Beruflich Dokumente
Kultur Dokumente
A brand of
installed.
DIRAK GmbH
Königsfelder Straße 1
D-58256 Ennepetal
+49 (0) 2333 837-0
eline@dirak.de
elinebydirak.com
MLR
Mechatronic Locks for Racks
MLE
Mechatronic Locks for Enclosures
MLI
Mechatronic Locks for Industrial Applications
MLU
Mechatronic Locks for Universal Applications
MLM
Mechatronic Locks Management
62 2.441 30 30 1.183 62 30 1.183
30 30 30 30 1.183
40 1.575 8 27 40 271.063 40 8 271.063
MLR
408 8 27 27 8 27 40 34 1.339 271.063
Mechatronic Locks 0.315
for Racks
25
25 25 25
25 250.98425 25
50 1.969
50
77
0.1
50
4 ,5
4 ,5
50
450
50
50
4 ,5
4 ,5
4 ,5
,5
308 12.126
308
308
308
155 6.102
100 3.937
70 2.756
50 1.969
100
155
100
100
100
100
100
100
70
50
70
50
70
50
70
50
50
70
5 5 5 5 5 5
0.197
36 36 1.41736 36 36 36
60 2.362
60
MLR5000 KP MLR3000 KP
LED handle status ó
MULTI-POINT CAMS ROD LATCH OFFSET Offset
Keypad with LED keypad status ó The swinghandle can be In the rod latch system, The revolving pull handle
LED temperature status ó combined with a multi- the revolving pull handle drives the locking slide
LED sabotage alarm/ready for opening ó point cam. Optionally, drives the mechanism in on the side of the handle.
Conditional Relay ó a round rod system can the rod latch housing. Flat The laterally operated rod
Reader 125 kHz ó contribute to multi-point rods run vertically to the system is typical for the
Reader 13,56 MHz ó locking. doorframe. offset version.
Relay output (via screw terminal) 2,5 mm², can be connected from the plug-in side ó
Door contact input (screw terminal on plug-in side), 2,5 mm², terminal 1 and 2 ó
Interface Ethernet RS 485
SCOPE OF SUPPLY
Storage space for transponder 1.000
Storage space PIN 1.000 Swinghandle black plastic recess, zinc diecast
Storage for 500 events and 30 time profiles ó Ready for operation handle mat chromeplated
Configurable LED
ntegrated real-time clock with buffering up to 60 min. at 25 °C ó
Unauthorized Access / “Blocking Period”
Temperature range –20 °C … +70 °C ó Control unit plastic enclosure, can be fixed with
Sheet thickness plus powder-coating 1,5 – 2 mm Alarm screws or selfadhesive pad
Torque mechanism screw connection (top) 1,0/1,2 Nm Handle open Connection Cable 8-pin; 350 cm; UL-approved,
Torque cap screw connection (bottom) 0,4 Nm Door open 26 AWG stranded wire; RJ45 connector molded
Power supply ±10 % (DC) / standby current (DC) / max. current consumption (DC) 12 V / 45 mA / 440 mA onto one end; crimped JST ZHR-8 connector on
Access authorized
Stand-alone possible other end
Illuminated info field – “Green Period”
Power over Ethernet capable ó — An external power unit is not included in the scope
Temperature okay
of supply, but can be ordered as an accessory.
Temperature alarm
We offer a variety of mechanical adapters for all major rack manufacturers or we can design a customized solution.
30 30 30
408 8 27 27 8 27
25 250.98425 25 25 25
25 25
50 1.969
77
0.1
450
50
50
4 ,5
4 ,5
4 ,5
,5
50
50
50
5 5
50
4, 4,
100 3.937
155 6.102
70 2.756
50 1.969
100
100
100
155
9.921
70
50
70
50
50
70
100
100
100
70
50
100
70
50
5 5 5 5 5 5
252
252
252
252
0.197
36 36 1.41736 36 36 36
60 2.362
60
MLR5000 MLR3000 MLR1000 MULTI-POINT CAMS ROD LATCH OFFSET Offset
LED handle status ó ó The swinghandle can be In the rod latch system, The revolving pull handle
LED temperature status ó — combined with a multi- the revolving pull handle drives the locking slide
LED sabotage alarm ó — point cam. Optionally, drives the mechanism in on the side of the handle.
Conditional Relay ó — a round rod system can the rod latch housing. Flat The laterally operated rod
Reader 125 kHz ó — contribute to multi-point rods run vertically to the system is typical for the
Reader 13,56 MHz ó — locking. doorframe. offset version.
