399.45


archribs, domes, vaults, shells, folded plate and
roofs having slope more than 15 degree upto
floor five level excluding cost of centring,
shuttering, finishing and reinforcement with
1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size).

5.10.1 Reinforced cement concrete work in arches, cum 2654.03


archribs, domes, vaults, shells, folded plate and
roofs having slope more than 15 degree upto
floor five level excluding the cost of centring,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 sand : 3 graded stone
aggregate 20mm nominal size).

5.11 Reinforced cement concrete work in chimneys, cum 2515.38


shafts, upto floor five level excluding cost of
centring, shuttering, finishing and reinforcement
with 1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size).
5.11.1 Reinforced cement concrete work in chimneys, cum 2769.97
shafts, upto floor five level excluding cost of
centring, shuttering, finishing and reinforcement
with 1:1.5:3 (1 cement : 1.5 sand : 3 graded
stone aggregate 20 mm nominal size).

5.12 Reinforced cement concrete work in cum 2280.95


well-steining excluding the cost of centring,
shuttering, finishing and reinforcement with
1:2:4 (1 cement : 2 sand : 4 graded stone
aggregate 20mm nominal size)

5.12.1 Reinforced cement concrete work in cum 2535.53


well-steining excluding the cost of centring,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 sand : 3 graded stone
aggregate 20mm nominal size)

5.13 Reinforced cement concrete work in vertical and cum 2404.98


horizontal fins individually or forming box
louvers, facias and eaves boards upto floor five
level excluding the cost of centring, shuttering,
finishing and reinforcement with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size).

5.13.1 Reinforced cement concrete work in vertical and cum 2659.56


horizontal fins individually or forming box
louvers, facias and eaves boards upto floor five
level excluding the cost of centring, shuttering,
finishing and reinforcement with 1:1.5:3 (1
cement : 1.5 sand : 3 graded stone aggregate
20mm nominal size)

5.19 Providing, hoisting and fixing upto floor five cum 3304.33
level precast reinforced cement concrete in
string courses, bands, copings, bed plates,
anchor blocks, plain window sills and the like
including the cost of required centring,
shuttering, finishing smooth with 6mm thick
cement plaster 1:3 (1 cement : 3 sand) on
exposed surfaces complete but excluding cost
of reinforcement with 1:2:4 (1 cement : 2 sand :
4 graded stone aggregate 20mm nominal size).

5.26 Encasing rolled steel sections,in beams and cum 3001.39


columns, with cement concrete 1:2:4 (1 cement
:2 sand :4 grade stone aggregate 12.5mm
nominal size) including centring and shuttering
complete but excluding cost of reinforcement.

5.27 Encasing rolled steel section in grillages with cum 2234.74


cement concrete 1:2:4 (1 cement :2 sand: 4
graded stone aggregate 12.5mm nominal size)
upto floor two level including centring and
shuttering but excluding cost of expanded
metal and hangers.

5.29.3B Reinforcement for R.C.C. work including kg 42.77


straightening, cutting, bending, placing in
position and binding all complete - Thermo
Mechanical Treated Bars (TMT).

5.31 Deduct for omitting in R.C.C. work smooth sqm 43.01


finishing of the exposed surface with 6mm thick
cement mortar 1:3 (1 cement : 3 sand).

5.31A finishing the exposed surface of r.c.c. work with Sqm 43.01
6mm thick cement mortar 1:3 (1 cement : 3 sand)

5.32 Extra for rendering smooth the top of suspended sqm 33.96
floors,landings and staircases (treads and risers)
with cement mortar 1:2 ( 1 cement : 2 sand)
including a floating coat of neat cement and
protecting the surface with a layer of 7.5 cm of
earth laid over 15mm of fine sand incase of
suspended floor and bricks laid in mud mortar in
case of landings and steps including
subsequent removal and cleaning of the same.

5.42.1 Providing and laying in position machine cum 2684.69


batched, machine mixed and machine vibrated
design mix cement concrete of specified grade
for reinforced cement concrete structural
elements, excluding the cost of
centering, shuttering, finishing and
reinforcement. Including admistures in
recommended proportions as per IS 9103 to
accelerates retard setting of concrete improve
workability without impairing strength and
durability as per direction of Engineer-in-charge
-M-20 grade reinforced cement concrete –
All work upto plinth level.

5.42.2.1 Providing and laying in position machine cum 2798.17


batched, machine mixed and machine vibrated
design mix cement concrete of specified grade
for reinforced cement concrete structural
elements, excluding the cost of
centering, shuttering, finishing and
reinforcement. Including admistures in
recommended proportions as per IS 9103 to
accelerates retard setting of concrete improve
workability without impairing strength and
durability as per direction of Engineer-in-charge
-M-20 grade reinforced cement concrete -All
work from plinth level upto floor 5 level. Walls,
columns, pillars, posts and struts.
5.44.4 Add or deduct for providing richer or leaner cum 230.98
mixes respectively at all floor levels.- Providing
M-15 grade R.C.C instead of M-20 grade R.C.C.

5.29.1 Reinforcement for R.C.C. work including Deleted


straightening, cutting, bending, placing in
position and binding all complete - mild steel
and medium tensile steel bars.

5.29.3 Reinforcement for R.C.C work including Deleted


straightening, cutting, bending, placing in
position and binding all complete - cold
twisted bars.

5.29.3A Reinforcement for R.C.C work including Deleted


straightening, cutting, bending, placing in
position and binding all complete - Deformed
bars / M.S. bars.

5.29.4 Reinforcement for R.C.C work including Deleted


straightening ,cutting, bending, placing in
position and binding all complete - Hot rolled
deformed bars.
6 . Brick Work
Code Description Unit Rate

6.1.8 Brick work with bricks of class designation 35 in Cum 1552.55


foundation and plinth in - cement mortar 1:4
(1 cement : 4 sand).

6.1.10 Brick work with bricks of class designation 35 in Cum 1433.40


foundation and plinth in - cement mortar 1:6
(1 cement : 6 sand).

6.6.1 Extra for brick work in - square or rectangular Cum 109.49


pillars.

6.7 Extra for brick work with bricks of class Cum 150.48
designation 35 curved on plan upto a mean
radius not exceeding 6 metres.

6.9 Extra for cutting or chamfering of bricks to Rmt 5.04


required shape in masonry work.

6.13 Brick work 7cm thick with country bricks of class Sqm 148.35
designation 35 in cement mortar 1:3 (1 cement
: 3 coarse sand) in superstructure.

6.15 Brick work in plain arches in superstructure cum 2562.53


including centring and shuttering complete for
span upto 6 metres with bricks of class
designation 35 in cement mortar 1:3 (1 cement

6.18.4 Half brick masonry with bricks of class Sqm 183.02


designation 35 in foundation and plinth in -
cement mortar 1:4 (1 cement : 4 sand).

