FUNDAMENTALS OF OPHTHALMOSCOPY

FOR MEDICAL STUDENTS

By: M. Al Fayez, MD, FRCS

Ophthalmoscopy is an essential skill for all clinicians. Like other clinical skills, mastery is
conditional on proper technique and practice, practice, practice. If you learn the proper
techniques early in your education, you can become a skilled examiner of the ocular fundus
by the time you earn your MD. Following the outline below these pages discuss the basics
required to develop a proper technique for fundus examination using direct ophthalmoscopy.

I. Instruments

II. To Dilate or Not To Dilate

III. Preparation

IV. Instrument Settings

V. Orientation and Landmarks

VI. What Am I Seeing?

VII. Precautions and Comfort Considerations

VIII. Practical Applications and Limitations

I. Instruments

The standard instrument for clinical examination of the ocular fundus has been the “direct”
ophthalmoscope for many years. The most common model has been the standard head made
by Welch-Allyn or Keeler. This is a monocular viewer with various settings that allow
focusing and adjustment of the light source to accommodate the viewer and to evaluate
various features of the fundus.

Recently, Welch Allyn introduced the Panoptic ophthalmoscope and Keeler introduced the
Wide View Twin Mag, two radically different instruments that provide a much larger view of
the fundus (nearly 5x), and facilitate viewing even through an undilated pupil. They are
monocular instruments that provide “direct” visualization of the fundus with a variety of
settings and attachments for ocular examinations.

1
WA Head PanOptic Head Standard View Panoptic View

II. To Dilate or Not To Dilate

It is obvious that the best view of the fundus is obtained through a dilated pupil. This is
especially true of older patients. Miosis occurs as part of the normal aging process, and
additional difficulties often result from deterioration of the media due to cataracts, etc.
Use of short acting dilating drops can increase the area of the fundus examined. The most
effective combination is tropicamide 1% and phenylepherine 2.5% as they act on different
iris muscles. If you can only use one dilating drop instill tropamide which dilates the pupil
more efficiently than phenylepherine.

Note, however, that even with dilation, only approximately one-third of the fundus is visible
with a direct ophthalmoscope. Fortunately, the area most visible is the posterior pole where
the ocular findings of many systemic diseases, such as diabetes and hypertension are located.
This includes the disk and the macula, but if peripheral disease such as retinal tears or
detachment is suspected, other techniques like indirect ophthalmoscopy must be used.

2
III. Preparation

Paying attention to several details before you begin can greatly enhance the success of your
viewing efforts. If possible, dim the room lights to avoid light distractions and maintain your
attention to details. The patient should be seated comfortably (or lying supine in bed) to
minimize head movement. Ask the patient to look straight ahead at a distant object. (If
dilating drops is not used and the patient looks at the light or a near object, the pupil will
constrict due to accommodation making examination difficult.). It is helpful to warn patients
that your head may block their fixation but not to move their eyes or head if you do.

The observer also should be stabilized in order to maintain the correct viewing angle and
distance from the eye. You may wish to place your free hand on the patient’s shoulder or
brow, but it is preferable to use the edge of the bed or the back of the chair.

IV. Instrument Settings

The ophthalmoscope should be prepared for the specific viewer and patient. Using the
standard head, set the diopter power to “0”, and follow the directions for the Panoptic or
Twin Mag to make it compatible with your refraction, if any. Both patient and observer
should remove their glasses, but contact lenses do not need to be removed.

Adjust the size of the incident light beam to approximate the size of the patient’s pupils. If the
size of the light source is much larger than the pupil, reflected rays may cause glare and
dazzle that interferes with detailed examination.

Turn on the light to approximately one-half the maximum intensity to begin, and then adjust
for optimum viewing when the fundus is in view. Do not use maximum intensity especially
when using instruments with halogen bulbs as the brightness can be uncomfortable for
patients, especially when viewing the macula.

V. Orientation and Landmarks

The optic disc is in the same location in everyone, and is easy to identify. Therefore, if you
can find the disc right away, it is usually easier to maintain your orientation and to adjust
your viewing angle to see other structures. Hold the ophthalmoscope vertically placing your
index finger on the edge of the lens dial so that you may change lenses easily if necessary.
Use your right eye to view the patient’s right eye, and your left for the patient’s left. (With
the PanOptic or Wide View Twin Mag, it is possible to use the same eye to view both patient
eyes if necessary but it is not recommended).

The observer directs the light from the ophthalmoscope at the pupil at an angle of 15-20
degrees temporally from the patient’s line of sight (visual axis), at a distance of
approximately 30cm from the patient’s eye. Aiming your ophthalmoscope at the pupil along
the axis of the white line in the following illustration, you should be able to see a red reflex in
the pupil (if you cannot find a red reflex, it may mean that a cataract or other obstruction
precludes fundus examination). Keeping the red reflex in your view, move closer until the
field of view fills your viewer (about 3-5cm from the eye with the standard ophthalmoscope)
where the optic disc should come into view. If it is not focused clearly, rotate lenses with

3
your index finger until the optic disc is as clearly visible as possible. The hyperopic eye
requires more plus lenses for clear focus of the fundus; the myopic eye requires minus lenses
for clear focus. Maintain this position as you slightly change the angle of the ophthalmoscope
head to examine other areas of the posterior pole.

