Sie sind auf Seite 1von 2

A New Gold Standard in Infusion Management

BodyGuard 121
Twins
Ambulatory Dual Channel
Infusion Pump

Enter a new era in ambulatory infusion • 2 channel, multi-protocol infusion


management with the BodyGuard 121 Twins pump
infusion pump. BodyGuard offers a comprehensive
range of features designed to maximise safe, • Lightweight & Compact –the smallest,
economic and simple administration of infusion, lightest bed-side pump in its class.
thanks to its dual channels and multi programs. • Pole-mountable mains or
rechargeable Li-ion battery operated
The BodyGuard 121 Twins offers five programs: to allow patient ambulation.
Continuous, 25 Steps, TPN, Intermittent and PCA.
• Piston pump mechanism ensures
BodyGuard is light, compact & robust ensuring it superior accuracy and linearity of infusion
can be used in a wide variety of treatment settings even at low delivery rates.
such as hospital, homecare, transport or emergency • Post-occlusion Bolus Reduction System
medicine. prevents false bolus after occlusion.
This flexibility is further enhanced by the • Comprehensive range of pump
rechargeable, internal Li-Ion battery and a mains accessories including carry pouch
charger. A piston pump mechanism ensures suitable for 3000 ml.
unparalleled accuracy and linearity of infusion even
• Ultrasonic Air-in-Line Detection and
at the lowest infusion rates to meet the standards of cumulative counter configurable to local
the most demanding specialties & indications. protocols.
BodyGuard constitutes a major advance in • Free-Flow Protection and anti-reflux in
ambulatory and bed - side pump technology all consumables.
incorporating active & passive safety features
which can be configured to fit local practice and • 3 Level Access Security Codes prevents
unauthorised personnel changing settings.
locked to prevent change by unauthorized
personnel. • Connectivity to PC enabling 24 Hour
Patient History (including charts) & 1000
These features include security access codes anti - Event Log download plus configuration
bolus system, free - flow protection in all of protocols and settings by computer.
consumables, downloadable patient and event
history, adjustable air - in - line detection • MediGuard software to reduce human
BodyGuard software can be adjusted to user needs, errors by setting limits appropriate to
including choice of language for information patients weight.
display, range of features and settings.
BodyGuard 121 Twins
Ambulatory Dual Channel
Infusion Pump

Specifications

Pumping Mechanism: Piston Pump

Total Infused Volume: 0.1 to 9999 ml

Flow Rate: 0.1 - 1200 ml/hr in 0.1ml increments / 1ml/hr increments

Accuracy: ± 3 %.

KVO rate: 1.0 to 5.0 ml/hr in 1 ml increments

Air Sensor: Ultrasonic, adjustable (0.1 -1.0ml) air bubble size

Maximum Pressure: 10 psi (adjustable - high 10 psi / normal 7.5 psi /low 5 psi)

Power Supply: 110-240V AC, 50/60 Hz. (20W/0.12A)

Battery: Li-ion 7.2V, 1450mA. (Rechargeable)

Battery life: 175h @ 1.0ml/h, 67h @ 5.0ml/h, 35h @ 15ml/h

Battery Charging: Automatic when clicked into the Charger Connected to an AC


power source. Six hours required to charge a fully depleted battery.

Alarms: End Program, Low Battery, End Battery, Lock Mode,


Air-in-line, Down Occlusion, Door Open, Pump Unattended,
System Malfunction (followed by error code), Missing Key

Dimensions: 146mm x 84mm x 40mm. (H/W/D)

Weight: 450 grms

Manufactured by: Caesarea Medical Electronics Limited


Address: Staufenburgstr. 23, Lichtenstein
POB 1248, Lichtenstein 72805, Germany.

©2002 by Caesarea Medical Electronics Ltd. All rights reserved.


BodyGuard is a registered trademark of C.M.E. Ltd.
www.cme-infusion.com

Free toll Tel no.: 1-800-323-575-00

FDA Approved 510K NO K31749