6.20A Extra for providing and placing in position 2nos. Sqm 38.27
6mm dia. M.S. bars at every third course of half
brick masonry (with brick class designation 35)

6.22 Providing brick band 10cm/7.0cm thick Rmt 7.77


5cm/5.7cm projected from wall face, in brick of
class designation 35 laid in cement mortar 1:4
(1 cement : 4 sand ).

6.32 Honey-comb brick work 10/11.4cm thick with Sqm 136.92


bricks of class designation 35 in cement mortar
1:4. (1 cement : 4 coarse sand ).

6.36 Providing 10cm/7cm thick and 5cm/5.7cm Rmt 7.85


projected string course with bricks of class
designation 35 in cement mortar 1:4 (1 cement

Pondicherry Page 11
6 . Brick Work
Code Description Unit Rate

6.37 Moulding and cornices with brick masonry in m/cm 0.88


cement mortar 1:4 (1 cement : 4 coarse sand)
(girth to be measured in cm and length in

6.41 Brick work with selected bricks of class cum 1462.57


designation 35 in exposed brick work including
making horizontal and vertical grooves 10mm
wide 12mm deep complete from ground level
upto plinth level in cement mortar 1:6 (1

Pondicherry Page 12
9 . Wood Work
Code Description Unit Rate

9.80 Providing and fixing M.S. round or square bars kg 37.71


at required spacings in wooden frames of
windows and clerestory windows.

9.81 Providing and fixing M.S.round or square bars kg 35.85


with M.S.flats at required spacings in wooden
frames of windows and clerestory windows.

9.82.1 Providing and fixing M.S. grills of required Kg 46.53


pattern in frames of windows etc. with M.S. flats,
square or round bars etc. all complete - fixed to
steel windows by welding.

9.82.2 Providing and fixing M.S. grills of required Kg 47.65


pattern in frames of windows etc. with M.S. flats,
square or round bars etc. all complete - fixed to
openings / wooden frames with rawl plugs.

9.87 Providing 40x5 mm flat iron hold fast 40 cm each 47.29


long including fixing to frame with 10mm
diameter bolts, nuts and wooden plugs and
embeddings in cement concrete block
30x10x15 cm 1:3:6 mix (1 cement : 3 sand : 6
graded stone aggregate 20mm nominal size).

Pondicherry Page 13
10 . Steel Work
Code Description Unit Rate

10.1 Structural steel work in single section fixed Kg 38.04


without connecting plate including cutting,
hoisting, fixing in position and applying a
priming coat of approved steel primer all

10.2 Structural steel work in single section fixed with kg 37.85


connecting plate including cutting, hoisting,
fixing in position and applying a priming coat
of approved steel primer all complete.

10.3 Structural steel work reveted or bolted in built kg 38.62


up section, trusses and framed work including
cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer all

10.4 Structural steel work welded in built up section, kg 38.06


trusses and framed work including cutting,
hoisting, fixing in position and applying a
priming coat of approved steel primer all

10.5 Providing and fixing in position collapsible Sqm 2107.38


steel shutters with vertical channels 20x10x2mm
and braced with flat iron diagonals 20x5mm
size with top and bottom rail of t-iron
40x40x6mm with 40mm dia, steel pulleys
complete with bolts, nuts, locking arrangements,
stoppers, handles, including applying a

10.6 Providing and fixing 1mm thick m.s. sheet Sqm 1602.87
sliding shutters with frame and diagonal braces
of 40x40x6mm angle iron, 3mm M.S.gusset
plates at the junction and corners, 25mm dia.
pulley, 40x40x6mm angle and t-iron guide at
the top and bottom respectively including
applying a priming coat of approved steel

10.7.1 Providing and fixing 1mm thick M.S. sheet door Sqm 1268.67
with frame of 40x40x6mm angle iron and 3mm
M.S. gusset plates at the junction and corners,
all nessesary fittings complete,including
applying a priming coat of approved steel
primer- using M.S. angles 40x40x6mm for

10.7.2 Providing and fixing 1mm thick M.S. sheet Sqm 1198.33
garage door with frame of 40x40x6mm angle
iron and 3mm M.S. gusset plates at the junction
and corners, all necessary fittings complete,
including applying a priming coat of approved
Pondicherry Page 14
10 . Steel Work
Code Description Unit Rate

steel primer- using flats 30x6mm for diagonal


braces and central cross piece.

10.14 Providing and fixing t-iron frames for doors, Kg 46.05


windows and ventilators of mild steel
tee-sections, joints mitred and welded with 15 x
3mm lugs 10cm long embedded in cement
concrete blocks 15 x 10 x 10cm of 1:3:6 (1
cement : 3 coarse sand : 6 graded stone
aggregate 20mm nominal size) or with wooden
plugs and screws or rawl plugs and screws or
with fixing clips or with bolts and nuts as
required, including fixing or necessary butt
hinges and screws and applying a priming coat

10.16.1 Steel work in built up tubular trusses including Kg 55.07


cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer,
welded and bolted including special shaped
washers etc. complete - hot finished welded
type tubes (conforming to is : 1161-1979).

10.16.2 Steel work in built up tubular trusses including Kg 58.00


cutting, hoisting, fixing in position in plates for
connecting truss members in purlins, tie runners
including providing necessary anchor bolts etc.
and applying a priming coat of approved steel
primer, welded and bolted including special
shaped washers etc. complete - hot finished
seamless type tubes (conforming to is :

10.16.3 Steel work in built up tubular trusses including Kg 55.07


cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer,
welded and bolted including special shaped
washers etc. complete - electric resistance or
induction butt welded tubes (conforming to is:

10.19 Providing and fixing M.S. fan clamp type-i of each 59.63
16mm dia m.s. bar bent to shape with hooked
ends in R.C.C. slabs during laying including
painting the exposed portion of loop, all as per
standard design complete.

10.20 Extra over rate of code no.10.19 for providing cm.heig 0.95
and fixing M.S. fan lamp type-ii as per design
in R.C.C. beams during laying towards the
additional height of the clamp due to beam rib.
Pondicherry Page 15
10 . Steel Work
Code Description Unit Rate

10.21 Providing and fixing circular cast iron box for each 68.01
ceiling fan clamp 140mm internal dia, 73mm
height, 5mm thick rim bottom and top lids,
1.5mm thick M.S. sheet with its top surface
backed for proper bonding top lid shall be
screwed into the cast iron box by means of
3.3mm dia round headed screws, one lock at
the corners. clamps shall be made of 12mm dia
M.S. bar bent to shape as per standard

10.21A Providing and fixing circular/hexagonal M.S. each 56.35


sheet ceiling fan box with of internal dia
140mm, 73mm height, 3mm thick rim bottom
and top lids, 1.5mm thick M.S. sheet. lid shall
be screwed into M.S. box by means of 3mm
round headed screws, clamps shall be made of
12mm dia M.S. bar bent to shape as per
standard drawing with over all length as 80cm.

10.31B supplying and fixing of steel grill work of m.s. Kg 42.93


angles,flats,squares and pipes including cost of
welding charges, fixing in position in masonry
walls with cement concrete 1:2:4 (1 cement : 2
course sand : 4 graded stone aggregate
12.5mm nnominal size) including one coat of
priming coat etc. complete.

