Beruflich Dokumente
Kultur Dokumente
Test/Witness Engineer :
This report details the results of the testing carried out on one sample. The results contained in
this test report do not relate to other samples of the same product. The manufacturer should
ensure that all products in series production are in conformity with the product sample detailed
in the report.
TB-RF-075-1.0
1 A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang,
Bao’an, Shenzhen, Guangdong, China
Tel: +86 75526509301 Fax: +86 75526509195
Report No.: TB-EMC150788
Page: 2 of 24
TABLE OF CONTENTS
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 3 of 24
1. General Information
1.1. Client Information
Applicant : Foshan Kuroku Technology Co., Ltd
Address : Floor 2, No.7 Building, Xiadong Sanzhou Guicheng, Nanhai
District, Foshan Guangdong, China.
Manufacturer : Foshan Kuroku Technology Co., Ltd
Address : Floor 2, No.7 Building, Xiadong Sanzhou Guicheng, Nanhai
District, Foshan Guangdong, China.
DC Power EUT
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 4 of 24
Criterion B: After the test, the equipment shall continue to operate as intended without
operator intervention. No degradation of performance or loss of function is allowed, after
the application of the phenomena below a performance level specified by the
manufacturer, when the equipment is used as intended.
CNAS (L5813)
The Laboratory has been accredited by CNAS to ISO/IEC 17025: 2005 General
Requirements for the Competence of Testing and Calibration Laboratories for the
competence in the field of testing. And the Registration No.: CNAS L5813.
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 5 of 24
Conducted Disturbance at
EN55015:2013+A1:2015 N/A
Mains Terminals
Magnetic Emission EN55015:2013+A1:2015 Pass
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 6 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 7 of 24
The frequency range from 9KHz to 30MHz is investigated. The receiver is measured with
the quasi-peak detector. For frequency band 9KHz to 150KHz, the bandwidth of the field
strength meter is set at 200Hz. For frequency band 150KHz to 30MHz, the bandwidth is
set at 9KHz.
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 8 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 9 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 10 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 11 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 12 of 24
The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the
test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of
the antenna are set to make the measurement.
The initial step in collecting radiated emission data is a spectrum analyzer peak detector
mode pre-scanning the measurement frequency range. Significant peaks are then marked
and then Quasi Peak detector mode re-measured.
If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit,
the EUT shall be deemed to meet QP Limits and then no additional QP Mode
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 13 of 24
measurement performed.
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 14 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 15 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 16 of 24
1 ±2 ±2
2 ±4 ±4
3 ±6 ±8
4 ±8 ±15
X Special Special
re-triggered for a new single discharge and repeated 10 times for each pre-selected test
point. This procedure shall be repeated until all the air discharge completed.
6.3.2. Contact Discharge:
All the procedure shall be same as air discharge. Except that the tip of the
discharge electrode shall touch the EUT before the discharge switch is operated.
6.3.3. Indirect discharge for horizontal coupling plane
At least 10 single discharges (in the most sensitive polarity) shall be applied at the front
edge of each HCP opposite the center point of each unit (if applicable) of the EUT and
0.1m from the front of the EUT. The long axis of the discharge electrode shall be in the
plane of the HCP and perpendicular to its front edge during the discharge.
6.3.4. Indirect discharge for vertical coupling plane
At least 10 single discharges (in the most sensitive polarity) shall be applied to the center
of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X
0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT.
Discharges shall be applied to the coupling plane, with this plane in sufficient different
positions that the four faces of the EUT are completely illuminated.
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 18 of 24
Criterion: B
Slots A PASS
HCP C PASS
Remark:
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 19 of 24
1 1
2 3
3 10
X Special
In order to judge the EUT performance, a camera is used to monitor its screen.
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 20 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 21 of 24
Criterion: A
Modulation: Unmodulated
80~1000MHz
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 22 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 23 of 24
TB-RF-075-1.0
Report No.: TB-EMC150788
Page: 24 of 24
TB-RF-075-1.0