101-009   Engine Shutdown 
 
 

General Information 

Before engine shutdown,   
the load should be 
reduced slowly over a 
period of approximately 
120 seconds. The load 
reduction is fully 
automatic when operated 
in Automatic Mode (OEM 
control panel set to 
Automatic mode). When 
operated in Manual 
Mode (OEM control 
panel set to Manual   
mode), the base load 
should be manually 
reduced to the minimum 
load setting (20%) via the 
base load control 
function within the OEM 
control panel, before 
opening the Generator 
Set Circuit Breaker using 
the manual breaker 
control function on the 
OEM control panel. 
 
Run the engine at low idle for   
3 to 5 minutes before shutting 
it off after a full-load operation. 
This allows adequate cool 
down of pistons, cylinders, 
bearings, and turbocharger 
components. 

Set the OEM control panel to 
OFF or STOP. If the engine 
does not shut down, refer to 
Troubleshooting Symptom 
(Section TS) in appropriate   
Operation and Maintenance 

mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-101-009-om-gdng.html 12/07/2020
Engine Shutdown Page 2 of 2

manual. 

NOTE: For engines 
equipped with an electronic 
control module (ECM) 
ensure the keyswitch is 
turned off for a minimum of 
60 seconds prior to 
disconnecting the 
continuous (unswitched) 
battery power supply. If the 
unswitched battery power 
supply is disconnected in 
less than 70 seconds after 
the keyswitch is turned off 
active fault codes and 
incorrect ECM information 
can occur.  

 CAUTION   
 
Failure to follow the correct 
shutdown procedure may 
result in damage to the 
turbocharger and shorten 
the turbocharger life. 

 
 