10.32.1 Steel work welded in built up section / framed kg 43.04


work including cutting, hoisting, fixing in
position and applying a priming coat of
approved steel primer using structural steel etc.
as required - in stringes, treads, landings etc. of
stair cases including use of chequered plate

10.32.2 Steel work welded in built up sections/ framed Kg 40.45


work including cutting hoisting, fixing in
position and applying a priming coat of
approved steel primer using structural steel etc.
as required. - in gratings, frames, guard bar,
ladders, railings, brackets, gates and similar

10.33.1 Providing and fixing hand rail by welding etc. kg 53.40


to steel ladder railing, balcony railing &
staircase railing including applying a coat of
steel primer - M.S. tubes (medium) 40 mm

Pondicherry Page 16
10 . Steel Work
Code Description Unit Rate

10.33.3 Providing and fixing hand rail by welding etc. kg 66.85


to steel ladder railing, balcony railing &
staircase railing including applying a coat of
steel primer - G.I. pipes 40 mm nominal bore. (

Pondicherry Page 17
11 . Flooring
Code Description Unit Rate

11.1.1 Brick on edge flooring with bricks of class Sqm 218.45


designation 35 including cement slurry etc.
complete in cement mortar 1:4(1 cement: 4
coarse sand).

11.1.2 Brick on edge flooring with bricks of class Sqm 197.77


designation 35 including cement slurry etc.
complete in cement mortar 1:6 (1 cement:6

11.10.1 Cement plaster skirting (upto 30cm height) with Sqm 114.16
cement mortar 1:3 (1 cement : 3 sand) finished
with a floating coat of neat cement including
rounding of junctions with floor - 18mm thick.

11.10.2 Cement plaster skirting (upto 30cm height) with Sqm 121.18
cement mortar 1:3(1 cement :3 sand) finished
with a floating coat of neat cement including
rounding of junctions with floor - 21mm thick.

11.81 Providing and laying in floors fully vitrified tiles sqm 1186.94
of thickness not less than 10mm of size 60cm x
60cm of premium quality make of
Johnson/Regency/Naveen tiles of approved
colour and design laid on 20mm thick cement
mortar 1:4 (one cement : four sand ) including
grouting the joints with white cement and
matching pigment etc.,complete.

11.82 Providing and laying in floors fully vitrified tiles sqm 1380.13
of thickness not less than 10mm of size 60cm x
60cm of premium quality make of Bell tiles of
approved colour and design laid on 20mm thick
cement mortar 1:4 (one cement : four sand )
including grouting the joints with white cement
and matching pigment etc.,complete.

11.83 Providing and laying in floors fully vitrified tiles sqm 864.18
of thickness not less than 8mm of size 45cm x
45cm of premium quality make of
Johnson/Regency/Naveen tiles of approved
colour and design laid on 20mm thick cement
mortar 1:4 (one cement : four sand ) including
grouting the joints with white cement and
matching pigment etc.,complete.

11.84 Providing and laying in floors rectified tiles of sqm 662.60


thickness not less than 8mm of size 40.50cm x
40.50cm of premium quality make of Johnson/
Pondicherry Page 18
11 . Flooring
Code Description Unit Rate

Regency/ Naveen/ Kajaria tiles of approved


colour and design laid on 20mm thick cement
mortar 1:4 (one cement : four sand ) including
grouting the joints with white cement and
matching pigment etc.,complete.

11.84A Providing and laying in floors ceramic tiles of sqm 500.62


thickness not less than 6mm of size 30cm x
30cm of premium quality make of Johnson/
Regency/ Naveen/ Kajaria tiles of approved
colour and design laid on 20mm thick cement
mortar 1:4 (one cement : four sand ) including
grouting the joints with white cement and
matching pigment etc.,complete.

11.88 Tile work in skirting, risers of steps over 12mm Sqm 772.55
thick bed of cement mortar 1:3 (1 cement : 3
sand) and jointed with grey cement slurry @ 3.3
kg/sqm including pointing in white cement
mixed with pigment of matching shade
complete - Fully vitrified tiles 45x45cm 8mm
thick.Premium quality make of
Johnson/Regency/Naveen of approved colour

11.89 Tile work in skirting, risers of steps over 12mm Sqm 1272.02
thick bed of cement mortar 1:3 (1 cement : 3
sand) and jointed with grey cement slurry @ 3.3
kg/sqm including pointing in white cement
mixed with pigment of matching shade
complete - Fully vitrified tiles 60x60cm 10mm
thick.Premium quality make of Bell approved

11.90 Tile work in skirting, risers of steps over 12mm Sqm 1085.02
thick bed of cement mortar 1:3 (1 cement : 3
sand) and jointed with grey cement slurry @ 3.3
kg/sqm including pointing in white cement
mixed with pigment of matching shade
complete - Fully vitrified tiles 60x60cm 10mm
thick. Premium quality make of
Johnson/Regency/Naveen tiles of approved

11.91 Tile work in skirting, risers of steps over 12mm Sqm 577.42
thick bed of cement mortar 1:3 (1 cement : 3
sand) and jointed with grey cement slurry @ 3.3
kg/sqm including pointing in white cement
mixed with pigment of matching shade
complete - Rectified tiles 40.50x40.50cm 8mm
thick.Premium quality make of Johnson/
Pondicherry Page 19
11 . Flooring
Code Description Unit Rate

Regency/ Naveen/ Kajaria of approved colour


and design.
11.92 Tile work in skirting, risers of steps over 12mm Sqm 420.61
thick bed of cement mortar 1:3 (1 cement : 3
sand) and jointed with grey cement slurry @ 3.3
kg/sqm including pointing in white cement
mixed with pigment of matching shade
complete - Ceramic tiles 30x30cm 6mm
thick.Premium quality of Johnson/ Regency/
Naveen/ Kajaria of approved colour and design.

Pondicherry Page 20
12 . Roofing
Code Description Unit Rate

12.13 Extra for providing and fixing wind ties of 40 x 6 metre 62.24
mm flat iron section.

12.20 Providing flat iron brackets 50 x 3 mm size with metre 17.63


necessary bolts, nuts and washers etc. for fixing
asbestos cement / g.s sheets gutters with purlins.

12.33A Providing and laying pressed clay tiles (as per sqm 201.00
approved pattern 20 mm nominal thickness and
of approved size) on roofs jointed with cement
mortar 1:4 (1 cement : 4 coarse sand) mixed
with 2% integral water proofing compound laid
over a bed of 20 mm thick cement mortar 1:4 (1
cement : 4 coarse sand) and finsihed neat

Pondicherry Page 21
13 . Finishing
Code Description Unit Rate

13.8.2 12 mm cement plaster of mix - 1:4 (1 cement : sqm 54.52


4 fine sand)

13.8.3 12 mm cement plaster of mix - 1:5 (1 cement : sqm 51.51


5 fine sand).

13.8.4 12 mm cement plaster of mix - 1:6 (1 cement : sqm 47.65


6 fine sand).