Relay output (via screw terminal) 2,5 mm², can be connected from the plug-in side ó —
Door contact input (screw terminal on plug-in side), 2,5 mm², terminal 1 and 2 ó —
Interface Ethernet RS 485 —
SCOPE OF SUPPLY
Storage space for transponder 2.000 —
Stand-alone possible — Swinghandle black plastic recess, zinc diecast
Storage for 500 events and 30 time profiles ó — Ready for operation
handle mat chromeplated
Integrated real-time clock with buffering up to 60 min. at 25 °C ó — Unauthorized Access / “Blocking Period”
Temperature range –20 °C … +70 °C ó ó Control unit plastic enclosure, can be fixed with
Alarm
Sheet thickness plus powder-coating 1,5 –2 mm screws or selfadhesive pad
Handle open
Torque mechanism screw connection (top) 1,0 /1,2 Nm Connection Cable 8-pin; 350 cm; UL-approved,
Torque cap screw connection (bottom) 0,4 Nm Door open
26 AWG stranded wire; RJ45 connector molded
Power supply ±10 % (DC) / standby current (DC) / max. current consumption (DC) 12 V / 40 mA / 440 mA Access authorized onto one end; crimped JST ZHR-8 connector on
Illuminated info field Color configurable other end
“Green Period”
Power over Ethernet capable ó — —
Temperature okay An external power unit is not included in the scope
of supply, but can be ordered as an accessory.
Temperature alarm
We offer a variety of mechanical adapters for all major rack manufacturers or we can design a customized solution.
MLR Mechatronic Locks
for Racks
MLR5000 (KP)
ETHERNET
GND
N/O
N/C
DOOR
COMMON
CAT CONTROL LINE
•••
CAT •••
DOOR CONTACT
MLR3000 (KP)
•••
CN
SWITCH READER MLR server racks (central server rack
GATEWAY
MLM
CAT
Administration
Suite LAN OUTP. CONF. HANDLE structure). With just one IP address
MAX.
it is possible to manage up to 32
GND
N/O
N/C
DOOR
COMMON
32 SYSTEMS CONTROL LINE
•••
CAT
CN CN
swinghandles in one E-LINE by
DIRAK gateway.
DOOR CONTACT
MLR1000
+
Pink
Opening: 12–24 V DC –
Dark Blue
Yellow
Handle status Green
Red
N/O
N/C
DOOR
COMMON
YELLOW STATUS
GREEN STATUS
CONTROL LINE LAN is used here. This system
is therefore quick and easy to
install.
35
1,5 15,5 35
35 1.378
1,5
35
15,5 1,5
1,5 15,5
15,5
0.059 0.610 CONTROL LINE
09
0.2
,3
Ø5, 5
3.406
1.969
3.543
50 1.969
ALTERNATIVELY:
0.551
86,5
86,5
86,5
86,5
50
90
50
50
90
90
50
50
50
50
14
14
14
14
YELLOW
GREEN
WHITE
BROWN
Stand-alone possible
Relay output and door contact input plastic enclosure, can be fixed
ready to open
Standby current (DC) 40 mA with screws or selfadhesive pad
Max. current consumption (DC), RJ 12/Lock 1.4 A opened
Connection cable
Max. current consumption (when engaging the coupling) Alarm/ 7 m control line, tool-free
3.0 A (DC), terminal 10–11
no authorized transponder configurable RJ 45 connector
Multicolored status LED can be deactivated (control line can be indepen-
Material Zinc diecast powder-coated and plastic dently shortened)
Temperature range – 20 °C ... +70 °C
Integrated real-time clock with buffering up to 60 min. at 25 °C
Watertight and dust-tight IP65
Nominal input voltage 12 V / 24 V / 48 V (DC) ±10 % 120 mA,
(depending on lock connected)
Power over Ethernet capable
MLE Mechatronic Locks
for Enclosures
MLE1102
1.575 1.024
positions (open/closed) this
2.244
can enable further evaluations.
- BROWN SOLENOID Whilst the management
+ ORANGE SOLENOID
0.886 BLACK STATUS systems usually only display
22,5 RED STATUS
whether the cabinet door is
oder
or
20 0.787
“open” or “closed”, with the
or MLE1102 you have further
46 1.811
possibilities.
