Sie sind auf Seite 1von 3

Job No.

JA 1210
Painting Surface External
Coat System

Paint Vendor Sigma (System - H)

Primer Intermediate Coat Top Coat


%Volume solid, VS 57 %Volume solid, VS %Volume solid, VS
% Wastage 75 % Wastage % Wastage
Loss Factor 0.57 Loss Factor 1.00 Loss Factor 1.00
Thinner Percentage 10 Thinner Percentage 0 Thinner Percentage 0

Dry Film Thickness


Area to be painted Paint Required* Paint Qty to be ordered Unit Rate Price
Sr.No. Coats Detail Product Name Colour (DFT)
(Microns) (m ) 2
(ltr) (ltr) (SAR/ltr) SAR
1- Primer Sigma cover 280 Light Gray 75 1940 446.7 450 considering 75% wastage
2- Intermediate #DIV/0! 16.5 0
3- Top #DIV/0! 17 0
3- Thinner (For Primer) Thinner 91-92 - - - 45.0 50 8 400
4- Thinner (For Intermediate) - - - - - - + ###
5- Thinner (For Top Coat) - - - - - - 8 ###
Total ###
Paint Vendor Sigma (System - N)

Primer Intermediate Coat Top Coat


%Volume solid, VS 45 %Volume solid, VS 45 %Volume solid, VS
% Wastage 75 % Wastage 75 % Wastage
Loss Factor 0.57 Loss Factor 0.57 Loss Factor 1.00
Thinner Percentage 0 Thinner Percentage 10 Thinner Percentage 10

Dry Film Thickness


Area to be painted Paint Required* Paint Qty to be ordered Unit Rate Price
Sr.No. Coats Detail Product Name Colour (DFT)
(Microns) (m2) (ltr) (ltr) (SAR/ltr) SAR
1- Primer Sigma Therm 540 Aluminium (RAL 90 30 4420 516 520 14.5 7540
2- Intermediate Sigma Therm 540 Aluminium (RAL 90 30 4420 516 520 16.5 8580
3- Top #DIV/0! 17 0
3- Thinner (For Primer) - - - 8 0
4- Thinner (For Intermediate) - - - 8 0
5- Thinner (For Top Coat) - - - 0.0 - 8 ###

*Paint required with loss = DFT X Area (m2)


10 x %VS x Loss Factor

Paint Vendor Sigma (System - C)

Primer Intermediate Coat Top Coat


%Volume solid, VS 65 %Volume solid, VS 45 %Volume solid, VS 45
% Wastage 75 % Wastage 75 % Wastage 75
Loss Factor 0.57 Loss Factor 0.57 Loss Factor 0.57
Thinner Percentage 10 Thinner Percentage 0 Thinner Percentage 0

Dry Film Thickness


Area to be painted Paint Required* Paint Qty to be ordered Unit Rate Price
Sr.No. Coats Detail Product Name Colour (DFT)
(Microns) (m2) (ltr) (ltr) (SAR/ltr) SAR
1- Primer Sigma Zinc 158 Greenish Gray 50 300 40 40 14.5 580
2- Intermediate Sigma therm 540 Aluminium (RAL 90 25 300 29 30 16.5 495
3- Top Sigma therm 540 Aluminium (RAL 90 25 300 29 30 17 510
3- Thinner (For Primer) thinner 90-53 - - - 4.0 5 8 40
4- Thinner (For Intermediate) - - - 8 0
5- Thinner (For Top Coat) - - - 0.0 - 8 ###
Job No. JA 1379
Painting Surface Internal
Coat System APCS-2F

Paint Vendor Jotun

Primer Intermediate Coat Top Coat


%Volume solid, VS 96 %Volume solid, VS 72 %Volume solid, VS 96
% Wastage 50 % Wastage 50 % Wastage 50
Loss Factor 0.67 Loss Factor 0.67 Loss Factor 0.67
Thinner Percentage 10 Thinner Percentage 10 Thinner Percentage 10

Dry Film Thickness


Area to be painted Paint Required* Paint Qty to be ordered Unit Rate Price
Sr.No. Coats Detail Product Name Colour (DFT)
(Microns) (m )
2
(ltr) (ltr) (SAR/ltr) SAR
1- Primer Sipoxy Guard 270 Manila 0.0 40 26.5 1060
2- Intermediate Sipoxy Guard 270 Off White 0.0 40 26.5 1060
3- Top Baltoflake , white white strene 1000 0.3 0.5 3 26.5 79.5
3- Thinner (For Primer) Thinner 740 - - - 4.0 5 8 40
4- Thinner (For Intermediate) Thinner 740 - - - 4.0 5 8 40
5- Thinner (For Top Coat) Thinner 740 - - - 0.3 5 8 40
Total 2320

*Paint required with loss = DFT X Area (m2)


10 x %VS x Loss Factor
Job No. JA 1210
Painting Surface External Internal
APCS System 0 -

Cost Comparison

Sr. No. Vendor Name External Paint Internal Paint Total (SAR)
1 Ameron 2000 4320 6320
2 Jotun 1670 2910 5000
3 Hempel 1825 2865 4690
4 Sigma 1560 3100 4660
5 Sigma (System - H) #VALUE! 2319.5 #VALUE!
6 International 0 0 25000

Selected Vendor #VALUE!

Das könnte Ihnen auch gefallen