13.9.2 15 mm cement plaster on the rough side of sqm 63.68


single or half brick wall of mix - 1:4 (1 cement :
4 fine sand).

13.9.4 15 mm cement plaster on the rough side of sqm 55.48


single or half brick wall of mix - 1:6 (1 cement :
6 fine sand).

13.10.2 20 mm cement plaster of mix - 1:4 (1 cement : sqm 77.97


4 fine sand).

13.10.4 20 mm cement plaster of mix - 1:6 (1 cement : sqm 67.29


6 fine sand).

13.14.1 12 mm cement plaster finished with a floating sqm 76.09


coat of neat cement - of mix - 1:3 (1 cement : 3
fine sand).

13.14.2 12 mm cement plaster finished with a floating sqm 69.22


coat of neat cement - of mix - 1:4 (1 cement : 4
fine sand).

13.16.1 20 mm cement plaster finished with a floating sqm 103.36


coat of neat cement of mix 1:3 (1 cement : 3

13.16.2 20 mm cement plaster finished with a floating sqm 92.68


coat of neat cement of mix - 1:4 (1 cement : 4

13.24.1 6 mm cement plaster to ceiling of mix - 1:3 (1 sqm 43.01


cement : 3 fine sand).

13.25 6 mm cement plaster 1:3 (1 cement : 3 fine sqm 59.61


sand) finished with a floating coat of neat
cement and thick coat of lime wash on top of
walls when dry for bearing of R.C.C. slabs and

13.29.1 18 mm cement lime plaster in two coats under sqm 78.33


layer 12 mm cement plaster 1:5 (1 cement : 5
sand) finished with 6 mm cement lime plaster of
Pondicherry Page 22
13 . Finishing
Code Description Unit Rate

mix 1:1:6 (1 cement : 1 lime putty: 6 fine


sand).
13.50.1 12 mm thick plain cement mortar bands in unit 1.00
cement mortar 1:4 (1 cement : 4 fine sand) -
flush band (cost for 1 m long/1 cm wide).

13.50.3 12 mm thick plain cement mortar bands in unit 1.21


cement mortar 1:4 (1 cement : 4 fine sand) -
raised band. (cost of 1 m long/1 cm wide band).

13.51A Providing and fixing on wall face with broken sqm. 146.74
glasses in C.M. 1:4 (one cement : 4 sand)

13.51B 15 mm thick plain cement plaster band of width metre 6.08


100mm with cement mortar 1:4 (1 cement : 4
sand). - raised band.

13.79.1 Finishing walls with water proofing cement sqm 37.45


paint of approved brand and manufacture and
of required shade to give an even shade - new
work (three or more coats).

Pondicherry Page 23
14 . Repairs To Buildings
Code Description Unit Rate

14.1.1 Repairs to plaster of thickness 12mm to 20mm sqm 80.88


in patches of area 2.5 sqm and under including
cutting the patch in proper shape and preparing
and plastering the surface of the walls
complete including disposal of rubbish to the
dumping ground within 50 metres lead: with
cement mortar 1:4 (1 cement, 4 fine sand).

14.42 Providing and fixing M.S. round or square bars kg 37.71


at required spacings in wooden frames of
windows and clerestory windows.

14.43 Providing and fixing M.S.round or square bars kg 35.77


with M.S.flats at required spacings in wooden
frames of windows and clerestory windows.

14.81.2 Finishing walls with water proofing cement sqm 22.03


paint of approved brand and manufacture and
of required shade to give an even shade - old
work (one or more coats).

Pondicherry Page 24
16 . Miscellaneous Building Works
Code Description Unit Rate

16.2.1 Making plinth protection with bricks of class sqm 262.84


designation 35 laid on edge in cement mortar
1:6 ( 1 cement : 6 coarse sand) with 12mm thick
bed of cement mortar 1:6 (1 cement : 6 coarse
sand) over 75mm bed of dry brick aggregate
40mm nominal size rammed, consolidated and
grouted with fine sand and the top of bricks
pointed with cement mortar 1:3 (1 cement : 3

16.15 Brick edging 7cm wide 11.4cm deep to plinth metre 11.62
protection with bricks of class designation 35
including grouting with cement mortar 1:4 (1
cement : 4 fine sand).

16.24 Providing and fixing factory made PVC door metre 245.95
frame manufactured by M/s. Rajshri or
equivalent of size 50x47mm with a wall
thickness of 5mm, made out of extruded 5mm
rigid PVC foam sheet mitred at corners and
joined with 2 Nos. of 150mm long brackets of
15x15mm M.S. square tube, the vertical door
profiles to be reinforced with 19x19mm M.S.
square tube of 19 guage, EPDM rubber gasket
weather seal to be provided through out the
frame. The door frame to be fixed to the wall
using M.S. screws of 65/100mm size complete
as per manufacturers specification and direction
of Engineer-in-Charge.
16.25 Providing and fixing 30mm thick factory made sqm 1753.00
PVC rigid foam panelled door shutters
manufactured by M/s. Rajshri or equivalent
made from M.S. tube of 19 gauge thickness,
size 19x19mm for styles and 15x15mm for top
and bottom fails, covered with heat moulded
PVC "C" channel of 5mm thick sheet and
30x50mm wide to to form styles and 5mm thick
and 75mm wide PVC sheets for top rail, lock rail
and bottom rail on either side and 5mm thick,
20mm wide cross PVC sheet as gap insert for
top rail and bottom rail, panelling of 5mm thick
PVC sheet fitted in the M.S. frame welded /
sealed to the styles and rails with 5x30mm PVC
sheet beading on either side and joined
together with solvent cement adhesive etc.,
complete as per manufacturerrs specification
and direction of Engineer-in-Charge fixed to
frames with 4 Nos. M.S. powder coated butt
hinges (For W.C. and bathroom shutters)
Pondicherry Page 25
16 . Miscellaneous Building Works
Code Description Unit Rate

16.26 Providing and fixing 30mm thick factory made sqm 2181.15
PVC rigid foam panelled door shutters
manufactured by M/s. Rajshri or equivalent
made from M.S. tube of 19x19mm, 19 gauge
for styles and 15x15mm for top and bottom
rails, covered with heat moulded prelaminated
PVC "C" channel of 5mm thick sheet and
30x50mm wide to form styles and 5mm thick
and 75mm wide prelaminated PVC sheets for
top rail, lock rail and bottom rail on either side
and 5mm thick, 20mm wide cross PVC sheet as
gap insert for top rail and bottom rail, panelling
of 5mm thick PVC sheet prelaminated on both
sides fitted in the M.S. frame welded / sealed to
the styles and rails with 5x30mm prelaminated
PVC sheet beading on either side and joined
together with solvent cement adhesive etc.
complete as per manufacturers specification
and direction of Engineer-in-Charge fixed to
frames with 4 Nos. M.S. powder coated butt
16.27 Providing and fixing PVC rigid foam sheet 1mm sqm 316.25
thick manufactured by M/s. Rajshri or
equivalent on existing door shutters (bathroom
and W.C. doors) using synthetic rubber based
adhesive (Fevicol SR 998 or equivalen)