4.134
7.087
105
46 1.811
MLE1102 SCOPE OF
SUPPLY
LED handle status on request
Closing “Or” swing handle
Power supply (DC) 12/24/48 V + 10 % 250 mA/140 mA/100 mA zinc diecast
Opening Key Cylinder
Status request Proximity switch (potential-free)
Color light gray/black, powder-coated
(customer-specific colors on request)
Wall/sheet thickness (plus powder-coating) up to 10 mm
For electronic opening power supply established
One suitable cylinder
Watertight and dust-tight IP65
Vandalism class RC2
MLE Mechatronic Locks
for Enclosures
MLE1200
WHITE SOLENOID
BROWN SOLENOID
GREEN HANDLE CONTACT
YELLOW HANDLE CONTACT
monitoring system. For
evaluation purposes, use
the status issued by the
swinghandle (open or
closed).
+
–
30,5 1.201 30,5 1.220
oder
or
Simply integrate the MLE
20 0.787
2100/2200 in an existing
or
46 1.811
management system.
Connect the positive
105 4.134
6.555
6.535
opening function of
166
166
+
–
closed) is signaled by
means of data transfer
and enables further
22,5 22,5
evaluations. In this way
SCOPE OF
the MLE 2100/2200
oder 20 oder 20 MLE2100 MLE1200 MLE2200
SUPPLY
Closing “And” “Or” “And” expands the status
LED handle status ó – – swing handle
Power supply (DC) 24 V ±10 % / 120 mA 48 V ±10 % / 120 mA 24 V ±10 % / 120 mA zinc diecast control of conventional
Opening – Key / Cylinder Key / Cylinder
for electronic opening Power supply interrupted established interrupted management systems.
105
105
46
46
MLI Mechatronic Locks
for Industrial Applications
MLI1101
21210.827
a fault is present or sabotage
21
25 0.984 34341.339 34 12,5
34 34 12,5
341.339 12,5 0.492
25 25 took place.
50 1.969
50
50
50 1.969
157 6.181
157
100
100
157
0,8 0,8
0,8
0.031
50 1.969
6,3
6,3
6,3
MLU Mechatronic Locks
124
124
for Universal Applications 40 40 30 40 30 30
124
75
75
75
25 25 2
12
12
12
50
50
50
ØØ10
10
Locking stub
137,8
137,8
137,8
Ø10
0.394
18
18
0.709
18
MM66 7,9
7,9 0.311
M6 0.236 7,9
40 1.575 40 30 30 1.181
30
28,8 2128,8 28,8 21 21
25 25 0.827
25 0.984
3 3 3
0.248
0.248
0.118
50 1.969
6,3
6,3
6,3
6,3
50
137,8 5.425
50
4.882
137,8
124
124
124
2.953
2.953
75
75
75
6,3 0.248
21
0.472
12
12
12
28,8 28,8 21 21 Ø10 Ø10 Ø10
18
18
18
MLU5000 MLU3000 SCOPE OF SUPPLY MLU1000 SCOPE OF SUPPLY
124
6,3
124
Relay output (via screw terminal) 2,5 mm², can be connected from the plug-in side Relay contact: 12 V, 3 A, 60 W, 120 VA, terminals 3–5
75
140/90/50 mA
Ø10 Door contact input ó AWG 26, one end with
Integrated real-time clock with buffering up to 60 min. at 25 °C ó molded RJ45 connector, locking pressure ca. 200 kg
Temperature range –20 °C … +70 °C ó one end with crimped JST Temperature okay
Storage for 500 events and 30 time profiles ó ZH connector ZHR-8
Temperature alarm
Standby current (DC) 40 mA
7,9
Max. current consumption (DC), RJ 12/Lock 1,5 A
Max. current consumption (DC) on relay terminals 3 A (terminals 10 –11)
12
12
Ø10 Ø10
18
18
M6 M67,9 7,9
MLU Mechatronic Locks
for Universal Applications
MLU5000
LAN LOCK
Communication with the MLU
READER MLU
SWITCH 5000 takes place via the TCP/IP
CAT ANTENNA
protocol. Each reader receives
MLM
Administration
Suite
ETHERNET
N/O
N/C
DOOR
COMMON
YELLOW STATUS
GREEN STATUS
CAT CONTROL LINE a static IP address and is
reachable in the network at all
times. No separate bus system
•••
CN
MLU3000
•••
CN LOCK
SWITCH READER MLU
GATEWAY
3000 takes place via the ELINE
MLM
Administration CAT
LAN OUTP. CONF. ANTENNA
Suite by DIRAK-Gateway. It forms an
MAX.
N/O
N/C
DOOR
COMMON
YELLOW STATUS
GREEN STATUS
32 SYSTEMS CONTROL LINE interface between the RS485
•••
CAT
MLM
Administration
Suite
CAT
RS 485 BUS
•••
TCP/IP
•••
SWITCH SWITCH
•••
CAT
MLM
Administration
• • • • • • • • • • • • • • • CAT
Suite