This is the right eye illustrating the relationship of the macula


to the optic nerve. Note that to find the disk, the observer must
aim 15-20 degrees temporally from the patient’s line of sight.
For the left eye the observer moves to the patient’s left side.

If you do not see the outline of the disc with this technique, stop, move back 30 cm, and try
again, perhaps using a slightly different angle. While in the proper position, you may do a
brief search for the disc, but prolonged searching by following vessels, for example, is
usually unproductive. More importantly, patients become fatigued rather quickly from the
bright light and effort required for cooperation.

The most important skill to learn while practicing is to find the viewing angle necessary to
locate the optic disc with a minimum of effort. This ensures that that you will have a
cooperative, relaxed patient while you are visualizing the fundus, and your examination will
be spent on a productive evaluation.

VI. What Am I Seeing?

To ensure that a thorough examination of all pertinent areas is performed, it is useful to


develop a technique of examination that includes all areas to be examined and the specific
findings to note.

Beginning with the optic nerve head, since that should be the first target seen, adjusts the
focus on your ophthalmoscope to sharpen the view as much as possible. Note the color and
size of the disk, the sharpness of the disk margins, whether there is any edema or elevation,
the presence of hemorrhages, the size of the cup relative to the total disk size and the location
and caliber of the central retinal vessels.

Then follow each of the main arterial and venous branches into each of the four quadrants as
far as you can, again noting the caliber and color of the vessels, the appearance of any
pigmentary changes, and search for hemorrhages and exudates in each area. Move back to the
optic disc, and then temporally one and one-half disk diameters and you should be in the

4
central macula. You may also have the patient look at the light of the ophthalmoscope, which
will automatically place the macula in full view. Note the presence or absence of
hemorrhages and exudates, pigmentary clumping or absence, and any scars that may be
present. The red-free filter facilitates viewing of the centre of the macula.

If the patient presents with visual loss:


a. examine the disc for:
Swelling seen in: anterior ischemic optic neuropathy;
optic neuritis;
central retinal vein occlusion
b. examine the vessels for:
tortuosity and dilatation seen in central retinal vein occlusion;
narrowing of the vessels in central retinal artery occlusion
c. examine the retina for:
paleness in retinal artery occlusion;
hemorrhages in retinal vein occlusion; diabetic retinopathy.

To examine the mid-periphery, instruct the patient to look up for examination of the superior
retina, down for the inferior retina, temporally for the temporal retina and nasally for
examination of the nasal retina.

Note: in a patient complaining of sudden onset floaters, direct ophthalmoscope may not give
enough view to locate peripheral tear or hole and referral is recommended especially if you
notice any retinal hemorrhages.

Corneal reflection can interfere with fundal view. If this is troublesome, this can be overcome
with use of the polarized filter found in some ophthalmoscopes or using small aperture, but
this reduces the area of the fundus illuminated.

It is also helpful to note for future reference the clarity of your view and any observation
difficulties.

VII. Precautions and Comfort Considerations

A good examination of both fundi is an intensive task for both patient and observer. In
particular, the need to minimize movement while a bright light is shining into your eye can
cause considerable discomfort and it is considerate to allow the patient to occasionally rest
for 10-15 seconds or so during a prolonged examination. The need for close face-to-face
positioning is also discomfiting for some people. Usually about 10 seconds of observation is
about the maximum tolerated before a 10 second break is necessary. Using frequent breaks
during difficult examination allows a more detailed and thorough examination than
attempting to do everything with one viewing.

5
VIII. Practical Applications and Limitations

Examination of the ocular fundus is an important component of the clinical evaluation in


many diseases. It is essential in patients with diabetes mellitus, increased intracranial
pressure, and glaucoma, for example. However, it is important to understand its limitations
as well. Firstly, no stereopsis is possible since one can only obtain a monocular view.
Secondly, only the posterior, central fundus can be visualized, and the majority of the
peripheral fundus cannot be seen. Therefore, if a retinal tear or detachment is suspected, or if
there is a significant risk of retinoblastoma, or histoplasmosis, other techniques must be used.

Direct ophthalmoscopy is therefore a useful clinical tool which should be part of every
clinician’s examination routine. If utilized with skill, the practitioner can apply an important
diagnostic procedure to many of the diseases encountered in everyday practice. Knowing its
limitations can lead to appropriate referrals and more detailed evaluations.

Summary of technique:

1. To examine the right eye, sit or stand at the patient's right side.

2. Select "0" on the lens disc of the ophthalmoscope and start with the small aperture.

3. Hold the ophthalmoscope vertically in the right hand placing your right index finger on the
edge of the lens dial and place the ophthalmoscope in front of your right eye with the light
beam directed toward the patient.

4. Dim room lights. Instruct the patient to look straight ahead at a distant object.

5. Position the ophthalmoscope about 30 cm in front and slight to the right (15-20o) of the
patient and direct the light beam into the pupil and look for red reflex.

6. While the patient is fixating on the specified object, keep the red reflex in view and move
slowly toward the patient to get the optic disc into view. Rotate lenses if necessary until
the optic disc is as clearly visible as possible.

7. Examine the disc for clarity of outline, color, elevation and condition of the vessels.
Follow each vessel as far to the periphery as you can.
To locate the macula, focus on the disc, and then move the light approximately 2 disc
diameters temporally or have the patient look at the light of the ophthalmoscope.

8. Instruct the patient to look up, down, temporally and nasally for examination of the mid
peripheral retina.