16.28 Providing and fixing prelaminated PVC rigid sqm 820.90


foam sheet manufactured by M/s. Rajshri or
equivalent wall panelling of thickness 5mm
stuck on inner frame work of 35mm wide strips of
5mm thick PVC rigid foam sheet. The strips
should have in their centre a groove of 6mm
width and 2mm depth for sinking the head of
the screw used to fix the strips to the wall and
should be placed vertically at equal intervals of
405/407mm centre to centre. The PVC strips to
be fixed to the wall using 65mm long M.S.
screws through the groove in the stip by using
PVC fasteners, the distance between two screws
shall not be more than 300mm. A groove of
2mm to be left at the joint of two panels for
16.38 Providing and fixing gi pipe handrail with metre 452.10
40mm GI pipe supported on 25x6mm MS flat
welded with 20mm square ms bars at 60cm
centre to centre to a total height of 90cm from
the finished floor level and welded with 20 mm
square ms bars horizantally at mid height of
handrail. the entire assembly shall be fixed in
Pondicherry Page 26
16 . Miscellaneous Building Works
Code Description Unit Rate

the concrete or brick work as directed. the cost


shall also include welding, painting ms bars,
flats with two coats of ready mixed paint over
one coat of ready mixed primer.

16.38A Supply, delivery and fixing of GI handrail metre 582.10


consisting of 40mm dia GI pipe post class B and
32mm dia class B GI pipe horizontal with 6mm
thick MS plate at the base and fixing in
concrete with 16mm dia J bolt etc. complete as
per departmental drawings including cost and
conveyance of all materials, fabrication

16.59 Providing and fixing of M.S rungs of 25cm wide each 117.12
of required shape using 16mm dia. M.S rods at
required spacing fixing in cement concrete
block of size 65x23x15cm in C.C 1:2:4( 1
cement :2 sand : 4 HBG 20mm metal) including
painting with required ready mixed paint (two
or more coats) over one coat of primer of
approved quality all as directed by the

16.81 Supplying at site 1.8m long R.C.C standard each 277.33


posts with wooden plugs or 6mm bar nibs. - RCC
1:2:4 (one cement, two sand and four graded
stone aggregate of 20mm nominal size)

16.82 Supplying at site R.C.C standard struts 2m long each 225.72


- RCC 1:2:4 (one cement, two sand and four
graded stone aggregate of 20mm nominal size)

16.87 Supplying at site angle iron post & stut of kg 38.82


required size including bottom to be split and
bend at right angle in opposite direction for
10cm length and drilling holes upto 10mm dia

Pondicherry Page 27
20 . Water Supply
Code Description Unit Rate

20.2.1.1 Providing and fixing G.I. pipes complete with metre 98.39
G.I. fittings and clamps, including cutting and
making good the walls etc. (internal work)
exposed on walls - 15mm nominal bore (1.22

20.2.1.2 Providing and fixing G.I. pipes complete with metre 123.16
G.I. fittings and clamps, including cutting and
making good the walls etc.(internal work)
exposed on walls - 20mm nominal bore (1.58

20.2.1.3 Providing and fixing G.I.pipes complete with metre 180.10


G.I. fittings and clamps, including cutting and
making good the walls etc. (internal work)
exposed on wall - 25mm nominal bore (2.44

20.2.1.5 Providing and fixing G.I.pipes complete with metre 266.05


G.I. fittings and clamps, including cutting and
making good the walls etc. (internal work) -
40mm nominal bore (3.61 kg/m).

20.2.2.1 Providing and fixing G.I. pipes complete with metre 126.35
G.I. fittings and clamps, including cutting and
making good the walls etc. (internal work)
Concealed pipe including painting with anti
corrosive bitumastic paint, cutting chases and
making good the wall - 15 mm nominal bore

20.2.2.2 Providing and fixing G.I. pipes complete with metre 149.35
G.I. fittings and clamps, including cutting and
making good the walls etc. (internal work)
Concealed pipe including painting with anti
corrosive bitumastic paint, cutting chases and
making good the wall - 20 mm nominal bore.

20.3.1 Providing and fixing G.I. pipe complete with metre 108.90
G.I. fittings including trenching and refilling
etc., (extranal work) - 15 mm dia nominal bore

20.3.2 Providing and fixing G.I. pipe complete with metre 129.30
G.I. fittings including trenching and refilling
etc., (extranal work) - 20 mm dia nominal bore

20.3.3 Providing and fixing G.I pipes complete with metre 156.84
G.I fittings including trenching and refilling and
etc. (external work ) - 25 mm dia nominal bore

20.3.5 Providing and fixing G.I. pipes complete with metre 225.25
G.I. fittings including trenching and refilling etc.
Pondicherry Page 28
20 . Water Supply
Code Description Unit Rate

(external work) - 40mm nominal bore.

20.3.8 Providing and fixing G.I. pipes complete with metre 469.96
G.I. fittings including trenching and refilling etc.
(external work) - 80mm nominal bore.

20.50.2 Constructing masonry Chamber 30 x 30 x 50 each 401.05


cm, inside with 35 class designation brick work
in cement mortar 1:5 (1 cement : 5 fine sand)
for stop cock, with C.I. surface box 100 x 100 x
75 mm (inside) with hinged cover fixed in
cement concrete slab 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm
nominal size) necessary excavation foundation
concrete 1:5:10 (1 cement :5 fine sand : 10
graded stone aggregate 40 mm nominal size)
and inside plastering with cement mortar 1:3 (1
cement : 3 sand) 12 mm thick finished with a
floating coat of neat cement complete as per
standard design - with brick class designation
20.51.2 Constructing masonry Chamber 60 x 60 x 75 cm each 2594.08
inside with 35 class designation brick work in
cement mortar 1:5 (1 cement : 5 fine sand) for
sluice valve, with C.I. surface box 100 mm top
diameter 160 mm bottom diameter and 180
mm deep (inside) with chained lid and R.C.C.
top slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size)
necessary excavation, foundation concrete
1:5:10 (1 cement : 5 fine sand : 10 graded
stone aggregate 40 mm nominal size) and
inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick finished
with a floating coat of neat cement complete as
per standard design - with brick class
designation 35.
20.52.2 Constructing masonry Chamber 90 x 90 x100 each 4431.41
cm inside with 35 class designation brick work in
cement mortar 1:5 (1 cement : 5 fine sand) for
sluice valve, with C.I. surface box 100 mm top
diameter 160 mm bottom diameter and 180
mm deep (inside) with chained lid and R.C.C.
top slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size)
necessary excavation, foundation concrete
1:5:10 (1 cement : 5 fine sand : 10 graded
stone aggregate 40 mm nominal size) and
inside plastering with cement mortar 1:3 (1
Pondicherry Page 29
20 . Water Supply
Code Description Unit Rate

cement : 3 coarse sand) 12 mm thick finished


with a floating coat of neat cement complete as
per standard design - with brick class
designation 35.
20.53.2 Constructing masonry Chamber each 6192.38
120x120x100cm inside with 35 class
designation brick work in cement mortar 1:5 (1
cement : 5 fine sand) for sluice valve, with C.I.
surface box 100mm top diameter 160mm
bottom diameter and 180mm deep (inside) with
chained lid and R.C.C top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) necessary
excavation foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone
aggregate 40mm nominal size) and inside
plastering with cement mortar 1:3 (2 cement : 3
coarse sand) 12mm thick finished with a floating
coat of neat cement complete as per standard
design - with bricks class designation 35
20.54.2 Constructing masonry Chamber 60 x 60 x 75 cm each 2547.58
inside with 35 class designation brick work in
cement mortar 1:5 (1 cement : 5 fine sand) for
fire hydrants, with C.I. surface box 350 x 550
mm top and 165 mm deep (inside) with
chained lid and R.C.C. top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) necessary
excavation, foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick finished with a
floating coat of neat cement complete as per
standard design - with brick class designation 35
20.55.2 Constructing masonry chamber 60 x 45 x 50 cm each 2547.67
inside with 35 class designation brick work in
cement mortar 1:5 (1 cement : 5 fine sand) for
water meter complete, with C.I. double flap
surface box 400 x 200 x 200 mm (inside) with
locking arrangement and R.C.C. top slab 1:2:4
mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) necessary
excavation, foundation concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3
course sand) 12 mm thick finished with a
Pondicherry Page 30
20 . Water Supply
Code Description Unit Rate

floating coat of neat cement complete as per


standard design - with brick class designation 35
20.79.1 Providing and filling sand of grading zone V or metre 25.28
coarser grade alround the G.I. pipes in external
work - 15 mm diameter pipe.

20.79.2 Providing and filling sand of grading zone V or metre 25.62


coarser grade alround the G.I. pipes in external
work - 20 mm diameter pipe.

20.79.3 Providing and filling sand of grading zone V or metre 26.30


coarser grade alround the G.I. pipes in external
work - 25 mm diameter pipe.

20.79.4 Providing and filling sand of grading zone V or metre 26.99


coarser grade alround the G.I. pipes in external
work - 32mm diameter pipe.

20.79.5 Providing and filling sand of grading zone V or metre 27.33


coarser grade alround the G.I. pipes in external
work - 40 mm diameter pipe.

20.79.6 Providing and filling sand of grading zone V or metre 28.35


coarser grade alround the G.I. pipes in external
work - 50 mm diameter pipe.

20.79.7 Providing and filling sand of grading zone V or metre 44.75


coarser grade alround the G.I. pipes in external
work - 65 mm diameter pipe.

20.79.8 Providing and filling sand of grading zone V or metre 46.11


coarser grade alround the G.I. pipes in external
work - 80 mm diameter pipe.

20.85 Providing and fixing to filter and lowering to metre 219.23


proper level 40 mm G.I. pipe for tubewell
including cleaning and priming the tubewell.

Pondicherry Page 31
21 . Drainage
Code Description Unit Rate

21.2.1 Providing and laying cement concrete 1:5:10 (1 metre 221.48


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) alround S.W.
pipes including bed concrete as per standard
design - 100 mm diameter.

21.2.2 Providing and laying cement concrete 1:5:10 (1 metre 270.86


cement : 5 coarse sand : 10 graded stone
aggregate 40mm nominal size) alround S.W.
pipes including bed concrete as per standard
design - 150mm diameter.

21.2.3 Providing and laying cement concrete 1:5:10 (1 metre 315.76


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) alround S.W.
pipes including bed concrete as per standard
design - 200 mm diameter.

21.2.4 Providing and laying cement concrete 1:5:10 (1 metre 345.69


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) alround S.W.
pipes including bed concrete as per standard
design - 230 mm diameter.

21.2.5 Providing and laying cement concrete 1:5:10 (1 metre 365.14


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) alround S.W.
pipes including bed concrete as per standard
design - 250 mm diameter.

21.3.1 Providing and laying cement concrete 1:5:10 (1 metre 105.26


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) upto haunches
of S.W. pipes including bed concrete as per
standard design - 100 mm diameter.

21.3.2 Providing and laying cement concrete 1:5:10 (1 metre 170.60


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) upto haunches
of S.W. pipes including bed concrete as per
standard design - 150 mm diameter.

21.3.3 Providing and laying cement concrete 1:5:10 (1 metre 200.53


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) upto haunches
of S.W. pipes including bed concrete as per
standard design - 200 mm diameter.

Pondicherry Page 32
21 . Drainage
Code Description Unit Rate

21.3.4 Providing and laying cement concrete 1:5:10 (1 metre 219.98


cement : 5 coarse sand : 10 graded stone
aggregate 40mm nominal size) upto haunches
of S.W. pipes including bed concrete as per
standard design - 230 mm diameter.

21.3.5 Providing and laying cement concrete 1:5:10 (1 metre 233.45


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) upto haunches
of S.W. pipes including bed concrete as per
standard design - 250 mm diameter.

21.4.1.2 Providing and fixing square-mouth S.W. gully each 578.19


trap grade `A' complete with C.I. grating brick
masonry chamber with bricks of class
designation 35 and water tight C.I. cover with
frame of 300 x 300 mm size (inside) the weight
of cover to be not less than 4.5 kg. and frame to
be not less than 2.70 kg. as per standard design

21.4.2.2 Providing and fixing square-mouth S.W. gully each 591.53


trap grade `A' complete with C.I. grating brick
masonry chamber with bricks of class
designation 35 and water tight C.I. cover with
frame of 300 x 300 mm size (inside) the weight
of cover to be not less than 4.5 kg. and frame to
be not less than 2.70 kg. as per standard design

21.6.4 Providing and laying non-pressure NP2 class metre 503.11


(light duty) R.C.C. pipes with collars jointed with
stiff mixture of cement mortar in the proportion
of 1:2 (1 cement : 2 fine sand) including testing
of joints etc. complete - 300 mm dia.

21.6.5 Providing and laying non-pressure NP2 class metre 740.35


(light duty) R.C.C. pipes with collars jointed with
stiff mixture of cement mortar in the proportion
of 1:2 (1 cement : 2 fine sand) including testing
of joints etc. complete - 450 mm dia.

21.6.6 Providing and laying non-pressure NP2 class metre 433.39


(light duty) R.C.C. pipes with collars jointed with
stiff mixture of cement mortar in the proportion
of 1:2 (1 cement : 2 fine sand) including testing
of joints etc. complete - 500 mm dia.

21.6.10 Providing and laying non-pressure NP2 class metre 1535.90


(light duty) R.C.C. pipes with collars jointed with
Pondicherry Page 33
21 . Drainage
Code Description Unit Rate

stiff mixture of cement mortar in the proportion


of 1:2 (1 cement : 2 fine sand) including testing
of joints etc. complete - 900 mm dia.
21.11.1.2 Constructing brick masonry manhole with 35 each 3252.50
class designation bricks in cement mortar 1:4 (1
cement : 4 coarse sand ) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4
coarse sand : 8 graded stone aggregate 40 mm
nominal size) inside plastering 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand )
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a
floating coat of neat cement complete as per
standard design - inside size 90 x 80 cm and
45 cm deep including C.I. cover with frame
(light duty) 455 x 610 mm internal dimensions
total weight of cover and frame to be not less
than 38 kg. (weight of cover 23 kg. and weight
of frame 15 kg) - with bricks of class
21.11.2.2 Constructing brick masonry manhole with 35 each 3524.19
class designation bricks in cement mortar 1:4 (1
cement : 4 coarse sand ) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4
coarse sand : 8 graded stone aggregate 40mm
nominal size) inside plastering 12mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand )
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) neatly finished
complete as per standard design - inside size
90 x 80cm and 60cm deep including C.I. cover
with frame (light duty) 455 x 610mm internal
dimensions total weight of cover and frame to
be not less than 38 kg. (weight of cover 23 kg.
and weight of frame 15 kg.) - with bricks of
21.11.3.2 Constructing brick masonry manhole with 35 each 6260.57
class designation bricks in cement mortar 1:4 (1
cement : 4 coarse sand ) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4
Pondicherry Page 34
21 . Drainage
Code Description Unit Rate

coarse sand : 8 graded stone aggregate 40 mm


nominal size) inside plastering 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand )
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a
floating coat of nean cement complete as per
standard design - inside size 120 x 90 cm and
90 cm deep including C.I. cover with frame
(medium duty) 500 mm internal diameter, total
weight of cover and frame to be not less than
116 kg. (weight of cover 58 kg. and weight of
frame 58 kg) - with bricks of class designation

21.11.4.2 Constructing brick masonry manhole with 35 each 7473.82


class designation bricks in cement mortar 1:4 (1
cement : 4 coarse sand ) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4
coarse sand : 8 graded stone aggregate 40 mm
nominal size) inside plastering 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand )
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a
floating coat of nean cement complete as per
standard design - inside size 120 x 90 cm and
90 cm deep including C.I. cover with frame
(heavy duty) 560 mm internal diameter, total
weight of cover and frame to be not less than
208 kg. (weight of cover 108 kg. and weight of
frame 100 kg) - with bricks of class designation
21.12.1.2 Extra for depth for manholes - size of 90 x 80 metre 1795.75
cm - with bricks of class designation 35.

21.12.2.2 Extra for depth for manholes - size 120 x 90 cm metre 2151.61
- with bricks of class designation 35.

21.17.2 Providing M.S. foot rests including fixing in each 95.70


manholes with 20 x 20 x 10 cm cement
concrete blocks 1:3:6 (1 cement : 3 coarse sand
: 6 graded stone aggregate 20 mm nominal
size) as per standard design - with 20 mm

21.28.2 Constructing brick masonry road gully chamber each 1727.94


Pondicherry Page 35
21 . Drainage
Code Description Unit Rate

45x45x77.5cm with bricks of class designation


35 in cement mortar 1:5 (1 cement : 5 fine
sand) with precast R.C.C. vertical grating
complete as per standard design - with class
21.29.2 Constructing brick masonry road gully chamber each 3172.13
110x50x77.5cm with bricks of class designation
35 in cement mortar 1:5 (1 cment : 5 fine sand)
including 500x450mm precast R.C.C. horizontal
grating with frame and vertical grating
complete as per standard design:-with class
designation 35 bricks.

21.33.2.2 Constructing brick masonry chamber for each 1980.99


underground C.I.inspection chamber and bends
with 35 class designation bricks in cement
mortar 1:5 (1 cement : 5 fine sand) C.I. cover
with frame (light duty) 455x 610 mm internal
dimensions, total weight of cover with frame to
be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size)
foundation concrete 1:5:10 (1 cement : 5 fine
sand : 10 graded stone aggregate 40 mm
nominal size), inside plastering 12 mm thick
with cement mortar 1:3 (1 cement :3 coarse
sand) finished smooth with a floating coat of
neat cement on walls and bed concrete etc.
complete as per standard design - inside
dimensions 500 x 700 mm and 45 cm deep for
21.33.3.2 Constructing brick masonry chamber for each 2329.35
underground C.I.inspection chamber and bends
with 35 class designation bricks in cement
mortar 1:5 (1 cement : 5 sand) C.I. cover with
frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to
be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg) R.C.C. top slab with
1:2:4 mix (1 cement : 2 sand : 4 graded stone
aggregate 20 mm nominal size) foundation
concrete 1:5:10 (1 cement : 5 sand : 10 graded
stone aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar 1:3
(1 cement :3 sand) finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete as per standard design -
inside dimensions 600 x 850 mm and 45 cm
deep for pipe line with three or more inlets.
Pondicherry Page 36
21 . Drainage
Code Description Unit Rate

21.34.1.2 Extra for depth beyond 45 cm or brick masonry metre 1203.95


chamber - for 455x610 mm size with bricks of
class designation 35.

21.34.2.2 Extra for depth beyond 45 cm or brick masonry metre 1313.81


chamber - for 500x700 mm size with bricks of
class designation 35.

21.34.3.2 Extra for depth beyond 45 cm or brick masonry metre 1530.46


chamber - for 600 x 850 mm size with bricks of
class designation 35.

21.35.1.2 Constructing brick masonry open surface drain metre 207.14


with bricks of class designation 35 in cement
mortar 1:4 (1 cement : 4 fine sand) including
earth excavation, 10 cm thick bed concrete
1:5:10 (1 cement : 5 fine sand : 10 graded
stone aggregate 40 mm nominal size and 25
mm thick cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 12.5
mm nominal size) for filling haunches including
12 mm cement plaster 1:4 (1 cement : 4 coarse
sand) with a floating coat of neat cement
inside the drain, its top and exposed side
including disposal of surplus earth complete as
per standard design - 10 cm drain 20 cm
average depth with class designation 35 bricks.
21.35.2.2 Constructing brick masonry open surface drain metre 219.81
with class designation 35 in cement mortar 1:4
(1 cement : 4 fine sand) including earth
excavation, 10 cm thick bed concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size and 25 mm
thick cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 12.5
mm nominal size) for filling haunches including
12 mm cement plaster 1:4 (1 cement : 4 coarse
sand) with a floating coat of neat cement
inside the drain, its top and exposed side
including disposal of surplus earth complete as
per standard design - 15 cm drain 20 cm
average depth - with brick class designation 35.
21.35.3.2 Constructing brick masonry open surface drain metre 298.65
with class designation 35 in cement mortar 1:4
(1 cement : 4 fine sand) including earth
excavation, 10 cm thick bed concrete 1:5:10 (1
cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size and 25 mm
Pondicherry Page 37
21 . Drainage
Code Description Unit Rate

thick cement concrete 1:2:4 (1 cement : 2


coarse sand : 4 graded stone aggregate 12.5
mm nominal size) for filling haunches including
12 mm cement plaster 1:4 (1 cement : 4 coarse
sand) with a floating coat of neat cement
inside the drain, its top and exposed side
including disposal of surplus earth complete as
per standard design - 25 cm drain 30 cm
average depth - with brick class designation 35.

Pondicherry Page 38
22 . Miscellaneous
Code Description Unit Rate

22.9.2 Cutting holes upto 30 x 30 cm in walls each 62.68


including making good the same with bricks of
class designation 35.

22.27.1.1 Drilling of borewells any where in Pondicherry 1 metre 418.00


including tranportation from one place in
alluvial soil sedimentary strata of clay and sand
stone, shale pebbles, boulders etc. by first
taking a pilot of 140mm , 150mm / 200mm and
then enlarging to required dia by direct or
reverse rotary mud circulation method, using
contractor's rig fuel labour drilling benetonite
mud and water required for drilling at the site
shown by the Engineer-in-charge including
contruction of mud pit (water available within a
lead of 1.5Km) using rotary rig. Drilling of
140/150/200mm pilot bore. Upto 60 mts. Depth
ending below ground level
22.27.1.2 Drilling of borewells any where in Pondicherry 1 metre 452.00
including tranportation from one place in
alluvial soil or sedimentary strata of clay and
sand stone, shale, pebbles, boulders etc. by first
taking a pilot of 140mm , 150mm / 200mm
and the enlarging to required dia by direct or
reverse rotary mud circulation method, using
contractor's rig fuel labour drilling benetonite
mud and water required for drilling at the site
shown by the Engineer-in-charge including
contruction of mud pit (water available within a
lead of 1.5Km) using rotary rig. Drilling of
140/150/200mm pilot bore. From 60mts and
upto 90 mts depth ending from ground level
22.27.1.3 Drilling of borewells any where in Pondicherry 1 metre 480.00
including tranportation from one place in
alluvial soil or sedimentary strata of clay and
sand stone, shale, pebbles, boulders etc. by first
taking a pilot of 140mm , 150mm / 200mm
and the enlarging to required dia by direct or
reverse rotary mud circulation method, using
contractor's rig fuel labour drilling benetonite
mud and water required for drilling at the site
shown by the Engineer-in-charge including
contruction of mud pit (water available within a
lead of 1.5Km) using rotary rig. Drilling of
140/150/200mm pilot bore. From 90 mts and
upto 120 mts depth ending from ground level
22.27.1.4 Drilling of borewells any where in Pondicherry 1 metre 504.00
including tranportation from one place in
Pondicherry Page 39
22 . Miscellaneous
Code Description Unit Rate

alluvial soil or sedimentary strata of clay and


sand stone, shale, pebbles, boulders etc. by first
taking a pilot of 140mm , 150mm / 200mm
and the enlarging to required dia by direct or
reverse rotary mud circulation method, using
contractor's rig fuel labour drilling benetonite
mud and water required for drilling at the site
shown by the Engineer-in-charge including
contruction of mud pit (water available within a
lead of 1.5Km) using rotary rig. Drilling of
140/150/200mm pilot bore. From 120 mts and
upto 150 mts depth ending from ground level
22.27.2.1 Reaming from 140/150 mm dia pilot bore to 1 metre 105.00
300mm dia bore as directed by the
Engineer-in-charge. Upto 60 mts depth ending

22.27.2.2 Reaming from 140/150 mm dia pilot bore to 1 metre 111.00


300mm dia bore as directed by the
Engineer-in-charge. From 60 mts and upto 90
mts depth ending from ground level

22.27.2.3 Reaming from 140/150 mm dia pilot bore to 1 metre 119.00


300mm dia bore as directed by the
Engineer-in-charge. From 90 mts and upto 120
mts depth ending from ground level

22.27.2.4 Reaming from 140/150 mm dia pilot bore to 1 metre 121.00


300mm dia bore as directed by the
Engineer-in-charge. From 120 mts and upto
150 mts depth ending from ground level

22.27.3.1 Reaming from 200 mm dia pilot bore to 1 metre 118.00


350mm dia bore as directed by the
Engineer-in-charge. Upto 60 mts depth ending

22.27.3.2 Reaming from 200 mm dia pilot bore to 1 metre 125.00


350mm dia bore as directed by the
Engineer-in-charge. From 60 mts and upto 90
mts depth ending below ground level

22.27.3.3 Reaming from 200 mm dia pilot bore to 1 metre 133.00


350mm dia bore as directed by the
Engineer-in-charge. From 90 mts and upto 120
mts depth ending below ground level

22.27.3.4 Reaming from 200 mm dia pilot bore to 1 metre 137.00


350mm dia bore as directed by the
Engineer-in-charge. From 120 mts and upto
Pondicherry Page 40
22 . Miscellaneous
Code Description Unit Rate

150 mts depth ending below ground level

22.27.4.1 Reaming from 200 mm dia pilot bore to 1 metre 162.00


400/450mm dia bore as directed by the
Engineer-in-charge. Upto 60 mts depth ending

22.27.4.2 Reaming from 200 mm dia pilot bore to 1 metre 181.00


400/450mm dia bore as directed by the
Engineer-in-charge. From 60 mts and upto 90
mts depth ending below ground level

22.27.4.3 Reaming from 200 mm dia pilot bore to 1 metre 193.00


400/450mm dia bore as directed by the
Engineer-in-charge. From 90 mts and upto 120
mts depth ending below ground level

22.27.4.4 Reaming from 200 mm dia pilot bore to 1 metre 205.00


400/450mm dia bore as directed by the
Engineer-in-charge. From 120 mts and upto
150 mts depth ending below ground level

22.27.5 Charges for developing the borewells with air 1 hour 616.00
compressor of 600 CFM capacity (minimum 8
hours) including transportation labour and fuel
charges for compressor as directed by the
Engineer-in-charge and conducting yield test by
'v' Notch Methods

Pondicherry Page 41
30 . Irrigation
Code Description Unit Rate

30.3 Collection of earth and banking the earth in cum 157.89


layers not exceeding 20cm in depth breaking
clods, watering, rolling each layers with ½ tonne
roller or wooden or steel rammers and dressing
up in embankments for roads flood banks,
marginal banks and guide banks etc and lift
upto 1.5m in all kinds of soil. The quantity of
the fill shall be calculated based on levels and
then reduced by 10% for the purpose of

30.6 Conveyence of excavated earth within a lead of cum 53.25


1KM radius, beyond the initial lead of 50m
and filling up in embankments for roads, flood
banks, marginal banks and guide banks etc., in
all kinds of soils. The quantity of conveyed
earth shall be calculated based on levels and
the total quantity shall be reduced by 20% for
the purpose of payment.

30.9 Supplying and placing in position HDPE bag 13.65


cement bags filled with sand for breach closing
/ diversion arrangement. The cost includes the
cost of empty HDPE bags, labour charges for
filling the bags and placing in position,
removing the bags from site after completing

30.11 Supplying with gravel for apron and rivetment. cum 222.48

Pondicherry Page 42